tion, able to compensate for routine machine main-tenance without sacrificing operating flexibility. The innovative digital control of all stages of power ensures a low susceptibility network disconnections, preventing unwanted disconnections in the presence variations or micro-breaks. Sirio EVO inverters integrate protections against voltage surges in input and ou-tput and are equipped with control de-vices and redundancy protection, par-ticularly on the output stage, a further guarantee of operational effectiveness and continuity.
t “ t i e t t
s m t a
i t
w
32
01
33
Sirio EVO 1500
INVERTER TL
FeatURes tl inVeRteRs
MoDel VDE aR-N-4105
sirio eVo 1500 Approximate power of the photovoltaic field
VDE 0126-1-1
1700 Wp max ; 1200 Wp min Rated AC power
G83/1
gRiD connecti on cRiteRia
1500 W Maximum AC power
Real Decreto 1663-2000
1500 W inPUt
The entire range can be configured according to the following standards:
PO12.3
CEI 0-21
Each device has an internal type B differential protection in compliance with Standard IEC 60755
CEI 0-16
class b DiFFeRential
Maximum DC voltage in an open circuit 800 Vdc MPPT operating range 100รท720 Vdc
MPPT at full rating range 170÷7 20 Vdc Worki ng range 100÷8 00 Vdc
2
Power factor
MPPT number
from 0,9 ind. to 0,9 cap. (1) Galvanic separation
1 DC connectors
No
MC4 type or compatible
AC connectors Wieland RST25 connector
Directives: 2006/95/CE - EN62109 coMMUn ication
325
oUtPUt
sYsteM Maxi mum input curren t 10 Adc Voltag e during syste m startu p
230 Vac Operating interval
Maximum power range 200÷276 Vac
Frequency range
Settable frequency range
Shutd own voltag e 60 Vdc Ripple voltag e <3% Numb er of inputs
47÷52 Hz
01
Display: LCD 2line, 16 characte rs
eMc: Directive 2004/108/CE, EN61000-6-3: 2007, EN61000-6-2: 2005 555
(1)
Vdc
Vdc
colour: RAL 3020
184÷276 Vac (1)
47,5÷51,5 Hz (1)
130
stanDaRDs
Operating voltage
90
Initial feedin g voltag e
ModBUS and Ethernet optional (slot version)
590
Dimensions (WxDxh): 325x168,5x590 mm
communi cation interface: RS485, USB and dry contact supplied as standard ,
(1)
Nominal current 6,5 Aac Maximum current 7,5 Aac
grid monitoring: CEI 0-21, CEI 0-16, A70, VDE AR-N4105, VDE 0126-1-1,
532
G83/1, Real Decreto 16632000, PO12.3
Weight: 24 kg
Maximum efficiency 96,65%
Fault level contribution
European efficiency
7,5
>93,3%
Aac DC current injection
Stand-by consumption
Protection level: IP65
~9W (1) These values can vary depending on the local regulations.
<32 mA
Night consumption 1W (4W if night-time consultation is active)
Current Harmonic Distorsion (THDi) <4%
DC/DC Converter Single phase inverter
Internal protections acoustic noise: <35dBA
Protection DC/AC side
Detecting earth leakage (RCD type B in accordan ce with IEC 60755).
