We measure it.

Everything under control: With testo SaverisTM, measurement data are under control everywhere.


Saveris

testo SaverisTM: Easy, safe and efficient measurement data monitoring The data monitoring system testo Saveris measures the temperature and humidity values of sensitive goods and products in ambient as well as in process conditions. The easy-to-use measurement system delivers safety and savings in time and costs thanks to automated measurement data recording. The transfer of the data takes place by wireless and/or Ethernet connection to a base station. This documents and monitors all measurement data. If limit values are exceeded, a whole range of different alarm options, such as SMS/e-mail alarm or alarm relay is available. Remote alarms can even be given when the system is not connected to a running PC.

2


We measure it.

In addition to this, transmitters of all measurement parameters with standard current/voltage interfaces can be integrated into the Saveris system. The integration of Testo transmitters as well as those of other manufacturers is possible. All recorded data are stored centrally in a software. At the same time, the Saveris software allows the extensive analysis and evaluation of all data gathered.

3


Saveris

testo Saveris™ system overview Data monitoring for uninterrupted checks testo SaverisTM wireless probe

testo SaverisTM router

testo SaverisTM converter

Probe versions with internal and external temperature and humidity sensors allow the adaptation to every application. The radio probes are available with or without a display as an option. Current measurement data, the battery status and the quality of the radio link are shown on the display.

The radio link can be improved or lengthened in poor structural conditions by using a router. Several routers can of course be used in the testo Saveris system. At the same time, the serial switching of up to 3 routers V 2.0 offers highest flexibility in the wireless range.

Through the connection of a converter to an Ethernet jack, the signal of a radio probe can be converted into an Ethernet signal. This combines the flexible connection of the radio probe with the use of the existing Ethernet even over long transmission paths.

testo SaverisTM converter V 2.0

testo SaverisTM router V 2.0

Ethernet

testo SaverisTM wireless probe

testo SaverisTM analog coupler (Ethernet)

Humidity transmitters

testo SaverisTM analog coupler (wireless)

testo SaverisTM analog coupler

Humidity transmitters testo 6651/6681/6351/6381

The two versions of the analog coupler (wireless / Ethernet) allow the inclusion of other measurement parameters into the testo Saveris monitoring system, by integrating all measurement transmitters with standarized current/voltage interfaces, e. g. 4 to 20 mA or 0 to 10 V.

Thanks to the integration of the humidity and differential pressure transmitters, measurement data monitoring is possible parallel to the control. This provides the solution for highest accuracy as well as for special applications (high humidity, trace humidity etc.) in compressed air, drying and air conditioning technology and in cleanroom applications. Find out more at www.testo.com/transmitter

4


We measure it.

testo SaverisTM Base

testo SaverisTM software

The base is the heart of testo Saveris and can save 40,000 readings per measurement channel independently of the PC. This corresponds to around one year of memory capacity at a measuring rate of 15 minutes. The system data and alarms are visible via the display of the Saveris base.

The testo Saveris software offers simple operation and an intuitive user interface. The Saveris software is available in three different versions: as the basic version SBE (Small Business Edition), the PROF (Professional) software version with diverse additional options, or as the CFR version. The CFR software fulfils the requirements of the FDA’s 21 CFR Part 11 and is thus validatable.

Ethernet

USB or Ethernet

testo SaverisTMBase

Ethernet

testo SaverisTM Ethernet probe

testo SaverisTM Software

testo SaverisTM Ethernet probe In addition to the radio probes, probes can be used that are directly connected to the Ethernet. The existing LAN infrastructure can be used through this. This allows the data transfer from the probe to the base, even over long distances.

5


Saveris

Overview of testo SaverisTM application areas

Monitoring the foodstuff cooling chain Compliance with predefined temperature values is a decisive factor for quality in food production and is important for complying with legal hygiene standards. testo Saveris automates not only the monitoring of the ambient and production temperatures during production and storage, but also of defined temperature limit values during transport. The installation of wireless probes in delivery vehicles makes the complicated wiring of the driver’s cabin unnecessary. Alarms are issued whenever the limit values are exceeded. The measurement data and any occurring alarms are saved centrally in a database and are accessible at any time. testo Saveris conforms to the EN 12830 standard.

6


We measure it.

Monitoring in production, quality assurance and storage in industry In industry, a number of quality data must be recorded and monitored in the production, quality assurance and storage of products. testo Saveris automates the documentation of these data and alarms when limit values are exceeded. Products and processes are thus guaranteed at a high level of quality. testo Saveris is ideal for use in the monitoring and documentation of ambient and temperature data in production areas, storerooms, refrigerators and climate cabinets. The most varied applications are optimally covered by testo Saveris radio probes and/or Ethernet probes.

