Kimbers lighting products

Page 1

Project

Type

Catalog #

DESCRIPTION The Canopy Star canopy LED luminaire from US LED is a perfect solution for parking structures, shopping area walkways, petrol stations and exterior canopies. The Canopy Star LED canopy is surface mounted for easy adaptation with a typical mounting height of 10 to 25 feet. Designed to illuminate area features with sharp, accurate color to increase security and visibility, the Canopy Star is cost effective to install and will replace conventional fluorescent, HPS and metal halide lighting.

Canopy LED Luminaire Standard Flux

FEATURES l l l l l

112 W / 12,600 Lumens

Class 2 compliant design (low voltage, limited power) L70 lifetime of >200,000 hours* Luminaire is IP66 compliant Protective coating added to resist corrosion 5-year warranty

CERTIFICATION l l

UL 1598 approved LM-79 available ENERGY DATA Input Voltage (VAC)

120

12600

12600

System Efficacy (Lm/W)

112.5

105

Color Temperature (K)

5000

5000

L70 Calculated Life (Hrs)* L85 Calculated Life (Hrs)* Operating Temp (ºC)

Example: CNP3-50

CNP3

50

Series

Color Temp (K)

CNP3

347-480

Delivered Lumens (Lm)

Color Rendering Index

FIXTURE ORDERING INFORMATION

120 - 277 112

System Level Power (W)

80 min

80 min

>200,000

>200,000

150,000

150,000

-40 to 50

-40 to 50

* US LED product ‘Lifetimes’ refer only to the LED light engine, not the power source, and are based on the Illuminating Engineering Society’s TM21 methodology based on 25°C/77°F ambient temperature. The lifetimes are solely meant to be a guide for expected LED degradation and not a warranty or predictive of their actual life, which can be affected by ambient temperatures and other factors.

SPECIFICATIONS Dimensions (in) Units/carton

50 5000K

Net weight Environmental Rating

18.62 x 18.62 x 2.75 1 9 lbs Wet

POWER SUPPLY INFORMATION Example: PUC-UNV1-4100

Series

Type

Drive Current

PUC

UNV1- (120-277 VAC)

4100

PUC

UNV2 - (347/480 VAC)

4100

Specifications and dimensions subject to change without notice

DATASHEET 05.30.2014


INSTALLATION GUIDE CNPx-50

WARNING l

The installation must only be performed by a licensed electrician.

l

To prevent death, injury or damage to property, this product must be installed in accordance to National Electrical Code (NFPA70) in the US or Canadian Electrical Code (CSA22.1) in Canada.

l

Disconnect power before installing the product or servicing it.

l

Wait until fixture has cooled down before installing or servicing the fixture.

l

MIN. 90°C SUPPLY CONDUCTORS

MODEL NUMBERS This installation instructions covers the following products: Power Supplies 1. 50W Power Unit: PUC-UNV1-2100 or PUC-UNV2-2100 2. 75W Power Unit: PUC-UNV1-3000 or PUC-UNV2-3000 3. 96W Power Unit: PUC-UNV1-3570 or PUC-UNV2-3570 4. 192W Power Unit: PUC-UNV1-7140 or PUC-UNV2-7140 Luminaires 1. CNP1-50 Series Luminaires 2. CNP2-50 Series Luminaires

BOX CONTENTS

Tools Needed 1. 4” Hole Saw 2. #2 Phillips Screw Driver 3. ¼” Hex Driver

Mounting Plate Assembly

CanopyStar Fixture

LED Driver with Mounting Bracket

Wire Harness/Cover Assembly

Page 1 #44-000017 Updated 09.26.13

US LED


INSTALLATION GUIDE CNPx-50

INSTALLATION INSTRUCTIONS 1. Using 4” hole saw, cut hole in canopy where fixture is to be mounted. Hole location needs to be centered between canopy ribs to allow wire harness/cover assembly to fit. 2.

Install mounting plate assembly by folding mounting tabs in, insert mounting plate into 4” hole and secure by tightening mounting tab screws using #2 Phillips screw driver. See Figures 1 and 2.

Mounting tab screws

4” hole

Mounting tabs

FIG 1

3.

FIG 2

Hang Canopy Fixture on mounting plate assembly by hooking hinge on mounting plate hook. Secure by sliding locking plate forward into slot and tightening #6-32 locknut. See Figures 3 and 4. Locking plate

Locknut

FIG 3

FIG 4

Page 2 #44-000017 Updated 09.26.13

US LED


INSTALLATION GUIDE CNPx-50

INSTALLATION INSTRUCTIONS 4.

Route wires through center of mounting plate assembly. See Figure 5.

5.

Take wire harness assembly and make power connections using approved electrical connector. See wire diagrams.

FIG 5

6.

FIG 6

Pack excess wire in center of mounting plate assembly and mount cover using #10 sealing weather resistant screws supplied. See Figure 7.

7. Complete installation by swinging fixture into place and securing with mounting screws using #2 Phillips driver. See Figure 8.

FIG 7

FIG 8

Page 3 #44-000017 Updated 09.26.13

US LED


INSTALLATION GUIDE CNPx-50

INSTALLATION INSTRUCTIONS - DRIVER BOX 1.

Turn off main power.

2.

Secure driver box assembly to mounting bracket by tightening mounting screws using ¼” hex driver. See Figure 9.

3.

Secure mounting bracket to any vertical wall using #10 sheet metal screws supplied. Insure location allows wire harness to reach low voltage side of power supply box. See Figure 10.

4.

Make internal primary side (high voltage) power connections by connecting wires, Black to Load, White to Neutral and Green to Ground using approved electrical connector. See wire diagrams.

5.

Make secondary (low voltage) connections by using approved electrical connector. See wire diagrams.

6.

Secure driver box top using #8 sealing machine screws supplied.

7.

Turn on power.

Mounting screws

FIG 9

FIG 10

Page 4 #44-000017 Updated 09.26.13

US LED


INSTALLATION GUIDE CNPx-50

WIRING DIAGRAMS FOR CNP1-50 LUMINAIRES WITH TRANSFORMER

WITHOUT TRANSFORMER

Page 5 #44-000017 Updated 09.26.13

US LED


INSTALLATION GUIDE CNPx-50

WIRING DIAGRAMS FOR CNP2-50 LUMINAIRES WITH TRANSFORMER, 2 DRIVERS

WITHOUT TRANSFORMER, 2 DRIVERS

Page 6 #44-000017 Updated 09.26.13

US LED


eLucent™ WP Series LED Wall Pack WPFC Series WP00 Series Dark Sky Compliant

WPDS Series Dark Sky Compliant

WWPW

Family Model WPFC40 WPFC60 WPFC90

WP0040 WP0060 WP0090

Product Description

W

eLucent™ WP Series LED Wall pack is designed for applications that require lighting with a long life and low maintenance requirement.

