Watch it! Timber does not behave in the same way as inorganic materials such as steel and concrete. Here, Ishan Abeysekera highlights aspects of timber design that engineers used to designing in more traditional materials should be aware of.

54 | Timber 2023
The Smile – AHEC. London Design Festival 2016. Designed by ABA. Engineered by Arup. Photo: Dav Stewart and Jon Cardwell Timber structures Engineered timber

Timber: the material

Timber is a natural material harvested from trees. The microstructure of timber consists of tubes that transport nutrients and water through the tree, so it is helpful to think of timber as a bundle of straws. This structure makes timber much stronger parallel to the grain, for forces acting in the direction of straws, than perpendicular to the grain. Imagine trying to squash a bunch of tightly packed straws top down (axial loading), compared with how easy it would be to put a hand around the bundle and squeeze, bending them through their middles.

Since trees need branches, timber incorporates knots. Compared with ‘perfect’ straight-grained, knot-free timber, the tension strength of structural timber is more affected by knots in an off-axis grain direction than the compression strength. During axial (top-down) loading, a knot will be at the point of maximum stress wherever it is in the section. So, while the presence of a knot will always reduce axial capacity, its effect on the bending capacity will depend on where in the section it is. Knots at the edges of a timber beam will reduce bending strength significantly, while a knot at its centre will have little effect.

Duration of load also affects timber strength. At higher loads, creep behaviour of timber will not be stable (logarithmic with time) and will instead be unstable (exponential with time), creeping towards failure. So, engineers must apply load duration factors to keep the applied stress in real, long-term construction projects below documented strength levels that are measured in relatively short-term tests. When assessing design strength, the load case with the shortest load duration will govern the load duration factor for any given load combination.

Double-check sections and elements

Curved and tapered timber sections are readily available from several manufacturers. With curved elements, in addition to standard checks, engineers should carry out additional checks on tension perpendicular to grain, locked-in stresses due to glueing of curved laminates and non-linear section stress.

Tapered sections also require additional checks of shear forces and tension perpendicular to grain. >>

Timber 2023 | 55 www.bmtrada.com
“Since trees need branches, timber incorporates knots. This makes timber stronger in bending than in compression or tension.”
Timber structures Engineered timber

Calculate connection strength at concept

Connections are generally the weak points of timber structures. There is limited space to fit in screws, and slots for steel flitch plates can weaken the member. Design engineers who are used to adding reinforcement into a concrete connection, or welding on extra steel to make a connection work later in the design process, must learn to account for the nature of timber in an earlier design phase. If not, they risk having to increase member sizes to carry the connection forces.

Timber connections should be checked very early in the design and span to depth tables should be used with caution. As a rough rule, at concept design stage, beams should be sized to assume that connections have only 60% of the strength of the full timber cross-section.

Understand slip at timber connections

Timber connections are relatively flexible due to slip on the bolts, screws etc. This is due to oversizing of the hole and local crushing of the timber.

The stiffness of timber connections is highly variable and impossible to predict with any accuracy. Figure 1 provides just one example of just how variable a single lateral dowel type connection can be. So, the values in design codes should be used with extreme caution.

This has several implications:

• Connections significantly increase the deflection of trusses and portals – the increase is most easily calculated by hand using a virtual work method.

• When working with cross laminated timber (CLT) panels, connection stiffness dominates the flexibility of shear walls because the panels themselves are very stiff compared to the connections. Concrete cores make more sense for taller buildings.

• The uncertainty over connection stiffness means that, in indeterminate systems, it can be difficult to determine which path the loads will actually follow.

Minimise moment connections

Joints that transfer bending moment forces between a column and beam, or two or more beams, are known as moment connections. While not impossible, timber column to timber beam moment connections are expensive, difficult to achieve and have relatively low stiffness. Where possible it is often easier to avoid using this type of joint. Where two or more members cross in the same plane, moment connections are extremely difficult to achieve without a complex steel node. Most timber grillages – where one or more tiers of beams are superimposed at right angles to each other to disperse load over an extensive area – are in fact built as one-way spanning structures with short infill pieces in the secondary direction.

Avoid glueing on site

Reliable glueing of timber requires stringent conditions of temperature, moisture content, pressure and cleanliness. This is practically impossible to achieve under site conditions. There is also no non-destructive testing (NDT) that can be undertaken to confirm whether the glueing is adequate. Therefore, structures which rely on glueing on site should be avoided. In addition, even glueing in the factory should only be carried out by experienced fabricators. Where glueing of elements is carried out in the factory the engineer should check whether the manufacturer has adequate quality control measures in place.

Consider the cost of connections

In contrast to steel, where minimising the weight of steel will benefit the bottom line, an engineer must find alternative solutions to balance the influence of connections on the budget within the timber structural design. For example, >>

Timber 2023 | 57 www.bmtrada.com
Timber structures Engineered timber BSkyB Phase 2, Hounslow, London. Engineered by Arup. Photo: Hufton+Crow Figure 1: Stiffness variability of dowel type connections - Load-deformation behaviour and stiffness of lateral connections with multiple dowel type fasteners. INTER Conference 2018. Source: Jockwer. R. & Jorissen. A.

a truss – which will by definition have connections at nodes – will be materially the most efficient way to span a space, but it may well be cheaper to use a simply supported single spanning glulam beam. This solution will use more timber but has fewer connections.

Be cautious of indeterminate structures

Indeterminate structures with multiple possible load paths such as a propped cantilever beam, for example, make internal force calculation complex. This type of timber structure has uncertain relative stiffness of load paths due to the high flexibility, and variation within that flexibility, of its timber connections.

Timber elements and connections generally fail in a brittle way. Hence governing failure modes of timber structures may be brittle, and the lower bound theory of plasticity will not hold. This means that if a load path of an indeterminate timber structure with multiple load paths becomes overloaded, the load may not successfully redistribute to alternative load paths even if they have the capacity to withstand that additional load. In such a case, internal forces will not remain in equilibrium with the applied load, resulting in structural collapse.

Engineers need to be much more cautious about design than they would be with more ductile and forgiving materials. The simplest solution is to design timber structures with determinate load paths. Where this is not possible, the sensitivity of load distribution to variability of stiffnesses of different load paths should be tested, despite additional costs.

Dynamics governs floor depth

Because timber is lightweight, it is susceptible to higher accelerations and so floor depth can be governed by dynamics. So, it is important to either carry out a dynamic analysis early in the design process or inform the client that dynamics should be checked later and that results may affect the design. Engineers should note that modelling the entire floor plate is significantly beneficial when compared with modelling a few bays, as it will accurately capture the positive contribution of the larger mass of global modes.

Resistance to disproportionate collapse

Since timber is a brittle material, it does not have the ductility required for catenary action. Therefore, where local regulations require resistance to disproportionate collapse, tying is not a viable approach and element removal should be used instead.

It should be noted that element removal as means of achieving disproportionate collapse requirements is much more viable for timber than for more traditional materials because:

• Timber member design is governed by serviceability limit state (SLS) as opposed ultimate limit state (ULS) requirements. This leads to spare capacity at ULS, provided connections are also designed for the accidental load case.

• When compared with steel and concrete structures, the self-weight of timber is a smaller proportion of the total load, so the percentage reduction of total load for the accidental disproportionate loading case is much higher for timber structures. >>

Timber 2023 | 59 www.bmtrada.com
Timber structures Engineered timber Inside The Smile – AHEC. London Design Festival 2016. Designed by ABA. Engineered by Arup. Photo: Dav Stewart

Carefully model CLT with finite element analysis

A CLT panel can be modelled as 2D shell elements when applying finite element (FE) analysis. The designer should bear in mind the following:

• CLT floor systems are generally one-way spanning since half-lap joints along the long edges parallel to the main direction of span can generally only take in-plane forces, not out-of-plane bending and related shear.

• While most software allows for orthotropy to be modelled –different E and G values in different directions – it does not accurately model the stress distribution within the section due to the composite nature of CLT. Hence forces and moments should be obtained from the model, rather than stresses. Internal stresses in the CLT should then be calculated from these forces and moments using the methods provided in literature.

• When modelling CLT in software it is important to ensure that stiffness is modelled correctly for the directions being considered. The equivalent E value of CLT required to model the axial in-plane stiffness is different to the equivalent E value of CLT required to model the out-of-plane behaviour in the same direction.

Combining timber with steel: differential thermal expansion

Timber has a low coefficient of thermal expansion and is also a good insulator, therefore engineers can generally ignore thermal expansion. However, where timber is coupled with steel, it is important to consider the effects of the different thermal behaviour of the two materials. Contraction and expansion of the steel can lead to additional forces in both the timber and steel elements, as well in the connections.

In a bow truss, thermal expansion of the steel tie could lead to significantly increased bending stresses (and deflections) in the timber.

Differential vertical shortening

Where steel or concrete is used for the lateral stability system, but timber for the columns, there will be a differential vertical deflection between the timber structure and the core.

The analysis of this differential deflection, especially where the core is made from concrete, requires particular care. Timber and concrete have different stiffnesses, different creep moduli and different rates of creep. A staged construction analysis accounting for the different properties of timber and concrete will give the most accurate and economic results.

Since differential vertical shortening will generally give rise to SLS issues it is sensible to place the vertical timber columns

as far away from the core as possible. This will reduce the slope between the timber vertical structure and the concrete/ steel vertical structure.

Consult with specialists for acoustics, fire and durability

The acoustics, fire safety and durability of a timber structure are all impacted by the natural behaviours of the material and design engineers are advised to work with specialists to ensure these parameters are correctly managed.

Early consultation with an acoustic engineer is advisable when designing timber floors as they may need additional finishes for acoustic purposes due to their naturally low mass. The amount of timber exposed to fire is critical to safety, so consultation with a fire engineer when designing and selecting timber elements is advisable.

It is very important that timber is kept dry during its service life and during construction. If the moisture content of timber increases above 20% for an extended period, there will be a risk of fungal decay. A moisture control plan should be produced by the contractor to show their methodology for tracking and controlling the moisture content in the timber during construction, as well as mitigation measures if the moisture content starts to rise towards 20%. Waterproofing, ventilation and leak detection mechanisms should be included in the building design, to include adequate protection of engineered wood panels, timber end-grain, connections and ground contact timbers.

The durability of embedded steel connections should also be considered as they cannot be maintained. An example is steel flitch plates in a pool, coastal or external environment which are still exposed to the air but cannot be inspected or repainted.

Designing with timber

When managed correctly, timber is a remarkable material to work with. Design engineers willing to take the time to learn about this material, apply forethought during the early phases of the design concept, and work with experts for those areas needing specialist understanding will be well placed to deliver beautiful, durable and long standing timber structures. n