VRV SYSTEMS
www.daikin.eu
H i g h t e c h , e n e r g y s av i n g a i r c o n d i t i o n e r s , e n s u r i n g c o m f o r t i n l i g h t c o m m e r c i a l a p p l i c at i o n s
ABOUT DAIKIN Daikin has a worldwide reputation based on over 80 years’ experience in the successful manufacture of high quality air conditioning equipment for industrial, commercial and residential use.
Daikin Europe N.V.
ENVIRONMENTAL AWARENESS Air Conditioning and the Environment Air conditioning systems provide a significant level of indoor comfort, making possible optimum working and living conditions in the most extreme climates. In recent years, motivated by a global awareness of the need to reduce the burdens on the environment, some manufacturers including Daikin have invested enormous efforts in limiting the negative effects associated with the production and the operation of air conditioners. Hence, models with energy saving features and improved ecoproduction techniques have seen the light of day, making a significant contribution to limiting the impact on the environment.
2
TABLE OF CONTENTS Introduction
2
Features
4
1. Wide Application Range 2. Environmental Awareness 3. Installation & Maintenance Friendly Design
4 10 11
OUTDOOR UNITS
13
1. VRV速III-S Technology 2. Specifications 3. Accessories
13 15 15
INDOOR UNITS
16
1. Features 2. Specifications & Accessories
16 23
VENTILATION
36
1. VAM-FA 2. VKM-GAM / VKM-GA
36 37
POWERFUL SELECTION PROGRAMMES
38
1. VRV速 XPRESS 2. VRV速 PRO
38 39
USER FRIENDLY CONTROL SYSTEMS
40
1. Individual Control Systems 2. Centralised Control Systems 3. Network Solutions 4. Accessories
40 42 43 48
3
S
9 pace saving
S
9 mall capacity
S
9 lim design
S
9 ilent operation
S
9 uper wide range of indoor units
FEATURES 1. WIDE APPLICATION RANGE ›› VRV®III-S outdoor unit range
VRV®III-S Heat pump
Maximum number of connectableindoor units
Minimum capacity index
Maximum capacity index
Capacity steps
RXYSQ4PAV1/RXYSQ4PAY1 RXYSQ5PAV1/RXYSQ5PAY1 RXYSQ6PAV1/RXYSQ6PAY1
6 8 9
50 62.5 70
130 162.5 182
31 31 31
›› Indoor unit capacity index
Model
20
25
32
40
50
63
71
80
100
125
200
250
Capacity Index
20
25
31.5
40
51
62,5
71
80
100
125
200
250
eg. Selected indoor units: FXCQ25 + FXFQ50 + FXDQ25 + FXDQ50 Connection ratio:
25 + 50 + 25 + 50 = 150
Possible outdoor unit: RXYSQ5PAV1
4
›› Flexible piping design The VRV ®III-S provides the long piping length possibility of 150m1 (175m equivalent piping length), with a total piping length of 300m. If the outdoor unit is installed above the indoor units, the height difference can be up to a maximum of 50m2. These generous allowances facilitate an extensive variety of system designs.
Notes: 1. 40 m when the outdoor unit is installed below indoor units. 2. Maximum piping length between the indoor unit and the first branch is 40 m.
›› Space Saving Design The VRVIII®-S is slimmer and more compact, resulting in significant savings in installation space.
VOLUME Approx. 50% reduction
765mm
(5HP)
900mm (4,5,6HP)
796mm
›› Wide operation range
50
Cooling 46°CDB
40
The VRVIII®-S system can be installed practically anywhere. The incorporation of a high pressure “dome” type compressor results in a remarkable outdoor operating temperature range from as low as -20°C in heating mode to as high as 46°C in cooling mode.
FOOTPRINT Approx. 40% reduction
320mm
30
Heating 15.5°CWB
20 10 0 -10
-5°CDB
-20
-20°CWB -30
Outdoor temperature operating range
5
›› Super wide range of indoor units
Whatever the air conditioning requirement, a Daikin indoor unit can provide the solution. The VRV®III-S can be combined with
13 DIFFERENT INDOOR UNIT MODELS in a total of 73 VARIATIONS.
Cassette type unit
Concealed ceiling unit
Floor standing unit
Indoor unitS Roundflow ceiling mounted cassette 600x600 4-way blow ceiling mounted cassette 2-way blow ceiling mounted cassette Ceiling mounted corner cassette Small concealed ceiling unit Slim concealed ceiling unit Concealed ceiling unit Concealed ceiling unit Wall mounted unit Ceiling suspended unit 4 way blow ceiling suspended unit Floor standing unit Concealed floor standing
6
20 FXFQ FXZQ FXCQ FXKQ FXDQ FXDQ FXSQ FXMQ FXAQ FXHQ FXUQ FXLQ FXNQ
25
32
40
50
63
71
80
100
125
Concealed floor standing unit
Ceiling suspended unit
Wall mounted unit
HRV Ventilation, DX coil & humidifier Ventilation & DX coil
50
80
100
VKM-GAM VKM-GA
7
›› Super silent operation Quietness is another important feature. To reduce noise and ensure comfortable operation, the latest technologies and features have been applied to the outdoor units.
Night quiet function (max. -9dBA)
Peak in the outdoor temperature
8 hrs (initial setting)
10 hrs (initial setting)
— Operation Sound dBA — Load %
Night Mode Step 1 max. - 3dB (4HP/11.2Kw)
Step 1: 47dB
Step 2 max. - 6dB (4HP/11.2Kw)
Step 2: 44dB
Step 3 max. - 9dB (4HP/11.2Kw)
Step 3: 41dB
— Capacity* %
Notes: ›› This function is available for on site setting. ›› The relationship between outdoor temperature (load) and time shown in the graph is merely an example.
Night mode starts Night mode ends
During the night the sound level of the outdoor unit can be reduced for a certain period: starting time and ending time can be input 2 modes*1 with low sound level at night: ›› Mode 1 Automatic mode Set on the outdoor PCB. Time of maximum temperature is memorised. The low operating mode will become active 8 hours*2 after the peak temperature in the daytime and operation will return to normal after 9 hours*3. ›› Mode 2 Customized mode Starting and ending times can be input. (External control adapter for outdoor unit, DTA104A61 or DTA104A62 and a separately ordered timer are necessary.) Notes: *1. Determine which mode to select depending on the climatic characteristics of each country. *2. Initial setting. Can be selected from 6, 8 and 10 hours. *3. Initial setting. Can be selected from 8, 9 and 10 hours.
Daikin indoor units operate at sound levels as low as 25 dBA
8
)dB(A
Perceived loudness
Sound
0 20 40 60 80 100 120
Treshold of hearing Extremely soft Very soft Moderately loud Very loud Extremely loud Threshold of feeling
Rustling leaves Quiet room Normal conversation City traffic noise Symphonic orchestra Jet taking off
Daikin indoor units
›› anti corrosion treatment Special anti corrosion treatment of the heat exchanger provides5 to 6 times greater resistance ag nst acid rain and salt corrosion. The use of rust proof steel sheet on the underside of the unit gives additional protection.
Improvement in corrosion resistance Corrosion resistance rating Non-treated 1 1
Salt corrosion Acid rain
Anti-corrosion treated 5 to 6 5 to 6
An anti-corrosion heat exchanger cutaway view
Hydrophilic film Aluminium Corrosion-resistant acrylic resin
Heat exchanger
Performed tests:
››
Degree of Corrosion
VDA Wechseltest Contents of single cycle (7 days): - 24 hours salt spray test SS DIN 50021 - 96 hours humidity cycle test KFW DIN 50017 - 48 hours room temperature & room humidity Testing period: 5 cycles
8 6 4 2 0 5
Kesternich test (SO2) - Contents of single cycle (48 hours) according to DIN50018 (0.21) - Testing period: 40 cycles
4
3
2
1
Cycle
10 9
Bare aluminium
Degree of Corrosion
››
8 7 6 5 4 3 2 1
.DAIKIN P.E
0
40
30
20
10
6
5
4
3
2
1
Cycle
9
2. Environmental Awareness ›› Inverter control The application of inverter control saves energy for two basic reasons:
1. It enables compressor speed to vary according to the cooling/ heating load and therefore consume only the power necessary to match that load. The 50 Hz frequency of the power supply is inverted to a higher or lower frequency according to the required capacity to heat or cool the room. If a lower capacity is needed, the frequency is decreased and less energy is used. 2. Under partial load conditions, the energy efficiency is higher. If the compressor rotates more slowly because less capacity is needed, the coil becomes virtually oversized. Improved efficiencies can therefore be achieved than are possible with non inverter compressors, which always run at the same speed.
Slow start Temperature remains stable
Air conditioning with Inverter
Air conditioning without Inverter
›› High COP values A major feature of VRV®III-S is its exceptional energy efficiency, the system achieving high COPs during both cooling and heating operation by the use of refined components and functions.
Nominal value *3.99
1
*1 Nominal cooling capacities are based on: indoor temperature: 27°CDB,
Cooling
19°CWB, inlet water temperature: 30°C, equivalent refrigerant piping: 7.5m, level difference: 0m.
2
Unit: RXYSQ4PA7V1B *2 Nominal heating capacities are based on: indoor temperature: 20°CDB,
*4.56
Heating
outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 7.5m, level difference: 0m.