Overvolta ge protectio n (OVR type 3) Off-Grid protectio n
ENS + GFCI
Yes PV ARRAY
Heat dissipation
EMC Filter
Convection
EMC Filter
Operating temperature
GRID
-20°C÷60°C (+45°C without derating)
168.5
Storage temperature -20°C÷70°C Humidity 4÷100% condensing
Redundant Control System
Dependin g on the local regulatio ns Local & Remote Commutation
www.aros-solar.com
www.aros-solar.com
34
01
35
Sirio EVO 2000
INVERTER TL
FeatURes tl inVeRteRs
MoDel VDE aR-N-4105
sirio eVo 2000 Approximate power of the photovoltaic field
VDE 0126-1-1
2300 Wp max ; 1600 Wp min Rated AC power
G83/1
gRiD connecti on cRiteRia
2000 W Maximum AC power
Real Decreto 1663-2000
2000 W inPUt
The entire range can be configured according to the following standards:
PO12.3
CEI 0-21
Each device has an internal type B differential protection in compliance with Standard IEC 60755
CEI 0-16
class b DiFFeRential
Maximum DC voltage in an open circuit 800 Vdc MPPT operating range 100รท720 Vdc
MPPT at full rating range 220÷7 20 Vdc Worki ng range 100÷8 00 Vdc
2
Power factor
MPPT number
from 0,9 ind. to 0,9 cap. (1) Galvanic separation
1 DC connectors
No
MC4 type or compatible
AC connectors
Directives: 2006/95/CE - EN62109 coMMUn ication
ModBUS and Ethernet optional (slot version)
325
Wieland RST25 connector oUtPUt stanDaRDs sYsteM
Maxi mum input curren t 10 Adc Voltag e during syste m startu p
Operating voltage 230 Vac Operating interval 184÷276 Vac (1) Maximum power range
Frequency range 47,5÷51,5 Hz (1)
Vdc
Settable frequency range
150 Vdc Shutd own voltag e 60 Vdc Ripple voltag e <3% Numb er of inputs
01
Display: LCD 2line, 16 characte rs
eMc: Directive 2004/108/CE, EN61000-6-3: 2007, EN61000-6-2: 2005 555 590
200÷276 Vac (1)
90
Initial feedin g voltag e
colour: RAL 3020
Dimensions (WxDxh): 325x168,5x590 mm
communi cation interface: RS485, USB and dry contact supplied as standard ,
47÷52 Hz (1) Nominal current 8,7 Aac
grid monitoring: CEI 0-21, CEI 0-16, A70, VDE AR-N4105, VDE 0126-1-1,
532
G83/1, Real Decreto 16632000, PO12.3
DC/DC Converter Single phase inverter
Maximum current 10
Weight: 24 kg
Aac
Maximum efficiency
Fault level contribution
97% European efficiency
10 Aac
>94,75% Protection level: IP65
Stand-by consumption
DC current injection
~9W (1) These values can vary depending on the local regulations.
<43 mA Current Harmonic Distorsion (THDi) <4%
Night consumption 1W (4W if night-time consultation is active)
acoustic noise: <35dBA
Internal protections Protection DC/AC side
Detecting earth leakage (RCD type B in accordan ce with IEC 60755).
Overvolta ge protection (OVR type 3) Off-Grid protection
ENS + GFCI
Yes PV ARRAY
Heat dissipation
EMC Filter
Convection
EMC Filter
Operating temperature
GRID
-20°C÷60°C (+45°C without derating)
168.5
Storage temperature -20°C÷70°C Humidity 4÷100% condensing
Dependin g on the local regulation s
Redundant Control System
Local & Remote Commutation
www.aros-solar.com
www.aros-solar.com
36
01
37
Sirio EVO 3000
INVERTER TL
FeatURes tl inVeRteRs
MoDel VDE aR-N-4105
sirio eVo 3000 Approximate power of the photovoltaic field
VDE 0126-1-1
3450 Wp max ; 2400 Wp min Rated AC power
G83/1
gRiD connecti on cRiteRia
3000 W Maximum AC power
Real Decreto 1663-2000
3000 W inPUt
The entire range can be configured according to the following standards:
PO12.3
CEI 0-21
Each device has an internal type B differential protection in compliance with Standard IEC 60755
CEI 0-16
class b DiFFeRential
Maximum DC voltage in an open circuit 800 Vdc MPPT operating range 150รท720 Vdc
MPPT at full rating range 240÷7 20 Vdc Worki ng range 150÷8 00 Vdc
2
Power factor
MPPT number
from 0,9 ind. to 0,9 cap. (1) Galvanic separation
1 DC connectors
No
MC4 type or compatible
AC connectors Wieland RST25 connector
Directives: 2006/95/CE - EN62109 coMMUn ication
325
oUtPUt
sYsteM Maxi mum input curren t 13 Adc Voltag e during syste m startu p
230 Vac Operating interval
Maximum power range 200÷276 Vac
Frequency range
Settable frequency range
Shutd own voltag e 60 Vdc Ripple voltag e <3% Numb er of inputs
47÷52 Hz
01
Display: LCD 2line, 16 characte rs
eMc: Directive 2004/108/CE, EN61000-6-3: 2007, EN61000-6-2: 2005 555
(1)
Vdc
Vdc
colour: RAL 3020
184÷276 Vac (1)
47,5÷51,5 Hz (1)
220
stanDaRDs
Operating voltage
90
Initial feedin g voltag e
ModBUS and Ethernet optional (slot version)
590
Dimensions (WxDxh): 325x168,5x590 mm
communi cation interface: RS485, USB and dry contact supplied as standard ,
(1)
Nominal current 13 Aac Maximum current 15 Aac
grid monitoring: CEI 0-21, CEI 0-16, A70, VDE AR-N4105, VDE 0126-1-1,
532
G83/1, Real Decreto 16632000, PO12.3
Weight: 24 kg
Maximum efficiency 97,10%
Fault level contribution
European efficiency
15
>95,65%
Aac DC current injection
Stand-by consumption
Protection level: IP65
~9W (1) These values can vary depending on the local regulations.
<65 mA
Night consumption 1W (4W if night-time consultation is active)
Current Harmonic Distorsion (THDi) <3,5%
DC/DC Converter Single phase inverter
Internal protections acoustic noise: <35dBA
Protection DC/AC side
Yes (RCD type B in accordan ce with IEC 60755).
Heat dissipation
PV ARRAY
Convection
EMC Filter
Operating temperature
EMC Filter GRID
-20°C÷60°C (+45°C without derating) 168.5
Overvolta ge protection (OVR type 3)
Storage temperature
Off-Grid protection
4÷100% condensing
-20°C÷70°C Humidity
Redundant Control System
Dependin g on the local regulation s Detecting earth leakage
Local & Remote Commutation
ENS + GFCI
www.aros-solar.com
www.aros-solar.com
38
01
39
Sirio EVO 4000
INVERTER TL
FeatURes tl inVeRteRs
MoDel VDE aR-N-4105
sirio eVo 4000 Approximate power of the photovoltaic field
VDE 0126-1-1
4600 Wp max ; 3200 Wp min Rated AC power
G59/2
gRiD connecti on cRiteRia
4000 W Maximum AC power
Real Decreto 1663-2000
4000 W inPUt
The entire range can be configured according to the following standards:
PO12.3
CEI 0-21
Each device has an internal type B differential protection in compliance with Standard IEC 60755
CEI 0-16
class b DiFFeRential
Maximum DC voltage in an open circuit 800 Vdc MPPT operating range 150รท720 Vdc
MPPT at full rating range 270÷7 20 Vdc Worki ng range 150÷8 00 Vdc
2
Power factor
MPPT number
from 0,9 ind. to 0,9 cap. (1) Galvanic separation
1 DC connectors
No
MC4 type or compatible
AC connectors
Directives: 2006/95/CE - EN62109 coMMUn ication
ModBUS and Ethernet optional (slot version)
325
Wieland RST25 connector oUtPUt stanDaRDs sYsteM
Maxi mum input curren t 16 Adc Voltag e during syste m startu p
Operating voltage 230 Vac Operating interval 184÷276 Vac (1) Maximum power range
Frequency range 47,5÷51,5 Hz (1)
Vdc
Settable frequency range
220 Vdc Shutd own voltag e 60 Vdc Ripple voltag e <3% Numb er of inputs
01
Display: LCD 2line, 16 characte rs
eMc: Directive 2004/108/CE, EN61000-6-3: 2007, EN61000-6-2: 2005 555 590
200÷276 Vac (1)
90
Initial feedin g voltag e
colour: RAL 3020
Dimensions (WxDxh): 325x168,5x590 mm
communi cation interface: RS485, USB and dry contact supplied as standard ,
47÷52 Hz (1) Nominal current 17,4 Aac
grid monitoring: CEI 0-21, CEI 0-16, A70, VDE AR-N4105, VDE 0126-1-1,
532
G59/2, Real Decreto 16632000, PO12.3
DC/DC Converter Single phase inverter
Maximum current 20
Weight: 24 kg
Aac
Maximum efficiency
Fault level contribution
97,10% European efficiency
20 Aac
96,15% Protection level: IP65
Stand-by consumption
DC current injection
~9W (1) These values can vary depending on the local regulations.
<87 mA Current Harmonic Distorsion (THDi) <3,5%
Night consumption 1W (4W if night-time consultation is active)
acoustic noise: <35dBA
Internal protections Protection DC/AC side
Detecting earth leakage (RCD type B in accordan ce with IEC 60755).
