Weatherford W Series Pumps

Page 1

Pump and Fluid Systems

W60 Triplex Pump Pump Specifications Rated (HP, kW)

60

45

Stroke length (in., mm)

3

76.2

W60H

5,000

345

W60M

3,200

221

Maximum discharge pressure (PSI, Bar)

W60L Rated rod load (lb, kg)

1,500

103

4,750

2,155

API-674 speed, RPM

400

Maximum speed, RPM

500

Minimum speed, RPM

200

Standard Equipment

Crankshaft dimensions (in., mm) Diameter

3.00

76.2

Length (both sides)

5.12

130

.750 × .375

19 × 9.5

Pump

2.0

7.6

Reducer

1.0

3.8

W60H

1,220

553

• Double extended crankshaft

W60M

1,160

526

• Multiple plunger packing arrangements offered

W60L

1,120

508

Keyway, width × depth (in., mm) Oil capacity (gal, l)

• Aluminum-bronze or duplex stainless steel stuffing boxes

Weight (lb, kg); estimates only Pump

Reducer

350

Mechanical efficiency

• Cast aluminum-bronze, forged duplex stainless steel, or forged carbon steel fluid ends

159 90%

• Various valve designs offered per fluid end style • Tungsten carbide coated plungers over stainless steel base or solid ceramic plungers

Optional Accessories • Weatherford bolt on gear reducers (ratios)

Flange Connections

–– 2.34:1 –– 2.77:1

–– 3.03:1

–– 3.50:1

Pump Model

Discharge Connection Sizes (in., mm)

Suction Connection Sizes (in., mm)

W60H

1.25 (31.8) ANSI 2500 RJ

2.5 (63.5) ANSI 300 FF

• Customized plunger packing arrangements

W60M

1.5 (38.1) API 5000 RJ

2.5 (63.5) ANSI 150 FF

• Complete pump packages

W60L (flanged)

2 (50.8) API 2000 RJ

3 (76.2) ANSI 150 FF

W60L (threaded)

2 (50.8) NPT

3 (76.2) NPT

weatherford.com/pumps

• Packing lubricators

Technical Support pumps@weatherford.com 1-281-252-7867

1

© 2013-2014 Weatherford. All rights reserved.

TIS0110.01


Pump and Fluid Systems

W60 Triplex Pump Performance Ratings Model (standard)

Plunger Diameter (in.)

W60H

W60M

Maximum Pressure PSI

200 RPM GPM

BPD

300 RPM GPM

BPD

350 RPM GPM

BPD

400 RPM* GPM

BPD

450 RPM GPM

500 RPM

BPD

GPM

BPD

1.000

0.0306

5,000

6.1

210

9.2

315

10.7

367

12.2

420

13.8

472

15.3

525

1.125

0.0387

4,780

7.7

266

11.6

398

13.6

465

15.5

531

17.4

598

19.4

664

1.250

0.0478

3,870

9.6

328

14.3

492

16.7

574

19.1

656

21.5

738

23.9

820

1.375

0.0579

3,200

11.6

397

17.4

595

20.2

694

23.1

793

26.0

893

28.9

992

1.375

0.0579

3,200

11.6

397

17.4

595

20.2

694

23.1

793

26.0

893

28.9

992

1.500

0.0688

2,690

13.8

472

20.7

708

24.1

826

27.5

944

31.0

1,062

34.4

1,180

1.625

0.0808

2,290

16.2

554

24.2

831

28.3

970

32.3

1,108

36.4

1,247

40.4

1,385

1.750

0.0937

1,970

18.7

643

28.1

964

32.8

1,125

37.5

1,285

42.2

1,446

46.9

1,606

2.000

0.1224

1,500

24.5

839

36.7

1,259

42.8

1,469

49.0

1,679

55.1

1,888

61.2

2,098

2.000

0.1224

1,500

24.5

839

36.7

1,259

42.8

1,469

49.0

1,679

55.1

1,888

61.2

2,098

2.250

0.1549

1,190

31.0

1,062

46.5

1,593

54.2

1,859

62.0

2,125

69.7

2,390

77.5

2,656

2.500

0.1912

970

38.2

1,311

57.4

1,967

66.9

2,295

76.5

2,623

86.1

2,951

95.6

3,279

2.750

0.2314

800

46.3

1,587

69.4

2,380

81.0

2,777

92.6

3,174

104.1

3,570

115.7

3,967

3.000

0.2754

670

55.1

1,888

82.6

2,833

96.4

3,305

110.2

3,777

123.9

4,249

137.7

4,721

Plunger Diameter (in.)

Liters Per Revolution

Maximum Pressure BAR

1.000 1.125 1.250 1.375 1.375 1.500 1.625 1.750 2.000 2.000 2.250 2.500 2.750 3.000

0.1158 0.1466 0.1810 0.2190 0.2190 0.2606 0.3058 0.3547 0.4633 0.4633 0.5863 0.7239 0.8759 1.0424

345 329 267 220 220 185 158 136 104 104 82 67 55 46

W60L

Model (metric)

Gallons Per Revolution

W60H

W60M

W60L

200 RPM

300 RPM

350 RPM

400 RPM*

450 RPM

500 RPM

LPM

M3/hr

LPM

M3/hr

LPM

M3/hr

LPM

M3/hr

LPM

M3/hr

LPM

M3/hr

23.2

1.4

34.7

2.1

40.5

2.4

46.3

2.8

52.1

3.1

57.9

3.5

29.3

1.8

44.0

2.6

51.3

3.1

58.6

3.5

66.0

4.0

73.3

4.4

36.2

2.2

54.3

3.3

63.3

3.8

72.4

4.3

81.4

4.9

90.5

5.4

43.8

2.6

65.7

3.9

76.6

4.6

87.6

5.3

98.5

5.9

109.5

6.6

43.8

2.6

65.7

3.9

76.6

4.6

87.6

5.3

98.5

5.9

109.5

6.6

52.1

3.1

78.2

4.7

91.2

5.5

104.2

6.3

117.3

7.0

130.3

7.8

61.2

3.7

91.8

5.5

107.0

6.4

122.3

7.3

137.6

8.3

152.9

9.2

70.9

4.3

106.4

6.4

124.1

7.4

141.9

8.5

159.6

9.6

177.4

10.6

92.7

5.6

139.0

8.3

162.1

9.7

185.3

11.1

208.5

12.5

231.6

13.9

92.7

5.6

139.0

8.3

162.1

9.7

185.3

11.1

208.5

12.5

231.6

13.9

117.3

7.0

175.9

10.6

205.2

12.3

234.5

14.1

263.9

15.8

293.2

17.6

144.8

8.7

217.2

13.0

253.4

15.2

289.6

17.4

325.7

19.5

361.9

21.7

175.2

10.5

262.8

15.8

306.6

18.4

350.4

21.0

394.2

23.6

437.9

26.3

208.5

12.5

312.7

18.8

364.8

21.9

417.0

25.0

469.1

28.1

521.2

31.3

*API Speed

General Notes 1. Capacities shown are based on 100 percent volumetric efficiency. Actual capacities are lower, based on discharge pressure and fluid compressibility. 2. API-674 and NACE-compliant designs are available; consult Weatherford for details and exceptions to these standards.

weatherford.com/pumps

2

3. For operation below 200 RPM, an auxiliary lubrication system is required. 4. Standard plunger sizes are shown, however other sizes are available upon request.

Š 2013-2014 Weatherford. All rights reserved.

TIS0110.01

Weatherford products and services are subject to the Company’s standard terms and conditions, available on request or at weatherford.com. For more information contact an authorized Weatherford representative. Unless noted otherwise, trademarks and service marks herein are the property of Weatherford and may be registered in the United States and/or other countries. Weatherford products named herein may be protected by one or more U.S. and/or foreign patents. Specifications are subject to change without notice. Weatherford sells its products and services in accordance with the terms and conditions set forth in the applicable contract between Weatherford and the client.


