eLucent™ WP Series LED Wall Pack WPFC Series WP00 Series Dark Sky Compliant
WPDS Series Dark Sky Compliant
WWPW
Family Model WPFC40 WPFC60 WPFC90
WP0040 WP0060 WP0090
Product Description
W
eLucent™ WP Series LED Wall pack is designed for applications that require lighting with a long life and low maintenance requirement.
WPFC40
With effective thermal management, corrosion-resistant, and die-cast aluminum enclosure with an architectural dark brown finish, eLucent™ WP Series LED Wall provides glare free, uniform illumination while providing a safe and comfortable visual experience. eLucent™ WP Series LED Wall pack adopts high luminous efficacy SMD LEDs. They are available in 40 watts, 60 watts and 90watts. With superior 60%-90% energy savings, compared to halogen lamp or a metal halide lamp, eLucent™ WP90 achieves a superlative luminous flux of 8500 lm and only consumes approximate 90 watts.
W WPFC60 & WPFC90
High lumen output, energy-efficient optical control and easy universal installation features confirm the eLucent™ WP Series LED Wall as the absolute choice for indoor and outdoor illumination.
Performance Summary
W WP0040
Power consumption 40W
60W
90W
Lumens
4000 lm
6000 lm
8500 lm
PF/THD
>0.9/<15%
>0.9/<20%
>0.9/<20%
CCT: 5700 K Color Accuracy: CRI 85, R9>20 L70 lifetime: 130,000h W WP0060 & WP0090
www.atgelectronics.com
Toll free: 877-461-5333
E-mail: sales@atgelectronics.com
Ordering Information Typical Order Example: WPFC60HU570000 SERIES
HOUSING
WATT
VOLTAGE
CCT
CONTROL
OPTIONS
WP=Wall Pack
FC=Full Cutoff
40=40W 60=60W 90=90W
HU=100-277V
57=5700K
00=non-dimming
00=Default
Product Specifications CONSTRUCTION & MATERIALS Type
WPFC40 WPFC60 362*293*230 mm 465*350*232 mm Dimension (14.25*11.54*9.06") (18.31*13.78*9.13") Housing Die-cast aluminum Lens Type Glass
WPFC90 WP0040 465*350*232 mm 363*230*195 mm (18.31*13.78*9.13") (14.29*9.06*7.68")
WP0060 465*230*244 mm (18.31*9.06*9.61")
WP0090 465*230*244 mm (18.31*9.06*9.61")
ENVIRONMENTAL SYSTEM Work Environment Operating Temperature
Indoor and outdoor use -20℃~60℃(-4~140℉)
OPTICAL SYSTEM Type Luminous Flux Luminous Efficacy Color Temperature CRI Lumen maintenance at 6000h
WPFC40/WP0040 4000 lm Typ. 100 lm/W 5700 K 85 99%
WPFC60/WP0060 6000 lm
WPFC90/WP0090 8500 lm
WPFC40/WP0040 100~277VAC/0.31A 0W 40W <15% >0.9
WPFC60/WP0060 100~277VAC/0.48A 0W 60W <20%
WPFC90/WP0090 100~277VAC, 0.75A 0W 90W <20%
ELECTRICAL SYSTEM Type Input Voltage Off State Power Power Consumption THD Power Factor REGULATORY & VOLUNTARY
QUALIFICATIONS
ETL & cETL Listed (ETL No.: 4003329) DLC, LM79 CE, RoHS
www.atgelectronics.com
Toll free: 877-461-5333
E-mail: sales@atgelectronics.com
eLucent™ WP Series LED Wall Pack
SIDE
BOTTOM
BACK
TOP
Project
Type
Catalog #
EconoPak
DESCRIPTION EconoPak is a multi-purpose LED luminaire designed for indoor and outdoor area lighting applications. Delivering maximum lumens for 142,000 hours* while using only 30 Watts of power, its compact design with enclosed power supply make it ideal for such applications as flood lighting, sign lighting, landscape and general area lighting. The EconoPak can be mounted to a wall, ceiling or conduit, making it one of the most versatile LED luminaires in the market.
Wall Mount Luminaire
FEATURES l
l l l
Powered by a constant current power supply to achieve maximum efficiency (see separate data sheet) IP65 ingress protection Designed to meet Class 2 safety requirements 5-year warranty
CERTIFICATION l l
UL Listed USA+Canada File # E352127 LM-79 Test Report ENERGY DATA Input Voltage (V AC)
120 - 277
System Level Power (W)
30
Delivered Lumens (Lm)
2500
System Efficacy (Lm/W)
82
Correlated Color Temp (K)
5000
Minimum CRI
70
LED L70 Lifetime (Hrs)*
142,000
Operating Temp (ºC)
-20 to 40
† US LED product ‘Lifetimes’ refer only to the LED light engine, not the power source, and are based on the Illuminating Engineering Society’s TM21 methodology based on 25°C/77°F ambient temperature. The lifetimes are solely meant to be a guide for expected LED degradation and not a warranty or predictive of their actual life, which can be affected by ambient temperatures and other factors.
