CDVI- katalog opreme

Page 1

Product Catalogue

ATRIUM Up to 10 Doors Access Control System Centaur Up to 2048 Doors Access Control System * Keypads & Card Readers Stand-Alone Systems Wireless Products Biometric Fingerprint Readers Proximity Cards and Badges Request-to-exit Devices Electromagnetic Locks Infrared Photocells * Per site Automatic Door Operator

A CDVI Group Company

cdvigroup.com


Hardware Simplicity Merging with Performance The AC22 is ATRIUM’s powerful 2-door main controller. Using AX22 door expansion units, 8 additional doors can be added to the AC22 main controller for a total of 10 doors. The AC22 main controller’s on-board Ethernet port with AES 256-bit encryption includes a user-friendly embedded web server enabling you to manage Users/Cards, lock or unlock doors, view system events and display controller information from any place in the world! The AC22 main controller includes a pre-assembled universal power supply and features an RS-485 auto-detection communication bus eliminating the need for confusing jumper and DIP switch settings. Keep RS485 cable expenditures to a minimum using common 4 conductor quad cable. Industry-unique and effortless card enrollment mode minimizes system start up and simplifies your life. Implement secure access control quickly without a computer!

Input Specifications Reader Inputs/Ports

2

Multi-purpose inputs

10 (20 using zone doubling)

Output Specifications

NEW

Lock outputs

2 (12Vdc)

Relay Outputs

2 Form C relays (Dry Contact) 5A/28Vdc

Electrical Specifications

AC22 I 2-Door Controller • Control 2 doors / readers (up to 10 doors with four AX22 2-door expanders)

Power input

85Vac to 264Vac, 50/60Hz

Supply Current

3.3A switching power supply

Battery backup

One 12Vdc, 4.5Ah or 7Ah, gel type battery

• Embedded Web Server • On-board Ethernet Port with AES 256-bit encryption • 1220m (4000ft) 4 conductor RS-485 expansion bus (No jumpers or DIP switches) • Auto-detect hardware modules • Quick and easy card enrollment procedure

Communication Auto-detect hardware modules (No DIP Switches) On-board Ethernet, RS-485 Bus expansion bus

• Totally fuseless system • Pre-assembled universal power supply (120V / 240V)

Size

• 1,000 users/cards • 100 Access Levels • 100 Schedules each supporting 100 time periods • 1,000 Event Buffer • 10 Partitions • Ultra fast firmware update (less than 10 seconds) • FREE Management Software • Wiegand & ABA Track II magnetic stripe compatible • Maintenance-friendly snap on terminal connectors • Comprehensive LED status indicators

2

c d v i . c a

Cabinet size

40 cm (H) x 32 cm (W) x 9 cm (D) 15.7” (H) x 12.6” (W) x 3.6” (D)

PCB dimensions

19.9cm (7.83”) x 18 cm (7.09”)

Environment

-22°C to 50°C (-4°F to 122°F)

On-board Protection Auxiliary outputs

1A (12Vdc) Fuseless protection

Manufacturing Access Control Since 1985


Hardware

and

Kits

Up to four AX22 door expanders increase the AC22 main controller’s capacity to 10 doors. Locate the AX22 anywhere on the 1220m (4000ft) 4 conductor RS485 communication bus. Effortless auto-detect technology identifies the AX22 on the communication bus. A preassembled universal power supply is included with every AX22 making this unit an industry leader in efficiency and simplicity.

AX22 I 2-Door Expander

NEW

• Control 2 doors / readers • Auto-detect hardware modules • 1220m (4000ft) 4 conductor RS-485 expansion bus (No jumpers or DIP switches) • Field-selectable lock outputs: Dry contact N.C/N.O. 28Vac/dc 5A -12V, 750mA (Supervised and protected) • Wiegand & ABA Track II magnetic stripe compatible • 10 Inputs (20 using zone doubling technology) • Comprehensive LED status indicators

AC22KITB I 2-Door Controller Kit

AX22KITB I 2-Door Expander Kit NEW

• • • • •

1 x AC22 (includes metal box with pre-assembled power supply) 2 x NANOPB (black proximity readers) 1 x Master card 1 x Programming card 1 x FREE Management Software

Manufacturing Access Control Since 1985

NEW

• 1 x AX22 (includes metal box with pre-assembled power supply) • 2 x NANOPB (black proximity readers)

c d v i . c a

3


Web Server

The innovative ATRIUM embedded web server is fast, simple and secure as can be. From any place in the world, you can do tasks like; user/card management, lock/unlock doors instantly, and view system events. The embedded web server provides instant results using any web browser, smart phone or iPad.

NEW

The Atrium web server allows you to:

4

Manage Users/Cards

View system events

Lock/Unlock doors and view real-time door status

View AC22 controller informations

c d v i . c a

Manufacturing Access Control Since 1985


T y p i c a l I n s ta l l at i o n AC22

2-door/reader controller

(WAN/LAN)

PC

Ethernet (IP)

Siren

Reader

Printer

Reader Expander network: Up to 1220 m (4000 ft) from the controller. «Star» and/or «Daisy Chain» Configuration

AX22

2-door/reader expander module

AX22

2-door/reader expander module

AX22

AX22

2-door/reader expander module

2-door/reader expander module

NEW

Atrium I Fast & Easy Card Enrollment Mode

Atrium System Features

Time is precious and we all need to be as efficient as possible. With ATRIUM’s straightforward Card Enrollment Mode, adding or deleting cards is easier than ever. Add or delete cards without using a computer. Two simple steps enable this feature and make this a fast and easy solution for you.

Main Features Embedded Web Server Users / Cards

Atrium I FREE Software with powerful features Intuitive door configuration settings, clear-cut access level programming, trouble-free user and card settings make advanced system programming a snap! For example, userfriendly and powerful Atrium schedules provide the capability to manage complicated tasks very easily.

Schedules

spanning many weeks or months requiring different time periods (day, evening and night) are quickly achieved with Atrium’s FREE advanced software.

