TAYLA SUMMERTON ARCHITECTURE PORTFOLIO SELECTED WORKS 2016-2019
CURRICULUM VITAE REFERENCES 3RD YEAR - ARCHITECTURE
THE INSTITUTE OF CONTEMPORARY ART MODEL CONNECTING SALVOKOP TO THE CITY - URBAN VISION SALVOKOP CIVIC HUB DOCUMENTATION OF AN EXPERIENTIAL DEVICE CZECH REPUBLIC EMBASSY TECHNICAL DRAWINGS - CZECH REPUBLIC EMBASSY
2ND YEAR - ARCHITECTURE
HAMMANSKRAAL COMMUNITY CENTRE NATIONAL PG BISON COMPETITION PROPOSAL PLACE OF KNOWLEDGE JANUS HOUSE
2ND YEAR - LANDSCAPE ARCHITECTURE BROOKLYN MALL URBAN CIRCLE LANDSCAPE
JUNIOR ARCHITECTURAL TECHNOLOGIST
MISCELLANEOUS - JOURNAL ENTRIES, ARTWORKS & SKETCHES
EDUCATION BSC ARCHITECTURE
THE UNIVERSITY OF PRETORIA, SOUTH AFRICA 2018-2019
BSC LANDSCAPE ARCHITECTURE
THE UNIVERSITY OF PRETORIA, SOUTH AFRICA 2016-2017
EPWORTH INDEPENDANT HIGHSCHOOL
INDEPENDANT EXAMINATION BOARD (IEB) EDUCATION 2011-2015 Subjects:
TAYLA ASHLEIGH SUMMERTON 10 MAY 1997 DRIVERS LISCENCE SOUTH AFRICAN
CELL N0: +27 73 669 4853 EMAIL: taysummerton@gmail.com tay_summerton Tayla Summerton
MODULES COMPLETED DESIGN - ARCHITECTURE DESIGN - LANDSCAPE ARCHITECTURE LANDSCAPE ARCHIITECTURE SOIL SCIENCES THEORY OF STRUCTURES CONSTRUCTION ENVIRONMENTAL THEORY HISTORY OF THE ENVIRONMENT DESIGN COMMUNICATION EARTH STUDIES ANCIENT CULTURE STUDIES BUSINESS LAW PROJECT MANAGEMENT GEOMORPHOLOGY OF THE BUILT ENVIRONMENT
Visual Arts Physical Sciences (Chemistry included) Geography Mathematics Core English Home Language Afrikaans First Additional Language Life Orientation Advanced Mathematics (2012-2015)
SKILLS MODEL BUILDING RENDERING REVIT AUTOCAD LUMION ADOBE PHOTOSHOP ADOBE INDESIGN SKETCHUP TIME MANAGEMENT TEAMWORK LEADERSHIP AMBITION
EXPERIENCE GRICE BELLARS ARCHITECTS SHADOWING 2012-2015 DESIGN AND CONSTRUCTION OF A LEMUR PLATFORM STRUCTURE AT LORY PARK ZOO (JOHANNESBURG)
CURRICULUM VITAE - JUNIOR ARCHITECTURAL TECHNOLOGIST
ACHIEVEMENTS 2019
BSC ARCHITECTURE - 3rd year • 3RD PRIZE - CONNECTING SALVOKOP TO THE CITY COMPETITION A collaboration between the City of Aarhus (Denmark) and the City of Tshwane (South Africa) to envision a link between Salvokop and Pretoria Train Station Precinct • CERTIFICATE OF ACHIEVEMENT - Best Portfolio of the STARS Mentorship Programme in the Faculty of Engineering, Built Environment and Information Technology • COMPLETION OF UNDERGRADUATE DEGREE • BOUKUNDE MEDIA PRODUCTION TEAM - UNIVERSITY OF PRETORIA • EBIT STARS ARCHITECTURE MENTOR • 6 DISTINCTIONS
2018
BSC ARCHITECTURE - 2nd year • NATIONAL PG BISON COMPETITION SUBMISSION - 1 of the top 5 proposals of the University of Pretoria • BOUKUNDE MEDIA PRODUCTION TEAM - UNIVERSITY OF PRETORIA • SAT AMERICAN EXAMINATION - PHYSICAL SCIENCE
2017
BSC LANDSCAPE ARCHITECTURE - 2nd year • GOLDEN KEY INTERNATIONAL HONORS SOCIETY • TEACH ME2 TUTOR • 40 HOURS COMMUNITY SERVICE - Design and Construction of a Lemur platform structure for Lory Park Zoo (Johannesburg) • 7 DISTINCTIONS
2016
BSC LANDSCAPE ARCHITECTURE - 1st year
2015 - 2011
• GEOGRAPHY SUBJECT AWARD • ADVANCED MATHEMATICS • LEADERSHIP IN VISUAL ART AND MARKETING • SOUTH AFRICAN MATHEMATICS OLYMPIAD 2ND ROUND - 5 CONSEQUTIVE YEARS • PROVINCIAL HOCKEY, SWIMMING AND ATHLETICS • ADVANCED MODELLING DIPLOMA • PIANO EISTEDDFORD • CIRCUMNAVIGATED MAURITIUS ISLAND BY KAYAK • 26 INDIVIDUAL TRIATHLON SERIES
TRAVEL EXPERIENCE England Germany Netherlands
France Mauritius South Africa
MANIFESTO
EDUCATOR REFERENCE LETTER 27 November 2019
To Whom it may Concern, I had the great pleasure of having Miss Tayla Summerton in our Third Year Design studio this year. With every challenging brief this year Tayla showcased her assiduous design approach through a series of many sensitive, complex drawings and models. Her meticulous drawing and model building skills emulate her consistentlly diligent work ethic. She has been an asset in our studio- she has always treated everyone around her with respect and worked well with all her fellow students. Tayla shall be a valuable member and contributor to any environment she is placed in. As one of our top achievers in ONT300 this year, Tayla has undoubtedly a wonderful exciting future ahead in architecture.
Sincerely
Tessa Van der Walt Studio Master: Third Year Tel +27 (0) 71 8700143
REFERENCES Tel +27 (0)12 420 4111 Fax +27 (0)12 420 4555
FURTHER REFERENCES, CERTIFICATES AND DOCUMENTS ON REQUEST.
THE INSTITUTE OF CONTEMPORARY ART MODEL, BOSTON MODEL AT SCALE 1:250
CONNECTING SALVOKOP TO THE CITY - URBAN VISION A COLLABORATION BETWEEN THE CITY OF AARHUS (DENMARK) AND THE CITY OF TSHWANE (SOUTH AFRICA) TO ENVISION A LINK BETWEEN SALVOKOP AND PRETORIA TRAIN STATION PRECINCT.
URBAN VISION MODEL
User-centred and specific programming
Integration
DESIGN STRATEGIES The exploration of a Cultural route was explored, connecting iconic heritage nodes and the precinct to the greater Pretoria region. The design accomodates macro and micro scale cultural activities from mobile street vendors to large historical museums. The project aligns specifically with emerging sustainability and resilience design initiatives to illuminate the connection between sustainability and liveable cities. The project will thus investigate a special category of work that has useful implications for new directions in environmental and urban design thinking.