SPECIFICATIONS Dimensions (in)
7.75 x 6.625 x 4.25
Units/carton
1
Net weight
5.4 lbs
Environmental Rating
Wet
ORDERING INFORMATION Example: TL-WMB301-01-BZ
TL
WMB301
01
Series TL
Color WMB301
01
BZ
Bronze
WH White
Specifications and dimensions subject to change without notice.
|
DATASHEET 04.23.2014
|
|
|
|
Project
Type
Catalog #
DESCRIPTION The Canopy Star canopy LED luminaire from US LED is a perfect solution for parking structures, shopping area walkways, petrol stations and exterior canopies. The Canopy Star LED canopy is surface mounted for easy adaptation with a typical mounting height of 10 to 25 feet. Designed to illuminate area features with sharp, accurate color to increase security and visibility, the Canopy Star is cost effective to install and will replace conventional fluorescent, HPS and metal halide lighting. Specifications and dimensions subject to change without notice
FEATURES l l l l l l
Remarkable light output using only 94 Watts Class 2 compliant design (low voltage, limited power) L70 lifetime of 173,000 hours* Luminaire is IP66 compliant Protective coating added to resist corrosion 5-year warranty
CERTIFICATION l l l
UL 1598 certified by Intertek (ETL 4006735) DesignLights Consortium qualified LM-79 available
ENERGY DATA Input Voltage (VAC) System Level Power (W) Delivered Lumens (Lm) System Efficacy (Lm/W) Color Temperature (K) Color Rendering Index L70 Calculated Life (Hrs)* L85 Calculated Life (Hrs)* Operating Temp (ºC)
FIXTURE ORDERING INFORMATION Example: CNP1-50
CNP1
50
Series
Color Temp (K)
CNP1
120 - 277
347-480
94
102
9300
9300
99
91
5000
5000
80 min
80 min
173,000
173,000
79,000
79,000
-40 to 50
-40 to 50
* US LED product ‘Lifetimes’ refer only to the LED light engine, not the power source, and are based on the Illuminating Engineering Society’s TM21 methodology based on 25°C/77°F ambient temperature. The lifetimes are solely meant to be a guide for expected LED degradation and not a warranty or predictive of their actual life, which can be affected by ambient temperatures and other factors.
SPECIFICATIONS Dimensions (in)
18.62 x 18.62 x 2.75 1
Units/carton
50 5000K
Net weight Environmental Rating
9 lbs Wet
POWER SUPPLY INFORMATION Example: PUC-UNV1-3570
Series
Type
Drive Current
PUC
UNV1- (120-277 VAC)
3570
**PUC
UNV2 - (347/480 VAC)
3570
** High voltage fixture not DesignLights Consortium qualified
US LED product ‘Lifetimes’ refer only to the LED light engine, not the power source, and are based on the Illuminating Engineering Society’s TM21 methodology based on 25°C/77°F ambient temperature. The lifetimes are meant to be a guide for expected LED degradation and not a warranty or predictive of their actual life, which can be affected by ambient temperatures and other factors.
Project
Type
Catalog #
DESCRIPTION The Canopy Star canopy LED luminaire from US LED is a perfect solution for parking structures, shopping area walkways, petrol stations and exterior canopies. The Canopy Star LED canopy is surface mounted for easy adaptation with a typical mounting height of 20 to 30 feet. Designed to illuminate area features with sharp, accurate color to increase security and visibility, the Canopy Star is cost effective to install and will replace conventional fluorescent, HPS and metal halide lighting.
