Panasonic-Automotive Relays-CQ

Page 1

CQ 1 FORM C AUTOMOTIVE SILENT RELAY

CQ RELAYS

FEATURES 17.0 .669

• Silent Noise has been reduced by approximately 20 dB, using our own silencing design. • Less space required Measuring only 17(L)×13(W)mm (.669(L)×.512(W) inches), this product ranks first among automotive quiet relays in terms of saving space. • Sealed construction

13.0 .512 16.6 .654

mm inch

• Next-generation standard terminal pitch employed The terminal array used is identical to that used in JJM relays. 2.5 .098

10.2 .400

10 .393

SPECIFICATIONS Contact

Characteristics

Arrangement Contact material Initial contact resistance (By voltage drop 6 V DC 1A) Contact voltage drop Nominal switching capacity

Rating

Expected life (min. operations)

Max. carrying current

Min. switching capacity#1 Mechanical (at 120 cpm) Resistive load Electrical Motor load

1 Form C Silver alloy Max. 100 mΩ Max. 0.2V (at 10 A) N.O.: 20 A 14 V DC N.C.: 10 A 14 V DC 35 A for 2 minutes, 25 A for 1 hour (12 V, at 20°C 68°F) 30 A for 2 minutes, 20 A for 1 hour (12 V, at 85°C 185°F) 1 A 12 V DC Min. 107 Min.105*1 Min. 3×105*2

Coil Nominal operating power

640 mW

#1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.

Max. operating speed (at nominal switching capacity)

6 cpm Min. 100 MΩ (at 500 V DC)

Initial insulation resistance*3 Initial Between open contacts breakdown Between contacts and coil voltage*4 Operate time*5 (at nominal voltage)(at 20°C68°F) Release time*5 (at nominal voltage)(at 20°C68°F) Functional*6 Shock resistance Destructive*7 Functional*8 Vibration resistance Destructive*9 Conditions for operation, transport and storage*10 (Not freezing and condensing at low temperature) Mass

Ambient temperature Humidity

500 Vrms for 1 min. 500 Vrms for 1 min. Max. 10 ms (initial) Max. 10 ms (initial) Min. 100 m/s2 {10G} Min. 1,000 m/s2 {100G} 10 Hz to 100 Hz, Min. 44.1 m/s2 {4.5G} 10 Hz to 500 Hz, Min. 44.1 m/s2 {4.5G} –40°C to +85°C –40°F to +185°F 5% R.H. to 85% R.H. Approx. 6.5g .23 oz

Remarks *1 At nominal switching capacity, operating frequency: 1s ON, 9s OFF *2 N.O.: at 5 A (steady), 30 A (inrush)/N.C.: at 20 A (brake) 14 V DC, operating frequency: 1s ON, 2s OFF *3 Measurement at same location as “Initial breakdown voltage” section *4 Detection current: 10mA *5 Excluding contact bounce time *6 Half-wave pulse of sine wave: 11ms; detection: 10µs *7 Half-wave pulse of sine wave: 6ms *8 Detection time: 10µs

TYPICAL APPLICATIONS • Intermittent wiper • Cruise control • Power windows • Auto door lock • Car stereo • Car air-conditioner • Electrically powered seats • Electrically powered sunroof, etc.

*9 Time of vibration for each direction; X, Y, direction: 2 hours Y X Z direction: 4 hours Z

*10 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT

ORDERING INFORMATION Ex. CQ

1

12 V

Contact arrangement

Coil voltage(DC)

1 Form C

12 V

Standard packing: Carton(tube package) 40pcs. Case: 800pcs.

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.


CQ TYPES AND COIL DATA (at 20°C 68°F) Part No.

Nominal voltage, V DC

Pick-up voltage, V DC (Initial)*

CQ1-12V

12

Max. 7.2

Drop-out voltage, V DC (Initial) Min. 1.0

Coil resistance, Ω 225±10%

Nominal operating current, mA 53.3±10%

Nominal operating power, mW

Usable voltage range, V DC

640

10 to 16

* Other pick-up voltage types are also available. Please contact us for details.