7


Saveris

Overview of testo SaverisTM application areas

Monitoring of processes in the pharmaceutical industry In the pharmaceutical industry, high demands are placed on the recording and monitoring of quality parameters. Constant documentation and monitoring during the production and storage of temperature-sensitive products such as medicines, blood products or cell cultures has long been considered an absolute “must�. testo Saveris automates the central documentation of measurement data as well as the safe monitoring of refrigerated and deep-freeze rooms, incubators and climate cabinets. The comprehensive alarm management allows fast alarming if limit values are violated. Thanks to a combination of wireless and/or Ethernet probes, the system is optimum for many different applications in the pharmaceutical industry. It goes without saying that the data monitoring system testo Saveris meets the requirements of 21 CFR Part 11.

8


We measure it.

Monitoring of the building climate When monitoring the building climate, stable ambient conditions are especially necessary in museums and archives in order to protect sensitive and valuable objects. testo Saveris automates the central recording of all climate data. By issuing alarms when limit values are exceeded, testo Saveris protects valuable inventory from undesired temperature or humidity influences at all times. The radio probe can be flexibly attached to locations without the effort of routing cables.

Monitoring of processes in research and development, laboratories and hospitals Research and development areas as well as laboratories and hospitals are responsible for the recording of ambient and process data in order to monitor sensitive products or machines. testo Saveris carries out the central documentation and monitoring of the measurement series. testo Saveris thus guarantees the simple and secure monitoring of climate and process data in air conditioning chambers, refrigerators, drying chambers, test benches or blood banks. At the same time, the Saveris software allows the extensive analysis and evaluation of all measurement data gathered.

9


Saveris

testo Saveris™ software

1

Installation made easy · Connect Saveris base to mains. The probes can now be logged on at the base: They are switched on in series and automatically identified by the base. · The Saveris base is connected to the PC via USB or Ethernet. The software is installed on the PC with help from the installation wizard. · The system is ready for configuration: Probe name, limit values, measuring cycles and alarms can be adapted to the individual measuring tasks.

2

Clear and always up-to-date · The measurement data can always be shown as a graphic or table. · Various probes can be compiled into groups. Logical units by measurement task are thus formed. · The measurement data view over days, weeks or months is freely definable. The integrated calendar offers practical assistance here.

3 Daily report Cold storage house zone: Hourly mean values on 03.08.2007 Time

°C freezer 1

%RH cold room 1 °C refrigerator

°C drinks

°C freezer 2

°C freezer 3

°C freezer 4

Automated documentation · Form and time of the reporting are predefined once. · The creation and saving of reports as a PDF file now takes place automatically in accordance with the set conditions. The files are therefore ready to be printed at any time.

Total maximum value Total mean value Total minimum value

10


We measure it.

Small Business Edition (SBE), Professional (PROF) and CFR version

4

Now more flexible with Professional software The PROF (Professional) software version offers interesting additional functions beyond the attractive standard functions of the basic version SBE, e.g.:

21 °C 48 %RH

· Client-server concept: The measurement data can be monitored by various PCs integrated into the network. Photographs of machines or rooms can be saved as a picture. The · respective measurement values are shown directly at the position of the probe in the room or at the machine in these. The link between the location and the measurement value is thus very easily visualized (fig. 4). A · comprehensive alarm management offers the option of alarming more than two people at the same time or in succession. Depending on the day of the week or the time, it is possible to choose whether the alarm is given as an e-mail and/or an SMS.

26 °C 38 %RH

41 °C 22 %RH

5

Validatable CFR software The CFR software fulfils the requirements of the FDA’s 21 CFR Part 11 and is thus validatable.

Overview of software features SBE

PROF

CFR

• • • •

• • • • • • • • •

• • • • • • • • • • • • •

Diagrams / tables / Alarm overview / PDF reports Calendar management Presentation of probe groups Alarm dispatch (e-mail, SMS, relay) Comprehensive alarm management Automated update of measurement data (“Online mode”) Measurement data on background photo of measruement sites Integration in network (client-server) Allocation of access rights for stationary and mobile probe groups 21 CFR Part 11 compliant (validatable) Electronic signature Audit trail for tracing user activity Allocation of access rights on 3 user levels

SBE software, incl. USB connecting cable base-PC Order no. 0572 0180 PROF software, incl. USB connecting cable base-PC Order no. 0572 0181 CFR software, incl. Ethernet connecting cable base-PC Order no. 0572 0182

11


Saveris

testo Saveris™ Base

The base is the heart of testo Saveris and can save 40,000 readings per measurement channel independently of the PC. The system data and alarms are visible via the display of the Saveris base.