Pump and Fluid Systems

W80 Triplex Pump Pump Specifications Rated (HP, kW)

80

60

Stroke length (in., mm)

3

76

W80H

5,000

345

W80M

4,270

294

W80L

2,020

139

Maximum discharge pressure (PSI, Bar)

Rated rod load (lb, kg)

6,336

2,874

API-674 speed, RPM

400

Maximum speed, RPM

500

Minimum speed, RPM

200

Standard Equipment

Crankshaft dimensions (in., mm) Diameter

3.00

Length (both sides)

76

5.12

130

.75 × .38

19 × 10

Pump

2.0

7.6

Reducer

1.0

3.8

Keyway, width × depth (in., mm) Oil capacity (gal, l)

• Cast aluminum-bronze, forged duplex stainless steel, or forged carbon steel fluid ends • Aluminum-bronze or duplex stainless steel stuffing boxes

• Tungsten carbide coated plungers over stainless steel base or solid ceramic plungers

Weight (lb, kg); estimates only Pump W80H

1,250

1,572

W80M

1,190

544

W80L

1,150

508

Reducer

350

Mechanical efficiency

• Various valve designs offered per fluid end style

159 90%

Flange Connections

• Double extended crankshaft • Multiple plunger packing arrangements offered

Optional Accessories • Weatherford bolt on gear reducers (ratios)

–– 2.34:1 –– 2.77:1

–– 3.50:1 –– 3.03:1

Pump Model

Discharge Connection Sizes (in., mm)

Suction Connection Sizes (in., mm)

W80H

1.25 (31.8) ANSI 2500 RJ

2.5 (63.5) ANSI 300 FF

• Customized plunger packing arrangements

W80M

1.5 (38.1) API 5000 RJ

2.5 (63.5) ANSI 150 FF

• Complete pump packages

W80L (flanged)

2 (50.8) API 2000 RJ

3 (76.2) ANSI 150 FF

W80L (threaded)

2 (50.8) NPT

3 (76.2) NPT

• Packing lubricators

Technical Support pumps@weatherford.com 1-281-252-7867

weatherford.com/pumps

1

© 2013-2014 Weatherford. All rights reserved.

TIS0109.01


Pump and Fluid Systems

W80 Triplex Pump Performance Ratings Model (standard)

Plunger Diameter (in.)

Gallons Per Revolution

Maximum Pressure PSI

GPM

BPD

BPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

1.250

0.0478

5,000

9.6

328

14.3

492

16.7

574

19.1

656

21.5

738

23.9

820

1.375

0.0579

4,270

11.6

397

17.4

595

20.2

694

23.1

793

26.0

893

28.9

992

W80H

W80M

300 RPM

350 RPM

400 RPM*

450 RPM

500 RPM BPD

1.375

0.0579

4,270

11.6

397

17.4

595

20.2

694

23.1

793

26.0

893

28.9

992

1.500

0.0688

3,590

13.8

472

20.7

708

24.1

826

27.5

944

31.0

1,062

34.4

1,180

1.625

0.0808

3,060

16.2

554

24.2

831

28.3

970

32.3

1,108

36.4

1,247

40.4

1,385

1.750

0.0937

2,630

18.7

643

28.1

964

32.8

1,125

37.5

1,285

42.2

1,446

46.9

1,606

2.000

0.1224

2,020

24.5

839

36.7

1,259

42.8

1,469

49.0

1,679

55.1

1,888

61.2

2,098

2.000

0.1224

2,020

24.5

839

36.7

1,259

42.8

1,469

49.0

1,679

55.1

1,888

61.2

2,098

2.250

0.1549

1,590

31.0

1,062

46.5

1,593

54.2

1,859

62.0

2,125

69.7

2,390

77.5

2,656

2.500

0.1912

1,290

38.2

1,311

57.4

1,967

66.9

2,295

76.5

2,623

86.1

2,951

95.6

3,279

2.750

0.2314

1,070

46.3

1,587

69.4

2,380

81.0

2,777

92.6

3,174

104.1

3,570

115.7

3,967

3.000

0.2754

900

55.1

1,888

82.6

2,833

96.4

3,305

110.2

3,777

123.9

4,249

137.7

4,721

3.250

0.3232

760

64.6

2,216

97.0

3,324

113.1

3,879

129.3

4,433

145.4

4,987

161.6

5,541

3.375

0.3486

710

69.7

2,390

104.6

3,585

122.0

4,183

139.4

4,780

156.8

5,378

174.3

5,975

Plunger Diameter (in.)

Liters Per Revolution

Maximum Pressure BAR

LPM

1.250

0.1810

345

36.2

2.2

54.3

3.3

63.3

3.8

72.4

4.3

81.4

4.9

90.5

5.4

1.375

0.2190

294

43.8

2.6

65.7

3.9

76.6

4.6

87.6

5.3

98.5

5.9

109.5

6.6

W80L

Model (metric)

200 RPM

W80H

W80M

W80L

200 RPM M3/hr

300 RPM LPM

M3/hr

350 RPM LPM

M3/hr

400 RPM* LPM

M3/hr

450 RPM LPM

M3/hr

500 RPM LPM

M3/hr

1.375

0.2190

294

43.8

2.6

65.7

3.9

76.6

4.6

87.6

5.3

98.5

5.9

109.5

6.6

1.500

0.2606

247

52.1

3.1

78.2

4.7

91.2

5.5

104.2

6.3

117.3

7.0

130.3

7.8

1.625

0.3058

211

61.2

3.7

91.8

5.5

107.0

6.4

122.3

7.3

137.6

8.3

152.9

9.2

1.750

0.3547

182

70.9

4.3

106.4

6.4

124.1

7.4

141.9

8.5

159.6

9.6

177.4

10.6

2.000

0.4633

139

92.7

5.6

139.0

8.3

162.1

9.7

185.3

11.1

208.5

12.5

231.6

13.9

2.000

0.4633

139

92.7

5.6

139.0

8.3

162.1

9.7

185.3

11.1

208.5

12.5

231.6

13.9

2.250

0.5863

110

117.3

7.0

175.9

10.6

205.2

12.3

234.5

14.1

263.9

15.8

293.2

17.6

2.500

0.7239

89

144.8

8.7

217.2

13.0

253.4

15.2

289.6

17.4

325.7

19.5

361.9

21.7

2.750

0.8759

74

175.2

10.5

262.8

15.8

306.6

18.4

350.4

21.0

394.2

23.6

437.9

26.3

3.000

1.0424

62

208.5

12.5

312.7

18.8

364.8

21.9

417.0

25.0

469.1

28.1

521.2

31.3

3.250

1.2234

53

244.7

14.7

367.0

22.0

428.2

25.7

489.3

29.4

550.5

33.0

611.7

36.7

3.375

1.3193

49

263.9

15.8

395.8

23.7

461.7

27.7

527.7

31.7

593.7

35.6

659.6

39.6

*API Speed

General Notes 1. Capacities shown are based on 100 percent volumetric efficiency. Actual capacities are lower, based on discharge pressure and fluid compressibility. 2. API-674 and NACE-compliant designs are available; consult Weatherford for details and exceptions to these standards.

weatherford.com/pumps

2

3. For operation below 200 RPM, an auxiliary lubrication system is required. 4. Standard plunger sizes are shown, however other sizes are available upon request.

Š 2013-2014 Weatherford. All rights reserved.

TIS0109.01

Weatherford products and services are subject to the Company’s standard terms and conditions, available on request or at weatherford.com. For more information contact an authorized Weatherford representative. Unless noted otherwise, trademarks and service marks herein are the property of Weatherford and may be registered in the United States and/or other countries. Weatherford products named herein may be protected by one or more U.S. and/or foreign patents. For more information, contact patents@weatherford.com. Specifications are subject to change without notice. Weatherford sells its products and services in accordance with the terms and conditions set forth in the applicable contract between Weatherford and the client.


Pump and Fluid Systems

W100 Triplex Pump Pump Specifications Rated (HP, kW)

100

75

4

102

W100H

5,000

345

W100M

3,180

219

W100L

1,660

114

6,595

2,991

Stroke length (in., mm) Maximum discharge pressure (PSI, Bar)

Rated rod load (lb, kg) API-674 speed, RPM

350

Maximum speed, RPM

450

Minimum speed, RPM

150

Standard Equipment

Crankshaft dimensions (in., mm) Diameter

3.75

95

Length (both sides)

8.31

211

.875 × .438

22 × 11

Pump

5.5

20.8

Reducer

3.0

11.4

Keyway, width × depth (in., mm)

Weight (lb, kg); estimates only

• Tungsten carbide coated plungers over stainless steel base or solid ceramic plungers • Double extended crankshaft

Pump W100H

3,200

1,451

W100M

3,100

1,406

W100L

3,150

1,429

500

227

Mechanical efficiency

• Aluminum-bronze or duplex stainless steel stuffing boxes • Various valve designs offered per fluid end style

Oil capacity (gal, l)

Reducer

• Cast aluminum-bronze, forged duplex stainless steel, or forged carbon steel fluid ends

90%

• Multiple plunger packing arrangements offered

Optional Accessories • Weatherford bolt on gear reducers (ratios)

–– 2.61:1 –– 3.15:1

Flange Connections

–– 3.42:1 –– 3.89:1

–– 4.27:1 –– 5.23:1

• Packing lubricators Pump Model

Discharge Connection Sizes (in., mm)

Suction Connection Sizes (in., mm)

• Customized plunger packing arrangements • Complete pump packages

W100H

1.5 (38.1) ANSI 2500 RJ

3 (76.2) ANSI 300 FF

W100M

1.5 (38.1) API 5000 RJ

3 (76.2) ANSI 150 FF

W100L

2.5 (63.5) API 2000 RJ

5 (127) ANSI 150 FF

Technical Support pumps@weatherford.com 1-281-252-7867

weatherford.com/pumps

1

© 2013-2014 Weatherford. All rights reserved.