Canopy LED Luminaire Ultra Flux
FEATURES
192 W / 18,000 Lumens
Remarkable light output using only 192 Watts Class 2 compliant design (low voltage, limited power) L85 lifetime of >200,000 hours* Luminaire is IP66 compliant Protective coating added to resist corrosion 5-year warranty
l l l l l l
CERTIFICATION l l l
UL 1598 certified by Intertek (ETL 4006735) DesignLights Consortium qualified (**Low voltage) LM-79 available ENERGY DATA Input Voltage (VAC) System Level Power (W) Delivered Lumens (Lm) System Efficacy (Lm/W) Color Temperature (K) Color Rendering Index L85 Calculated Life (Hrs)* Operating Temp (ºC)
FIXTURE ORDERING INFORMATION Example: CNP2-50
CNP2
50
Series
Color Temp (K)
CNP2
120 - 277
347-480
192
210
18,000
18,000
94
86
5000
5000
70 min
70 min
> 200,000
> 200,000
-40 to 45
-40 to 45
* US LED product ‘Lifetimes’ refer only to the LED light engine, not the power source, and are based on the Illuminating Engineering Society’s TM21 methodology based on 25°C/77°F ambient temperature. The lifetimes are solely meant to be a guide for expected LED degradation and not a warranty or predictive of their actual life, which can be affected by ambient temperatures and other factors.
SPECIFICATIONS Dimensions (in)
18.62 x 18.62 x 2.75
Units/carton
50 5000K
Net weight Environmental Rating
1 9 lbs Wet
POWER SUPPLY INFORMATION Example: PUC-UNV1-7140
Series
Type
Drive Current
PUC
UNV1- (120-277 VAC)
7140
**PUC
UNV2 - (347/480 VAC)
7140
** High voltage fixture not DesignLights Consortium qualified
US LED product ‘Lifetimes’ refer only to the LED light engine, not the power source, and are based on the Illuminating Engineering Society’s TM21 methodology based on 25°C/77°F ambient temperature. The lifetimes are meant to be a guide for expected LED degradation and not a warranty or predictive of their actual life, which can be affected by ambient temperatures and other factors. Specifications and dimensions subject to change without notice
DATASHEET 05.06.2014
iBrightâ&#x201E;˘ 16W DLC IPS T8 LED Tube
Ordering Information Typical Order Example: T8ID12HU40F000 SERIES
GENERATION
SIZE
VOLTAGE
T8=T8 Tube
ID=DLC IPS
12=1.2m/4ft HU=100-277VAC
CCT 40=4000K 50=5000K
Lens Type F= Frosted Lens C= Clear Lens
Product Specifications CONSTRUCTION & MATERIALS Dimension Housing Finish Color Lens Type
4ft/1.2m Extrusion Aluminum and PC diffuser Silver Clear/Frosted
www.atgelectronics.com Toll free: 877-461-5333 E-mail: sales@atgelectronics.com
OPTIONS 000=Default
ENVIRONMENTAL SYSTEM Work Environment Operating Temperature
Indoor use (applicable for dry environments) -20~60℃ (-4~140℉)
OPTICAL SYSTEM Luminous Flux Luminous Efficacy Color Temperature CRI Lumen maintenance at 6000h
1600 lm 100 lm/W 4000K & 5000K 80 98.11%
ELECTRICAL SYSTEM Input Voltage/Current Off State Power Power Consumption Power Factor THD
100~277VAC 0W 16W >0.92 <20%
REGULATORY & VOLUNTARY QUALIFICATIONS Design Lights Consortium ETL/cETL CE, RoHS
www.atgelectronics.com Toll free: 877-461-5333 E-mail: sales@atgelectronics.com
iBrightâ&#x201E;˘ 23W DLC IPS T8 LED Tube
Ordering Information Typical Order Example: T8ID12HU40F023 SERIES
GENERATION
SIZE
VOLTAGE
T8=T8 Tube
ID=DLC IPS
12=1.2m/4ft HU=100-277VAC
CCT 40=4000K 50=5000K
Lens Type F= Frosted Lens C= Clear Lens
Product Specifications CONSTRUCTION & MATERIALS Dimension Housing Finish Color Lens Type
4ft/1.2m Extrusion Aluminum and PC diffuser Silver Clear/Frosted
www.atgelectronics.com Toll free: 877-461-5333 E-mail: sales@atgelectronics.com
OPTIONS 023=23W
ENVIRONMENTAL SYSTEM Work Environment Operating Temperature
Indoor use (applicable for dry environments) -20~60℃ (-4~140℉)
OPTICAL SYSTEM Luminous Flux Luminous Efficacy Color Temperature CRI Lumen maintenance at 6000h
2300LM 100 lm/w 4000K & 5000K 80 98.11%
ELECTRICAL SYSTEM Input Voltage/Current Off State Power Power Consumption Power Factor THD
100~277VAC 0W 23W >0.92 <20%
REGULATORY & VOLUNTARY QUALIFICATIONS Design Lights Consortium ETL/cETL CE, RoHS
www.atgelectronics.com Toll free: 877-461-5333 E-mail: sales@atgelectronics.com
Project
Type
Catalog #
DESCRIPTION
QubeLot2
The QubeLot2 evenly illuminates walkways, streets and parking areas. The classic design of this luminaire seamlessly blends into all forms of architecture. Highly efficient and long-lasting, the QubeLot2 is an ideal replacement for HID. Exceptional high-brightness LEDs result in higher light levels and significant energy savings. High-efficiency 5200K LEDs mounted to a metal-core circuit board and aluminum heat sink, ensure optimal thermal management and long life (L85 124,000 hrs).
Parking Lot Luminaire 4-Qube
FEATURES AND SPECIFICATIONS l
Type 5 medium light distribution and Type 2 medium distribution pattern available
l
Comes fully equipped with power supply
l
Bi-level light option available for dimmed-down lower power operation
l
EPA rating of fixture is 0.7/sq ft and mount is 0.13/sq ft
l
5-year warranty
CERTIFICATION l
UL Listed USA and Canada File# E338791
l
DesignLights Consortium qualified
3-QUBE
4-QUBE
ENERGY DATA Input Voltage (V AC)
ENERGY DATA 120 - 480
System Level Power (W)
Input Voltage (V AC)
104
Delivered Lumens (Lm)
9300
System Efficacy (Lm/W)
136
Delivered Lumens (Lm)
89
Correlated Color Temp (K)
120 - 480
System Level Power (W)
12,300
System Efficacy (Lm/W)
5200K
90
Correlated Color Temp (K)
5200K
L70 Calculated Life (hrs)*
289,000
L70 Calculated Life (hrs)*
289,000
L85 Calculated Life (hrs)*
124,000
L85 Calculated Life (hrs)*
124,000
Minimum CRI
65
Operating Temperature (°C)
Minimum CRI
-40 to 45
65
Operating Temperature (°C)
-40 to 45
* US LED product ‘Lifetimes’ refer only to the LED light engine, not the power source, and are based on the Illuminating Engineering Society’s TM21 methodology based on 25°C/77°F ambient temperature. The lifetimes are solely meant to be a guide for expected LED degradation and not a warranty or predictive of their actual life, which can be affected by ambient temperatures and other factors.
* US LED product ‘Lifetimes’ refer only to the LED light engine, not the power source, and are based on the Illuminating Engineering Society’s TM21 methodology based on 25°C/77°F ambient temperature. The lifetimes are solely meant to be a guide for expected LED degradation and not a warranty or predictive of their actual life, which can be affected by ambient temperatures and other factors.
SPECIFICATIONS
SPECIFICATIONS
Dimensions (in)
25.2 x 12.7 x 3.3
Units/carton
Dimensions (in)
1
Net Weight
14.5 lbs
Environmental Rating
25.2 x 12.7 x 3.3
Units/carton
1
Net Weight
Wet
16 lbs
Environmental Rating
Wet
ORDERING INFORMATION Example: QL2-1-UNVL-4-5M-52-0
QL2
1
52
Series
Variant Input Voltage # of Qubes
Light Dist Pattern
Color Temp
Options
QL2
1
52
0 0-10V Dimming
UNVL 120-277
3
5M 5 Medium
UNVH* 277-480
4
2M* 2 Medium
5200K
1 Photocell Socket 2 **DynaDimmer 3 **Photocell Socket & DynaDimmer
* Not DesignLights Conortium qualified ** Note: Options 2 and 3 not available with UNVH Input Voltage
Specifications and dimensions subject to change without notice.
Horizontal mounting only
DATASHEET 05.06.2014
Project
Type
Catalog #
DESCRIPTION
Dorado
The Dorado 6-Qube is an LED luminaire designed to be mounted vertically or horizontally in outdoor applications. High-performance LEDs provide light where you need it, at a fraction of the operating cost of HID technologies. With a lifetime of more than 200,000 hours*, the Dorado is the ideal replacement for 1000W metal halide fixtures. Slip-fitter, Pole Mount or Trunnion Mount options are available for easy and fast installation.
6-Qube Area Light Fixture
FEATURES l
Slip-fitter, Pole Mount and Trunnion Mount options available
l
Three light distribution patterns: Type 5M, Type 3M, and 120° angle
l
5-year warranty
CERTIFICATION l
UL approved (#E338791)
l
LM-80 pending
ENERGY DATA
l
LM-79 pending
Input Voltage (VAC) System Level Power (W)** Delivered Lumens (Lm)
120-277/347-480 288 30,800
System Efficacy (Lm/W)**
107
Correlated Color Temp (K)
5000K
L70 Calculated Life (hrs)*
>200,000
L85 Calculated Life (hrs)*
182,000
Minimum CRI Operating Temperature (°C)
70 -40 to 40
* US LED product ‘Lifetimes’ refer only to the LED light engine, not the power source, and are based on the Illuminating Engineering Society’s TM21 methodology based on 25°C/77°F ambient temperature. The lifetimes are solely meant to be a guide for expected LED degradation and not a warranty or predictive of their actual life, which can be affected by ambient temperatures and other factors. ** Measured at 277 VAC
SPECIFICATIONS Dimensions Units/carton Net Weight Environmental Rating
23.3” x 21.0” x 7.1” 1 26 lbs Wet
ORDERING INFORMATION Example: QD1-1-UNVL-5M-50-6-0
QD1
50
6
Series
Color
Voltage
Light Dist Pattern
Color Temp
# of Qubes
Options
QD1
1 Bronze
UNVL 120-277
5M
50 5000K
6 6-Qubes
0 None
2 White †
UNVH 347-480
3M
3 Black †
12
1 Photocell Socket
† Special order, not stocked Specifications and dimensions subject to change without notice.
DATASHEET 04.04.2014
ILTCaseLight
CaseLight is DLC Listed!
LED Refrigerated Case Lighting System
Make Your Prepared Foods POP With CaseLight™ LED Modules! • Easily Replace Existing Cooler/Freezer Display Case Fluorescent Lights • Easy Mounting Using TEK Screws or VHB Foam Tape When Space is Limited • No Need to Empty Shelves! • Lower Energy Bills and No Burned Out Bulbs! • Long Fixture Life - YEARS vs. Weeks/Months • Low Maintenance-5 Year Warranty on CaseLight Modules & Power Supplies • DLC Listed - Eligible for ALL Rebates • CaseLight Modules Made in the USA Improving on the success of ILT’s previous CaseLight modules for refrigerated/freezer display cases, ILT’s new, more efficient CaseLight module has even lower power consumption and higher overall optical performance for your reach-in coolers and freezers. For Retrofit or New cases, ILT CaseLight can be installed easily and cost-effectively. LED-based CaseLight modules provide all of the advantages of LED-based lighting including much longer life (greater than 50,000 hours), much lower energy consumption and much better lighting characteristics - brighter light focused on the merchandise. Plus all of ILT’s CaseLight modules are DLC listed qualifying for maximum utility rebates 45-Plus Years of ILT Lighting Experience Goes Into Every CaseLight
ILTINNOVATIONS
International Light Technologies, Peabody, MA (USA) • 45 Years of Lighting Experience – We Know Light!
Part Number
Description
Color Temp. (K)
Lumens
Energy (Watts) Life (Hours) CRI (Typical)
ILT48-BAO-W50CE
CaseLight, 48”, Brite Anodize, Center unit
5000
1200
15
50000
85
ILT48-BAO-W50LE
CaseLight, 48”, Brite Anodize, Left unit
5000
600
7.5
50000
85
ILT48-BAO-W50RE
CaseLight, 48”, Brite Anodize, Right unit
5000
600
7.5
50000
85
ILT48-BAO-W40CE
CaseLight, 48”, Brite Anodize, Center unit
4000
1160
15
50000
85
ILT48-BAO-W40LE
CaseLight, 48”, Brite Anodize, Left unit
4000
580
7.5
50000
85
ILT48-BAO-W40RE
CaseLight, 48”, Brite Anodize, Right unit
4000
580
7.5
50000
85
ILT48-BAO-W35CE
CaseLight, 48”, Brite Anodize, Center unit
3500
1160
15
50000
85
ILT48-BAO-W35LE
CaseLight, 48”, Brite Anodize, Left unit
3500
580
7.5
50000
85
ILT48-BAO-W35RE
CaseLight, 48”, Brite Anodize, Right unit
3500
580
7.5
50000
85
ILT60-BAO-W50CE
CaseLight, 60”, Brite Anodize, Center unit
5000
1600
20
50000
85
ILT60-BAO-W50LE
CaseLight, 60”, Brite Anodize, Left unit
5000
800
10
50000
85
ILT60-BAO-W50RE
CaseLight, 60”, Brite Anodize, Right unit
5000
800
10
50000
85
ILT60-BAO-W40CE
CaseLight, 60”, Brite Anodize, Center unit
4000
1547
20
50000
85
ILT60-BAO-W40LE
CaseLight, 60”, Brite Anodize, Left unit
4000
773
10
50000
85
ILT60-BAO-W40RE
CaseLight, 60”, Brite Anodize, Right unit
4000
773
10
50000
85
ILT60-BAO-W35CE
CaseLight, 60”, Brite Anodize, Center unit
3500
1547
20
50000
85
ILT60-BAO-W35LE
CaseLight, 60”, Brite Anodize, Left unit
3500
773
10
50000
85
ILT60-BAO-W35RE
CaseLight, 60”, Brite Anodize, Right unit
3500
773
10
50000
85
ILT70-BAO-W50CE
CaseLight, 70”, Brite Anodize, Center unit
5000
2000
25
50000
85
ILT70-BAO-W50LE
CaseLight, 70”, Brite Anodize, Left unit
5000
1000
12.5
50000
85
ILT70-BAO-W50RE
CaseLight, 70”, Brite Anodize, Right unit
5000
1000
12.5
50000
85
ILT70-BAO-W40CE
CaseLight, 70”, Brite Anodize, Center unit
4000
1940
25
50000
85
ILT70-BAO-W40LE
CaseLight, 70”, Brite Anodize, Left unit
4000
970
12.5
50000
85
ILT70-BAO-W40RE
CaseLight, 70”, Brite Anodize, Right unit
4000
970
12.5
50000
85
ILT70-BAO-W35CE
CaseLight, 70”, Brite Anodize, Center unit
3500
1940
25
50000
85
ILT70-BAO-W35LE
CaseLight, 70”, Brite Anodize, Left unit
3500
970
12.5
50000
85
ILT70-BAO-W35RE
CaseLight, 70”, Brite Anodize, Right unit
3500
970
12.5
50000
85
Power Supplies ILT-LPF-40-24 40 Watt, UL Class 2, 100-277VAC input, 24VDC output ILT-CEN-60-24 60 Watt, UL Class 2, 100-277VAC input, 24VDC output ILT-D24V100UNVA 100W, UL Class 2, 120-277VAC input, 24VDC output
10 Technology Drive, Peabody, MA 01960 978-818-6180 978-818-6181 fax www.intl-lighttech.com
International Light
Te c h n o l o gi e s
Installation Instructions Note – Wiring and mounting instructions are applicable for both center and end units Model Numbers – Example ILT60-BAO-W50CE ILTAABAOWBB CE (AA=Length-inches) (Brite Anodize (BB=color temp) (C=Configuration; E=External Power finish) Supply) ILT48 (48”)
“
35 (3500K)
CE (Center, External Power Supply)
ILT60 (60”)
“
40 (4000K)
LE (Left, External Power Supply)
ILT70 (70”)
“
50 (5000K)
RE (Right, External Power Supply)
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. B. Before installing, servicing or cleaning unit, switch power off at the service panel and follow appropriate lock out / tag out safety procedures. FOR YOUR SAFETY: Read and observe all CAUTIONS and WARNINGS shown throughout these instructions. While performing installations described, gloves, safety glasses or goggles should be worn. PREPARE ELECTRICAL WIRING: A. Electrical Requirements – This fixture must be powered by a Meanwell, 60W, 24VDC power supply, model CEN-60-24, ILT part number ILT-CEN-60-24, connected to a properly grounded branch circuit, protected by a circuit breaker. B. Grounding Instructions – This power supply must be connected to a grounded metal, permanent wiring system. C. Strain Relief Requirements – This fixture is equipped with a cord but no attachment plug. Therefore, the installer must include a strain relief sized properly for the cable and opening in the junction box it is attaching to. An example is the Heyco Products strain relief, part number 1150, or equivalent if routing wire into a junction box or through an access hole.
CI-101 Rev. A
Page 1
International Light Technolgies 978-818-6180 Brite Energy Solutions 308-367-4542
4/25/2012
TOOLS NEEDED: - Wire connectors - Wire cutters - Gloves - Tape measure - Wire stripper - Safety glasses - Center punch - Power drill - Screwdriver - #6 x 1 1/2” self-tapping screws
Prepare for Mounting Light Fixture to Mullion – using #6 x 1 1/2” self-tapping screws CAUTION – Turn off power to the mullion lighting system before removing any covers. - Measure the total length of the mullion to determine which model/length unit to install. Center the fixture vertically on the mullion. Mark the top and bottom of the fixture. - Measure the total width of the mullion and mark a vertical line, ½ the total width near the top, 6” from the top, 6” from the bottom. - Mark a horizontal line 6” down from the top of the fixture. Mark a horizontal line 6” from the bottom of the fixture. CAUTION – Prior to installing screws, make sure that there are no existing components inside the mullion in the areas to be drilled. Do not drill through “DO NOT DRILL” label. - Use power drill and screw bit and install 4, #6 x 1 1/2” self-tapping screws through the center indent of the fixture. Install 2-3 screws, one 6” from top, one 6” from bottom and one in the center if necessary. NOTE – Starting the screws into the fixture with the fixture outside the cooler may make it easier for installation. Screws can then be fully inserted into mullion while holding fixture in place.
Alternate Mounting Method High quality VHB-type foam tape may also be used to mount the fixtures. − Thoroughly clean the back of the fixture and the mullion surface. − Using 1/2”-3/4” wide VHB tape, apply tap to back surface of fixture to within 3” of top and bottom of fixture. CI-101 Rev. A
Page 2
10 Technology Dr., Peabody, MA 01960
4/25/2012 978-818-6180 978-818-6181 fax
− Dry fit fixture to mullion. Once fit is confirmed, peel release paper, align fixture and press against mullion for entire length of fixture.
Connect Wiring from Fixture CAUTION – Ensure that all connection points are sealed for damp location using the appropriate method per the NEC or local electrical code. -
Cut the fixture cable to the appropriate length to terminate to DC power at the Power Supply. Where necessary, insert the proper strain relief on the cable and secure to hole in mullion or junction box. Strip the cable jacket and then strip the individual two wires. Attach the Black wire to the Black wire of the power supply using twist-on wire connector. Attach the Red wire to the Red wire of the power supply using twist-on wire connector.
Connect Wiring to Power Supply CAUTION – Wiring to high voltage side of power supply to be accomplished by certified electrician in accordance with NEC or local electrical code.
Trouble-shooting and Maintenance Instructions CAUTION – Turn off power to the mullion lighting system before removing any covers. The following items can be replaced in the field: - 60W Power Supplies - LED flex strips (access to end of unit required)
TROUBLE-SHOOTING -
If an entire strip of LEDs are not lighted (one of the two strips for a center unit or the one strip of an end unit), either there is a wiring problem to that strip or the LED driver is defective. Check wiring connections to the unit at the driver. If the connections look OK, proceed to “Replacement of LED Driver”. If both LED strips are not lighted on a center unit or the single strip isn’t lighted on an end-unit, it is possible that power to the unit has been interrupted. Confirm that the cable to the unit is wired properly and securely to the DC power source.
Replacement of LED Flex Strip - Remove the 2, #4 screws securing the end-cap where the cable exits the unit. - Slide out the lens on the side of the defective LED flex strip. - Cut the two wires from the defective LED flex strip about 6” from the end of the strip. CI-101 Rev. A
Page 3
10 Technology Dr., Peabody, MA 01960
4/25/2012 978-818-6180 978-818-6181 fax
-
Remove the defective LED flex strip by peeling away from the housing. Install the new LED flex strip by peeling the release tape and sticking to the housing. Start at wired end positioning start of strip about 1â&#x20AC;? from end of housing. Continue down the full strip, pressing in between components to insure a good bond. Connect Red and Black wires to the wires previously cut. Attach using twist on wire nuts. Push the wire nuts inside extrusion. Slide in lens which was previously removed. Re-attach end-caps with 2 #4-40 screws previously removed.
-
Fixture Cleaning Instructions -
The lens and aluminum housing should be cleaned periodically with a mild liquid dish detergent. Do not use chemical cleaners on the lens. Keep the outside clean. Wipe with a clean cloth lightly dampened with mild liquid dish detergent. Dry with a clean, soft cloth. Do not use scouring pads, powdered cleaners, bleach or cleaners containing bleach because these products can scratch and damage the finish.
-
Door Configurations The ILT-CEN-60-24, 60W, 24VDC power supply can power up to 3 Center units. Here are three typical door configurations and the number of power supplies required for each. # of Doors # of Center # of End Units Units
# of Power Supplies
Notes
3
2
2
1
4
3
2
2
2 Centers-1 End; 1 Center-1 End
5
4
2
2
2 Centers-1 End per P.S.
3
2 Centers-1 End per P.S. It is possible to wire 2 Centers and 2 Ends on 1 P.S.
6
5
CI-101 Rev. A
2
Page 4
10 Technology Dr., Peabody, MA 01960
4/25/2012 978-818-6180 978-818-6181 fax
Page 1 of 4
ATG Electronics® T8 LED Tube(IPS) USER GUIDE
NOTE: Please read this entire manual to fully understand and safely use this product. Specifications are subject to change without notice. Please visit www.atgelectronics.com for the most recent user guide versions. Included in this Box ATG Electronics® iBright™ T8 LED Tube (IPS), 1 PCs Wire Nuts, 3 PCs User Guide, 1 Set
Important Instructions 1."NOT FOR USE IN TOTALLY ENCLOSED LUMINAIRES", "NE CONVIENT PAS À DES LUMINAIRES TOTALEMENT FERMÉS", "DO NOT USE WITH DIMMERS", "NE PAS UTILISER AVEC DES GRADATEURS","THIS DEVICE IS NOT INTENDED FOR USE WITH EMERGENCY EXITS", "NE CONVIENT PAS AUX SORTIES DE SECOURS". 2. The LED tube works directly at 100~277VAC. The installer must determine whether they have 100~277VAC at the luminaire before installation. 3. WARNING – Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. 4. WARNING – Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings. 5. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. 6. WARNING – To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. 7. WARNING: To avoid potential fire or shock hazard, do not use this retrofit kit in luminaires employing shunted bi-pin lampholders. Note: Shunted lamp holders are found only in fluorescent luminaires with Instant-Start ballasts. Instant-start ballasts can be identified by the words “Instant Start” or “I.S.” marked on the ballast. This designation may be in the form of a statement pertaining to the ballast itself, or may be combined with the marking for the lamps with which the ballast is intended to be used, for example F40T12/IS. For more information, contact the LED luminaire retrofit kit manufacturer. 8. Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder terminals. Instead installers should cut existing lampholder leads away from the lampholder and make new electrical connections to lampholder lead wires by employing applicable connectors. 9. Other warnings will not to lead to misuse.
www.atgelectronics.com
Toll free: 877-461-5333
E-mail: sales@atgelectronics.com REV1.1
Page 2 of 4
PLANNING THE INSTALLATION Before retrofitting fluorescent luminaires, please make sure the dimensions of existing luminaires are larger than the dimension noted below. T8 Luminaire Dimensions: (Unit: mm)
Note: 1. “W” represents the Width of luminaire(s), “L” represents the Length of luminaire(s). 2. If working with one-lamp luminaires, W = min. 100 mm If two-lamp luminaires, W = min. 300 mm If three-lamp luminaires, W = min. 450 mm If four-lamp luminaires, W = min. 600 mm 3. For 0.6m LED Tubes, L= 620 mm For 1.2m LED Tubes, L=1240 mm For 1.5m LED Tubes, L=1530 mm 4. This LED tube can only be used in luminaires which contain a maximum of 4 lamps of 0.6 m long and 1.2m long LED tubes, and max. 2 lamps for 1.5m long LED tubes.
ATG Electronics® iBright™ T8 LED Tube (IPS) Specifications Model
Input Voltage
Max Wattage
Dimension
T8ID06HUZZABBB
100~277 VAC
12W
589mm
T8ID12HUZZABBB
100~277 VAC
23W
1199mm
T8ID15HUZZABBB
100~277 VAC
27W
1499mm
www.atgelectronics.com
Toll free: 877-461-5333
E-mail: sales@atgelectronics.com
Page 3 of 4
Retrofit Luminaires with Electronic Ballast Installation Steps Step 1: Turn off main power before installation. For safety, make sure main power source is switched off before attempting to install. Step 2: Take off existing fluorescent light and disconnect the ballast. Step 3: Cut four leads of G13 lamp holders. (For detailed placement of the cuts, note the X’s on the wiring diagram labeled “Before” shown below.) Step 4: Reconnect lamp holder leads L and N to the supply wires of branch circuit according to the wiring diagram below. Both G13 sockets of the fixture should be connected to the power source directly. Step 5: Install fixture as before. Step 6: Adhere a label to the luminaire to the effect of “This luminaire has been modified and can no longer operate fluorescent lamps.” on the retrofitted luminaire, where readily visible during relamping. Step 7: Install the LED tube into the fixture.
Wiring Diagram for Electronic Ballast
Before CUT
CUT
After
www.atgelectronics.com
Toll free: 877-461-5333
E-mail: sales@atgelectronics.com
Page 4 of 4
Retrofit Luminaires with Magnetic Ballast Installation Steps Step 1: Turn off main power before installation. For safety, make sure main power source is switched off before attempting to install. Step 2: Take off existing fluorescent light and disconnect the ballast. Step 3: Cut the ballast output lead and cut the wirings of the starter. Both the ballast and starter need to remain in place. (For detailed placement of the cuts, note the X’s on the wiring diagram labeled “Before” shown below.) Step 4: Reconnect lamp holder leads L and N to the supply wires of branch circuit according to the wiring diagram below. Both G13 sockets of the fixture should be connected to the power source directly. Step 5: Install fixture as before. Step 6: Adhere a label to the luminaire to the effect of “This luminaire has been modified and can no longer operate fluorescent lamps.” on the retrofitted luminaire, where readily visible during relamping. Step 7: Install the LED tube into the fixture.
Wiring Diagram for Magnetic Ballast
Before CUT
CUT
After
www.atgelectronics.com
Toll free: 877-461-5333
E-mail: sales@atgelectronics.com