Unit: RXYSQ4PA7V1B 5
10
4
3
2
1
0
3. Installation & Maintenance Friendly Design ›› Automatic Charge Function ››
Conventional Way: 1. calculation of additional refrigerant charging volume 2. charging the unit with additional refrigerant 3. measuring the weight of the cylinder 4. judgment based on pressure (test operation)
››
VRV®III-S: With VRV®III however, these 4 steps are omitted since VRVIII®-S can be charged with the necessary amount of refrigerant automatically via a push button on the PCB. Automatic charging will cease once the appropriate amount of refrigerant has been transferred. If temperature drops below 20°C manual charging is necessary (to avoid overcharging the system). After having switched to heating and once the indoor temperature rises above 20°C, push the auto charge button to initialise auto charge function. Refrigerant containment is only available after performing the automatic charge function.
Indoor temperature 32°C 20°C
Automatic charge function
Manual charge*
0°C
43°C
Outdoor temperature *To avoid overcharging the system
›› Automatic Test When refrigerant charging has ceased, pushing the test operation button on the PCB will initiate a check on the wiring, shut off valves, sensors and refrigerant volume. This test ceases automatically when completed.
11
›› Simple wiring and piping connection
▼
▼t
▼t
▼t
▼t
▼t
– simple wiring ›› Super Wiring allows the shared use of wiring between indoor units, outdoor units and the centralised remote controls. ›› This system makes it easy for the user to retrofit the existing system with a centralised remote control, simply by connecting it to the outdoor units. ›› The use of non polarity wiring, makes incorrect connection impossible and reduces installation time.
– piping connection ›› The unified Daikin REFNET piping system is specially designed for simple installation. ›› REFNET joints and headers (both accessories) can cut down on installation work and increase system reliability.
12
Outdoor Units
5 2 1
1. VRV®III-S technology
3 4
1 Smooth air inlet bell mouth and aero spiral fan These features assist in significantly reducing noise. Guides are added to the bell mouth intake to reduce turbulence in the air flow generated by fan suction. The aero spiral fan features fan blades with bent blade edges, further reducing turbulence.
Aero spiral fan blade tips
➔ Conventional
➔ New
Escaping edges are sucked in by the bent blade edges, reducing overall turbulence. DC motor efficiency )comparison with a conventional AC motor(
2 DC fan motor The use of a DC fan motor offers substantial improvements in operating efficiency compared to conventional AC motors, especially during low speed rotation.
)%( Efficiency
100
Approx. 20% increase
80 60
DC motor
40
AC motor 20
3 Super aero grille The spiral shaped ribs are aligned with the direction of discharge flow in order to minimise turbulence and reduce noise.
DC fan motor structure
magnet
Approx. 40% increase
0 200 300 400 500 600 700 800 900 1000
Motor speed (rpm)
Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory
Reluctance brushless DC compressor 4 The reluctance brushless DC motor provides significant increases in efficiency compared to conventional AC inverter motors, simultaneously using two different forms of torque (normal and reluctance torque) to produce extra power from small electric currents.
Iron
n n S
Suction
n S
S n S n
S Neodymium magnet
n
Rotating stator field
Low pressure side
Discharge
Normal” torque“ Reluctance torque
High pressure side
n S
Scroll
Reluctance DC Motor
n S
S n S n
S
›› Powerful magnets The motor comprises powerful neodymium magnets that create the reluctance torque. These magnets are approximately 12 times stronger than ferrite types and make a major contribution to its energy saving characteristics.
Neodymium magnet
Ferrite magnet
13
›› Smooth sine wave DC inverter Optimizing the sine wave curve results in smoother motor rotation and improved motor efficiency. ›› Optimal refrigerant configuration Changes to the shape of the spiral and volume ratio result in optimal refrigerant layout.
5
›› Stronger materials The strength of the casing has been increased by boosting the internal dome pressure.
2 1
3 4
5 e-Bridge circuit Prevents accumulation of liquid refrigerant in the condenser. This results in more efficient use of the condenser surface under all conditions and leads in turn to better energy efficiency. Increased evaporative capacity stems from the newly developed refrigeration circuit, the SCebridge circuit, which adds super cooling prior to the expansion cycle. By adopting this circuit, the COPs in both cooling and heating have been drastically improved.
Current Evaporativecapacity
By the SCe- bridge circuit, cooling and heating attain the improvement in COP
Evaporative-capacity has been improved by adopting the SCe-Bridge Circuit circuit. SCe-Bridge Circuit
Current Model
6 e-Pass heat exchanger Optimization of the layout path of the heat exchanger prevents heat transferring from the overheated gas section towards the sub cooled liquid section, a more efficient use of the heat exchanger.
Evaporative capacity can be raised by taking super cooling just before the electronic expansion valve
HD Type
OUT 45°C IN 85°C
IN 85°C
OUT 45°C
55°C
27°C
27°C
55°C
27°C
60°C
27°C
50°C
27°C
55°C
27°C
55°C
37°C
43°C
OUT 45°C
7 i-Demand function The newly introduced current sensor minimizes the difference between actual power consumption and predefined power consumption.
14
Power consumption (KVV)
In cooling mode, the heat exchanger of the condensor is improved. This means an improvement of COP by 3%.
20:00
16:00 12:00 Time
8:00
2. Specifications RXYSQ4PA7V1B / RXYSQ4PA7Y1B Nominal capacity COP
cooling heating cooling heating
Capacity range Max n° of indoor units to be connected minimum Indoor index connection maximum colour Casing material Power supply Dimensions unit
Weight Fan
Compressor Operation range
Sound level (nominal)
Refrigerant
Refrigerant Oil Piping Connections
kW kW
HP
height width depth
unit type air Flow Rate cooling (nominal at 230V) heating type starting method minimum cooling maximum minimum heating maximum sound power cooling sound pressure heating sound pressure type charge control type charged Volume liquid diameter (OD) gas diameter (OD) heat Insulation max. total length
V3 mm mm mm kg m/min m/min
°CDB °CDB °CWB °CWB dBA dBA dBA kg
l mm mm m
Safety devices
RXYSQ5PA7V1B / RXYSQ5PA7Y1B
RXYSQ6PA7V1B / RXYSQ6PA7Y1B
11.2 12.5 3.99 / 3.88 4.56 / 4.43 4 6 50 130
14.0 15.5 16.0 18.0 3.99 / 3.88 3.42/ 3.33 4.15 / 4.03 3.94 / 3.83 5 6 8 9 62.5 70 162.5 182 daikin white painted galvanised steel 1~, 50Hz, 220-240V / 3~, 50Hz, 380-415V 1,345 1,345 1,345 900 900 900 320 320 320 125/120 125/120 125/120 Propeller 106 106 106 102 105 105 hermetically sealed scroll compressor direct on line -5.0 -5.0 -5.0 46 46 46 -20 -20 -20 15.5 15.5 15.5 66 67 69 50 51 53 52 53 55 R-410A 4.0 4.0 4.0 expansion valve (electronic type) daphne FVC68D 1.5 1.5 1.5 9.52 (Flare) 9.52 (Flare) 9.52 (Flare) 15.9 (Flare) 15.9 (Flare) 19.1 (Braze) both liquid and gas pipes 300 300 300 HPS, fan motor thermal protection, inverter overload protector, PC board fuse
Notes: Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, inlet water temperature: 30°C, equivalent refrigerant piping: 7.5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 7.5m, level difference: 0m. Sound power level is an absolute value that a sound source generates. Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to sound level drawings. Sound values are measured in a semi-anechoic room.
3. Accessories RXYSQ4PA7V1B / RXYSQ4PA7Y1B Cool/heat selector Fixing box Refnet headerr Refnet joint Central drain plug
RXYSQ5PA7V1B / RXYSQ5PA7Y1B
RXYSQ6PA7V1B / RXYSQ6PA7Y1B
KRC19-26A6 KJB111A KHRQ22M29H KHRQ22M20T KKPJ5F180
15
Indoor Units 1. Features FXFQ-P 20-25-32-40-50-63-80100-125
Round Flow ceiling mounted cassette Comfort ›› Modern style decoration panel in white (RAL9010) ›› 360° air discharge ensures uniform air flow and temperature distribution ›› Air discharge from the corners avoids dead zones that may be subject to temperature differences ›› Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling ›› 23 different air flow patterns possible ›› Fresh air intake: up to 20% Flexible installation and easy maintenance ›› Reduced installation height: 214mm for class 20-63 ›› Easy visible drain check thanks to clear drain socket ›› Drain-up pump with 850 mm lift fitted as standard
850 mm
Examples of Airflow Patterns
360° Round Flow
FXZQ-M8 20-25-32-40-50
4-Way Flow
3-Way Flow
2-Way Flow
4-Way blow ceiling mounted cassette (600mmx600mm) Comfort Ceiling void ›› Modern style decoration panel in white (RAL9010) is 295 mm ›› Extremely quiet in operation 0° ›› Excellent low draught characteristics. Since the flaps can move to 60° a 0° position, virtually no draught can be experienced ›› Any one of 5 different air flow patterns can be freely selected between 0° and 60° and will then be maintained during the operational cycle of the air conditioner Flexible Installation and Easy Maintenance ›› Thanks to the compact casing, it matches standard architectural modules of 600x600mm, therefore ceiling tile cutting is no longer necessary ›› Air can be discharged in any of 4 directions ›› Possibility to shut 1 or 2 flaps for easy installation in corners ›› Since the switch box is located within the unit, it is easy to access from below for maintenance without removing ceiling tiles ›› Drain-up pump with 500mm lift fitted as standard
16
500mm
FXCQ-M8 20-25-32-40-50-6380-125
2-Way blow ceiling mounted cassette Comfort ›› Quiet in operation ›› Leaves maximum floor and wall space for furniture, decorations and fittings ›› Automatic air flow director ensures uniform air flow and temperature distribution ›› Anti-ceiling soiling technology Filter ›› Standard long life filter Flexible Installation and Easy Maintenance ›› Easy installation in false ceilings of only 355mm ›› Drain-up pump with 600mm lift fitted as standard ›› Maintenance can be performed by simply removing the front panel ›› Easy to clean flat suction grille ›› Detachable swing flaps
FXKQ-MA 20-32-40-63
minimum ceiling height is 355mm
600mm 600mm
Ceiling mounted corner cassette Comfort ›› Equipped with special draught prevention and anti-ceiling soiling technology 1
Standard
2
Draught prevention
3
Anti-ceiling soiling technology
Note: Standard setting when shipped.