WPFC40

With effective thermal management, corrosion-resistant, and die-cast aluminum enclosure with an architectural dark brown finish, eLucent™ WP Series LED Wall provides glare free, uniform illumination while providing a safe and comfortable visual experience. eLucent™ WP Series LED Wall pack adopts high luminous efficacy SMD LEDs. They are available in 40 watts, 60 watts and 90watts. With superior 60%-90% energy savings, compared to halogen lamp or a metal halide lamp, eLucent™ WP90 achieves a superlative luminous flux of 8500 lm and only consumes approximate 90 watts.

W WPFC60 & WPFC90

High lumen output, energy-efficient optical control and easy universal installation features confirm the eLucent™ WP Series LED Wall as the absolute choice for indoor and outdoor illumination.

Performance Summary

W WP0040

Power consumption 40W

60W

90W

Lumens

4000 lm

6000 lm

8500 lm

PF/THD

>0.9/<15%

>0.9/<20%

>0.9/<20%

CCT: 5700 K Color Accuracy: CRI 85, R9>20 L70 lifetime: 130,000h W WP0060 & WP0090

www.atgelectronics.com

Toll free: 877-461-5333

E-mail: sales@atgelectronics.com


Ordering Information Typical Order Example: WPFC60HU570000 SERIES

HOUSING

WATT

VOLTAGE

CCT

CONTROL

OPTIONS

WP=Wall Pack

FC=Full Cutoff

40=40W 60=60W 90=90W

HU=100-277V

57=5700K

00=non-dimming

00=Default

Product Specifications CONSTRUCTION & MATERIALS Type

WPFC40 WPFC60 362*293*230 mm 465*350*232 mm Dimension (14.25*11.54*9.06") (18.31*13.78*9.13") Housing Die-cast aluminum Lens Type Glass

WPFC90 WP0040 465*350*232 mm 363*230*195 mm (18.31*13.78*9.13") (14.29*9.06*7.68")

WP0060 465*230*244 mm (18.31*9.06*9.61")

WP0090 465*230*244 mm (18.31*9.06*9.61")

ENVIRONMENTAL SYSTEM Work Environment Operating Temperature

Indoor and outdoor use -20℃~60℃(-4~140℉)

OPTICAL SYSTEM Type Luminous Flux Luminous Efficacy Color Temperature CRI Lumen maintenance at 6000h

WPFC40/WP0040 4000 lm Typ. 100 lm/W 5700 K 85 99%

WPFC60/WP0060 6000 lm

WPFC90/WP0090 8500 lm

WPFC40/WP0040 100~277VAC/0.31A 0W 40W <15% >0.9

WPFC60/WP0060 100~277VAC/0.48A 0W 60W <20%

WPFC90/WP0090 100~277VAC, 0.75A 0W 90W <20%

ELECTRICAL SYSTEM Type Input Voltage Off State Power Power Consumption THD Power Factor REGULATORY & VOLUNTARY

QUALIFICATIONS

ETL & cETL Listed (ETL No.: 4003329) DLC, LM79 CE, RoHS

www.atgelectronics.com

Toll free: 877-461-5333

E-mail: sales@atgelectronics.com


eLucent™ WP Series LED Wall Pack

SIDE

BOTTOM

BACK

TOP


Project

Type

Catalog #

EconoPak

DESCRIPTION EconoPak is a multi-purpose LED luminaire designed for indoor and outdoor area lighting applications. Delivering maximum lumens for 142,000 hours* while using only 30 Watts of power, its compact design with enclosed power supply make it ideal for such applications as flood lighting, sign lighting, landscape and general area lighting. The EconoPak can be mounted to a wall, ceiling or conduit, making it one of the most versatile LED luminaires in the market.

Wall Mount Luminaire

FEATURES l

l l l

Powered by a constant current power supply to achieve maximum efficiency (see separate data sheet) IP65 ingress protection Designed to meet Class 2 safety requirements 5-year warranty

CERTIFICATION l l

UL Listed USA+Canada File # E352127 LM-79 Test Report ENERGY DATA Input Voltage (V AC)

120 - 277

System Level Power (W)

30

Delivered Lumens (Lm)

2500

System Efficacy (Lm/W)

82

Correlated Color Temp (K)

5000

Minimum CRI

70

LED L70 Lifetime (Hrs)*

142,000

Operating Temp (ºC)

-20 to 40

† US LED product ‘Lifetimes’ refer only to the LED light engine, not the power source, and are based on the Illuminating Engineering Society’s TM21 methodology based on 25°C/77°F ambient temperature. The lifetimes are solely meant to be a guide for expected LED degradation and not a warranty or predictive of their actual life, which can be affected by ambient temperatures and other factors.

SPECIFICATIONS Dimensions (in)

7.75 x 6.625 x 4.25

Units/carton

1

Net weight

5.4 lbs

Environmental Rating

Wet

ORDERING INFORMATION Example: TL-WMB301-01-BZ

TL

WMB301

01

Series TL

Color WMB301

01

BZ

Bronze

WH White

Specifications and dimensions subject to change without notice.

|

DATASHEET 04.23.2014

|

|

|

|


Project

Type

Catalog #

DESCRIPTION

QubeLot2

The QubeLot2 evenly illuminates walkways, streets and parking areas. The classic design of this luminaire seamlessly blends into all forms of architecture. Highly efficient and long-lasting, the QubeLot2 is an ideal replacement for HID. Exceptional high-brightness LEDs result in higher light levels and significant energy savings. High-efficiency 5200K LEDs mounted to a metal-core circuit board and aluminum heat sink, ensure optimal thermal management and long life (L85 124,000 hrs).

Parking Lot Luminaire 4-Qube

FEATURES AND SPECIFICATIONS l

Type 5 medium light distribution and Type 2 medium distribution pattern available

l

Comes fully equipped with power supply

l

Bi-level light option available for dimmed-down lower power operation

l

EPA rating of fixture is 0.7/sq ft and mount is 0.13/sq ft

l

5-year warranty

CERTIFICATION l

UL Listed USA and Canada File# E338791

l

DesignLights Consortium qualified

3-QUBE

4-QUBE

ENERGY DATA Input Voltage (V AC)

ENERGY DATA 120 - 480

System Level Power (W)

Input Voltage (V AC)

104

Delivered Lumens (Lm)

9300

System Efficacy (Lm/W)

136

Delivered Lumens (Lm)

89

Correlated Color Temp (K)

120 - 480

System Level Power (W)

12,300

System Efficacy (Lm/W)

5200K

90

Correlated Color Temp (K)

5200K

L70 Calculated Life (hrs)*

289,000

L70 Calculated Life (hrs)*

289,000

L85 Calculated Life (hrs)*

124,000

L85 Calculated Life (hrs)*

124,000

Minimum CRI

65

Operating Temperature (°C)

Minimum CRI

-40 to 45

65

Operating Temperature (°C)

-40 to 45

* US LED product ‘Lifetimes’ refer only to the LED light engine, not the power source, and are based on the Illuminating Engineering Society’s TM21 methodology based on 25°C/77°F ambient temperature. The lifetimes are solely meant to be a guide for expected LED degradation and not a warranty or predictive of their actual life, which can be affected by ambient temperatures and other factors.