Manufacturing Access Control Since 1985

Atrium 10 Doors System ✔ 1,000 / 1,000

Partitions

10

Inputs

100

Schedules /Periods Access Levels Event Buffer 2-Door Expander

100 / 100 100 1,000 4

c d v i . c a

5


Software

INTEGRATED ACCESS CONTROL

Version 5.1

INTEGRATED ACCESS CONTROL

LITE

Standard

Professional

Enterprise CS-AC-ENT*

Starter Pack

Sites

1

64

64

64

1

Serial Ports

1

1

1

4

4

Dial Up connection

Yes

Yes

Yes

Yes

Yes

TCP/IP connection

Yes

Yes

Yes

Yes

Yes

Cards

512

2,048 per site

8,196 per site

16,384 per site

512

Controllers

16

32 per site

64 per site

256 per site

1

Doors

16

128 per site

512 per site

2048 per site

8

Elevator Control

-

Yes

Yes

Yes

Yes

Elevator Cabs

-

64 per site

128 per site

512 per site

2

Floors per cab

-

64

64

64

64

Floor groups

-

128 per site

128 per site

128 per site

128

DVR Module

-

Yes

Yes

Yes

Yes

Visitor Management

-

Yes

Yes

Yes

Yes

Parking Management

-

Yes

Yes

Yes

Yes

Guard Tour

-

Yes

Yes

Yes

Yes

Asset Management

-

Yes

Yes

Yes

Yes

CS-AC-LITE

* Comes with a workstation license

CS-AC-STD

(131,072 max.) (2,048 max.)

(8,192 max.)

(4,096 max.)

(8,192 max.)

New

Guard Tour Feature

Live interactive guard tour allows check point validation using card readers, key switch inputs or data collectors. Includes live alarms for time violations and intuitive exception reports.

6

c d v i . c a

CS-AC-PRO*

(524,544 max.) (4,096 max.)

(32,768 max.)

(8,192 max.)

(8,192 max.)

(1,048,576 max.) (16,384 max.)

(131,072 max.)

(32,768 max.)

(8,192 max.)

FREE**

**

FREE from our web site, www.cdvi.ca Security dongle NOT required

Asset Management Feature

Why buy something that you already have? Keep track of your assets and save time and money. Quickly find who is in possession of your assets and for how long.

Manufacturing Access Control Since 1985


INTEGRATED ACCESS CONTROL

Software Modules FrontView - Live Interactive Floor Plans • Create or import floor plans with 64 interactive icons per plan • Complete library of interactive icons (or create your own) • Powerful event-based trigger actions • View, control and zoom into any area, device or object • Automatically display the area where an alarm occurs

Database Utility Manage large, complex database files with this simple

DVR Module

utility. Backup/Restore events and system configuration automatically or on demand with ease.

Centaur video (DVR) module lets you playback up to 60 seconds before and after a specific event. Capture and save video image (frame) in jpeg format during playback or live viewing.

FrontGuard - Visual Identification Display real-time video and compare the person accessing a door to the picture associated to the card in the database.

Parking Management Centaur Parking Management provides a parking

Locator

activity monitor. Quickly view how many parking spaces

Monitor the location (inside/outside) of each card holder in

are used, by which user and how many parking spaces

real-time. View/Print reports with a click of a button. Obtain

are available. Manually allocate or free parking spaces.

detailed card holder information with a double-click of the

Activate a “PARKING FULL” sign, when the parking

mouse button. Excellent for muster-point applications.

capacity is reached. Finally, generate reports on parking usage and

WavePlayer

activities.

Play an audible sound on any system event. Perfect for advising a system operator that an alarm condition exists even if he/she is not watching the monitor at all times.

Pro-Report - Report Generation module • User-friendly wizard for generating reports. • Create quick one-time reports, 125 pre-defined reports and 50 scheduled reports. • Multiple report types: System events, system configuration, time & attendance, absence, access, operator actions, custom card and input counting reports. • Export reports in multiple formats (ASCII, CSV, Excel, PDF, and more...) • Time & Attendance data acquisition.

Manufacturing Access Control Since 1985

Visitor Management Centaur’s Visitor Module can monitor and record all visitors coming to your premises. Preserves a complete record of all visitor activities and keeps each visitor’s information for

subsequent

visits.

Centaur’s Visitor Module will securely validate the comings and goings of all visitors.

c d v i . c a

7


INTEGRATED ACCESS CONTROL

S erver

to

Hardware

Controller Communication First CT-V900-A controller of a site

Optional Networked Workstation

E- bus N etwork Module Capacity To PC Centaur Server See diagram above Furthest modules can be up to 1220m (4000ft) away from the CT-V900-A

To other CT-V900-A controllers

Furthest controller can be up to 1220m (4000ft) away from first CT-V900-A

LCD Display CK-TRAK-L (Max. 8 per CT-V900-A)

8

c d v i . c a

Elevator Controller CA-A480-A (Max. 8 per CT-V900-A)

Relay Expander Module CA-A460-P (Max. 2 per CT-V900-A)

2-Door Expander Module CA-A470-A (Max. 3 per CT-V900-A)

Manufacturing Access Control Since 1985


INTEGRATED ACCESS CONTROL

Hardware

CT-V900-A I 2-Door Controller The CT-V900-A is at the heart of every Centaur access control system. The Centaur Server, hardware expander modules, multi-purpose inputs, card readers, keypads and outputs are connected directly to the CT-V900-A. Multi-controller systems are joined together via the RS-485 communication bus. Distributed database architecture allows each controller to make split-second decisions without the need of the server computer. Lightning-quick, robust and remarkable stability make the CT-V900-A the professional’s choice.