TIS0105.01


Pump and Fluid Systems

W100 Triplex Pump Performance Ratings Model (standard)

Plunger Diameter (in.)

Gallons Per Revolution

Maximum Pressure PSI

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

1.250

0.0637

5000

9.6

328

15.9

546

19.1

655

22.3

764

25.5

874

28.7

983

1.375

0.0771

4440

11.6

397

19.3

661

23.1

793

27.0

925

30.8

1057

34.7

1190

W100H

W100M

250 RPM

300 RPM

350 RPM*

400 RPM

450 RPM BPD

1.500

0.0918

3730

13.8

472

23.0

787

27.5

944

32.1

1102

36.7

1259

41.3

1416

1.625

0.1077

3180

16.2

554

26.9

923

32.3

1108

37.7

1292

43.1

1477

48.5

1662

1.750

0.1249

2740

18.7

642

31.2

1071

37.5

1285

43.7

1499

50.0

1713

56.2

1927

1.625

0.1077

3180

16.2

554

26.9

923

32.3

1108

37.7

1292

43.1

1477

48.5

1662

1.750

0.1249

2740

18.7

642

31.2

1071

37.5

1285

43.7

1499

50.0

1713

56.2

1927

1.875

0.1434

2390

21.5

737

35.9

1229

43.0

1475

50.2

1721

57.4

1967

64.5

2212

2.000

0.1632

2100

24.5

839

40.8

1399

49.0

1679

57.1

1958

65.3

2238

73.4

2518

2.125

0.1842

1860

27.6

947

46.1

1579

55.3

1895

64.5

2210

73.7

2526

82.9

2842

2.250

0.2065

1660

31.0

1062

51.6

1770

62.0

2124

72.3

2478

82.6

2832

92.9

3186

2.500

0.2550

1340

38.3

1311

63.8

2186

76.5

2623

89.3

3060

102.0

3497

114.8

3934

2.750

0.3085

1110

46.3

1587

77.1

2644

92.6

3173

108.0

3702

123.4

4231

138.8

4760

3.000

0.3672

930

55.1

1888

91.8

3147

110.2

3777

128.5

4406

146.9

5036

165.2

5665

3.250

0.4309

790

64.6

2216

107.7

3693

129.3

4432

150.8

5171

172.4

5909

193.9

6648

3.375

0.4647

740

69.7

2390

116.2

3983

139.4

4780

162.6

5576

185.9

6373

209.1

7170

Plunger Diameter (in.)

Liters Per Revolution

Maximum Pressure BAR

LPM

M3/hr

LPM

M3/hr

LPM

M3/hr

1.250

0.2410

345

36.2

2.2

60.3

3.6

72.3

1.375

0.2917

306

43.8

2.6

72.9

4.4

87.5

1.500

0.3474

257

52.1

3.1

86.8

5.2

1.625

0.4075

219

61.1

3.7

101.9

1.750

0.4726

189

70.9

4.3

1.625

0.4075

219

61.1

3.7

1.750

0.4726

189

70.9

4.3

1.875

0.5426

165

81.4

2.000

0.6175

145

92.6

2.125

0.6970

128

2.250

0.7814

2.500 2.750

W100L

Model (metric)

150 RPM

W100H

W100M

W100L

150 RPM

250 RPM

300 RPM

350 RPM*

400 RPM LPM

M3/hr

450 RPM

LPM

M3/hr

LPM

M3/hr

4.3

84.4

5.1

96.4

5.3

102.1

6.1

116.7

5.8

108.5

6.5

7.0

131.3

104.2

6.3

121.6

7.3

138.9

8.3

156.3

7.9 9.4

6.1

122.3

7.3

142.6

8.6

163.0

9.8

183.4

11.0

118.2

7.1

141.8

8.5

165.4

9.9

189.0

11.3

212.7

12.8

101.9

6.1

122.3

7.3

142.6

8.6

163.0

9.8

183.4

11.0

118.2

7.1

141.8

8.5

165.4

9.9

189.0

11.3

212.7

12.8

4.9

135.7

8.1

162.8

9.8

189.9

11.4

217.1

13.0

244.2

14.7

5.6

154.4

9.3

185.3

11.1

216.1

13.0

247.0

14.8

277.9

16.7

104.6

6.3

174.3

10.5

209.1

12.5

244.0

14.6

278.8

16.7

313.7

18.8

114

117.2

7.0

195.3

11.7

234.4

14.1

273.5

16.4

312.6

18.8

351.6

21.1

0.9649

92

144.7

8.7

241.2

14.5

289.5

17.4

337.7

20.3

386.0

23.2

434.2

26.1

1.1674

77

175.1

10.5

291.8

17.5

350.2

21.0

408.6

24.5

466.9

28.0

525.3

31.5

3.000

1.3895

64

208.4

12.5

347.4

20.8

416.8

25.0

486.3

29.2

555.8

33.3

625.3

37.5

3.250

1.6305

54

244.6

14.7

407.6

24.5

489.2

29.3

570.7

34.2

652.2

39.1

733.7

44.0

3.375

1.7584

51

263.8

15.8

439.6

26.4

527.5

31.7

615.4

36.9

703.4

42.2

791.3

47.5

*API Speed

General Notes 1. Capacities shown are based on 100 percent volumetric efficiency. Actual capacities are lower, based on discharge pressure and fluid compressibility. 2. API-674 and NACE-compliant designs are available; consult Weatherford for details and exceptions to these standards.

weatherford.com/pumps

2

3. For operation below 200 RPM, an auxiliary lubrication system is required. 4. Standard plunger sizes are shown, however other sizes are available upon request.

Š 2013-2014 Weatherford. All rights reserved.

TIS0105.01

Weatherford products and services are subject to the Company’s standard terms and conditions, available on request or at weatherford.com. For more information contact an authorized Weatherford representative. Unless noted otherwise, trademarks and service marks herein are the property of Weatherford and may be registered in the United States and/or other countries. Weatherford products named herein may be protected by one or more U.S. and/or foreign patents. Specifications are subject to change without notice. Weatherford sells its products and services in accordance with the terms and conditions set forth in the applicable contract between Weatherford and the client.


Pump and Fluid Systems

W130 Triplex Pump Pump Specifications Rated (HP, kW)

130

97

4

102

W130H

5,000

345

W130M

3,110

214

Stroke length (in., mm) Maximum discharge pressure (PSI, Bar)

W130L Rated rod load (lb, kg)

1,750

121

8,590

3,896

API-674 speed, RPM

350

Maximum speed, RPM

450

Minimum speed, RPM

150

Crankshaft dimensions (in., mm) Diameter

3.75

95

Length (both sides)

8.31

211

.875 × .438

22 × 11

Pump

5.5

20.8

Reducer

3.0

11.4

Keyway, width × depth (in., mm) Oil capacity (gal, l)

Pump W130H

3,260

1,479

W130M

3,160

1,433

W130L

3,210

1,456

Reducer

• Cast aluminum-bronze, forged duplex stainless steel, or forged carbon steel fluid ends • Aluminum-bronze or duplex stainless steel stuffing boxes • Various valve designs offered per fluid end style • Tungsten carbide coated plungers over stainless steel base or solid ceramic plungers

Weight (lb, kg); estimates only

500

Mechanical efficiency

Standard Equipment

227 90%

Flange Connections

• Double extended crankshaft • Multiple plunger packing arrangements offered

Optional Accessories • Weatherford bolt on gear reducers (ratios)

–– 2.61:1 –– 3.15:1

Pump Model

Discharge Connection Sizes (in., mm)

Suction Connection Sizes (in., mm)

W130H

1.5 (38.1) ANSI 2500 RJ

3 (76.2) ANSI 300 FF

W130M

1.5 (38.1) API 5000 RJ

3 (76.2) ANSI 150 FF

W130L

2.5 (63.5) API 2000 RJ

5 (127) ANSI 150 FF

–– 3.42:1 –– 3.89:1

–– 4.27:1 –– 5.23:1

• Packing lubricators • Customized plunger packing arrangements • Complete pump packages

Technical Support pumps@weatherford.com 1-281-252-7867

weatherford.com/pumps

1

© 2012014 Weatherford. All rights reserved.