* US LED product ‘Lifetimes’ refer only to the LED light engine, not the power source, and are based on the Illuminating Engineering Society’s TM21 methodology based on 25°C/77°F ambient temperature. The lifetimes are solely meant to be a guide for expected LED degradation and not a warranty or predictive of their actual life, which can be affected by ambient temperatures and other factors.

SPECIFICATIONS

SPECIFICATIONS

Dimensions (in)

25.2 x 12.7 x 3.3

Units/carton

Dimensions (in)

1

Net Weight

14.5 lbs

Environmental Rating

25.2 x 12.7 x 3.3

Units/carton

1

Net Weight

Wet

16 lbs

Environmental Rating

Wet

ORDERING INFORMATION Example: QL2-1-UNVL-4-5M-52-0

QL2

1

52

Series

Variant Input Voltage # of Qubes

Light Dist Pattern

Color Temp

Options

QL2

1

52

0 0-10V Dimming

UNVL 120-277

3

5M 5 Medium

UNVH* 277-480

4

2M* 2 Medium

5200K

1 Photocell Socket 2 **DynaDimmer 3 **Photocell Socket & DynaDimmer

* Not DesignLights Conortium qualified ** Note: Options 2 and 3 not available with UNVH Input Voltage

Specifications and dimensions subject to change without notice.

Horizontal mounting only

DATASHEET 05.06.2014


QubeLot2 INSTALLATION INSTRUCTIONS The installation must only be performed by a licensed electrician. To prevent death, injury or damage to property, this product must be installed in accordance to National Electrical Code (NFPA70) in the US or Canadian Electrical Code (CSA22.1) in Canada. Disconnect power before installing the product or servicing it. Wait until fixture has cooled down before installing or servicing the fixture.

1. Turn off power to light pole at circuit breaker. 2. Drill necessary holes into pole for fixture mounting (FIG 1). 3. Remove pole cap and lower nut plate inside of pole until threaded holes align with proper moutning holes. 4. Assemble threaded rods into nut plate and slide on gaskets and spacer block (FIG 2). 5. Affix back housing to pole using washer plate, lock washers and nuts (FIG 3). 6. Hang light engine assembly onto back housing (FIG 4). 7. Make connections as required by the wiring diagram. 8. Rotate light engine assembly to closed position and secure using captive screws.

FIG 1

FIG 2

FIG 3

FIG 4 #44-000016 UPDATED 02.06.2013

Specifications and dimensions subject to change without notice.

US LED

|

6807 PORTWEST DR

|

HOUSTON, TX 77024

|

T 866 972 9191

|

F 713 972 9393

|

info@usled.com

|

www.usled.com


QubeLot2 INSTALLATION INSTRUCTIONS WIRING DIAGRAMS LEGEND *VERIFY CORRECT POWER SUPPLY

.

FACTORY INSTALLED

.

.

FIELD INSTALL

OPTION 1

OPTION 2 - PHOTOCELL

#44-000016 UPDATED 02.06.2013

Specifications and dimensions subject to change without notice.

US LED

|

6807 PORTWEST DR

|

HOUSTON, TX 77024

|

T 866 972 9191

|

F 713 972 9393

|

info@usled.com

|

www.usled.com


QubeLot2 INSTALLATION INSTRUCTIONS WIRING DIAGRAMS LEGEND *VERIFY CORRECT POWER SUPPLY

.

FACTORY INSTALLED

.

.

FIELD INSTALL

OPTION 3 - DYNADIMMER

OPTION 4 - PHOTOCELL AND DYNADIMMER

#44-000016 UPDATED 02.06.2013

Specifications and dimensions subject to change without notice.

US LED

|

6807 PORTWEST DR

|

HOUSTON, TX 77024

|

T 866 972 9191

|

F 713 972 9393

|

info@usled.com

|

www.usled.com


iBright™ LED Vapor Proof Fixture

S

Model VP4FT4K-00 VP4FT5K-00 VP5FT4K-00 VP5FT5K-00

Product Description

Performance Summary

iBright™ LED Vapor Proof Fixture supports for pendant, ceiling and wall mounting solutions which is more flexible and easy-to-install. It has imaginative appearance and impressive uniformity and available in 4ft and 5ft. The 5ft fixture can reach 5500 lm with only 60W power consumption which is equal to 2 to 3 pcs LED tubes. iBright™ LED Vapor Proof Fixture is widely used for ambient lighting application like parking lots, gas stations, tunnels, warehouses and more.

www.atgelectronics.com

Toll free: 877-461-5333

Length: 4ft, 5ft Power consumption: 50W, 60W Luminous efficacy: Typ. 85+ lm/W Lumens: 4300 lm, 5500 lm CCT: 4000 K, 5000 K CRI: >80 PF>0.92/ THD<20%

E-mail: sales@atgelectronics.com


Ordering Information Typical Order Example: VP4FT5K-00 SERIES

Length

CCT

VP=Vapor Proof

4FT 5FT

4K=4000K 5K=5000K

OPTIONS 00=Standard SN=Sensor EM=Emergency DM=Dimming

Product Specifications CONSTRUCTION & MATERIALS Type Dimension Housing Lens Type

4 FT 1265*129*88 mm (49.80*5.08*3.46 inch) PC Frosted

5 FT 1563*129*88 mm (61.54*5.08*3.46 inch)

ENVIRONMENTAL SYSTEM Work Environment Operating Temperature

Indoor use -30℃~40℃

OPTICAL SYSTEM Type Luminous Flux Luminous Efficacy Color Temperature CRI Lumen maintenance at 6000h

