THIRD ANGLE PROJECTION
For explanation of dimensions, notes, etc., see BS 8888.
11SL (6m) MP
IF IN DOUBT, ASK.
REMOVE ALL BURRS AND SHARP EDGES.
ALL MATERIALS AND FINISHES TO BE COMPLIANT WITH RoHS 2 DIRECTIVE 2011/65/EU
ALL DEVIATIONS FROM DRAWING TO BE REPORTED TO DEVELOPMENT.
THIRD ANGLE PROJECTION
For explanation of dimensions, notes, etc., see BS 8888.
plate offset 3mm from top
tapped above and below slot for fixing channel. Use clearance holes in channel for drilling
holes tapped above both speaker covers. Use countersunk holes in speaker covers for drilling template.
tapped at top and bottom of flat section. Use countersunk holes in flat section for drilling
IF IN DOUBT, ASK.
REMOVE ALL BURRS AND SHARP EDGES.
ALL MATERIALS AND FINISHES TO BE COMPLIANT WITH RoHS 2 DIRECTIVE 2011/65/EU
6m Root Mounted Stepped Tubular Column c/w Vertical Channels, Mounting For LEDs & Speakers and Perch 1:40
ALL DEVIATIONS FROM DRAWING TO BE REPORTED TO DEVELOPMENT.
THIRD ANGLE PROJECTION
For explanation of dimensions, notes, etc., see BS 8888.
* Refers To The Indicative Heights Shown In 'HEIGHTS VIEW'
Orientations Measured Clockwise From Door Orientation (Door Is At 0° / Datum)
e.g. 4m@252° = Positioned In '4m Channels' Region of HEIGHTS VIEW and Rotated/Oriented 252° Clockwise From Door Orientation/Datum (8th Channel in Circular Sequence)
BASE STRIP CODES:
BD = Below Door
BP = Below Perch
APBLS = Above Perch, Below Low Speaker
APBHS = Above Perch, Below High Speaker
ADBP = Above Door, Below Perch
ALS = Above Low Speaker
AHS = Above High Speaker
11SL (6m)
4 Base Strip T00 - Default 4 AP@0°; AP@36°; AP@180°; AP@216°
5 Base Strip U02 - Lower Speaker High 3 ALS@252°; ALS@288°; ALS@324°
6 Base Strip U03 - Higher Speaker Low 3 APBHS@72°; APBHS@108°; APBHS@144°
7 Base Strip U05 - Higher Speaker High 3 AHS@72°; AHS@108°; AHS@144°
8 Base Strip U00 - Lower Speaker Low 3 APBLS@252°; APBLS@288°; APBLS@324°
9 Base Strip V00 - Below Door Centre 1 BD@0°
10 Base Strip W00 - Above Door Centre 1 AD@0°
11 Base Strip X01 - Left of Door (Below) 1 BD@36°
12 Base Strip X00 - Left of Door 1 ADBP@36°
13 Base Strip Y01 - Right of Door (Below) 1 BD@324°
14 Base Strip Y00 - Right of Door 1 ADPB@324°
15 Channel Solid A01 - Default (Middle Channels) 8 4m@72°; 4m@108°; 4m@144°; 4m@252°; 5m@72°; 5m@108°; 5m@144°; 5m@252°
16 Channel Solid A02 - Default Top 6 6m@72°; 6m@108°; 6m@144°; 6m@180v; 6m@252°; 6m@288°
17 Channel Solid A00 - Default 5 3m@72°; 3m@108°; 3m@144°; 3m@216°; 3m@252°
18 Channel Solid B00 - LED Channel 6 4m@180°; 4m@288°; 4m@324°; 5m@0°; 5m@36°; 5m@216°
19 Channel Solid C01 - Default Below LED (MIddle) 3 4m@0°; 4m@36°; 4m@216°
20 Channel Solid C00 - Default (Below LED) 2 3m@180°; 3m@288°
21 Channel Solid D01 - Default Above LED (MIddle) 3 5m@180°; 5m@288°; 5m@324°
22 Channel Solid D02 - Default Top (Above LED) 1 6m@216°
23 Channel Solid E07 - C. Bump Door Lower 1 3m@0°
24 Channel Solid E12 - C. Bump Door Upper 1 3m@0°
25 Channel Solid F01 - L. Bump Door Left 1 3m@36°
26 Channel Solid G08 - RBDR (Below LED) 1 3m@324°
27 Channel Solid H02 - CDL (Above LED) (Top) 1 6m@0°
28 Channel Solid I04 - CDU Top 1 6m@0°
29 Channel Solid J03 - LD (Above LED) Top 1 6m@36°
IF IN DOUBT, ASK.
ALL MATERIALS AND FINISHES TO BE COMPLIANT WITH RoHS 2 DIRECTIVE 2011/65/EU REMOVE ALL BURRS AND SHARP EDGES.
6m Root Mounted Stepped Tubular Column c/w Vertical Channels, Mounting For LEDs & Speakers and Perch 1:30
ALL DEVIATIONS FROM DRAWING TO BE REPORTED TO DEVELOPMENT.
