Gama LED Parking Lot Lighting

Page 1

Brite Energy Solutions - Tom Knoblock - 1-844-533-2897


Light Module ——LED Optical Engine



ARRLUX

GAMA Series LED Area Light

Huizhou Arrlux Optoelectronic Co.,Ltd

INSTALLATION INFORMATION

PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION W

IMPORTANT INSTALLATION INFORMATION

W

1.Before commencing installa on or maintenance, ensure electricity is switched off at the mains. Installa on or maintenance should be carried out by a qualified electrician. L

2.The luminaire must not, under any circumstances, be installed directly to flammable materials, and luminaires must not be covered with any flammable materials. 3.Moun ng height range of 6 to 12 meters, this model is suitable for outdoor ligh ng. 4.Ensure there is adequate free air circula on of at least 50cm around the luminaire. All luminaires run hot. It is the installer's responsibility to consider fire risk and take appropriate precau ons.

Main specifica ons: Model No.

No. of LEDs

System Wa age

Dimensions (L x W x H)

Net Weight

EPA*

FLB80-T

36

80W

360(14.17")x330(12.99")x70mm(12.76")

5.88kg(12.94lbs.)

0.034m²

FLB120-T

54

120W

420(16.53")x330(12.99")x70mm(12.76")

6.87kg(15.11lbs.)

0.037m²

FLB160-T

72

160W

480(18.90")x330(12.99")x70mm(12.76")

8.38kg(18.44lbs.)

0.041m²

FLB200-T

90

200W

600(23.61")x330(12.99")x70mm(12.76")

9.25kg(20.35lbs.)

0.048m²

FLB240-T

108

240W

660(26.00")x330(12.99")x70mm(12.76")

10.21kg(22.46lbs.)

0.052m²

Working Environment

IP

- 40℃-+50℃

IP65

Working Environment

IP

- 40℃-+50℃

IP65

Input Voltage:120-277V~50/60Hz The ingress protec on of the fixture is IP65 if the mains supply cable's specifica on is H07RN-F 3*1.5m㎡.

Model No.

No. of LEDs

System Wa age

Dimensions (L x W x H)

Net Weight

EPA*

FLC80-T

36

80W

360(14.17")x330(12.99")x70mm(12.76")

5.88kg(12.94lbs.)

0.034m²

FLC120-T

54

120W

420(16.53")x330(12.99")x70mm(12.76")

6.87kg(15.11lbs.)

0.037m²

FLC160-T

72

160W

480(18.90")x330(12.99")x70mm(12.76")

8.38kg(18.44lbs.)

0.041m²

FLC200-T

90

200W

600(23.61")x330(12.99")x70mm(12.76")

9.25kg(20.35lbs.)

0.048m²

FLC240-T

108

240W

660(26.00")x330(12.99")x70mm(12.76")

10.21kg(22.46lbs.)

0.052m²

Input Voltage:347-480V~50/60Hz The ingress protec on of the fixture is IP65 if the mains supply cable's specifica on is H07RN-F 3*1.5m㎡.


LEAVE A COPY FOR THE USER / MAINTENANCE ENGINEER FOR FUTURE REFERENCE

Installa on Instruc on & Installa on Steps Installa on and Moun ng A

1

Installa on and Moun ng A

2 Moun ng arm

Moun ng arm

Pole Pole

Spring washer(M10)

Spring washer(M10)

STEP 1: 1.Loosen the M12 screws, nuts, spring washers on the moun ng arm with a wrench. 2.Insert the pole into the middle hole of moun ng arm ll to the end. See Figure 1.

STEP 2: When the pole is inside the moun ng arm, adjust the moun ng angle of the lamp, then screw the the M12 screws, nuts and spring washers. See Figure 2

Installa on and Moun ng B

3

M10 screw M6 screw

Pole

Installa on and Moun ng B

4

Moun ng plate

STEP 3: 1. Fix the moun ng plate on the pole with M10 screws. 2. Connect the cables from the luminaire and from the pole. Please See figure 3 the wiring diagram.

STEP 4: 1. Fix the luminaire to the moun ng plate with 4 M6*20 screws. See Figure 4

Installa on and Moun ng C

5

Installa on and Moun ng C

6 M10 screw M6 screw

Moun ng plate Wall

Wall

STEP 5: 1. Fix the moun ng plate on the wall with M10 screws. 2. Connect the cables from the luminaire and from the wall. Please See figure 5 the wiring diagram.

STEP 6: 1. Fix the luminaire to the moun ng plate with 4 M6*20 screws. See Figure 6

Safety No ce

Alterna ng Current

WIRING INSTRUCTION ***IF THERE IS JUNCTION BOX IN CEILING: STEP I: Connect the LINE wire in the mains power supply cord to black LINE wire from lightbody . STEP II: Connect the NEUTRAL wire in the mains power supply cord to white NEUTRAL wire from lightbody . STEP III: Connect the green grounding wire in the mains power supply cord to green grounding wire from lightbody .

Input wire H07RN-F 3x1.5mm² (SJOW 3 * 18AWG) or rubber sheathed cable (not supplied).Conductor must have a minimum cross-sec onal area of 1.0mm² (18AWG).

Electrical Connec ons

7

Terminal Block

L

LIVE - Black

GROUND

G

GROUND-Housing

NEGATIVE

N

NEGATIVE - White

LED DrivER

Mains power supply

LIVE

STEP 7: Reference “Electrical Connec ons” sec on for comple ng electrical connec ons. See Figure 7

This logo indicates that this product must not be disposed of with other waste. Please recycle used lamps to prevent environmental hazard and threats to human health resul ng from improper disposal.