A R C H I T E C T A N D FAC I L I T Y M A NAG E M E N T G U I D E
Entrance Systems for Health Care
“We are glad to have collaborated with Horton Automatics on the Southwest Washington Medical Center project. Not only did Horton meet stringent time and quality requirements, but they also implemented aesthetic and superior design that helped us differentiate our offering.� Leigh Sutphin, Principal NBBJ Client: Southwest Washington Medical Center, Vancouver, Washington (front cover photo)
Horton Entrance Systems for Health Care
The automatic choice for performance, convenience and peace of mind Hospitals and medical facilities have highly specialized access needs that drive some of the toughest building codes in North America. In these facilities, patients must be moved safely and often swiftly. Extra safeguards must be in place related to fire, smoke, wind, security and dozens of other critical considerations. Each facility must also host hundreds and even thousands of staff and visitors that pass through its doors each day. And it must do all of that efficiently in a 24/7 environment where the doors are never closed. That is health care today. And that is the world of Horton Automatics, the industry leader in door systems for hospitals, out-patient care clinics, nursing homes and other medical facilities.
2
Linear drive operators for sliding doors provide smooth, quiet operation and long life.
Smooth operators Preferred by architects for sleek aesthetics as well as durability, Horton operators are also the choice of facility
Simple adjustments for open-close speeds and actuation allow Horton swing door systems to adapt to your facility’s changing needs.
managers for low maintenance. Horton operators meet virtually any high or low energy access need.
Integrated solutions Combining Horton doors, controls, sensors and other access solutions throughout your facility will allow you to reduce maintenance worries and confusion. Consider an integrated Horton platform for ultimate continuity in facility design and management.
Specify Horton quality and reliability for your facility Among the top concerns of any health care facility manager is that a major entrance must be shut down and traffic re-routed. With Horton long life operators and high strength doors, you are choosing the most reliable door systems available. And if service is needed, Horton distributors are available to fix the problem promptly and keep your entrances functioning. Four #10-24 bolts secure corner block to horizontal rail Concave steel backup plate engineered as built-in self locking device for Grade 8 bolts Two Grade 8, 1/4-20 bolts secure corner block to vertical rail
Depend on Horton Professional Service Did you know that access issues and properly maintained door systems are now an important component of JCAHO* inspections? Ask your Horton Automatics distributor to provide regular preventive maintenance that will help assure swift approval on
Rugged Corner Block Construction – A Horton Exclusive! Heavy duty rail design with integral corner blocks adds structural integrity to all Horton door systems. Mortise-style corner block construction is far superior to mass produced through-bolt panels.
this portion of your accreditation.
* Joint Commission on Accreditation of Healthcare Organizations
3
Folding Doors Our folding doors are used for entrances as well as corridors that require a wide opening but cannot accept a conventional door because of space limitations.
Solutions designed to meet specific health care application requirements. Main Entrances Emergency Administration Intensive Care Cardiac Care Corridors Department Entrances Patient Rooms Pharmacy Admissions Accounts Payable Gift Shop
Swing Doors Designed for high traffic entrances providing convenience and reliability. The variety of header designs will satisfy any architectural requirement. 4
Revolving Doors
ICU/CCU Doors
Turn an ordinary entrance into an energyefficient vestibule system. This large diameter automatic revolving entrance easily accommodates mobile beds.
Patients are always in full view through the sliding glass door. The full breakaway feature allows for all panels to swing out of the way providing a large opening for swift removal of patients or equipment.
Add security plus convenience for drive-up or walk-up traffic in pharmacies, labs and other areas.
Sliding Doors
Fire Rated Doors
Our broad offering of sliding doors gives you a wide range of choices to meet your exacting requirements for size, color, and finish as well as function, grade of construction and security.
Offering the cleanest possible installation for fire rated applications in hospitals and other health care facilities requiring an automated fire door system. 5
Revolving Doors Grand® large diameter vestibule system Spacious compartments provide an elegant, energy-efficient entrance up to 16 ft. in overall diameter to manage high volume traffic needs including wheel chairs, walkers and even hospital stretchers.