Display for showing alarms and system data Large data memory Issue of alarms via LED/relay SMS alarm (optional) Emergency battery integrated Up to 150 probes can be connected

Connection option via USB or Ethernet

Technical data

12

Ordering data

Rech. batt.

Li-ion battery (for data back-up and for emergency SMS with failure of the power supply)

Oper. temp. Storage temp. Display Interfaces Connectable radio probe

-10 to +50 °C -40 to +60 °C graphical display, 4 control keys USB, radio, Ethernet max. 15 probes can be directly connected via radio interface, max. 150 total via radio / Router / Converter / Ethernet, max. 450 channels

Alarm relay GSM module

max. 1 A, max. 30 W, max. 60/25 V DC/AC, NC or NO contact 850/900/1800/1900 MHz not valid for Japan and South Korea

Set up Firmware Version

Table base and wall bracket included 2.X

Saveris base, radio frequency 868 MHz 2.4 GHz

40,000 values per channel (total max. 18.000.000 values) 225 x 150 x 49 mm approx. 1510 g IP42 Die-cast zinc/plastic 2.4 GHz 6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals, power consumption 4 W

2.4 GHz

Memory Dimensions Weight Protection class Housing material Radio frequency Power supply (absolutely necessary)

Order no. 0572 0220

Saveris base, radio frequency 868 MHz, GSM module integrated (for SMS alarm) Order no. 0572 0221

No mains units or antennas with magnetic base are contained in this ordering data.

Note on the radio frequencies

2.4 GHz:

non EU countries


We measure it.

testo Saveris™ components: Router und Converter

The radio link can be improved or lengthened in poor structural conditions by using a router. Several routers can of course be used in the testo Saveris system. At the same time, the serial switching of up to 3 routers V 2.0 offers highest flexibility in the wireless range. Through the connection of a converter to an Ethernet jack, the signal of a radio probe can be converted into an Ethernet signal. This combines the flexible connection of the radio probe with the use of the existing Ethernet even over long transmission paths.

Radio

Radio

Radio

Radio

Ethernet

Use

Ethernet

Saveris Router V 1.0

Saveris Router V 2.0

Saveris Converter V 1.0

Saveris Converter V 2.0

· for Saveris Base

· for Saveris Base

· for Saveris Base Firmware Version V 1.X · nonly for wireless probes

· for all Saveris Base Firmware versions · only for wireless probes with

Firmware Version V 1.X

Firmware Version V 2.X

Firmware Version 1.x

Dimensions Weight Power supply

approx. 85 x 100 x 38 mm approx. 180 g 6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals, power consumption

Oper. temp. Storage temp. Housing material Protection class Interfaces Connectable radio probe Router cascading Wall holder

approx. 190 g 6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals, PoE, power consumption

-20 to +50 °C -40 to +60 °C Plastic IP54 Radio max. 5

Radio, Ethernet max. 15

No

Yes

included

Saveris router, V 1.0,868 MHz, radio transmission medium

Saveris router, V 2.0,868 MHz, radio transmission medium

Saveris Cverter V 1.0, 868 MHz, converts the radio transmission medium to Ethernet

Saveris Cverter V 2.0, 868 MHz, converts the radio transmission medium to Ethernet

Order no. 0572 0159

Order no. 0572 0259

Order no. 0572 0158

Order no. 0572 0258

2.4 GHz

Versions

Firmware Version V 2.X

No mains units are contained in this ordering data.

13


Saveris

testo Saveris™ components: Radio probe Probe versions with internal and external temperature sensors and with humidity sensors allow the adaptation to every application. The radio probes are available with or without a display as an option. Current measurement data, the battery status and the quality of the radio link are shown on the display.

°C / °F

External probe

Internal sensor

Radio

Pt 100

internal

internal

external

external

external

81 mm

TC 81 mm

TC 81 mm

NTC 81 mm

NTC

Saveris T1

Saveris T2

Saveris T3

Radio probe with internal NTC

Radio probe with external probe connection and internal NTC, door contact

2-channel radio probe with 2 external TC Radio probe with 1 external Pt100 probe probe connections (TC characteristics can connection be selected)

Probe type

NTC

NTC

Measuring range Accuracy

-35 to +50 °C ± 0.4 °C (-25 to +50 °C) ±0.8 °C (remaining meas. range)

-35 to +50 °C ± 0.4 °C (-25 to +50 °C) ±0.8 °C (remaining meas. range)

Resolution Probe type Measuring range (instrument)

0.1 °C

0.1 °C NTC -50 to +150 °C

– –

Accuracy (instrument)

Resolution (instrument) Connection

– TC Type J

-195 to +1350 °C -100 to +750 °C

TC type T

TC type S

-200 to +400 °C

0 to +1760 °C

– Pt100 -200 to +600 °C

± 0.2 °C (-25 to +70 °C) ±0.4 °C (remaining meas. range)

±0.5 °C or 0.5% of reading)

at +25 °C ± 0.1 °C (0 to +60 °C) ±0.2 °C (-100 to +200 °C) ±0.5 °C (remaining meas. range)

– –

0.1 °C NTC via Mini DIN socket, Door contact connection cable included in delivery (1.80 m)

0.1 °C / TC Type S 1 °C 2 TCs via TC socket, max. difference in potential 2 V

0.01 °C 1 Pt100 via mini-DIN socket

80 x 85 x 38 mm approx. 240 g

Battery life (Type: 4 x AA) Housing material Protection class Radio frequency Meas. cycle Memory Conformity with standards Oper. temp. Storage temp. Display (optional) Transmission distance Wall holder

Battery life 3 years at +25 °C; 3 years with Energizer L91 Photo lithium batteries for freezer applications Plastic IP68

IP54 2.4 GHz Standard 15 min, can be set from 1 min up to 24 h 6.000 readings per channel

DIN EN 12830 -35 to +50 °C

IP68

– -20 to +50 °C -40 to +55 °C (incl. batteries) 2-line LCD; 7 segments with symbols approx. 100 m free field at a frequency of 2.4 GHz included

Versions Version without display Saveris T1 Order no. 0572 1250 *

2.4 GHz

Dimensions (housing): Weight

Version with display

TC Type K

Saveris Pt

Saveris T1 D Order no. 0572 1260 *

Saveris T2 Order no. 0572 1251 *

Saveris T3 Order no. 0572 9252 *

Saveris Pt Order no. 0572 7251 *

Saveris T2 D Order no. 0572 1261 *

Saveris T3 D Order no. 0572 9262 *

Saveris Pt D Order no. 0572 7261 *

The AA alkali manganese mignon batteries (0515 0414) are contained in this ordering data (excepting analog coupler). Saveris probes are delivered with a calibration protocol of the works adjustment data. Calibration certificates must be ordered separately. * The Saveris Converter V 2.0 (order no. 0572 0258) is required for integration of Saveris wireless probes into systems with Base firmware V 1.X For more information please contact your Testo partner.

14


We measure it.

testo Saveris™ components: Radio probe

mA and V

°C / °F and %RH

Radio

% RH NTC

% RH NTC

% RH NTC

external

internal

external

Internal sensor

internal

Saveris H2 D

Saveris H3

Saveris H4 D

Saveris U1

Humidity radio probe

Radio probe with 1 external humidity probe connection

Radio probe with current/voltage input

Measuring range

External probe

V

Humidity radio probe

Probe type

NTC

Humidity sensor

-20 to +50 °C

0 - 100 %RH

– Accuracy

± 0.5 °C

±3 %RH at +25 °C ±0,03 %RH/K ±1 Digit

Resolution – NTC Humidity sensor Probe type Meas. range (instrument) -20 to +50 °C 0 to +100 %RH 2) Accuracy (instrument)

mA

± 0.5 °C

0.1 °C

0.1 % / 0.1 °Ctd – –

NTC -20 to +70 ± 0.2 °C

to 90 %RH: ±2 %RH at +25° C > 90 %RH: ±3 %RH at +25° C ±0,03 %RH/K ± 1 Digit

1 channel: Current/voltage input

2-wire: 4 ... 20 mA 4-wire: 0/4 ... 20 mA, 0 to 1/5/10 V, load: max. 160 Ω at 24 V DC

Current ±0.03 mA / 0.75 μA Voltage 0 to 1 V ±1.5 mV/39 μV Voltage 0 to 5 V ±7.5 mV / 0.17 mV Voltage 0 to 10 V ±15 mV / 0,34 mV ±0.02% of m.v./K deviating from nominal temperature 22 °C – –

– Humidity sensor 0 to +100 %RH 2)

see probes –

0,1%/0.1 °Ctd Resolution (instrument) 0.1 °C Connection fixed stump probe

– –

0,1%/0.1 °Ctd 0.1 °C 1 x external humidity probe Mini DIN socket

– 2/4-wire current/voltage input Service interface Mini DIN for adjustment

Dimensions (housing): Weight Battery life (Type: 4 x AA) Housing material Protection class Radio frequency Meas. cycle Memory Oper. temp. Storage temp. Display (optional) Transmission distance Wall holder

80 x 85 x 38 mm 85 x 100 x 38 mm approx. 245 g approx. 256 g Batery life 3 years at +25 °C; 3 years with Energizer L91 Photo lithium batteries for freezer applications Plastic

2.4 GHz

IP42

IP54

IP54

2.4 GHz Standard 15 min, can be set from 1 min up to 24 h 6.000 readings per channel -20 to +50 °C -40 to +55 °C (incl. batteries) 2-line LCD; 7 segments with symbols approx. 100 m free field at a frequency of 2.4 GHz included

Versions Version without display Version with display

approx. 85 x 100 x 38 mm approx. 240 g Supply: Mains unit 6.3 V DC, 20 to 30 V DC max. 25 V AC

Saveris H3 Order no. 0572 6250 * Saveris H2 D Order no. 0572 6262 *

Saveris H3 D Order no. 0572 6260 *

(no display)

Saveris U1 Order no. 0572 3250 * Saveris H4 D Order no. 0572 6264 *

The AA alkali manganese mignon batteries (0515 0414) are contained in this ordering data (excepting analog coupler). Saveris probes are delivered with a calibration protocol of the works adjustment data. Calibration certificates must be ordered separately. 1) Not

for condensing atmosphere. For continuous applications in high humidity (>80 %RH at ≤30 °C for >12 h, >60 %RH at >30 °C for >12h), please contact us via www.testo.com.

* The Saveris Converter V 2.0 (order no. 0572 0218) is required for integration of Saveris wireless probes into systems with Base firmware V 1.X For more information please contact your Testo partner.

15


Saveris

testo Saveris™ components: Ethernet probes The existing LAN infrastructure can be used through the Ethernet probe. This allows the data transfer from the probe to the base, even over long distances. Ethernet probes have a display.

°C NTC

TC

Pt 100

external

external

external

External probe

Ethernet

Probe type Measuring range (instrument) Accuracy (instrument)

Resolution (instrument) Connection

Dimensions (housing): Weight Supply Buffer battery Housing material Protection class Meas. cycle Memory Oper. temp. Storage temp. Power consumption Display (optional) Wall holder Versions

Saveris T1 E

Saveris T4 E

Saveris Pt E

Ethernet probe with external NTC probe connection

4-channel Ethernet probe with 4 external TC probe connections

Ethernet probe with external Pt100 probe connection

NTC -50 to +150 °C

TC Type K

TC Type J

-195 to +1350 °C

-100 to +750 °C

TC type T

TC type S

-200 to +400 °C

0 to +1760 °C

Pt100 -200 to +600 °C

± 0.2 °C (-25 to +70 °C) ±0.4 °C (remaining meas. range)

±0.5 °C or 0.5% of reading)

at +25 °C ± 0.1 °C (0 to +60 °C) ±0.2 °C (-100 to +200 °C) ±0.5 °C (remaining meas. range)

0.1 °C 1 NTC via mini-DIN socket

0.1 °C / TC Type S 1 °C 4 TCs via TC socket max. potential difference 50 V

0.01 °C 1 Pt100 via mini-DIN socket

Saveris T1 E With display Order no. 0572 1191

Mini-DIN service interface for adjustment is accessible externally approx. 85 x 100 x 38 mm approx. 220 g 6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals, PoE Li-ion Plastic IP54 2 sec to 24 h 6.000 readings per channel -20 to +60 °C -40 to +60 °C PoE Class 0 (typically ≤ 3 W) 2-line LCD; 7 segments with symbols included Saveris T4 E Saveris Pt E With display With display Order no. 0572 9194

Order no. 0572 7191

Saveris probes are delivered with a calibration protocol of the works adjustment data. Calibration certificates must be ordered separately. Mains units are not included in delivery.

16


We measure it.

testo Saveris™ components: Ethernet probes

mA and V

°C / °F and %RH % RH NTC

% RH NTC

% RH NTC

external

external

external

mA

V

internal

External probe

Internal sensor

Ethernet Saveris H1 E

Saveris H2 E

Saveris H4 E

Saveris U1 E

Humidity Ethernet probe 1%

Humidity Ethernet probe 2 %

Ethernet probe with external humidity probe connection

Radio probe with current/voltage input

Probe type

1 channel: Current/voltage input

Measuring range

2-wire: 4 ... 20 mA 4-wire: 0/4 ... 20 mA, 0 to 1/5/10V, load: max. 160 Ω at 24 V DC

Accuracy

Current ±0.03 mA / 0.75 μA Voltage 0 to 1 V ±1.5 mV / 39 μV Voltage 0 to 5 V ±7.5 mV / 0.17 mV Voltage 0 to 10 V ±15 mV / 0.34 mV ±0.02% of m.v./K deviating from nominal temperature 22 °C

Probe type Measuring range (instrument) Accuracy (instrument)

NTC -20 to +70 °C

Humidity sensor 0 to 100 %RH1)

