NetEnrich Rel 1.6 - A3000 Quick Start Guide for Installation & Use of NetEnrich Products in a Simple Workgroup Setting in a LAN Environment
NetEnrich Rel 1.6 A3000 Quick Start Guide Copyright Š 2006 NetEnrich, Inc. All rights reserved.
January 2006
-1-
M PL E
Items Provided by NetEnrich NetEnrich VPM Gateway™ A3000 appliance with power supply cable
NetEnrich VPM Hard Controllers
SA
Cables for NetEnrich VPM Hard Controllers
NetEnrich Rel 1.6 A3000 Quick Start Guide Copyright © 2006 NetEnrich, Inc. All rights reserved.
AC Adapter for NetEnrich VPM Hard Controllers
January 2006
-2-
M PL E
Other Items You Will Need for Installation [Optional] Multi-port Power-overEthernet (PoE) switch - IEEE 802.3af compliant
Adapters to convert from RJ45 to DB9
Multi-port Ethernet switch (may not be needed if you have PoE switch)
NetEnrich Rel 1.6 A3000 Quick Start Guide Copyright © 2006 NetEnrich, Inc. All rights reserved.
Back
Remote Power Control strips (optional) – with Serial port or Network control
SA
CAT5 cables – RJ45 – for Ethernet connection
Front
Physical access to ports of target devices that you want to manage with NetEnrich such as a Windows Server (e.g. Keyboard, Video, Mouse, USB, Serial ports)
Physical access to ports of target devices that you want to manage with NetEnrich such as a Network Switch (e.g. Serial Console port)
January 2006
-3-
M PL E
Other Items That Must Already Exist In Your Network
SA
[Optional] Firewall or DMZ that connects to the external Internet
NetEnrich Rel 1.6 A3000 Quick Start Guide Copyright Š 2006 NetEnrich, Inc. All rights reserved.
January 2006
-4-
M PL E
Network Topology for a Simple Workgroup Scenario to Deploy NetEnrich Remote Administrator
Target Device: KVM on Windows Server Power
NetEnrich Cable
NetEnrich VPM Hard Controller
Remote Control Power Strip (Control via Network)
NetEnrich Cable
Internet/ Internet/ WAN WAN
NetEnrich A3000 Appliance
Firewall/ DMZ
Controller/ Management Network 1
PoE Switch
External Network 0
(if all NetEnrich VPM Hard Controllers are powered using AC adapters, then a regular Ethernet switch may also be substituted here)
SA
NetEnrich VPM Hard Controller
KSKS KSKS SKSK
Target Device: Serial Console on Network Switch
NetEnrich Rel 1.6 A3000 Quick Start Guide Copyright Š 2006 NetEnrich, Inc. All rights reserved.
January 2006
-5-
Physical Installation Steps
•
Step 1: Place the NetEnrich appliance on a rack or on a flat surface. Place the other accessories either on a rack or on a flat surface in physical proximity to each other Step 2a: Identify and organize the networks for the NetEnrich system. The NetEnrich appliance A3000 supports two networks. Each appliance therefore has two network ports: A. The first network port (eth0) hooks up to the External Network 0 – also called the User Access network or External WAN network and typically connects to the public Internet via a firewall or DMZ. B. The second network port (eth1) hooks up to the Controller/Management Network 1 – this is the network where all the NetEnrich VPM Hard Controllers reside.
M PL E
•
External Network 0
Controller Network 1
SA
NetEnrich Appliance - Back Side
NetEnrich Rel 1.6 A3000 Quick Start Guide Copyright © 2006 NetEnrich, Inc. All rights reserved.
January 2006
-6-
Step 2b: Gather the following info using the worksheet below for both
M PL E
networks so that you can configure it at a later time via the serial console menu of the NetEnrich appliance: NetEnrich VPM Gateway™ A3000 Configuration Worksheet Default Value
New Value
WAN External Network (eth0): Hostname:
nems-a3000
Domain Name:
netenrich.com
IP Address:
172.21.11.51
Netmask:
255.255.0.0
Gateway:
172.21.0.1
Primary DNS Server:
206.13.28.12
Secondary DNS Server:
206.13.31.12
SA
LAN Management and Controller Network (eth1): IP Address:
192.168.11.51
Netmask:
255.255.255.0
NetEnrich Rel 1.6 A3000 Quick Start Guide Copyright Š 2006 NetEnrich, Inc. All rights reserved.
January 2006
-7-
M PL E
Step 3A: Connecting NetEnrich VPM Hard Controller to KVM of Target Windows Server and to the Controller/Management Network 1 Power
Remote Control Power Strip (Control via Network)
NetEnrich Cable
PoE Switch
Controller/ Management Network 1
NetEnrich VPM Hard Controller - Back
SA
Target Device: KVM on Windows Server
NetEnrich Rel 1.6 A3000 Quick Start Guide Copyright Š 2006 NetEnrich, Inc. All rights reserved.