›› Automatic air flow director ensures uniform air flow and temperature distribution ›› Air flow by either downward air discharge, frontal discharge or a combination of both Downward discharge
Frontal discharge
Combination
Closed by the decoration panel
Flexible Installation ›› Compact dimensions, can easily be mounted in a narrow ceiling void (only 220mm ceiling space required, 195 with panel spacer, available as accessory)
Panel spacer
Min. 195 mm 20 mm
500 mm
›› Drain-up pump with 500mm lift fitted as standard
17
FXDQ-M8 20-25
Small concealed ceiling unit Comfort ›› Designed for hotel bedrooms ›› Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible ›› Extremely quiet in operation Filter ›› Air suction filter fitted as standard Flexible Installation ›› Compact dimensions (230mm high & 652mm deep), can easily be mounted in a ceiling void ›› The air suction direction can be altered from rear to bottom suction ›› For easy mounting, the drain pan can be located to the left or the right of the unit
FXDQ-P/NA 20-25-32-40-50-63
Slim concealed ceiling unit Comfort ›› Quiet in operation ›› Blends unobtrusively with any interior décor ›› Leaves maximum floor and wall space for furniture, decorations and fittings Flexible Installation ›› Slim design, can easily be mounted in a ceiling void of only 240mm
200mm
Air filter Suction Chamber [Duct connection]
›› Can be installed in both new and existing buildings ›› Medium external static pressure facilitates unit use with flexible ducts of varying lengths ›› Drain-up pump with 750mm lift fitted as standard
Ceiling
18
FXSQ-M8 20-25-32-40-50-6380-100-125
Concealed ceiling unit Comfort ›› High flexibility for a wide variety of applications ›› Quiet in operation ›› Blends unobtrusively with any interior décor Filter ›› Long life filter fitted as standard ›› High efficiency filters (65% and 95%) available as accessory Flexible Installation and Easy Maintenance ›› High external static pressure facilitates unit use with flexible ducts of varying lengths ›› When using suction panel, unit requires only 350mm of ceiling space ›› Drain-up pump with 625mm lift fitted as standard ›› The air suction direction can be altered from rear to bottom suction ›› The switch box can be reached from the side or from the bottom side of the unit for easy servicing
FXMQ-P 40-50-63-80-100-125
Min. 350mm
625mm
625mm
Concealed ceiling unit Comfort ›› Leaves maximum floor and wall space for furniture, decorations and fittings Flexible Installation ›› Compact unit (a height of 300 mm), allows installation in narrow ceiling voids ›› Complete range of models (FXMQ-PVE: 4.5 - 14 kW) (FXMQ-MAVE: 22.40 - 28 kW) ›› Built-in drain pump (standard for sizes 40 to 125) increases reliability of the drain system ›› Reduction of power consumption of 20 % (compared to FXMQ-MAVE series) through use of new DC Fan ›› Possibility to change ESP through wired remote control allows optimisation of the supply air volume
19
FXAQ-MA 20-25-32-40-50-63
Wall mounted unit
10° 10°
Comfort ›› Compact and stylish design blends unobtrusively in any interior décor ›› Automatic air flow director ensures efficient air distribution via louvers that close automatically when the unit is switched off ›› 5 different discharge angles can be programmed via the remote control ›› Discharge angle automatically returns to its previous position on restart (initial setting 10 degrees for cooling and 70 degrees for heating)
70° 70°
10° 10° 25° 25° 40° 40° 55° 55° 70° 70°
10° Cooling 70° Heating
Filter ›› Mildew proof polystyrene filter and drain pan Flexible Installation and Easy Maintance ›› Both horizontal flaps and front panel can easily be removed and washed ›› All maintenance operations can be carried out from the front of the unit ›› Drain-up pump with 1,000mm lift available as accessory ›› Drain pipe can be fitted either to the left or right side of the unit Height of drain-up
1,000mm
Drain-up kit
FXHQ-MA 32-63-100
Indoor unit
Drain-up kit
Slim concealed ceiling unit Comfort ›› Quiet in operation ›› Leaves maximum floor and wall space for furniture, decorations and fittings ›› Enhanced horizontal and vertical air circulation in all directions thanks to an air flow pattern of 100° 100°
Filter ›› Long life filter fitted as standard Flexible Installation and Easy Maintance ›› Can be installed in both new and existing buildings ›› The ideal solution for installation without false ceilings ›› Drain-up pump with 600mm lift available as accessory Drain-up kit (built inside main unit)
›› Maintenance can be performed easily from below the unit ›› Bristle free flap makes cleaning easier
20
FXUQ-MA 71-100-125
4-way blow ceiling suspended unit Comfort ›› Group control with other VRV indoor units possible ›› Cool heat selection ›› Prevention of cold draught at hot start, defrost and oil return in heating ›› Air can be discharged in any of 4 directions ›› Air can be discharged at 5 different angles between 0 and 60 degrees
›› Automatic air flow director ensures efficient air and temperature distribution. ›› Air flow distribution for ceiling heights up to 3.5m without loss of capacity.
Filter ›› Air filter, drain pan and heat exchanger fin are mildew proof and anti-bacterial treated Flexible Installation ›› Ideal for installation in new and existing buildings ›› 5m maximum distance between FXUQ unit and junction box ›› Possibility to shut 1 or 2 flaps for easy installation in corners ›› Drain-up pump with 500mm lift fitted as standard
21
FXLQ-MA 20-25-32-40-50-63
Floor standing unit Comfort ›› Ideal for installation beneath a window ›› Compact dimensions (only 222mm deep and 600mm high) ›› All models are available with remote control Filter ›› Long life filter fitted as standard Flexible Installation and Easy Maintance ›› Running the pipes from connections at the back, enables the unit to be wall mounted
Wall mounted
Floor standing
›› On site connection during installation is easier ›› The fibreless discharge grille prevents condensation and staining
FXNQ-MA 20-25-32-40-50-63
Concealed floor standing unit Comfort ›› Ideal for perimeter air conditioning ›› Ideal for installation below a window ›› All models are available with remote control Filter ›› Long life filter fitted as standard Flexible Installation and Easy Maintance ›› On site connection during installation is easier ›› The connecting port faces downward, eliminating the need to attach auxiliary piping
Connecting port
Refrigerant piping
22
2. specifications & accessories
FXFQ-P Roundflow ceiling mounted cassette
specifications FXFQ-P Capacity Power input Dimensions Weight Casing Air Flow Rate Sound power (nominal) Sound pressure Refrigerant Power Supply Piping Connections Air Filter Drain-up Height Decoration Panel
cooling heating cooling heating (H x W x D) unit
kW kW kW kW mm kg
cooling heating cooling cooling heating name
high / low high / low high / low high / low
m3 /min m3 /min dB(A) dB(A) dB(A)
L / G / D
diameter
mm
20
25
32
2.2 2.5
2.8 3.2 0.053 0.045
3.6 4.0
40
20.0 12.5 / 9.0 12.5 / 9.0 49 31 / 28 31 / 28
6.35 / 12.7 / 32
13.5 / 9.0 13.5 / 9.0 50 32 / 28 32 / 28
63
80
5.6 6.3 0.083 0.067
7.1 8.0 0.095 0.114
21.0 Galvanised steel 15.5 / 10.0 15.0 / 9.5 51 33 / 28 33 / 28 R-410A 1~ / 220-240V / 50Hz
9.0 11.2 10.0 12.5 0.120 0.173 0.108 0.176 246 x 840 x 840 24.0
16.5 / 11.0 17.5 / 12.0 52 34 / 29 36 / 30
100
23.5 / 14.5 23.5 / 14.5 55 38 / 32 38 / 32
6.4 / 12.7 / 32
26.5 / 17.0 28.0 / 17.5 58 41 / 33 42 / 34
125 14.0 16.0 0.258 0.246 288 x 840 x840 26.0 33.0 / 20.0 33.0 / 20.0 61 44 / 34 44 / 34
9.5 / 15.9 / 32 Resin net with mold resistance 750 BYCQ140CW1 RAL9010 50x950x950 5.5
mm model colour (H x W x D) weight
50
4.5 5.0 0.063 0.055 204 x 840 x 840
mm kg
