Miguel Dobbs Asti Jackson Talon McCart Location_1219 Broadway, Lubbock, TX, 79401
zilla
Lubbock Building Codes
Site Dimensions
Sec. 28.09.043 The construction documents shall show int sufficient detail the location, construction, size and character of all portions
B road w a y
construction documents shall designate the number of occupants to be accommodated on every floor and in all spaces. Fire Prevention Sec. 201.00 A) AUTOMATIC FIRE-EXTINGUISHING SYSTEM. See Section 902.1. B) AUTOMATIC SMOKE DETECTION SYSTEM. See Section 902.1. C) AUTOMATIC SPRINKLER SYSTEM. See Section 902.1.
120’
120’
of the means of egress in compliance with the provisions of this code. In other than occupancies in group R-3, the
Site Location
International Building Codes Assessment - Construction Classi cation – Type 1A - Use and Occupancy Classi - Group B : Business - Group M : Mercantile - Height Restrictions - UL Height Limit - IBC Type 1A Construction - Unlimited Height - Lubbock CB-2 Zone - Local Zoning Code - CB-2 - Central Business District Broadway - 13th - Main
N
- “CB-2” Central Business District, Broadway/13th/Main Structural Steel - Columns Nominal Column Size due to Tributary Area Unbraced Height Wide Flange Section- W4-4x4”, W6- 6x4” or 6x6”, W8- 8x4” 8x5” Hollow Section HSS4- 4x4”, HSS6- 6x6”
Live Load Ranges ce Buildings 40 psf to 100 psf Stores 80 psf to 125 psf Misc. Public Facilities 80 psf to 125 psf Building Corridors 100 psf Roof Loads 20 psf to 150 psf
O
Live Load Ranges for Steel Conventional Steel Frame Medium Loads to Very Heavy Loads Lateral Stability possibilities for Steel Rigid Frame - requires welded connections Semi-Rigid Joints with Supplemental braced Frame Braced Frame Shear Wall - sitecast concrete
Structural Steel - Floor and Roof Decking Span and Depth Floor Decking Minimum 2” Maximum 8” Roof Decking Minimum 1” Maximum 4” Structural Steel - Wide Flange Beams and Girders Span Depth Beams 12’-70’ 8”-36” Composite Beams 14‘-75’ 8“-36” Girders 10’-60’ 8”-36”
35’ 35’
SECTION 304 BUSINESS GROUP B 304.1 Business Group B. Business Group B occupancy includes, among others, the use of a building or structure, or a ce, professional or service-type transactions, portion thereof, for o including storage of records and accounts. SECTION 309 MERCANTILE GROUP M 309.1 Mercantile Group M. Mercantile Group M occupancy includes, among others, the use of a building or structure or a portion thereof, for the display and sale of merchandise and involves stocks of goods, wares or merchandise incidental to such purposes and accessible to the public. Section 602 CONSTRUCTION CLASSIFICATION 602.2 Types I and II. Types I and II construction are those types of construction in which the building elements listed in Table 601 are of noncombustible materials, except as permitted in Section 603 and elsewhere in this code. Local
ARCH zilla
Avenue L
Flood Requirements A) No ooding requirements for building location and zoning location. B) Adjacent to areas of 0.2% annual change one foot or with drainage areas less than 1 square mile; and areas protected by levees from 1% annual chance
Division 17. Setback Requirements North: 13’6” sidewalk East: 19’6” ally way South: 15’ back ally West: 10’6” sidewalk
Means of Egress
Restaurant Offices Lobby
ARCH zilla Mass Models
Cladding Development The cladding systems designed for this proposal were created to allow maximum lighting and minimal energy use. There is a use of mixed materials. Glazing is used to its minimum along the east and west facade in some versions concrete is replaced by metal panels to provide aesthetical qualities and to suggest structure. Core Development The formal qualities of this massing made it difficult to accomodate a single service core. instead it had to be split into to flanking structures of the massing. this allowed for an even distribution of services since the middle structure creates the connection between two flanks. Analysis & Discussion Due to the slanted roofs and the extra service core in this massing proposal the cost of running it would be exponentially more expensive than the other proposals. Despite the costs the proposal provides a more dynamic and aestetically pleasing form that can be further manipulated and explored to create a more undifined building. The way the roofs slant in different directions can be a good starting point for winter and summer lighting.
Annual Utility Consumption by End Use
Monthly Utility Consumption by End Use
Analysis Summary
Net Present Value Over 15 Years Initial Mechanical System Cost: First Year's Electricity Cost: First Year's Natural Gas Cost: Net Present Value:
$593,330.80
Peak Building Load:
$39,566.00
Peak Electrical Load:
$4,047.00 $0.00
Electricity Use: Natural Gas Use:
125
Tons
362.50
269
SF / Ton
kW
5.94
10.84
kWh / SF
$0.0806
/ Unit
7.30
kBtu / SF
$1.3155
/ Unit
W / SF
ARCH zilla
Preliminary Design Energy Analysis
We selected this proposal because its future potential due to its formal qualities. We also chose this massing because the way it allows lighting in and how the program is accomodated. It is not the most cost effective but be believe there are ways that we can reduce costs.
ADA Accessible Bathroom
Mens Restroom
Womans Restroom
Plumbing Wall
Floor Plan_Ground
J
Restrooms 18
15
Janitors Closet
14
H
Supply & Return Air Risers 16
13
G
Switch Gear Room
19
20
Breaker Box
01
03
17 x 8 1/2" = 12'-0"
17 x 8 1/2" = 12'-0"
8
10
Stairwell
9
11
12
14
13
15
16
17
8 17
16
15
14
9
11
13
12
10
16
15
Electrical Riser
7
6
5
4
3
2
1
2
1
3
4
6
5
7
F
14
E
Lobby D
18
Office Space
17 16 15 14
C
13 12 11 10
9
8 7 6 5 4 3
Central Walkway Stairs
18 x 8" = 12'-0"
16
2 1
B
27
20
Print & Mail Room
A
Rear Exit 1
2
3
4
6
7
8
9
Mechanical closet for Chimney Cooling Pipes & HVAC Risers
VAV Supply Air Riser
1
2
3
4
5
6
7
Elevator Shaft
03
17 x 8 1/2" = 12'-0"
8
Fire-rated Egress Stairwell With exterior exit 17
16
13
15
14
11
12
9
10
16
ARCH zilla
VAV Return Air Riser
16
Electrical Risrer
Return & Supply Air Risers
Womans Restroom
Plumbing Wall
H
Janitors Closet
14
ADA Accessible Bathroom
18
15
Womans Restroom
Mens Restroom
Mens Restroom
13
G
Return & Supply Air Risers
Service Core Detail
05
17 x 8 1/2" = 12'-0"
04
7
6
5
4
3
2
1
1
3
5
6
2
7
F 4
17 x 8 1/2" = 12'-0"
8
10
9
11
12
14
13
15
17
16
8 16
17
15
9
11
14
12
10
13
Breaker Box E
18 17 16 15 14 13 12 11 10
D
9
8 7 6
4 3
18 x 8" = 12'-0"
5
2 1
Office Space
18 17 16 15 14
C
13 12 11 10
9
8 7 6
4 3
18 x 8" = 12'-0"
5
2 1
B
13
19
A
7
8
9
Mechanical closet for Chimney Cooling Pipes & HVAC Risers Switch Gear Room
04
7
6
4
Electrical Breaker Box
5
Elevator Shaft
17 x 8 1/2" = 12'-0"
8
9
10
12
11
Fire-rated Egress Stairwell
ARCH zilla
6
14
4
13
3
3
2
2
1
15
Central Walkway Stairs
14
1
Electrical Riser
18
17
Egress Stariwell
19
20
16
Second Floor Plan
J
Fifth Floor Plan
Womans Restroom
02
Kitchen
H
18 17
Supply & Return Air Risers
16 15 14 13 12 11 10
01
12 9
G
22
Switch Gear Room
8
21
7 6 5 4 3
18 x 8" = 12'-0"
Mens Restroom
ADA Accessible Bathroom
Plumbing Wall
J
Breaker Box
2 1
Service Core Detail
11
17 x 8 1/2" = 12'-0"
10
Electrical Riser
7
6
5
4
3
2
1
1
3
2
4
5
7
6
F 17 x 8 1/2" = 12'-0"
8
9
10
11
13
12
14
15
17
16
8 17
16
15
14
9
11
13
12
10
Stairwell
E 09
02
Central Walkway Stairs D
Restaurant
C
01
21
B
A
1
2
3
4
6
7
8
9
VAV Return Air Riser Elevator Shaft
1
2
3
4
5
6
7
VAV Supply Air Riser
11
17 x 8 1/2" = 12'-0"
8
Fire-rated Egress Stairwell
17
16
15
14
13
11
12
9
10
West
ARCH zilla
Mechanical closet for Chimney Cooling Pipes & HVAC Risers
J
Cooling Plant
Water Pumps
Boiler
H
Air Handeling Unit
G
Exhaust Air
Return & Exhaust Air Risers
East Breaker Box & Transformer Switchboard 04
17 x 8 1/2" = 12'-0"
04
5
7
6
4
3
2
1
2
1
4
3
6
5
7
F 17 x 8 1/2" = 12'-0"
8
10
9
12
11
13
15
14
17
16
8 17
16
9
11
15
14
13
10
12
Dry-Type Transformer
Dry-Type Transformer E
West Breaker Box & Transformer Switchboard D
C
B
J
A
H
9
Elevator Penthouse
G
Chimneys
12
13
17 x 8 1/2" = 12'-0"
7
6
5
4
3
2
1
F 1
Cooling Towers
6
17 x 8 1/2" = 12'-0"
8
9
10
12
11
13
15
14
17
17
16
15
9
11
10
13
14
12
16
E
Roof Access
D
ARCH zilla
8
2
7
4
6
3
4
5
3
7
2
Floor Plan_Roof
1
8
Floor Plan_Basement
Return Air
C
B
A
1
2
3
4
6
7
8
9
System_Structural -
Steel Beam Open Web Joist
-
Footings
ARCH zilla
Square Steel Column
VAV Terminal
Sizing of Equipment
-16 in Plumbing wall
Chiller
Return Air Duct
Air Handling Inspection Unit
Return Air Exhaust Supply Air Intake Cooling Plant
Boiler
ARCH zilla
Mechanical_Variable Air Volume
Cooling Tower
-450 sq. ft. Boiler and chilled water plant -85 sq. ft. Cooling tower -30,000 cmf -18 sq. ft. main return ducts -30 sq. ft. branch supply/ return -850 sq. ft. Fan room -80 sq. ft. Fresh air louvers -65 sq. ft. Exhaust louvers -Transformer & switchgear room-30’ x 30’
01
17 x 8 1/2" = 12'-0"
8
16 15 14 13 12 11 10
01
12 9
22 8
21
7 6
3
18 x 8" = 12'-0"
5 4
2
10
11
17 x 8 1/2" = 12'-0"
7
6
5
4
3
2
1
1
3
2
1
5
7
6
5
4
2
1
2
4
3
6
5
7
1
03
17 x 8 1/2" = 12'-0"
3
19
20
17
4
13
18
7
16
02
6
14
17 x 8 1/2" = 12'-0"
8
8
10
9
11
14
13
16
15
17
17
16
15
9
11
10
14
13
12
12
10
9
11
13
12
15
14
17
16
8 17
16
9
11
13
12
10
15
14
16
5th Floor plan
1st Floor Plan
18
15
14
11
09
18 17 16 15 14 13 12 11 10
9
8 7 6
4 3
18 x 8" = 12'-0"
5
2 1
27
7
6
5
4
3
17 x 8 1/2" = 12'-0"
8
HVAC Sizing
12
14
10
9
13
11
16
15
17
8 17
15
16
9
11
12
10
14
13
ARCH zilla
04
Air Handling Sizing
04
17 x 8 1/2" = 12'-0"
2
1
1
3
2
5
4
7
Return Air
Basement Floor Plan
6
Supply Air
Plumbing_Detail
System_Plumbing
Waste Hot and Cold Water
Sink Urinal
Chiller Boiler
ARCH zilla
Toilet
Utility_Electrical Horizontal Trays
Vertical Shaft
Transformer
Switch Gear
ARCH zilla
Circuit Breaker
ARCH zilla Section Perspective_Envelope System
ARCH zilla December
June
EcoTect Sun Studies
ARCH zilla
Annual Utility Consumption by End Use
Monthly Utility Consumption by End Use
Updated DProfiler Analysis
Personal office (100%) 11/27/2012 2:53 AM
Building Geometry Data Gross Floor Area: Building Shell Area: Ventilated Volume: Glazing Ratio:
57558.75 48790.30 610230.86 0
Building Shell Performance Data Air Leakage: 1.04 Outer Heat Capacity: 23.99*10^-4
sq ft sq ft cu ft % ACH Btu/sq ft,F
Heat Transfer Building Shell Average: Floors: External: Underground: Openings:
U value 1.43 1.98 - 1.98 0.07 - 4.16 0.08 - 0.10 0.37 - 1.14
[Btu/sq ft,F,hr]