Overvolta ge protection (OVR type 3) Off-Grid protection
ENS + GFCI
Yes PV ARRAY
Heat dissipation
EMC Filter
Convection
EMC Filter
Operating temperature
GRID
-20°C÷60°C (+45°C without derating)
168.5
Storage temperature -20°C÷70°C Humidity 4÷100% condensing
Dependin g on the local regulation s
Redundant Control System
Local & Remote Commutation
www.aros-solar.com
www.aros-solar.com
40
41
01
Sirio EVO 5000 inVeR teRs
INVERTER TL Real Decreto 1663-2000
sirio eVo 500 0
PO12.3
App roxi mat e pow er of the pho tovo ltaic field
class b DiFFeRential
Each device has an internal type B differential protection in compliance with Standard IEC 60755
gRiD connection cRiteRia 575 0 Wp ma x; 400 0 Wp min
The entire range can be configured according to the following standards: CEI 0-21
CEI 0-16 (1) These values can vary depending on the local regulations.
VDE aR-N-4105
Rat ed AC pow er
VDE 0126-1-1
500 0W G59/2
MoDel
Maximum AC power
4
DC current injection
MPPT number 5000 W inPUt
<108 mA 2
Current Harmonic Distorsion (THDi)
DC connectors <3% Maximum DC voltage in an open circuit
MC4 type or compatible
Power factor
oUtPUt
800 Vdc
from 0,9 ind. to 0,9 cap. (1)
MPPT operating range Galvanic separation Operating voltage 150÷720 Vdc
Ove rvolt age prot ecti on (OV R type 3) OffGri d prot ecti on
No MPPT at full rating range 230 Vac
AC connectors
Operating interval 240÷720 Vdc Terminal block 16mm2
Working range 184÷276 Vac (1)
sYsteM
Maximum power range 150÷800 Vdc
Dep endi ng on the loca l reg ulati ons
Maximum input current 200÷276 Vac (1) 13Adc/MPPT
Stand-by consumption
Hea t diss ipati on
Settable frequency range
Initial feeding voltage 47÷52 Hz (1) Nominal current
~9W
Shutdown voltage
60 Vdc
Yes
97,15% 47,5÷51,5 Hz (1)
220 Vdc
> 96%
Frequency range
Voltage during system startup
110 Vdc
European efficiency
Det ecti ng eart h leak age
Maximum efficiency
21,7 Aac
Night consumption
Maximum current
1W (4W if night-time consultation is active) Internal protections
Ripple voltage 25 Aac <3%
Fault level contribution
Protection DC/AC side
25 Aac
(RCD type B in accordance with IEC 60755).
Number of inputs
Con vect ion Op erat ing tem per atur e
-20°C÷60°C (+45°C without derating)
Protection level: IP65
Storage temperature stanDaRDs -20°C÷70°C
630
Humidity
acoustic noise: <35dBA
682
4÷100% condensing
FeatURes 424
eMc: Directive 2004/108/CE, EN61000-6-3: 2007, EN61000-6-2: 2005
612
coMMUnication
colour: RAL 3020
grid monitoring: CEI 0-21, CEI 0-16, A70, VDE AR-N-4105, VDE 0126-1-1,
Display: LCD 2-line, 16 characters
Dimensions (WxDxh): 424x173,5x682 mm
G59/2, Real Decreto 1663-2000, PO12.3
communication interface: RS485, USB and dry contact supplied as standard, 173. 5
Directives: 2006/95/CE - EN62109 Weight: 35 kg
ModBUS and Ethernet optional (slot version)
01 tl
www.aros-solar.com
www.aros-solar.com
42
43
01
Sirio EVO 6000 inVeRt eRs
INVERTER TL Real Decreto 1663-2000
sirio eVo 600 0
PO12.3
App roxi mat e pow er of the pho tovo ltaic field
class b DiFFeRential
Each device has an internal type B differential protection in compliance with Standard IEC 60755
gRiD connection cRiteRia 690 0 Wp ma x; 480 0 Wp min
The entire range can be configured according to the following standards: CEI 0-21
CEI 0-16 (1) These values can vary depending on the local regulations.