± 0.2 °C (0 to +30 °C) to 90 %RH: ±(1 %RH +0.7 % of m.v.) ±0.5 °C (remaining at +25 °C meas. range) > 90 %RH: ±(1.4 %RH +0.7 % of m.v.) at +25 °C

Resolution (instrument) 0.1 °C Connection

0.1% / 0.1 °Ctd

NTC -20 to +70 °C

Humidity sensor 0 to 100 %RH1)

NTC -20 to +70 °C1)

Humidity sensor 0 to 100 %RH1)

±0.5 °C

to 90 %RH: ±2 %rH at +25 °C > 90 %RH: ±3 %rF at +25 °C ± 0,03 %RH/K ± 1 Digit

± 0.2 °C

see external probes

0.1% / 0.1 °Ctd

0.1 °C 0.1%/0.1 °Ctd 1 x external humidity probe Mini DIN socket

0.1 °C

– –

– 1 x 2/4-wire current/voltage input

Mini-DIN service interface for adjustment is accessible externally approx. 85 x 100 x 38 mm approx. 254 g approx. 230 g 6.3 V DC mains unit; alternatively via 24 V AC/DC plug-in/screw terminals, PoE Li-ion

Dimensions (housing): Weight Supply Buffer battery Housing material Protection class Meas. cycle Memory Oper. temp. Storage temp. Power consumption Display (optional) Wall holder Versions

approx. 240 g

Plastic IP54 2 sec to 24 h 6.000 readings per channel -20 to +60 °C -40 to +60 °C PoE Class 0 (typically ≤ 3 W) 2-line LCD; 7 segments with symbols included

no display

Saveris H1 E With display

Saveris H2 E With display

Saveris H4 E With display

Saveris U1 E no display

Order no. 0572 6191

Order no. 0572 6192

Order no. 0572 6194

Order no. 0572 3190

Saveris probes are delivered with a calibration protocol of the works adjustment data. Calibration certificates must be ordered separately. Mains units are not included in delivery. 1)Not for condensing atmosphere. For continuous applications in high humidity (>80 %RH at ≤30 °C for >12 h, >60 %RH at >30 °C for >12h), please contact us via www.testo.com. Sintered caps for Saveris H1 E, H2 E and H2 D Ethernet probes

Order no.

Metal protective cap, Ø 12 mm for humidity probes, for measurement at flow velocities les than 10 m/s

0554 0755

Stainless steel sintered filter, pore size 100 μm, sensor protection for dusty atmospheres or higher flow velocities, for measurement in high flow velocities or contaminated air

0554 0647

Cap with wire fabric filter, Ø 12 mm

0554 0757

Sintered PTFE filter, Ø 12 mm, for aggressive media, high-humidity applications (long-term measurements), high flow velocities)

0554 0756

Testo saline pots for monitoring and humidity adjustment of humidity probes, 11.3% RH and 75.3% RH, incl. adapter for humidity probe, quick check or calibration of humidity probe

0554 0660

17


Saveris

testo Saveris™ accessories: External temperature probes

Pt 100

Plug-in probes

Illustration

Robust, Pt100 stainless steel food probe (IP65)

125 mm

15 mm

Meas. range

Accuracy

t99

Order no.

-50 to +400 °C

Class A (-50 to +300 °C), Class B (rem. meas. range)

10 sec

0609 2272

-50 to +180 °C

Class A

10 sec

0572 7001

Ø 4 mm Ø 3 mm

Connection: Fixed cable extended Penetration probe Pt100 with ribbon cable, cable length 2 m, IP 54

60 mm

30 mm

Ø 5 mm

Ø 3.6 mm

0554 0213

Connection cable for unlimited Pt100 stationary probes (4-wire technology), Cable length: 3 m, possible max. cable length: 20 m

TC

Plug-in probes

Illustration 40 mm

Stationary probe with stainless steel sheath, TC Type K

Meas. range

Accuracy

t99

Order no.

-50 to +205 °C

Class 2*

20 sec

0628 7533

-40 to + 220 °C Class 1

7 sec

0572 9001

-50 to +170 °C

Class 2*

150 sec

0602 4792

-50 to +400 °C

Class 2*

-60 to +130 °C

Class 2*

5 sec

0602 4592

-50 to +120 °C

Class 1*

90 sec

0628 0020

-50 to +400 °C

Class 2*

5 sec

0602 0644

-50 to +400 °C

Class 2*

5 sec

0602 0645

-50 to +250 °C

Class 2*

5 sec

0602 0646

-200 to +1000 °C

Class 1*

5 sec

0602 5792

-200 to +1300 °C

Class 1*

4 sec

0602 5693

Ø 6 mm

Connection: Fixed cable 1.9 m Penetration probe TC with ribbon cable, Type K, cable length 2 m, IP 54 35 mm Magnetic probe, adhesive power approx. 20 N, with magnets, for measurements on metal surfaces, TC type K Fixed cable extended