TIS0104.01


Pump and Fluid Systems

W130 Triplex Pump Performance Ratings Model (standard)

Plunger Diameter (in.)

Gallons Per Revolution

Rated Pressure PSI

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

1.375

0.0771

5,000

11.6

397

19.3

661

23.1

793

27.0

926

30.9

1,058

34.7

1,190

W130H

W130M

W130L

Model (metric)

150 RPM

250 RPM

300 RPM

350 RPM*

400 RPM

450 RPM

1.500

0.0918

4,860

13.8

472

22.9

787

27.5

944

32.1

1,102

36.7

1,295

41.3

1,416

1.625

0.1077

4,140

16.2

554

26.9

923

32.3

1,108

37.7

1,293

43.1

1,479

48.5

1,662

1.750

0.1249

3,570

18.7

643

31.2

1,071

37.5

1,285

43.7

1,499

50.0

1,714

56.2

1,928

1.875

0.1434

3,110

21.5

738

35.9

1,229

43.0

1,475

50.2

1,721

57.4

1,967

64.5

2,213

2.000

0.1632

2,730

24.5

839

40.8

1,399

49.0

1,679

57.1

1,958

65.3

2,238

73.4

2,518

2.125

0.1842

2,420

27.6

948

46.1

1,579

55.3

1,895

64.5

2,211

73.7

2,527

82.9

2,843

2.250

0.2065

2,160

31.0

1,062

51.6

1,770

62.0

2,125

72.3

2,479

82.6

2,833

92.9

3,187

2.375

0.2301

1,940

34.5

1,184

57.5

1,973

69.0

2,367

80.5

2,762

92.1

3,156

103.6

3,551

2.500

0.2550

1,750

38.2

1,311

63.7

2,186

76.5

2,623

89.2

3,060

102.0

3,497

114.7

3,934

2.625

0.2811

1,590

42.2

1,446

70.3

2,410

84.3

2,892

98.4

3,374

112.5

3,856

126.5

4,338

2.750

0.3085

1,450

46.3

1,587

77.1

2,645

92.6

3,174

108.0

3,703

123.4

4,232

138.8

4,760

3.000

0.3672

1,220

55.1

1,888

91.8

3,147

110.2

3,777

128.5

4,406

146.9

5,036

165.2

5,665

3.250

0.4309

1,040

64.6

2,216

107.7

3,694

129.3

4,433

150.8

5,171

172.4

5,910

193.9

6,649

3.500

0.4998

890

75.0

2,570

124.9

4,284

149.9

5,141

174.9

5,998

199.9

6,854

224.9

7,711

3.625

0.5361

830

80.4

2,757

134.0

4,595

160.8

5,515

187.6

6,434

214.5

7,353

241.3

8,272

Plunger Diameter (in.)

Liters Per Revolution

Maximum Pressure BAR

LPM

M3/hr

LPM

M3/hr

1.375

0.2920

345

43.8

2.6

73.0

1.500

0.3475

335

52.1

3.1

86.9

1.625

0.4078

285

61.2

3.7

1.750

0.4729

246

70.9

1.875

0.5429

214

81.4

2.000

0.6177

188

2.125

0.6973

2.250

W130H

W130M

W130L

150 RPM

250 RPM

300 RPM

350 RPM*

LPM

M3/hr

LPM

M3/hr

4.4

87.6

5.3

102.2

5.2

104.2

6.3

121.6

101.9

6.1

122.3

7.3

142.7

4.3

118.2

7.1

141.9

8.5

4.9

135.7

8.1

162.9

9.8

92.7

5.6

154.4

9.3

185.3

167

104.6

6.3

174.3

10.5

0.7818

149

117.3

7.0

195.4

400 RPM

450 RPM

LPM

M3/hr

LPM

M3/hr

6.1

116.8

7.0

131.4

7.9

7.3

139.0

8.3

156.4

9.4

8.6

163.1

9.8

186.5

11.0

165.5

9.9

189.2

11.4

212.8

12.8

190.0

11.4

217.2

13.0

244.3

14.7

11.1

216.2

13.0

247.1

14.8

278.0

16.7

209.2

12.6

244.1

14.6

278.9

16.7

313.8

18.8

11.7

234.5

14.1

273.6

16.4

312.7

18.8

351.8

21.1

2.375

0.8711

134

130.7

7.8

217.8

13.1

261.3

15.7

304.9

18.3

348.4

20.9

392.0

23.5

2.500

0.9652

121

144.8

8.7

241.3

14.5

289.6

17.4

337.8

20.3

386.1

23.2

434.3

26.1

2.625

1.0641

109

159.6

9.6

266.0

16.0

319.2

19.2

372.4

22.3

425.6

25.5

478.8

28.7

2.750

1.1679

100

175.2

10.5

292.0

17.5

350.4

21.0

408.8

24.5

467.1

28.0

252.5

31.5

3.000

1.3898

84

208.5

12.5

347.5

20.8

417.0

25.0

486.4

29.2

555.9

33.4

625.4

37.5

3.250

1.6311

71

244.7

14.7

407.8

24.5

489.3

29.4

570.9

34.3

652.5

39.1

734.0

44.0

3.500

1.8917

62

283.8

17.0

472.9

28.4

567.5

34.1

662.1

39.7

756.7

45.4

851.3

51.1

3.625

2.0293

57

304.4

18.3

507.3

30.4

608.8

36.5

710.2

42.6

811.7

48.7

913.2

54.8

*API Speed

General Notes 1. Capacities shown are based on 100 percent volumetric efficiency. Actual capacities are lower, based on discharge pressure and fluid compressibility. 2. API-674 and NACE-compliant designs are available; consult Weatherford for details and exceptions to these standards.

weatherford.com/pumps

2

3. For operation below 200 RPM, an auxiliary lubrication system is required. 4. Standard plunger sizes are shown, however other sizes are available upon request.

Š 2012014 Weatherford. All rights reserved.

TIS0104.01

Weatherford products and services are subject to the Company’s standard terms and conditions, available on request or at weatherford.com. For more information contact an authorized Weatherford representative. Unless noted otherwise, trademarks and service marks herein are the property of Weatherford and may be registered in the United States and/or other countries. Weatherford products named herein may be protected by one or more U.S. and/or foreign patents. Specifications are subject to change without notice. Weatherford sells its products and services in accordance with the terms and conditions set forth in the applicable contract between Weatherford and the client.


Pump and Fluid Systems

W165 Triplex Pump Pump Specifications Rated (HP, kW)

165

123

5

127

W165H

5,000

345

W165M

3,120

215

W165L

1,650

114

Stroke length (in., mm) Maximum discharge pressure (PSI, Bar)

Rated rod load (lb, kg)

9,800

4,445

API-674 speed, RPM

310

Maximum speed, RPM

400

Minimum speed, RPM

100

Standard Equipment

Crankshaft dimensions (in., mm) Diameter

4.125

105

Length (long)

7.92

201

Length (short)

5.62

149

1.00 × .50

25 × 13

8.0

30.3

2.25 to 3.5

8.52 to 13.25

Keyway, width × depth (in., mm) Oil capacity (gal, l) Pump Reducer (varies with ratio)

• Cast aluminum-bronze, forged duplex stainless steel, or forged carbon steel fluid ends • Aluminum-bronze or duplex stainless steel stuffing boxes • Various valve designs offered per fluid end style • Tungsten carbide coated plungers over stainless steel base or solid ceramic plungers • Double extended crankshaft

Weight (lb, kg); estimates only

Pump

• Multiple plunger packing arrangements offered

W165H

4,213

1,911

W165M

4,132

1,874

W165L

4,037

1,831

Reducer

800

Mechanical efficiency

Optional Accessories

363 90%

• Weatherford bolt on gear reducers (ratios)

–– 2.80:1 –– 3.22:1 –– 3.46:1

Flange Connections

–– 4.00:1 –– 4.38:1 –– 4.78:1

–– 4.96:1 –– 5.74:1

• Packing lubricators Pump Model

Discharge Connection Sizes (in., mm)

Suction Connection Sizes (in., mm)

• Customized plunger packing arrangements • Complete pump packages

W165H

2 (50.8) ANSI 2500 RJ

3 (76.2) API 2000 RJ

W165M

2 (50.8) API 5000 RJ

4 (101.6) ANSI 150 FF

W165L

3 (76.2) API 2000 RJ

6 (152.4) ANSI 150 FF

Technical Support pumps@weatherford.com 1-281-252-7867

weatherford.com/pumps

1

© 2013-2014 Weatherford. All rights reserved.