VDE aR-N-4105
Rat ed AC pow er
VDE 0126-1-1
600 0W G59/2
MoDel
Maximum AC power
4
DC current injection
MPPT number 6000 W inPUt
<130 mA 2
Current Harmonic Distorsion (THDi)
DC connectors <3% Maximum DC voltage in an open circuit
MC4 type or compatible
Power factor
oUtPUt
800 Vdc
from 0,9 ind. to 0,9 cap. (1)
MPPT operating range Galvanic separation Operating voltage 150÷720 Vdc
Ove rvolt age prot ecti on (OV R type 3) OffGri d prot ecti on
No MPPT at full rating range 230 Vac
AC connectors
Operating interval 270÷720 Vdc Terminal block 16mm2
Working range 184÷276 Vac (1)
sYsteM
Maximum power range 150÷800 Vdc
Dep endi ng on the loca l reg ulati ons
Maximum input current 200÷276 Vac (1) 16 Adc/MPPT
Stand-by consumption
Hea t diss ipati on
Settable frequency range
Initial feeding voltage 47÷52 Hz (1) Nominal current
~9W
Shutdown voltage
60 Vdc
Yes
97,20% 47,5÷51,5 Hz (1)
220 Vdc
96,30%
Frequency range
Voltage during system startup
110 Vdc
European efficiency
Det ecti ng eart h leak age
Maximum efficiency
26 Aac
Night consumption
Maximum current
1W (4W if night-time consultation is active) Internal protections
Ripple voltage 30 Aac <3%
Fault level contribution
Protection DC/AC side
30 Aac
(RCD type B in accordance with IEC 60755).
Number of inputs
Con vect ion Op erat ing tem per atur e
-20°C÷60°C (+45°C without derating)
Protection level: IP65
Storage temperature stanDaRDs -20°C÷70°C
630
Humidity
acoustic noise: <35dBA
682
4÷100% condensing
FeatURes 424
eMc: Directive 2004/108/CE, EN61000-6-3: 2007, EN61000-6-2: 2005
612
coMMUnication
colour: RAL 3020
grid monitoring: CEI 0-21, CEI 0-16, A70, VDE AR-N-4105, VDE 0126-1-1,
Display: LCD 2-line, 16 characters
Dimensions (WxDxh): 424x173,5x682 mm
G59/2, Real Decreto 1663-2000, PO12.3
communication interface: RS485, USB and dry contact supplied as standard, 173. 5
Directives: 2006/95/CE - EN62109 Weight: 35 kg
ModBUS and Ethernet optional (slot version)
01 tl
www.aros-solar.com
www.aros-solar.com
44
45
01
Sirio EVO 10000 inVeRt eRs
INVERTER TL Real Decreto 1663-2000
sirio eVo 100 00
PO12.3
App roxi mat e pow er of the pho tovo ltaic field
class b DiFFeRential
Each device has an internal type B differential protection in compliance with Standard IEC 60755
gRiD connection cRiteRia 115 00 Wp ma x; 800 0 Wp min
The entire range can be configured according to the following standards: CEI 0-21
CEI 0-16 (1) These values can vary depending on the local regulations.
Rat ed AC pow er
VDE aR-N-4105
VDE 0126-1-1
G59/2
available from october 2012
MoDel
100 00 W
220 Vdc 346÷480 Vac (1)
Maximum AC power Shutdown voltage 10000 W inPUt
Frequency range 70 Vdc Ripple voltage
<3% Maximum DC voltage in an open circuit
Number of inputs
1000 Vdc 4 MPPT operating range MPPT number 150÷900 Vdc 2 MPPT at full rating range DC connectors 300÷800 Vdc MC4 type or compatible Working range
18 Adc/MPPT
Voltage during system startup
110 Vdc
Settable frequency range
47÷52 Hz (1)
Nominal current
14,5 Aac
Maximum current
No
AC con nec tors
Wie lan d RS T25 con nec tor sYs teM
17 Aac
Fault level contribution
oUtPUt
17 Aac
150÷1000 Vdc
Maximum input current
47,5÷51,5 Hz (1)
Gal vani c sep arat ion
Ma xim um effic ienc y
DC current injection Operating voltage <72,5 mA 400 Vac
98 %
Current Harmonic Distorsion (THDi)
Operating interval
<4%
318÷480 Vac (1)
Power factor
Maximum power range
from 0,9 ind. to 0,9 cap. (1)
Initial feeding voltage
Eur ope an effic ienc y
97, 6%
Stand-by consumption
-20°C÷70°C
~1W
Humidity
Night consumption
4÷100% condensing
coMMUnication
0,6W (5W if night-time consultation is active)
Internal protections Display: LCD 2-line, 16 characters Protection DC/AC side
FeatURes
(RCD type B in accordance with IEC 60755).
