Product Guide The complete guide to Carestream Dental products
November 2013
Why have we created this product guide? This brochure aims to help you choose the right products from Carestream Dental for your practice. With this in mind, we have summarised the most important advantages and selling points of our digital radiography and imaging systems.
For further information please contact your local authorised dealer:
Register your product online and get an additional year of warranty! http://register.carestreamdental.com/eamer Visit our website: www.carestreamdental.com E-mail: europedental@carestream.com 22
CS 1500
Caries screening intraoral camera
CS 1200 / 1500 / 1600
CS 1200
The ideal conversation starter!
Intraoral cameras
Superior image quality at an affordable price.
CS 1600
X-ray units
CS 2100 / CS 2200
...optimised for digital!
Digital intraoral radiography
The RVG Sensor at 30 years: From Invention to Innovation. ...the best sensor! ...the best sensor Wireless!
CS 7600
NEW
Ideal for everyday use Panoramic and cephalometric system
CS 8000C
The 3-in-1 solution: panoramic, cephalometric and 3D
CS 8100
CS 9000 Family
LOGICON Caries Detector Software
Communicator Patient Software
...one software for all products!
Carestream Dental Imaging Software
The ultimate all-in-one solution
CS 7400 / CS 7600
CS 7400
CS 8000C / CS 8100 CS 9000 / CS 9300
Smart imaging plate system
CDIS/LOGICON/ COMMUNICATOR
Intraoral and panoramic digital solution
Computed radiography
RVG 6500
Digital extraoral radiography
RVG 6100
Software
RVG 5100
RVG 5100 / 6100 / 6500
CS 2200
CS 2100
CS 9300 Family
3
Intraoral imaging
CS 1200
Intraoral Camera Superior image quality at an affordable price
Features and benefits ●● ●● ●●
●● ●● ●●
High image resolution (1024 x 768) Enhanced patient communication Easy to share - Supporting both PC and analog display, the camera’s direct connections ensure fast and easy sharing between operatories Lightweight and compact, the CS 1200 fits easily in hands of all sizes and minimizes operator fatigue The rounded head and tapered shape of the camera ensure patient comfort 6-LED illumination system that automatically adjusts to ensure perfectly lit images in any lighting condition
Product
Cat. No.
CS 1200 Wired USB
6559991
Intraoral Cameras 3-year Care-Protect
5307368
Technical specifications Sensor
Micron 1/2.5 CMOS
Video resolution Image resolution Focus range Angle of view Field of view Focus Light source Video output Connection
640 (H) x 480 (V) 1024 (H) x 768 (V) 3 mm – 25 mm 90° 80° Fixed Focus 6 White LED array TV-NTSC, TV-PAL, S-Video USB 2.0
Recommended PC requirements s. page 31
4
CS 1200 / 1500 / 1600
Intraoral imaging
CS 1500
Intraoral Camera The ideal communication tool for any dental practitioner. Elegantly styled and easy to use, Carestream Dental’s first wireless intraoral camera delivers stunning images with the convenience and freedom of Wi-Fi connectivity. Features and benefits ●● ●● ●● ●● ●● ●● ●●
Best-in class image quality and resolution Patented true autofocus technology With built-in Wi-Fi support, the camera provides total freedom of movement White LED exposure ensures uniform and bright illumination Intraoral and extraoral imaging Compatible with computer and video screens Available as wired and wireless configuration
Product
Cat. No.
CS 1500 Wireless
6559801
CS 1500 Wired USB
6559819
Intraoral Cameras 3-year Care-Protect
5307368
Technical specifications Sensor
Micron 1/2.5 CMOS
Video resolution
640 (H) x 480 (V)
Image resolution Focus range Angle of view Field of view Focus Light source Video output Connection
1024 (H) x 768 (V) 1 mm to infinity 90° 80° Autofocus 8 White LED array TV-NTSC, TV-PAL, VGA, S-Video USB 2.0
Recommended PC requirements s. page 31
5
Intraoral imaging
CS 1600
Intraoral Camera With the CS 1600, practitioners can easily identify then communicate potential inicipient caries and treatment options during exams, resulting in improved treatment acceptance and enhanced patient health. Automatic generation and display of results simplify the examination process and help the dentist communicate the various stages of possible infection to patients in a way they can really understand. Easy-to-use imaging software allows practitioners to capture, store and retain patient images. Features and benefits ●● ●● ●● ●● ●● ●●
●●
Assists with early suspicious caries identification Best-in class image quality and superior ease of use Unique liquid lens technology that focuses like the human eye for effortless image capture Dual capture buttons allow for easy operation for both upper and lower arches High tech lighting system with three layer illumination, 6 Blue LEDs, 12 White LEDs (6 polarized and 6 non-polarized) Enhanced white light images: the CS 1600 provides enhanced white light images for the clearest view of tooth surfaces The practitioner can capture areas of interest on still images for further analysis of the suspected caries by using the exclusive FIRE (Fluorescence Imaging with Reflectance Enhancement) technology Product
Cat. No.