TIS0102.01


Pump and Fluid Systems

W165 Triplex Pump Performance Ratings

Plunger Maximum Model Gallons Per Diameter Pressure (standard) Revolution (in.) PSI 1.500 0.1147 5000 1.625 0.1347 4730 W165H 1.750 0.1562 4070 1.875 0.1793 3550 2.000 0.2040 3120 2.000 0.2040 3120 2.125 0.2303 2760 2.250 0.2582 2460 W165M 2.375 0.2877 2210 2.500 0.3187 2000 2.625 0.3514 1810 2.750 0.3857 1650 2.750 0.3857 1650 3.000 0.4590 1390 3.250 0.5387 1180 W165L 3.500 0.6247 1020 3.750 0.7172 890 4.000 0.8160 780 Model (metric)

W165H

W165M

W165L

100 RPM

150 RPM

200 RPM

310 RPM*

350 RPM

400 RPM

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

11.5 13.5 15.6 17.9 20.4 20.4 23.0 25.8 28.8 31.9 35.1 38.6 38.6 45.9 53.9 62.5 71.7 81.6

393 462 535 615 600 699 790 885 986 1093 1205 1322 1322 1574 1847 2142 2459 2798

17.2 20.2 23.4 26.9 30.6 30.6 34.5 38.7 43.2 47.8 52.7 57.9 57.9 68.8 80.8 93.7 107.6 122.4

590 693 803 922 1049 1049 1184 1328 1479 1639 1807 1984 1984 2361 2770 3213 3688 4197

22.9 26.9 31.2 35.9 40.8 40.8 46.1 51.6 57.5 63.7 70.3 77.1 77.1 91.8 107.7 124.9 143.4 163.2

787 923 1071 1229 1399 1399 1579 1770 1973 2186 2410 2645 2645 3147 3694 4284 4918 5595

35.6 41.7 48.4 55.6 63.2 63.2 71.4 80.0 89.2 98.8 108.9 119.6 119.6 142.3 167.0 193.7 222.3 253.0

1220 1431 1660 1906 2168 2168 2448 2744 3058 3388 3735 4099 4099 4879 5725 6640 7623 8673

40.2 47.1 54.7 62.8 71.4 71.4 80.6 90.4 100.7 111.6 123.0 135.0 135.0 160.6 188.5 218.7 251.0 285.6

1377 1616 1674 2152 2448 2448 2764 3098 3452 3825 4217 4628 4628 5508 6464 7497 8606 9792

45.9 53.9 62.5 71.7 81.6 81.6 92.1 103.3 115.1 127.5 140.6 154.3 154.3 183.6 215.5 249.9 286.9 326.4

1574 1847 2142 2459 2798 2798 3158 3541 3945 4371 4819 5289 5289 6295 7388 8568 9836 11191

Plunger Maximum 100 RPM Liters Per Diameter Pressure Revolution LPM M3/hr (in.) BAR 1.500 0.4343 345 43.4 2.6 1.625 0.5097 326 51.0 3.1 1.750 0.5912 281 59.1 3.5 1.875 0.6786 245 67.9 4.1 2.000 0.7721 215 77.2 4.6 2.000 0.7721 215 77.2 4.6 2.125 0.8717 190 87.2 5.2 2.250 0.9772 170 97.7 5.9 2.375 1.0888 152 108.9 6.5 2.500 1.2065 138 120.6 7.2 2.625 1.3301 125 133.0 8.0 2.750 1.4598 114 146.0 8.8 2.750 1.4598 114 146.0 8.8 3.000 1.7373 96 173.7 10.4 3.250 2.0389 81 203.9 12.2 3.500 2.3647 70 236.5 14.2 3.750 2.7145 61 271.5 16.3 4.000 3.0886 54 308.9 18.5

150 RPM LPM

3

M /hr

65.1 76.5 88.7 101.8 115.8 115.8 130.8 146.6 163.3 181.0 199.5 219.0 219.0 260.6 305.8 354.7 407.2 463.3

3.9 4.6 5.3 6.1 6.9 6.9 7.8 8.8 9.8 10.9 12.0 13.1 13.1 15.6 18.4 21.3 24.4 27.8

200 RPM LPM

3

M /hr

86.9 101.9 118.2 135.7 154.4 154.4 174.3 195.4 217.8 241.3 266.0 292.0 292.0 347.5 407.8 472.9 542.9 617.7

5.2 6.1 7.1 8.1 9.3 9.3 10.5 11.7 13.1 14.5 16.0 17.5 17.5 20.8 24.5 28.4 32.6 37.1

310 RPM* LPM

3

M /hr

134.6 158.0 183.3 210.4 239.4 239.4 270.2 302.9 337.5 374.0 412.3 452.5 452.5 538.6 632.1 733.0 841.5 957.5

8.1 9.5 11.0 12.6 14.4 14.4 16.2 18.2 20.3 22.4 24.7 27.2 27.2 32.3 37.9 44.0 50.5 57.4

350 RPM

400 RPM

LPM

3

M /hr

LPM

M3/hr

152.0 178.4 206.9 237.5 270.2 270.2 305.1 342.0 381.1 422.3 465.5 510.9 510.9 608.1 713.6 827.6 950.1 1081.0

9.1 10.7 12.4 14.3 16.2 16.2 18.3 20.5 22.9 25.3 27.9 30.7 30.7 36.5 42.8 49.7 57.0 64.9

173.7 203.9 236.5 271.5 308.9 308.9 348.7 390.9 435.5 482.6 532.1 583.9 583.9 694.9 815.6 945.9 1085.8 1235.4

10.4 12.2 14.2 16.3 18.5 18.5 20.9 23.5 26.1 29.0 31.9 35.0 35.0 41.7 48.9 56.8 65.1 74.1

*API Speed

General Notes 1. Capacities shown are based on 100 percent volumetric efficiency. Actual capacities are lower, based on discharge pressure and fluid compressibility. 2. API-674 and NACE-compliant designs are available; consult Weatherford for details and exceptions to these standards.

weatherford.com/pumps

2

3. For operation below 200 RPM, an auxiliary lubrication system is required. 4. Standard plunger sizes are shown, however other sizes are available upon request. 5. Spherical valves must be installed when using 4.00 in. plungers.

Š 2013-2014 Weatherford. All rights reserved.

TIS0102.01

Weatherford products and services are subject to the Company’s standard terms and conditions, available on request or at weatherford.com. For more information contact an authorized Weatherford representative. Unless noted otherwise, trademarks and service marks herein are the property of Weatherford and may be registered in the United States and/or other countries. Weatherford products named herein may be protected by one or more U.S. and/or foreign patents. For more information, contact patents@weatherford.com. Specifications are subject to change without notice. Weatherford sells its products and services in accordance with the terms and conditions set forth in the applicable contract between Weatherford and the client.


Pump and Fluid Systems

W200 Triplex Pump Pump Specifications Rated (HP, kW)

200

149

5

127

W200H

5,000

345

W200M

3,350

231

Stroke length (in., mm) Maximum discharge pressure (PSI, Bar)

W200L Rated rod load (lb, kg)

1,680

116

11,870

5,385

API-674 speed, RPM

310

Maximum speed, RPM

400

Minimum speed, RPM

100

Gear reducer and packing lubricator optional.

