A0.01
Site + Location Plan
1:500 / 200
A1.01 A1.02 A1.03
Ground + First Floor Plan Second + Roof Plan Ceiling - Ground + First Floor Electrical + Lighting Ceiling - Second Floor Electrical + Lighting
1:100 1:100 1:100
A2.01
Elevations
1:100
A3.01 A3.02 A3.03 A3.04 A3.05 A3.06
Sections Sections Sections Sections Sections Sections
1:50 1:50 1:50 1:50 1:50 1:50
A4.01 A4.02 A4.03 A4.04 A4.05 A4.06 A4.07 A4.08
Details Details Details Details Details Details Details Details
1:10 1:10 1:10 1:5 1:5 1:5 1:5 1:5
A5.01 A5.02 A5.03
Stair + Balustrade Details Stair + Balustrade Details Stair + Balustrade Details
1:50 1:5 1:50
A6.01
Door + Window Schedule
1:50
A7.01 A7.02 A7.03 A7.04 A7.05
Lobby Internal Elevations + Details Accessible Shower + WC Lobby + Kitchenette Entry Lobby Details Door Details
1:25/1:5 1:25 237 - 241 High St 1:25 1:25 7 March 2013 1:5
A1.04
1:100
Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
BUILDING CONSENT ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work.
1
4795
2
4800
3
3115
4
b'dry
t
Site area: 300m2 PROPOSED BLDG. FOOTPRINT HATCHED
B
C
Building area: Footprint - 255m2 Site coverage - 85%
3600
b'dry
D
GFSL +0 AOD 15.40
b'dry
re e
2400
St
3600
h
237-241 High Street Central City Lot 2 DP46755
N
Hi g
2925
A
3600
E
3775
ROW by T40970 T37748 Deed 85811
F
Lichfield Street
G
b'dry
237 - 241 High St Location Plan
Site Plan
Site + Location Plan 1:500 / 1:100 at A2 Drwg A0.01 13 March 2013
Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work.
1
4795
2
4800
3
3115
1
4
4795
2
4800
3
4
3115
1
A Kitchen
2925
2925
A
B
1
2400
2400
B
WC Lobby
C
C 1 3600
3600
1
Office
Acc WC /Shr
Acc WC /Shr
D
D
Retail Lift 3600
3600
Lift
E
Lobby
3600
3600
Stair
E
Smoke Lobby
F
3775
3775
F
Stair
Lobby
G
G
1
4
First Floor Plan
LEGEND :
WALL TYPE LEGEND :
ROOF LEGEND :
TIMBER TREATMENTS
N
Ground Floor Plan
237-241 High St Ground and First Floor Plan 1:100 at A2 Drwg A1.01 13 March 2013
Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work.
1
4795
2
4800
3
1
4
3115
2
4795
4800
2
3
3115
4
1
1
A
A
B
2925
2925
Kitchen
B 2400
2400
1
WC Lobby
C
C
4
1 3600
3600
1
Acc WC /Shr
D
D
1
Lift
3600
3600
Office
Lobby
E
3600
3600
E
1
F 3775
3775
Stair
F
3
G
G
Roof Plan
Second Floor Plan
ROOF LEGEND : WALL TYPE LEGEND :
N
LEGEND :
237-241 High St Second and Roof Plan 1:100 at A2 Drwg A1.02 13 March 2013
Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work.
1
4795
2
3
4800
3115
4
1
A
2
4795
4800
3
4
3115
2925
2925
A
B
Kitchen
2400
2400
B
C
WC Lobby
3600
3600
C
Acc WC /Shr
Acc WC /Shr
D
D
Retail
Office
3600
Lift
1
Smoke Lobby
Lobby
E
Lift
3600
1
E
Lobby
F
3775
3775
F
G
167 1033 167
3600
3600
1
G
1
5
4
First Floor Reflected Ceiling Plan N
Ground Floor Reflected Ceiling Plan CEILING PLAN LEGEND :
237-241 High St Ceiling Plans 1:100 at A2 Drwg A1.03 13 March 2013
Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work.
