EV (AEV) COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY.

EV RELAYS (AEV)

FEATURES

150A 2a

150A 1a

60a

30a

• Small size & light weight: size 1/4, weight 1/2 (compared to conventional contactors) • No arc space is required: size including arc space 1/9 (compared to conventional contactors) The arc is not exposed to the outside, therefore, no arc space is not required. • Safety construction The arc is not exposed, therefore, the contactor is explosion proof and intrinsically safe. • Quiet: operation noise 1/4 (compared to conventional contactors). Along with the above-mentioned miniaturization, the operation noise has been reduced to 70dB, and, in addition, the operation noise remains unchanged

when a current of 1000A or more is interrupted. • High contact reliability The contact part is hermetically sealed with H2 mixed gas, hence the contact resistance remains stable regardless of the ambient conditions. • Mounting direction is not specified The weight of the movable parts is light, and also the restoring force is large, hence the contactor is relatively unaffected by gravity. • Line-up of indicator Type (150A Type only) A line-up of relays with indicator that can monitor the relay operation. • Coil voltage 24V DC type is also available

SPECIFICATIONS Contact

Characteristics

Type Arrangement Nominal switching capacity (resistive load) Short term current

Rating

Max. cut-off current Overload opening/ closing rating Reverse direction cut-off

150A type 1 Form A, 2 Form A

60A type

30A type

1 Form A

1 Form A

150A 400V DC

60A 400V DC

30A 400V DC

300A (10min) (40mm2) 2,500A 300V DC (3 cycles)#1

120A (15min) (15mm2)

60A (5min) (5.5mm2)

600A 300V DC (5 cycles)#3

600A 300V DC 120A 400V DC 120A 400V DC (25 cycles) (50 cycles)#3 (50 cycles)#3

–300A 200V DC (25 cycles) Max. 0.1V Contact When current voltage drop (is 150A per 1) contact set 35W (Inrush, Nominal operating approx 0.1s) power 5W (Stable) 1 Form A: 105 Mechanical Expected 2 Form A: life (min. 5 × 104 opera150A 400V DC tions) Electrical 103 L/R q 1ms

–120A 200V DC (50 cycles)#3 Max. 0.1V When current (is 60A per 1) contact set

–60A 200V DC (50 cycles)#3 Max. 0.2V When current (is 30A per 1) contact set

Max. 5W

Max. 5W

105 60A 400V DC 103 L/R q 1ms#3

30A 400V DC 3 × 104 L/R q 1ms#3

Initial insulation resistance Min. 100 MΩ (at 500 V DC)*1 Between open AC 2,500 Vrms for 1 min.*2 Initial contacts breakdown Between contact and voltage AC 2,500 Vrms for 1 min.*2 coil Operate time Max. 50ms*3 (at 20°C) (at nominal voltage) Reset time (without diode) Max. 30ms*4 (at 20°C) (at nominal voltage) Functional Min. 196 m/s2 {20 G}*5 Shock resistance Destructive Min. 490 m/s2 {50 G}*6 Functional 43 m/s2 {4.4 G} 10 Hz to 200 Hz*7 Vibration resistance Destructive 43 m/s2 {4.4 G} 10 Hz to 200 Hz*8 Conditions for operation, Ambient –40°C to +80°C*9 –40°F to +176°F transport and storage (Not temperature freezing and condensing Humidity 5% R.H. to 85% R.H. at low temperature) 150 A 1 Form A: 600 g 21.16oz 150 A 2 Form A: 1,100 g 38.80oz Mass 60 A: 330 g 11.64oz 30 A: 310 g 10.93oz Remarks *1 Measurement at same location as “Initial breakdown voltage” section. *2 Detection current: 10mA. *3 Nominal voltage applied to the coil,excluding bounce time. *4 Nominal voltage applied to the coil. *5 Half-wave pulse of sine wave: 11 ms; detection time: 10µs. *6 Half-wave pulse of sine wave: 6 ms. *7 Detection time: 10 µs. *8 3 directions, each 4 hours. *9 Storage: Max.85°C 185°F.

Notes * Same specifications as the 12 V type. #1 Condition: Nominal switching 100 cycles,each cut off 2,500 A. #2 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT #3 The electrical load performance value for the 60 A and 30 A types applies when a varistor is connected in parallel to the coil. Please be warned that working life will be reduced when a diode is used.

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.


EV (AEV) Indicator ratings Arrangement Material Rating (resistive load) Contact resistance

1 Form A

1 Form B Gold-clad 0.1 A 30 V DC (Low level load = min. 1 mA) Max. 100 mΩ

Note: Indicator type is only available for the 150 A type.