4 FT 4300 lm Typ. 85+ lm/W 4000 K, 5000 K 80 98.28%

5 FT 5500 lm

4 FT 50 W 100-277 VAC >0.92 <20%

5 FT 60 W

ELECTRICAL SYSTEM Type Power Consumption Input Voltage Power Factor THD

50/60 HZ

REGULATORY & VOLUNTARY QUALIFICATIONS DLC pending ETL/cETL pending UL/cUL, and CE certified external driver

www.atgelectronics.com

Toll free: 877-461-5333

E-mail: sales@atgelectronics.com


70W 2x4 LED Panel SPECIFICATIONS: WATTAGE: MODEL #: DLC #: UL & CUL: CERTIFICATIONS: LUMENS OUTPUT (IES): EFFICACY (IES): VOLTAGE: POWER FACTOR: KELVIN (CCT): BEAM ANGLE (DEGREE): CRI: LIFE SPAN (HOURS): DIMMING COMPATIBLE: LENGTH OF WARRANTY (YEARS): FIXTURE MATERIAL: DIMENSIONS (L X W X H) WEIGHT: MOUNTING OPTIONS: WORKING ENVIRONMENT: SUGGESTED REPLACEMENT FOR: PERCENTAGE OF WATTAGE SAVED:

70W LP1206-70W-40KD LP1206-70W-50KD LP1206-04 E466848 UL, CuL, FCC, CE, RoHS, DLC 6000LM 100.3 LM/W AC100-277V, AC347-480V (optional) 0.95 4000/5000 120°, 85°/135° Degrees 82 50,000 Hours Yes, O-10V Dimming 5 Years Standard Aluminum 600x1200x11mm (23.80x47.80x0.43 in) 9.9 kg (21.8 lbs) Surface Mount, Suspended/Hanging -25°C to 40°C (-20°F to 120°F) 200W 75%

Built-in

Suspended/Hanging

Features: Unique design model with ultra-thickness <11mm. Driver protected by junction box fixed on back of panel for more safety and stability. Four corner protected by electroplating PC cover. Output lead wire screwed by connecter allowing easy wiring and installation. Stable driver with UL and DLC approved.

Surface Mount

Applications: Used for indoor commercial and home lighting such as hospital, offices, residential restaurants, retail stores, art galleries, museums, and hotels.

Contact Brite Energy Solutions - Tom Knoblock 1-844-533-2897 Toll Free

-


)

ILTCaseLight CaseLight is DLC Listed! ILTCaseLight ILTCaseLight

LED Refrigerated Case Lighting System LED Refrigerated Case Lighting System LED Refrigerated Case Lighting System Make Make Your Your Prepared Prepared Foods Foods POP POP With With CaseLight™ LED Modules! Make Your Prepared Foods POP CaseLight™ LED Modules! Make Your Prepared Foods POP With With CaseLight™ LED Modules! Easily Replace Existing Cooler/Freezer Display CaseLight™ LED Modules! Easily Replace Existing Cooler/Freezer Display

CaseLight CaseLight is is DLC DLC Listed! Listed! CaseLight is DLC Listed!

EasilyFluorescent Replace Existing Case LightsCooler/Freezer Display • Easily Replace Existing Cooler/Freezer Display Case Case Fluorescent Lights EasilyUsing Replace Easy Mounting TEKExisting ScrewsCooler/Freezer or VHB Foam Display Fluorescent Lights Easy Mounting Using TEK Screws or VHB Foam Case Fluorescent Tape When Space is LimitedLights Tape When Space is Limited Easy Mounting Using TEK Screws or VHB Foam • Easy Mounting Using TEK Screws or VHB Foam Tape No Need to Empty Shelves! No Need to Empty Shelves! Energy When Space is Limited Tape When Space is Limited Lower Bills and No Burned Out Bulbs! Lower Energy Bills and No Burned Out Bulbs! NoLife Need to Empty Shelves! Long Fixture – YEARS vs. Weeks/Months • No Need to Empty Shelves! Long Fixture Life – YEARS vs. Weeks/Months Lower Energy BillsWarranty and No Burned Out Bulbs! Low Maintenance – 5 Year on CaseLight Low Maintenance – 5 Year Warranty on CaseLight • Lower Energy Bills and No Burned Out Bulbs! Long Fixture Life – YEARS vs. Weeks/Months Modules & Power Supplies Modules & Power Supplies Low Maintenance 5 Year Warranty on CaseLight DLC Listed – Eligible for ALL–Rebates • Long Fixture Life – YEARS vs. Weeks/Months DLC Listed – Eligible for ALL Rebates Modules &Made Power CaseLight Modules inSupplies the USA CaseLight Modules Made in the USA DLC Listed – Eligible for ALL Rebates • Low Maintenance – 5 Year Warranty CaseLight Modules Made in the USA Improving on the success of ILT's previous on CaseLight Modules & Power Supplies Improving on the success of ILT's previous CaseLight modules for refrigerated/freezer CaseLight modules for refrigerated/freezer DLC Listed – Eligible for ALL Rebates Improving on the success of ILT's previous display• cases, ILT's new, more efficient CaseLight display ILT'slower new, morefor efficient CaseLight CaseLight modules refrigerated/freezer modulecases, has even power consumption and module has even lower power consumption and • CaseLight Modules Made in the USA display cases,performance ILT's new, more efficient CaseLight higher overall optical for your higher overall optical performance for your moduleand hasfreezers. even lower consumption and reach-in coolers Forpower Retrofit or New reach-in coolers and freezers.ofFor Retrofit or CaseLight New Improving onoverall the success ILT's previous performance for your modules cases, ILT higher CaseLight canoptical be installed easily and cases, ILT CaseLight can bedisplay installed easily and for refrigerated/freezer cases, ILT's new, more efficient reach-in coolers and freezers. For Retrofit or New cost-effectively. cost-effectively. CaseLight module has even power consumption and cases, ILT CaseLight canlower be installed easily and highercost-effectively. overall optical performance your LED-based CaseLight modules provide for all of thereach-in coolers LED-based CaseLight modules provide all of the advantages of LED-based lighting including and freezers. For Retrofit or New cases, ILT CaseLight can be advantages of LED-based lighting including LED-based CaseLight modules provide all of the much longer life (greater than 50,000 hours), installed and cost-effectively. much longereasily life (greater than 50,000 hours), advantages of LED-basedand lighting much lower energy consumption muchincluding much lower energy consumption and much much longer life (greater than 50,000 better lighting characteristics – brighter light LED-based modules provide all ofhours), the advantages better lightingCaseLight characteristics – brighter light much lower energy consumption focused on the merchandise. Plus all of ILT'sand much of LED-based lighting including much longer life (greater focused on the merchandise. Plus qualifying all of better lighting characteristics –ILT's brighter CaseLight modules are DLC listed for light CaseLight modules are DLC listed qualifying for than 50,000 hours), lower energy and on themuch merchandise. Plus allconsumption of ILT's maximumfocused utility rebates. maximum utility rebates. much CaseLight better lighting characteristics – brighter lightforfocused modules are DLC listed qualifying on themaximum merchandise. all of ILT's CaseLight modules are utilityPlus rebates. DLC listed qualifying for maximum utility rebates. 40-Plus Years of ILT Lighting Experience 40-PlusGoes Years of ILT Lighting Experience Into Every CaseLight! Goes Into Every CaseLight! 40-Plus Years of ILT Lighting Experience 45-Plus Years of ILT Lighting Experience Goes Into Every CaseLight! Goes Into Every CaseLight!