grid mo nito ring : CEI 021, CEI 016, A70 , VD E ARN410 5, VD E 012 6-11,
communication interface: RS485, USB and dry contact supplied as standard, colour: RAL 3020
Overvoltage protection (OVR type 3)
ModBUS and Ethernet optional (slot version)
Off-Grid protection Dimensions (WxDxh): 533x219,5x742 mm
Depending on the local regulations
stanDaRDs
Detecting earth leakage Weight: 50 kg
696.5
G5 9/2, Rea l Dec reto 166 3200 0, PO 12. 3
742
Yes
Heat dissipation Forced (by temperature controlled fans)
Protection level: IP65
Operating temperature
eMc: Directive 2004/108/CE, EN61000-6-3: 2007, EN61000-6-2: 2005
-20°C÷60°C (+45°C without derating) acoustic noise: <35dBA (<45dBA with fans running)
Storage temperature 533
Dire ctiv es: 200 6/9 5/C EEN 621 09
670
Three phase inverter
01 tl
219.5
www.aros-solar.com
www.aros-solar.com
46
47
01
Sirio EVO 12500 inVeRt eRs
INVERTER TL Real Decreto 1663-2000
sirio eVo 125 00
PO12.3
App roxi mat e pow er of the pho tovo ltaic field
class b DiFFeRential
Each device has an internal type B differential protection in compliance with Standard IEC 60755
gRiD connection cRiteRia 145 00 Wp ma x; 100 00 Wp min
The entire range can be configured according to the following standards: CEI 0-21
CEI 0-16 (1) These values can vary depending on the local regulations.
Rat ed AC pow er
VDE aR-N-4105
VDE 0126-1-1
G59/2
available from october 2012
MoDel
125 00 W
220 Vdc 346÷480 Vac (1)
Maximum AC power Shutdown voltage 12500 W inPUt
Frequency range 70 Vdc Ripple voltage
<3% Maximum DC voltage in an open circuit
Number of inputs
1000 Vdc 4 MPPT operating range MPPT number 150÷900 Vdc 2 MPPT at full rating range DC connectors 360÷800 Vdc MC4 type or compatible Working range
18 Adc/MPPT
Voltage during system startup
110 Vdc
Settable frequency range
47÷52 Hz (1)
Nominal current
18 Aac
Maximum current
No
AC con nec tors
Wie lan d RS T25 con nec tor sYs teM
21 Aac
Fault level contribution
oUtPUt
21 Aac
150÷1000 Vdc
Maximum input current
47,5÷51,5 Hz (1)
Gal vani c sep arat ion
Ma xim um effic ienc y
DC current injection Operating voltage <90 mA 400 Vac
98 %
Current Harmonic Distorsion (THDi)
Operating interval
<4%
318÷480 Vac (1)
Power factor
Maximum power range
from 0,9 ind. to 0,9 cap. (1)
Initial feeding voltage
Eur ope an effic ienc y
97, 7%
Stand-by consumption
-20°C÷70°C
~1W
Humidity
Night consumption
4÷100% condensing
coMMUnication
0,6W (5W if night-time consultation is active)
Internal protections Display: LCD 2-line, 16 characters Protection DC/AC side
FeatURes
(RCD type B in accordance with IEC 60755).
grid mo nito ring : CEI 021, CEI 016, A70 , VD E ARN410 5, VD E 012 6-11,
communication interface: RS485, USB and dry contact supplied as standard, colour: RAL 3020
Overvoltage protection (OVR type 3)
ModBUS and Ethernet optional (slot version)
Off-Grid protection Dimensions (WxDxh): 533x219,5x742 mm
Depending on the local regulations
stanDaRDs
Detecting earth leakage Weight: 50 kg
696.5
G5 9/2, Rea l Dec reto 166 3200 0, PO 12. 3
742
Yes
Heat dissipation Forced (by temperature controlled fans)
Protection level: IP65
Operating temperature
eMc: Directive 2004/108/CE, EN61000-6-3: 2007, EN61000-6-2: 2005
-20°C÷60°C (+45°C without derating) acoustic noise: <35dBA (<45dBA with fans running)
Storage temperature 533
Dire ctiv es: 200 6/9 5/C EEN 621 09
670
Three phase inverter
01 tl
219.5
www.aros-solar.com
www.aros-solar.com