• Control 2 doors/readers per CT-V900-A (up to 8 using three CA-A470-A 2-door expander modules, see page 6) • On-board card database • 256 Schedules • 256 Access Levels • 2048 Event Buffer • Fully distributed database architecture (access decisions made locally) • Upgradable firmware - Upload firmware via the computer • E-Bus technology: expander modules can be up to 1220m (4000ft) from the CT-V900-A • Supports most common Wiegand formats, magnetic Stripe Track II ABA and 9 keypad formats, including BCD • Easy maintenance with snap-off terminal blocks • Lithium battery protection in case of complete power failure • Comprehensive LED status indicators

Output Specifications:

Electrical Specifications:

Lock outputs:

2 field-selectable (12 or 24Vdc)

Power input:

Relay Outputs:

2 Form C Dry Contact 5A/28Vdc

Supply current:

2.5A switching power supply maximum

Reader Outputs:

Six 50mA Open collector outputs

Battery backup:

Two 12Vdc, 7Ah, gel cell batteries

(Red/Green LEDs, Buzzer)

24Vac, 75VA or higher, 50/60Hz

Communication: Input Specifications:

Plug and play technology

Reader Inputs/Ports: 2

RS-485 E-Bus for expander modules, RS-485, TCP/IP, RS-232

Keypad Inputs/Ports: 2

or modem

Multi-purpose Inputs: 16 (using ATZ 2R/3R)

Physical Specifications:

On-board Protection:

Cabinet size:

39cm (H) x 33cm (W) x 10cm (D)

15.5” (H) x 13” (W) x 4” (D)

Auxiliary outputs:

2.5A (24Vdc), 1A (12Vdc & 5Vdc) fuseless protection

PCB dimensions:

24.5cm (9.65”) x 20.2cm (7.95”)

AC protection:

5A fuse

Environment:

5°C to 55°C (41°F to 133°F)

Battery reversal:

7A fuse

Manufacturing Access Control Since 1985

c d v i . c a

9


INTEGRATED ACCESS CONTROL

Hardware

CA-A470-A I 2-Door Expander Module Reduce field-wiring costs by running only one cable to the CT-V900-A. Reader, Keypad, Door Contact, REX device and Reader Outputs can be connected locally to the CA-A470-A by installing the expander module close to the doors. • Control 2 readers and/or keypads • Up to three CA-A470-A modules per CT-V900-A • 2 form C relays 15A/28Vdc, N.C./N.O. lock outputs • 4 Inputs (door contacts and REX devices) • 6 open collector, 50mA Sink, reader outputs • E-Bus connectivity to the CT-V900-A up to 1220m (4000ft) • Supports most common Wiegand formats, Magnetic Stripe Track II ABA, BCD keypad formats • Comprehensive LED status indicators

CA-A460-P I Relay Expander Module • Adds 7 form C relay outputs (5A/28Vdc) to the CT-V900-A controller • Up to 2 CA-A460-P modules per CT-V900-A controller • E-Bus connectivity to the CT-V900-A up to 1220m (4000ft) • Power Requirements: 12Vdc • Current consumption: 50mA (typical), 400mA (maximum)

CK-TRAK-L I Tracker LCD Display Specifically designed to work with Pro-Report’s time and attendance feature, the CK-TRAK-L acts as a “monitor” to display employee name, the date, time and “Punch In / Punch Out” to the employee/card user.

• Adjustable backlight and contrast • Display unit for time and attendance • 32-character LCD display (2 lines – 16 characters each) • Can be used with Anti-passback applications to display user locations • Power Requirements: 9 to 16Vdc • E-Bus connectivity to the CT-V900-A up to 1220m (4000ft) • LCD: Super Twisted Nematic display (STN) Wide viewing angle • Up to 8 CK-TRAK-L modules per CT-V900-A controller

10

c d v i . c a

Manufacturing Access Control Since 1985


INTEGRATED ACCESS CONTROL

Hardware

CA-A360-A I RS-232 to RS-485 Converter CA-A360-USB I RS-232 and/or USB to RS-485 Converter The CA-A360-A and CA-A360-USB converters, installed between the Centaur Server and the CT-V900-A controllers, allow a “daisy-chain” configuration thus extending the total connection distance to 1220m (4000ft). The LEDs provide easy and visual identification of the module’s Power and communication status. • Converts RS-232 protocol to RS-485 protocol (CA-A360-A) • Converts RS-232 or USB protocol to RS-485 protocol (CA-A360-USB) • Allows a total of up to 1220m (4000 ft) of RS-485 cabling • Work with UTP cable (Cat 5) • Transmit, Receive and Power status LEDs • Power Requirements: 12Vdc or via USB power CA-A360-A

CA-A360-USB

• Current consumption: 100mA max • Operating temp: -10°C to 55°C (14°F to 131°F)

CA-A370-P I RS-485 Network Hub Enables “star” type network configuration of the RS-485 bus. Excellent for large or multi-floor buildings/sites where a “daisy chain” RS-485 configuration is not feasible. Locate the CA-A370-P in a central location along an existing RS-485 network and run 4 individual RS-485 networks out to the controllers or expander modules. • RS-485 “star” configuration is a snap • Provides a higher network isolation from noise • Saves on wiring costs • LED indicators for power, network and port activity • Create 4 independent RS-485 networks from 1 RS-485 network • Connects to the CT-V900-A RS-485 and E-Bus communication ports • Connect controllers or expander modules up to 1220m (4000ft) from the hub • Power Requirements: 10 to 14.6Vdc • Current consumption: 190 mA typical • Operating temp: -10°C to 55°C (14°F to 131°F)

CA-ETHR-A I TCP/IP – RS-232 Converter Minimize field wiring costs by using existing LAN/WAN networks. We have the solution at a very aggressive price. This unit enables RS-232 serial devices such as the CT-V900-A to communicate over a LAN/WAN network. • Converts TCP/IP protocol to RS-232 • Simple programming & setup • Static IP Addressing • RJ-45 connection to the LAN • LED status indicators • RS-232 serial connector supplied • Supports TCP/IP, HTTP, ICMP and ARP protocols

Manufacturing Access Control Since 1985

• Ethernet Compatibility: Version 2.0/IEEE 802.3 • 10 MBPS – Half Duplex • 9600, 19200 and 38400 baud rates • Serial format: 8 data bits, 1 Stop bit, No Parity • PCB Dimensions: 10cm x 6.4cm (4in x 2.5in)

c d v i . c a

11


INTEGRATED ACCESS CONTROL

Hardware

CA-A480-A I Elevator Controller Connected to the CT-V900-A controller’s expander bus, each CA-A480-A can control up to 16 floors. The CA-A480-A floor control relays can be interfaced directly with an elevator’s floor control buttons. When a valid card is presented, the appropriate floor control relays will become enabled allowing the cardholder to select the desired floor. • 16 Form “C” floor control relays (15A/28Vdc, N.C./N.O.) • 1 Fire control input + 1 Tamper input • Control up to 64 floors and 2 elevator cabs • Destination reporting (requires CA-A482-P) • E-Bus connectivity to the CT-V900-A up to 1220m (4000ft) • Backup battery with selectable battery charge current • On-board 12Vdc power supply • Fully supervised (tamper, low battery and AC failure) with LED display • Up to 8 CA-A480-A controller per CT-V900-A controller

CA-A482-P I Destination Reporting Module Connected on top of the CA-A480-A, the DRM has 16 Floor Selection inputs, one for each floor control relay of the CA-A480-A elevator controller. Once a card is presented, the user can only select one floor. Once the floor is selected, all other floor selection buttons are de-activated. The user must present his card again in order to select another floor. Each card swipe and individual floor selection is recorded by the system. • Connects directly onto the CA-A480-A elevator controller • One-card swipe, one-floor operation • User must present a valid card to select a floor button. • 16 floor-selection inputs and LED indicators • Records Valid and Invalid floor selections • Power input: 5Vdc • Current consumption: 28mA (typical), 108mA (max) • DC input activation: 15Vdc (minimum), 165Vdc (max) • Connection method: 14-way Flat Cable to CA-A480-A

CA-A110-P I Lock Control Module The CA-A110-P has been designed to reduce installation time and simplify the connection of electromagnetic locks or in conjunction with door strikes. It is directly inserted into the CT-V900-A’s lock terminals. • Simplifies the installation of dual-locking doors (2 mag locks or combination of a mag lock and a door strike) • Lock outputs: 2 form C relays rated at 5A/12Vdc, N.C./N.O. • 2 relay status LEDs • Connects directly to the CT-V900-A lock output terminals • Current consumption: 100mA

12

c d v i . c a

Manufacturing Access Control Since 1985


INTEGRATED ACCESS CONTROL

Kits 2-DoorMKIT I 2-Door Master Kit • 1 x CT-V900-A with metal box • 2 x DGLP FN WLC26 proximity readers • 1 x 8-Door StarterPack Centaur software • 1 x DB9FF10 Female-Female DB9 10 meter cable • 1 x CDVI150 Transformer (Can supply 1 x CT-V900-A and 3 x CA-A470-A) • Kit without metal box: 2-DoorMKIT-NB

4-DoorMKIT I 4-Door Master Kit • 1 x CT-V900-A with metal box • 1 x CA-A470-A with metal box • 4 x DGLP FN WLC26 proximity readers • 1 x 8-Door StarterPack Centaur software • 1 x DB9FF10 Female-Female DB9 10 meter cable • 1 x CDVI150 Transformer (Can supply 1 x CT-V900-A and 3 x CA-A470-A) • Kit without metal box: 4-DoorMKIT-NB

8-DoorMKIT I 8-Door Master Kit • 1 x CT-V900-A with metal box • 3 x CA-A470-A with metal box • 8 x DGLP FN WLC26 proximity readers • 1 x 8-Door StarterPack Centaur software • 1 x DB9FF10 Female-Female DB9 10 meter cable • 1 x CDVI150 Transformer (Can supply 1 x CT-V900-A and 3 x CA-A470-A) • Kit without metal box: 8-DoorMKIT-NB

2-DoorEKIT I 2-Door Expander Kit • 1 x CA-A470-A with metal box • 2 x DGLP FN WLC26 proximity readers • Kit without metal box: 2-DoorEKIT-NB

Manufacturing Access Control Since 1985

c d v i . c a

13


Transformers / Readers CDVI150 I 150VA Transformer • Secondary voltage: 16Vac and 24Vac

• Secondary screw wiring terminals

• Volt-ampere: 150VA (75VA at 16Vac + 75VA at 24Vac)

• Weight: 7 Lbs (3.2 Kg)

• Primary voltage: 120V (Fuse protected) • Frequency: 60Hz

NANOPB I Mini Wiegand Proximity Reader

• Available in 200VA: CDVI 200, (100VA at 16Vac + 100VA at 24Vac) CDVI200 supply up to 2 CT-V900-A (24Vac) and Up to 6 CA-A470-A (16Vac)

NANOPW I Mini Wiegand Proximity Reader

• Reads CDVI Wiegand 26-bit card encoding

• Reads CDVI Wiegand 26-bit card encoding

• 10 cm (4 in) read range

• 10 cm (4 in) read range

• Illuminated card reader (Blue, green and red).

• Illuminated card reader (Blue, green and red).

• Audible feedback NEW

• PCB sealed in epoxy

• Operating temp.: -30°C to 60°C

• Power requirements: 12Vdc

• Power requirements: 12Vdc

STARPW I Mullion Proximity Reader

• Reads CDVI and most popular 26-bits Wiegand card encoding

• Reads CDVI and most popular 26-bits Wiegand card encoding

• 10 cm (4 in) read range

• 10 cm (4 in) read range

• Illuminated card reader (Blue, green and red).

• Illuminated card reader (Blue, green and red).

• Audible feedback

• Audible feedback

• PCB sealed in epoxy • Operating temp.: -30°C to 60°C

NEW

• Power requirements: 12Vdc

SOLARPB I Multi-Technology Proximity Reader

NEW

c d v i . c a

• PCB sealed in epoxy • Operating temp.: -30°C to 60°C • Power requirements: 12Vdc

SOLARPW I Multi-Technology Proximity Reader

• Reads CDVI and most popular 26-bits Wiegand card encoding

• Reads CDVI and most popular 26-bits Wiegand card encoding

• 10 cm (4 in) read range

• 10 cm (4 in) read range

• Illuminated card reader (Blue, green and red).

• Illuminated card reader (Blue, green and red).

• Audible feedback

• Audible feedback

• PCB sealed in epoxy • Operating temp.: -30°C to 60°C • Power requirements: 12Vdc

14

• PCB sealed in epoxy

• Operating temp.: -30°C to 60°C

STARPB I Mullion Proximity Reader

NEW

• Audible feedback NEW

NEW

• PCB sealed in epoxy • Operating temp.: -30°C to 60°C • Power requirements: 12Vdc

Manufacturing Access Control Since 1985


K e y pa d s & C a r d R e a d e r s Galeo/W I 26-Bit Wiegand Back-Lit Keypad

KCP/BP/26W I 26-Bit Wiegand Keypad

• Heavy-duty ZAMAK cast alloy (Zinc, Aluminium, Magnesium and Copper)

• Stainless Steel construction • 26-Bit Wiegand output • Call button

• Eye-catching bright blue backlighting

• Potted Electronics • Integrated Piezo/Buzzer

• Potted electronics

• Power requirements: 12Vdc

• Integrated Piezo/Buzzer • Power requirements: 12Vdc

DGLP WLC26 and DGLP FN WLC26 Multi-Technology Wiegand Proximity Reader

DGLI WLC26 and DGLI F WLC26 Multi-Technology Wiegand Proximity Reader

DGLP FN WLC26

DGLI F WLC26

• Rugged polycarbonate • 26-bit format Wiegand output,

• Dust/Weather/Vandal resistant

• Compatible with CDVI, Centaur (Position Technology) and most 26-bit format cards.

• 26-bit format Wiegand output,

• Up to 8cm (3.5 in) read range • Potted electronics

DGLP WLC26

• Stainless steel proximity reader

• Compatible with CDVI, Centaur (Position Technology) and most DGLI WLC26 26-bit format cards. • Up to 8cm (3.5 in) read range

• Red/Green LEDs and Buzzer

• Potted electronics

• Power requirements: 12Vdc

• Red/Green LEDs and Buzzer • Power requirements: 12Vdc

DGLP60WLC I Wiegand Long Range Reader

KCPROXWLC I Proximity card reader and keypad

• 60 cm (23.5 in) read range

• Vandal proof housing

• Selectable CDVI Wiegand output: 26, 30 or 44 bit format

• Backlit keys

• Compatible with CDVI, Centaur (Position Technology) and most 26-bit format cards. • Red/Green LEDs and Buzzer • Operating temp.: -30°C to 60°C

• Compatible with CDVI, Centaur (Position Technology) and most 26-bit format cards. • Red/Green LEDs and Buzzer • Operating Temperature : -25°C to 70°C

• Power requirements: 12Vdc

DGLP M WLC I Mifare® Proximity Reader • Rugged polycarbonate • 26-bit format Wiegand output • Up to 8cm (3.5 in) read range • Potted electronics • Red/Green LEDs and Buzzer • Power requirements: 12Vdc

Manufacturing Access Control Since 1985

DGLI M WLC I Mifare® Proximity Reader • Stainless steel proximity reader • Dust/Weather/Vandal resistant • 26-bit format Wiegand output • Up to 8cm (3.5 in) read range • Potted electronics • Red/Green LEDs and Buzzer • Power requirements: 12Vdc

c d v i . c a

15


Cards CS I Standard clamshell card • CDVI 26-bit Weigand format • 85 mm x 54 mm x 1.8 mm • 125 kHz proximity card • Sequentially generated decimal card numbers (printed on each card) • Also available with encoding for PosiProx, PosiPin and PosiXtend readers: 702

and

Tags

Proximity Cards and Badges These proximity cards and tags are randomly generated hexadecimal card numbers BP: CPE: CP: PPC: PP:

Elegant leather key ring tag Standard clamshell card Thin card for printing photos and text (ISO) Rugged gray polycarbonate key ring card Stylish black polycarbonate tear drop card, available for Mifare® proximity reader: PVP CPE

CP

PPC

BTAG I Blue Key Tag • CDVI 26-bit Weigand format

PP

BP

• Polycarbonate tag • 40 mm x 33 mm x 4 mm • 125 kHz proximity card • Sequentially generated decimal card numbers (printed on each card)

LEDTAG I Solar LED light with built-in key tag • Built-in CDVI 26-bit Weigand format • High-intensity LED technology

• Also available with encoding for PosiProx, PosiPin and PosiXtend readers: 704

ISO I Printable ISO Card

• Excellent for service technicians • Rechargeable Lithium battery

METAL1 I Proximity Key Holder Steel Tag • High resistant steel tag

• CDVI 26-bit Weigand format

• Tag sealed in epoxy

• Printable on both sides

• CDVI 26-bit Weigand format

• 85 mm x 54 mm x .8 mm

• 125 kHz proximity card

• 125 kHz proximity card

• Also available:

• Sequentially generated decimal card numbers (printed on each card)

METAL: Mifare® 13.56 Mhz METAL2: Tag encoding for PosiProx, PosiPin and PosiXtend

• Also available with encoding for PosiProx, PosiPin and PosiXtend readers: 706

DISCTAG I Mini PVC Tag • CDVI 26-bit Weigand format • Adhesive on one side • 20 mm (Dia) x 1.5 mm (H) • 125 kHz proximity card • Sequentially generated decimal card numbers (printed on each card) • Also available with encoding for PosiProx, PosiPin and PosiXtend readers: 708

16

c d v i . c a

readers

CMPP I Card Enrolment Unit Cards are automatically enrolled in CENTAUR database. Simply present the badge in front of the unit and the code is transmitted into the PC in the cardholder file. Delivered with a proximity reader head. It is possible to add other modules. Other reader heads sold separately: • MA: “Dallas” type reader • MI: infrared • MR: RF receiver • MM: magnetic stripe

Manufacturing Access Control Since 1985


S ta n d -A lo n e S y s t e m s PROMI ECO I 1-Door Stand-Alone Keypad

C2R100/US I Keypad with Built-in Controller • Fluorescent keypad keys

• Built-in controller

• Stainless steel faceplate

• 100 user codes (3 to 8 digits)