1
2
4795
4800
3
4
3115
2400
2925
1550
A
2400
B
WC
3600
C
2400
2400
Lobby
Acc WC /Shr
3600
2400
D Lift
2400
Office
E
2400
3600
Lobby
1550
3775
2400
F
G
Second Floor Reflected Ceiling Plan N
3
237-241 High St 2
CEILING PLAN LEGEND :
Ceiling Plans 1:100 / 1:10 at A2 Drwg A1.04 13 March 2013
Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work. FINISHES KEY :
1
3
2
A
B
C
D
E
F
G
4
6
4
4
4
2
3
1
L2
L2
2
L1
L1
6
ring u d d e e issu b o T . ance y e b a In ss. e c o r P r Tende
5
7
7 GF
5
GF
Northeast Elevation 4
Southeast Elevation
3
2
G
F
E
D
C
B
A
4 6
4
1
2
1
L2
L2
5 L1
L1
A
237 - 241 High St
5
Elevations
GF 5
GF
1:100 at A2 Drwg A2.01 13 March 2013 Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
Southwest Elevation
Northwest Elevation
TENDER ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work.
G
F
E
D
C
B
A
2
2
1
2 3
Riser
3
Stair / Lift Lobby
Acc.WC/Shwr.
5
WC
Kitchenette
L2
Riser
4
Acc.WC/Shwr.
WC
Kitchenette
L1
4
4
4
1
Stair / Lift Lobby
Riser
5
Lift
Acc.WC/Shwr.
3
1
Retail
GF 6 1
237 - 241 High St Sections
SECTION
A-A
1:50 at A2 Drwg A3.01 13 March 2013 Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work. G
F
E
D
C
B
A
2 2
1
1
2
2
3
3
5
5
Open Plan Office L2
4
4
2
Open Plan Office L1
4
1
4
3
Retail
4
GF 6
237 - 241 High St Sections
SECTION B-B
1:50 at A2 Drwg A3.02 13 March 2013 Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work.
2
1
3
4
1
parapet
truss seat
Open Plan Office L2 tt u/side
Open Plan Office L1 tt u/side
Retail
Stair / Lift Lobby
GF 1
237 - 241 High St Sections
S E C T I O N C -C
1:50 at A2 Drwg A3.03 13 March 2013 Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work. 1
3
2 1
4
1
parapet
truss seat
Stair / Lift Lobby Open Plan Office L2 tt u/side
Open Plan Office
Smoke Lobby
Stair / Lift Lobby
L1 tt u/side
Retail
Stair / Lift Lobby
GF
237 - 241 High St Sections
SECTION D-D
1:50 at A2 Drwg A3.04 13 March 2013 Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work. 1
2
3
4 1
parapet
truss seat 1
Open Plan Office L2 tt u/side
Open Plan Office L1 tt u/side
Retail
Lift Shaft
GF
237 - 241 High St Sections
SECTION E-E
1:50 at A2 Drwg A3.05 13 March 2013 Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work. 1
3
2
2
1
2
1
4
2
1
parapet
truss seat
Open Plan Office
Kitch.
Open Plan Office
Kitch.
L2 tt u/side
L1 tt u/side
Retail GF
237 - 241 High St Sections
SECTION F-F
1:50 at A2 Drwg A3.06 13 March 2013 Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work.
1
2
237-241 High St Roof Details 1:10 at A2 Dwg A4.01 13 March 2013
Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work.
MOUNTING BRACKET
2 3
237-241 High St Roof Details 1:10 at A2 Dwg A4.02 13 March 2013
Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work.
3
4
237-241 High St Window Details 1:10 at A2 Dwg A4.03 13 March 2013
Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work.
0.55BMT COLORSTEEL PARAPET CAPPING ON BUILDING PAPER SEPARATION LAYERON H3.2 TIMBER PACKER SLOPED TO FALL OVER CONCRETE PANEL . FIX THROUGH SIDES AS SHOWN VARIANT 5
H3.2 TIMBER INFILL FRAMING BETWEEN SHS
3. mesh (2 mm max. weave) 4. 15mm H3cca ply sarking 5. underlay separation layer 6.Fibre cement backing sheet flush joint paint finish 7. H3.2 20x40 cavity battens angled 5 degrees at bottom
STRUCTURAL STEEL REFER TO ENGINEER'S DWGS.
SEPARATION BARRIER BETWEEN CONCRETE AND FLASHING. (SELF-ADHESIVE TAPE OR SIMILAR) COLORSTEEL APRON FLASHING & UPSTAND WITH HEMS AT EACH EDGE
100 mm from paved gl
60 mm
3
100
70
70
RIVETS @ 600 C/C MAX. PACK OUT 20mm H3.2 BLOCKING TO VENT CAVITY. CLIP ON CONCEALED FIX AT BRICK SIDE
4
1
6
2
END OF TRAY Zinc cladding Dexter staggered
ALUMINIUM RIVETS AT 1000mm CENTERS
4
5
7
4 3
35
EXTEND 2 RIB MIN.
100
ROOFING -COLORSTEEL PROFILED METAL ROOF SHEET -UNDERLAY - H1.2 90x45 PURLINS AT 1200 MAX.CTRS. -STRUCTURAL PLY ( REFER TO ENG.DWGS.) -H1.2 140x45 TIMBER PURLINS ( REFER TO ENG.DWGS.) WITH 140mm FIBREGLASS BATT INSULATION TO R3.2 -TIMBER ROOF TRUSSES@ 2400 CTRS.
60
110
70
2
STRUCTURAL STEEL REFER TO ENGINEER'S DWGS.
10mm
10 9
H3.2 TIMBER INFILL FRAMING BETWEEN SHS
6 1
HEAD CAPPING Zinc cladding Dexter staggered
8
7
th=0.8 mm, w=80 mm, 2 per m 3. mesh (2 mm max. weave) th=1 mm, w=250 mm, 2 per m 6. 15mm H3cca ply sarking 7.separation layer underlay 8.Fibre cement backing sheet flush joint paint finish 9. H3.2 20x40 cavity battens
900 3 DEXTER PANELS OF 300mm EACH
3
13mm GIB BOARD CEILING LININGS ON METAL BATTENS FIXED TO PURLINS
8
7
50 MIN.
10mm STANDARD GIB BOARD LINING ON H1.2 90mm TIMBER STUD WALL TIED BACK TO CONCRETE GABLE WITH 100mm RIGID INSULATION ZONE BATTENED OFF CONCRETE WALL, PROVIDE DPC TO SEPARATE TIMBER & CONCRETE
7 H3.2 TIMBER INFILL FRAMING BETWEEN SHS, REFER TO ENG.DWGS FOR STEEL
8 7
9
5
9 4
2
4
1
1
3 6
3
2
WALL JUNCTION Zinc cladding Dexter staggered
LINE OF MEMBRANE LAPPING UP & OVER ROOF BATTEN UNDER ROOF SHEET
END CAPPING Zinc cladding Dexter staggered
3. sliding clips 4. 15mm H3cca ply sarking 5. concrete wall
OVERFLASH BUTYNOL UPSTAND WITH COLORSTEEL
100
150
UPTURN ROOF FLASHING AT GUTTER TO DIRECT INTO GUTTER
* All external corners must be beveled and internal corners must have minimum 50mm angle fillet * All corners must be double thickness
4
LAP UNDERLAY INTO GUTTER
7.separation layer underlay 8.Fibre cement backing sheet flush joint paint finish 9. H3.2 20x40 cavity battens
SIM
450
BUTYNOL MEMBRANE BASE SHEET RECESS IN SUBSTRATE
BUTYNOL MEMBRANE CAP SHEET BUTYNOL MEMBRANE BASE SHEET
FIBREGLASS INSULATION LAYER
REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR 125MM CONCRETE TOPPING SLAB OVER DOUBLE T BEAMS
296
TIMBER ROOF PURLINS FIXED AT GABLE WALL AS PER STRUCTURAL DWGS. PRECAST CONC. PANEL
MULSEAL LAYER X 3
44
* All external corners must be beveled and internal corners must have minimum 50mm angle fillet * All corners must be double thickness
H3CCA PLY SUBSTRATE SLOPED TO FALLS & BLOCKED @ 400 CTRS. RECESSED FOR MEMBRANE AT OUTLET TO SPECIFICATION
CAVITY
VITREOUS CLAY BRICK WITH CAVITY TIES TO CONCRETE AS SPECIFIED
PROPRIETARY SCUPPER OUTLET CUT TO SUIT MIN.200x50 OPENING AREA
899
44
BUTYNOL MEMBRANE CAP SHEET TO RUN OVER SCUPPER FLANGE
237-241 High St Window Details 1:5 at A2 Drwg A4.04 13 March 2013
13mm GIB BOARD CEILING LININGS ON METAL BATTENS FIXED TO PURLINS
H3.2 TIMBER SLOPED PACKER ON DPC UNDER AS SCUPPER SUPPOERT
14
Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work.
REINFORCED MESH AT MAX. 400 CRS VERTICALLY
REINFORCED MESH AT MAX. 400 CRS VERTICALLY
REINFORCED MESH AT MAX. 400 CRS VERTICALLY REINFORCED MESH AT MAX. 400 CRS VERTICALLY
1430 10016100
7910
50 50 16
1079
1050
237-241 High St Window Details 1:20 /1:5 at A2 Drwg A4.05 13 March 2013 6 16 50
161
50
115
Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work.
REINFORCED MESH AT MAX. 400 CRS VERTICALLY
REINFORCED MESH AT MAX. 400 CRS VERTICALLY
REINFORCED MESH AT MAX. 400 CRS VERTICALLY
REINFORCED MESH AT MAX. 400 CRS VERTICALLY
REINFORCED MESH AT MAX. 400 CRS VERTICALLY
237-241 High St Window Details 1:5 at A2 Drwg A4.06 13 March 2013
Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work.
237-241 High St Window Details 1:100 at A2 Drwg A4.08 13 March 2013
Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
REFER TO A7.04 FOR DETAILS & LAYOUT
REFER TO A7.04 FOR DETAILS & LAYOUT
237 - 241 High St Internal Elevations - Stair 1:50 at A2 Drwg A5.01 13 March 2013
Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
180
15
120
105
84
90
23
90
100
15
120
10 0.5
20
97
120
3
13
32 84
40
10
10
74
32
48
32
21
74
21
1010
90
40
237-241 High St Stair Details 1:5,1:2 at A2 Drwg A5:02 13 March 2013
Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
237 - 241 High St Internal Elevations - Stair 1:50 at A2 Drwg A5.03 13 March 2013
Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work.
GENERAL NOTES : WINDOW LOCKING AND OPENING CONTROLS ARE LOCATED BETWEEN 900MM AND 1200MM ABOVE FLOOR LEVEL
237 - 241 High St Door + Window Schedule 1:50 at A2 Drwg A6.01 13 March 2013 Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work.
Wc
Lobby
Wc Elevation A
Hall Elevation B
Wc Elevation C
Hall Elevation C
Wc Elevation B
Hall and Wc Plan
Wc Elevation D
Hall Elevation D
237 - 241 High St WC + Hall Internal Elevations 1:25 at A2 Drwg A7.01 13 March 2013
Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work.
3
1 1 1
1
1
2
3 1
1
2
1
1
2
3D of Continuous Steel Rail
Acc WC/Shr
Acc wc Elevation A
Acc wc Elevation B
Detail 01 - Shower Floor/Wall Junction 1:5
Acc wc Elevation C
Acc wc plan
Acc wc Elevation D
237 - 241 High St Accessible WC Internal Elevations 1:25 at A2 Drwg A7.02 13 March 2013
Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work.
JOINERY LEGEND :
Detail 01 - Wall/Bench Junction 1:5
Kitchen Elevation A
Kitchen Elevation B
Kitchen Plan
Kitchen Elevation C
237 - 241 High St Kitchenette Internal Elevations 1:25 at A2 Drwg A7.03 13 March 2013
Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work.
Stairwell Plan
1
2
1
2
Stairwell Section 2
Detail - 01 Split Batten Panels Scale1:2
237 - 241 High St Stairwell Internal Elevations 1:25/1:2 at A2 Drwg A7.04 13 March 2013
Stairwell Elevation A
Stairwell Section 1
Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE
All dimensions to be verified onsite before producing shop drawings or commencing any work.
Fire Door Head Detail
Fire Door Head Detail
Fire Door Jamb Detail
FIRE DOOR JAMB DETAIL WITH HINGE
FIRE DOOR JAMB DETAIL WITH HINGE
Door Type - A
Door Type - B
VP30i Fire Door with Architrave Detail
VP60a Fire Door with Flush to Wall
TIMBER INTERNAL DOOR HEAD DETAIL
FIRE DOOR JAMB DETAIL
TIMBER DOOR HEAD DETAIL
237 - 241 High St TIMBER DOOR JAMB DETAIL
TIMBER JAMB DETAIL WITH HINGE
TIMBERDOOR JAMB DETAIL WITH HINGE
Door Type - C
Door Type - D
Timber Door with Architrave Detail
Timber Door Flush to Wall
TIMBER DOOR JAMB DETAIL
Internal Door Details 1:5 at A2 Drwg A7.05 13 March 2013
Leadbetter Carr Architects 03 377 1210 www.leadbettercarr.co.nz
TENDER ISSUE