Notes: The sound pressure values are mentioned for a unit installed with rear suction The sound power level is an absolute value indicating the power wich a sound source generates. Nominal cooling capacities are based on: indoor temperature: 270CDB, 190CWB, outdoor temperature: 350CDB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
Accessories FXFQ-P Wired remote control Infrared remote control
20 cooling only heat pump
Decoration panel Replacement long life filter (non-woven type) Fresh air intake kit (20 % fresh air intake) (chamber type) Air discharge outlet sealing member
25
32
40
50
63
80
125
BRC1D52 BRC7F533F BRC7F532F BYCQ140CW1 KAFP551K160 KDDQ5C140 KDBHQ55C140
23
FXZQ-M8 4-way blow ceiling mounted cassette (600mm x 600mm)
specifications FXZQ-M8 Cooling capacity Heating capacity Nominal input Dimensions (H x W x D) Weight Casing Air flow rate (H / L) Sound pressure level (H / L) (220V) Sound power level Refrigerant type Piping connections Air filter Drain-up height Power supply Decoration panel
kW kW W W mm kg
cooling heating
m3 /min dB(A) dB(A) liquid / gas
dimensions (H x W x D) weight Colour
20
25
32
40
50
2.2 2.5 73 64
2.8 3.2 73 64
4.5 5.0 89 80
5.6 6.3 115 107
9.0 / 7.0 30 / 25 47
9.0 / 7.0 30 / 25 47
3.6 4.0 76 68 286 x 575 x 575 18 galvanised steel plate 9.5 / 7.5 32 / 26 49 R-410A ø6.4 / ø12.7 resin net with mold resistant 500 1~, 50Hz, 220-240V 55 x 700 x 700 2.7 white (RAL 9010)
11.0 / 8.0 36 / 28 53
14.0 / 10.0 41 / 33 58
mm mm V1 mm kg
Notes: Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB • outdoor temperature: 35°CDB • equivalent piping length: 7.5m (horizontal). Nominal heating capacities are based on: indoor temperature: 20°CDB • outdoor temperature: 7°CDB, 6°CWB • equivalent piping length: 7.5m (horizontal). Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
Accessories FXZQ-M8 Wired remote control Infrared remote control Decoration panel Sealing member of air discharge outlet Panel spacer Replacement long life filter Fresh air intake kit
24
20 cooling only heat pump
direct installation type
25
32 BRC1D52 BRC7E531 BRC7E530 BYFQ60B KDBH44B60 KDBQ44B60 KAFQ441B60 KDDQ44X60
40
50
FXCQ-M8 2-way blow ceiling mounted cassette
specifications FXCQ-M8 Cooling capacity Heating capacity Nominal input Dimensions (H x W x D) Weight Casing Air flow rate (H / L) Sound pressure level (H / L) Sound power level Refrigerant type Piping connections Air filter Drain-up height Power supply Decoration panel
cooling heating
kW kW W W mm kg m3 /min dB(A) dB(A)
liquid / gas
dimensions (H x W x D) weight colour
20
25
32
40
50
63
80
125
2.2 2.5 77 44
2.8 3.2 92 59 305 x 780 x 600 26
3.6 4.0 92 59
4.5 5.0 130 97
5.6 6.3 130 97
7.1 8.0 161 126 305 x 1,180 x 600 35
9.0 10.0 209 176
14.0 16.0 256 223
47
48
9 / 6.5 35 / 29 50
9 / 6.5 35 / 29 50
16.5 / 13 38 / 33 52
26 / 21 40 / 35 54
33 / 25 45 / 39 60
7 / 5 33 / 28 45
305 x 995 x 600 31
32 galvanised steel plate 12 / 9 12 / 9 35.5 / 30.5 35.5 / 30.5 50 50 R-410A
ø6.4 / ø12.7
mm mm V3 mm kg
ø9.5 / ø15.9 resin net with mold resistant 600 1~, 50Hz, 230V 53 x 1,245 x 680 8.5 ivory white
53 x 1,030 x 680 8
305 x 1,670 x 600
53 x 1,430 x 680 9.5
53 x 1,920 x 680 12
Notes: Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB • outdoor temperature: 35°CDB • equivalent refrigerant piping: 8m • level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB • outdoor temperature: 7°CDB, 6°CWB • equivalent refrigerant piping: 8m • level difference: 0m. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
Accessories FXCQ-M8 Wired remote control Infrared remote control Decoration panel High efficiency filter 65% *1 High efficiency filter 90% *1 Filter chamber for bottom suction Replacement long life filter
20
25
cooling only heat pump BYBC32G KAFJ532G36 KAFJ533G36 KDDFJ53G36 KAFJ531G36
32
40
50 BRC1D52 BRC7C67 BRC7C62 BYBC50G KAFJ532G56 KAFJ533G56 KDDFJ53G56 KAFJ531G56
63
BYBC63G KAFJ532G80 KAFJ533G80 KDDFJ53G80 KAFJ531G80
80
125
BYBC125G KAFJ532G160 KAFJ533G160 KDDFJ53G160 KAFJ531G160
Note: *1. Filter chamber is required when installing a high efficiency filter.
25
FXKQ-MA Ceiling mounted corner cassette
specifications FXKQ-MA Cooling capacity Heating capacity Nominal input
cooling heating
Dimensions (H x W x D) Weight Casing Air flow rate (H / L) Sound pressure level (H / L) (220V) Sound power level Refrigerant type Piping connections liquid / gas Air filter Drain-up height Power supply dimensions (H x W x D) Decoration panel weight colour
kW kW W W mm kg
25
32
40
63
2.8 3.2 66 46
3.6 4.0 66 46 215 x 1,110 x 710 31
4.5 5.0 76 56
7.1 8.0 105 85 215 x 1,310 x 710 34
11 / 9 38 / 33 *
11 / 9 38 / 33 *
13 / 10 40 / 34 *
18 / 15 42 / 37 *
galvanised steel plate m3 /min dB(A) dB(A)
R-410A ø6.4 / ø12.7
mm
ø9.5 / ø15.9 resin net with mold resistant 500 1~, 50Hz, 220-240V
mm VE mm kg
70 x 1,240 x 800 8.5
70 x 1,440 x 800 9.5 ivory white
Notes: Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB • outdoor temperature: 35°CDB • equivalent refrigerant piping: 7.5m (horizontal). Nominal heating capacities are based on: indoor temperature: 20°CDB • outdoor temperature: 7°CDB, 6°CWB • equivalent refrigerant piping: 7.5m (horizontal). Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. *Data were not available at time of publication.
Accessories 25
FXKQ-MA Wired remote control Infrared remote control Decoration panel Panel spacer Replacement long life filter Air discharge grille Air discharge blind panel Flexible duct (with shutter)
26
32
40
63
BRC1D52 BRC4C63 BRC4C61
cooling only heat pump BYK45F KPBJ52F56 KAFJ521F56 K-HV7AW KDBJ52F56W KFDJ52F56
BYK71F KPBJ52F80 KAFJ521F80 K-HV9AW KDBJ52F80W KFDJ52F80
FXDQ-M8 Small concealed ceiling unit
specifications FXDQ-M8 Cooling capacity Heating capacity Nominal input )Dimensions (HxWxD Weight Casing )Air flow rate (H/L )Sound pressure level (H/L Sound power level Refrigerant type Piping connections Air filter Power supply
cooling heating
kW kW W W mm kg m3/min )dB(A )dB(A
liquid/gas
20
25
2.2 2.5
2.8 3.2 50 50 230x502x652 17 galvanised steel plate
6.7/5.2
7.4/5.8 37/32 50 R-410A ø6.4/ø12.7 resin net with mold resistant 50Hz, 230V ,~1
mm V3
Notes : Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB • outdoor temperature: 35°CDB • equivalent refrigerant piping: 8m • level difference : 0m Nominal heating capacities are based on: indoor air temperature: 20°CDB • outdoor temperature: 7°CDB, 6°CWB • equivalent refrigerant piping: 8m • level difference : 0m Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
Accessories FXDQ-M8 Wired remote control Infrared remote control
20 cooling heating
25 BRC1D52, BRC2C51, BRC3A61 BRC4C64 BRC4C62
27
FXDQ-P / NA Slim concealed ceiling unit
specifications FXDQ-P / NA Cooling capacity Heating capacity Nominal input Dimensions (H x W x D) Weight Casing Air flow rate (H / L) Sound pressure level (H / L) Sound power level Refrigerant type Drain-up height Piping connections Air filter Power supply
cooling heating
kW kW W W mm kg m3 /min dB(A) dB(A)
liquid / gas
FXDQ20P
FXDQ25P
FXDQ32P
2.2 2.5 86 67
3.6 4.0 89 70
23
2.8 3.2 86 67 200 x 700 x 620 23
8.0 / 6.4 33 / 29 *
8.0 / 6.4 33 / 29 *
mm mm VE
FXDQ40NA
4.5 5.0 160 70 200 x 900 x 620 23 27 galvanised steel plate 8.0 / 6.4 10.5 / 8.5 33 / 29 34 / 30 * * R-410A 750 ø6.4 / ø12.7 removable, washable, mildew proof 1~, 50Hz, 220-240V
FXDQ50NA
FXDQ63NA
5.6 6.3 165 152 28
7.1 8.0 181 168 200 x 1,100 x 620 31
12.5 / 10.0 35 / 31 *
16.5 / 13.0 36 / 32 *
ø9.5 / ø15.9
Notes: Nominal cooling capacities are based on: • Indoor temperature: 27°CDB, 19°CWB • Outdoor temperature: 35°CDB • Equivalent piping length: 7.5m (horizontal). Nominal heating capacities are based on: • Indoor temperature: 20°CDB • Outdoor temperature: 7°CDB, 6°CWB • Equivalent piping length: 7.5m (horizontal). Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. The sound pressure values are mentioned for a unit installed with rear suction. * Data were not available at time of publication.