• Mounts on a singlegang box

• Request-to-exit input

• 150 user codes

• Easy setup

• 3 to 6 digit codes

• Audible and visual feedback

• Programmable audible feedback buttons

• Power requirements: 12Vdc/ac

• Up to three outputs (2 relays & 1 open-collector)

Galeo I Back-Lit Keypad with Remote Controller

KCIEN/SBP I Illuminated Keypad with Built-in Controller

• 100 user codes (4 or 5 digits)

• Illuminated stainless steel keypad

• Request-to-exit input

• 100 user codes (4, 5 or 6 digits)

• Programmable audible feedback buttons

• 2 form C outputs (8A/250V), timed (1 to 99 sec.) or latched

• Power: 12/48Vdc or 12/24Vac

• Audible feedback buttons

• GALEO: 1 relay output GALEO2: 2 relay outputs GALEO3: 3 relay outputs

• Request-to-exit input • Potted electronics • Power requirements:

• Timed (1 to 99 sec.) or latched output

12/24 Vac or 12/48 Vdc • Available with call button (Door bell/ Chime): KCIEN

PROFIL100EC I Keypad with Remote Controller

KCP/BP I Remote Keypad

• Illuminated stainless steel keypad

• Remote keypad for PROMI or DG1

• 100 user codes (4 or 5 digits)

• High security stainless steel construction

• 2 form C outputs (8A/250V), timed (1 to 99 sec.) or latched

• Call button

• Audible and visual feedback

• Audible feedback buttons

• Request-to-exit input

• Programming made from the “host” keypad.

• Potted electronics

• Power requirements: 12Vac/dc

• Power requirements: 12/24 Vac or 12/48 Vdc

PROMI / DG1 I 2-Door Stand-Alone Keypad • Surface mount keypad • 500 user codes (5 digits)

• All programming stored in nonvolatile EEPROM memory

• Audible & Visual feedback

• Power requirements: 12Vac/dc

• 1 form C output and 1 N/O output, timed (1 to 99 sec.) or latched

• Optional remote keypad: KCP/BP

• Consumption: 120mA

• 2 request-to-exit inputs

PROMI

DG1

Manufacturing Access Control Since 1985

c d v i . c a

17


S ta n d -A lo n e S y s t e m s PROMI500 / DGPROX I 1-Door Stand-Alone Proximity Reader and Keypad • 500 users (proximity card and/or codes)

• 1 request-to-exit input

• 3 operating modes:

• 1 form C, door relay output (3A/125V)

- Mode 0: card and code

- Mode 1: card only

- Mode 2: card or code

• 1 form C, alarm relay output (3A/125V) • Power requirements: 12VAC/DC

• Audible & Visual feedback PROMI500

• Tamper switch

DGPROX

PROMI1000 I 1-Door Stand-Alone Proximity Reader and Keypad • 1000 users (proximity card and/or codes)

• Real-time event printing

• 3 operating modes: - Mode 0: card and code - Mode 1: card only - Mode 2: card or code

• 1 request-to-exit input & 1 Tamper switch

• Supports anti-passback • Audible & Visual feedback • 1 form C, door relay output (3A/125V)

• 1000 event memory

• 1 form C, alarm relay output (3A/125V)

• 16 holiday schedules

• Power requirements: 12Vac/dc

DGLP / DGLP/FN I Polycarbonate Proximity Reader

DGLI / DGLI/F I Stainless Steel Proximity Reader

DGLP/FN

DGLI/F

DGLP

• Remote readers for PROMI1000, PROMI500 and DGPROX

• Remote readers for PROMI1000, PROMI500 and DGPROX

• Surface mount

• Vandal resistant

• Up to 50M (164ft) between the reader and the controller

• Up to 8cm (3.5 in) read range

• Up to 50M (164ft) to the controller

• Up to 8cm (3.5 in) read range

DGLI

• LED visual feedback

• LED visual feedback • Power requirements: 12V ac/dc

• Power requirements: 12V ac/dc

SEF2405 / 2410 / 2420 /2420AVN I Infrared Photocell Detector • Power requirements: 12/24Vdc • Operating temperature: -20°C / +55°C • SEF2405: Flat infrared photocell, range: 5M (16.5ft) • SEF2410: Flat infrared photocell, range: 10M (33ft) • SEF2420: Adjustable infrared photocell, range: 20M (66ft) SEF2405 and SEF2410

18

c d v i . c a

SEF2420

SEF2420AVN

• SEF2420AVN: Vandal-proof adjustable infrared photocell, range: 20M (66ft)

Manufacturing Access Control Since 1985


Electromagnetic Locks V3S I 300kg (660lbs) Holding Force

P400RN I 400kg (880lbs) Holding Force

• Surface mount installation

• Retrofit electromagnetic door handle

• Power requirements: 12/24Vdc

• Complete Aluminium housing

• Current Draw: 550mA @ 12Vdc, 270mA @ 24Vdc

• Power requirements: 12/24Vdc

• Zinc EM surface and anodized aluminum housing • Flush mount installation: V3E

• Current Draw: 560mA @ 12Vdc, 270mA @ 24Vdc • 40 cm (H) x 12,6 cm (W) x 6,8 cm (D) (15,75 in x 5 in x 2,7 in)

• Optional monitoring sensor: V3SR

V5S I 500kg (1100lbs) Holding Force

V5EI I 500kg (1100lbs) Holding Force

• Visual feedback (red & green)

• Flush mount installation

• Surface mount installation

• Sliding door applications

• Out-In-swinging door applications

• Power requirements: 12/24Vdc

• Power requirements: 12/24Vdc

• Current Draw: 550mA @ 12Vdc, 270mA @ 24Vdc

• Current Draw: 550mA @ 12Vdc, 270mA @ 24Vdc • 268mm (H) x 75mm (W) x 40mm (D) (10.5in x 3in x 1.5in)