CS 1600 Wired USB
6559389
Intraoral Cameras 3-year Care-Protect
5307368
Technical specifications Sensor Video resolution Image resolution Focus range Angle of view Field of view Focus Light source Video output Connection
Micron 1/2.5 CMOS 640 (H) x 480 (V) 1024 (H) x 768 (V) 1 mm - infinity 90° 80° Autofocus 3 layer illumination, 6 blue LEDs, 12 White LEDs array None USB 2.0
Recommended PC requirements s. page 31
6
CS 1200 / 1500 / 1600
Intraoral radiography
CS 2100
Intraoral X-Ray System
CS 2100 / CS 2200
Obtain sharp, high contrast images quickly and easily with this affordable high-frequency generator - ideal for your basic intraoral needs. Features and benefits ●● ●● ●● ●● ●●
High-frequency DC technology at the price of a conventional generator Sharp and high-contrast images for easy diagnosis Easy-to-use and fast-setting generator thanks to its improved timer design Dose display after each exposure Ideal for digital sensors or analog films
Product
Cat. No.
CS 2100 with short arm (170 cm)
5153671
CS 2100 with standard arm (188 cm)
5153663
CS 2100 with long arm (205 cm)
5153655
CS 2100 3-year Care-Protect
5306782
Technical specifications Power supply X-ray generator Tube voltage Tube current Focal spot Focal spot/skin distance
230 – 240 V Very high frequency – DC (300 kHz) 60 kV 7 mA 0.7 mm IEC 200 mm (8 in)
X-ray units are also available with 100-110-130 V
7
Intraoral radiography
CS 2200
Intraoral X-Ray System Ensure superior digital image quality in any environment with the CS 2200 system. Designed for safety and efficiency, the intuitive unit helps you make more accurate diagnoses. Features and benefits ●●
●● ●● ●●
●● ●● ●●
●● ●●
Maximum image quality with minimum exposure for better patient treatment thanks to its pre-programmed control unit Compatible with TROPHY IRIX installed base Designed for safety and efficiency Total control on tube voltage (60 or 70 kV) for high contrasted or high latitude images depending on examination requirements Intuitive and easy-to-use thanks to its user’s interface including a dental arch timer Optimized for RVG sensors as well as for Kodak film High frequency for better patient safety - reduces the radiation dose up to 25% in comparison with a standard generator After each exposure, the dose level is displayed for simple dose monitoring Multiple configurations available, including ceiling mount and a new wall mounting option fully compatible with the Irix installed base Product
Complete unit with wall mount for replacing existing IRIX systems as well as a variety of other popular manufacturers’ systems. Existing holes can be used for wall mounting
Cat. No.
Irix Mount
Irix mount series CS 2200 for Irix replacement with short arm (170 cm)
5159652
CS 2200 for Irix replacement with standard arm (188 cm)
5159645
CS 2200 for Irix replacement with long arm (205 cm)
5159660
Technical specifications Power supply
Wall mount series
8
Wall Mount
CS 2200 with short arm (170 cm)
5153580
CS 2200 with standard arm (188 cm)
5153572
CS 2200 with long arm (205 cm)
5153564
CS 2200 3-year Care-Protect
5306782
X-ray generator Tube voltage Tube current Focal spot Focal spot/skin distance
230 – 240 V Very high frequency – DC (300 kHz) 60 kV, 70 kV 7 mA 0.7 mm IEC 200 mm (8 in)
X-ray units are also available with 100-110-130 V
Digital intraoral radiography
RVG 5100
Digital Radiography System Affordable high quality digital imaging solution for all applications.
●● ●● ●● ●● ●●
True resolution of 14 line pairs/mm - equivalent to or better than most of the other manufacturers’ sensors Second only to the RVG 6500 and RVG 6100 systems in image quality Cable positioned on the back of the sensor for precise and effortless positioning Rounded corners for increased patients’ comfort Easy handling and flexibility thanks to USB cable Excellent for use in multiple chair practices
Product
RVG 5100 / 6100 / 6500
●●
CS 2100 / CS 2200
Features and benefits
The RVG 5100 system comes with a RINN XCP-Ora kit.
Cat. No.
RVG 5100 size 1
5154802
RVG 5100 size 2
5154794
RVG Family 3-year Care-Protect
5307350
Technical specifications Sensor size 1
True image resolution Pixel size External dimensions Dimensions of active area Number of pixels Purpose Technology Connection
Sensor size 2
14 lp/mm 14 lp/mm 18.5 μm 18.5 μm 27.5 x 37.7 mm 32.2 x 44.1 mm 22 x 30 mm (660 mm2) 27 x 36 mm (972 mm2) 1.92 million 2.76 million All-purpose sensor Bitewing examinations CMOS sensor with optical fiber technology USB 2.0
Recommended PC requirements s. page 31 Logicon software s. page 29
9
Digital intraoral radiography
RVG 6100
Digital Radiography System Can be used for all dental x-ray procedures but is especially suited for endodontics where a high degree of image detail is required. Features and benefits ●● ●● ●● ●● ●● ●● ●●
The best sensor technology in the market for 30 years Highest measurable resolution (20 line pairs/mm) for quick and confident diagnoses The unrivalled detail reproduction you need for complex examinations Ergonomically designed for easy and accurate positioning Rounded corners for your patients’ ease Pediatric size 0 with up to 40% less radiation than larger sensors USB cable – easy handling and flexible - for use in multi chair practices
Product
Cat. No.
RVG 6100 size 1
5154828
RVG 6100 size 2
5154810
RVG 6100 size 0
5155114
RVG Family 3-year Care-Protect
5307350
The RVG 6100 system comes with various accessories, including a sample pack of disposable hygienic sheaths, positioners, and mounting holder.
Technical specifications Sensor size 0
True image resolution Pixel size External dimensions Dimensions of active area Number of pixels Purpose Technology Connection
15 lp/mm > 20 lp/mm 18.5 μm 18.5 μm 22.2 x 30.8 mm 27 x 36 mm 2 17 x 22 mm (374 mm ) 22 x 30 mm (660 mm2) 1.08 million 1.92 million Pediatric examinations All-purpose sensor CMOS sensor with optical fiber technology USB 2.0
Recommended PC requirements s. page 31 Logicon software s. page 29
10
Sensor size 1
Sensor size 2
> 20 lp/mm 18.5 μm 32.2 x 44.1 mm 27 x 36 mm (972 mm2) 2.76 million Bitewing examinations
Digital intraoral radiography
RVG 6500 System
As the first RVG sensor to offer Wi-Fi compatibility, the RVG 6500 system delivers the same exquisite image quality as our wired models. Features and benefits
●● ●● ●● ●● ●● ●● ●●
Superior image quality for enhanced diagnostic capability thanks to the highest true resolution in the industry (20 line pairs/mm) Improved positioning for less retakes and increased productivity in the practice Wi-Fi connectivity for faster and more secure image transfer Compatible with the iPad, iPod touch and iPhone for enhanced portability in and outside the practice Great patient comfort with sensor rounded corners Sensors available in three sizes Robust & reliable
Product
RVG 5100 / 6100 / 6500
●●
Cat. No.
RVG 6500 size 1
5159702
RVG 6500 size 2
5159710
RVG 6500 size 0
5159926
RVG Family 3-year Care-Protect
5307350
The RVG 6500 system comes with various accessories, including a sample pack of disposable hygienic sheaths, positioners, and mounting holder.
Technical specifications Sensor size 0
True image resolution Pixel size External dimensions Dimensions of active area Number of pixels Purpose Technology Wireless technology Lithium battery charge cycle Control box dimensions
Sensor size 1
Sensor size 2
15 lp/mm >20 lp/mm >20 lp/mm 18.5 μm 18.5 μm 18.5 μm 22.2 x 30.8 mm 27.5 x 37.7 mm 32.2 x 44.1 mm 17 x 22 mm (374 mm²) 22 x 30 mm (660 mm²) 27 x 36 mm (972 mm²) 1.08 million 1.92 million 2.76 million Pediatric examinations All-purpose sensor Bitewing examinations CMOS, scintillator, optical fiber with shock-resistant protective layer Wi-Fi 802.11 g Approx. 180 images 83 (H) x 47 (W) x 16 (D) mm
Recommended PC requirements s. page 31, Logicon software s. page 29
11
12 ü ü ü
iPad / iPhone / iPod touch review feature
Sensor waterproofness
Twain compatibility
lll Best
ll
l Good ll Better
lll
Pedodontics
lll
lll
Periodontics
lll
lll
lll
Implantology
lll
Caries detection
Endodontics
lll
General diagnostics
Systems
Applications RVG 6500 / 6100 Systems
ü
Special Size 0 kit
RVG 6500 / 6100 Systems
ü
Toothbrush type holders
Size 0
ü
RINN type baskets
*Size 0 resolution: 15 lp/mm
ü
RINN XCP-ORA kit
Positioning accessories delivered with the system:
ü
0-1-2
> 20 lp/mm
Wi-Fi
RVG 6500 System
iPad / iPhone / iPod touch acquisition feature
Sensor size
True resolution
Connectivity
Features
Comparative Matrix for RVG Range
Size 1
ll
l
ll
l
ll
ll
RVG 5100 System
ü
ü
ü
ü
ü
ü
RVG 6500 / 6100 Systems
Size 2
lll
lll
l
lll
lll
ll
ll
l
ll
ll
RVG 5100 System
N/A
×
×
ü
ü
ü
ü
×
× ü
1-2
14 lp/mm
USB2
RVG 5100 System
0-1-2
> 20 lp/mm*
USB2
RVG 6100 System
Computed radiography
CS 7400
Digital Radiography System The phosphor plate system for all formats intraoral, panoramic and cephalometric radiography. The easy way to convert your dental practice to digital. Features and benefits
●● ●● ●● ●●
Low-cost complete digital entry-level solution As easy as film with all the benefits of digital - similar workflow to film minimizes learning curve with easy to use product Compact digital radiography imaging solution (intraoral/extraoral) Very easy handling and excellent image quality One-step process for full mouth series of X-ray images Our thin and flexible durable plates reduce the need for replacement
Product CS 7400 system
RVG 5100 / 6100 / 6500
●●
CS 7400 / CS 7600
●●
Cat. No. 8470411
Technical specifications Imaging plate scanning resolution
Plate Sizes
System dimensions (without bracket) Weight approx.
