Quantec - Addressable Call System Overview Quantec is a powerful yet easy to use addressable call system that helps ensure vital communication throughout a building. The way the system operates can be tailored to suit a care facility’s specific requirements with different day, night and call divert arrangements easily accommodated to meet the exact operational needs and precise layout of any building. This flexibility, coupled with many advanced features such as multiple call levels and full monitoring of all network devices, makes Quantec the obvious choice for larger nursing homes.
Images show from left to right Quantec call point with reset button and Quantec display unit with controls
Features • Multiple call levels including standard, en suite, help required, emergency, attack, presence & attendance • Tailored to suit a site’s exact operational requirements • Call accept feature & Automatic call divert • Illuminates overdoor lights and corridor lights • Staff attendance allows staff entering rooms to log their ‘attendance’ via an infrared call point or ceiling receiver • Call follower sounders (optional) • Night mode allows Quantec to work in a totally different way at night, providing for fewer staff and reduced sound levels • Infrared staff protection helps protect staff against disturbed patients, intruders and aggressive visitors
• ‘Surveyor’ data analysis software allows the outputting of custom reports • Optional paging facilities (DECT telephone capability also available) • Laptop programmable system controller • Minimising disturbance, with no expensive rewiring • Easy to install & expand • Low maintenance time and costs • New for 2016- a cost-effective expansion kit that adds true BS8300 compliant accessible toilet alarm functionality to a Quantec Addressable Call System (order code N/QT951)
1000s of Sites Are Benefitting from the Quantec Addressable Call System...
Quantec - Typical System Architecture Max. 32 x N/QT606As per system N/QT606A
N/QT608C
door contacts
N/QT607
N/QT60
N/QT607
Max. 3 x N/QT607s per master call point
N/QT608C
N/QT302RXS N/QT302RX Max. 3 x N/QT302RX s per master ceiling receiver
N/QT606
N/QT602
Todmorden House (Health Centre) Yorkshire Programming PC
N/QT602
N/Q T603
N/QT602
SPINE 100m = 1.0mm2 twin and earth 150m = 1.5mm2 twin and earth 250m = 2.5mm2 twin and earth
N/QT604
N/QT606
N/Q T606
240V a.c.
N/QT601-2
A maximum of 10 network devices can be connected to each of the QT603’s 6 outputs
to next N/QT603
St Kentigerns (Hospice) North Wales
LIMB 40m = 4 core stranded alarm cable 60m = 8 core stranded alarm cable
N/QT603
N/QT606