Accessories FXDQ-P / NA Wired remote control Infrared remote control
28
FXDQ20P cooling only heat pump
FXDQ25P
FXDQ32P
FXDQ40NA BRC1D52 BRC4C64 BRC4C62
FXDQ50NA
FXDQ63NA
FXSQ-M8 Concealed ceiling unit
specifications FXSQ-M8 Cooling capacity Heating capacity Nominal input Dimensions (H x W x D) Weight Casing Air flow rate (H / L) Sound pressure level (H / L) Sound power level Refrigerant type Piping connections Air filter Drain-up height Power supply Decoration panel
kW kW W W mm kg
cooling heating
m3 /min dB(A) dB(A) liquid / gas
20
25
2.2 2.5 110 90 300 x 550 x 800 30
2.8 3.2 110 90 300 x 700 x 800 30
9 / 6.5 32 / 28 50
9 / 6.5 32 / 28 50
mm
32
40
3.6 4.5 4.0 5.0 114 127 94 107 300 x 1,000 x 800 300 x 1,400 x 800 30 30 9.5 / 7 33 / 28 51
11.5 / 9 33 / 29 56
50
63
80
100
125
5.6 6.3 143 123
7.1 8.0 189 169
9.0 10.0 234 214
11.2 12.5 242 222
14.0 16.0 321 301
31 galvanised steel plate 15 / 11 35 / 31 58 R-410A
41
51
51
52
21 / 15.5 35 / 30 56
27 / 20 37 / 31 55
28 / 20.5 38 / 33 56
38 / 28 40 / 35 65
ø6.4 / ø12.7
ø9.5 / ø15.9 resin net with mold resistant 625 1~, 50Hz, 230V 55 x 800 x 500 55 x 1,100 x 500 3.5 4.5 ivory white
mm V3 dimensions (H x W x D) weight kg colour
55 x 650 x 500 3
55 x 1,500 x 500 6.5
Notes: Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB • outdoor temperature: 35°CDB • equivalent refrigerant piping: 8m • level difference: Om. Nominal heating capacities are based on: indoor temperature: 20°CDB • outdoor temperature: 7°CDB, 6°CWB • equivalent refrigerant piping: 8m • level difference: Om. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. The sound pressure values are mentioned for a unit installed with rear suction.
Accessories 20
FXSQ-M8 Wired remote control Infrared remote control Decoration panel Service access panel High efficiency filter 65% *1 High efficiency filter 90% *1 Filter chamber for bottom suction Filter chamber rear suction Air suction canvas Screening door / blind board Air discharge adapter for round duct
25
cooling only heat pump BYBS32D KTBJ25K36W KAFJ252L36 KAFJ253L36 KAJ25L36D KAJ25L36B KSA-25K36 KBBJ25K36 KDAJ25K36
32
40
50
63
BRC1D52, BRC2C51, BRC3A61 BRC4C64 BRC4C62 BYBS45D BYB571D KTBJ25K56W KTBJ25K80W KAFJ252L56 KAFJ252L80 KAFJ253L56 KAFJ253L80 KAJ25L56D KAJ25L80D KAJ25L56B KAJ25L80B KSA-25K56 KSA-25K80 KBBJ25K56 KBBJ25K80 KDAJ25K56 KDAJ25K71
80
100
125
BYBS125D KTBJ25K160W KAFJ252L160 KAFJ253L160 KAJ25L160D KAJ25L160B KSA-25K160 KBBJ25K160 KDAJ25K140
Notes: *1. If installing a high efficiency filter in the unit, an assembly chamber for either bottom or rear suction is required.
29
FXMQ-P Concealed ceiling unit
specifications FXMQ-P Cooling capacity Heating capacity Nominal input Dimensions (H x W x D) Weight Casing Air flow rate (HH / H / L) Sound pressure level Sound power level Refrigerant type Piping connections Air filter Power supply
cooling heating
kW kW W W mm kg m3 /min dB(A) dB(A)
liquid / gas
mm
40
50
4.5 5.0 0.194(1) / 0.193(2) 0.182 300 x 700 x 700 28
5.6 6.3 0.215(1) / 0.214(2) 0.203
16/13/11 note 3 note 3
18/16.5/15 note 3 note 3
36
ø6.4 / ø12.7
VE
63
80
7.1 9.0 8.0 10.0 0.230(1) / 0.229(2) 0.298(1) / 0.297(2) 0.218 0.286 300 x 1,000 x 700 36 36 galvanised steel plate 19.5/17.5/16 25/22.5/20 note 3 note 3 note 3 note 3 R-410A ø9.5 / ø15.9 note 4 1~, 50Hz, 220-240V / 1~, 60Hz, 220V
100
125
11.2 14.0 12.5 16.0 0.376(1) / 0.375(2) 0.461(1) / 0.460(2) 0.364 0.449 300 x 1,400 x 700 46 46 32/27/23 note 3 note 3
39/33/28 note 3 note 3
Notes: Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB • outdoor temperature: 35°CDB • equivalent refrigerant piping: 5m (horizontal). Nominal heating capacities are based on: indoor temperature: 20°CDB • outdoor temperature: 7°CDB, 6°CWB • equivalent refrigerant piping: 5m (horizontal). Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (1) 50Hz, 220-240V (2) 60Hz, 220V (3) Data were not available at time of publication. (4) The air filter is not standard accessory, but please mount it in the duct system at the suction side. Select its colorimetric method (gravity method) 50% or more.
Accessories FXMQ-P Wired remote control Infrared remote control High efficiency filter 65% High efficiency filter 90% Filter chamber Longlife replacement filter
30
40
50
63
80
100
125
BRC1D52 BRC4C66 BRC4C65
cooling only heat pump KAF372AA56 KAF373AA56 KDDF37AA56 KAF371AA56
KAF372AA80 KAF373AA80 KDDF37AA80 KAF371AA80
KAF372AA160 KAF373AA160 KDDF37AA160 KAF371AA160
FXAQ-MA Wall mounted unit
specifications FXAQ-MA Cooling capacity capacity Nominal input Dimensions (HxWxD) Weight Colour Air flow rate (H / L) Sound pressure level (H / L) (220V) Sound power level Refrigerant type Piping connections Air filter Power supply
cooling heating
kW kW W W mm kg
20
25
32
40
50
63
2.2 2.5 16 24
2.8 3.2 22 27 290 x 795 x 230 11
3.6 4.0 27 32
4.5 5.0 20 20
5.6 6.3 27 32 290 x 1,050 x 230 14
7.1 8.0 50 60
7.5 / 4.5 35 / 29 *
8 / 5 36 / 29 *
9 / 5.5 37 / 29 *
12 / 9 39 / 34 *
15 / 12 42 / 36 *
19 / 14 46 / 39 *
white m3 /min dB(A) dB(A)
R-410A ø6.4 / ø12.7
liquid / gas mm
ø9.5 / ø15.9
resin net washable 1~, 50Hz, 220-240V
VE
Notes: Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB • outdoor temperature: 35°CDB • equivalent refrigerant piping: 5m (horizontal). Nominal heating capacities are based on: indoor temperature: 20°CDB • outdoor temperature: 7°CDB, 6°CWB • equivalent refrigerant piping: 5m (horizontal). Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. *Data were not available at time of publication.
Accessories FXAQ-MA Wired remote control Infrared remote control Drain pump kit
20 cooling only heat pump
25
32
40
50
63
BRC1D52 BRC7E619 BRC7E618 K-KDU572DVE
31
FXHQ-MA Ceiling suspended unit
specifications FXHQ-MA Cooling capacity Heating capacity Nominal input Dimensions (HxWxD) Weight Colour Air flow rate (H / L) Sound pressure level (H / L) (220V) Sound power level Refrigerant type Piping connections Air filter Power supply
cooling heating
kW kW W W mm kg m3 /min dB(A) dB(A)
liquid / gas
mm
32
63
100
3.6 4.0 111 111 195 x 960 x 680 24
7.1 8.0 115 115 195 x 1,160 x 680 28 ivory white 17.5 / 14 39 / 34 * R-410A
11.2 12.5 135 135 195 x 1,400 x 680 33
12 / 10 36 / 31 * ø6.4 / ø12.7
25 / 19.5 45 / 37 * ø9.5 / ø15.9
resin net with mold resistant 1~, 50Hz, 220-240V
VE
Notes: Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB • outdoor temperature: 35°CDB • equivalent refrigerant piping: 7.5m (horizontal). Nominal heating capacities are based on: indoor temperature: 20°CDB • outdoor temperature: 7°CDB, 6°CWB • equivalent refrigerant piping: 7.5m (horizontal). Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. *Data were not available at time of publication.
Accessories FXHQ-MA Wired remote control Infrared remote control Drain pump kit Replacement long life filter L-type piping kit
32
32
63
100
KDU50M60 KAFJ501DA56 KHFP5M35
BRC1D52 BRC7E66 BRC7E63 KDU50M125 KAFJ501DA80 KHFP5M63
KDU50M125 KAFJ501DA112 KHFP5M63
cooling only heat pump resin net for upward direction
FXUQ-MA 4-way blow ceiling suspended unit
specifications FXUQ-MA Cooling capacity Heating capacity Nominal input Dimensions (HxWxD) Weight Colour Air flow rate (H / L) Sound pressure level (H / L) (220V) Sound power level (H) Refrigerant type Piping connections Air filter Power supply Combination with junction box
cooling heating
71
100
125
kW kW W W mm kg
8.0 9.0 180 160 165 x 895 x 895 25
14.0 14.0 289 269 230 x 895 x 895 31
dB(A)
19 / 14 40 / 35 56
mm
ø9.5 / ø15.9
11.2 12.5 289 269 230 x 895 x 895 31 white 29 / 21 43 / 38 59 R-410A ø9.5 / ø15.9 resin net with mold resistant 1~, 50Hz, 230V BEVQ100MA
dB(A)
liquid / gas
V1 BEVQ71MA
32 / 23 44 / 39 60 ø9.5 / ø15.9
BEVQ125MA
Notes: Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB • outdoor temperature: 35°CDB, 24° CWB. Nominal heating capacities are based on: indoor temperature: 20°CDB, 15° CWB • outdoor temperature: 7°CDB, 6°CWB. Capacities are net including a deduction for cooling (an addition for heating) for indoor fan motor heat.