60 mm

30 mm

Ø 5 mm

Ø 3.6 mm

Ø 20 mm

75 mm Magnetic probe, adhesive power approx. 10 N, with magnets, for higher temperatures, for measurements on metal surfaces, TC type K Connection: Fixed cable 1.6 m

Pipe wrap probe for pipe diameters from 5 - 65 mm, with exchangeable measuring head, measuring range briefly up to +280°C, TC type K

Connection: Fixed cable 1.5 m

Thermocouple with TC plug, flexible, length 800 mm, fibreglass, TC Type K

Ø 1.5 mm

Thermocouple with TC plug, flexible, length 1500 mm, fibreglass, TC Type K

Ø 1.5 mm

Thermocouple with TC plug, flexible, length 1500 mm, fibreglass, TC Type K

Ø 1.5 mm

800 mm

1500 mm

1500 mm

Immersion measuring tip, flexible, TC type K

500 mm Ø 1.5 mm

Immersion measuring tip, flexible, for measurements in air/exhaust gases (not suitable for measurements in smelters

1000 mm Ø 3 mm

The specified accuracy class of the Saveris radio and Ethernet probe is achieved using these external probes.

18

0602 4892

Connection: Fixed cable 1.2 m 395 mm 20 mm

Pipe wrap probe with Velcro tape, for measuring temperatures on pipes with diameters up to max. 120 mm, Tmax +120°C, TC type K

Ø 21 mm

*Acc. to norm EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).


We measure it.

testo Saveris™ accessories: External temperature and humidity probes

NTC

Plug-in probes

Illustration

Meas. range

Stump probe, IP 54

35 mm

40 mm

t99

Order no.

15 sec

0628 7510

-20 to +70

± 0.2 °C (-20 to +40 °C) ±0.4 °C (+40.1 to +70 °C)

-30 to +90 °C

± 0.2 °C (0 to +70 °C) 190 ±0.5 °C (remaining meas. range)sec

0628 7503*

-35 to +80 °C

± 0.2 °C (-25 to +74.9 °C) 5 ±0.4 °C (remaining meas. range)sec

0610 1725*

-35 to +80 °C

5 ± 0.2 °C (-25 to +74.9 °C) ±0.4 °C (remaining meas. range)sec

0628 0006*

-40 to +125 °C

±0.5 % of reading (+100 to +125 °C) 8 ±0.2 °C (-25 to +80 °C) sec ±0.4 °C (remaining meas. range)

0572 1001

-50 to +80 °C

± 0.2 °C (0 to +70 °C)

0628 7507

Ø 3 mm

Stationary probe with aluminium sleeve, IP 65

Probe accuracy

Ø 6 mm

Connection: Fixed cable; Cable length: 2.4 m Accurate immersion/penetration probe, cable length 6 m, IP 67

40 mm Ø 3 mm

Ø 3 mm

Connection: Fixed cable; Cable length: 6 m Accurate immersion/penetration probe, cable length 1,5 m, IP 67

40 mm Ø 3 mm

Ø 3 mm

Connection: Fixed cable; Cable length: 1.5 m Penetration probe NTC with ribbon cable, cable length 2 m, IP 54

60 mm

30 mm

Ø 5 mm

Ø 3.6 mm

Wall surface temperature probe, e. g. for proof of structural damage in buildings

20 sec

Connection: Fixed cable; Cable length: 3 m Stainless steel NTC food probe (IP65) with PU line

125 mm

15 mm

Ø 4 mm

Ø 3 mm

-50 to +150 °C2) ±0.5 % of reading (+100 to +150 °C) 8 ±0.2 °C (-25 to +74.9 °C) sec ±0.4 °C (remaining meas. range)

Connection: Fixed cable; Cable length: 1.6 m 300 mm 30 mm

Pipe wrap probe with Velcro tape for pipe diameters of up to max. 75 mm, Tmax. +75°C, NTC

0613 2211*

0613 4611

-50 to +70

± 0.2 °C (-25 to +70 °C) ±0.4 °C (-50 to -25.1 °C)

Meas. range

Accuracy

Order no.

±0,3 °C ±2 %RH at +25 °C (2 ... 98 %RH) ±0.03 %rF ±1 Digit ±0,3 °C ±2 %RH at +25 °C (2 ... 98 %RH) ±0.08 %rF ±1 Digit

0572 6172

Connection: Fixed cable; Cable length: 1.5 m

% RH

Plug-in probes

Illustration

Humidity / temperature probe 12 mm Ø 12 mm

Humidity / temperature probe 4 mm

Ø 4 mm

The specified accuracy class of the Saveris radio and Ethernet probe is achieved using these external probes.