“Horton Automatics consistently provides excellent preconstruction services. They understand our clients’ clinical
AutoFlow™ revolving systems rotate on approach, allow reduced speed setting for wheel chairs
requirements and their local distributor is also very responsive after installation to meet ongoing needs of the medical facilities we build.” Easily customized with special finishes, metal cladding, roof panel designs, Segmented® or round wall design as well as extended canopies
W
Chad R. Paasch Project Manager M. A. Mortenson Company Minneapolis, Minnesota www.mortenson.com
Glass ceilings and other custom touches add drama along with function.
Choice of 3- or 4-wing models, all with quiet, smooth operation and emergency egress panels that fold against the core
Wing
Constant seal helps control energy costs and eliminates drafts VistaScan™ electronic sensing system slows or stops the door E when objects are within 10" of the wings
Entry Outside Diameter
3-Wing
Voice messages announce door slowing, resuming speed and “please step forward” W ing
StormLock™ feature for high wind conditions W
Selection Guide Revolving & Sliding Door Applications Main Entrances
Type
Inside Diameter
Entry - 3 Wing
Entry - 4 Wing
Manual
6' to 8'
up to 3' 9 ⁄8"
up to 5' 7 15⁄16"
Security
6' to 7'
Automatic
9' to 10'
up to 4' 7 3⁄8"
up to 6' 9 5⁄16"
Outside Diameter
Segmented® Drum Entry - 3 Wing
Round Drum Entry - 3 Wing
11' to 12'
up to 5' 3⁄4"
up to 5' 2 3⁄16"
Outside Diameter
Entry - 3 Wing
Entry - 4 Wing
12' to 16'
up to 7' 3⁄8"
up to 10' 7"
1
Entry
Emergency MiniGrand®
—
up to 4' 8 13⁄16"
Administration Grand®
6
ARCHITECT TOOLS: Specs - www.hortondoors.com/Specifications/specifications.html CAD Files - www.hortondoors.com/Drawing/drawings.html
Outside Diameter
4-Wing
MiniGrand
®
The MiniGrand® offers the drum construction of a Grand® and the center shaft and door wing construction of an AutoFlow.®
Sliding Doors Profiler ® 2000 linear drive system These automatic sliding door systems are used in a wide range of health care applications, both interior and exterior. Custom-manufactured to your specifications, they are ADA compliant when properly specified and meet all construction, safety and security requirements.
ProSlide™ telescoping doors increase clear openings by more than 35% in limited spaces.
Elegant® all-glass system with heavy-duty belt drive system
Unlimited custom options for size and finish 7' to 9'
8' to 16'
High strength corner block construction ensures durability for trouble-free operation Door panels break out for emergency egress
Safety Beams
Optional MuntinBar
48"
Advanced microprocessor controls with built-in diagnostics
41 3/4" 24"
Dual safety beams for added threshold protection
Type SX-O (O-SX Reverse)
Selectable operating modes (day/night, hold open, one-way/two-way, partial opening, off)
Type O-SX-SX-O
Type 110 7' to 9'
8' to 14' 8
Safety Beams 48" 24" Type SX-O (O-SX Reverse)
Type O-SX-SX-O
Type 110 Optional Muntin Bar
Selection Guide
7' to 12'
Model
Type
Unit Width
Max Slide Opening
Breakout Opening Type 110 Type 310
Profiler ®
Single Slide Bi-part
7' to 9' 8' to 16'
3' to 4' 3' to 7'
3' 3 1⁄2" to 4' 31⁄2" 3' 7" to 7' 7"
6' 3" to 8' 3" 6' 9 1⁄2" to 14' 9 1⁄2"
Elegant ®
Single Slide Bi-part
6' to 8' 8' to 14'
2' 7 1⁄2" to 3' 8" 3' 4" to 6' 4"
2' 7 1⁄2" to 3' 8" 3' 4" to 6' 4”
— —
3' 7 ⁄2" to 6' 11 ⁄2" 3' 5 1⁄2" to 8' 9 1⁄2"
2' 1" to 3' 9" 2' 3" to 4' 11"
5' 9 ⁄2" to 10' 9 ⁄2" 5' 10 1⁄2" to 13' 10 1⁄2"
™
ProSlide Telescoping
Half Telescoping 7' to 12' Bi-part 8' to 16'
1
1
Safety Beams 48" 24"
1
1
Type SX-X-O (O-X-SX Reverse)
T
Type 110
O
7
ICU/CCU Sliding Doors Profiler-ICU® manual sliding door system Designed and built specifically for the critical care environment of ICU/CCU operations, these multi-function doors keep patients in full view when closed. The panels also slide as well as swing out to provide maximum clearance for beds and equipment.
Custom corner configuration shown
Choice of 2-, 3- or 4-panel designs as well as custom configurations Trackless design option for easier installation and a smooth floor surface Engineered with the same strong corner block design as our automatic door systems Recessed pull handles (standard), optional positive latch sets Selection Guide
Multi-access design allows clear monitoring of the room (top) plus sliding access (middle) as well as easy breakaway (bottom) to move patients.
Breakout Opening
Unit Width
Max Slide Opening
Type 110
Type 310
Single Slide
7' to 9'
3' to 4'
3' 3 1⁄2" to 4' 31⁄2"
6' 3" to 8' 3"
Bi-Part
8' to 16'
3' to 7'
3' 7" to 7' 7"
6' 9 1⁄2" to 12' 9 1⁄2"
7
Half-Telescoping 7' to 12'
4' 2" to 7' 6"
—
6' 1" to 11' 1" S
Up to 16'
7' to 9'
Manual Sliding Door Applications Intensive Care Cardiac Care
7' 2 1/2"
Optional Muntin Bar 41 3/4"
Type SX-O
(O-SX Reverse)
Type O-SX-SX-O
T
Type 110
Optional Muntin Bar 7' to 12'
Up to 16'
7' to 9'
Safety Beams 7' 2 1/2"
Optional Muntin Bar
48"
41 3/4"
8
Type SX-SO
Type 310
(SO-SX Reverse)
24" Type SO-SX-SX-SO
Type SX-SX-SO (SO-SX-SX Reverse)
Type 310
T
Profiler-ICU® Smoke Rated manual entrance solutions This door series provides flexible access to ICU/CCU patients along with smoke protection per UL 1784 and NFPA standard 105.
Note: Consult factory for newest configurations.
Modified door nosings, bottom rails and interlock seals exceeds smoke infiltration requirements of UL 1784.
Concealed high temperature weather-sweep and gasket design Positive latching handle Low-profile header for superior aesthetics Slide doors available in trackless or recessed track configurations SmokeSwing™ doors available in single, equal or unequal pair Selection Guide Single Slide
Unit Width
Max Slide Opening Type 110 & 310
Max Slide Opening Type 310 Trackless
Breakout Opening Type 110 Type 310
7' to 9'
3' to 4'
2' 9" to 3' 9"
3' 3 1⁄2" to 4' 31⁄2"
7' to 9'
U
6' 3" to 8' 3"
SmokeSwing™ Dimensions
Optional MuntinBar
7 ' 2 1 /2 "
Door Width
41 3/4"
Type SX-O
Single Equal Pair Unequal Pair
up to 48" up to 48" up to 48"
Unit width
(O-SX Reverse)
Unit height
Type 110
Optional MuntinBar
Type SX-SO
Type 310
7 ' 2 1 /2 "
7' to 9'
(SO-SX Reverse)
SmokeSwing™ Pair
ARCHITECT TOOLS: Specs - www.hortondoors.com/Specifications/specifications.html CAD Files - www.hortondoors.com/Drawing/drawings.html
9
Swing Doors HD-Swing® fire door package The all-in-one fire rated steel door system, Series 4900DP is a popular choice for hospital corridors where maximum clear opening is important. It is designed for high traffic use and complies with ANSI requirements for full energy (automatic) operation.