Panoramic / Cephalometric High resolution High speed Intraoral High resolution High speed Panoramic – 15 x 30 cm Cephalometric – 18 x 24 cm Size 0 – 21 mm x 31 mm Size 1 – 24 mm x 40 mm Size 2 – 31 mm x 41 mm Size 3 – 27 mm x 54 mm Size 4 – 57 mm x 76 mm 24 (H), 48 (W), 38 (D) cm 16 kg
7 lp/mm 4,5 lp/mm 10 lp/mm 8 lp/mm
Recommended PC requirements s. page 31
13
Computed radiography
CS 7600
Intraoral Imaging Plate System The CS 7600 makes the move to digital imaging simple and affordable. The first imaging plate system to feature a fully automated and secure workflow designed to improve productivity and user experience by allowing multiple operators to use the system on multiple patients at the same time, with no waiting required and no risk of errors. Features and benefits ●● ●● ●● ●● ●●
●●
High image resolution (17 lp/mm) with a wide exposure range First image viewable in as few as 5 seconds. Full Mouth Series from 2-6 minutes* Can be used by multiple users at the same time Built-in memory eliminates the risk of lost images and allows users to scan plates during network failure Scan & Go technology - Fully secure and automated workflow, avoiding plate mix-up, confusion, and mistakes - Secured multi-patients and multi-users management at the same time - Bulk scanning reduces operating time Remote services help reduce downtime and optimize service cost Product
Cat. No.
CS 7600
1014307
CS 7600 Scan & Go device
1014315
CS 7600 3-year Care-Protect
5306659
Technical specifications Imaging plate scanning resolution
Plate Sizes
Power supply Display System dimensions (without bracket) Weight approx. Recommended PC requirements s. page 31
14
Super high resolution High resolution High speed Size 0 – 22 mm x 35 mm Size 1 – 24 mm x 40 mm Size 2 – 31 mm x 41 mm Size 3 – 27 mm x 54 mm Size 4 – 57 mm x 76 mm 100-240 V(ac), 50/60 Hz, 1,5 A 7,5 cm (3.5”) color LCD display 26,6 (H), 23,7 (W), 25,9 (D) cm 6 kg
17 lp/mm 14 lp/mm 8 lp/mm
Digital extraoral radiography
CS 8000C
Digital Panoramic and Cephalometric System An affordable system from the inventor of “one shot” technology for clear and perfectly exposed cephalometric images in seconds. Features and benefits
●● ●● ●● ●● ●● ●●
●●
Product
Cat. No.
CS 8000C system patient entry and ceph arm on the right
8479511
CS 8000C system patient entry and ceph arm on the left
1761089
CS 8000C 3-year Care-Protect
5307384
CS 7400 / CS 7600
●●
“One shot” technology captures the image in less than a second reducing exposure time and risk of blurred images No retakes and outstanding image sharpness thanks to the short exposure times for excellent diagnosis Unique image format 20 x 26 cm Two-sensor system for improved reliability - no handling from panoramic to ceph mode required Convenient patient positioning for better treatment 6 cephalometric programs to answer all the examination needs 3 automatic ortho enhancement filters revealing even more detail User-friendly, easy to learn computer-controlled user interface for fast program settings – almost no training needed Minimal space requirement (only 2.30 m width)
Technical specifications Cephalometric Modality Technology Sensor technology Gray scale Sensor matrix Magnification Exposure time Radiological exam options Cephalometric formats
One shot CCD 16384 - 14 bit 1360 x 1840 pixels 1.14 0.1 to 3.2 seconds Lateral, frontal AP / PA, oblique, submentovertex, Carpus 20 x 26 cm
CS 8000C / CS 8100 CS 9000 / CS 9300
●●
X-Ray Generator and other specifications Tube voltage 60 - 90 kV Tube current 2 - 15 mA Frequency 140 kHz Tube focal spot 0.5 mm (IEC 60336) Total filtration > 2.5 mm eq. Al Unit dimensions 2250 (L) x 1261 (D) x 2315 (H) mm Weight 145 kg Recommended PC requirements s. page 31
15
Digital extraoral radiography
N EW
CS 8100
Extraoral Imaging System The sleek and simple panoramic unit that’s ideal for everyday use. Blending advanced technologies in an ultra-compact design, the system provides everything you need to capture high-quality, crystal-clear images in seconds. Features and benefits ●● ●● ●● ●● ●● ●● ●● ●●
Compact, slim unit – ideal for tight spaces Versatile imaging programs cover all your daily panoramic needs Use artifact-free image filters to adjust contrast and sharpness with one click Acquire images in 10 seconds; then access them instantly Convenient and practical face-to-face patient positioning Wheelchair accessible Includes our user-friendly and powerful imaging software Exclusive 2D+ Technology: allows for buccal/lingual exploration and visualization of multiple slices for more details than ever Product
Cat. No.