ILTINNOVATIONS ILTINNOVATIONS ILTINNOVATIONS

I n te r n at i o n a l L i g h t Te c h n o l o g i e s, Pe a b o d y, M A ( U S A ) • 4 0 Y e a r s o f L i g h t i n g E x p e r i e n c e – W e K n o w L i g h t ! 45 ( U S A ) •I n4te0 rYneat a riso no af lLLiigghht ti nTe g cEhx np oe rl oi egni cees, –PeWa be oKdny,o wM LAi g( U h tS!A ) • 4 0 Y e a r s o f L i g h t i n g E x p e r i e n c e – W e K n o w L i g h t ! S I n te r n at i o n a l L i g h t Te c h n o l o g i e s, Pe a b o d y, M A ( U S A ) • 4 0 Y e a r s o f L i g h t i n g E x p e r i e n c e – W e K n o w L i g h


ILT48-BAO-W40LE ILT48-BAO-W40RE

CaseLight, 48”, Brite Anodize, Left unit CaseLight, 48”, Brite Anodize, Right unit

Color Temp. (K)

Lumens Energy (Watts) Life (Hours) CRI (Typical)

ILT48-BAO-W35CE * ILT48-BA0-W50CE ILT48-BAO-W50CE ILT48-BAO-W35LE * ILT48-BA0-W50LE ILT48-BAO-W50LE Part Number * ILT48-BA0-W50RE ILT48-BAO-W50RE ILT48-BAO-W35RE

CaseLight, 48”,48”, Brite Anodize, 3500 CaseLight, Brite Anodize,Center Centerunit unit 5000 CaseLight, 48”,48”, Brite Anodize, 3500 CaseLight, Brite Anodize,Left Leftunit unit 5000 Color Temp. (K) Description CaseLight, 48”, Brite Anodize, Right unit 5000 CaseLight, 48”, Brite Anodize, Right unit 3500

825750 500005000087 1200 15 15 85 88 412375 7.58 8 500005000087 600 85 88 Lumens Life (Hours) CRI (Typical) 412375 Energy 50000 87 600 7.58(Watts) 8 50000 85 88

Description

ILT48-BAO-W50CE ILT48-BAO-W40CE * ILT48-BA0-W40CE

ILT60-BAO-W50CE ILT48-BAO-W50LE ILT48-BAO-W40LE * ILT48-BA0-W40LE ILT60-BAO-W50LE ILT48-BAO-W50RE ILT48-BAO-W40RE * ILT48-BA0-W40RE ILT60-BAO-W50RE ILT48-BAO-W40CE ILT48-BAO-W35CE * ILT48-BA0-W35CE

CaseLight, 48”, Brite Anodize, Center unit

CaseLight, 60”,48”, Brite Anodize, unit CaseLight, Brite Anodize,Center Left unit CaseLight, 60”,48”, Brite Anodize, unitunit CaseLight, Brite Anodize,Left Right CaseLight, 60”, Brite Anodize, Right unit

CaseLight, 48”, Brite Anodize, Center unit

ILT48-BAO-W35LE CaseLight, Brite Anodize, unit ILT60-BAO-W50LE 60”, Color DescriptionWatts Temp. LeftLumens Lumens CRI 48”, Recommended ILT48-BAO-W35RE CaseLight, 48”, Brite Anodize, Right ILT60-BAO-W50RE (K) (W) CaseLight, 60”,60”, ILT60-BAO-W35CE BriteApplications Anodize, Center unit unit W35LH Horizontal CaseLight, 48”, 3500 1135 1135 26.6 90 Fresh meats ILT60-BAO-W35LE CaseLight, 60”, Brite Anodize, Left unit ILT60-BAO-W50CE CaseLight, 60”, Brite Anodize, Center unit ILT60-BAO-W40CE Brite Anodize, Left configuration. ILT60-BAO-W35RE CaseLight, 60”,60”, Brite Anodize, Right unit ILT60-BAO-W50LE Brite Anodize, ILT60-BAO-W40LE W35RH1135 Horizontal CaseLight, 48”, CaseLight, 3500 1135 26.6 90 Fresh meats Left unit ILT60-BAO-W50RE CaseLight, 60”, Brite Anodize, Right unit ILT60-BAO-W40RE Brite Anodize, Right configuration. ILT70-BAO-W50CE CaseLight, Anodize, Center1135 unit W40LH 48”, 4000 dairy 1135Horizontal CaseLight, 26.6 90 70”, BriteProduce, ILT60-BAO-W40CE CaseLight, 60”, Brite Anodize, Center ILT60-BAO-W35CE Brite Anodize, Left configuration. ILT70-BAO-W50LE CaseLight, 70”, Brite Anodize, Left unitunit ILT60-BAO-W40LE Anodize, ILT60-BAO-W35LE W40RH1135 Horizontal CaseLight, 48”, CaseLight, 4000 1135 26.6 90 60”, Brite dairyLeft unit ILT70-BAO-W50RE CaseLight, 70”, BriteProduce, Anodize, Right unit Brite Anodize, Right configuration. ILT60-BAO-W40RE CaseLight, 60”, Brite Anodize, Right unit ILT60-BAO-W35RE W50LH1200Horizontal CaseLight, 48”, 5000 food 1200 26.6 87 Frozen Brite Anodize, Left configuration. ILT70-BAO-W40CE CaseLight, 70”, Brite Anodize, Center unit ILT60-BAO-W35CE CaseLight, 60”, Brite Anodize, Center unit ILT70-BAO-W50CE 70”, ILT60-BAO-W35LE CaseLight, Brite Anodize, Leftunit unit ILT70-BAO-W50LE 70”, W50RH Horizontal CaseLight, 48”, 5000 1200 1200 26.6 87 70”,60”, Frozen foodLeft ILT70-BAO-W40LE CaseLight, Brite Anodize, Brite Anodize, Right configuration. ILT60-BAO-W35RE CaseLight, Brite Anodize,Right Rightunit unit ILT70-BAO-W50RE 70”, ILT70-BAO-W40RE CaseLight, 70”,60”, Brite Anodize, W35LH1535Horizontal CaseLight, 70”, 3500meats 1535 35.9 90 Fresh Brite Anodize, Left configuration. ILT70-BAO-W50CE CaseLight, 70”, Brite Anodize, Center unit ILT70-BAO-W40CE ILT70-BAO-W35CE CaseLight, Brite Anodize, unit W35RH Horizontal CaseLight, 70”, 3500 1535 1535 35.9 90 70”,70”, Fresh meatsCenter ILT70-BAO-W50LE CaseLight, Brite Anodize, Left unit ILT70-BAO-W40LE Brite Anodize, Right configuration. ILT70-BAO-W50RE CaseLight, Brite Anodize,Left Right ILT70-BAO-W40RE ILT70-BAO-W35LE CaseLight, 70”,70”, Brite Anodize, unitunit W40LH Horizontal CaseLight, 70”, 4000 1535 1535 35.9 90 Produce, dairy ILT70-BAO-W35RE CaseLight, 70”, Brite Anodize, Right unit Brite Anodize, Left configuration. ILT70-BAO-W40CE CaseLight, 70”, Brite Anodize, Center unit ILT70-BAO-W35CE W40RH1535 Horizontal CaseLight, 70”, 4000 1535 35.9 90 70”, Brite Produce, dairyLeft unit ILT70-BAO-W40LE CaseLight, Anodize, ILT70-BAO-W35LE Brite Anodize, Right configuration. ILT70-BAO-W40RE CaseLight, 70”, Brite Anodize, Right unit ILT70-BAO-W35RE W50LH1700 Horizontal CaseLight, 70”, 5000 food 1700 35.9 87 Frozen * Not DLC Listed Brite Anodize, Left configuration. ILT70-BAO-W35CE CaseLight, 70”, Brite Anodize, Center unit W50RH1700 Horizontal CaseLight, 70”, CaseLight, 5000 1700 35.9 87 70”, Brite Frozen food Left unit ILT70-BAO-W35LE Anodize, Power Supplies Brite Anodize, Right configuration. ILT70-BAO-W35RE CaseLight, 70”, Brite Anodize, Right unit ILT-LPF-40-24 -24 60 Watt, UL 2,Class 2 Powers Powerinput, Supply 4VDC output up to24VDC 2100-277VAC – 70” units input, 24VDC output 40 Watt, UL Class 100-277VAC output 24 output 40 Watt, UL Class 2 Powers Power Supply 4VDC up to 2100-277VAC – 48” units input, 24VDC output ILT-CEN-60-24 60 Watt, UL Class 2, 100-277VAC input, 24VDC output 0UNVA 2 Power input, 24VDC output DC output 100W, UL Class Powers up toSupply 3 – 70”120-277VAC units or 4 – 48” units 1.65" C