NetEnrich VPM Hard Controller - Front
January 2006
-8-
M PL E
Step 3B: Connecting NetEnrich VPM Hard Controller to Serial Console of Target Network Switch and to the Controller/Management Network 1 AC Adapter
Target Device: Serial Console on Network Switch
NetEnrich Cable
Wall Power Outlet
(Use AC Adapter if not using a PoE switch to power the NetEnrich VPM Hard Controller)
Ethernet Switch
Front
Controller/ Management Network 1
Back
SA
Adapter to convert from RJ45 to DB9
NetEnrich VPM Hard Controller - Back
NetEnrich Rel 1.6 A3000 Quick Start Guide Copyright Š 2006 NetEnrich, Inc. All rights reserved.
January 2006
NetEnrich VPM Hard Controller - Front
-9-
Step 3B: (contd.) Serial Console Pin Mappings
M PL E
NetEnrich Controller - Serial-1 Cable (RJ-45) Pin-Outs NetEnrich Serial-1 Cable UART Signal Function (RJ-45) Pin-Out 1 CTS Clear To Send 2 DSR Data Set Ready 3 RD Received Data 4 SG Signal Ground 5 DCD Data Carrier Detect 6 TD Transmitted Data 7 DTR Data Terminal Ready 8 RTS Request To Send
Front
Back
NetEnrich Controller - Serial-2 Cable (RJ-45) Pin-Outs NetEnrich Serial-1 Cable UART Signal Function (RJ-45) Pin-Out 3 RD Received Data 4 SG Signal Ground 6 TD Transmitted Data
SA
DTE Adapter Wiring and Pin-Ins for target DTE devices (e.g. Computers, Terminals) that conform to the Yost Serial Device Wiring Standard Target DTE Device Pin-In Alternatives Signal Function RJ-45 Pin-In DB9 Pin-In DB25 Pin-In Pin Color CTS Clear To Send 8 5 1 Blue DCD Data Carrier Detect 1 8 2 Orange RD Received Data 2 3 3 Black SG Signal Ground 5 7 4 Red SG Signal Ground 5 7 5 Green TD Transmitted Data 3 2 6 Yellow DTR Data Terminal Ready 4 20 7 Brown RTS Request To Send 7 4 8 White DSR Data Set Ready 6 6 RI Ring Indicator 9 22 -
NetEnrich Rel 1.6 A3000 Quick Start Guide Copyright Š 2006 NetEnrich, Inc. All rights reserved.
January 2006
DCE Adapter Wiring and Pin-Ins for target DCE devices (e.g. Modems, Printers) that conform to the Yost Serial Device Wiring Standard Target DCE Device Pin-In Alternatives Signal Function RJ-45 Pin-In DB9 Pin-In DB25 Pin-In Pin Color CTS Clear To Send 8 5 8 White DCD Data Carrier Detect 1 8 7 Brown RD Received Data 2 3 6 Yellow SG Signal Ground 5 7 5 Green SG Signal Ground 5 7 4 Red TD Transmitted Data 3 2 3 Black DTR Data Terminal Ready 4 20 2 Orange RTS Request To Send 7 4 1 Blue DSR Data Set Ready 6 6 RI Ring Indicator 9 22 -
-10-
M PL E
Step 4: Connecting NetEnrich Appliance to Controller/Management Network 1 and External Network 0
Internet Internet // WAN WAN
Firewall/ DMZ
External Network 0
Ethernet Switch
Controller Network 1
SA
NetEnrich Appliance - Back Side
NetEnrich Rel 1.6 A3000 Quick Start Guide Copyright Š 2006 NetEnrich, Inc. All rights reserved.
January 2006
-11-
Step 5: Connecting to and Using the NetEnrich system 1.
Power up the NetEnrich VPM Gateway appliance and wait for the appliance to boot up. 2. Power up the NetEnrich VPM Hard Controllers via PoE or AC adapter. 3. Connect a laptop or PC to the External Network 0, and assign it a static IP address: 172.21.11.100 and Netmask: 255.255.0.0 4. If you need to change the preset network configuration settings on the NetEnrich appliance(s) you can either access the administration console webpage at https://172.21.11.51:8443 or use the serial port access with settings 115200,8,N,1 using VT100 to make the modifications. Login with username “admin” and password “admin”. -- NOTE: FOR SECURITY REASONS, PLEASE CHANGE THE PASSWORD ASAP! 5. Connect to the NetEnrich VPM Gateway using a web browser within the External Network 0, and point it to https://172.21.11.51/nems (username: nems; password: nems) or use the changed settings applied in above step 4 -- NOTE: FOR SECURITY REASONS, PLEASE CHANGE THE PASSWORD ASAP! 6. Configure and create objects – Companies, Users, Roles, Controllers, Devices, Device Groups, Permissions 7. Refer to the NetEnrich VPM Gateway Installation Guide section for more details on installation. For further information, please contact NetEnrich at support@netenrich.com
NetEnrich Rel 1.6 A3000 Quick Start Guide Copyright © 2006 NetEnrich, Inc. All rights reserved.
January 2006
-12-