Harmonic Solutions HarmonicGuard® Solution Center
• TCI’s expertise in an easy-to-use online sizing tool • Apply multiple technologies to compare their impact on your system THD & power factor • Determine IEEE-519 compliance
300
HarmonicGuard® Active (HGA) Filter
• Reduce current harmonic distortion to less than 5% allowing you to meet IEEE-519 specifications • Lower your energy bills by improving the power factor and overall efficiency of your system • Easily monitor performance & remotely control the HGA with one of our communications options
Amps
100 0 -100 -200 -300
0
5
10
15
20
Time (ms)
Without HGA
25
30
35
40
Injection Current
300 200 100
Amps
• Save money and space: a single bus-applied HGA can correct harmonics for multiple loads
200
0 -100 -200 -300 0
5
10
15
20
25
30
35
40
30
35
40
Time (ms)
With HGA
300
HarmonicGuard® Passive (HGP) Filter
• Meet IEEE-519 specifications and improve power factor & overall efficiency of your system • Lower your energy bills by reducing harmonic current losses • Save time: detect and repair blown fuses faster with the Fuse Monitor
Amps
100 0 -100 -200 -300 0
5
10
15
20
25
Time (ms)
Without HGP 300 200 100
Amps
• Limit current harmonic distortion to less than 5% with background voltage distortion as high as 5%
200
0 -100 -200 -300
0
With HGP
5
10
15
20
25
30
35
Time (ms)
KDR/KLR Line Reactor
• Extend your drive uptime by reducing the likelihood of the drive tripping • Protect other equipment on the same bus from operational issues caused by voltage distortion • Reduce overheating issues due to harmonic currents TCI, LLC www.transcoil.com
W132 N10611 Grant Drive Germantown, WI 53022 USA
Toll Free: 800-824-8282 P: 414-357-4480 F: 414-357-4484
40
®
Motor Protection Solutions MotorGuardTM Sinewave Output Filter (for cable leads up to approximately 15,000 ft.)
• Greatly extend the life of your motor and cable runs through reduction of motor noise, vibration and heat
1500 1000
Volts
500
• Increase productivity and reduce operating costs • Universal acceptance covers a wide range of applications
0 -500 -1000 -1500
0
5
10
15
20
Time (ms)
25
30
35
40
Without MotorGuard or MotorShield 1500
MotorShield
TM
Sinewave Output Filter
1000 500
• Protect your motor and cable runs by reduction of motor noise, vibration and heat to improve system performance
Volts
(for cable leads up to approximately 15,000 ft.)
0 -500 -1000 -1500
0
5
10
15
20
Time (ms)
25
30
35
40
With MotorGuard or MotorShield
• Resistor-less design is an ideal solution for fan and pump applications
1500
V1k dv/dt Output Filter
1000 500
• Extend the life of your motor and cable by reduction of harmful voltage spikes due to dv/dt • Protect cable runs and reduce motor heating, noise and vibration
Volts
(for cable leads up to approximately 1,500 ft.)
0 -500 -1000 -1500 0
5
10
15
20
25
30
Time (ms)
Without V1k
35
500 feet
1500 1000
• Prevent motor failure with protection against motor insulation breakdown
Volts
500 0 -500 -1000 -1500 0
With V1k
5
10
15
20
Time (ms)
25
30
35
500 feet
High Frequency Noise Solutions KRF EMC Filter
• Filter EMI/RFI noise caused by power switching devices • Prevent interference between automated lighting circuits, security cameras, and other critical electronics on your system TCI, LLC www.transcoil.com
W132 N10611 Grant Drive Germantown, WI 53022 USA
Toll Free: 800-824-8282 P: 414-357-4480 F: 414-357-4484