1.17"

US

I

n I t n et re nr na at t i i o o n n a

825 750 1160 1100 412 375 580 412 375550 580

15 7.58 20 7.58 10

50000 87 88 85 50000 50000 87 88 85 50000 50000 87 88 85

4000 3500 4000 3500 4000 4000 3500

750 1160 375 580 1000 375 580

15 7.58 20 7.58

50000 88 85 50000 88 50000 85 50000 88 85

550

4000 4000 3500 5000

500 750500 1100 1600

10

50000

88 88

87 87 87

88 50000 88 500005000088 87 85 88

10 15 10 20

3500 375 8 50000 88 5000 550 87 800 10 85 Watts CRI Recommended 3500 375 8 50000 88 5000 550 800 (W) 3500 1280 10Applications 20 500008785 88 26.6 90640 Fresh 3500 10 meats 500005000087 88 5000 1100 4000 1000 88 1547 20 85 3500 640 10 10 5000087 5000 550 50000 4000 500 88 773 85 88 26.6 90 Fresh meats 5000 550 50000 87 4000 500 88 773 10 85 5000 1280 25 dairy 50000 87 26.6 90 Produce, caselight brochure for IR:Layout 1 6/23/11 10:57 AM Page 1 4000 1000 50000 88 3500 1280 1547 20 85 5000 640 13 50000 87 4000 500 88 3500 640 773 10Produce, dairy 50000 85 26.6 90 5000 640 10 13 500008885 87 4000 500 50000 3500 640 773 Part Number Description Color Temp. (K) Lumens Energy (Watts) 26.6 87 Frozen food ILT60-BAO-W50CE CaseLight, 60”, Brite Anodize, Center unit 5000 1100 4000 1175 25 3500 1280 20 25 5000050000 88 5000 87 2000 85 102088 ILT60-BAO-W50LE CaseLight, 60”, Brite Anodize, Left unit 5000 550 3500 640 10 5000 13Frozen 87 1000 12.5 85 1088 26.6 87587 ILT60-BAO-W50RE CaseLight, 60”, Brite Anodize, Right unitfood5000 50000 550 88 4000 13 50000 3500 640587 12.5 10 500005000088 5000 13 87 1000 85 88 4000 ILT60-BAO-W40CE CaseLight, 60”, Brite Anodize,13 Center unit 4000 1000 20 35.9 90 Fresh meats ILT60-BAO-W40LE CaseLight, 60”, Brite Anodize, Left unit 4000 500 10 ILT60-BAO-W40RE CaseLight, 5000 1280 4000 117560”, Brite Anodize, 88 1940 25 Right unit 4000 50000 500 87 85 10 3500 1175 25 500008885 2088 35.9 90 60”, Brite Anodize, meats 5000 640 13Fresh 4000 587 970 12.5 ILT60-BAO-W35CE CaseLight, Center unit 3500 500001000 87 ILT60-BAO-W35LE CaseLight, 60”, Brite Anodize, Left unit 3500 50000 500 87 5000 640 13 13 4000 587587 88 970 12.5 85 1088 3500 50000 ILT60-BAO-W35RE CaseLight, 60”, Brite Anodize, Right unit dairy 3500 500 10 35.9 90 Produce, 3500 587 13 50000 88 4000 117570”, Brite Anodize, ILT70-BAO-W50CE CaseLight, 3500 1940 25 Center unit 5000 500001280 88 85 27 ILT70-BAO-W50LE CaseLight, Left unit dairy 5000 640 35.9 90 70”, Brite Anodize, 4000 587 13Produce, 50000 640 88 3500 970 12.5 85 1414 ILT70-BAO-W50RE CaseLight, 70”, Brite Anodize, Right unit 5000 4000 587 13 50000 88 3500 970 12.5 85 35.9 Frozen food ILT-CEN-60-24 Power 87 Supply, 100-277VAC in, 24VDC out, powers up to 3 – 60”Center units 3500 1175 25 50000 88 35.9 87 3500 587 13 Frozen food 50000 88 2.18" 3500 587 13 50000 88 Powers up to 2 – 70” units Powers up to 2 – 48” units Powers up to 3 – 70” units or 4 – 48” units