Specific Annual Demands Net Heating Energy: Net Cooling Energy: Total Net Energy:
23.55 6.34 29.89
kBtu/sq fta kBtu/sq fta kBtu/sq fta
50.32 20.43 38.13 1.45 4.41
Energy Consumption: Fuel Consumption: Primary Energy: Operation Cost: CO2 Emission:
Energy Consumption by Targets
Key Values
Target Name
Cost
Primary
Emission
kBtu/a
USD/a
kBtu/a
lb/a
Heating Cooling Hot Water Generation Ventilation Fans Lighting & Appliances
Total:
CO2
Quantity 1320089 355458 682944 0 462020
0 0 7581 0 16248
0 0 751238 0 1386062
0 0 95311 0 64479
2820513
23830
2137301
159791
Energy Source Name
Quantity
Environment Natural Gas Electricity
kBtu/sq fta kBtu/sq fta kBtu/sq fta
21% 100%
[kBtu]
USD/sq fta
79%
100%
0
500000
1000000
1675548
lb/sq fta Energy Quantities
Energy Costs
CO2 Emission
16
Source Type
Source Name
Renewable Fossil Secondary
Quantity
Cost
kBtu/a
USD/a
Environment Natural Gas Electricity
Total:
Energy Quantities
32
CO2 Emission 24
lb/a
1675548 682944 462020
NA 7581 16248
0 95311 64479
2820513
23830
159791*
24
24
[%]
[%]
60
68
60
40 40
[%]
[%] 60
Supplied Energy per Month
32 32
40
[%]
13
16
16
47 68
CO2 Emission
Energy Costs
[%]
480.9 400 300 200 100
Jan
Feb
Mar
Apr
May
Jun
Jul
Aug Sep
Oct
Nov Dec
0 [MBtu] 0 100 200
60
300
60
400
68
Emitted Energy per Month * This amount of CO2 is absorbed in one year by 0.9 acres (roughly equivalent to 0.7 football fields) of tropical forest.
Lighting and Equipment
Transmission
Internal Heat Gain
Infiltration
Solar Gain
Natural Ventilation
Hot Water Generation
Hot Water
Natural Heat Source
Natural Cooling
ARCH zilla
Energy
Monthly Energy Balance
Energy Consumption by Sources
ArchiCAD Energy Analysis
General Project Data Location: Primary Operation Profile: Evaluation Date:
Energy
Structural System and Construction Type
Structural_Wall Section Shade Device
For our project we decided to go with steel structure, so that less space is taken up. A Joist system is being used to have fewer columns. The Joist spans a max distance of 40 feet with a depth of 2 feet. The Structural steel beams we use span a max distance of 12 feet 6 inches with a depth of 6 inches. We use Struc tural steel tube columns which are 4 x 4 inches 12 feet tall. The precast concrete slab is a solid flat slab, with a span of no more than 12 feet the slab only needs to be 4 inches thick. We decided with a thicker slab to be able to support more weight. Structural steel beams - Span of 12’ 6”, depth 6” Open-web steel joists - Span 40’, depth 24” Precast concrete slabs – solid flat slab - Span 12’6”, depth 10”
8”Concrete Slab
Fire Escape -There are two fire escapes located at the base of each two hour fire-resistance rated enclosed stairwell, and one hour fire rated doors. Fire Extinguishers -Dry Standpipes are located in each stair well along with a hose cabinet on each floor. -All structural members will be equipped with a two hour fire rating.
ARCH zilla
Fire Resistance Strategy
ARCH zilla Prspective