Accessories FXUQ-MA
71
Wired remote control Infrared remote control
100
125
BRC1D52 BRC7C529 BRC7C528
cooling only heat pump Sealing member of air discharge outlet Air discharge decoration panel Vertical flap kit Replacement long life filter L-type connection piping kit
KDBHJ49F80 KDBTJ49F80 KDGJ49F80
KDBHJ49F140 KDBTJ49F140 KDGJ49F140 KAFJ495F140
KHFP49M63
KHFP49M140
JUNCTION BOX FOR CONNECTION TO VRV BEVQ-MA Dimensions Weight Casing Power supply
71 H x W x D
mm kg VE
x
100 100x350x225 3.0 galvanised steel plate 1~, 50Hz, 220-240V
125 3.5
BEVQ-MA
33
FXLQ-MA Floor standing unit
specifications FXLQ-MA Cooling capacity Heating capacity Nominal input Dimensions (H x W x D) Weight Colour Air flow rate (H/L) Sound pressure level (H/L) (220V) Sound power level Refrigerant type Piping connections Air filter Power supply
kW kW W W mm kg
cooling heating
m3 /min dB(A) dB(A) liquid/gas
20
25
32
40
50
63
2.2 2.5 49 49
2.8 3.2 49 49
3.6 4.0 90 90
4.5 5.0 90 90
5.6 6.3 110 110
7.1 8.0 110 110
600 x 1,000 x 222 25 7/6 35/32 *
600 x 1,140 x 222 30 ivory white 7/6 35/32 *
8/6 35/32 *
600 x 1,420 x 222 36 11/8.5 38/33 *
14/11 39/34 *
16/12 40/35 *
R-410A ø6.4/ø12.7 resin net with mold resistant 1~, 50Hz, 220-240V
mm VE
ø9.5/ø15.9
Notes: Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB • outdoor temperature: 35°CDB • equivalent refrigerant piping: 7.5m (horizontal). Nominal heating capacities are based on: indoor temperature: 20°CDB • outdoor temperature: 7°CDB, 6°CWB • equivalent refrigerant piping: 7.5m (horizontal). Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. *Data were not available at time of publication.
Accessories FXLQ-MA Wired remote control Infrared remote control Long life replacement filter
34
20
25
cooling only heat pump KAFJ361K28
32
40
BRC1D52, BRC2C51, BRC3A61 BRC4C64 BRC4C62 KAFJ361K45
50
63
KAFJ361K71
FXNQ-MA Concealed floor standing unit
specifications FXNQ-MA Cooling capacity Heating capacity Nominal input Dimensions (HxWxD) Weight Casing Air flow rate (H/L) Sound pressure level (H/L)(220V) Sound power level Refrigerant type Piping connections Air filter Power supply
cooling heating
kW kW W W mm kg m3/min dB(A) dB(A)
liquid/gas
20
25
32
40
50
63
2.2 2.5 49 49
2.8 3.2 49 49
3.6 4.0 90 90
4.5 5.0 90 90
5.6 6.3 110 110
7.1 8.0 110 110
600 x 1,00 x 222 25 7/6 35/32 *
600 x 1,140 x 222 30 ivory white 7/6 35/32 *
8/6 35/32 *
600 x 1,420 x 222 36 11/8.5 38/33 *
14/11 39/34 *
16/12 40/35 *
R-410A ø6.4/ø12.7 resin net with mold resistant 1~, 50Hz, 220-240V
mm VE
ø9.5/ø15.9
Notes: Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB • outdoor temperature: 35°CDB • equivalent refrigerant piping: 8m • level difference: Om. Nominal heating capacities are based on: indoor temperature: 20°CDB • outdoor temperature: 7°CDB, 6°CWB • equivalent refrigerant piping: 8m • level difference: Om. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. The sound pressure values are mentioned for a unit installed with rear suction.
Accessories FXNQ-MA Wired remote control Infrared remote control Replacement long life filter
20
25
cooling only heat pump KAFJ361K28
32
40
BRC1D52, BRC2C51, BRC3A61 BRC4C64 BRC4C62 KAFJ361K45
50
63
KAFJ361K71
35
Ventilation 1. VAM-FA8 The Daikin heat recovery ventilation system modulates the temperature and humidity of incoming fresh air to match indoor conditions. A balance is thus achieved between indoor and outdoor ambients, enabling the cooling or heating load placed on the air conditioning system to be reduced significantlyHRV units can be controlled individually or integral with the air conditioning system Daikin VRV® or Sky Air series)
Total heat exchanged foul air
Clean outdoor air
Foul indoor air
›› ›› ›› ›› ››
Total heat exchanged clean air
9 models to choose from Compact, energy saving ventilation Specially developed heat exchange element with HEP (High Efficiency Paper) Easy integration into the VRV® system Connectable to current Daikin control systems:
[iPU]
VAM-FA VENTILATION Air flow rate Sound pressure level (max.) (1) External static pressure (max.) Temperature exchange efficiency Enthalpy exchange efficiency Dimensions
Weight Duct diameter Power supply
m /h dBA Pa % % % mm mm mm kg mm VE 3
heating cooling H W D
VAM150FA 150 27/28.5 69 74 58 64 269 760 509 24 Ø 100
(1) Sound pressure level is measured in heat exchange mode.
36
VAM250FA 250 28/29 64 72 58 64 269 760 509 24 Ø 150
VAM350FA 350 32/34 98 75 61 65 285 812 800 33 Ø 150
VAM500FA 500 33/34.5 98 74 58 62 285 812 800 33 Ø 200
VAM650FA VAM800FA 650 800 34.5/35.5 36/37 93 137 74 74 58 60 63 65 348 348 988 988 852 852 48 48 Ø 200 Ø 250 1~, 50Hz, 220-240V
VAM1000FA 1,000 36/37 157 75 61 66 348 988 1,140 61 Ø 250
VAM1500FA 1,500 39.5/41.5 137 75 61 66 710 1,498 852 132 Ø 350
VAM2000FA 2,000 40/42.5 137 75 61 66 710 1,498 1,140 158 Ø 350
2. VKM-GA / VKM-GAM ›› ›› ›› ›› ››
eat purge (economiser): heat accumulated indoors H is discharged at night Integration of humidification and air conditioning into HRV unit Increased static pressure thanks to improved fan performance Individual control via HRV remote control Connectable to current Daikin control systems:
[iPU]
VKM-GAM VENTILATION, DX coil & humidifier cooling kW Fresh air conditioning load heating kW Air flow rate ultra high - high - low m /h Sound pressure level - 220V ultra high - high - low dBA Sound pressure level - 240V ultra high - high - low dBA Static pressure ultra high - high - low Pa Temperature exchange efficiency ultra high - high - low % Enthalpy exchange efficiency - cooling ultra high - high - low % Enthalpy exchange efficiency - heating ultra high - high - low % Humidifier type Humidification capacity kg/h height mm Dimensions width mm depth mm Weight kg Power supply V1 3
VKM50GAM 4.71 5.58 500 - 500 - 440 37 - 35.5 - 32 38 - 36 - 34 160 - 120 - 100 76 - 76 - 77.5 64 - 64 - 67 67 - 67- 69 2.70 387 1,764 832 102
VKM80GAM 7.46 8.79 750 - 750 - 640 38.5 - 36 - 33 40 - 37.5 - 35.5 140 - 90 - 70 78 - 78 - 79 66 - 66 - 68 71 - 71 - 73 natural evaporating humdifier 4.00 387 1,764 1,214 120 1~, 220-240V, 50Hz
VKM100GAM 9.12 10.69 950 - 950 - 820 39 - 37 - 34 40 - 38 - 35.5 110 - 70 - 60 74 - 74 - 76.5 62 - 62 - 66 65 - 65 -69
VKM80GA 7.46 8.79 750 - 750 - 640 40 - 37.5 - 34.5 41.5 - 39 - 37 170 - 120 - 80 78 - 78 - 79 66 - 66 - 68 71 - 71 - 73 387 1,764 1,214 109 1~, 220-240V, 50Hz
VKM100GA 9.12 10.69 950 - 950 - 820 40 - 38 - 35 41 - 39 - 36.5 150 - 100 - 70 74 - 74 - 76.5 62 - 62 - 66 65 - 65 -69 387 1,764 1,214 114
5.40 387 1,764 1,214 125
VKM-GA VENTILATION & DX coil cooling Fresh air conditioning load heating Air flow rate ultra high - high - low Sound pressure level - 220V ultra high - high - low Sound pressure level - 240V ultra high - high - low Static pressure ultra high - high - low Temperature exchange efficiency ultra high - high - low Enthalpy exchange efficiency - cooling ultra high - high - low Enthalpy exchange efficiency - heating ultra high - high - low height Dimensions width depth Weight Power supply
kW kW m /h dBA dBA Pa % % % mm mm mm kg V1 3
VKM50GA 4.71 5.58 500 - 500 - 440 38 - 36 - 33.5 39 - 37 - 35.5 180 - 150 - 110 76 - 76 - 77.5 64 - 64 - 67 67 - 67- 69 387 1,764 832 96
37
Powerful Selection Programmes 1. VRV® Xpress The Daikin heat recovery ventilation system modulates the Daikin has developed a new user friendly, software tool that allows rapid VRV® selection and provides a professional result in the 7 following steps: 1. Select indoor units 2. Connect outdoor units to indoor units 3. Automatic receipt of piping diagram with joints 4. Automatic receipt of wiring diagram 5. Connect appropriate centralised control systems 6. Visualise result in Microsoft Word, Microsoft Excel and AutoCAD® 7. Save project Using VRV® Xpress enables VRV® selection to be achieved in a simple, complete and professional manner. Windows95®, Windows98®, WindowsNT®, Windows2000®, WindowsXP® and WindowsVista® are registered trademarks of Microsoft corporation.