CS 8100
5303045
CS 8100 3-year Care-Protect
5310321
Technical specifications Panoramic Modality Sensor technology Gray scale Sensor matrix Magnification Exposure time Exposure mode Radiological exam options Input voltage (AC)
CMOS 4096 - 12 bits 64 x 1312 pixels 1.2 (± 10%) 4 to 14 seconds 4 patient sizes (child, small, medium, large) Full panoramic, segmented panoramic, maxillary sinus, LA TMJ x 2, LA TMJ x 4, 2D+ 220 - 240 V - 50/60 Hz 100 - 130 V - 50/60 Hz
X-Ray Generator and other specifications Tube voltage 60 - 90 kV Tube current 2 - 15 mA Frequency 140 kHz Tube focal spot 0.5 mm (IEC 60336) Total filtration > 2.5 mm eq. Al Unit dimensions 330 (L) x 894 (D) x 1596 (H) mm Weight 72 kg Recommended PC requirements s. page 31
16
Digital extraoral radiography
CS 9000
Extraoral Imaging System High-end system for creating excellent digital panoramic images. Upgradable to 3D and/or Ceph. Features and benefits ●● ●●
●● ●● ●● ●●
Convenient and practical “face-to-face” positioning Excellent image quality thanks to focal trough adaptable to jaw morphology and improved sensor technology 5 panorama programs (see technical specifications) and 12 anatomical settings available User-friendly, computer-controlled user interface for fast program settings on the device and the software Compact design makes positioning easier than ever Upgradable to the CS 9000C system for ceph. For 3D, choose the CS 9000 3D system. For pan, ceph and 3D select the CS 9000C 3D system
Product
Cat. No.
CS 9000
5157433
Ceph upgrade
5211016
3D upgrade
5157516
CS 9000 3-year Care-Protect
5307376
CS 8000C / CS 8100 CS 9000 / CS 9300
Technical specifications s. page 21 Recommended PC requirements s. page 31
17
Digital extraoral radiography
CS 9000C
Panoramic and Cephalometric System 2-in-1 system with panoramic and cephalometric functionality. One shot cephalometric imaging for higher image quality. Upgradable to 3D. Features and benefits ●● ●● ●●
●● ●●
●●
●●
High-performance 2-in-1 radiography system (pan and ceph) The ideal choice for all of your orthodontic tracing needs Recognize landmark and anatomical structures and trace them automatically with our included Carestream dental imaging software Exclusive range of 5 image formats from 18x18 to 30x30 cm Highest quality cephalometric images within less than a second and with low radiation thanks to “one shot” technology 3 automatic ortho enhancement filters allows improving of image clarity and outlining soft tissue with just one click Upgrade to the 9000C 3D system with focused-field 3D imaging for even more diagnostic capabilities
Product CS 9000C
5159041
CS 9000C 3-year Care-Protect
5307384
Technical specifications s. page 21 Recommended PC requirements s. page 31
18
Cat. No.
Digital extraoral radiography
CS 9000 3D
Extraoral Imaging System The CS 9000 3D system‘s focusedfield of view is ideal for endodontics, implantology and dental surgery.
Features and benefits ●●
●●
●● ●●
●●
●●
Affordable two-in-one solution, combining real 3D technology and real panoramic technology in a single system The system delivers 3D exams with the highest resolution in the industry and high quality panoramic image Lowest dose 3D exams in the industry* covering a wide scope of clinical needs Combines the benefits of focused field 3D imaging (5 x 3,7 cm) with 3D stitching program (up to 8,5 x 6,6 x 3,7 cm) Easy to use and to integrate into the practice with our Carestream dental imaging software, intuitive 3D Module and without any sensor manipulation Face-to-face patient positioning reduces the risk of retakes
*According to study by ICRP: International Committee of Radio Protection
Cat. No.
CS 9000 3D
5157458
Ceph upgrade
5211016
CS 9000 3D 3-year Care-Protect
5307392
CS 8000C / CS 8100 CS 9000 / CS 9300
Product
Technical specifications s. page 21 Recommended PC requirements s. page 31
19
Digital extraoral radiography
CS 9000C 3D
Extraoral Imaging System The 3-in-1 solution for your imaging needs, the CS 9000C 3D system combines the power of focused-field 3D with cutting-edge panoramic and one-shot cephalometric imaging.
Features and benefits ●●
●● ●● ●●
●●
Same features as the CS 9000 3D system, plus cephalometric imaging, offering a range of new diagnostic possibilities 5 image formats in the range from full skull 30x30 cm to18x18 cm small field for lower dose exposures Automatic landmark recognition saves time and improves the workflow Delivers exceptional image quality thanks to exclusive and best in class „one shot“ technology 3 automatic ortho enhancement filters offers unprecedented detail and anatomical views
Product CS 9000C 3D
5159009
CS 9000C 3D 3-year Care-Protect
5307400
Technical specifications s. page 21 Recommended PC requirements s. page 31
20
Cat. No.