TYPICAL APPLICATIONS • Electric Vehicle • Hybrid Electric Vehicle

ORDERING INFORMATION Ex.

A

EV

1

5

0

Product Name

Contact arrangement

Contact rating

EV

1: 1 Form A 2: 2 Form A (150A type)

3: 30A 5: 150A 6: 60A

Packing quantity Types 150A 2 Form A 150A 1 Form A 60A 1 Form A 30A 1 Form A

Inner 1pc. 1pc. 1pc. 1pc.

12 Indicator contact arrangement 0: without indicator contact 1: a contact (150A type only) 3: b contact (150A type only)

Coil voltage 12: 12V DC 24: 24V DC

SPARE PARTS Outer 5pcs. 10pcs. 20pcs. 20pcs.

Installing parts M8 nut with washer for 150A type M5 screw for 60A type M4 screw for 30A type Bus bar for 60A type

Part No. AEV801 AEV802 AEV803 AEV804

Packing Quantity 2pcs. 2pcs. 2pcs. 2pcs.

TYPES AND COIL DATA (at 20°C 68°F) Part No.

Coil voltage, V DC

Pick-up voltage, V DC

Drop-out voltage, V DC

AEV25012* AEV15012* 12 V DC

Max. 9 V DC

AEV13012 AEV25024* 24 V DC

AEV16024 AEV13024

Max. 18 V DC

Operating power, W (12 V DC)

2.8 A ±10% (at peak)*

35W (Inrush, approx. 0.1S) 5W (Stable)

Min. 1 V DC

AEV16012

AEV15024*

Nominal coil current

Min. 2 V DC

Max. allowable voltage, V DC

16 V DC 0.415 A ±10%

Max. 5W

1.9 A ±10% (at peak)* 2.2 A ±10% (at peak)*

35W (Inrush, approx. 0.1S) Max. 5W (1 Form A) Max. 6W (2 Form A)

0.208 A ±10%

Max. 5W

Note: * Same coil data as Indicator type.

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

32 V DC


EV (AEV) DIMENSIONS

mm inch

150A 2a

Schematic (TOP VIEW)

Main terminal M8: AEV801 (included) 4-5.3 +0.3 −0.1 dia. 4-.209+.012 −.004 dia. (Width across nut: 12 mm .472 inch) 3 -

123

4+ 2 -

GND/AVX(Green) wire diameter 0.5sq V+/AVX(White) wire diameter 0.5sq

XYZ

+4

3-

Coil( ) Coil( )

14 .551

789

456 98

1+

300±10 (lead wire) 11.811±.394

3

4

1

2

123

789

456 98

XYZ

87.0 3.425 34.0 1.339

75.0±0.3 2.953±.012

output side has polarities (+) and (-)

29.0 1.142 1+

Mounting dimensions

- 2

27.0 1.063 66.0 2.598 76.0±0.3 2.992±.012 88.0 3.465

5 .197

3.5 .138

76 2.992

75 2.953

4-5.3 dia 4-.209 dia

87.1 3.429

73.5 2.894 (Terminal height)

73.0 2.874

General tolerance: less than 10 (.394) ±0.3 (±.012) 10 (.394) to 50 (1.969) ±0.6 (±.024) more than 50 (1.969) ±1.0 (±.039)

13.3 .524 Plate (Lot No.)

150A 2a Indicator Type

Schematic (TOP VIEW)

Main terminal M8: AEV801 (included) 4-5.3 +0.3 −0.1 dia. 4-.209+.012 −.004 dia. (Width across nut: 12 mm .472 inch)

XYZ

1+

4+

14 .551

789

456 98

123

3 -

300±10(lead wire) 11.811±.394

2 -

GND/AVX(Green) wire diameter 0.5sq V+/AVX(White) wire diameter 0.5sq

+4

3-

Coil(+) Coil(–)

NO/AVX(Blue) wire diameter 0.5sq/AEV25112,25124 NC/AVX(Red) wire diameter 0.5sq/AEV25312,25324

123

789

456 98

XYZ

87.0 3.425 34.0 1.339

75.0±0.3 2.953±.012

3–

4+

1+

2– Indicator: NO or NC Indicator: COM

COM/AVX(Black) wire diameter 0.5sq

output side has polarities (+) and (-)

29.0 1.142 1+

Mounting dimensions

- 2

6 .236 27.0 1.063 66.0 2.598 76.0±0.3 2.992±.012 88.0 3.465

3.5 .138

5 .197

76 2.992

75 2.953

4-5.3 dia 4-.209 dia

87.1 3.429

13.3 .524 Plate (Lot No.)

73.5 2.894 (Terminal height)

73.0 2.874

General tolerance: less than 10 (.394) ±0.3 (±.012) 10 (.394) to 50 (1.969) ±0.6 (±.024) more than 50 (1.969) ±1.0 (±.039)

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.


EV (AEV) 150A 1a

mm inch

Main terminal M8: AEV801 (included) 2-5.3 +0.3 −0.1 dia. (Width across nut: 12 mm .472 inch) 2-.209+.012 −.004 dia. 456 98

123

XYZ

123

789

456 98

XYZ

29.0 1.142 19.5 .768

Coil( ) Coil( )

14 .551

2 -

789

1 +

Schematic (TOP VIEW)

300±10(lead wire) 11.811±.394

41.0±0.3 1.614±.012

53.0 2.087

V+/AVX(White) wire diameter 0.5sq GND/AVX(Green) wire diameter 0.5sq 1

2

output side has polarities (+) and (-) 1+

-2

6 .236

3.5 .138

27.0 1.063 64.0 2.520 74.0 2.913 76.0±0.3 2.992±.012 88.0 3.465

Mounting dimensions 76 2-5.3 dia 2.992 2-.209 dia

41 1.614

87.1 3.429

73.5 2.894 (Terminal height)

13.3 .524

73.0 2.874

General tolerance: less than 10 (.394) ±0.3 (±.012) 10 (.394) to 50 (1.969) ±0.6 (±.024) more than 50 (1.969) ±1.0 (±.039)

0.5 .020

Plate (Lot No.)

150A 1a Indicator Type

Schematic (TOP VIEW)

Main terminal M8: AEV801 (included) 2-5.3 +0.3 −0.1 dia. (Width across nut: 12 mm .472 inch) 2-.209+.012 −.004 dia. 456 98

123

14 .551

2 -

789

1 +

Coil(+) Coil(–)

300±10(lead wire) 11.811±.394

V+/AVX(White) wire diameter 0.5sq

1+

XYZ

GND/AVX(Green) wire diameter 0.5sq 123

789

456 98

XYZ

29.0 1.142 19.5 .768

41.0±0.3 1.614±.012 1+

53.0 2.087

NO/AVX(Blue) wire diameter 0.5sq/AEV15112,15124 NC/AVX(Red) wire diameter 0.5sq/AEV15312,15324

2– Indicator: NO or NC Indicator: COM

output side has polarities (+) and (-)

COM/AVX(Black) wire diameter 0.5sq

-2

27.0 1.063 64.0 2.520 74.0 2.913 76.0±0.3 2.992±0.012 88.0 3.465

6 .236

3.5 .138

Mounting dimensions 76 2-5.3 dia 2.992 2-.209 dia

41 1.614

87.1 3.429 13.3 .524

73.5 2.894 (Terminal height)

73.0 2.874

0.5 .020

Plate (Lot No.)

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

General tolerance: less than 10 (.394) ±0.3 (±.012) 10 (.394) to 50 (1.969) ±0.6 (±.024) more than 50 (1.969) ±1.0 (±.039)


EV (AEV) 60A

mm inch 79.9 3.146 45.0 1.772

Schematic (TOP VIEW) Coil

123

789

456 98

XYZ

30.2 38.0 1.189 26.0±0.3 1.496 1.024±.012

13.0 .512 1 +

V+.GND/AEX(Gray) wire diameter 0.5sq *Input coil wire is not polarized

2 -

1

2-5.3 +0.3 −0.1 dia. 2-.209+.012 −.004 dia.

49.0 1.929 61.0±0.3 2.402±.012 63.9 2.480 73.0 2.874

2

output side has polarities (+) and (-)

300±10 (lead wire) 11.811±.394

Mounting dimension 61 2.402

M5screw: AEV802

M4screw: AEV803 (installed)

26 1.024

2-5.3 dia 2-.209 dia

Bus bar (153q): AEV804 (installed) 71.0 2.795 62.0 2.441 (terminal height)

123

789

456 98

General tolerance: less than 10 (.394) ±0.3 (±.012) 10 (.394) to 50 (1.969) ±0.6 (±.024) more than 50 (1.969) ±1.0 (±.039)

XYZ

14.5 .571 10 .394

14 .551

30A

Schematic (TOP VIEW) M4screw:AEV803 Coil

123

789

456 98

XYZ

30.2 38.0 1.189 26.0±0.3 1.496 1.024±.012

2 -

1 +

2-5.3 +0.3 −0.1 dia. 2-.209+.012 −.004 dia.

14.0 .551 1

V+GND/AEX(Gray) wire diameter 0.5sq *Input coil wire is not polarized

2

output side has polarities (+) and (-)

2.5 .098

17.9 .705 45.0 1.772 49.0 1.929 61.0±0.3 2.402±.012 73.0 2.874

300±10 (lead wire) 11.811±.394

Mounting dimension 61 2.402 26 1.024

71.0 2.795

General tolerance: less than 10 (.394) ±0.3 (±.012) 10 (.394) to 50 (1.969) ±0.6 (±.024) more than 50 (1.969) ±1.0 (±.039)

123

456 98

789

XYZ

62.5 2.461 (terminal height) 14.5 .571

10 .394

REFERENCE DATA Sample: AEV15012,3pcs

Sample: AEV16012,3pcs

-20 -40 0 Ambient temperature, C

10

6 4 2 20

-6

Ambient temperature, C -20 -40 0

Pick-Up voltage

40

-2 -4

Operate time

x

Drop-out voltage

60

Variation ratio, %

1-(2) Ambient temperature characteristics (60A type)

Variation ratio, %

1-(1) Ambient temperature characteristics (150A type)

8

2-5.3 dia 2-.209 dia

80x x

40 x

30 20

Drop-out voltage

x

10 20 -10

Pick-Up voltage

x

40

60

80

Operate time

-20

-8

-30

-10

-40

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.


EV (AEV) NOTES 1. When installing the relay, always use washers to prevent loosening of the screws. Tighten each of the screws within the rated ranges given below. Exceeding the maximum torque may result in breakage. Mounting is possible in either direction. • M8 screw (for 150 A main terminal): 8 to 10 N·m • M5 screw (150 A, 60 A, 30 A main unit mounting section) (60 A main terminal): 2.5 to 3.6 N·m • M4 screw (30 A terminal): 1.8 to 2.7 N·m 2. The coils (150 A type) and contacts (30 A, 60 A, 150 A) of the relay are polarized, so follow the instructions in the connection schematic when connecting the coils and contacts. Type 150 A has contains a reverse surge voltage absorption circuit; therefore a surge protector is not needed. We recommend installing a surge protector varistor (ZNR) for the 30 A and 60 A types. Avoid using a diode as this may result in decreased cut-off capability. 3. As a general rule, do not use a relay if it has been dropped. 4. Avoid mounting the relay in strong magnetic fields (near a transformer or magnet) or close to an object that radiates heat. 5. Electrical life This relay is a high-voltage direct-current switch. In its final breakdown mode, it may lose the ability to provide the proper cut-off. Therefore, do not exceed the indicated switching capacity and life. (Please treat the relay as a product with limited life and replace it when necessary.) In the event that the relay loses cut-off ability, there is a possibility that burning may spread to surrounding parts, so configure the layout so that the power is turned off within one second. When using the 30 A type, to prevent increases in the contact resistance, do not allow switching without any load.

6. Permeation life of internal gas This relay uses a hermetically encased contact (capsule contact) with gas inside. The gas has a permeation life that is affected by the temperature inside the capsule contact (ambient temperature + temperature rise due to flow of electrical current). For this reason, make sure the ambient operating temperature is between –40 and 80°C –40 and +176°F, and the ambient storage temperature is between –40 and 85°C –40 and +185°F. 7. If the power is turned off and then immediately on after applying the rated voltage (current) continuously to the relay’s coil and contact, the resistance of the coil will increase due to a rise in the coil temperature. This causes the pick-up voltage to rise, and possibly exceed the rated pick-up voltage. In these circumstances, take measures such as reducing the load current, limiting the duration of current flow, and applying a coil voltage higher than the rated operating voltage (quick start). 8. Main contact ratings in the ratings apply to when there is a resistive load. If you are using an inductive load (L load) such that L/R > 1 ms, add surge protection in parallel with the inductive load. If this is not done, the electrical life will decrease and cut-off failure may occur. 9. When using the 150 A type, mount it as far away as possible from amateur wireless transmitters or devices that may generate large surges. To prevent malfunctioning due to high emission levels, it may be necessary to take measures for E.M.I., such as adding a line noise filter or an electromagnetic shield. 10. Since coil current control is performed, a slight amount of superimposed line noise may be generated in the input line system. If this noise must be removed, install a line noise filter.

11. Be careful that foreign matter and oils and fats kind doesn't stick to the main terminal part because it is likely to cause a terminal part to give off unusual heat. 12. Avoid excessive load applied to the terminal in case of installing such as a bus bar etc., because it might give bad influence to the opening and closing performance. • M8 screw terminal (150A main terminal part) Terminal pulling up strength; Max.100N per terminal The up-down rotation torque applied to the terminal; Max.15N·m 13. When the 150 A type is driven, sufficient current capacity is required when power is applied. When stabilized DC voltage is used, please verify that nominal coil current during peeks has a capacity of 150% or more for each relay.

For Cautions for Use, see Relay Technical Information