38
2. VRV® pro ›› Features: The VRV® Pro selection programme offers 3 separate modes to accommodate different design formats according to customer requirements. Multi languages are possible. 1. Expert mode: once the cooling and heating loads in the different rooms have been calculated, the software will select the most appropriate system plus an estimate of the power consumption. 2. Quick mode: based on calculated system loads, the software will select the most appropriate system. 3. Drawing mode: selecting the indoor and outdoor units from a list enables the user to design a system in no time at all. A simple to use, Daikin computerised selection programme, designed for use with Windows 95®, Windows 98®, WindowsNT®, Windows 2000®, Windows XP® and WindowsVista® systems, enables consulting engineers, design and build contractors, property developers and architects etc. to plan a Daikin air conditioning project on a step by step basis, complete with detailed drawings, bills of quantities and costs. The programme thus enables VRV® air conditioning systems to be engineered precisely and economically (without over-sizing units), thereby ensuring optimum operating cycles and maximum energy efficiency. Windows95®, Windows98®, WindowsNT®, Windows2000®, WindowsXP® and WindowsVista® are registered trademarks of Microsoft corporation.
39
User Friendly Control Systems 1. Individual control systems BRC4* BRC7*
›› Infrared remote control Operation buttons: ON / OFF, timer mode start / stop, timer mode on / off, programme time, temperature setting, air flow direction (FXHQ, FXFQ, FXCQ and FXAQ models only), operating mode, fan speed control, filter sign reset, inspection / test indication Display: Operating mode, battery change, set temperature, air flow direction (FXHQ, FXFQ, FXCQ and FXAQ models only), programmed time, inspection / test operation, fan speed
BRC2C51
›› Simplified remote control Simple, compact and easy to operate unit, suitable for use in hotel bedrooms Operation buttons: ON / OFF, operating mode selection, fan speed control, temperature setting Display: Cool / heat changeover control, Heat Recovery Ventilation (HRV) in operation, set temperature, operating mode, centralised control indication, fan speed, defrost / hot start, malfunction adjustment, operating mode selection, fan speed control, filter sign reset, inspection test / operation
BRC3A61
›› Simplified built-in remote control for hotel applications Compact, user friendly unit, ideal for use in hotel bedrooms Operation buttons:
ON / OFF, fan speed control, temperature setting
Display: Heat Recovery Ventilation (HRV) in operation, set temperature, operating mode, centralised control indication, fan speed, defrost / hot start, malfunction
40
›› Wired remote control ››
›› ››
››
››
›› ›› ›› ››
BRC1D52
Limit operation (min/max): room temperature is controlled within adjustable upper and lower limits. Limit operation can be activated manually or by schedule timer Real time clock: indicates real time and day Schedule timer: - It is possible to programme a weekly schedule timer - It is possible to programme the remote control for each day of the week. Five day actions can be set as follows: · Set point: unit is switched ON and normal operation is maintained · OFF: unit is switched OFF · Limits: unit is switched ON and min / max control (cf. limit operation for more details) Home leave (frost protection): during occupants’ absence, the indoor temperature can be maintained at a certain level. This function can also switch the unit ON/OFF Different levels of disabled buttons can be selected as follows: - Level 1: all buttons are accessible - Level 2: all buttons are disabled except for: ON / OFF, set temperature up / down, fan speed, cooling / heating mode, enable / disable schedule timer, air flow direction adjustment button - Level 3: all buttons are disabled except for: ON / OFF, set temperature up / down, fan speed User friendly HRV function, thanks to the introduction of a button for ventilation mode and fan speed Constantly monitoring of the system for malfunctions in a total of 80 components Immediate display of fault location and condition Reduction of maintenance time and costs
Operation buttons: ON / OFF, timer mode start / stop, timer on / off, programmed time, temperature setting, air flow direction adjustment, operating mode selection, fan speed control, filter sign reset, inspection test / operation Display: Operating mode, Heat Recovery Ventilation (HRV) in operation, cool / heat changeover control, centralised control indication, group control indication, set temperature, air flow direction, programmed time, inspection / test operation, fan speed, clean air filter, defrost / hot start, malfunction
41
2. Centralised control systems DCS302C51
›› Centralised remote control Providing individual control of 64 groups (zones) of indoor units ›› A maximum of 64 groups (128 indoor units, max. 10 outdoor units) can be controlled ›› A maximum of 128 groups (128 indoor units, max. 10 outdoor units) can be controlled via 2 centralised remote controls in separate locations ›› Zone control ›› Group control (up and down buttons are added for group selection) ›› Control of HRV air flow direction and air flow rate ›› Expanded timer function ›› Malfunction code display ›› Maximum wiring length of 1,000m (total: 2,000m)
DCS301B51
›› Unified ON/OFF control Providing simultaneous and individual control of 16 groups of indoor units ›› A maximum of 16 groups (128 indoor units) can be controlled ›› 2 remote controls in separate locations can be used ›› Operating status indication (normal operation, alarm) ›› Centralised control indication ›› Maximum wiring length of 1,000m (total: 2,000m)
››
Schedule timer
Enabling 64 groups to be programmed ›› A maximum of 128 indoor units can be controlled ›› 8 types of weekly schedule ›› A maximum of 48 hours back-up power supply ›› Maximum wiring length of 1,000m (total: 2,000m)
42
3. Network Solutions
DS-NET adapter
F1 - F2
PC for monitoring Modem Public phone line RS485
The ideal solution for control and management up to 2,000 indoor units
P1 - P2
Modem
RS232C
Malfunction
P1 - P2
F1 - F2
Max. of 10 DS-NET adapters
Application area ›› A small commercial area of less than 40 indoor units. ›› Critical applications for centralized monitoring. System layout Allows monitoring and control of up to up to 50 stores or sites and 2,000 indoor units with just one modem and phone line. ›› Automates daily air conditioning operation in order to free users from the hassle of air conditioning operation / management. ›› The daily schedule setting allows automatic operation afterward. ›› Automates alarm (report messages) for any malfunctions / errors. Immediate report of any indoor unit breakdown to the servicing company. ›› Automatic report of breakdown / malfunction information. ›› Minimizes the inconvenience of not having air conditioning via rapid messages ››
Functions ›› Schedule setup (Daily schedule) - Start / stop ›› A / C malfunction report - Send message to monitoring system ›› Manual operation - Start / Stop, set temperature, operation mode, fan speed ›› Status monitoring - Start / Stop, set temperature, - Operation mode, room temperature, operation time, error code
43
Allows detailed and easy monitoring and operation of VRV® systems (max. 2 x 64 control groups)
Languages English, French, German, Italian, Spanish System layout ›› Up to 2 x 64 indoor units can be controlled ›› Onboard Ethernet port (web browser & e-mail) ›› Digital i / o contacts (option) ›› Touch panel (full colour LCD via icon display) Management ›› Web application & internet compatibility - Monitoring & control according to user - Remote monitoring & control of more than one building - Remote monitoring & control of more than one building via internet ›› Power Proportional Distribution (option) ›› PPD data is available on the internet ›› Easy management of electricity consumption ›› Enhanced history function Control ›› Individual control (set point, start / stop, fan speed) (max. 2 x 64 indoor units / groups) ›› Schedule control (8 schedules, 17 patterns) ›› Flexible grouping in zones ›› Yearly schedule ›› Fire emergency stop control ›› Interlocking control ›› Increased HRV monitoring and control function ›› Automatic cooling / heating changeover ›› Quick selection and full control ›› Simple navigation ›› Heating optimization ›› Temperature limit ›› Password security: 3 levels (general, administration & service)
44
third party controller (domotics, BMS, etc.)
Public line
Air Conditioning Network Service System
Ethernet
Onboard modem
PCMCIA flash memory CSV output of PPD (option) result Onboard Ethernet port
Pi-port
Links to the wattmeter when using the PPD (option) function
Malfunction
Remote monitoring / control via internet, e-mail PPD data is available on internet
[iPU]
Fire alarm
Forced OFF contact input
DIII-NET
HRV
Indoor units DIO unit
Controls drain pump, lighting etc. Monitoring of room enter/exit sign DI unit RS-232C
DIII-NET Allows monitoring/control of up to 64 units (groups)
DIII-NET PLUS adapter Indoor unit
Monitoring Visualisation via Graphical User Interface (GUI) ›› Icon colour display change function ›› Indoor units operation mode ›› Error messages via e-mail & mobile phone (option) ›› Indication filter replacement ›› Multi PC Cost performance Labour saving Easy installation Compact design: limited installation space Overall energy saving
›› ›› ›› ››
Open interface Communication to any third party controller (domotics, BMS, etc.) is possible via open interface.