Digital extraoral radiography
CS 9000 / CS 9000C / CS 9000 3D Technical specifications 3D Modality Technology Sensor technology Gray scale Field of view (cm) Voxel size (Îźm) Reconstruction time
Digital Volumetric Tomography (DVT) CMOS 16384 - 14 bit Single volume: 5 x 3.7 cm (Diam x H) Stiched volumes: 9.3 x 7.4 x 3.7 cm 76.5 x 76.5 x 76.5 Îźm Less than 2 minutes
Cephalometric Modality Technology Sensor technology Gray scale Sensor matrix Magnification Exposure time Radiological exam options Cephalometric formats
One shot CCD 16384 - 14 bit 2100 x 2092 pixels 1.14 0.1 to 3.2 seconds Lateral, frontal AP / PA, oblique, submentovertex, Carpus 18 x 18 cm, 18 x 24 cm, 24 x 24 cm, 24 x 30 cm, 30 x 30 cm
Panoramic Modality Sensor technology Gray scale Sensor matrix Magnification Exposure time Exposure mode Radiological exam options
CCD 16384 - 14 bit 64 x 1536 pixels 1.27 4 to 16 sec. 12 anatomical settings Panoramic, segmented panoramic, maxillary sinus, LA TMJ x 2, LA TMJ x 4
X-Ray Generator and other specifications
Input voltage Unit dimensions Weight
60-80 kV (max), pulsed mode for 3D modality 2-15mA 140 kHz 0.5 mm (IEC 336) > 2.5 mm Al equivalent value 230 - 240 V - 50/60 Hz 100 - 110 - 130 V - 50/60 Hz 1158(L) x 1595(D) x 2378(max H) mm With cephalometric module: 2150 (L) x 1595 (D) x 2378 (max H) mm 160 kg, with cephalometric module 199 kg
CS 8000C / CS 8100 CS 9000 / CS 9300
CS 9000/CS 9300 Tube voltage KODAK 9500 Tube current Frequency Tube focal spot Total filtration
Units also available as 100-130 V / 60 Hz. Please contact your Carestream Dental sales representative for more information.
21
Digital extraoral radiography
CS 9300 / CS 9300C Digital Imaging System
The CS 9300 is the all-in-one imaging solution for dental professionals. Featuring a flexible field of view for truly adaptable 3D imaging, the unit offers unprecedented diagnostic capabilities, covering the widest array of clinical applications in the market. Easily collimate the field of view, adjust resolution, and change position according to your exam specifications. Regardless of which mode you select, the CS 9300 delivers the high image quality – while delivering optimized irradiation to the patient. Features and benefits ●● ●● ●● ●● ●●
●● ●●
Adjustable field of view size from 5x5cm to 17x13.5 cm Adaptable to all examination needs Compact and user-friendly unit design integrates easily into any practice Combines industry-leading panoramic imaging with powerful 3D imaging Full DICOM compliance; compatible with third-party software such as Nobel Guide, Simplant, and SureSmile Optional One-shot cephalometric imaging Variable Focal through 2D panoramic image
Now available in two versions: CS 9300 and CS 9300 Select Product
Cat. No.
CS 9300
5210646
CS 9300 Select*
5303573
CS 9300 3-year Care-Protect
5307418
CS 9300C
5210984
CS 9300C Select*
5303607
Ceph upgrade
5211016
CS 9300C 3-year Care-Protect
5307426
* CS 9300 Select is not upgradable to CS 9300
22
Digital extraoral radiography CS 9300
●● ●●
Voxel size: 90 to 500 FOV (cm): 5 x 5, 8 x 8, 10 x 5, 10 x 10, 17 x 6, 17 x 11, 17 x 13.5
CS 9300 Select
●● ●●
Voxel size: 90 to 300 FOV (cm): 5 x 5, 8 x 8, 10 x 5, 10 x 10
CS 9300 Select is not upgradable to CS 9300
Technical specifications 3D Modality Sensor technology Scan mode Scanning time Voxel size (μm) Field of view (cm) CS 9300 Field of view (cm) CS 9300 Select Reconstruction time
TFT Continuous and pulse 12-28 seconds (+/- 10%) 90 to 500 5 x 5, 8 x 8, 10 x 5, 10 x 10, 17 x 6, 17 x 11, 17 x 13.5 5 x 5, 8 x 8, 10 x 5, 10 x 10 Less than 2 minutes based on the recommended computer systems configuration requirements
Cephalometric Modality Sensor technology Gray scale Sensor matrix Magnification Exposure time Radiological exam options Acquisition format size (cm)
CCD 16384 - 14 bit 2100 x 2092 pixels 1.15 0.1 to 3.2 seconds Lateral, frontal AP or PA, oblique, submentovertex, carpus 18 x 18, 18 x 24, 24 x 24, 24 x 30, 30 x 30
Sensor technology Gray scale Sensor matrix Magnification Exposure time Radiological exam options
CS 8000C / CS 8100 CS 9000 / CS 9300
Panoramic Modality TFT 16384 - 14 bit 64 x 1536 pixels 1.22 4 to 16 seconds Panoramic, segmented panoramic, maxillary sinus
X-Ray Generator and Other Specifications Tube voltage Tube current Frequency Tube focal spot Input voltage Unit dimensions Weight
60-80 kV 2-15mA 140 kHz 0.7 mm (IEC 60336) 220 - 230 - 240 V - 50/60 Hz, 100 - 110 - 130 V - 50/60 Hz 1158 (L) x 1595 (D) x 2378 (max H) With cephalometric module: 2137 (L) x 1595 (D) x 2378 (max H) 160 kg, with cephalometric module 199 kg
Recommended PC requirements s. page 31
23
24
N/A
3D imaging
3D fields of view size
lll Best
●●●
●●●
●
●
Restorative
●
●
●
●
●●
●●
●●
●●●
●
●
●●●
●
●●●
●●●
*Please note bullets are simply a recommendation based on feedback from our thought leaders and users.
●
●
Prosthodontic
ll Better
●
●
Oral Surgery
l Good
●
●
Periodontic
●
●
●●●
CS 9000C
N/A
5 x 3.7 cm and ~7.5 x 3.7 cm
CS 9000 3D
Upgradeable
ü
ü
CS 9000C
ü
Upgradeable
ü
CS 9000 3D
Orthodontic
●
●●●
●●●
CS 9000
N/A
Upgradeable
Upgradeable
ü
CS 9000
●●●
●
●●●
CS 8000C
N/A
ü
ü
CS 8000C
Endodontic
Implantology
Routine panoramic examination Routine cephalometric evaluation
CS 8100
2D cephalometric
Applications
ü
CS 8100
2D panoramic
Modalities & Features
Comparative Matrix for Extraoral Range
●●
●●●
●●●
●●●
●●●
●●●
CS 9000C 3D
5 x 3.7 cm and ~7.5 x 3.7 cm
ü
ü
ü
CS 9000C 3D
CS 9300C Select
CS 9300 Select
●●●
●●●
●●●
●●●
●
●●●
●●●
●●●
●●●
●●●
●●●
●●●
●●●
●●●
Selectable 5 x 5 cm / 10 x 10 cm
Selectable 5 x 5 cm 10 x 10 cm
●●●
ü
ü
ü
CS 9300C Select
ü
Upgradeable
ü
CS 9300 Select
●●●
●●●
●●●
●●●
●
●●●
●●●
CS 9300
Selectable 5 x 5 cm 17 x 13.5 cm
ü
Upgradeable
ü
CS 9300
●●●
●●●
●●●
●●●
●●●
●●●
●●●
●●●
CS 9300C
Selectable 5 x 5 cm 17 x 13.5 cm
ü
ü
ü
CS 9300C
Extraoral imaging programs CS 8100 Digital Panoramic System Panoramic imaging
Standard panoramic
Child panoramic
TMJ x2 lateral
CS 8000C / CS 8100 CS 9000 / CS 9300
Segmented panoramic
TMJ x4 lateral
Maxillary sinus
2D+
25
Extraoral imaging programs CS 9000 Extraoral Imaging System Panoramic imaging
Cephalometric imaging
3D imaging
Standard panoramic
Lateral view, multiple formats
Child panoramic
Frontal AP Focused-field 3D program (5 x 3,7cm) Segmented panoramic
Frontal PA
TMJ x2 lateral
Submento vertex TMJ x4 lateral
Maxillary sinus
26
Carpus
Stitching 3D program (up to 8,5 x 6,6 x 3,7 cm)
Extraoral imaging programs CS 9300
10 x 10
• Implantology • Complex impactions • O ther cases involving both dental arches • Single TMJ assessments
• Double TMJ assessments
• Implantology, • Impactions • O ther cases involving one dental arch
• Single TMJ assessments
• Implantology • Complex impactions • O ther cases involving both dental arches
• • • • •
Orthodontics Complex treatment planning Orthognathic surgery Facial reconstruction Traumas Sinus and airway analyses
Orthodontics Complex treatment planning Orthognathic surgery Facial reconstruction Traumas Sinus and airway analyses
CS 8000C / CS 8100 CS 9000 / CS 9300
17 x 13.5 17 x 11
• • • • • •
5x5
• • • • • •
17 x 6 – TMJx2
RECOMMENDED APPLICATIONS
10 x 5
SAMPLE IMAGES
8 x 8 – TMJx1
REGION OF INTEREST
8x8
FOV
Endodontics Single implants Impactions TAD planning Any applications requiring a high level of detail (90μm)
27
Software
Carestream Dental Imaging Software The master software for all systems. Integrated 3D module.
Features and benefits ●● ●● ●● ●● ●●
●●
Top-quality and easy to use software Included as standard with all Carestream dental digital imaging products Serves as the control panel for all our systems Designed specifically for dental radiological diagnosis Can be used as a standalone program or integrated with practice management software No need to purchase additional licenses
The software controls all Carestream Dental products ●● ●● ●● ●● ●● ●● ●●
Product Carestream dental imaging software
28
Cat. No. 8557530
Particularly easy to use radiography software All features are accessible with just a few clicks 100% designed for user-friendliness Also ideal for novice PC users High image quality Network-ready Optional: DICOM support
Software
LOGICON Caries Detector Software Software for detecting caries even at an early stage.
Features and benefits
●● ●●
●● ●● ●●
A unique tool for detecting approximal caries at an early stage A software option for RVG digital radiography systems The software automatically highlights possible abnormalities on digital dental radiographs E-mail function allows sending of result screens to third parties Results can be saved to patient file Fully integrated with Carestream dental imaging software
Making caries diagnosis easier The Logicon software extracts image features and compares them to a database of known caries problems. Possible anomalies are thus marked automatically on the digital dental radiography images, allowing the dental surgeon to investigate the affected tooth and the tooth surface in more detail.