One-source solution incorporates a heavy duty operator concealed in the header.
Low-profile push bar protrudes only 1/2" for double egress doors in full open position, 1-1/16" for single or pairs of doors.
Series 4900DP packages include 18-gauge steel doors, frame, exit device and Series 4000 heavy-duty operator Push-N-Go® function activates the door when pushed, SoftTouch® reopens door if obstructed during closing
Steel Header
Wall
All hardware is factory installed for accurate alignment and time saving installation.
Operator
Selection Guide Door Width
Single Doors
3' 6" to 4' 3"
Pair of Doors
7' to 8' 6"
Swing Door Applications
Door Panel
Operator
Door Panel with Power Arm
Entrances Corridors Department Barriers Patient Rooms
10
Header– Vertical Section
ARCHITECT TOOLS: Specs - www.hortondoors.com/Specifications/specifications.html CAD Files - www.hortondoors.com/Drawing/drawings.html
Top View
EasyAccess® low energy handicap operator The Series 7000 operator is ideal for new or converted barrier-free openings per ANSI A117/156.19, ADA and local building codes. Standard features include: Automatic opening with button or push plate activation Easily adjustable opening and closing speeds Operator can be surface applied or overhead concealed Push-N-Go® feature, SoftTouch® reversing and obstruction sensing
HD-Swing® LE low energy heavy duty handicap operator Ideal for use with heavy doors, HD-Swing 4000LE series operators exceed handicap access requirements of ANSI A117/A156.19 as well as demands of high traffic hospital environments. Standard features include: Easy switching to full energy (automatic) operation Heavy duty for larger doors Choice of in-swing, out-swing, left or right handed operation
Folding Doors FoldingAccess® door system Emergency breakout Finger guard at all hinge points Accommodates 1-way or 2-way traffic Also available in manual opening styles for ICU applications
Folding Door Applications
Ideal for hospital corridors and vestibules that
3' 8" to 4'
6' to 8'
require wide openings in a limited space, these
Corridors
automatic folding doors incorporate Vista™
Opening Width
Single (2 door panels)
3' 5" to 4'
2' 811⁄16" to 3' 11⁄16"
Pair (4 door panels)
6' to 8'
4' 47⁄8" to 6' 47⁄8"
ICU
41 3/4"
Selection Guide Unit Width
Entrances
Optional MuntinBar
7' 6" Unit Ht.
sensing technology.
Fold Out-Type RHR (LHR Opposite) Fold In-Type RH (LH Opposite)
Fold Out-Type LHR-RHR Fold In-Type LH-RH
11
Security Windows Automatic and manual systems Fully assembled for easy installation Auto-close and reverse-on-contact functions Maximum security locks Sensor packages
Exterior view - automatic single slide, flush mount shown
Interior view with projecting panels and roof
Specified for hospital drive-through pharmacies Auxiliary pushbutton activation
plus labs, supply rooms and other secure interior areas, these windows can be equipped with transaction drawers, bullet resistant glass, a choice of counter tops and other custom features. WinScan™ photoelectric beam
HipScan™ activating system
Setting The Standards For Professional Installation And Service Horton Automatics brings you the professional support of factory-authorized distributors located throughout North America. Whether your application involves a single automatic door or a complete hospital access and security plan, you can expect all phases of the project to be handled professionally and responsively. Call your Horton Automatics distributor today for design, specification and and application assistance. Visit www.hortondoors.com to find the nearest distributor in your area.
Specify Horton and demand AAADM certified installation.
A Division of Overhead Door Corporation A Sanwa Shutter Company
Horton Automatics World Headquarters 4242 Baldwin Boulevard Corpus Christi, Texas 78405-3399 USA
Horton Automatics, Ltd. United Kingdom Unit A, Hortonwood 31 Telford, Shropshire, England TF1-7YZ
Phone: 800-531-3111, 361-888-5591 Fax: 361-888-6510 www.hortondoors.com
Phone: 01952 670169 Fax: 01952 670181
Form No. HC1000
©2007 Horton Automatics
Printed in U.S.A.