››
Connectable to VRV® HRV Sky Air (via interface adapter) Split (via interface adapter)
›› ›› ›› ››
HRV
45
The ideal solution for control and management of maximum 1,024 VRV® indoor units
System layout Up to 1,024 indoor units can be controlled (by 4 iPUs) ›› Ethernet TCPIP / 10 base / T communication ›› Integrated digital contacts on the Intelligent Processing Unit (iPU) - 19 general input ports - 2 digital outputs ›› Stand alone operation of the iPU for minimum 48 hours ›› Compatible with UPS shutdown software
Control Individual control (setpoint, start / stop, fan speed) (max. 1,024 indoor units) ›› Group control (100 groups) ›› Schedule control (128 programs) ›› Fire emergency stop control (32 programs) ›› Interlocking control ›› Setpoint limitation ›› Automatic cooling heating changeover ›› Power failure / release control ›› Temperature limit (automatic start) ›› Timer extension
››
››
Management Web access function (option) Power Proportional Distribution (option) Operational history management (start/stop, malfunction, operation hours) ›› Generation of reports (graphics & tables) (daily, weekly, monthly) ›› Peak load shedding ›› Advanced tenant management ›› Sliding temperature ›› Eco mode (option)
Monitoring ›› Visualisation via a Graphical User Interface (GUI) featuring free layout ›› Operation mode of indoor & outdoor units ›› Fault indication ›› Indication filter replacement ›› Setpoint indication ›› Operation time monitoring ›› Multi PC ›› On-line help
›› ›› ›› ››
~
Intranet/Internet
Web Access
Web Access
Malfunction report by E-Mail (Via Internet)
Air Conditioning Network Service System (Optional Maintenance Service)
Ai unit
DAM602B51/52
DIII-NET DIII-NET Dio unit
46
~
Sub PC
Power supply facility
DIII-NET
ETHERNET
DIII-NET
Fire alarm
DMS502A51 BACnet Gateway (monitoring only)
Electricity Measurement
VRV System
Daikin Central Air Conditioning System
®
Local monitoring & control
HRV
LON BMS
dms504b51
Lonworks Networks Compatible Gateway
›› ›› ›› ››
DIII- NET
adapter
)ETHERNET (TCP/IP
››
LonTalk
Interface for connection to LonWorks® networks Communication via Lon protocol (twisted pair wire) 64 units connectable per DMS-IF Unlimited site size Quick and easy installation
Local Control VRV® Outdoor unit HRV
LonTalk
adapter
Remote Control LonPoint
LonPoint
BUILDING CONTROL NETWORK
DAIKIN A / C INFRASTRUCTURE
Security
Fire alarm System
Integrated control system connecting VRV® system with BMS system. PPD data is available on BMS-system Interface for BMS system Communication via BACnet protocol (connection via Ethernet)
›› ›› ››
BMS
256 units connectable per BACnet gateway Unlimited site size Easy and fast installation
DMS502A51
DIII- NET
DAM602B51 / 52 (Intelligent Manager) Control and monitoring
BACNET / ETHERNET
›› ›› ››
Local Control VRV® Outdoor unit
HRV
DAIKIN A / C INFRASTRUCTURE
Remote Control
Fire alarm
BUILDING CONTROL NETWORK
Pump
Security
Lighting
Power supply facility
Elevator
47
4. accessories Individual control systems FXFQ
DESCRIPTION Wired remote control Infrared remote control Simplified remote control Simplified remote control for hotel use
cooling only heat pump
FXZQ
BRC7F533 BRC7F532 -
FXCQ
FXKQ
FXDQ
FXDQ-N
FXSQ
FXMQ
FXUQ
FXHQ
FXAQ
FXLQ
FXNQ
BRC1D52 BRC4C64 BRC4C62 BRC2C51 BRC3A61
BRC4C66 BRC4C65 BRC2C51 BRC3A61
BRC7C529 BRC7C528 -
BRC7E66 BRC7E63 -
BRC7E619 BRC7E618 -
BRC4C64 BRC4C62 BRC2C51 BRC3A61
BRC4C64 BRC4C62 BRC2C51 BRC3A61
FXSQ
FXMQ
FXUQ
FXHQ
FXAQ
FXLQ
FXNQ
FXMQ
FXUQ
FXHQ
FXAQ
FXLQ
FXNQ
BRC7E531 BRC7E530 -
BRC7C67 BRC7C62 -
BRC4C63 BRC4C61 -
BRC4C64 BRC4C62 BRC2C51 BRC3A61
BRC4C64 BRC4C62 BRC2C51 BRC3A61
FXZQ
FXCQ
FXKQ
FXDQ
FXDQ-N
Centralised control systems DESCRIPTION
FXFQ
Centralised remote control Unified ON/OFF control Schedule timer
DCS302C51 DCS301B51 DST301B51
Others DESCRIPTION Wiring adapter Wiring adapter (hour meter) Wiring adapter for electrical appendices (1) Wiring adapter for electrical appendices (2) Remote sensor Installation box for adapter PCB Electrical box with earth terminal (3 blocks) Electrical box with earth terminal (2 blocks) Noise filter (for electromagnetic interface only) External control adapter Interface adapter for Sky Air series Connector for forced on/forced off
FXFQ
FXZQ
EKRP1C11*1 KRP2A526*1 KRP4AA53*1 KRCS01-4 KRP1H98 KJB212AA -
FXCQ
KRP1B57*1 EKRP1B2 KRP2A526*1 KRP2A516*1 KRP4A536*1 KRP4A516*1
FXKQ
FXDQ
FXDQ-N
KRP1B61 KRP2A61 KRP4A51
KRP1B61 EKRP1B2*2 KRP2A516 KRP4A516
KRP1B56 KRP2A53 KRP4A54
FXSQ
KRP1B61 KRP4A53 KRP1B3 KRP1B61 KRP1B61 EKRP1B2 KRP2A516 KRP2A61 KRP2A62* KRP2A51 KRP2A51 KRP2A51 KRP4A516 KRP4A51 KRP4A52* KRP4A51 KRP4A51 KRP4A51 KRCS01-1 KRP1BA101 KRP1B96*3/4 KRP1BA101 KRP1B97 KRP1C93*3 KRP4A93*3/4 KJB311A KJB212A KEK26-1A DTA104A52 DTA104A51*1 DTA104A61 DTA104A51 DTA104A53 DTA104A51 DTA104A61 DTA104A62 DTA104A51 DTA104A61 DTA104A61 DTA102A52 EKRORO -
Notes: *1: Installation box is required *2: Fixing box is KRP1A90 *3: Up to 2 adapters can be fixed per installation box *4: Only 1 installation box can be installed per indoor unit
DESCRIPTION DS-net adapter Software
DESCRIPTION Intelligent Touch Controller Software Hardware Installation box Touch-Pen Interface adapters
Digital input Digital input/output
48
REFERENCE
COMMENTS
DTA113B51 DPC001B1-B51
4 units can be connected per adapter, 40 units when 10 adapters are connected Monitoring panel software
REFERENCE
COMMENTS
DCS601C51 DCS002C51 DCS004A51 DCS601A52 KJB411A 1264009 KRP928A2S DTA102A52 DTA112B51 DEC101A51 DEC102A51
2x64 units can be connected Power Proportional Distribution (PPD) software E-mail / Web software DIII NET-Plus adapter For wall mounted installation Spare part n째 of Touch-Pen for Intelligent Touch Controller For connection to Split units For connection to R-22 / R-407C Sky Air units For connection to R-410A Sky Air units Input contacts: 16 points Input contacts: 8 points; output contacts: 4 points
DESCRIPTION
REFERENCE
COMMENTS
Intelligent Processing unit
DAM602B51 DAM602B52 IM3.XX KRP928A2S DTA102A52 dta112b51 DAM101A51 DEC10151* DEC10251* DAM002A51 DAM003A51 DAM004A51
256 indoor units per IPU 128 indoor units per IPU Up to 1,024 indoor units For connection to Split units For connection to R-407C/R-22 Sky Air units For connection to R-410A Sky Air units Outdoor temperature sensor Input contacts: 16 points Input contacts: 8 points; output contacts: 4 points
Software Interface adapters
DIII Ai Digital input Digital input / output Power Proportional Distribution ECO Mode Web Acces Function
DESCRIPTION LonWorks networks compatible Gateway Interface adapters ®
DESCRIPTION BACnet Gateway DIII board Digital input/output Interface adapters
REFERENCE
COMMENTS
DMS504B51 KRP928A2S DTA102A52 dta112b51
Up to 64 units can be connected per DMS-IF For connection to Split units For connection to R-407C/R-22 Sky Air units For connection to R-410A Sky Air units
REFERENCE
COMMENTS
DMS502B51 DAM411B51 DAM412B51 KRP928A2S DTA102A52 dta112b51
64 units per Gateway Extension of 3 x DIII lines (3 x 64) indoor units For forced shutdown For connection to Split units For connection to R-407C/R-22 Sky Air units For connection to R-410A Sky Air units
BMS: Building Management system
Contact / analog signal
DESCRIPTION Parallel interface - Basic unit Temperature measurement units Temperature setting units Unification adapter for computerised control Wiring adapter for electrical appendices (1)
Wiring adapter for electrical appendices (2) External control adapter for outdoor unit DIII-net expander adapter Mounting kit
REFERENCE
COMMENTS
DPF201A51 DPF201A52 DPF201A53 DCS302A52 KRP2A51 KRP2A52 KRP4A51-53 DTA104A51 DTA104A52 DTA109A51
enables ON/OFF command, operation and display of malfunction can be used in combination with up to 4 units. enables temperature measurement output for 4 groups; 0~5VDC.» enables temperature setting input for 16 groups; 0~5VDC.» used for combining of air conditioning control computer and central remote controller (ON/OFF, display) simultaneously controls air conditioning control computer and up to 64 groups of indoor units.
KRP4A92
to control the group of indoor units collectively, which are connected by the transmission wiring of remote controller. cooling/heating mode change over, demand control and low noise control are available between the plural outdoor units. a maximum of 10 outdoors or 128 indoors can be connected to 1 DTA109A51 a maximum of 8 DTA109A51 can be connected to DIII-net for easy installation of the DTA109A51
49
Notes
50
Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product.
ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment.
The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.
Daikin units comply with the European regulations that guarantee the safety of the product. Daikin products are distributed by:
VRV® products are not within the scope of the Eurovent certification programme.
Naamloze Vennootschap Zandvoordestraat 300 B-8400 Oostende, Belgium www.daikin.eu BTW: BE 0412 120 336 RPR Oostende
FSC
EPCEN08-201 • XXX • 02/08 • Copyright © Daikin The present publication supersedes EPCEN07-201. Printed on non-chlorinated paper. Prepared by La Movida, Belgium Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende
Daikin’s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste.