EV (AEV) COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY.
EV RELAYS (AEV)
FEATURES
150A 2a
150A 1a
60a
30a
• Small size & light weight: size 1/4, weight 1/2 (compared to conventional contactors) • No arc space is required: size including arc space 1/9 (compared to conventional contactors) The arc is not exposed to the outside, therefore, no arc space is not required. • Safety construction The arc is not exposed, therefore, the contactor is explosion proof and intrinsically safe. • Quiet: operation noise 1/4 (compared to conventional contactors). Along with the above-mentioned miniaturization, the operation noise has been reduced to 70dB, and, in addition, the operation noise remains unchanged
when a current of 1000A or more is interrupted. • High contact reliability The contact part is hermetically sealed with H2 mixed gas, hence the contact resistance remains stable regardless of the ambient conditions. • Mounting direction is not specified The weight of the movable parts is light, and also the restoring force is large, hence the contactor is relatively unaffected by gravity. • Line-up of indicator Type (150A Type only) A line-up of relays with indicator that can monitor the relay operation. • Coil voltage 24V DC type is also available
SPECIFICATIONS Contact
Characteristics
Type Arrangement Nominal switching capacity (resistive load) Short term current
Rating
Max. cut-off current Overload opening/ closing rating Reverse direction cut-off
150A type 1 Form A, 2 Form A
60A type
30A type
1 Form A
1 Form A
150A 400V DC
60A 400V DC
30A 400V DC
300A (10min) (40mm2) 2,500A 300V DC (3 cycles)#1
120A (15min) (15mm2)
60A (5min) (5.5mm2)
600A 300V DC (5 cycles)#3
—
600A 300V DC 120A 400V DC 120A 400V DC (25 cycles) (50 cycles)#3 (50 cycles)#3
–300A 200V DC (25 cycles) Max. 0.1V Contact When current voltage drop (is 150A per 1) contact set 35W (Inrush, Nominal operating approx 0.1s) power 5W (Stable) 1 Form A: 105 Mechanical Expected 2 Form A: life (min. 5 × 104 opera150A 400V DC tions) Electrical 103 L/R q 1ms
–120A 200V DC (50 cycles)#3 Max. 0.1V When current (is 60A per 1) contact set
–60A 200V DC (50 cycles)#3 Max. 0.2V When current (is 30A per 1) contact set
Max. 5W
Max. 5W
105 60A 400V DC 103 L/R q 1ms#3
30A 400V DC 3 × 104 L/R q 1ms#3
Initial insulation resistance Min. 100 MΩ (at 500 V DC)*1 Between open AC 2,500 Vrms for 1 min.*2 Initial contacts breakdown Between contact and voltage AC 2,500 Vrms for 1 min.*2 coil Operate time Max. 50ms*3 (at 20°C) (at nominal voltage) Reset time (without diode) Max. 30ms*4 (at 20°C) (at nominal voltage) Functional Min. 196 m/s2 {20 G}*5 Shock resistance Destructive Min. 490 m/s2 {50 G}*6 Functional 43 m/s2 {4.4 G} 10 Hz to 200 Hz*7 Vibration resistance Destructive 43 m/s2 {4.4 G} 10 Hz to 200 Hz*8 Conditions for operation, Ambient –40°C to +80°C*9 –40°F to +176°F transport and storage (Not temperature freezing and condensing Humidity 5% R.H. to 85% R.H. at low temperature) 150 A 1 Form A: 600 g 21.16oz 150 A 2 Form A: 1,100 g 38.80oz Mass 60 A: 330 g 11.64oz 30 A: 310 g 10.93oz Remarks *1 Measurement at same location as “Initial breakdown voltage” section. *2 Detection current: 10mA. *3 Nominal voltage applied to the coil,excluding bounce time. *4 Nominal voltage applied to the coil. *5 Half-wave pulse of sine wave: 11 ms; detection time: 10µs. *6 Half-wave pulse of sine wave: 6 ms. *7 Detection time: 10 µs. *8 3 directions, each 4 hours. *9 Storage: Max.85°C 185°F.
Notes * Same specifications as the 12 V type. #1 Condition: Nominal switching 100 cycles,each cut off 2,500 A. #2 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT #3 The electrical load performance value for the 60 A and 30 A types applies when a varistor is connected in parallel to the coil. Please be warned that working life will be reduced when a diode is used.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
EV (AEV) Indicator ratings Arrangement Material Rating (resistive load) Contact resistance
1 Form A
1 Form B Gold-clad 0.1 A 30 V DC (Low level load = min. 1 mA) Max. 100 mΩ
Note: Indicator type is only available for the 150 A type.
TYPICAL APPLICATIONS • Electric Vehicle • Hybrid Electric Vehicle
ORDERING INFORMATION Ex.
A
EV
1
5
0
Product Name
Contact arrangement
Contact rating
EV
1: 1 Form A 2: 2 Form A (150A type)
3: 30A 5: 150A 6: 60A
Packing quantity Types 150A 2 Form A 150A 1 Form A 60A 1 Form A 30A 1 Form A
Inner 1pc. 1pc. 1pc. 1pc.
12 Indicator contact arrangement 0: without indicator contact 1: a contact (150A type only) 3: b contact (150A type only)
Coil voltage 12: 12V DC 24: 24V DC
SPARE PARTS Outer 5pcs. 10pcs. 20pcs. 20pcs.
Installing parts M8 nut with washer for 150A type M5 screw for 60A type M4 screw for 30A type Bus bar for 60A type
Part No. AEV801 AEV802 AEV803 AEV804
Packing Quantity 2pcs. 2pcs. 2pcs. 2pcs.
TYPES AND COIL DATA (at 20°C 68°F) Part No.
Coil voltage, V DC
Pick-up voltage, V DC
Drop-out voltage, V DC
AEV25012* AEV15012* 12 V DC
Max. 9 V DC
AEV13012 AEV25024* 24 V DC
AEV16024 AEV13024
Max. 18 V DC
Operating power, W (12 V DC)
2.8 A ±10% (at peak)*
35W (Inrush, approx. 0.1S) 5W (Stable)
Min. 1 V DC
AEV16012
AEV15024*
Nominal coil current
Min. 2 V DC
Max. allowable voltage, V DC
16 V DC 0.415 A ±10%
Max. 5W
1.9 A ±10% (at peak)* 2.2 A ±10% (at peak)*
35W (Inrush, approx. 0.1S) Max. 5W (1 Form A) Max. 6W (2 Form A)
0.208 A ±10%
Max. 5W
Note: * Same coil data as Indicator type.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
32 V DC
EV (AEV) DIMENSIONS
mm inch
150A 2a
Schematic (TOP VIEW)
Main terminal M8: AEV801 (included) 4-5.3 +0.3 −0.1 dia. 4-.209+.012 −.004 dia. (Width across nut: 12 mm .472 inch) 3 -
123
4+ 2 -
GND/AVX(Green) wire diameter 0.5sq V+/AVX(White) wire diameter 0.5sq
XYZ
+4
3-
Coil( ) Coil( )
14 .551
789
456 98
1+
300±10 (lead wire) 11.811±.394
3
4
1
2
123
789
456 98
XYZ
87.0 3.425 34.0 1.339
75.0±0.3 2.953±.012
output side has polarities (+) and (-)
29.0 1.142 1+
Mounting dimensions
- 2
27.0 1.063 66.0 2.598 76.0±0.3 2.992±.012 88.0 3.465
5 .197
3.5 .138
76 2.992
75 2.953
4-5.3 dia 4-.209 dia
87.1 3.429
73.5 2.894 (Terminal height)
73.0 2.874
General tolerance: less than 10 (.394) ±0.3 (±.012) 10 (.394) to 50 (1.969) ±0.6 (±.024) more than 50 (1.969) ±1.0 (±.039)
13.3 .524 Plate (Lot No.)
150A 2a Indicator Type
Schematic (TOP VIEW)
Main terminal M8: AEV801 (included) 4-5.3 +0.3 −0.1 dia. 4-.209+.012 −.004 dia. (Width across nut: 12 mm .472 inch)
XYZ
1+
4+
14 .551
789
456 98
123
3 -
300±10(lead wire) 11.811±.394
2 -
GND/AVX(Green) wire diameter 0.5sq V+/AVX(White) wire diameter 0.5sq
+4
3-
Coil(+) Coil(–)
NO/AVX(Blue) wire diameter 0.5sq/AEV25112,25124 NC/AVX(Red) wire diameter 0.5sq/AEV25312,25324
123
789
456 98
XYZ
87.0 3.425 34.0 1.339
75.0±0.3 2.953±.012
3–
4+
1+
2– Indicator: NO or NC Indicator: COM
COM/AVX(Black) wire diameter 0.5sq
output side has polarities (+) and (-)
29.0 1.142 1+
Mounting dimensions
- 2
6 .236 27.0 1.063 66.0 2.598 76.0±0.3 2.992±.012 88.0 3.465
3.5 .138
5 .197
76 2.992
75 2.953
4-5.3 dia 4-.209 dia
87.1 3.429
13.3 .524 Plate (Lot No.)
73.5 2.894 (Terminal height)
73.0 2.874
General tolerance: less than 10 (.394) ±0.3 (±.012) 10 (.394) to 50 (1.969) ±0.6 (±.024) more than 50 (1.969) ±1.0 (±.039)
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
EV (AEV) 150A 1a
mm inch
Main terminal M8: AEV801 (included) 2-5.3 +0.3 −0.1 dia. (Width across nut: 12 mm .472 inch) 2-.209+.012 −.004 dia. 456 98
123
XYZ
123
789
456 98
XYZ
29.0 1.142 19.5 .768
Coil( ) Coil( )
14 .551
2 -
789
1 +
Schematic (TOP VIEW)
300±10(lead wire) 11.811±.394
41.0±0.3 1.614±.012
53.0 2.087
V+/AVX(White) wire diameter 0.5sq GND/AVX(Green) wire diameter 0.5sq 1
2
output side has polarities (+) and (-) 1+
-2
6 .236
3.5 .138
27.0 1.063 64.0 2.520 74.0 2.913 76.0±0.3 2.992±.012 88.0 3.465
Mounting dimensions 76 2-5.3 dia 2.992 2-.209 dia
41 1.614
87.1 3.429
73.5 2.894 (Terminal height)
13.3 .524
73.0 2.874
General tolerance: less than 10 (.394) ±0.3 (±.012) 10 (.394) to 50 (1.969) ±0.6 (±.024) more than 50 (1.969) ±1.0 (±.039)
0.5 .020
Plate (Lot No.)
150A 1a Indicator Type
Schematic (TOP VIEW)
Main terminal M8: AEV801 (included) 2-5.3 +0.3 −0.1 dia. (Width across nut: 12 mm .472 inch) 2-.209+.012 −.004 dia. 456 98
123
14 .551
2 -
789
1 +
Coil(+) Coil(–)
300±10(lead wire) 11.811±.394
V+/AVX(White) wire diameter 0.5sq
1+
XYZ
GND/AVX(Green) wire diameter 0.5sq 123
789
456 98
XYZ
29.0 1.142 19.5 .768
41.0±0.3 1.614±.012 1+
53.0 2.087
NO/AVX(Blue) wire diameter 0.5sq/AEV15112,15124 NC/AVX(Red) wire diameter 0.5sq/AEV15312,15324
2– Indicator: NO or NC Indicator: COM
output side has polarities (+) and (-)
COM/AVX(Black) wire diameter 0.5sq
-2
27.0 1.063 64.0 2.520 74.0 2.913 76.0±0.3 2.992±0.012 88.0 3.465
6 .236
3.5 .138
Mounting dimensions 76 2-5.3 dia 2.992 2-.209 dia
41 1.614
87.1 3.429 13.3 .524
73.5 2.894 (Terminal height)
73.0 2.874
0.5 .020
Plate (Lot No.)
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
General tolerance: less than 10 (.394) ±0.3 (±.012) 10 (.394) to 50 (1.969) ±0.6 (±.024) more than 50 (1.969) ±1.0 (±.039)
EV (AEV) 60A
mm inch 79.9 3.146 45.0 1.772
Schematic (TOP VIEW) Coil
123
789
456 98
XYZ
30.2 38.0 1.189 26.0±0.3 1.496 1.024±.012
13.0 .512 1 +
V+.GND/AEX(Gray) wire diameter 0.5sq *Input coil wire is not polarized
2 -
1
2-5.3 +0.3 −0.1 dia. 2-.209+.012 −.004 dia.
49.0 1.929 61.0±0.3 2.402±.012 63.9 2.480 73.0 2.874
2
output side has polarities (+) and (-)
300±10 (lead wire) 11.811±.394
Mounting dimension 61 2.402
M5screw: AEV802
M4screw: AEV803 (installed)
26 1.024
2-5.3 dia 2-.209 dia
Bus bar (153q): AEV804 (installed) 71.0 2.795 62.0 2.441 (terminal height)
123
789
456 98
General tolerance: less than 10 (.394) ±0.3 (±.012) 10 (.394) to 50 (1.969) ±0.6 (±.024) more than 50 (1.969) ±1.0 (±.039)
XYZ
14.5 .571 10 .394
14 .551
30A
Schematic (TOP VIEW) M4screw:AEV803 Coil
123
789
456 98
XYZ
30.2 38.0 1.189 26.0±0.3 1.496 1.024±.012
2 -
1 +
2-5.3 +0.3 −0.1 dia. 2-.209+.012 −.004 dia.
14.0 .551 1
V+GND/AEX(Gray) wire diameter 0.5sq *Input coil wire is not polarized
2
output side has polarities (+) and (-)
2.5 .098
17.9 .705 45.0 1.772 49.0 1.929 61.0±0.3 2.402±.012 73.0 2.874
300±10 (lead wire) 11.811±.394
Mounting dimension 61 2.402 26 1.024
71.0 2.795
General tolerance: less than 10 (.394) ±0.3 (±.012) 10 (.394) to 50 (1.969) ±0.6 (±.024) more than 50 (1.969) ±1.0 (±.039)
123
456 98
789
XYZ
62.5 2.461 (terminal height) 14.5 .571
10 .394
REFERENCE DATA Sample: AEV15012,3pcs
Sample: AEV16012,3pcs
-20 -40 0 Ambient temperature, C
10
6 4 2 20
-6
Ambient temperature, C -20 -40 0
Pick-Up voltage
40
-2 -4
Operate time
x
Drop-out voltage
60
Variation ratio, %
1-(2) Ambient temperature characteristics (60A type)
Variation ratio, %
1-(1) Ambient temperature characteristics (150A type)
8
2-5.3 dia 2-.209 dia
80x x
40 x
30 20
Drop-out voltage
x
10 20 -10
Pick-Up voltage
x
40
60
80
Operate time
-20
-8
-30
-10
-40
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
EV (AEV) NOTES 1. When installing the relay, always use washers to prevent loosening of the screws. Tighten each of the screws within the rated ranges given below. Exceeding the maximum torque may result in breakage. Mounting is possible in either direction. • M8 screw (for 150 A main terminal): 8 to 10 N·m • M5 screw (150 A, 60 A, 30 A main unit mounting section) (60 A main terminal): 2.5 to 3.6 N·m • M4 screw (30 A terminal): 1.8 to 2.7 N·m 2. The coils (150 A type) and contacts (30 A, 60 A, 150 A) of the relay are polarized, so follow the instructions in the connection schematic when connecting the coils and contacts. Type 150 A has contains a reverse surge voltage absorption circuit; therefore a surge protector is not needed. We recommend installing a surge protector varistor (ZNR) for the 30 A and 60 A types. Avoid using a diode as this may result in decreased cut-off capability. 3. As a general rule, do not use a relay if it has been dropped. 4. Avoid mounting the relay in strong magnetic fields (near a transformer or magnet) or close to an object that radiates heat. 5. Electrical life This relay is a high-voltage direct-current switch. In its final breakdown mode, it may lose the ability to provide the proper cut-off. Therefore, do not exceed the indicated switching capacity and life. (Please treat the relay as a product with limited life and replace it when necessary.) In the event that the relay loses cut-off ability, there is a possibility that burning may spread to surrounding parts, so configure the layout so that the power is turned off within one second. When using the 30 A type, to prevent increases in the contact resistance, do not allow switching without any load.
6. Permeation life of internal gas This relay uses a hermetically encased contact (capsule contact) with gas inside. The gas has a permeation life that is affected by the temperature inside the capsule contact (ambient temperature + temperature rise due to flow of electrical current). For this reason, make sure the ambient operating temperature is between –40 and 80°C –40 and +176°F, and the ambient storage temperature is between –40 and 85°C –40 and +185°F. 7. If the power is turned off and then immediately on after applying the rated voltage (current) continuously to the relay’s coil and contact, the resistance of the coil will increase due to a rise in the coil temperature. This causes the pick-up voltage to rise, and possibly exceed the rated pick-up voltage. In these circumstances, take measures such as reducing the load current, limiting the duration of current flow, and applying a coil voltage higher than the rated operating voltage (quick start). 8. Main contact ratings in the ratings apply to when there is a resistive load. If you are using an inductive load (L load) such that L/R > 1 ms, add surge protection in parallel with the inductive load. If this is not done, the electrical life will decrease and cut-off failure may occur. 9. When using the 150 A type, mount it as far away as possible from amateur wireless transmitters or devices that may generate large surges. To prevent malfunctioning due to high emission levels, it may be necessary to take measures for E.M.I., such as adding a line noise filter or an electromagnetic shield. 10. Since coil current control is performed, a slight amount of superimposed line noise may be generated in the input line system. If this noise must be removed, install a line noise filter.
11. Be careful that foreign matter and oils and fats kind doesn't stick to the main terminal part because it is likely to cause a terminal part to give off unusual heat. 12. Avoid excessive load applied to the terminal in case of installing such as a bus bar etc., because it might give bad influence to the opening and closing performance. • M8 screw terminal (150A main terminal part) Terminal pulling up strength; Max.100N per terminal The up-down rotation torque applied to the terminal; Max.15N·m 13. When the 150 A type is driven, sufficient current capacity is required when power is applied. When stabilized DC voltage is used, please verify that nominal coil current during peeks has a capacity of 150% or more for each relay.
For Cautions for Use, see Relay Technical Information