URBAN VISION MODEL
Spatial Activation
Sustainability
Cultural and Heritage Revival
The objective of the collaboration is to define principles and ideas around several critical projects in our city with the ultimate goal to better conceptualize and predict performance before the tendering/implementation phases start. The objective is to connect the Pretoria CBD and Pretoria Station to Salvokop via a link, which will promote and celebrate a non-motorized transport connection.
MAPPING THE UNMAPPABLE - FURTHER DEVELOPMENT AND EXPLORATION OF THE SALVOKOP PRECINCT
PROCESS
CONCEPT - SHADE. SHELTER. SHADOW.
SECTION A - A THROUGH SITE The objective was to design a multi-functional civic hub for the envisioned future of Salvokop, of which acts as another catalyst that will aid the development of the ‘Connecting Salvokop to Pretoria CBD’ Urban vision. The concept of Shade, Shadow, Shelter, allowed for the exploration of production of space defined by existing site conditions - spatial organisation, appropriated space, scale, activities, culture and identities. Resulting in the creation of space that is locally inspired, grounded, replaces the universal and accommodates diversity and mixed-use spaces.
Sustainability and resilience is explored through passive design principles, energy efficiency, Sustainable material resource use, restored biodiversity and the emotional and physical wellbeing of users. Rainwater harvesting systems Passive ventilation Maximized natural daylighting Daylighting stategies Natural & Local materials Renewable energy systems Solar shading
SECTION B - B THROUGH SITE
SALVOKOP CIVIC HUB A CONTINUATION OF THE SALVOKOP PRECINCT LINK
DOCUMENTATION OF AN EXPERIENTIAL DEVICE INSPIRATION FOR CONCEPTUAL SECTION
CONCEPTUAL SECTION INSPIRATION FORM EXPERIENTIAL DEVICE
EXPERIENTIAL SECTION
CZECH REPUBLIC EMBASSY, ETHIOPIA
FOR THE DEPARTMENT OF ARCHITECTURE OF THE FACULTY OF CIVIL ENGINEERING, CTU IN PRAGUE
The Czech Embassy complex mission is primarily to express the cultural level of the state and the traditions of Czech architecture within the European and the world context of cultural heritage. The programming included a main Embassy building, Consular and visa department, Ambassador’s residence and housing apartments.
MAQUETTE LIGHT EXPLORATIONS
SURROUNDING CONTEXT SKETCHES
EMBASSY MODEL
MAQUETTE LIGHT EXPLORATIONS
EMBASSY MODEL
EMBASSY MODEL
PRODUCED BY AN AUTODESK STUDENT VERSION
Notes GENERAL NOTES: MIXED USE RESIDENTIAL, COMMERCIAL, RETAIL
EXISTING BUILDING
EXISTING BUILDING
EXISTING BUILDING
EXISTING TREE
EXISTING BUILDING
MIXED USE RESIDENTIAL, COMMERCIAL, RETAIL
EXISTING BUILDING
EXISTING BUILDING
EXISTING TREE
EXISTING TREE
EXISTING TREE
MIXED USE RESIDENTIAL, COMMERCIAL, RETAIL
EXISTING BUILDING
EXISTING TREE
EXISTING BUILDING
EXISTING BUILDING
EXISTING BUILDING
DRAWINGS ARE NOT TO BE SCALED FOUNDATIONS TO ALL BOUNDARY WALLS ARE NOT TO ENROACH BOUNDARY. ALL ELECTRICAL AND PLUMBING WORK IS TO BE CARRIED OUT BY A REGISTERED TRADESMAN
EXISTING TREE
EXISTING TREE
EXISTING TREE
EXISTING BUILDING
EXISTING TREE
ALL LEVELS, DIMENSIONS AND STEPS ARE TO BE CHECKED AND VERIFIED ON SITE BEFORE COMMENCING WITH ANY WORK. ANY INDISTINCTNESS OR INDISCREPANCIES MUST IMMEDIATELY BE POINTED OUT TO THE ARCHITECT FOR RECTIFICATION OR EXPLANATION BEFORE ANY CONSTRUCTION CAN COMMENCE.
EXISTING TREE
EXISTING BUILDING
EXISTING TREE
EXISTING TREE
ALL MATERIALS AND CONSTRUCTION MUST COMPLY WITH THE NATIONAL BUILDING REGULATIONS (ACT NO 103 OF 1977) INCLUDING ALL AMENDMENTS AS WELL AS THE BY-LAWS OF THE LOCAL AUTHORITIES.
EXISTING TREE 3500
DRAINAGE NOTES:
15
MH 7
ACCESS CONTROL SECURITY GATE 6200
50
00
D
15772
MAIN ENTRANCE TO SITE
10000
400
LANDSCAPING
TEMPORARY SERVICE & STORAGE AREA 50mm WATE 110mm R SEWE PIPE R PIP E
PROPOSED MAIN EMBASSY - OFFICES
110 SEWER
CONNECTIONS MAIN S E OSED PROP SY - OFFIC S EMBA
NG EXISTI G IN BUILD
ROAD EAST
EXISTING TREE
7500
EXISTING TREE
NEW 110mm PVC DRAIN PIPE TO MUNICIPAL CONNECTION AT MIN 1:60 FALL
DARY
EXISTING BUILDING EXISTING TREE
EXISTING BUILDING
MH 17 NEW MANHOLE MUNICIPA 150MM EXISTING E LIN SEWER
L
LINE
EXISTING TREE EXISTING TREE
LEGEND
MIXED USE -
RESIDENTIAL,
COMMERCIAL, RETAIL
TREE TO BE REMOVED
EXISTING TREES
TOTAL GROSS AREA 3834m² TOTAL NET AREA 3258,9m² (20% CIRCULATION & STRUCTURE)
PROPOSED LANDSCAPING JUNCUS EFFUSUS/ ALOE FEROX
COVERAGE 23% (MAX ALLOWABLE 60%) FAR 0.23 (MAX ALLOWABLE 0.39) HEIGHT 7M
MIXED USE RESIDENTIAL, COMMERCIAL, RETAIL
EXISTING MANHOLE
EXISTING TREE
EXISTING MANHOLE
EXISTING BUILDING
EXISTING BUILDING
61
2360
FIRE HYDRANT
23
FH
EXISTING BUILDING
EXISTING BUILDING
NEW MANHOLE
UNDERGROUND PARKING PROVIDED 26 GROUND LEVEL PARKING PROVIDED 11
EXISTING BUILDING
EXISTING BUILDING
PROPOSED TREES ERYTHRINA LYSISTEMON/ ACACIA XANTHOPHLOE
FIRST FLOOR REPRESENTATIVE SPACES 380m² APARTMENTS 286m²
TOTAL PARKING PROVIDED 37
EXISTING BUILDING
3500
LAWN
BOUN
EXISTING TREE
EXISTING BUILDING
23
10000
4000
EXIS TI BUIL NG DING
EXISTING BUILDING
GROUND FLOOR MAIN EMBASSY 1200m² AMBASSADORS RESIDENCE 370m² VISA & CONSULAR DEPARTMENT 171m² APARTMENTS 284m² WORKFORCE RESIDENCE 213m²
EXISTING TREE
UP
EXISTING TREE
SITE AREA 13780m²
MH 16
POROUS BRICK PAVING - STRETCHER BOND
ALL
OU FOR NB ES BIO GA TUR E UC SED OM SIT STR PO R OLA PRO NE F O7 ERG 1.8M H ST 3967 R P PACE E IT B UP W TIM KET S R MA
146609
VEHICLE & PEDESTRIAN ACCESS
NEW MANHOLE
YW
AR ND
MH 8
WINDOWS AND SIDELIGHTS LOWER THAN 300MM FROM FLOOR 6MM SAFETY GLASS, SLIDING OR FRENCH DOORS 6MM SAFETY GLASS WITH SAFETY INDICATORS.
MIXED USE RESIDENTIAL, COMMERCIAL, RETAIL
JUNCTION BOX
110 SEWER CONNECTIONS
LANDSCAPING
3MM GLASS 4MM GLASS 6MM GLASS
EXISTING BUILDING
EXISTING BUILDING
PIPE WATER PIPE 50mm SEWER 110mm
WALL
5500
LIC
450
ARY
3067
AY
11
MH 15
EXISTING BUILDING
- 0.75 SQM - 1.5 SQM SQM
PRODUCED BY AN AUTODESK STUDENT VERSION
AL
KW
LANDSCAPING
10
PARKING FOR CONSULAR & VISA DEPARTMENT
104235
W
MH 14
PROPOSED CAFE
9
3000
1.2M WIT PROPO H STO SE NE FRD GAB ION LINE OM SITE BOUND
H ROA
EXISTING BUILDING
62
SE
8
3000
NC
7
3000
SOUT
EXISTING TREE
I-E
WORKERS ENTRANCE
EXISTING BUILDING
EXISTING BUILDING
M
D
EXISTING TREE
RECREATIONAL SPACE
DARY
UP UP
SE
EXISTING TREE 4000
7500
3000
TIMBER DECKING
TIMBER DECKING
FH
BOUN
EXISTING TREE
EXISTING TREE
ENTRANCE TO UNDERGROUND PARKING
LO
NEW MANHOLE MH 6
EXISTING TREE
PROPOSED MAIN EMBASSY - ENTRANCE AREAS
MH 5
LANDSCAPING
EXISTING TREE
FF NO RU NEL ER AN AT H W RC RM E O AT ST O W T 20 1: AT P M
3
5
EXISTING TREE
110 SEWER CONNECTIONS
236
PARKING
5500
POROUS BRICK PAVING - STRETCHER BOND
EXISTING MANHOLE ON EXISTING LINE
ENTRANCE TO MAIN EMBASSY
MH 13
IN
PROPOSED LABOR RESIDENCE
6918
00
12
UP
RA
EXISTING TREE
D ED AN OS AR OP UL T PR NS EN CO SA RTM VI PA ES DE FIC OF
D
MA ED OS OP SSY PR BA CES EM FFI -O
EXISTING BUILDING
UP
TO UN RS STAI RGRO UNDE ING PARK
4
RECREATIONAL SPACE
54067
EXISTING TREE
EXISTING TREE
POROUS BRICK PAVING - STRETCHER BOND
PROPOSED APARTMENTS
UP
LAWN
LINE
10162
MH 2
0 0.75 1.5
FH
3000
STAIRS TO UNDERGROUND PARKING
LANDSCAPING
75 WATER PIPE CONNECTED TO MUNICIPAL WATER
GLASS NOTES:
ENTRANCE TO CONSULAR & VISA DEPARTMENT
MH 12
7500
L
NE
MH 4
LAWN
AN
MH 3
UP 7801
UP
EXISTING TREE
CH
110 SEWER CONNECTIONS
ENTRANCE TO AMBASSADORS RESIDENCE
POROUS BRICK ROAD PAVING - HERRINGBONE PATTERN
450mm STORM WATER PIPE
UP
1.2M EXISTING CLAY BRICK BOUNDARY WALL
ER
EXISTING TREE
AT
PROPOSED APARTMENTS
3000
EXISTING TREE
3
UP
EXISTING TREE
EXISTING TREE
POROUS BRICK PAVING - STRETCHER BOND
PROPOSED CONSULAR AND VISA DEPARTMENT - ENTRANCE AREAS
W
FH
PROVIDE I.E.'S TO ALL BENDS AND JUNCTIONS WITH SUITABLE MARKERS AT GROUND LEVEL. MINIMUM FALL TO ALL DRAIN PIPES TO BE 1:40 PROVIDE APPROVED RESEAL TRAPS TO ALL WASTE FITTINGS. PROVIDE A.E. TO FOOT OF ALL SOIL STACKS. I.E.'S TO WASTE PIPES TO BE FULLY ACCESSIBLE AT ALL TIMES. ALL DRAIN PIPES PASSING UNDER BUILDING OR FOOTINGS TO BE ENCASED IN CONCRETE OF MINIMUM 100MM THICKNESS ALL ROUND PIPE.
15917
LANDSCAPING
EXISTING TREE
PROPOSED AMBASSADORS RESIDENCE
PUBLIC SQUARE
2600
EXISTING TREE
MH 1
POROUS BRICK PAVING - STRETCHER BOND
UP
UP
UP
5500
2
2300
300
PROPOSED APARTMENTS 6811
6941
EXISTING BUILDING
6190
14828
EXISTING TREE
8757
EXISTING BUILDING
TIMBER DECKING
5755
1.8M PROPOSED GABION BOUNDARY WALL WITH STONE FROM SITE
PROPOSED REPRESENTATIVE SPACES
DING BUIL
8174
EXISTING BUILDING
1 PARKING
EXISTING BUILDING
BUILDING LINE 110 SEWER CONNECTIONS
110 SEWER CONNECTIONS
TIMBER REFUGE REMOVAL DECKING AREA 6 PARKING
NEW MANHOLE MH 11
MH 10
5
45 SE 0x5 AT 00 IN mm G PL CLA AN Y TE BR R IC FO K R PU B
LANDSCAPING
16297
EXISTING TREE
EXISTING TREE
EXISTING TREE
MH 9
EXISTING TREE
450mm STORM WATER PIPE
10038
EXISTING BUILDING
7496
EXISTING BUILDING
45
EXISTING
WATER METER WITH TREE CONNECTING VALVES ACCESSIBLE BY MUNICIPALITY
SE P M C RO I-E NC V ON PO D ISA SU SED LOS ED LA O EPA W R FF R AL A IC TM KW ND ES E AY NT -
12000
5500
ACCESS CONTROL SECURITY GATE
ALL PLUMBING AND DRAINAGE WORK AND INSTALLATION OF SANITARY FITTINGS TO COMPLY WITH THE RELEVANT LOCAL AUTHORITY BYE-LAWS, REGULATIONS AND REQUIREMENTS.
EXISTING BUILDING
BOUNDARY LINE
95605
SERVICE VEHICLE ACCESS 5000
2364
University of Pretoria Department of Architecture Subject
SITE DEVELOPMENT PLAN 1:500
KON 320 - Assignment 1 Project Title 5942 2567
N
NGL
NORTH ELEVATION 1:500
NGL
SOUTH ELEVATION 1:500
Site Development Plan
Name
4368
3500
NGL
EAST ELEVATION 1:500
TECHNICAL DRAWINGS OF CZECH REPUBLIC EMBASSY
Tayla Summerton
Student Number
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
7000
SECONDARY ENTRANCE TO SITE
NORTH ROAD
WEST ELEVATION 1:500
NGL
Date of Submission
Reference Number
1-1
16027338 12-08-2019 Number of Drawings in Set
2
Course
BSc.Arch Drawing Number
1
300mm TREADS 170mm RISERS 1200mm BALUSTRADE HEIGHT
UP
A
GRAVEL TO ALLOW FOR INFILTRATION
AIN TO ER DRNEL MWAT AN STOR TER CH WA
7
13 14 15 16 17 18 19 20
LANDSCAPING
GENERAL NOTES:
B
DOWNPIPE P
TE
LANDSCAPING
-S
ER
TH
EA
m
0m
6
17
W
D1
POROUS HERRINGBONE BRICK PATTERN PAVING
ALL LEVELS, DIMENSIONS AND STEPS ARE TO BE CHECKED AND VERIFIED ON SITE BEFORE COMMENCING WITH ANY WORK.
D
AREA 15m²
800mm ABOVE GROUND FLOOR LEVEL
W
1
ALL MATERIALS AND CONSTRUCTION MUST COMPLY WITH THE NATIONAL BUILDING REGULATIONS (ACT NO 103 OF 1977) INCLUDING ALL AMENDMENTS AS WELL AS THE BY-LAWS OF THE LOCAL AUTHORITIES.
C
40
AMBASSADORS ENTRANCE
36
STAIRCASE TO BASEMENT PARKING/ STORAGE
LIFT TO BASEMENT
ELECTRICAL DISTRIBUTION BOARD
35
W
1
1
W
37
5
POROUS HERRINGBONE BRICK PATTERN PAVING
DOWNPIPE
AMBASSADORS OFFICE
37
D1
D1
AREA 30m²
SECRETARIAT
36
DOWNPIPE
AREA 20m²
DRAINAGE NOTES:
R OF
T
D1 04
W2 01
D1 05
W2
D1
02
AREA 20m²
WC
W2 03 W2
whb
SH
07
D1
W2
04
05
TIMBER DECKING SPILLOUT SPACE
whb
08
ST
CU
VI
M
NG
M
NG
FI
m
0m
17
24
-S
ER
TH
EA
W
P
1
20
22 D1
220 x 330mm STRUCTURAL COLUMNS TO ENGINEERS SPECIFICATIONS.
TO AIN L R D NE N ER A AT CH W R M E R T O WA T S
19
23
D1
450mm x 400mm HIGH CLAY BRICK PLANTER WALL
FH
20
CAFETERIA
0
AREA 20m²
W1
20
19
W1
W1
AREA 25m²
21
OFFICE
W1
D1 28
W1
R
D2 07
CUSTOM FIT
WORKSHOP ROOM
D1 34
E
OV
AB
W1 02
W1 01
SHOWER W1 03
D1 33
OF
RO
SERVICE DUCT
OF
SUMP
UP
DOWNPIPE
10
DOWNPIPE
N 8
9
11
12
W1
D1 27
W1
STOREROOM
SHELVING
AREA 25m²
W1
OFFICE
SHELVING
W1
AREA 25m²
1 2 3 4 5 6 7 8 9 10 11 12 13 14
D1 24
W1
D1 25 W1
WORKSHOP ROOM
W1
AREA 20m²
W1
05 W1
06
DOWNPIPE
19
10
University of Pretoria Department of Architecture
09
18
08
Subject
KON ASSIGNMENT 2
17
07
AREA 25m²
OFFICE
13
12
11
CUSTOM FIT
FIRE STAIR CASE 300mm TREADS 170mm RISERS W1 04
D1 26
CUSTOM FIT
COURTYARD SPACE
AREA 30m²
SHOWER
230mm CONCRETE WALLS UNFINISHED
S
ELECTRICAL DISTRIBUTION BOARD
WC WITH SHOWERS
Project Title
16 15
Description
NO. Date
AREA 50m²
D1 32
E
LIN
WC
14
AREA 25m²
TAP
WC
Revision Schedule
W1
D1 23
D1 31
PRINTING ROOM
Q
15
D1 30 D1 22
whb
LAUNDRY/ DRYING ROOM
16
TO CUS G LVIN SHE
SHELVING
AREA 30m²
DUMPSTER BIN
17
M FIT
D1 29
whb
DUMPSTER BIN
W1
AREA 15m²
AREA 25m²
SEMI-OPEN WALKWAY WITH PERGOLA STRUCTURE ABOVE
230 x 330mm STRUCTURAL CONCRETE COLUMNS TO ENGINEER SPECIFICATION
AREA 10m²
P
18
ARCHIVE ROOM
OFFICE
230mm CONCRETE WALLS UNFINISHED
CLOAKROOM
POROUS HERRINGBONE BRICK PATTERN PAVING
W1
AREA 25m²
DOWNPIPE
REFUSE AREA
W1
OFFICE
AND 1ST FLOOR
D1 21
PROPOSED TREES ERYTHRINA LYSISTEMON/ ACACIA XANTHOPHLOEM
P
UP
FHR
21
T
AF SH
GROUND FLOOR LEVEL
TE
AL
300mm TREADS 170mm RISERS
IC TR EC
M
SECONDARY WORKERS ENTRANCE
4321
170mm WEATHER-STEP
700mm ABOVE NGL
R-S
EL
whb
06
WC
15
A HV
HE
17
AREA 9m² TILES
whb
DOWNPIPE
LANDSCAPING
AT
D1
WC
22
S PE EM RG I-O OL PEN A ST WA RU LK CT WA UR Y E WIT AB H OV E LIFT TO BASEMENT
0m
18
D1
D2 m WE
16
WC
R FO
17
1
D1
D1
L
CT DU & IA FT TER A E SH F C CA
W
A
ALL 320mm AND 220mm CONCRETE WALLS TO INCLUDE SLIGHT RED PIGMENT.
1
GROUND FLOOR LEVEL
W
AREA 9m²
W
1
2
POROUS HERRINGBONE BRICK PATTERN PAVING
COPIER ROOM
LANDSCAPING
3
TIMBER DECKING SPILLOUT SPACE
11
ALL INTERIOR FLOOR SURFACES TO BE FINISHED WITH CONCRETE SCREED WITH LARGE AGGREGATE OF STONE ON SITE.
VISA & CONSULAR DEPARTMENT
TE
3MM GLASS 4MM GLASS 6MM GLASS
WINDOWS AND SIDELIGHTS LOWER THAN 300MM FROM FLOOR 6MM SAFETY GLASS, SLIDING OR FRENCH DOORS 6MM SAFETY GLASS WITH SAFETY INDICATORS.
4
OUTDOOR TIMBER DECKING
T
D1
3
K
21
T
AREA 16m²
1
DOWNPIPE
O
VI
FI
W
1
2
J
ST
EL
COURTYARD SPACE
O
EL
OFFICE
I
DOWNPIPE
14
SH
10 CU
D1
AREA 25m²
D1
3 17 00m 0m m m TR R E IS A ER DS S
FI
OFFICE
25
T
FHR
- 0.75 SQM - 1.5 SQM SQM
5 G 00m LE RO m VE UN BE L D LO FL W O O R
03
29
1
OFFICE
FI
S PE EM RG I-O OL PEN A ST WA RU LK CT WA UR Y E WIT D1 AB H OV 09 E
06
W
M
NG
0 0.75 1.5
Czech Embassy Building, Addis Ababa Ground Floor Plan
LANDSCAPING
DOWNPIPE
1
Ground Floor Plan Scale 1:100
PROPOSED TREES ERYTHRINA LYSISTEMON/ ACACIA XANTHOPHLOEM
13
Name
14
Tayla Summerton
Student Number
N
Date of Submission
Reference Number
2-1
PRODUCED BY AN AUTODESK STUDENT VERSION
LANDSCAPING
16056150
Course
BSc.Arch Drawing Number
27-08-2019 Number of Drawings in Set
1 2
PRODUCED BY AN AUTODESK STUDENT VERSION
NG
VI
DS EA RS TR E m RIS 0m m 40 0m 15
VI
M
AREA 20m² D1 12
ER AT
D1
W1
WC
D1
W R FO E ION UR CT AT LE FE OL C
O
WC
AREA 20m² TILES
ER AT
ST
EL
O
34
SH
EL
WC
0m m 15 CO °S N L C PA AN RET SS T T E AG OW WA EW AR LL AY DS S A T
ST
SH
GLASS NOTES:
1
CU
NEW 330mm CONCRETE WALL
CU
MEETING ROOM
22
D2
AREA 80m² BRICK PAVING
01
AREA 10m² WC
H W
03
ENTRANCE HALL
DISABLED WC
33
28
whb
1
D1
13
31
02
D1
AREA 15m²
W
D1 W1
RECEPTION
W
ST
D
W
32
E
G
TO AIN L R D NE N ER A AT CH W R M TE R O WA
OFFICE AREA 20m²
M
LU
VO
LE
B OU
27
AREA 30m²
AREA 25m²
1
D2
26
7
PROVIDE I.E.'S TO ALL BENDS AND JUNCTIONS WITH SUITABLE MARKERS AT GROUND LEVEL. MINIMUM FALL TO ALL DRAIN PIPES TO BE 1:40 PROVIDE APPROVED RESEAL TRAPS TO ALL WASTE FITTINGS. PROVIDE A.E. TO FOOT OF ALL SOIL STACKS. I.E.'S TO WASTE PIPES TO BE FULLY ACCESSIBLE AT ALL TIMES. ALL DRAIN PIPES PASSING UNDER BUILDING OR FOOTINGS TO BE ENCASED IN CONCRETE OF MINIMUM 100MM THICKNESS ALL ROUND PIPE.
W
6
FHR
OFFICE
ALL PLUMBING AND DRAINAGE WORK AND INSTALLATION OF SANITARY FITTINGS TO COMPLY WITH THE RELEVANT LOCAL AUTHORITY BYE-LAWS, REGULATIONS AND REQUIREMENTS.
STORMWATER TO BE DRAINED TO WATER CHANNEL AND DRAINED TO BASEMENT STORAGE TANK
LANDSCAPING
VE BO
5
4
FA OO
3
T
05
2
MEETING ROOM
FI
04
02
1
15 14 13 12 11 10
M
NG
D2
UP
STAIRS TO FIRST FLOOR
9
O
VI
AT
AREA 18m²
8
NEW 330mm CONCRETE WALL
D2
SECURITY VESTIBULE
W
EL
LLS WA DS TE RE WAR O NC CO NT T WAY LA mm GE 220 15° S ASSA P
1
2
ST
SH
ER
W
E
39
CU
39
01 TEP
LIN
32
38
TH
EA
m
A
1
D1
-S
DOWNPIPE
KEYPLAN INDICATING EMBASSY BUILDING
F
1
W
W1
AREA 8m²
m 70
1
DRAWINGS ARE NOT TO BE SCALED FOUNDATIONS TO ALL BOUNDARY WALLS ARE NOT TO ENROACH BOUNDARY. ALL ELECTRICAL AND PLUMBING WORK IS TO BE CARRIED OUT BY A REGISTERED TRADESMAN
E
D1
SECURITY OFFICE
D2
1
GROUND FLOOR LEVEL
W
4 3
1
TO AIN DR ER NEL WAT CHAN RM STO WATER
230 x 330mm STRUCTURAL CONCRETE COLUMNS TO ENGINEER SPECIFICATION
ANY INDISTINCTNESS OR INDISCREPANCIES MUST IMMEDIATELY BE POINTED OUT TO THE ARCHITECT FOR RECTIFICATION OR EXPLANATION BEFORE ANY CONSTRUCTION CAN COMMENCE.
38
MAIN ENTRANCE TO EMBASSY BUILDING
W1
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
Notes GENERAL NOTES: ALL MATERIALS AND CONSTRUCTION MUST COMPLY WITH THE NATIONAL BUILDING REGULATIONS (ACT NO 103 OF 1977) INCLUDING ALL AMENDMENTS AS WELL AS THE BY-LAWS OF THE LOCAL AUTHORITIES. ALL LEVELS, DIMENSIONS AND STEPS ARE TO BE CHECKED AND VERIFIED ON SITE BEFORE COMMENCING WITH ANY WORK.
A
B
220mm reinforced concrete wall at 10° slant
C
5000
ANY INDISTINCTNESS OR INDISCREPANCIES MUST IMMEDIATELY BE POINTED OUT TO THE ARCHITECT FOR RECTIFICATION OR EXPLANATION BEFORE ANY CONSTRUCTION CAN COMMENCE.
D
7000
8000
6mm Safety glass skylight with aluminum framing bolted on 76 x 52mm SA pine purlins nailed to SA pine rafters at 1200 c/c
220mm reinforced concrete wall at 10° slant
6mm Safety glass skylight with aluminium framing skewed to 230mm brick parapet wall and sealed at corner with structural silicone
Detail 1
Indigenous grasses with shallow roots Melinis Repens
6mm Safety glass skylight with aluminum framing skewed to 230mm brick parapet wall and sealed at corner with structural silicone
220
Underside of Slab
dpm
3000
Central Courtyard Space Triple Volume
230
200mm reinforced concrete slab with 50mm concrete screed to fall to outlet
D1 01
Gravel from site plastered to 280mm brick wall - feature wall
Office Space
Feature tree Erythrina Lysistemon
Concrete Screed 25m²
8925
04 Roof Level
Top side of Slab
8700
200mm reinforced concrete slab with 50mm concrete screed to fall to outlet
Underside of Slab
100mm Expanded polystyrene insulation faced on both sides with bitupaper, laid with edges butt-jointed on concrete slab
W1 01
Concrete Screed 40m²
Aluminum framed window fixed with mortar to lintel and 230mm brick wall
225
225
740
3MM GLASS 4MM GLASS 6MM GLASS
WINDOWS, SKYLIGHTS AND SIDELIGHTS LOWER THAN 300MM FROM FLOOR 6MM SAFETY GLASS, SLIDING OR FRENCH DOORS 6MM SAFETY GLASS WITH SAFETY INDICATORS. ALL INTERIOR FLOOR SURFACES TO BE FINISHED WITH CONCRETE SCREED WITH LARGE AGGREGATE OF STONE ON SITE. ALL 320mm AND 220mm CONCRETE WALLS TO INCLUDE SLIGHT RED PIGMENT.
1310
6603
800
150mm Compacted Fill
dpc
Stone Aggregate from site for drainage
2000
450 2200
Concrete Screed 20m²
3600
3000
702
Top side of Slab
230 700
280mm Clay brick Cavity wall insulated in cavity
250
01 FFL Basement Floor Level
00 UFFL Basement Floor Level 0
dpm
1300
300
300
3500
Ø110
300
dpm
700
3050
NGL 2250
Semi-basement Tea Room
860
250mm weather step
900
700
3700
225
D1 03
whb
3300
02 Ground Floor Level
2825 Underside of Slab
Aluminum frame door mounted with mortar to lintel and 230mm brick wall in recessed niche
1310
dpc
1500
2100
225 3000
Detail 2
300
700 x 200mm Concrete Footing to Engineer Specification with 280mm clay brick cavity wall with 50mm insulated cavity
- 0.75 SQM - 1.5 SQM SQM
Aluminum framed window fixed with mortar to lintel and 230mm brick wall
Top side of Slab
3200
1300
4000
0 0.75 1.5
200mm Reinforced Concrete slab with 25mm concrete floor screed to fall to balustrade
W1 02
250
280 700
dpm
Underside of Slab
GLASS NOTES:
200mm Reinforced Concrete slab with 25mm concrete floor screed
1300
2330
1800
300
dpm
300
1190
700 x 300mm Reinforced Concrete footing supporting 220mm reinforced concrete wall at 10° slant
Fitted timber cupboards to architect detail specifications
wc
750
Top side of Slab Underside of Slab
700 x 200mm Concrete Footing to Engineer Specification
1300mm high, 4mm thick Safety glass balustrade with aluminum frame skewed to 250mm reinforce concrete slab with 25mm screed to fall to balustrade
2676
01A Basement Floor Level
Mentis Grating 10m²
W2 01
D1 04
5725
1100
Duct
600
1310 1700
2512
Stone Aggregate from site for drainage
Concrete Screed 20m²
2500
265 600
Semi-basement Office Space
dpc
150mm Compacted Fill
896
1700
600
260
NGL
300 610
W2 03
Aluminum framed window fixed with mortar to lintel and 230mm brick wall
200mm Reinforced Concrete slab with 25mm concrete floor screed
Concrete Screed 25m²
Top side of Slab Underside of Slab 4005
2000
800
Ablutions
2200 1300
4260 02A Ground Floor Level
Top side of Slab
PROVIDE I.E.'S TO ALL BENDS AND JUNCTIONS WITH SUITABLE MARKERS AT GROUND LEVEL. MINIMUM FALL TO ALL DRAIN PIPES TO BE 1:40 PROVIDE APPROVED RESEAL TRAPS TO ALL WASTE FITTINGS. PROVIDE A.E. TO FOOT OF ALL SOIL STACKS. I.E.'S TO WASTE PIPES TO BE FULLY ACCESSIBLE AT ALL TIMES. ALL DRAIN PIPES PASSING UNDER BUILDING OR FOOTINGS TO BE ENCASED IN CONCRETE OF MINIMUM 100MM THICKNESS ALL ROUND PIPE.
3000
200mm Reinforced Concrete slab with 25mm concrete floor screed
5950
03 First Floor Level
D1 02
1300mm high, 4mm thick Safety glass balustrade with aluminum frame skewed to 250mm reinforce concrete slab with 25mm screed to fall to balustrade
1310
1100
1310
750
Office Space
Concrete Screed 25m²
1220
Aluminum frame door mounted with mortar to lintel and 230mm brick wall in recessed niche
250
1200
W1 02
Aluminum framed window fixed with mortar to lintel and 230mm brick wall
1450
230
Meeting Room
3000
1300
630
7400
DRAINAGE NOTES:
230 706
110mm Ground Water Drain to drain water 700 x 200mm Concrete Footing to Engineer Specification
280 706
700 x 200mm Concrete Footing to Engineer Specification
Revision Schedule Description
NO. Date
200mm Reinforced Concrete slab with 25mm concrete floor screed
A 7
UP
Section AA
University of Pretoria Department of Architecture
C D
Subject
5 E
Scale 1:50
KON 320 - Assignment 3
F
4 3
Project Title
2 G
UP
1 H I
Czech Embasy Building, Addis Ababa Section A - A
J K
21
20 0
Name
Tayla Summerton
Student Number
L UP
M
Date of Submission
18
UP
10
Keyplan of Embassy Building N
PRODUCED BY AN AUTODESK STUDENT VERSION
1
B
6
12
Reference Number
16027338 11/07/2019 Number of Drawings in Set
17
C-1
2
Course
BSc.Arch Drawing Number
1
PRODUCED BY AN AUTODESK STUDENT VERSION
Top side of Slab
Underside of Slab
280mm Clay brick Cavity wall insulated in cavity
dpm
600mm high 230mm brick parapet wall with 360 x 330mm concrete coping
03A First Floor Level
250
7660
4000
7945
1300mm high, 4mm thick Safety glass balustrade with aluminum frame skewed to 200mm reinforced concrete slab with 25mm concrete floor screed to fall to balustrade
200mm Planting Soil on 50mm geotextile drainage layer
360 230
1700
1300
1200
2200
Aluminum frame door mounted with mortar to lintel and 230mm brick wall
Indigenous grasses with shallow roots Melinis Repens
Detail 3
600
10455
Underside of Beam
1300
Top side of Slab
4000
04A Roof Level
250 600
10 710
100mm Expanded polystyrene insulation faced on both sides with bitupaper, laid with edges butt-jointed on concrete slab
600 250 600
2400
420 255 600 50
7000
650
600mm high 230mm brick parapet wall with 360 x 330mm concrete coping
220
Top side of Beam
2200
225 601
360
1200
700
1200
200mm Planting Soil on 50mm geotextile drainage layer
DRAWINGS ARE NOT TO BE SCALED FOUNDATIONS TO ALL BOUNDARY WALLS ARE NOT TO ENROACH BOUNDARY. ALL ELECTRICAL AND PLUMBING WORK IS TO BE CARRIED OUT BY A REGISTERED TRADESMAN
ALL PLUMBING AND DRAINAGE WORK AND 6mm Safety glass skylight with aluminum INSTALLATION OF SANITARY FITTINGS TO COMPLY framing bolted on 76 x 52mm SA pine WITH THE RELEVANT LOCAL AUTHORITY BYE-LAWS, purlins nailed to SA pine rafter at 1200 c/c REGULATIONS AND REQUIREMENTS.
4500
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
170mm Planting Soil on 70mm geotextile drainage layer.
710
1495
1500
Aluminum framed window fixed with mortar to 75 x 110mm reinforced concrete lintel and 230mm brick wall
02 Ground Floor Level 3050
2825 Underside of Slab
2500
860
NGL 1200
0
250
Top side of Slab
200mm Reinforced Concrete slab on 50mm binding sand layer with 25mm concrete floor screed
0
dpm 300
300
Ø110
700 x 200mm Concrete Footing to Engineer Specification
700
-20
700 280
1174 1200
2108 471 250
1110
1310
1300mm high, 4mm thick Safety glass balustrade with fixed aluminum frame embedded into 225mm reinforced concrete slab with 25mm screed to fall to outlet.
610
1495
Aluminum framed window fixed with mortar to 75 x 110mm reinforced concrete lintel and 230mm brick wall
2288
100mm PVC downpipe
2323 610
1449
230mm Structural Brick wall of 75x110x210 clay bricks, plastered with 10mm pigmented concrete screed with expansion joints every 8m
ALL MATERIALS AND CONSTRUCTION MUST COMPLY WITH THE NATIONAL BUILDING REGULATIONS (ACT NO 103 OF 1977) INCLUDING ALL AMENDMENTS AS WELL AS THE BY-LAWS OF THE LOCAL AUTHORITIES. ALL LEVELS, DIMENSIONS AND STEPS ARE TO BE CHECKED AND VERIFIED ON SITE BEFORE COMMENCING WITH ANY WORK. ANY INDISTINCTNESS OR INDISCREPANCIES MUST IMMEDIATELY BE POINTED OUT TO THE ARCHITECT FOR RECTIFICATION OR EXPLANATION BEFORE ANY CONSTRUCTION CAN COMMENCE. DRAWINGS ARE NOT TO BE SCALED FOUNDATIONS TO ALL BOUNDARY WALLS ARE NOT TO ENROACH BOUNDARY. ALL ELECTRICAL AND PLUMBING WORK IS TO BE CARRIED OUT BY A REGISTERED TRADESMAN DRAINAGE NOTES: ALL PLUMBING AND DRAINAGE WORK AND INSTALLATION OF SANITARY FITTINGS TO COMPLY WITH THE RELEVANT LOCAL AUTHORITY BYE-LAWS, REGULATIONS AND REQUIREMENTS. PROVIDE I.E.'S TO ALL BENDS AND JUNCTIONS WITH SUITABLE MARKERS AT GROUND LEVEL. MINIMUM FALL TO ALL DRAIN PIPES TO BE 1:40 PROVIDE APPROVED RESEAL TRAPS TO ALL WASTE FITTINGS. PROVIDE A.E. TO FOOT OF ALL SOIL STACKS. I.E.'S TO WASTE PIPES TO BE FULLY ACCESSIBLE AT ALL TIMES. ALL DRAIN PIPES PASSING UNDER BUILDING OR FOOTINGS TO BE ENCASED IN CONCRETE OF MINIMUM 100MM THICKNESS ALL ROUND PIPE.
0 0.75 1.5
- 0.75 SQM - 1.5 SQM SQM
3MM GLASS 4MM GLASS 6MM GLASS
WINDOWS, SKYLIGHTS AND SIDELIGHTS LOWER THAN 300MM FROM FLOOR 6MM SAFETY GLASS, SLIDING OR FRENCH DOORS 6MM SAFETY GLASS WITH SAFETY INDICATORS. ALL INTERIOR FLOOR SURFACES TO BE FINISHED WITH CONCRETE SCREED WITH LARGE AGGREGATE OF STONE ON SITE.
150mm Compacted Fill
Stone Aggregate from site for drainage 01 FFL Basement Floor Level 00 UFL Basement Floor Level 280mm Clay brick Cavity wall insulated in cavity 110mm Ground Water Drain to drain water
ALL 320mm AND 220mm CONCRETE WALLS TO INCLUDE SLIGHT RED PIGMENT. 3600
350 MICRON DAMP PROOF MEMBRANES WITH 100MM OVERLAPS TAPED WITH 48MM GUNPLAS TAPE.
700 x 300mm Concrete Footing to Engineer Specification
280
GENERAL NOTES:
GLASS NOTES:
Aluminum framed window fixed with mortar to 75 x 110mm reinforced concrete lintel and 230mm brick wall
614
610
whb
2304
1449
Sump to collect rainwater from down pipe to collection in water channel
FGL
Aluminum framed window fixed with mortar to 75 x 110mm reinforced concrete lintel and 230mm brick wall 50mm aluminum handrail
Notes
DRAWINGS IN RELATION TO SECTION AA IN DRAWING 3-1.
Weep hole for drainage
1
110 uPVC sewer piping to connect with municipal sewer line at a min fall of 1:60
Section BB
2
Scale 1:50
East Elevation of Embassy Building Scale 1:50
D
40
224
76
100mm perforated uPVC drainage piping in 170mm gravel for drainage
350 micron damp proof membrane with 100mm overlaps
160
Aluminum framed window bloted to wall plate on 230mm brick parapet wall and sealed at corner with structural silicone
00 Ø1
900
90mm Concrete screed fillet
576
100mm uPVC downpipe
100mm Expanded polystyrene insulation faced on both sides with bitupaper, laid with edges butt-jointed on 225mm concrete slab
University of Pretoria Department of Architecture
Indigenous grasses with shallow roots Melinis Repens
40
225
Waterproofing membrane with 100mm end laps, sealed to primed surface to falls by torchfusion on 50mm concrete screed to fall to outlet
600mm high 230mm brick parapet wall with 360 x 330mm concrete coping
360
Subject
10 110 10 110 10
Czech Embassy Building, Addis Ababa Edge Section & Detail Elevation
Detail 1 - Section of Green roof edge
4
Detail 2 - Section of roof connection Scale 1:10
1 layer bitumen counter flashing over 350 micron dpm 170mm Planting Soil on 70mm geotextile drainage layer.
KON 320 Assignment 4 Project no. 4
Project Title
100mm uPVC downpipe 150
10
248
225
225mm reinforced concrete floor slab with 10mm plaster ceiling
250
Scale 1:10
Description
1400
70 50 100 50
90
50
170
710
150
600mm high 230mm brick parapet wall with 360 x 330mm concrete coping
Revision Schedule NO. Date
150
10 110 10 110 10
3
200mm wide x 160mm height aluminum gutter strapped to 76x228 wall plate Steel I-beams bolted to 76 x 228mm SA pine wall plate
1 layer bitumen counter flashing 674
21
Keyplan of Embassy Building Not to scale
228
Galvanized steel angles with weep holes separating gravel from soil
360
216 110
76
158
76
170mm Planting Soil on 70mm geotextile drainage layer.
G
76
76
Indigenous grasses with shallow roots Melinis Repens
6mm Safety glass skylight with aluminum framing bolted on 76 x 76mm aluminium purlins bolted to 8x100x200 steel I-beam at 1600 c/c
Name
Tayla Summerton
Student Number Date of Submission
Reference Number
D-1
16027338 17-10-2019 Number of Drawings in Set
1
Course
BSc.Arch Drawing Number
4-1
PRODUCED BY AN AUTODESK STUDENT VERSION
10
dpc
700 2100
Concrete Screed 20m²
482
50mm copper piping from municipal water to sanitary fixtures
1200
914
Semi-basement Tea Room
20
1400
225mm Reinforced Concrete slab with 25mm concrete floor screed 1700
30
2000
100mm uPVC downpipe 230mm Structural Brick wall of 75x110x210 clay bricks, plastered with 10mm pigmented concrete screed with expansion joints every 8m
1000
750
250
4400
wc
1495
Air brick Aluminum framed window fixed with mortar to 75x110mm reinforced concrete lintel and 230mm brick wall
Top side of Slab
-10
225mm Reinforced Concrete slab with 25mm concrete floor screed
2108
2030
W1 02
Duct
Underside of Slab
Mentis Grating 10m²
Concrete Screed 15m²
40
5725
914
610
Bathroom
Aluminum frame door mounted with mortar to lintel and 230mm brick wall in recessed niche
5950 03 First Floor Level
Top side of Slab
2100
600
W2 01
D1 04
50
740
800
60
1100
1200
PRODUCED BY AN AUTODESK STUDENT VERSION
Brick Course Gauge
70 2000
1300mm high, 4mm thick Safety glass balustrade with fixed aluminum frame embedded into 225mm reinforced concrete slab with 25mm screed to fall to outlet.
1310
1100 1561
50mm aluminum handrail 80
Aluminum frame door mounted with mortar to lintel and 230mm brick wall
900
610
W1 01
600mm high 230mm brick parapet wall with 360 x 330mm concrete coping
1300
Concrete Screed 40m²
100mm Expanded polystyrene insulation faced on both sides with bitupaper, laid with edges butt-jointed on 225mm concrete slab
1300
559
Meeting Room
90
Underside of Slab
2822
1726
Indigenous grasses with shallow roots Melinis Repens
1600
4000
290
350 micron dpm on 50mm thick concrete screed to fall to outlet
8925 04 Roof Level
Aluminum framed window bloted to wall plate on 230mm brick parapet wall and sealed at corner with structural silicone
1605
1200
710
8700
220
600mm high 230mm brick parapet wall with 360 x 330mm concrete coping
400
250
200mm reinforced concrete slab with 10mm pigmented plaster on underside of slab
Top side of Slab
Steel I-beams bolted to 76 x 228mm SA pine wall plate
900
360 290
225
350
0 Ø10
110
220
Detail 1
Steel I-beams bolted to 76 x 228mm SA pine wall plate
100
Indigenous grasses with shallow roots Melinis Repens
6mm Safety glass skylight with aluminum framing bolted on 76 x 76mm aluminium purlins bolted to 8x100x200 steel I-beam at 1600 c/c
610
224
6mm Safety glass skylight with aluminum framing bolted on 76 x 76mm aluminium purlins bolted to 8x100x200 steel I-beam at 1600 c/c
170
120
228
900
130
D
C
Aluminum framed window bloted to wall plate on 230mm brick parapet wall and sealed at corner with structural silicone
477
D
Detail 2
860
PRODUCED BY AN AUTODESK STUDENT VERSION
PRODUCED BY AN AUTODESK STUDENT VERSION
HAMMANSKRAAL COMMUNITY CENTRE LOW BUDGET DEVELOPMENT IN A TOWNSHIP SETTLEMENT IN PRETORIA NORTH
The brief consisted of a low budget community centre development in Pretoria North, consisting of classrooms, ablutions, library space, kitchen and community hall. The structures consists of locally sourced materials and a minimal composition framing extensive public landscaping. Sustainabilty practices are implemented by means of passive ventilation, storm water collection systems and the use of natural lighting. CAFE SEATING
SITE ENTRANCE
SECTION THROUGH CLASSROOM SPACE
GROUND FLOOR PLAN
MAQUETTE PERSPECTIVES
SITE SECONDARY ENTRANCE
NATIONAL PG BISON COMPETITION PROPOSAL A METAMORPHOSIS OF INDUSTRIAL DECAY TO VERDUROUS HERITAGE
THROUGH THE INTEGRATION OF LANDSCAPING AND CORIAN MATERIAL, THE SURROUNDING EXTERIOR SPACES AND INTERIOR SPACES OF THE EXISTING STRUCTURE HARMONIOUSLY LINK. RESULTING IN THE CONNECTION OF THE PUBLIC SIDEWALK TO THE SITE, CREATING A MULTI-USAGE PUBLIC SPACE.
PLACE OF KNOWLEDGE BROOKLYN, PRETORIA
A place of knowledge inspired by the mathematical golden ratio that appears in patterns in nature. Thus exploring the concept of knowledge from the universe - cosmology, the natural environment and metaphysics.
PROPOSED ART GALLERY SPACE
LIBRARY CIRCULATION
The patterns and proportioning informed the design composition, layout and types of knowledge spaces. From contemplative spaces promoting awareness to digital access driven areas. MAQUETTE LIGHT EXPLORATIONS
SITE ENTRANCE RECEPTION THRESHOLD
GROUND FLOOR PLAN
EXTERIOR LIBRARY SPACE
SITE PLAN INTERIOR CIRCULATION SPACE
JANUS HOUSE
Brooklyn, Pretoria
The brief consisted of a residential development consisting of two juxtaposing clients; an extroverted lady with a family and introverted man who enjoys privacy. The two residences on the site explore connection and isolation from each other, through circulation and layout, facilitated around a central courtyard space. The street side property actives the street front with a MAIN ENTRANCE
COURTYARD SPACE
CONTEXT
SITE ENTRANCE
SITE PLAN
STREET ACTIVATION
GROUND FLOOR PLAN
FIRST FLOOR PLAN
BROOKLYN MALL URBAN CIRCLE LANDSCAPE LANDSCAPE ARCHITECTURE PROJECT
An outdoor extension of Brooklyn Mall, rejuvenating and activating the deteriorated Bronkhorstspruit stream into a public urban circle. The restoration of the stream and programmed market spaces surrounding the terraced urban circle allow for passive surveillance and maintenance of the area. Promoting a safe and walkable site connecting the residential communitiy to Brooklyn mall.
URBAN CIRCLE SKETCH PLAN
CIRCULATION ROUTE ALONG
PEDESTRIAN STREETSCAPE
MARKET SPACES
TERRACED URBAN CIRCLE
MISCELLANEOUS MATRIC ARTWORKS AND SKETCHES
MISCELLANEOUS JOURNAL ENTRIES, ARTWORKS & DOODLES
MISCELLANEOUS JOURNAL ENTRIES - GRAPHIC ANALYSIS OF ARCHITECT DAVID CHIPPERFIELD’S WORK
THANK YOU FOR YOUR ATTENTION. ANY CRITIQUE, COMMENTS OR QUERIES IS HIGHLY REGARDED.