-20 to +70 °C, 0 to +100 %RH 0 to +40 °C, 0 to +100 %RH

0572 6174

*Probe tested according to EN 12830 for suitability for the areas of transport and storage 2) Long-term measuring range to +125 °C, briefly to +150 °C or +140 °C (2 minutes)

19


Saveris

testo Saveris™: Accessories

Power supply Spare batteries for radio probes (4 x AA alkali manganese mignon batteries)

0515 0572

International mains unit 100-240 V AC / 6.3 V DC; for mains operation or battery charging in intrument

0554 1096

Mains unit (desktop) 110 to 240 VAC / 24 VDC (350 mA) Miscellaneous 1

2

3

Magnetic foot aerial (dual band) with 3 m cable, for Base with GSM module (not suitable for USA, Canada, Chile, Argentina, Mexico) Antenna with magnetic foot (quad band) for Base with GSM module Alarm module (optical + audible), connectable to Base alarm relay, Ø 70 x 164 mm, 24 V AC/DC / 320 mA, permanent light: rot, permanent tone: buzzer approx. 2.4 kHz (mains unit 0554 1749 required)

0554 1749 0554 1748 Order no.

0554 0525

Saveris protective housing for protection from high-pressure cleaning and impact, IP 69 K suitable for wireless probes T1 / T1D / T2 / T2D / Pt / PtD / H4D

0572 0200

CFR software, incl. Ethernet connecting cable base-PC Saveris adjustment software incl. connection cable to wireless and Ethernet probes Calibration certificates ISO temperature calibration certificate; temperature probe; calibration points -8 °C, 0 °C, +40 °C; per channel/instrument (suitable for Saveris T1/T2)

Order no.

Alarm module (visual + acoustic), can be connected to base alarm relay

0572 0180 0572 0181

3

0572 0182 0572 0183 Order no. 0520 0171

ISO temperature calibration certificate; temperature probe; calibration points -18 °C, 0 °C, +60 °C; per channel/instrument (suitable for Saveris T1/T2)

0520 0151

DAkkS temperature calibration certificate*; temperature probe; calibration points -20 °C, 0 °C, +60 °C; per channel/instrument (suitable for Saveris T1/T2)

0520 0261

ISO humidity calibration certificate; humidity probe; calibration points 11.3 % RH and 75.3 % RH at +25 °C/+77 °F; per channel/instrument

0520 0076

DAkkS humidity calibration certificate*; humidity probe; calibration points 11.3 % RH and 75.3 % RH at +25 °C/+77 °F; per channel/instrument

0520 0246

*Successor organization of the DKD

2

0572 9999 ID-No. 0699 6111/1

0440 6723

PROF software, incl. USB connecting cable base-PC

Magnetic foot aerial (dual band)

0554 0524

Programming adapter (from Mini DIN to USB) for Base, Ethernet probes and Converters

Software SBE software, incl. USB connecting cable base-PC

1

0515 0414

Spare batteries for radio probes for operation below -10 °C (4 x Energizer L91 Photo lithium)

Mains unit (top-hat rail mounting) 90 to 264 VAC / 24 VDC (2.5 A)

20

Order no.

Saveris protective housing


We measure it.

testo Saveris™ set All components can be assembled individually by you. However, you also have the option of ordering a testo Saveris set. This can be supplemented with further components as required.

Set: 868 MHz, consisting of base 0572 0260, 3 NTC radio probes without display 0572 1250, mains unit for base 0554 1096 and SBE software 0572 0180 incl. USB cable

Set / 2.4 GHz Order no. 0572 0250

Adjustment All testo Saveris probes are of course adjusted in the factory, as confirmed by an adjustment report. You can perform further calibrations or adjustments either yourself on site, via a service provider or in a calibration laboratory. The separate Saveris adjustment software is available for this. After successful adjustment, the current adjustment data is stored in the probe. At the same time, the adjustment software and the Saveris software accept this data so that the adjustment histories are available. Radio and Ethernet probes are connected to a cable via the service interface for adjustment. If you do not wish to perform your own calibration, Testo is available as a service provider.

Saveris adjustment software incl. connection cable to wireless and Ethernet probes Order no. 0572 0183

21


Saveris

Service

Testo is a manufacturer of measuring instruments and measuring systems with a global presence, with 27 international subsidiaries and representatives in numerous countries. Naturally, testo also offers you onsite service. For questions regarding testo SaverisTM, from installation to retrofitting further system components, please refer to your competent contact in your country. You can find an overview of the nearest service location at www.testo.com

22


We measure it.

23


0981 8164/msp/Si/Q/01.2012

Subject to change without notice.

Saveris We measure it.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.