Life (Hours) 50000 50000 50000 50000 50000 50000 50000 50000 50000 50000 50000 50000 -

1.65"

ISO 9001:2008 ISO 9001:2008 10 Technology Drive, Peabody, MA 01960 10978-818-6180 Technology Drive,978-818-6181 Peabody, MA 01960 fax 978-818-6180 978-818-6181 fax intl-lighttech.com intl-lighttech.com

1.17"

ILT-D24V100UNVA 100W, UL Class 2, 120-277VAC input, 24VDC output

50000 50000

1.17"

CaseLight, 60”, Brite Anodize, Center unit CaseLight, 48”, Brite Anodize, Right unit CaseLight, 60”, Brite Anodize, Left unit CaseLight, 60”,48”, Brite Anodize, CaseLight, Brite Anodize,Right Centerunit unit 60”,

8 8

5000 4000 5000 5000 4000 5000 5000 4000

5000

Light brochure_Layout 1 9/18/12 4:06 PM Page 248”, Brite Anodize, Left unit ILT48-BAO-W40LE CaseLight, ILT48-BAO-W35LE * ILT48-BA0-W35LE

ILT60-BAO-W40CE ILT48-BAO-W40RE ILT48-BAO-W35RE * ILT48-BA0-W35RE ILT60-BAO-W40LE ILT60-BAO-W40RE ILT48-BAO-W35CE ILT60-BAO-W50CE

375 375

1.17"

Part Number

4000 4000

ISO 9001:2008 10 Technology Drive, Peabody, MA 01960 a 978-818-6180 l L i g978-818-6181 h t fax T intl-lighttech.com

l

L

i

g

h

t

T E E C C H H N NO

OL

OL

GO

IG E

I SE

S


Installation Instructions Note – Wiring and mounting instructions are applicable for both center and end units Model Numbers – Example ILT60-BAO-W50CE ILTAABAOWBB CE (AA=Length-inches) (Brite Anodize (BB=color temp) (C=Configuration; E=External Power finish) Supply) ILT48 (48”)

35 (3500K)

CE (Center, External Power Supply)

ILT60 (60”)

40 (4000K)

LE (Left, External Power Supply)

ILT70 (70”)

50 (5000K)

RE (Right, External Power Supply)

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. B. Before installing, servicing or cleaning unit, switch power off at the service panel and follow appropriate lock out / tag out safety procedures. FOR YOUR SAFETY: Read and observe all CAUTIONS and WARNINGS shown throughout these instructions. While performing installations described, gloves, safety glasses or goggles should be worn. PREPARE ELECTRICAL WIRING: A. Electrical Requirements – This fixture must be powered by a Meanwell, 60W, 24VDC power supply, model CEN-60-24, ILT part number ILT-CEN-60-24, connected to a properly grounded branch circuit, protected by a circuit breaker. B. Grounding Instructions – This power supply must be connected to a grounded metal, permanent wiring system. C. Strain Relief Requirements – This fixture is equipped with a cord but no attachment plug. Therefore, the installer must include a strain relief sized properly for the cable and opening in the junction box it is attaching to. An example is the Heyco Products strain relief, part number 1150, or equivalent if routing wire into a junction box or through an access hole.

CI-101 Rev. A

Page 1

International Light Technolgies 978-818-6180 Brite Energy Solutions 308-367-4542

4/25/2012


TOOLS NEEDED: - Wire connectors - Wire cutters - Gloves - Tape measure - Wire stripper - Safety glasses - Center punch - Power drill - Screwdriver - #6 x 1 1/2” self-tapping screws

Prepare for Mounting Light Fixture to Mullion – using #6 x 1 1/2” self-tapping screws CAUTION – Turn off power to the mullion lighting system before removing any covers. - Measure the total length of the mullion to determine which model/length unit to install. Center the fixture vertically on the mullion. Mark the top and bottom of the fixture. - Measure the total width of the mullion and mark a vertical line, ½ the total width near the top, 6” from the top, 6” from the bottom. - Mark a horizontal line 6” down from the top of the fixture. Mark a horizontal line 6” from the bottom of the fixture. CAUTION – Prior to installing screws, make sure that there are no existing components inside the mullion in the areas to be drilled. Do not drill through “DO NOT DRILL” label. - Use power drill and screw bit and install 4, #6 x 1 1/2” self-tapping screws through the center indent of the fixture. Install 2-3 screws, one 6” from top, one 6” from bottom and one in the center if necessary. NOTE – Starting the screws into the fixture with the fixture outside the cooler may make it easier for installation. Screws can then be fully inserted into mullion while holding fixture in place.

Alternate Mounting Method High quality VHB-type foam tape may also be used to mount the fixtures. − Thoroughly clean the back of the fixture and the mullion surface. − Using 1/2”-3/4” wide VHB tape, apply tap to back surface of fixture to within 3” of top and bottom of fixture. CI-101 Rev. A

Page 2

10 Technology Dr., Peabody, MA 01960

4/25/2012 978-818-6180 978-818-6181 fax


− Dry fit fixture to mullion. Once fit is confirmed, peel release paper, align fixture and press against mullion for entire length of fixture.

Connect Wiring from Fixture CAUTION – Ensure that all connection points are sealed for damp location using the appropriate method per the NEC or local electrical code. -

Cut the fixture cable to the appropriate length to terminate to DC power at the Power Supply. Where necessary, insert the proper strain relief on the cable and secure to hole in mullion or junction box. Strip the cable jacket and then strip the individual two wires. Attach the Black wire to the Black wire of the power supply using twist-on wire connector. Attach the Red wire to the Red wire of the power supply using twist-on wire connector.

Connect Wiring to Power Supply CAUTION – Wiring to high voltage side of power supply to be accomplished by certified electrician in accordance with NEC or local electrical code.

Trouble-shooting and Maintenance Instructions CAUTION – Turn off power to the mullion lighting system before removing any covers. The following items can be replaced in the field: - 60W Power Supplies - LED flex strips (access to end of unit required)

TROUBLE-SHOOTING -

If an entire strip of LEDs are not lighted (one of the two strips for a center unit or the one strip of an end unit), either there is a wiring problem to that strip or the LED driver is defective. Check wiring connections to the unit at the driver. If the connections look OK, proceed to “Replacement of LED Driver”. If both LED strips are not lighted on a center unit or the single strip isn’t lighted on an end-unit, it is possible that power to the unit has been interrupted. Confirm that the cable to the unit is wired properly and securely to the DC power source.