• 266mm (H) x 66mm (W) x40mm (D) (10.5in x 2.5in x 1.5in) • Stainless steel

• Optional monitoring sensor: V5SR

VSI5R I 500kg (1100lbs) Holding Force

CZ3000 I 1500kg (3300lbs) Holding Force

• Exterior applications & High-traffic areas

• Shearlock

• Power requirements: 12/24Vdc

• Power requirements: 12/24 Vdc

• Current Draw: 550mA @ 12Vdc, 280mA @ 24Vdc • 220mm (H) x 64mm (W) x 40mm(D) (8.6in x 2.5in x 1.5in) • Optional monitoring sensor: VSI5R

• Self-Aligning • Current Draw: 600 mA @ 12 Vdc and 300 mA @ 24 Vdc • Compact mortise-mount • 206mm (H) x 30mm (W) x 32mm (D) (8” x 1.2” x 1.25”) • Optional surface mount kit (KCZ 3000)

PWM25PSR I 800kg (1750lbs) Holding Force

PWM25ER I 800kg (1750lbs) Holding Force

• Shearlock door handle

• Shearlock flush mount installation

• Patented self-aligning mechanism

• Patented self-aligning mechanism

• Input voltage: 12, 24 or 48V dc

• Input voltage: 12, 24 or 48V dc

• Current Draw: 460mA@12Vdc,

• Current Draw: 460mA@12Vdc,

230mA@24Vdc & 150mA@48Vdc

230mA@24Vdc & 150mA@48Vdc

• Available in black: PWM25PSR/RAL NOIR

• Surface option: PWM25SR

Manufacturing Access Control Since 1985

c d v i . c a

19


Wireless CDVI high quality RF transmitters/receivers are the perfect solution to operate parking lot gates, garage doors, handicap doors, etc. These 433.92 MHz radio frequency systems offer longer range up to 250m (820ft), less interference jamming and excellent reliability. Licensed KeeLoq® Rolling Code technology ensure ultra-secure transactions. SETR2641AM1 I 1-Channel Mini Transmitter

SETR2641AM2X I 2-Channel Mini Transmitters

• Elegant & easy to carry • Range up to 200 m (650 ft) • 60 x 36 x 16mm (2.35 x 1.4 x 0.6in) • Two lithium batteries (CR2016)

• Heavy-duty construction

NEW

• Range up to 200 m (650 ft)

NEW

• Elegant & easy to carry

These transmitters are also available with CDVI or HID built-in proximity tag

• Available in: Black (SETR2641AM2.K), (Dark Gray (SETR2641AM2.N), Red (SETR2641AM2.R), Blue (SETR2641AM2.B) and Burgundy (SETR2641AM2.C) • 60 x 36 x 16mm (2.35 x 1.4 x 0.6in) • Two lithium batteries (CR2016)

S2TR2641E2 I 2-Channel Transmitters S2TR2641E4 I 4-Channel Transmitters • Palm-size transmitters 83 x 48 x 16mm (3.25 x 1.9 x 0.6in)

• Casing: aluminum and black polycarbonate • Range up to 200 m (650 ft)

• Ergonomic & stylish design

• 70 mm x 40 mm x 10 mm (2.75 in. x 1.57 in. x 0.4 in.)

• One 12V lithium battery (L1028 or 23A)

FKT2641E1 I 1-Channel Key Free Transmitter • Outdoor installations ( IP55). • Frequency : 433,92 MHz. • Encoding : Keeloq® Hopping code • Supply : 3 V Lithium battery (CR123A) • Range up to 400 m (1300 ft) • Dimensions: 90 x 60 x 25 mm

c d v i . c a

• Innovative and heavy-duty construction

• Range up to 250 m (820 ft) • Rugged & durable

20

S7TR2641E4 I 4-Channel Transmitters

• One lithium battery (CR2032)

SELWR433 I Wiegand Wireless Receiver • 26-bit Wiegand output • Power: 12 or 24V (AC or DC) • Dimensions: 105 x 45 x 28mm (4.3 x 1.75 x 1.1in) • Compatible with Centaur or any 26-bit Wiegand-capable systems

Manufacturing Access Control Since 1985


Wireless SEL2641R433I 2-Relay Stand-Alone Wireless Receiver • Up to 85 transmitter keys • 1 NO relay + 1 NO/NC relay (24VA) • Self-learning memorization • Standard pulse output relay • Power requirements: 12/24Vac/dc • Dimensions: 105 x 45 x 28 mm (4.3 x 1.75 x 1.1in) • Available with pulse, latched or delayed relay output: SEL2641R433IP

SEL2641R433-K8P I Multi-user Receiver • 800 transmitters • Programming through a PC with optional software kit (SEL2641KITP8) or with a master transmitter S2TR2641E2M • 1600 transmitter model: SEL2641R433-K16P

SEL2641R433-Z4 I 4-Relay Stand-Alone Receiver • Up to 85 transmitter keys • 2 NO relay + 2 NO/NC relay • Standard pulse output • Relay 4 supports latched output • Voltage: 12/24Vac/dc

SEL2641MEMB I Plug-in Memory Back-Up • Use to Upload/Download all programming of the multi-user receiver SEL2641R433K8P • Also available for the multi-user receiver SEL2641R433-K16P: SEL2641MEMB16

Manufacturing Access Control Since 1985

SEL2641R433IP5 2-Relay Stand-Alone Wireless Receiver • Up to 500 users with 1 or 2 channel transmitters • 1 NO relay + 1 NO/NC relay (24VA) • Pulse, latched or delayed relay output • Power requirements: 12/24Vac/dc • Dimensions: 105 x 45 x 28 mm (4.3 x 1.75 x 1.1in)

SEL2641R433C2P 2-Relay Stand-Alone Power Wireless Receiver • Up to 85 transmitter keys • 1 NO relay + 1 NO/NC relay (230Vac) • Relays with Pulse, latched or delayed operating mode. • Power requirements: 12/24Vac/dc • 4 relay model: SEL2641R433C4P

SEA433 I 433Mhz Tuned Antenna • Increase reception and/or range • 11.5ft (3.5m) coaxial cable (RG 58) included • “L”-shaped bracket for wall-mounting

SEL2641-KITP8 Software Kit for Multi-User Receiver • Kit for SEL2641R433-K8P • Includes: Software (PCCOM), USB driver, all necessary cables and a plug-in memory back-up • Also available for multi-user receiver SEL2641R433-K16P: SEL2641-KITP16

c d v i . c a

21


D o o r O p e r at o r s DWPS106ACD Automatic door operator with articulated arm (Pushes the door)

Automatic door operator suitable for single doors, inward or outward opening, left or right handed and with fail safe or fail secure locking.