All Dimensions in Millimetres unless stated otherwise.
FULL FRAME (TOP VIEW):
10N°. Segments Welded In Circular Sequence
Datum / Door Orientation / 1st Segement Of Frame
WITH MOUNTING RING WELDED (SEE SHEET 3)
M4 holes drilled and tapped using countersunk holes in the 2 shroud halves for drilling template. (3N° holes per leg, unless at 0° or 180° from door aperture, in which case 2 sets of 3N° holes required).
Ø24 HOLE IN FRONT SEGMENT ONLY (SEGMENT 1 OF 10)
Datum / Door Orientation / 1st Segement Of Frame
Dished Rim Welded To Frame - See Sheet 3 For Detail
2N°. D&T M4 Holes (Continued From LED Mounting Ring Into Underside of RHS Frame)
'Seat A' Column Configuration
Where multiple views are shown 3rd Angle Projection is assumed.
Datum / Door Orientation / 1st Segement Of Frame
3 Planks Per 36° Segment Fixed To Frame With Screws - Left/Right Plank (x2) and Centre Plank (x1)See Sheet 5 For Detail
Required Between Shroud (1 Half Shown) and Dished Rim
1 Holes For LED Mounting/ Cable Routing Added; Plank Depth Reduced 21/01/2022
3mm Thk. Ring For Mounting Flexible LED (Welded To Bottom of RHS) - See Sheet 4 For Isolated View
Fully Weld Side and Bottom Edges of RHS To Column; Weld Top Edge But Grind Flush To Allow Column Strips (Flat Section) To Sit Flush Against Perch
www.fabrikat.co.uk
Drg No. 46323-1
See Sheet 2 For Shroud Detail (Bolted To Frame)
Datum / Door Orientation / 1st Segement Of Frame
TOP VIEW (THIS FACE WELDED TO RHS FRAME)
NOTE - CHECK RING CAN FIT INSIDE DISHED RIM PRIOR TO DRILLING 1109 1008
TOP VIEW (THIS FACE WELDED TO RHS FRAME)
21° 21° 21° 21° 21° 21° 21° 21° 21° 21° 26°
/ Door Orientation / 1st Segement Of Frame 21°
1089.5 PCD
and Tap 2N°. M4 Holes (Continue Into RHS 21°
DETAIL 21°
Drill and Tap 15N°. M3 Holes (Excluding Datum) on Ø1089.5 PCD
1N°. Ø17 Hole (Aligned With Larger Hole in RHS) 21°
All Dimensions in
Where multiple views are shown 3rd Angle Projection is assumed.
Ø17 HOLE = 1 M3 D&T HOLE = 19 M4 D&T HOLE = 2 Revisions Rev. Description Date - See Sheet 1 -
TOTAL:
2022 © Copyright Notes Customer: Contract: LED Mounting Ring Ref. TS Drawn By: MP Chk'd: Ring For Mounting Flexible LED Strip Title Sheet 4 of 5 Scale:1:12 Fax. 01623 442233 Tel: 01623 442200 Hamilton Road, Sutton in Ashfield, Nottinghamshire NG17 5LN 21/01/2022 Date: Drg No.
Column
LED Slot Aperture
2N°. M5 Nuts To Secure Studding To Angle Brackets
2N°. 40 x 20mm Channels With Jog To Accomodate 50mm Overlap of LED Channel
40 x 20mm Channel For LED With Central Fin
1m Ilum Mark 2 LED
DETAIL A SCALE 1 : 3
2N°. Angle Brackets
Nottingham Limited, Hamilton Road, Sutton in Ashfield Notts. NG17 5LN
www.fabrikat.co.uk technical@fabrikat.co.uk
Notes
Tel.01623 442200
Fax.01623 442233
All dimensions in millimetres unless stated otherwise.
When Multiple views are shown 3rd Angle Projection is assumed.
Revisions
Rev. Description Date
Studding Welded to (LED-Securing) Channel and Fastened To Angle Bracket With Nut
2021 © Copyright
Title
LED Channel Assembly Detail
Drg No.
Scale:1:10
Sheet 1 of 2 46190-0
Drawn By: Chk'd:
Ref.
TS
Assembly Detail
Contract:
Customer:
Nottingham Limited, Hamilton Road, Sutton in Ashfield Notts. NG17 5LN
Revisions
Title
2021 © Copyright
Channels Below LED (Recurring Feature)
Drg No.
46289-0
Scale:1:1 Sheet 4 of 15
Fax.01623 442233
Tel.01623 442200 www.fabrikat.co.uk technical@fabrikat.co.uk
Notes
All dimensions in millimetres unless stated otherwise.
When Multiple views are shown 3rd Angle Projection is assumed.
Drawn By: Chk'd:
TS MP
Ref.
Below LED (Recurring Feature)
Contract:
Customer:
Date: 08/12/2021
See Sheet 4 For Upper Jogged Section To Suit LED Channel
See Sheet 6 For Lower Jogged Section To Suit LED Channel
(5mm Radius Edges)