Replacement of LED Flex Strip - Remove the 2, #4 screws securing the end-cap where the cable exits the unit. - Slide out the lens on the side of the defective LED flex strip. - Cut the two wires from the defective LED flex strip about 6” from the end of the strip. CI-101 Rev. A

Page 3

10 Technology Dr., Peabody, MA 01960

4/25/2012 978-818-6180 978-818-6181 fax


-

Remove the defective LED flex strip by peeling away from the housing. Install the new LED flex strip by peeling the release tape and sticking to the housing. Start at wired end positioning start of strip about 1� from end of housing. Continue down the full strip, pressing in between components to insure a good bond. Connect Red and Black wires to the wires previously cut. Attach using twist on wire nuts. Push the wire nuts inside extrusion. Slide in lens which was previously removed. Re-attach end-caps with 2 #4-40 screws previously removed.

-

Fixture Cleaning Instructions -

The lens and aluminum housing should be cleaned periodically with a mild liquid dish detergent. Do not use chemical cleaners on the lens. Keep the outside clean. Wipe with a clean cloth lightly dampened with mild liquid dish detergent. Dry with a clean, soft cloth. Do not use scouring pads, powdered cleaners, bleach or cleaners containing bleach because these products can scratch and damage the finish.

-

Door Configurations The ILT-CEN-60-24, 60W, 24VDC power supply can power up to 3 Center units. Here are three typical door configurations and the number of power supplies required for each. # of Doors # of Center # of End Units Units

# of Power Supplies

Notes

3

2

2

1

4

3

2

2

2 Centers-1 End; 1 Center-1 End

5

4

2

2

2 Centers-1 End per P.S.

3

2 Centers-1 End per P.S. It is possible to wire 2 Centers and 2 Ends on 1 P.S.

6

5

CI-101 Rev. A

2

Page 4

10 Technology Dr., Peabody, MA 01960

4/25/2012 978-818-6180 978-818-6181 fax


4” LED COMMERCIAL RECESSED DOWNLIGHT RETROFITS The commercial-grade LED Recessed Downlight Retrofit is supplied with a quick connect-case and conduit to make an easy connection to an existing recessed fixture frame junction box.

PROJECT NAME

CATALOG NUMBER

NOTES

FIXTURE TYPE

FEATURES: • Universal voltage (120-277) • Mounts into existing recessed frame • Supplied with optional retaining clips if existing frame does not have adequate friction springs to secure reflector • cETL listed for damp location use • CRI: > 85 • PF: >.9 • A wide variety of CCTs available: 3000K and 4000K come standard 2700K and 5000K (contact MaxLite for quotations) • Five year limited warranty • Dimmable to 5% (120v only)

CONSTRUCTION: • Supplied with a heavy gauge anodized aluminum reflector in a haze finish Scan the QR code with a smartphone to view the installation video or visit the following link: http://bit.ly/ledcrdr

• External driver for easy retrofit and maintenance • Power supply features integral thermal protection

Watts

Order Number

Model Number

Fluorescent Equivalent

Lumens

Lamp Life (Hrs.)

CCT

14

73567

RR41530W

1 X 26W PL

785

50,000

3000

14

73568

RR41540W

1 X 26W PL

875

50,000

4000

26

72605

RR42630W

2 X 18W PL

1340

50,000

3000

26

72606

RR42640W

2 X 18W PL

1515

50,000

4000

Accessories Order Number

Model Number

Description

74086

RR4-BNRING

4” BRUSHED NICKEL TRIM RING CONSULTING – SPECIFYING

®

2014

RoHS COMPLIANT

FINALIST

MaxLite®: 1-800-555-5629 | Fax: 973-244-7333 | Web: www.maxlite.com | E-mail: info@maxlite.com

Revised: 11-19-14

MAX13155

Luminaire Ordering Information:


4” LED COMMERCIAL RECESSED DOWNLIGHT RETROFITS REFLECTOR

STANDARD TRIM RING

4.55” 3.75” .27” 6.15”

4.7”

PRODUCT FEATURES RETAINING CLIPS

EXTERNAL DRIVER

Retaining clips are supplied for situations where the existing recessed frame does not have pre-installed clips to secure the reflector.

OVERALL DIMENSIONS

COMPATIBLE DIMMERS: 8.79”

MAKE

DIMMER MODEL

Lutron

CTCL-153PD*

3.24”

Lutron

DVCL-153PL*

3.75”

Lutron

CTELV-303P

Lutron

DVELV-303P

Lutron

LGCL-153PL*

Leviton

IPI10

6.1”

1.16”

16.65”

4.9”

44.48

* Dimming control should be adjusted to 5% minimum light output level in order to avoid flickering. Please consult dimming control instruction manual for specific procedure. CONSULTING – SPECIFYING

®

2014

RoHS COMPLIANT

FINALIST

MaxLite®: 1-800-555-5629 | Fax: 973-244-7333 | Web: www.maxlite.com | E-mail: info@maxlite.com

Revised: 11-19-14


4” LED COMMERCIAL RECESSED DOWNLIGHT RETROFITS RR42630W 180

INTENSITY (CANDLEPOWER) SUMMARY 150

120

90

300 60 600

ANGLE 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90

MEAN CP 870 876 911 991 1096 1089 824 407 258 178 117 63 22 9 4 1 0 0 0

LUMENS 86 286 477 281

ZONAL LUMENS AND PERCENTAGES ZONE 0-30 0-40 0-60 0-90 40-90 60-90 90-180 0-180

LUMENS 849 1130 1326 1338 207 12 0 1338

% LUMINAIRE 63.48 84.51 99.13 100.00 15.49 0.87 0.00 100.00

139 LUMINANCE SUMMARY CD./SQ.M.

57

ANGLE 45 55 65 75 85

10 2 0

MEAN CD/SQ M 31161 13602 2623 606 0

900

0

30

RR42640W 180

INTENSITY (CANDLEPOWER) SUMMARY 150

120

90

350 60 700

ANGLE 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90

MEAN CP 1008 1015 1054 1155 1295 1290 966 426 262 180 118 64 23 10 4 2 0 0 0

LUMENS 100 334 564 306

ZONAL LUMENS AND PERCENTAGES ZONE 0-30 0-40 0-60 0-90 40-90 60-90 90-180 0-180

LUMENS 998 1304 1503 1516 212 13 0 1516

% LUMINAIRE 65.80 86.01 99.15 100.00 13.99 0.85 0.00 100.00

141 LUMINANCE SUMMARY CD./SQ.M.

59

ANGLE 45 55 65 75

11 2 0

MEAN CD/SQ M 31592 13842 2889 750

1050

0

30 CONSULTING – SPECIFYING

®

2014

RoHS COMPLIANT

FINALIST

MaxLite®: 1-800-555-5629 | Fax: 973-244-7333 | Web: www.maxlite.com | E-mail: info@maxlite.com

Revised: 11-19-14


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.