DIMENSIONS

mm inch 17.0 .669

13.0 .512

PC board pattern (Bottom view) 5-1.5 +0.1 0 dia 5-.059 +.004 0 dia

16.6 .654

10.0 .394

Max. 1.0 .039

0.4 .016

3.5 .138

10.2 .402

2.5 .098

*A

5-0.25 .010

5-1.2 Pre-soldering .047

Tolerance: ±0.1 ±.004 Schematic (Bottom view)

10.0 .394

1.5 .059 2.5 .098

10.2 .394

NO

Dimension: Tolerance Max. 1mm .039 inch: ±0.1 ±.004 1 to 3mm .039 to .118 inch: ±0.2 ±.008 Min. 3mm .118 inch: ±0.3 ±.012

COM COIL NC

* Dimensions (thickness and width) of terminal specified in this catalog is measured before pre-soldering. Intervals between terminals is measured at A surface level.

EXAMPLE OF CIRCUIT Control circuit for intermittent wiper motor

NO COM

12 VDC

NC

M

M Wiper motor

REFERENCE DATA 1-(1). Coil temperature rise (at room temperature)

1-(2). Coil temperature rise (at 85°C 185°F)

Sample: CQ1-12V, 5pcs Contact carrying current: 10A, 15A, 20A Ambient temperature: Room temperature

80

160 15A

120

10A 80

40

40

12

14 16 Coil applied voltage, V

0

Switching voltage, VDC

20A 15A 10A

120

Temperature rise, °C

Temperature rise, °C

160

(N.O. side Room temperature)

60

200

200

0

2. Max. switching capability (Resistive load)

Sample: CQ1-12V, 5pcs Contact carrying current: 10A, 15A Ambient temperature: 85°C 185°F

50 40 30 20 10

12

14 16 Coil applied voltage, V

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

0

0

10

20 30 40 Switching current, A

50


CQ

30 25 20 15 10 5 0 –40 –20

60

80 70 60

50

Pick-up voltage upper limit

50 40 30

Pick-up voltage lower limit 0

-40

7. Distribution of release time

Sample: CQ1-12V, 100pcs

Sample: CQ1-12V, 100pcs * With diode

90

80

80

70

70

Quantity, n

100

90

Quantity, n

100

50

30

10 0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0

85 20 Ambient temperature, °C

6. Distribution of operate time

60

40

20

10

Pick-up voltage (Cold start) 0 20 40 60 8085 100 120 Ambient temperature, °C

Operate time Release time

20

Voltage, V

60 50

40

40

30

30

20

20

10

10 0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5

0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5

Time, ms

Time, ms

Change of pick-up and drop-out voltage

Sample: CQ1-12V, 3pcs Load: Inrush current: 30A, Steady current: 5A, Brake current: 17A, wiper motor actual load (free condition) Tested voltage: 14V DC Switching frequency: (ON:OFF = 1s:2s) Ambient temperature: Room temperature

Circuit

M

14VDC

Change of contact resistance

10 Pick-up and drop-out voltage, V

8. Electrical life test (Motor free)

50 N.C. side N.O. side

9 8 Pick-up voltage

7

Max. X Min.

6 5 4

Drop-out voltage

Max. X Min.

3 2

Contact resistance, mΩ

Coil applied voltage, VDC

35

5. Distribution of pick-up and drop-out voltage Sample: CQ1-12V, 100pcs

Ratio against the rated voltage, %V

40

4. Ambient temperature characteristics

Frequency, n

3. Ambient temperature and operating temperature range

40

30

20 Max. X Min. Max. X Min.

10

1 0

0

10

20

No. of operations, × 10

30

0

0

4

Load current waveform Inrush current: 30A, Steady current: 5A, Brake current: 17A 10A 200ms

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

10

20

No. of operations, × 104

30


CQ 9-(2). Operation noise distribution

Measuring conditions

When operate

When release

Sample: CQ1-12 V, 50 pcs. Equipment setting: “A” weighted, Fast, Max. hold Coil voltage: 12V DC Coil connection device: Diode Background noise: Approx. 20dB

25

25

20

20 Frequency

Frequency

9-(1). Operation noise distribution

15

15

10

10

5

5

0 42

44

46

48

50

52

Noise level, dB

54

56

0 38

Microphone Relay

50mm 1.969inch Sponge

40

42

44

46

48

50

52

Noise level, dB

For Cautions for Use, see Relay Technical Information

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.