Crankshaft dimensions (in., mm) Diameter

4.875

124

Length (long)

11.75

298

Length (short) Keyway, width × depth (in., mm)

5.62

143

1.25 × .62

32 × 16

6.5

24.6

3.5 to 6.5

13 to 25

Oil capacity (gal, l) Pump Reducer (varies with ratio) Weight (lb, kg); estimates only

W200H

4,707

2,135

W200M

4,792

2,174

W200L

4,842

2,196

Reducer

1,100

499 90%

Flange Connections Pump Model

Discharge Connection Sizes (in., mm)

• Cast aluminum-bronze, forged duplex stainless steel, or forged carbon steel fluid ends • Aluminum-bronze or duplex stainless steel stuffing boxes • Various valve designs offered per fluid end style • Tungsten carbide coated plungers over stainless steel base or solid ceramic plungers

Pump

Mechanical efficiency

Standard Equipment

• Double extended crankshaft • Multiple plunger packing arrangements offered

Optional Accessories • Weatherford bolt on gear reducers (ratios)

Suction Connection Sizes (in., mm)

W200H

2 (50.8) ANSI 2500 RJ

3 (76.2) API 2000 RJ

W200M

2 (50.8) API 5000 RJ

4 (101.6) ANSI 150 FF

W200L

3 (76.2) API 2000 RJ

6 (152.4) ANSI 150 FF

Technical Support

–– 2.27:1 –– 2.89:1 –– 3.25:1

–– 3.36:1 –– 3.69:1 –– 4.38:1

–– 4.84:1 –– 5.56:1

• Packing lubricators • Customized plunger packing arrangements • Power end lube system • Complete pump packages

pumps@weatherford.com 1-281-252-7867 weatherford.com/pumps

1

© 2013-2014 Weatherford. All rights reserved.

TIS0101.02


Pump and Fluid Systems

W200 Triplex Pump Performance Ratings Model (standard)

Plunger Diameter (in.)

W200H

W200M

W200L

Model (metric)

Gallons Per Revolution

Maximum Pressure PSI

100 RPM GPM

BPD

150 RPM GPM

BPD

200 RPM GPM

310 RPM*

BPD

GPM

BPD

350 RPM GPM

BPD

400 RPM GPM

BPD

1.250

0.0797

5000

8.0

273

12.0

410

15.9

546

24.7

847

27.9

956

31.9

1093

1.375

0.0964

5000

9.6

331

14.5

496

19.3

661

29.9

1025

33.7

1157

38.6

1322

1.500

0.1147

5000

11.5

393

17.2

590

22.9

787

35.6

1220

40.2

1377

45.9

1574

1.625

0.1347

5000

13.5

462

20.2

693

26.9

923

41.7

1431

47.1

1616

53.9

1847

1.750

0.1562

4930

15.6

535

23.4

803

31.2

1071

48.4

1660

54.7

1874

62.5

2142

1.875

0.1793

4300

17.9

615

26.9

922

35.9

1229

55.6

1906

62.8

2152

71.7

2459

2.000

0.2040

3780

20.4

699

30.6

1049

40.8

1399

63.2

2168

71.4

2448

81.6

2798

2.000

0.2040

3350

20.4

699

30.6

1049

40.8

1399

63.2

2168

71.4

2448

81.6

2798

2.125

0.2303

3350

23.0

790

34.5

1184

46.1

1579

71.4

2448

80.6

2764

92.1

3158

2.250

0.2582

2990

25.8

885

38.7

1328

51.6

1770

80.0

2744

90.4

3098

103.3

3541

2.375

0.2877

2680

28.8

986

43.2

1479

57.5

1973

89.2

3058

100.7

3452

115.1

3945

2.500

0.3187

2420

31.9

1093

47.8

1639

63.7

2186

98.8

3388

111.6

3825

127.5

4371

2.625

0.3514

2190

35.1

1205

52.7

1807

70.3

2410

108.9

3735

123.0

4217

140.6

4819

2.750

0.3857

2000

38.6

1322

57.9

1984

77.1

2645

119.6

4099

135.0

4628

154.3

5289

2.750

0.3857

1680

38.6

1322

57.9

1984

77.1

2645

119.6

4099

135.0

4628

154.3

5289

3.000

0.4590

1680

45.9

1574

68.8

2361

91.8

3147

142.3

4879

160.6

5508

183.6

6295

3.250

0.5387

1430

53.9

1847

80.8

2770

107.7

3694

167.0

5725

188.5

6464

215.5

7388

3.500

0.6247

1230

62.5

2142

93.7

3213

124.9

4284

193.7

6640

218.7

7497

249.9

8568

3.750

0.7172

1070

71.7

2459

107.6

3688

143.4

4918

222.3

7623

251.0

8606

286.9

9836

4.000

0.8160

940

81.6

2798

122.4

4197

163.2

5595

253.0

8673

285.6

9792

326.4

11191

Plunger Diameter (in.)

Liters Per Revolution

Maximum Pressure BAR

LPM

M3/hr

LPM

M3/hr

LPM

M3/hr

LPM

M3/hr

LPM

M3/hr

LPM

1.250

0.3016

345

30.2

1.8

45.2

2.7

60.3

3.6

93.5

5.6

105.6

6.3

120.6

7.2

1.375

0.3650

345

36.5

2.2

54.7

3.3

73.0

4.4

113.1

6.8

127.7

7.7

146.0

8.8

W200H

W200M

W200L

100 RPM

150 RPM

200 RPM

310 RPM*

350 RPM

400 RPM M3/hr

1.500

0.4343

345

43.4

2.6

65.1

3.9

86.9

5.2

134.6

8.1

152.0

9.1

173.7

10.4

1.625

0.5097

345

51.0

3.1

76.5

4.6

101.9

6.1

158.0

9.5

178.4

10.7

203.9

12.2

1.750

0.5912

340

59.1

3.5

88.7

5.3

118.2

7.1

183.3

11.0

206.9

12.4

236.5

14.2

1.875

0.6786

296

67.9

4.1

101.8

6.1

135.7

8.1

210.4

12.6

237.5

14.3

271.5

16.3

2.000

0.7721

260

77.2

4.6

115.8

6.9

154.4

9.3

239.4

14.4

270.2

16.2

308.9

18.5

2.000

0.7721

231

77.2

4.6

115.8

6.9

154.4

9.3

239.4

14.4

270.2

16.2

308.9

18.5

2.125

0.8717

231

87.2

5.2

130.8

7.8

174.3

10.5

270.2

16.2

305.1

18.3

348.7

20.9

2.250

0.9772

206

97.7

5.9

146.6

8.8

195.4

11.7

302.9

18.2

342.0

20.5

390.9

23.5

2.375

1.0888

185

108.9

6.5

163.3

9.8

217.8

13.1

337.5

20.3

381.1

22.9

435.5

26.1

2.500

1.2065

167

120.6

7.2

181.0

10.9

241.3

14.5

374.0

22.4

422.3

25.3

482.6

29.0

2.625

1.3301

151

133.0

8.0

199.5

12.0

266.0

16.0

412.3

24.7

465.5

27.9

532.1

31.9

2.750

1.4598

138

146.0

8.8

219.0

13.1

292.0

17.5

425.5

27.2

510.9

30.7

583.9

35.0

2.750

1.4598

116

146.0

8.8

219.0

13.1

292.0

17.5

425.5

27.2

510.9

30.7

583.9

35.0

3.000

1.7373

116

173.7

10.4

260.6

15.6

347.5

20.8

538.6

32.3

608.1

36.5

694.9

41.7

3.250

2.0389

99

203.9

12.2

305.8

18.4

407.8

24.5

632.1

37.9

713.6

42.8

815.6

48.9

3.500

2.3647

85

236.5

14.2

354.7

21.3

472.9

28.4

733.0

44.0

827.6

49.7

945.9

56.8

3.750

2.7145

74

271.5

16.3

407.2

24.4

542.9

32.6

841.5

50.5

950.1

57.0

1085.8

65.1

4.000

3.0886

65

308.9

18.5

463.3

27.8

617.7

37.1

957.5

57.4

1081.0

64.9

1235.4

74.1

*API Speed

General Notes 1. Capacities shown are based on 100 percent volumetric efficiency. Actual capacities are lower, based on discharge pressure and fluid compressibility. 2. API-674 and NACE-compliant designs are available; consult Weatherford for details and exceptions to these standards.

weatherford.com/pumps

2

3. For operation below 200 RPM, an auxiliary lubrication system is required. 4. Standard plunger sizes are shown, however other sizes are available upon request. 5. Spherical valves must be installed when using 4.00 in. plungers.

Š 2013-2014 Weatherford. All rights reserved.

TIS0101.02

Weatherford products and services are subject to the Company’s standard terms and conditions, available on request or at weatherford.com. For more information contact an authorized Weatherford representative. Unless noted otherwise, trademarks and service marks herein are the property of Weatherford and may be registered in the United States and/or other countries. Weatherford products named herein may be protected by one or more U.S. and/or foreign patents. For more information, contact patents@weatherford.com. Specifications are subject to change without notice. Weatherford sells its products and services in accordance with the terms and conditions set forth in the applicable contract between Weatherford and the client.


Pump and Fluid Systems

W250 Triplex Pump Pump Specifications Rated (HP, kW)

250

187

5

127

W250H

5,000

345

W250M

3,030

209

Stroke length (in., mm) Maximum discharge pressure (PSI, Bar)

W250L Rated rod load (lb, kg)

1,540

106

14,885

6,738

API-674 speed, RPM

310

Maximum speed, RPM

400

Minimum speed, RPM

100

Standard Equipment

Diameter

4.875

124

• Cast aluminum-bronze, forged duplex stainless steel, or forged carbon steel fluid ends

Length (long)

11.85

301

• Aluminum-bronze or duplex stainless steel stuffing boxes

Length (short)

5.62

143

1.25 × .62

32 × 16

• Various valve designs offered per fluid end style

Crankshaft dimensions (in., mm)

Keyway, width × depth (in., mm) Oil capacity (gal, l) Pump Reducer (varies with ratio)

6.5

24.6

3.5 to 6.5

13 to 25

Pump W250H

4,932

2,237

W250M

4,958

2,249

W250L

4,588

2,081

1,100

499

Mechanical efficiency

90%

Flange Connections Pump Model

Discharge Connection Sizes (in., mm)

• Double extended crankshaft • Multiple plunger packing arrangements offered

Weight (lb, kg); estimates only

Reducer

• Tungsten carbide coated plungers over stainless steel base or solid ceramic plungers

Optional Accessories • Weatherford bolt on gear reducers (ratios)

–– 2.27:1 –– 2.89:1 –– 3.25:1

–– 3.36:1 –– 3.69:1 –– 4.38:1

–– 4.84:1 –– 5.56:1

• Packing lubricators Suction Connection Sizes (in., mm)

W250H

2 (50.8) ANSI 2500 RJ

3 (76.2) API 2000 RJ

W250M

2 (50.8) API 5000 RJ

4 (101.6) ANSI 150 FF

W250L

3 (76.2) API 2000 RJ

6 (152.4) ANSI 150 FF

• Customized plunger packing arrangements • Complete pump packages

Technical Support pumps@weatherford.com 1-281-252-7867

weatherford.com/pumps

1

© 2013-2014 Weatherford. All rights reserved.

TIS0103.01


Pump and Fluid Systems

W250 Triplex Pump Performance Ratings Model (standard)

W250H

W250M

W250L

Model (metric)

W250H

W250M

W250L

Plunger Diameter (in.) 1.875 2.000 2.125 2.250 2.500 2.750 3.000 3.250 3.500 3.750 4.000 4.250 4.500 Plunger Diameter (in.) 1.875 2.000 2.125 2.250 2.500 2.750 3.000 3.250 3.500 3.750 4.000 4.250 4.500

Gallons Per Revolution 0.1793 0.2040 0.2303 0.2582 0.3187 0.3857 0.4590 0.5387 0.6247 0.7172 0.8160 0.9212 1.0327 Liters Per Revolution 0.6786 0.7721 0.8717 0.9772 1.2065 1.4598 1.7373 2.0389 2.3647 2.7145 3.0886 3.4867 3.9089

Maximum Pressure PSI 5000 4730 4190 3740 3030 2500 2100 1790 1540 1340 1180 1050 930 Maximum Pressure BAR 371 326 289 257 209 172 145 123 106 93 81 72 64

100 RPM

150 RPM

200 RPM

310 RPM*

BPD

GPM

BPD

GPM

BPD

GPM

17.9 20.4 23.0 25.8 31.9 38.6 45.9 53.9 62.5 71.7 81.6 92.1 103.3

615 699 790 885 1093 1322 1574 1847 2142 2459 2798 3158 3541

26.9 30.6 34.5 38.7 47.8 57.9 68.8 80.8 93.7 107.6 122.4 138.2 154.9

922 1049 1184 1328 1639 1984 2361 2770 3213 3688 4197 4738 5311

35.9 40.8 46.1 51.6 63.7 77.1 91.8 107.7 124.9 143.4 163.2 184.2 206.5

1229 1399 1579 1770 2186 2645 3147 3694 4284 4918 5595 6317 7082

55.6 1906 63.2 2168 71.4 2448 80.0 2744 98.8 3388 119.6 4099 142.3 4879 167.0 5725 193.7 6640 222.3 7623 253.0 8673 285.6 9791 320.2 10977

62.8 2152 71.4 2448 80.6 2764 90.4 3098 111.6 3825 135.0 4628 160.6 5508 188.5 6464 218.7 7497 251.0 8606 285.6 9792 322.4 11054 361.5 12393

71.7 2459 81.6 2798 92.1 3158 103.3 3541 127.5 4371 154.3 5289 183.6 6295 215.5 7388 249.9 8568 286.9 9836 326.4 11191 368.5 12633 413.1 14163

310 RPM*

350 RPM

400 RPM

150 RPM

200 RPM

GPM

BPD

400 RPM

GPM

100 RPM

BPD

350 RPM

GPM

BPD

LPM

M /hr

LPM

M /hr

LPM

M /hr

LPM

M /hr

LPM

M /hr

LPM

M3/hr

67.9 77.2 87.2 97.7 120.6 146.0 173.7 203.9 236.5 271.5 308.9 348.7 390.9

4.1 4.6 5.2 5.9 7.2 8.8 10.4 12.2 14.2 16.3 18.5 20.9 23.5

101.8 115.8 130.8 146.6 181.0 219.0 260.6 305.8 354.7 407.2 463.3 523.0 586.3

6.1 6.9 7.8 8.8 10.9 13.1 15.6 18.4 21.3 24.4 27.8 31.4 35.2

135.7 154.4 174.3 195.4 241.3 292.0 347.5 407.8 472.9 542.9 617.7 697.3 781.8

8.1 9.3 10.5 11.7 14.5 17.5 20.8 24.5 28.4 32.6 37.1 41.8 46.9

210.4 239.4 270.2 302.9 374.0 452.5 538.6 632.1 733.0 841.5 957.5 1080.9 1211.8

12.6 14.4 16.2 18.2 22.4 27.2 32.3 37.9 44.0 50.5 57.4 64.9 72.7

237.5 270.2 305.1 342.0 422.3 510.9 608.1 713.6 827.6 950.1 1081.0 1220.3 1368.1

14.3 16.2 18.3 20.5 25.3 30.7 36.5 42.8 49.7 57.0 64.9 73.2 82.1

271.5 308.9 348.7 390.9 482.6 583.9 694.9 815.6 945.9 1,85.8 1235.4 1394.7 1563.6

16.3 18.5 20.9 23.5 29.0 35.0 41.7 48.9 56.8 65.1 74.1 83.7 93.8

3

3

3

3

3

*API Speed

General Notes 1. Capacities shown are based on 100 percent volumetric efficiency. Actual capacities are lower, based on discharge pressure and fluid compressibility. 2. API-674 and NACE-compliant designs are available; consult Weatherford for details and exceptions to these standards.

weatherford.com/pumps

2

3. For operation below 200 RPM, an auxiliary lubrication system is required. 4. Standard plunger sizes are shown, however other sizes are available upon request. 5. Spherical valves must be installed when using 4.00 in. plungers.

Š 2013-2014 Weatherford. All rights reserved.

TIS0103.01

Weatherford products and services are subject to the Company’s standard terms and conditions, available on request or at weatherford.com. For more information contact an authorized Weatherford representative. Unless noted otherwise, trademarks and service marks herein are the property of Weatherford and may be registered in the United States and/or other countries. Weatherford products named herein may be protected by one or more U.S. and/or foreign patents. For more information, contact patents@weatherford.com. Specifications are subject to change without notice. Weatherford sells its products and services in accordance with the terms and conditions set forth in the applicable contract between Weatherford and the client.


Pump and Fluid Systems

W300 Quintuplex Pump Pump Specifications Rated (HP, kW)

300

224

5

127

W300H

5,000

345

W300M

3,000

207

Stroke length (in., mm) Maximum discharge pressure (PSI, Bar)

W300L Rated rod load (lb, kg)

1,650

114

10,700

4,853

API-674 speed, RPM

310

Maximum speed, RPM

400

Minimum speed, RPM

100

Standard Equipment

Diameter

4.875

124

• Cast aluminum-bronze, forged duplex stainless steel, or forged carbon steel fluid ends

Length (long)

11.62

295

• Aluminum-bronze or duplex stainless steel stuffing boxes

Length (short)

5.62

143

1.25 × .62

32 × 16

• Various valve designs offered per fluid end style

Crankshaft dimensions (in., mm)

Keyway, width × depth (in., mm) Oil capacity (gal, l) Pump Reducer (varies with ratio)

12

46

3.5 to 6.5

13 to 25

• Tungsten carbide coated plungers over stainless steel base or solid ceramic plungers • Double extended crankshaft • Multiple plunger packing arrangements offered

Weight (lb, kg); estimates only

Pump W300H

6,840

3,103

W300M

6,750

3,062

W300L

7,000

3,175

1,100

499

Reducer Mechanical efficiency

90%

Flange Connections Pump Model

Optional Accessories • Weatherford bolt on gear reducers (ratios)

–– 2.27:1 –– 2.89:1 –– 3.25:1

–– 3.36:1 –– 3.69:1 –– 4.38:1

–– 4.84:1 –– 5.56:1

• Packing lubricators

Discharge Connection Sizes (in., mm)

Suction Connection Sizes (in., mm)

W300H

2 (50.8) ANSI 2500 RJ

6 (152.4) NSD 600 RJ*

W300M

3 (76.2) NSD 5000 RJ*

6 (152.4) NSD 600 RJ*

W300L

4 (101.6) API 2000 RJ

8 (203.2) ANSI 150 FF

*One blind and one weld neck flange provided

• Customized plunger packing arrangements • Power end lube system • Complete pump packages

Technical Support pumps@weatherford.com 1-281-252-7867

weatherford.com/pumps

1

© 2012-2014 Weatherford. All rights reserved.

TIS0100.01


Pump and Fluid Systems

W300 Quintuplex Pump Performance Ratings Model (standard)

Plunger Diameter (in.)

Gallons Per Revolution

Maximum Pressure PSI

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

GPM

BPD

1.500

0.1912

5000

19.1

656

28.7

984

38.2

1311

59.3

2033

66.9

2295

76.5

2623

W300H

W300M

W300L

Model (metric)

100 RPM

150 RPM

200 RPM

310 RPM*

350 RPM

400 RPM

1.625

0.2245

5000

22.4

770

33.7

1154

44.9

1539

69.6

2386

78.6

2693

89.8

3078

1.750

0.2603

4450

26.0

892

39.0

1339

52.1

1785

80.7

2767

91.1

3124

104.1

3570

1.875

0.2988

3880

29.9

1025

44.8

1537

59.8

2049

92.6

3176

104.6

3586

119.5

4098

2.000

0.3400

3410

34.0

1166

51.0

1749

68.0

2331

105.4

3614

119.0

4080

136.0

4663

2.000

0.3400

3000

34.0

1166

51.0

1749

68.0

2331

105.4

36.14

119.0

4080

136.0

4663

2.125

0.3838

3000

38.4

1316

57.6

1974

76.8

2632

119.0

4080

134.3

4606

153.5

5264

2.250

0.4303

2690

43.0

1475

64.5

2213

86.1

2951

133.4

4574

150.6

5164

172.1

5901

2.375

0.4795

2420

47.9

1644

71.9

2466

95.9

3288

148.6

5096

167.8

5753

191.8

6575

2.500

0.5312

2180

53.1

1821

79.7

2732

106.2

3643

164.7

5646

185.9

6375

212.5

7286

2.750

0.6428

1800

64.3

2204

96.4

3306

128.6

4408

199.3

6832

225.0

7714

257.1

8816

2.750

0.6428

1650

64.3

2204

96.4

3306

128.6

4408

199.3

6832

225.0

7714

257.1

8816

3.000

0.7650

1510

76.5

2623

114.7

3934

153.0

5246

237.1

8131

267.7

9180

306.0

10491

3.250

0.8978

1290

89.8

3078

134.7

4617

179.6

6156

278.3

9542

314.2

10774

359.1

12313

3.500

1.0412

1110

104.1

3570

156.2

5355

208.2

7140

322.8

11067

364.4

12495

416.5

14280

3.750

1.1953

970

119.5

4098

179.3

6147

239.1

8196

370.5

12704

418.4

14344

478.1

16393

4.000

1.3600

850

136.0

4663

204.0

6994

272.0

9326

421.6

14455

476.0

16320

544.0

18651

Plunger Diameter (in.)

Liters Per Revolution

Maximum Pressure BAR

W300H

W300M

W300L

100 RPM LPM

M /hr 3

150 RPM LPM

M /hr 3

200 RPM LPM

310 RPM*

M /hr 3

LPM

M /hr 3

350 RPM LPM

M /hr 3

400 RPM LPM

M3/hr

1.500

0.7239

345

72.4

4.3

108.6

6.5

144.8

8.7

224.4

13.5

253.4

15.2

289.6

17.4

1.625

0.8495

345

85.0

5.1

127.4

7.6

169.9

10.2

263.3

15.8

297.3

17.8

339.8

20.4

1.750

0.9853

307

98.5

5.9

147.8

8.9

197.1

11.8

305.4

18.3

344.9

20.7

394.1

23.6

1.875

1.1310

268

113.1

6.8

169.7

10.2

226.2

13.6

350.6

21.0

395.9

23.8

452.4

27.1

2.000

1.2869

235

128.7

7.7

193.0

11.6

257.4

15.4

398.9

23.9

450.4

27.0

514.8

30.9

2.000

1.2869

207

128.7

7.7

193.0

11.6

257.4

15.4

398.9

23.9

450.4

27.0

514.8

30.9

2.125

1.4527

207

145.3

8.7

217.9

13.1

290.5

17.4

450.3

27.0

508.4

30.5

581.1

34.9

2.250

1.6287

185

162.9

9.8

244.3

14.7

325.7

19.5

504.9

30.3

570.0

34.2

651.5

39.1

2.375

1.8147

167

181.5

10.9

272.2

16.3

362.9

21.8

562.6

33.8

635.1

38.1

725.9

43.6

2.500

2.0108

150

201.1

12.1

301.6

18.1

402.2

24.1

623.3

37.4

703.8

42.2

804.3

48.3

2.750

2.4330

124

243.3

14.6

365.0

21.9

486.6

29.2

754.2

45.3

851.6

51.1

973.2

58.4

2.750

2.4330

114

243.3

14.6

365.0

21.9

486.6

29.2

754.2

45.3

851.6

51.1

973.2

58.4

3.000

2.8955

104

289.6

17.4

434.3

26.1

579.1

34.7

897.6

53.9

1013.4

60.8

1153.2

69.5

3.250

3.3982

89

339.8

20.4

509.7

30.6

679.6

40.8

1053.4

63.2

1189.4

71.4

1359.3

81.6

3.500

3.9411

77

394.1

23.6

591.2

35.5

788.2

47.3

1221.7

73.3

1379.4

82.8

1576.4

94.6

3.750

4.5243

67

452.4

27.1

678.6

40.7

904.9

54.3

1402.5

84.2

1583.5

95.0

1809.7

108.6

4.000

5.1476

59

514.8

30.9

772.1

46.3

1029.5

61.8

1595.8

95.7

1801.7

108.1

2059.0

123.5

*API Speed

General Notes 1. Capacities shown are based on 100 percent volumetric efficiency. Actual capacities are lower, based on discharge pressure and fluid compressibility. 2. API-674 and NACE-compliant designs are available; consult Weatherford for details and exceptions to these standards.

weatherford.com/pumps

2

3. For operation below 200 RPM, an auxiliary lubrication system is required. 4. Standard plunger sizes are shown, however other sizes are available upon request. 5. Spherical valves must be installed when using 4.00 in. plungers.

Š 2012-2014 Weatherford. All rights reserved.

TIS0100.01

Weatherford products and services are subject to the Company’s standard terms and conditions, available on request or at weatherford.com. For more information contact an authorized Weatherford representative. Unless noted otherwise, trademarks and service marks herein are the property of Weatherford and may be registered in the United States and/or other countries. Weatherford products named herein may be protected by one or more U.S. and/or foreign patents. For more information, contact patents@weatherford.com. Specifications are subject to change without notice. Weatherford sells its products and services in accordance with the terms and conditions set forth in the applicable contract between Weatherford and the client.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.