DWPS106SCD Automatic door operator with sliding arm (Pulls the door)

• Integrated wireless receiver (includes 1 transmitter: S2TR2641E2) • Adjustable pause time • Stand-alone or connects to an access control system • Obstacle detection • Operating Modes:

- Free Gate - Automatic - Always open

Outward opening

Inward opening

DWPS106ACD

DWPS106SCD

• Electronic calculation of speed and movement • Includes backup battery

System identification Ref.

Description

Input Voltage (Vac)

Dimensions LxHxD

Door Weight (kg)

Door Width (m)

Consumption (mA)

DWPS106ACD

Door operator with an articulated arm for outward opening door (pushes the door)

16Vac

509 x 90 x 110 (20 x 3.5 x 4.3 in.)

100kg (220 Lbs)

1 meter (3,28 ft)

200mA

DWPS106SCD

Door operator with a sliding arm for inward opening door (pulls the door)

16Vac

509 x 90 x 110 (20 x 3.5 x 4.3 in.)

100kg (220 Lbs)

1 meter (3,28 ft)

200mA

Compatible wireless transmitters: Ref. S2TR2641E2

22

Description or

E4

SETR2641AM2

2 or 4-channel transmitter

SETR2641AM2

2-channel Mini transmitter (Available color: black, blue, red, dark grey or burgundy)

S7TR2641E4

4-channel robust & innovative transmitter

c d v i . c a

S2TR2641E2 & E4

S7TR2641E4

Manufacturing Access Control Since 1985


B i o m e t r i c s & REX DGID/W/US I Wiegand Fingerprint Reader

CABAPROX/W I Biometric & Mifare® Technology

• 26, 30 or 44-bit wiegand output • Self cleaning sensor area

• Fingerprint reader + Mifare® proximity reader

• 3 LED’s to indicate sweeping direction

• Fingerprint template stored in the badge/card

• Upgradable firmware

• Limited fingerprints by software database

• Tamper switch

• 26, 30 or 44-bit wiegand output

• Power requirements: 12V ac/dc

• Current consumption: 450mA

• Work in stand-alone mode (Stores up to 350 fingerprints)

• Available stand-alone model: CABAPROX

PCMB I Mifare® tag programmer for Cabaprox

USB SCANNER I Fingerprint enrolment unit • High quality fingerprint

• Compatible with all Mifare® tags

• Self-cleaning sensor

• Multi-site

• Automatic finger detection

• Fingerprint programmer

• Drivers for Microsoft Windows

• Includes:

2000, XP and Vista • Encrypted connection with PC

EXIT-BLP I Request-to-Exit Press Button

DEEE & RoHS

- LCD display - USB Scanner - DB9 cable - Software - AC power transformer

• Ergonomic design

CE Certification Environmental tests : Salt spray

• NO and NC contact outputs with 2 separate contacts, DPDT • Stainless steel plate • Heavy duty switch • Mounts on a single gang box (EXIT-BLP)

IP68

EXIT-BLP

EXIT-BSP

• Input voltage :

-40°C (-40°F) to +85°C (185°F)

BPEST I Touch-To-Exit Button • Touch-sensitive illuminated button mounted on a stainless steel plate • 1 relay output, NO/NC, 8A / 250V • Adjustable sensitivity • Adjustable relay timer • Power requirements: 12Vac/dc

Manufacturing Access Control Since 1985

250 Vac @ 5A, 30 Vdc @ 5A or 50 Vdc @ 2A • Certifications : UL, CSA & SEMKO.

EST I Touch-Sensitive Electronics • Transforms any metallic surface into a Request-To-Exit device or switch • 1 relay output, NO/NC, 8A / 250V • Adjustable sensitivity • Adjustable relay timer • Power requirements: 12Vac/dc

c d v i . c a

23


Manufacturing Access Control since 1985

CDVI FRANCE 31, avenue du Général Leclerc 93500 PANTIN Tél. : +33 (0)1 48 91 01 02 Fax : +33 (0)1 48 91 21 21

CDVI FRANCE + EXPORT Phone: +33 (0)1 48 91 01 02 Fax: +33 (0)1 48 91 21 21

CDVI SUISSE Phone: +41 (0)21 882 18 41 Fax: +41 (0)21 882 18 42

CDVI ITALIA Phone: +39-0321-90573 Fax: +39-0321-908018

CDVI AMERICAS

Phone: +1 (450) 682-7945 Fax: +1 (450) 682-9590

CDVI CHINA CHINA Phone: +86 (0)10 87664065 Fax: +86 (0)10 87664165

CDVI MAROC Phone: +212 (0)5 22 48 09 40 Fax: +212 (0)5 22 48 34 69

CDVI BENELUX

CDVI IBÉRICA

CDVI SWEDEN

[CANADA - USA]

[BELGIUM - THE NETHERLANDS - LUXEMBOURG]

Phone: +32 (0) 56 73 93 00 Fax: +32 (0) 56 73 93 05

[SPAIN - PORTUGAL]

Phone: +34 (0)935 39 09 66 Fax: +34 (0)935 39 09 70

CDVI UK [UNITED KINGDOM - IRELAND]

Phone: +44 (0)1628 531300 Fax: +44 (0)1628 531003

[SWEDEN - DENMARK - NORWAY - FINLAND]

Phone: +46 (0)31 760 19 30 Fax: +46 (0)31 748 09 30

CDVI Group FRANCE (Headquarter/Siège social) Phone: +33 (0)1 48 91 01 02 Fax: +33 (0)1 48 91 21 21

cdvigroup.com All the instructions on this document (photos, drawings and specifications) are subject to change without notice. CDVICATA-E05 - Printed in Canada - October 2011


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.