Functionality The Logicon software uses recognition algorithms based on laboratory data created in collaboration with a leading dental medicine institute. It automatically flags potential lesions on dental images and shows changes to the tooth density and the probability of lesions.
Product Logicon caries detector software
CDIS/LOGICON/ COMMUNICATOR
●●
Cat. No. 7417967
29
Software
Communicator Patient Software Communicator Patient Software helps dentist communicate, educate and gain informed consent. It includes a library of 140 animated sequences, 2000 still images and over 100 patient leaflets. Features and benefits ●●
●● ●● ●●
●●
●●
●●
●●
●●
Covers 167 animated topics - most conditions and procedures a dentist will deal with on a day-to-day basis Uses animations because being visual, they help the patient quickly understand what is being explained The animations last a maximum of a minute which speeds up the explanation time in the surgery An `interactive’ tool, where dentist can pause, skip forward/back and run the animations in slow motion controlling the speed of delivery to suit each patient No voice-overs, which means the dentist can use the appropriate language for each patient to ensure they understand. Includes 117 patient information leaflets which can be printed or emailed to the patient so they have information to support the explanation provided in the surgery The patient information leaflets are produced in MS Word, so they can be edited and branded to the practice The program includes over 2000 clinical photographs, but the dentist can add their own so they can show examples of work they have carried out in their practice The program also records which animations, leaflets and photos have been shown to the patient and this information can be printed or pasted into electronic PMS systems. This provides Medico-Legal protection for the dentist
Product Communicator Patient Software
30
Cat. No. 5160890
Recommended PC requirements For intraoral units: Intraoral Camera Family, RVG Family, CS 7400, CS 7600 CPU RAM Hard disc drive Graphic board Monitor Operating system Ethernet interface USB 2.0 CD/DVD drive
Viewing and acquisition 2 GHz Intel Dual Core 2 GB 1.2 GB for software installation 80 GB free space to use the software NVDIA board supporting Open Glide 1.2 with 256 MB of video RAM 17” or larger Minimum screen resolution of 1024 x 768, 32-bit color mode Windows XP Pro SP3 Windows 7 Pro 32/64 Bit 1 Gbit for LAN 3 ports DVD-ROM drive
For extraoral units: CS 8000C, CS 8100, CS 9000 Family, CS 9300 Family
CPU RAM Hard disk drive
Graphic board
Monitor
Viewing
Acquisition
2 GHz Intel Duo Core 4 GB 1.2 GB for software installation 250 GB free space to use the software 2D – PCI Express based card with min 512 MB 3D - NVIDIA based graphic card CUDA 3 compatible, minimum 200 CUDA cores 19’’ or larger Minimum screen resolution of 1280 x 1024, 32-bit color mode
2 GHz Intel Duo Core 4 GB 4 GB for software installation 250 GB free space to use the software 2D – PCI Express based card with min 512 MB 3D - NVIDIA based graphic card CUDA 3 compatible, minimum 200 CUDA cores 19’’ or larger Minimum screen resolution of 1280 x 1024, 32-bit color mode Windows XP Pro SP3 Windows 7 Pro 32/64 Bit CS 8100 – only Windows 7 Pro 32/64 Bit 1 Gbit for system link connection 1 Gbit for LAN CS 9300 - one free PCI slot required for Intel Pro 1000 GT PCI (delivered with the unit)
Operating system
Windows XP Pro SP3 Windows 7 Pro 32/64 Bit
Ethernet interface
1 Gbit for LAN
CD/DVD drive Backup Media Mouse
A DVD Burner drive is required Removable/portable, external hard disk drive A mouse with 2 buttons and a scroll wheel is required
CDIS/LOGICON/ COMMUNICATOR
IMPORTANT NOTE: It is mandatory to check that the PC system configuration is compatible with the PC system requirements. If necessary, please contact our customer service to get the latest PC system requirements. The computer and the peripheral equipment must conform to the IEC 60950 standard.
31
Looking for an imaging solution? We're confident we have the ideal solution for every practice! ●●
A full range of dental radiography and imaging systems
●●
100 years' experience in dental imaging
●●
In-house product development and manufacturing
●●
Worldwide dealer and service network
●●
The inventor of intraoral sensor technology
●●
High quality standards
Would you like to know more? www.carestreamdental.com
Finn og
Representeres i Norge av: Tonne Dental AS Trollåsveien 8, N-1414 TROLLÅSEN Tel. (+47) 66 89 20 50 - faks (+47) 66 89 20 51 E-post: salg@tonnedental.no
Carestream Dental © Carestream Health, Inc. 2012. RVG is a trademark of Carestream Health, Inc. iPhone® iPad®, and iPod touch® are trademarks of Apple Inc., registered in the U.S. and other countries.Rinn® is a registered trademarks and XCP-ORA™ is a trademark of DENTSPLY International, Inc. Simplant is a trademark of Materialise Dental. NobelGuide is a trademark of Nobel Biocare. SureSmile is a trademark of OraMetrix.
lik oss på
: