Kentec- katalog opreme

Page 1

Leading in Fire Detection Control Systems Years For Over

25

Product Catalogue 2011 - 2012

By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford, Kent. DA1 1JQ


Leading in Fire Detection Control Systems For Over

25 Years

By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford, Kent. DA1 1JQ


Pages 48-61

Power Supplies

As part of our customer care Kentec offers first rate technical support facilities and a dedicated team of highly trained personnel provide direct telephone assistance; this is backed up by regular technical e-mail bulletins and on-site and offsite customer specific training. Kentec’s products are tested and approved to international standards such as EN54, EN12094, UL and FM. Kentec achieved ‘Investors in people’ accreditation in 2004. Our management systems are ISO 9001:2008 approved and our policy for environmental awareness was officially recognized in 2007 when we gained our ISO 14001 certification from BSI. In 2008 Kentec was proud to be awarded the Royal Warrant of Appointment by Her Majesty the Queen.

Miscellaneous

Custom

Pages 64-81

Extinguishant

Pages 84-88

At Kentec we believe that the quality of our products should be paramount; rigorous testing procedures are employed at every stage of the manufacturing process to ensure that all equipment is supplied to the highest standards. For this reason we are confident in offering an industry leading 3 years warranty on all product that we supply. We also understand that service is a key part of how a manufacturer’s quality is judged. To this end we have invested extensively not only in our manufacturing facilities but in our support team including technical support and training.

Conventional

Pages 92-101

Kentec offers the most comprehensive range of conventional, analogue addressable fire detection and extinguishant control panels available. Our custom build service is also highly regarded in the industry and utilises our expertise in control panel technology to design and build high quality product to exacting customer specifications. Marine products are now an important part of our product portfolio and we have now introduced the all new “Taktis” product range. Taktis will become one of the most comprehensive and dynamic products within the industry with its focus on added value and advanced technology.

Analogue Addressable

Pages 104-109

In keeping with our philosophy of in-house production we continue to invest heavily in state of the art manufacturing equipment for all areas of the business. This has allowed us to react quickly to customer requirements and market trends whilst maintaining our position at the forefront of Control panel design & manufacture. As an example of this, in early 2011, we opened our new World Class electronics manufacturing facility in Dartford. With this new facility we have been able to increase our capacity by over 30% resulting in even better customer support.

Pages 8-45

Established over 25 years ago, Kentec Electronics Ltd. has evolved into one of the world’s leading independent fire control panel manufacturers. Over the years the Kentec name has become synonymous with World class product, great service and excellent support. Based in the UK, Kentec is a truly global supplier, exporting control equipment to over 80 countries Worldwide, and in many different languages.


Our In-house facilities... Overview At the heart of our business lies the many in-house facilities that are at our disposal. From the initial design process, to sheet metal fabrication, to powder coating and printing through to panel construction, we have full control at every stage of our manufacturing process allowing us to offer industry leading delivery times and with quality that you can have confidence in. In March 2009 we opened a new facility in Dartford which now houses the metal fabrication, paint and print shops, and has more than tripled our overall size. This was further enhanced with the commissioning of our new “World Class� electronics manufacturing facility in early 2011.

Integral to our sheet metal fabrication department is a state of the art computer controlled Amada break press. A comprehensive range of tooling is available in this key area of our manufacturing process.

We also have a full range of bending, cropping, studding and welding plant equipment allowing us the capability and flexibility to produce single items or volume product.

Our versatile painting department features a semi automatic powder coating plant. Introduced in 2009 it continues to provide all our metal component finishing needs.

Page 4


Our printing department has recently been subject to a complete transformation moving from a traditional silk screen printing process to state of the art digital printing. In late 2010 we acquired an OCE Arizona digital UV large format printer. The introduction of the Arizona printer has revolutionised the department offering increased capacity, consistency and quality. We are now seeing over 95% of products printed using this new process and we will be moving forward to offer more attractive and visually pleasing products as we employ more of the features offered by the Arizona printer.

Electronic Sub assemblies are produced using our fully automated state of the art surface mount production line. We systematically utilise both Optical and electrical automatic test equipment to ensure each and every assembly is built to the same high standard and is fault free. All panels supplied by Kentec are manufactured and assembled in-house in the U.K. Before despatch all panels undergo a rigorous testing procedure, they are then given a final visual inspection.

To underpin our industry leading in-house manufacturing activities we employ teams of qualified and experienced mechanical, software and electronic hardware developers and technicians dedicated to both new product developments and existing ongoing product support. Page 5


Analogue Fire Detection Control Equipment Pages 8-45


D! IMPROVE Syncro AS Single or Two Loop Analogue Addressable Fire Control Panels Page 8-9

Syncro Guide PC Graphics Software Page 28-29

D! Syncro IMPROVE Multi Loop Analogue Addressable Fire C/P’s Page 10-13

Syncro Guide Repeater Providing Repeater Facility for any GUIDE System Page 30-31

! Syncro Response IMPROVED Analogue Addressable Fire Control Panel Repeaters Page 14-15

MIOU/LIOU Multi Input/ Output Unit (Standard and Light versions) Page 32-33

Syncro Focus Network LCD Repeater for Syncro System Page 16-17

Syncro I/O A range of I/O boards and enclosures Page 34-43

Syncro View Serial LCD Repeater for Syncro System Page 18-19

OpenConnect NEW! BMS Communications Interface Page 44-45

Syncro Ident Programmable LED Indication Panels Page 20-21 Syncro Matrix Intelligent Fire Alarm Mimic Display System Page 22-23 Syncro Net Syncro Network Interface Page 24-25

Syncro Comms Syncro Communications Module Page 26-27


Single or Two Loop Analogue Addressable Control Panel

PR O IM

AS

BS-EN54-2 BS-EN54-4 KM 73505

VE D !

Syncro

Product Overview Syncro AS is a versatile range of open protocol fire alarm control panels compatible with existing Syncro fire alarm panel technology. Available with one or two detection loops capable of hosting up to 126 devices (Apollo), 240 devices (Argus Vega) or 127 devices (Hochiki). Syncro AS uses leading edge microprocessor based electronics to provide a flexible control system with high reliability and integrity.

Features 16 zonal LED indicators 2 programmable sounder circuits 5 programmable inputs

Suitable for all small to medium sized fire detection systems, Syncro AS control panels can be expanded and networked to become part of much larger systems if the need arises, therefore providing a future proof solution for any installation. With its large graphical display and ergonomic button and indicator layout, the Syncro AS control panel is simple and straightforward to understand for installers, commissioning engineers and end users alike.

3 programmable relays (Also backward-compatible with Series 90 detectors)

3A power supply Large graphic display Real time clock Expandable from 1 to 2 loops* Certified to EN54-2/ EN54-4

R

Up to 512 additional programmable I/O via Syncro I/O modules * Powerful, network wide cause and effects *

Config. Features Comprehensive day/night mode facility Programmable one touch test mode Powerful and versatile cause & effect programming Cause & effect wizard including:

Cause & effect action

Disablement configuration

Test mode configuration

Sensitivity adjustment and Drift Compensation Can be networked with Syncro control panels * Compatible with Focus and View repeaters * Supports Apollo, Argus Vega and Hochiki protocols Same look and feel as Syncro range Stores 500 last events in event log Dial up modem connection available Compact, stylish enclosure Installer friendly, removable equipment chassis Different language and character set variants available Fully EN54-2 and EN54-4 compliant improved front loading Printer option * ** * These items not available on Syncro AS Lite panel ** Can be fitted to M3 size enclosure only

Page 8

Model No. #80161M2


DS47.06.2011

Panels Product Code

Protocol Zones Loops Printer Size (mm)

A80161M2 A80162M2 A80161M3 A80162M3 A80161M3P A80162M3P V80161M2 V80162M2 V80161M3 V80162M3 V80161M3P V80162M3P H80161M2 H80162M2 H80161M3 H80162M3 H80161M3P H80162M3P

Apollo Apollo Apollo Apollo Apollo Apollo Argus Vega Argus Vega Argus Vega Argus Vega Argus Vega Argus Vega Hochiki Hochiki Hochiki Hochiki Hochiki Hochiki

16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16

1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2

No No No No Yes Yes No No No No Yes Yes No No No No Yes Yes

385 x 310 x 90 * 385 x 310 x 90 * 385 x 520 x 110 385 x 520 x 110 385 x 520 x 110 385 x 520 x 110 385 x 310 x 90 * 385 x 310 x 90 * 385 x 520 x 110 385 x 520 x 110 385 x 520 x 110 385 x 520 x 110 385 x 310 x 90 * 385 x 310 x 90 * 385 x 520 x 110 385 x 520 x 110 385 x 520 x 110 385 x 520 x 110

Specification

* Flush versions are available to order (See price guide).

Lite Panels Product Code

Protocol Zones Loops Printer Size (mm)

LA80161M2 LV80161M2 LH80161M2

Apollo Argus Vega Hochiki

16 16 16

1 1 1

No No No

385 x 310 x 90 385 x 310 x 90 385 x 310 x 90

Technical

Options

Construction Finish Colour - lid & box Colour - controls plate & labels Display Mains voltage supply

-

Mains supply fuse Power supply DC rating Aux 24V supply Battery (24 hour standby) Fault contact rating Fire contact rating Alarm contact rating Sounder output rating Detection loop Detector protocols

-

Printer port Serial expansion port

-

PC port Network connection

-

Remote Silence input (SIL) Remote fault input (FLT) Remote reset input (RES) Remote alert input (INT) Remote evacuate input (CNT) Download lead Configuration PC graphics Modem

-

1.2mm mild sheet steel Epoxy powder coated BS 00 A 05 grey - fine texture RAL 7047 light grey - satin 8 lines of 40 characters graphic LCD

Product Description Code K555 K560 K547 K546 K545

110 or 230V AC 50 or 60 Hz. (specify when ordering, default is 230V) 1.6A 250V 24V 3 Amps Fused at 500 milliamps 9Ah 12V (2 per panel) (non-networked) K556P 30V DC 1 Amp 30V DC 1 Amp K768AS 30V DC 1 Amp Fused at 1 Amp each K18002 400 milliamp output Apollo (S90, XP95, Discovery), Argus Vega or Hochiki ESP B3472 Serial RS232 Serial RS485 (Compatible with all Syncro I/O modules) Serial RS232 RS485 - Up to 64 panels via fully fault tolerant optional network card Switched -ve Switched -ve Switched -ve Switched -ve Switched -ve Standard S187, X187LS economy Via Loop Explorer PC utility Via Guide systems Optional dial up modem for remote diagnostics (Can be fitted to M3 size enclosure only)

Fault tolerant Network interface card 16 channel input/output board 8 way relay extender board 6 way sounder extender board 4 way conventional detection zone board Modem module (PSTN) (M3 size enclosure only) Printer Module - New front loading feature (M3 size enclosure only) Retrofit Vision Window Door (M2 size enclosure only) Thermal Printer Paper Roll

The manufacturer reserves the right to amend specifications without prior notice

Page 9


Analogue Addressable Fire Control Panels

PR O IM

BS-EN54-2 BS-EN54-4 KM 73505

VE D !

Syncro

Product Overview Available with 2 or 4 detection circuits, each capable of hosting up to 126 devices (Apollo), 240 devices (Argus Vega) or 127 devices (Hochiki). Syncro uses the most advanced microprocessor technology to provide a control system of extremely high integrity. Syncro can be configured to suit all types of system, from the most simple, to the highly complex. Its fully integrated and secure network provides an intelligent interface for building control.

Features 2 or 4 loop versions as standard (for 6 - 8 loop versions see DS57 page 12-13) Larger enclosure available (fits 24A/H SLAs)

A large area graphic display ensures that information is presented in plain language with detailed extra help available by pressing a ‘help’ button. Syncro supports three of the most widely used communication protocols produced by leading fire detector manufacturers and employs daily calibration routines to ensure that the system is always at optimum performance.

Loopless panel option (repeater) (Also backward-compatible with Series 90 detectors)

0, 16, 48, or 96 zone indicators Option for Enable Control keyswitch Fully supports Apollo, Argus Vega & Hochiki protocols

R

Config. Features Comprehensive day/night mode facility Programmable one touch test mode

Network up to 64 panels/repeaters

Powerful and versatile cause & effect programming

4 programmable sounder circuits as standard

Cause & effect wizard including:

5.25 amp power supply to EN54 part 4 Large graphic display

Cause & effect action

Disablement configuration

Test mode configuration

In built help and alarm information screens Certified to EN54-2/ EN54-4 Real time clock Supports Apollo, Argus Vega and Hochiki loop powered sounders and beacons Supports Apollo Ancillary Base Sounder Supports Apollo Intelligent Beam Stylish enclosure design Soft-touch tactile buttons 2 programmable function buttons 3 programmable front panel mounted LED’s Improved Front loading Printer (optional) Up to 512 programmable inputs/outputs per panel via 2 wire RS485 serial link (optional) Simple Windows® graphical configuration utility

Page 10

Model No. EN#6396403P


DS16.14.2011

Panels 2 Loop Panels

EN#6300203 EN#6316203 EN#6348203 EN#6396203

2 2 2 2

0 16 48 96

500 x 355 x 117 500 x 355 x 117 500 x 355 x 117 500 x 355 x 117

4 Loop Panels Larger Enclosure 4 Loop Panels

Product Code Loops Zones Size (mm)

EN#6300403 EN#6316403 EN#6348403 EN#6396403

4 4 4 4

0 16 48 96

500 x 355 x 117 500 x 355 x 117 500 x 355 x 117 500 x 355 x 117

EN#6300415 EN#6316415 EN#6348415 EN#6396415

4 4 4 4

0 16 48 96

500 x 460 x 190 500 x 460 x 190 500 x 460 x 190 500 x 460 x 190

Specification

‘#’ - replace with ‘A’ for Apollo protocol, ‘V’ for Argus Vega protocol or ‘H’ for Hochiki protocol. Flush versions are available to order (See price guide). For fitted printer add ‘P’ after stock code.

Options Product Code Description Loop extension card (loops 3 & 4) K552# Fault tolerant Network interface card K555 Thermal printer kit (for retrofitting to non-printer models) K768SYN 16 channel input/output board K560 8 way relay extender board K547 6 way sounder extender board K546 4 way conventional detection zone board K545 Modem module (PSTN) K556P Thermal Printer Paper Roll B3472 ‘#’ - replace with ‘A’ for Apollo protocol, 361mm ‘V’ for Argus Vega protocol or ‘H’ for Hochiki protocol.

506mm

Technical Construction Finish Colour - lid & box Colour - controls plate & labels Display Detection circuits (Loops) Zone LED’s 4 sounder circuits Fire contact Alarm contact Fault contact Programmable relay 1 Programmable relay 2 Fire routing output Fault routing output Extinguisher output Fault input Reset input Intermittent input Continuous input Silence input Programmable input 1 Programmable input 2 Programmable input 3 Auxiliary 24V DC output System fuse Mains fuse Operating Temperature Operating humidity Mains voltage supply

-

Battery (24 hour standby) Day/night modes Input delays Output delays 2 programmable function buttons 3 programmable indicators Network (option) Printer (option) Download lead

-

-

-

1.2mm mild sheet steel Epoxy powder coated BS 00 A 05 grey - fine texture 130mm Model No. EN#6396414 RAL 7047 light grey - satin Bezel extends 15mm 8 lines of 40 characters graphic LCD in each direction 2 or 4 (400mA each) 0, 16, 48, or 96 (up to 500 software zones) Each fused at 1 Amp (total load 2 Amp) Volt free 1 Amp 30V DC Volt free 1 Amp 30V DC Volt free 1 Amp 30V DC Flush Syncro Control Panel Volt free 1 Amp 30V DC Volt free 1 Amp 30V DC Monitored-voltage reversing, fused at 500mA Monitored-voltage reversing, fused at 500mA Monitored-voltage reversing, fused at 1A Volt free contact input signals fault Volt free contact input resets panel Volt free contact input pulses sounder outputs Control Volt free contact input for continuous sounders Panel Volt free contact input silences sounders Volt free contact for any action required Volt free contact for any action required Volt free contact for any action required Fused at 500mA Wall 5 Amp self-resetting polyfuse 20mm 3 Amp Flush mount cross section -5 to +50 deg. C Note: There is one size for all To 95% (non-condensing) standard flush Syncro control 110 or 230V AC 50 or 60 Hz. panels. For the hole size we (specify when ordering, default is 230V) recommend that you allow 12Ah 12V (2 per panel) (non-networked) 5mm clearance all round. 2 with variable device sensitivity Individual for each device selectable up to 2 minutes Individual 2-stage to 10 minutes per stage Programmable to carry out any cause & effect, disablement or test action Red/yellow/green to indicate any action Up to 64 panels on 2 wires (K555 Network Card required) New front loading feature S187 (standard) or X187LS (economy) The manufacturer reserves the right to amend specifications without prior notice

Page 11


IM

PR O

VE D !

Syncro Analogue Addressable Fire Control Panels 6 or 8 Loops

Product Overview Available with 6 or 8 detection circuits, each capable of hosting up to 126 devices (Apollo), 240 devices (Argus Vega) or 127 devices (Hochiki). Syncro uses the most advanced microprocessor technology to provide a control system of extremely high integrity. Syncro can be configured to suit all types of system, from the most simple, to the highly complex. Its fully integrated and secure network provides comprehensive scalability. A large area graphic display ensures that information is presented in plain language with detailed extra help available by pressing a ‘help’ button.

Features 6 or 8 loop versions as standard 96 zone indicators Fully supports Apollo, Argus Vega & Hochiki protocols Network up to 32 6 or 8 loop panels (Also backward-compatible with Series 90 detectors)

8 programmable sounder circuits as standard 2 x 5.25 amp PSU’s to EN54 part 4 Large graphic display In built help and alarm information screens Certified to EN54-2/ EN54-4

R

Syncro supports three of the most widely used communication protocols produced by leading fire detector manufacturers and employs daily calibration routines to ensure that the system is always at optimum performance.

Config. Features Comprehensive day/night mode facility Programmable one touch test mode Powerful and versatile cause & effect programming Cause & effect wizard including:

Cause & effect action

Disablement configuration

Test mode configuration

Real time clock Supports Apollo, Argus Vega and Hochiki loop powered sounders and beacons Stylish enclosure design Soft-touch tactile buttons 2 programmable function buttons 3 programmable front panel mounted LED’s Improved Front loading Printer (optional) Up to 1024 programmable inputs/outputs per panel via 2 wire RS485 serial link (optional) Simple Windows® graphical configuration utility Wide choice of languages available

Model No. EN#63966S4P

Page 12


DS57.03.2011

Panels Product Code

Loops Enable Zones Size (mm) Control

EN#63966S4 ENS#63966S4 EN#63968S4 ENS#63968S4

6 6 8 8

No Yes No Yes

96 96 96 96

500W x 650H x 137D 500W x 650H x 137D 500W x 650H x 137D 500W x 650H x 137D

Specification

‘#’ - replace with ‘A’ for Apollo protocol, ‘V’ for Argus Vega protocol or ‘H’ for Hochiki protocol. For fitted printer add ‘P’ after stock code.

Technical

Options

Construction Finish Colour - lid & box Colour - controls plate & labels Display Detection circuits (Loops) Zone LED’s 8 sounder circuits

-

2 x Fire contact 2 x Alarm contact 2 x Fault contact 2 x Programmable relay 1 2 x Programmable relay 2 2 x Fire routing output

-

2 x Fault routing output

-

2 x Extinguisher output

-

2 x Fault input 2 x Reset input 2 x Intermittent input 2 x Continuous input 2 x Silence input 2 x Programmable input 1 2 x Programmable input 2 2 x Programmable input 3 2 x Auxiliary 24V DC output 2 x System fuse 2 x Mains fuse Operating Temperature Operating humidity Mains voltage supply Battery (24 hour standby) Day/night modes Input delays Output delays 2 programmable function buttons 3 programmable indicators Network Printer (option) Download lead

-

1.2mm mild sheet steel Product Description Epoxy powder coated Code BS 00 A 05 grey - fine texture Loop extension card (loops 7 & 8) K552# RAL 7047 light grey - satin K768SYN Thermal printer kit (for retrofitting 8 lines of 40 characters graphic LCD to non-printer models) 6 or 8 (400mA each) 16 channel input/output board K560 96 (up to 500 software zones) Each fused at 1 Amp 8 way relay extender board K547 (total load 2 Amp per bank of 4 circuits) 6 way sounder extender board K546 Volt free 1 Amp 30V DC 4 way conventional detection zone K545 Volt free 1 Amp 30V DC board Volt free 1 Amp 30V DC Modem module (PSTN) K556P Volt free 1 Amp 30V DC Volt free 1 Amp 30V DC Thermal Paper Printer Roll B3472 Monitored-voltage reversing, ‘#’ - replace with ‘A’ for Apollo protocol, fused at 500mA ‘V’ for Argus Vega protocol or ‘H’ for Hochiki protocol. Monitored-voltage reversing, fused at 500mA Monitored-voltage reversing, fused at 1A Volt free contact input signals fault Volt free contact input resets panel Volt free contact input pulses sounder outputs Volt free contact input for continuous sounders Volt free contact input silences sounders Volt free contact for any action required Volt free contact for any action required Volt free contact for any action required Fused at 500mA 5 Amp self-resetting polyfuse 20mm 3 Amp -5 to +50 deg. C To 95% (non-condensing) 110 or 230V AC 50 or 60 Hz. (specify when ordering, default is 230V) 12Ah 12V (4 per panel) 2 with variable device sensitivity Individual for each device selectable up to 2 minutes Individual 2-stage to 10 minutes per stage Programmable to carry out any cause & effect, disablement or test action Red/yellow/green to indicate any action Up to 32 6 or 8 loop panels on 2 wires New front loading feature S187 (standard) or X187LS (economy) The manufacturer reserves the right to amend specifications without prior notice

Page 13


VE D !

IM

Response

PR O

Syncro Analogue Addressable Fire Control Panel Repeaters

Product Overview Syncro Response is a full function repeater panel used to compliment the Syncro control panel range. Syncro Response uses the most advanced microprocessor technology to provide a control system of extremely high integrity. Syncro Response can be configured to suit all types of system, to provide selectable event reporting and controls from each panel on the network. A large area graphic display ensures that information is presented in plain language with detailed extra help available by pressing a “help” button.

Features 0, 16, 48, or 96 zone indicators

Syncro networks support three of the most widely used communication protocols used by leading fire detection manufacturers.

Network up to 64 panels/repeaters 5.25 amp power supply to EN54 part 4 Large graphic display

Config. Features

In built help and alarm information screens

Programmable one touch test mode

Complies with EN54-2

Powerful and versatile cause & effect programming

Real time clock

Cause & effect wizard including:

Stylish enclosure design

Cause & effect action

Disablement configuration

Test mode configuration

Soft-touch tactile buttons 2 programmable function buttons 3 programmable front panel mounted LED’s Improved Front loading Printer (optional) Up to 512 programmable inputs/outputs per panel via 2 wire RS485 serial link (optional) Simple Windows graphical configuration utility

Model No. #6196003

Page 14


DS17.09.2011

Specification

Panels Product Code Loops Zones Size (mm) K6100003 K6116003 K6148003 K6196003

0 0 0 0

0 500 x 355 x 117 16 500 x 355 x 117 48 500 x 355 x 117 96 500 x 355 x 117 Flush versions are available to order. For fitted printer add ‘P’ after stock code

Options Product Code Description K768SYN K560 K547 K546 K545 K556P B3472

Thermal printer kit (for retrofitting to non printer models) 16 channel input/output board 8 way relay extender board 6 way sounder extender board 4 way conventional detection zone board Modem module (PSTN) Thermal Printer Paper Roll

Technical Construction Finish Colour - lid & box Colour - controls plate & labels Display Zones Alarm contact Fault contact Programmable relay 1 Programmable relay 2 Auxiliary 24V DC output System fuse Mains fuse Operating Temperature Operating humidity Mains voltage supply Battery (24 hour standby) Day/night modes Input delays Output delays 2 programmable function buttons 3 programmable indicators Printer (option) Download lead

-

1.2mm mild sheet steel Epoxy powder coated BS 00 A 05 grey - fine texture RAL 7047 light grey - satin 8 lines of 40 characters graphic LCD 0, 16, 48, or 96 Volt free 1 Amp 30V DC Volt free 1 Amp 30V DC Volt free 1 Amp 30V DC Volt free 1 Amp 30V DC Fused at 500mA 5 Amp self-resetting polyfuse 20mm 3 Amp -5 to +50 deg. C To 95% (non-condensing) 110 or 230V AC 50 or 60 Hz. (specify when ordering, default is 230V) 12V 12Ah (2 per panel) 2 with variable device sensitivity Individual for each input selectable up to 2 minutes Individual 2-stage to 10 minutes per stage Programmable to carry out any cause & effect, disablement or test action Red/yellow/green to indicate any action New front loading feature S187 (standard) or X187LS (economy)

Note: Syncro Response is supplied complete with K555 network interface card fitted. Note: If this panel is to be fitted to an existing system the main panel must be also be fitted with and K555 network interface card to enable communications. 6 & 8 loop panels have a network card fitted as standard.

The manufacturer reserves the right to amend specifications without prior notice

Page 15


Syncro

Syncro

Focus+

Focus

Network LCD Repeaters

Features

Product Overview

Large graphic display

This simple and attractive repeater panel can be connected to any point on a Syncro network to provide additional display points as needed.

Simple connection to Syncro network 24V DC powered (230V AC available)

Using the same large format graphics display as the main control panel ensures that a clear and concise indication is given at all times.

Small attractive enclosure Configurable to display all or any events Simple to install Volt free Alarm, Fire and Fault contacts Up to 63 repeaters can be connected to a panel Focus+ with full controls has the following extra buttons:

Silence Alarm

Resound Alarm

Ideal for additional building entrances, security desks or nurses stations this unit provides an economical alternative to a full function repeater panel. (Syncro Response) The repeater also acts as a network booster and can be used to extend cable runs beyond the specified lengths as required.

Reset A

1.2 KILOMETRES MAX.

B

NETWORK

NETWORK

NETWORK

NETWORK

NETWORK

NETWORK

PANEL 1 0 LOOP

PANEL 2 2 LOOP

PANEL 3 4 LOOP

PANEL 4 4 LOOP

FOCUS PANEL 5

FOCUS+ PANEL 6

REPEATER

REMOTE MONITORING & CONTROL

ALLOWS DISTANCES GREATER THAN 1.2 KILOMETRES

PC GRAPHICS SYSTEM

NETWORK REPEATER PANEL 9

SIGNAL BOOSTER PANEL 7

Note: Signal booster is a Focus or Focus+ repeater used as a booster.

REPEATER PANEL 8

Example of a Syncro high integrity network

Focus Model No. K69000M1

Page 16

Focus+ Model No. K691000M1


DS24.10.2011

Focus Units Product Code K68000M1 K69000M1 K68000F1 K69000F1

PSU

Weight

Build

750mA 750mA

2.5kg 4.0kg 2.5kg 4.0kg

Surface Surface Semi Flush Semi Flush

PSU

Weight

Build

750mA 750mA

3.5kg 4.0kg 3.5kg 4.0kg

Surface Surface Semi Flush Semi Flush

Size (mm) 330 x 255 x 90 330 x 255 x 90 330 x 255 x 90 330 x 255 x 90

Specification

Focus+ Units Product Code K681000M1 K691000M1 K681000F1 K691000F1

Size (mm) 330 x 255 x 90 330 x 255 x 90 330 x 255 x 90 330 x 255 x 90

Syncro Focus/Focus+ PCB 24V

NET. OUT

NET. IN

PSU FLT. NC C

FAULT

FIRE

From previous panel on network

24V battery backed power (2.3Ah for 24H standby)

ALARM

NO NC C NC NO C NC NO C

To normally closed contact on local PSU

To next panel on network

Technical Construction Finish Colour - lid & box Colour - controls plate & labels Display Input voltage (24V DC model) Input voltage (230V AC model) Current consumption Alarm current Alarm contact rating Fire contact rating Fault contact rating Display Cable entry Indicators Battery Size (24 hr. standby on 230V AC model) Communications Cable length

Network cable type Operating temperature

-

1.2mm mild sheet steel Epoxy powder coated BS 00 A 05 grey - fine texture Ral 7047 light grey - satin 8 lines of 40 characters graphic LCD

21V DC - 30V DC 230V AC +10%/-15% 80mA at 24V DC (in fault condition) 100mA at 24V DC 30V DC 1 Amp max. 30V DC 1 Amp max. 30V DC 1 Amp max. 240 x 64 pixel graphic LCD 20mm knockouts 5mm high brightness LED 2.3Ah 12V (2 per panel)

- Syncro system network protocol only - 1200 metres to adjacent nodes

(subject to cable type) (see technical manual) - Belden 9271, Belden 9860, FP200 Gold - -5째C to +40째C

NOTE: An K555 network card is required in the Syncro/Syncro AS panel in order to communicate with these products. 6 - 8 loop panels have a network card fitted as standard. The manufacturer reserves the right to amend specifications without prior notice

Page 17


Syncro

View

Local LCD Control Panel Repeater

Product Overview Designed and manufactured to the highest standards in a quality controlled environment the Syncro VIEW fire alarm annunciator provides a simple and convenient method of extending the controls and indications of the Syncro fire alarm control panel to other locations. The large, graphic liquid crystal display and high brightness LED indicators duplicate the indications on the Syncro fire alarm control panel at up to 15 additional locations via a simple, two-wire serial data connection.

Features Up to 15 annunciators can be connected to each Syncro, Syncro Response or Syncro AS fire control panel. Large liquid crystal display (240 x 64 pixels) High brightness LED indications Internal sounder Replicates all Syncro panel controls Simple, two-wire serial connection

The Syncro VIEW is available in either a 24V DC powered option (which can be powered via an additional 2 cores from the Syncro control panel/local 24V DC supply) or a 230V powered option with local battery back up. Syncro VIEW is housed in a small enclosure which is styled similarly to the Syncro control panel and is ideal for installations where a large control panel would be detrimental to dĂŠcor such as entrance halls. Up to 15 Syncro VIEW annunciators can be connected to each control panel on the Syncro network making VIEW ideal where multiple points of indication and/or control are required such as nurses stations or shop units.

Small, Syncro style enclosure Removable electronics for easy installation 24V DC or 230V AC power options Low power consumption Multi language options Connection monitored by Syncro fire control panel

Model No. K67750M1

Page 18


DS43.04.2011

Equipment Product Code Description K67000M1 K67750M1 K67001M1 K67751M1

Specification

PSU Size (mm)

Syncro View repeater panel Syncro View repeater panel Syncro View repeater panel c/w enable keyswitch Syncro View repeater panel c/w enable keyswitch

750mA 750mA

330 x 255 x 90 330 x 255 x 90 330 x 255 x 90 330 x 255 x 90

Semi-flush versions are available to order

Syncro Control Panel

Syncro View #1 Comms Aux 24V

Comms In

Comms Out

24V In

24V Out

Syncro View #15

Comms In

Comms Out

24V In

24V Out

Technical Construction Finish Colour - lid & box Colour - controls plate & labels Display Cable entry Mains supply (Mains models only) 24V supply (24V DC models only) Mains supply fuse Power supply rating Maximum ripple current Battery type (Yuasa NP) Battery charge voltage Battery charge current Battery fuse Maximum current draw from batteries Quiescent current of panel in mains fail Serial data connection Maximum terminal capacity

-

1.2mm mild sheet steel Epoxy powder coated BS 00 A 05 grey - fine texture Ral 7047 light grey - satin 8 lines of 40 characters graphic LCD

5 x 20mm knockouts in top of box and 5 in rear 230V AC +10% - 15% (20 Watts maximum) 21 to 30V DC 2 Amp, 20mm 28V 750mA total (including battery charging) 200 millivolts Two 12 Volt 1.9Ah sealed lead acid in series 27.6VDC nominal 200mA maximum 200mA, 20mm, glass 95mA 0.03 Amps 2 core RS485 (Up to 1200 metres total cable length) 2.5mm²

The manufacturer reserves the right to amend specifications without prior notice

Page 19


Syncro Ident

Programmable, LED Indication Panels

Features 8 and 24 LED versions available as standard Large versions available to special order Up to 16 x 24 way Syncro Ident can be connected to each fire panel Programmable flashing or steady states Red, yellow or green indications/ options Common Fire, Fault and Disabled indication Customisable label identification tags

Product Overview Syncro Ident panels provide a compact and attractive display for up to 24 indications from a Syncro or Syncro AS fire control panel. As with all inputs and outputs on the Syncro system, each indicator is fully programmable to indicate a variety of events as well as being fully programmable via cause and effects to operate in response to logically connected inputs. Each indication defaults to a zonal fire indicator but may be configured via the Loop Explorer configuration utility to operate upon any event type or combination of inputs. Requiring only a low current 24V power supply and a 2 core data connection to the fire panel, Syncro Ident panels can be installed quickly and easily to provide supplementary information on the status of the fire alarm system with the minimum of cost and effort. The compact, slimline enclosure is unobtrusive and is ideal for mounting in locations where a larger control and indication unit would be unsuitable. Each indication has a dedicated field for customized text to provide a concise description of the indication. Multiple Syncro Ident panels can be connected to the Syncro serial bus to provide a diverse range of indications at multiple locations.

Buzzer with silence control and re-sound Lamp test control Low power 24V DC supply Connects to 2 wire Syncro RS485 data bus Multiple language options

Model No. K6524L2

Page 20


DS60.02.2011

Panels Product Code

No. of LEDs

K6508L2 K6524L2

8 24

Specification

Size (mm) 385 x 310 x 60 385 x 310 x 60

Versions with more LED indications available to special order

Technical Construction Finish Colour - lid & box Colour - controls plate & labels LED colours Supply Voltage Data Connection

1.2mm mild sheet steel Epoxy powder coated

-

BS 00 A 05 grey - fine texture RAL 7047 light grey - satin

- Red, yellow or green - 18 to 30V DC - RS485 Syncro comms bus (Max 1200 metres)

Examples of Syncro Ident panel used to provide supplementary indications from the fire control panel Syncro AS Fire Control Panel

Fire

More Events

Power On

General Disablement

Pre-Alarm

General Fault

On Test

Power Fault

Buzzer Silenced

System Fault

Delay Active

Re-Sound Alarm

1

15:05 Tuesday 10 October 2006 KENTEC ELECTRONICS LIMITED

4

Fire in Zone

Exit

Enter

More Fires

More Events

?

2

3 1

Sounder

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

Fault/Disabled

Silence Alarm (Acknowledge)

Silence Buzzer

Lamp Test

Reset

Evacuate

Function

Plant Status

Zonal Fire Indicators

RS485 2 Core Data Cable Enable Control

2 Core Power Cable

Fire Protection Indicator

Lamp Test

Fire

Buzzer Silence

Power On

Power On

Fault

Fault

Disablement

Disablement

Fire Detection Indicator

Fire Detection Indicator

Model:

Model:

Lamp Test

Buzzer Silence

Lamp Test

Buzzer Silence

LT

Model:

Fire

1 2

3 4 5

6

11

I/O CHANNEL

7

8 9 10

Pre-Alarm Fire Routing On

15

Enable Control

I/O

24V 0V 0V 0V

Alarm Silence

0V

Reset

Fault

More Events

COMMS IN

4 Exit

? 3

Power Fault

More Events

2

System Fault Sounder Fault/Disabled

Enter

Fire Routing Fault/Disabled

Fire Silence Alarm (Acknowledge)

Silence Buzzer

Lamp Test

Reset

Function One

Power On

Function Two

Fault

Disablement 0V 24V 0V

IN

More Fires

Delay Active

General Disablement

Re-Sound Alarm

Disablement

General Fault

1

Buzzer Silenced

COMMS OUT OUT

Power On

Buzzer Silence

KENTEC ELECTRONICS LIMITED

On Test

16

Lamp Test

15:05 Tuesday 22 August 2006

Power On

13 14

Fire

Fire

12

Fire Alarm Repeater Fire Detection Indicator

Fire Alarm Mimic Display

Model:

Syncro Matrix

Syncro I/O

Syncro View

Disabled Refuge Alarms

Other RS485 compatible devices

The manufacturer reserves the right to amend specifications without prior notice

Page 21


Syncro

Matrix

Product Overview

Intelligent Fire Alarm Mimic Display System

The Syncro Matrix system uses flexible, fibre optic light guides to illuminate areas on a floor plan, laid over a high resolution grid. This unique system dispenses completely with wiring and enables indicators to be moved, removed or added on site without the need for any wiring.

Features Up to 504 LED’s can be controlled from any Syncro or Syncro AS panel Full colour printing Available in a range of standard enclosures to suit any applications Bespoke sized units can be made upon request Choice of Red, Green or Yellow LED’s Available with or without controls

All indicators can be configured to operate upon any event type and at point, zone or group level via Kentec’s powerful and intuitive Loop Explorer configuration programme. Syncro Matrix can be supplied with or without LEDs and controls. Optional LEDs indicate Power on, Fire, Fault and Disablement and optional controls are for Alarm silence, Buzzer silence, Lamp test and Reset. Housed in attractive, slimline enclosures to match Syncro and Syncro AS fire alarm panels and with high quality, full colour or monochrome floor plans, Syncro Matrix provides a clear, geographical indication of fire alarm activation enabling speedy identification of the source of an alarm.

Same look and feel as Syncro range Syncro Matrix can easily be upgraded on site with minimal cost and effort EN54-4 approved PSU (optional) Configured via standard Loop Explorer Software

View showing mimic mounted on inner door

View showing LED grid

View showing internal layout

PSU optional

Page 22

M3 size Syncro Matrix


DS52.03.2011

Specification

Panels No. LED’s

Standby Full Alarm Batteries for Batteries for Current Current 24 hours 48 hours

24 56 88

0.026 0.052 0.078

0.09 0.18 0.36

0.88Ah 1.75Ah 2.8Ah

1.76Ah 3.5Ah 5.2Ah

Enclosure Size Options Max. number of Max. number of Max. number of Max. number of LED’s = 24 LED’s = 56 LED’s = 88 LED’s = 56 Will house 1 x 8 Red LED Will house 1 x 8 Red LED Will house 1 x 8 Red LED Will house 1 x 8 Red LED driver PCB and driver PCB and driver PCB and driver PCB and 1 x 16 LED 3 x 16 LED 5 x 16 LED 3 x 16 LED extension PCB’s extension PCB’s extension PCB’s extension PCB’s (Red, Green or Yellow) (Red, Green or Yellow) (Red, Green or Yellow) (Red, Green or Yellow)

Max. number of LED’s = 504 Will house 1 x 8 LED driver PCB (Red) and up to 31 x 16 LED extension PCB’s (Red, Green or Yellow)

Bespoke Size S4

? ?

M3 S3

M2 303

185

385mm x 310mm 90mm Deep

400

515 400

400 303 225

500mm x 355mm 117mm Deep

385mm x 520mm 110mm Deep

500mm x 650mm 137mm Deep

Colour/Finish & Size to suit your requirements

Technical Construction Finish Colour - lid & box Colour - controls plate & labels Mimic Number of indicators (standard models) Mains supply (230V Versions only) Mains supply fuse (230 V Versions only) Power supply rating (230 V Versions only) Max. ripple current (230 V Versions only) Battery type (Yuasa NP) (230 V Versions only) Battery charge voltage (230 V Versions only) Battery charge current (230 V Versions only) Max. current draw from batteries (230 V Versions only) Quiescent current Supply voltage (24V versions) Supply current Terminal capacity Enable keyswitch (if fitted) Cabinet locks Communications interface Maximum distance from control panel IP rating Operating temperature

-

1.2mm mild steel Epoxy powder coated BS 00 A 05 grey - fine texture RAL 7047 light grey - satin

3mm Clear Anti-Glare Acrylic M2 size - up to 24, M3 and S3 size - up to 56, S4 size - up to 88 230V AC +10% - 15% (100 Watts max.) T2A L250V Replace only with similar type 5.25 Amps total including battery charge 28V +/ 2V 200 millivolts Two 12 Volt sealed lead acid (7Ah maximum)

- 27.6VDC nominal (temperature compensated) - 1.5A maximum - 3 Amps. With mains power source disconnected -

See above 21 to 30V DC See above 0.5mm2 to 2.5mm2 solid or stranded wire Standard 901 key M2/M3 - standard 801 key, S3/S4 - standard KT3001 key RS485 – Syncro/Syncro AS serial I/O bus protocol 1.2Km using RS485 data cable IP30 -5°C to +50°C The manufacturer reserves the right to amend specifications without prior notice

Page 23


Syncro Net

Syncro Networking

Product Overview The flexibility of the Syncro system can be further enhanced by connecting control panels and repeaters together using a high integrity network. A simple 2-wire connection between each panel allows events to be transmitted to other parts of the system to provide indication or control on a system wide basis. Using the Loop Explorer configuration programme, up to 64 nodes can be programmed to respond in a variety of ways to any system events as required.

Features Up to 64 nodes High integrity protocol Fully secure against short or open circuit faults Simple 2-wire loop connection

This flexibility extends the comprehensive cause and effect programming capability of Syncro control panels to the entire network allowing actions, test modes or disablements to be started from any point. The fault tolerance of the network is such that any single open or short circuit fault will not result in any loss of information. Multiple faults are isolated and the network breaks into smaller networks which continue to work autonomously.

Supports open ended networks for retrofit applications Repeaters share network connection Network wide test and disablement functions Network wide cause and effect logic Flexible configuration options Panels configurable to act on network events or not as required Apollo & Hochiki panels supported on single network

Part No. K555

Page 24


DS23.07.2009

Flexible network configuration options using simple to follow PC configuration programme

Specification

Two core loop wiring ensures network integrity by providing full isolation of faulty wiring segments.

2 Core

Control Panel

Control Panel

2 Core

(Not fitted on open ended networks)

2 Core

Control Panel

Technical Product code Protocol Connection Current Consumption Integrity Indicators Cable length Cable type Compatible panels

K555 RS485 Two wire loop 40mA Full isolation of faulty nodes or wiring segments Data In and Data Out communications status 1200 metres to adjacent nodes (subject to cable type) (see technical manual) - Belden 9271, Belden 9860, FP200 Gold - Syncro/Syncro AS (required for networking) Syncro Response/Syncro 6 & 8 loop, Syncro Focus (supplied with panel) -

The manufacturer reserves the right to amend specifications without prior notice

Page 25


Syncro

Comms

Communications Module (modem)

Product Overview The K556 communications module enables service companies to interrogate control panels remotely via a telephone link. The communications module is simple to install and requires a PSTN telephone line. The module mounts on existing pillars in the control panel and is supplied with all wiring and connections to enable speedy installation and commissioning.

Features View devices near calibration limits Plan maintenance visits Retrieve event log Dial in and observe reported faults Assist commissioning from remote location Offer value added service to customers Check software version to see if updates are available Retrieve configuration Avoid unnecessary call outs Simple to install Dongle protected access, for customers security

Page 26

Once connected to the control panel via the Loop Explorer software, users can upload configuration data and event logs or take control of the system via the virtual panel interface. This allows the panel controls to be operated as if the user was standing at the panel. The Loop Explorer configuration programme (version 3.0 or higher) is used to dial into control panels but the dial up facility will not be available unless the PC calling the control panel is fitted with a registered dongle (part number B2158 for parallel port or B2158USB for USB version).


DS31.07.2011

PC running Loop Explorer Programme & fitted with Dongle

Public Telephone Network

Specification

Syncro Control Panel fitted with Communications Module

Note: The Communications Module is compatible with Loop Explorer Software version 3 or above and Syncro Control Panel Firmware version 3 or above.

Technical Module part number Size Supply voltage Current consumption Connection Dongle part number

-

K556P (PSTN) 190mm(H) x 62mm(W) x 40mm(D) 21V to 30V DC 50 milliamps PSTN B2158 (parallel port) B2158USB (USB serial port)

Note: One dongle required per user, to enable the ‘dial in’ facility within the Loop Explorer program

The manufacturer reserves the right to amend specifications without prior notice

Page 27


Syncro

GUIDE

Graphical User Interface for fire Detection Equipment

Product Overview Syncro fire control panels can send data to, and be controlled by, the Guide system providing a single point of co-ordination for all alarms. The powerful 32 bit programme features a standard Windows look and feel and runs under WindowsÂŽ 2000 , XP, Vista or Windows 7 Professional. The system is highly configurable in terms of the style of presentation so that the end user can be presented with maps, text, photographs, audio or a combination of all as required. User profiles allow the system manager to control the facilities available to each individual system user.

Virtual Panel - allows direct control

A comprehensive history logging and reporting system allows analysis of events and trends to be identified to reduce unwanted alarms. Easy to programme and simple to use, Guide provides a cost effective solution for fire alarm management at many levels.

Powerful Event log filtering

Features Choice of text, graphic, event list display when an event occurs Versatile event analysis Total history archive Easy to programme Secure system Cost effective compared to other systems Simple to use Unlimited map linking & zoom facility Support for 100’s of graphics Display and control for multiple panels Event history explore and export facility to text or HTML documents

Page 28


DS18.10.2009

Range Product Code Description G1001 G1004 G1008 G1016 G1032 G1064

GUIDE software - Single panel package GUIDE software - 4 panel package GUIDE software - 8 panel package GUIDE software - 16 panel package GUIDE software - 32 panel package GUIDE software - 64 panel package

Specification

Note: Guide For use with Syncro Panels. Syncro 6 & 8 loop panels are considered 2 panels in the packages above.

Technical Recommended Minimum Notes Intel Pentium 1Ghz Processor Operating system Windows速 XP/Vista , 7 Professional 1Gb minimum Memory 10GB minimum Hard disk 1024 x 768 16M colours Graphics Sound card Loudspeaker Monitor Pointing device

Any PC sound card Any PC speakers Any that supports above graphics driver Mouse essential

Printer Parallel port Serial ports

Optional Optional One RS232 per network

CDROM drive

Any

Backup drive

CD Writer

The faster the better Will operate under Windows速 2000 The larger the better. The driver must allow this mode with large fonts. Separate Graphics card with 256MB graphics memory recommended More convenient if built into PC. 17 inch minimum recommended, the larger the better. (1024 x 768) Third button and wheels are supported. Touch screen option supported Any type. Required if parallel printer to be used. Isolated converter supplied for connection to fire alarm system. Required for installation of software and updates. To back up history.

Note: Guide will be operating 24 hours a day for many years. It may be desirable to include on site PC maintenance as part of the package. Note: The Syncro panel to which the Guide system is connected must not have a printer fitted.

Fire Control Panel

Fire Control Panel

Dongle fitted

Guide System

RS485

Fire Control Panel The manufacturer reserves the right to amend specifications without prior notice

Page 29


Syncro

GUIDE Repeater

Providing Repeater Facility for any GUIDE System

Product Overview Syncro GUIDE Repeater is an additional facility for the Syncro GUIDE fire alarm management system. GUIDE Repeater allows monitoring and limited control of the Syncro fire control system to be repeated on dedicated computers connected to the building Local Area Network. GUIDE Repeater is highly configurable allowing replication of the main GUIDE system or alternative information to be given at the repeater

Features Up to 16 GUIDE Repeaters may be connected to a single GUIDE system All monitoring options on GUIDE are supported on the GUIDE repeater. Device an zone disablements may also be performed from the Guide repeater. Choice of text, graphics, combined display when an event occurs. Easy to use Allows graphical information of fire events to be shown at alternative locations Unlimited map linking and zoom facility Display and control for up to 64-networked Syncro panels

Guide Repeater user interface

Page 30


DS45.02.2009

Range Product Code Description GR2001 GR2004 GR2016

Specification

GUIDE Repeater - single repeater package GUIDE Repeater - 4 repeater package GUIDE Repeater - 16 repeater package

Technical Recommended Minimum Notes Intel Pentium 1Ghz Processor Operating system Windows速 XP/Vista / 7 Professional 256MB minimum Memory 10GB minimum Hard disk 1024 x 768 16M colours Graphics Sound card Loudspeaker Monitor Pointing device

Any PC sound card Any PC speakers Any that supports above graphics driver Mouse essential

Printer Parallel port Network CDROM drive

Optional Optional One network port Any

Backup drive

CD Writer

The faster the better Will operate under Windows速 2000 The larger the better. The driver must allow this mode with large fonts. Separate Graphics card with 256MB graphics memory recommended More convenient if built into PC. 17 inch minimum recommended, the larger the better. (1024 x 768) Third button and wheels are supported. Touch screen option supported Any type. Required if parallel printer to be used. Required for installation of software and updates. To back up history.

LAN Dongle fitted

RS485

Fire Control Panel

Guide System The manufacturer reserves the right to amend specifications without prior notice

Page 31


MIOU LIOU (Lite Version) Multi Input/Output Unit Product Overview - MIOU Occupying less than 20% of the space required by conventional I/O units, the MIOU replaces the large and expensive enclosures normally required for this application.

Features - MIOU Multiple inputs and outputs at one address Opto isolated inputs Volt free contact or switched voltage outputs Considerable space and cost saving over discreet I/O units Easy clip-on din rail mounting method Compatible with Solo, Syncro AS and Syncro control equipment Low standby supply current

With 8 opto-isolated inputs and 8 volt-free relay contacts (relay outputs individually selectable as normally open, normally closed or switched voltage outputs), the MIOU will find a multitude of uses in concentrated I/O applications.

Product Overview - LIOU LIOU Lite provides 4 inputs and 4 outputs to a Hochiki analogue addressable detection loop in a compact and cost effective package. The LIOU Lite can replace up to four addressable modules in approximately the same space taken by one standard module and is ideal for applications where a concentration of I/O is needed in a limited space.

Hochiki ESP protocol

The modules can be addressed with the Hochiki, hand held programmer in the range 1 to 127.

Features - LIOU

All inputs and outputs are fully configurable for any action and for cause and effect via the Syncro Loop Explorer configuration utility.

Four optically isolated inputs Four volt free changeover relay contact outputs 24V DC powered Small footprint Cost effective for concentrated I/O applications Built in short circuit isolator Compatible with Syncro and Syncro AS addressable fire control panels Hochiki ESP protocol

The LIOU connects to the ESP loop as per all other ESP devices. Consider the maximum number of sub-addresses when using LIOU. Each unit has an integral short circuit isolator which provides further cost and space saving.

Note: MIOU & LIOU are currently compatible with Solo, Syncro and Syncro AS control panels only. Note: MIOU & LIOU support Hochiki ESP protocol only. Note: Inputs on MIOU & LIOU are not monitored.

Page 32

LIOU - Model No. K507

MIOU - Din rail mounting version (K559)


DS21.09.2011

Range Product Code

Module

PSU Weight Size (mm)

K559 (Module Only) H66000M2 H66750M2

MIOU MIOU MIOU

750mA

0.3kg 3.6kg 6.8kg

203(L) x 77(W) x 45(D) 385(L) x 310(H) x 90(D) 385(L) x 310(H) x 90(D)

K507 (Module Only) HL66000M2 HL66750M2

LIOU LIOU LIOU

750mA

0.2kg 3.6kg 6.8kg

119(L) x 99(W) 385(L) x 310(H) x 90(D) 385(L) x 310(H) x 90(D)

Specification

Technical - MIOU Boxed unit battery capacity Finish - lid & box Colour - lid & box Boxed unit IP rating Module mounting Communication protocol Supply voltage H6600001 Supply voltage H6675001 Quiescent supply current Input operated current Output operated current Input trigger resistance Output contact rating Switched -ve output Minimum recommended PSU Operating temperature Device sub-address count Address setting

-

2.6Ah 12V (2 per unit) Epoxy powder coated BS 00-A-05 grey - fine texture IP30 Symmetrical or asymmetrical din rail Hochiki ESP 24V DC 110 or 230V AC 50 or 60 Hz. (specify when ordering, default is 230V) 10 milliamps 3 milliamps 18 milliamps 1k maximum 30V DC 1 Amp maximum 65 milliamps maximum per output 750 milliamps at 24V DC -5 to +40 deg. C 17 (of 800 permitted in Syncro / Syncro AS panel) Hochiki hand held programmer (see TB1010)

Boxed unit battery capacity Finish - lid & box Colour - lid & box Module mounting Communication protocol Supply voltage (K507 & HL6600M2) Supply voltage (HL66750M2) Mains fuse for HL67750M2

-

2.6Ah 12V (2 per unit) Epoxy powder coated,

Quiescent supply current Input operated current Output operated current Input trigger resistance Output contact rating minimum recommended PSU Operating temperature Device sub-address count

-

Technical - LIOU

Control Panel

BS 00 A 05 grey - fine texture

4 x 4mm holes in PCB Hochiki ESP 21 to 30V DC

- 230V AC - 20mm ceramic 2A/250V fast

acting 10 milliamps 3 milliamps 18 milliamps 1K maximum 30V DC/2A - 230V AC/0.5A 750 milliamps at 24V DC -5 to +40 deg. C 17 (of 800 permitted in Syncro / Syncro AS panel)

24V DC

LIOU/ MIOU

CHQ-DIM

FIRE BREAK GLASS PRESS HERE

CHQ-DRC

The manufacturer reserves the right to amend specifications without prior notice

Page 33


Syncro iO

16 Channel Input/Output Board

Product Overview To add more I/O capability to the extensive options already offered by the Syncro control panel, up to thirty two, sixteen channel I/O boards may be connected. The 16 channel boards may be mixed on the RS485 bus with 8 way sounder boards, 6 way sounder boards or 4 way conventional detection zone boards to provide a very flexible system of I/O to satisfy any requirement. When using a simple two wire RS485 communications protocol, these boards may be mounted locally to the control panel or distributed on a bus up to 1200 metres long by using a suitable cable.

Features 16 channels Each channel configurable as input or output Inputs opto-isolated Outputs open collector transistor Simple 2 wire connection to control panel Up to 32 boards supported per panel (512 Input/Output Channels) Inputs and outputs configurable as per field devices Full cause and effects on all inputs and outputs Multi drop RS485 communications

The flexibility of these boards is further enhanced by the fact that each of the channels is configurable as either an input or and output. Each channel may also be configured to produce a variety of input actions or respond to a variety of output types. All channels can contribute to, or respond to, system wide cause and effects logic. Typical uses for I/O boards include geographical LED mimic displays and plant alarm inputs. Standard Syncro control panels contain fixings for one sounder, relay, conventional detection or I/O board, which can easily be connected using four small signal wires to the power and comms bus within the panel. Consideration must be taken as to the loading on the main panel.

Can be used with other Syncro I/O modules on the same panel Compatible with Syncro AS panels

Part No. K560

Page 34


DS22.06.2009

Technical Product code Supply voltage Quiescent current consumption Current per input Current per output Communications Maximum distance from panel PCB size Cable capacity Operating temperature Operating humidity

Specification

- K560 - 21 - 30V DC - 20mA -

3mA (maximum) 100mA (maximum) RS485 two wire 1.2Km (using correct type of cable)

-

190mm x 61mm 2.5mm per terminal -10째C to +50째C To 95% (non condensing)

For full technical and application details see the Syncro I/O Board manual

Syncro 16 Channel I/O Board SNDR.1

SNDR.2

SNDR.3

SNDR.4

1

FIRE ROUTING

2

FAULT ROUTING

4

EXTINGUISHER OUTPUT

6

1.

3

5

Syncro Main PCB

REMOTE CONTROL AND AUX. INPUTS

INT

11

5.

SIL

12

0V

13

6. PR1

14

7. PR2

15 16 I/O

AUX 24V

OUT

0V 0V 0V 24V

COMMS OUT 0V

NETWORK OUT

To Next I/O Board

24V Out to next board only if powered from Power Supply & not Aux.24V at panel

TX

REMOTE PSU CHARGER FAULT

EARTH FAULT

MAINS FAIL

RX BATT. DISCONN.

24V

9

4. CNT

NETWORK IN

BATT.LOW

2K2

10

COMMS

24V DC

EXAMPLE OUTPUT

8 I/O CHANNEL

8. PR3

ADDITIONAL I/O BOARDS

0V

7 FLT

2. RES 3.

EXAMPLE INPUT

COMMS IN

0V 24V 0V

IN

The manufacturer reserves the right to amend specifications without prior notice

Page 35


Syncro iO

8 Way Relay Extender Board

Product Overview To further enhance the versatility of the Syncro fire alarm system, additional relay output capability can be added using Syncro relay boards. These boards have 8 voltage free changeover relay contacts, each of which can be individually programmed. Up to 32 of these boards can be connected to the dedicated RS485 communications bus in the control panel giving the capability of up to 256 additional relay outputs.

Features 8 volt free changeover relay contacts (1Amp 30V DC) Relay operated indications Remote connection to panel via RS485 serial bus Common footprint to other Syncro I/O board types All outputs programmable for cause and effects Can be used with other Syncro I/O modules on the same panel Compatible with Syncro AS panels

The relay boards may be mixed on the RS485 bus with 16 channel I/O boards, 6 way sounder boards or 4 way conventional detection zone boards to provide a very flexible system of I/O to satisfy any requirement. All outputs are configurable in the same way as devices connected to the loops and all may be acted upon by cause and effect logic. These boards are typically used in applications which require more than the four standard relay outputs such as signalling to other systems or plant control. Standard Syncro control panels contain fixings for one sounder, relay, conventional detection or I/O board, which can easily be connected using four small signal wires to the power and comms bus within the panel. Consideration must be taken as to the loading on the main panel.

Part No. K547

Page 36


DS33.05.2009

Technical Product code Supply voltage range Quiescent current consumption Operating current (all outputs on) Output contact rating Communications Max. distance from panel PCB size Fixing centres Cable capacity Operating temperature Operating humidity

SNDR.1

SNDR.2

Specification

- K547 - 21 to 30 volts DC - 10mA - 250mA -

SNDR.3

30V DC 1 Amp RS485 two wire 1.2Km (using RS485 data cable) 190mm x 61mm 51.5mm x 180mm 2.5mm per terminal -5째C to +50째C To 95% (non condensing)

SNDR.4

Syncro 8 Way Relay Board O/P 1

FIRE ROUTING

NC O/P 2

NC

FLT

O/P 3

2. RES 3. REMOTE CONTROL AND AUX. INPUTS

INT

NC O/P 4

SIL 0V

NC O/P 5

7. PR2

NC O/P 6

COMMS

C NO

ADDITIONAL I/O BOARDS

NC

AUX 24V

O/P 7

NC O/P 8

NETWORK OUT

CHARGER FAULT

RX 0V 24V 0V

COMMS IN

TX

REMOTE PSU

EARTH FAULT

C NO

OUT

MAINS FAIL

C NO

NETWORK IN

BATT. DISCONN.

C NO

8. PR3

BATT.LOW

C NO

6. PR1

24V DC

C NO

4. CNT 5.

C NO

EXTINGUISHER OUTPUT

Syncro Main PCB

C NO

FAULT ROUTING

1.

NC

Signal to other Systems 30V DC Max. 1 Amp Max.

0V 24V

COMMS OUT 0V

IN

24V Out to next board only if powered from Power Supply & not Aux.24V at panel

Data Out to other Boards

The manufacturer reserves the right to amend specifications without prior notice

Page 37


Syncro iO

6 way Sounder Extender Board

Product Overview To further enhance the versatility of the Syncro fire alarm system, additional sounder output capability can be added using Syncro sounder boards. These boards have 6 monitored sounder outputs, each of which can be individually programmed. In addition to the sounder outputs each board has two general purpose, opto-isolated inputs and two volt-free changeover contact outputs.

Features 6 individually fused and monitored sounder outputs Fault and operated indications 2 opto-isolated general purpose inputs 2 volt free contact general purpose outputs Remote connection to panel via RS485 serial bus Common footprint to other Syncro I/O board types All outputs and inputs programmable for cause and effects Can be used with other Syncro I/O modules on the same panel Compatible with Syncro AS panels

Up to 32 of these boards can be connected to the dedicated RS485 communications bus in the control panel giving the capability of 192 additional sounder outputs with 64 general purpose inputs and 64 general purpose outputs. The sounder boards may be mixed on the RS485 bus with 16 channel I/O boards, 8 way relay boards or 4 way conventional detection zone boards to provide a very flexible system of I/O to satisfy any requirement. All inputs and outputs are configurable in the same way as devices connected to the loops and all may contribute to, or be acted upon by cause and effect logic. These boards are typically used in applications that require more than the four standard sounder outputs such as replacement of existing conventional systems. Standard Syncro control panels contain fixings for one sounder, relay, conventional detection or I/O board, which can easily be connected using four small signal wires to the power and comms bus within the panel. Consideration must be taken as to the loading on the main panel.

Part No. K546

Page 38


DS34.05.2009

Technical

SNDR.1

SNDR.2

SNDR.3

Specification

- K546 - 21 to 30 volts DC - 30mA - 260mA - 10k -

3mA maximum 1 Amp maximum 30V DC 1 Amp RS485 two wire 1.2Km (using RS485 data cable) 190mm x 74mm 51.5mm x 180mm 2.5mm per terminal -5째C to +50째C To 95% (non condensing)

Polarised sounders max. 1 Amp. End of line resistor fitted

SNDR.4

10K

Product code Supply voltage range Quiescent current consumption Full alarm current consumption Sounder current monitoring resistor Current per input Current per sounder output Output contact rating Communications Max. distance from panel PCB size Fixing centres Cable capacity Operating temperature Operating humidity

S1

FIRE ROUTING S2

FAULT ROUTING

Unused outputs must be terminated with end of line resistor to prevent fault indication

S3

1.

S4

FLT

2. RES

Syncro Main PCB

3. REMOTE CONTROL AND AUX. INPUTS

INT

4. CNT 5.

SIL 0V

10K

EXTINGUISHER OUTPUT

Syncro Sounder Board

6. PR1

S5

Max. contact resistance 500 Ohms

S6

I/P1

7. PR2 I/P2

8. PR3

NC

COMMS O/P 1

ADDITIONAL I/O BOARDS

NO

AUX 24V

NC O/P 2

NETWORK IN

TX CHARGER FAULT

EARTH FAULT

MAINS FAIL

BATT. DISCONN.

RX 0V 24V 0V

COMMS IN

OUT

REMOTE PSU

BATT.LOW

C NO

NETWORK OUT

24V DC

C

Signal to other systems max. voltage 30V DC max. current 1 Amp

0V

24V Out to next board only if powered from Power Supply & not Aux.24V at panel

24V

COMMS OUT 0V

Data Out to other Boards

IN

The manufacturer reserves the right to amend specifications without prior notice

Page 39


Syncro iO

4 Way Conventional Detection Zone Module

Product Overview To further enhance the versatility of the Syncro fire alarm system, four conventional detection circuits can be connected with up to 30 detectors per circuit. Conventional control panels can be replaced with this simple module and existing conventional systems can be interfaced directly to modern analogue addressable control systems and networks. A fail safe mode ensures that the detection inputs will still operate the sounder outputs and fire contact if communication to the Syncro panel is lost.

Features 4 monitored detection zone inputs 2 monitored sounder outputs Volt free fire contact Volt free fault contact Local power supply fault input RS485 comms connection to Syncro Fire Alarm Panel Individual fault and operated indications for inputs and outputs Directly replaces a conventional control panel when integrating into an analogue addressable system Can be used with other Syncro I/O modules on the same panel Compatible with Syncro AS panels

Up to 32 of these boards can be connected to the dedicated RS485 communications bus in the control panel giving the capability of up to 128 conventional zones with 64 sounder outputs. The detection zone boards may be mixed on the RS485 bus with 16 channel I/O Boards, 6 way sounder boards or 8 way relay boards to provide a very flexible system of I/O to satisfy any requirement. All inputs and outputs are configurable in the same way as devices connected to the loops and all may be acted upon by cause and effect logic. Standard Syncro control panels contain fixings for one (four way) Detection Zone board, Sounder board, Relay board or I/O board, all of which can easily be connected using four signal wires to the power and comms bus within the panel. Consideration must be taken as to the loading on the main panel.

Part No. K545

Page 40


DS35.05.2009

Technical Product code Supply voltage range Quiescent current consumption Operating current (all outputs on) Output contact rating Detection zone monitoring resistor Sounder circuit monitoring resistor Communications Max. distance from panel PCB size Fixing centres Cable capacity Operating temperature Operating humidity

SNDR.1

SNDR.2

Specification

- K545 - 21 to 30 volts DC - 70mA - 250mA - 30V DC 1 Amp - 6k8 - 10k -

SNDR.3

RS485 two wire 1.2Km (using RS485 data cable) 190mm x 74mm 51.5mm x 180mm 2.5mm per terminal -5째C to +50째C To 95% (non condensing)

SNDR.4

FIRE ROUTING

Syncro 4 Way Conventional Detection Zone Board

FAULT ROUTING EXTINGUISHER OUTPUT

CP

D

Z2

CP

D

CP

D

Z3

D

D

CP

D

Z4

CP

D

CP

D

COMMS

S1

S

S

S

AUX 24V

S2

REMOTE CONTROL AND AUX. INPUTS

4. CNT 5.

SIL 0V

6. PR1 7. PR2 8. PR3

ADDITIONAL I/O BOARDS

FIRE

C

FAULT

NC C

CHARGER FAULT

EARTH FAULT

MAINS FAIL

RX 0V 24V 0V

COMMS IN

NO

TX

REMOTE PSU BATT. DISCONN.

S

NO

NETWORK OUT

BATT.LOW

S

NC

NETWORK IN

24V DC

S

EOL

D

EOL

D

INT

EOL

Z1

3.

EOL

FLT

2. RES

EOL

1.

Syncro Main PCB

PF 0V OUT

IN

24V Out to next board only if powered from Power Supply & not Aux.24V at panel

0V 24V

COMMS OUT 0V

Data Out to other Boards

The manufacturer reserves the right to amend specifications without prior notice

Page 41


DS46.02.2011

Syncro iO

I/O Board Enclosure

Product Overview A range of new enclosures designed to house Syncro I/O modules with or with a power supply. The Syncro I/O enclosure offers the installer the flexibility to create their own customised I/O panel. The standard Syncro I/O enclosure can hold up to 3 Syncro I/O modules or 2, if a power supply is incorporated.

Equipment Product Code Description

Features Matching design & colour scheme for Kentec new style control panel range Easy to install Incorporates Kentec’s “Quick Fit” lid & equipment chassis

K16001M2 K16750M2 K16250M2 K16400M2 Plug-Ins K560 K547 K546 K545

Syncro I/O enclosure without Charger Syncro I/O enclosure c/w 750mA Charger Syncro I/O enclosure c/w 2.5A Charger Syncro I/O enclosure c/w 5.25A Charger 16 Channel Input/Output Board 8 Way Relay Extender Board 6 Way Sounder Extender Board 4 Way Conventional Detection Zone Module

Front panel mounted status led indication Space for 3.2Ah batteries Choice of power supplies

16 Channel Input/Output Board (K560)

8 Way Relay Extender Board (K547)

6 Way Sounder 4 Way Conventional Extender Detection Zone Board (K546) Module (K545)

Choose any combination of I/O boards

2x I/O boards with PSU

3x I/O boards without PSU

Page 42

Model No. K16001M2


DS46.04.2011

Syncro iO

Addressable Sounder Controller Unit Product Overview Syncro addressable sounder controller units enable additional, distributed power and control for sounder circuits in situations where there are insufficient circuits at the fire alarm control panel or where additional power is required to power heavily loaded sounder circuits. Sounder control modules for any of the protocols supported by Syncro are available in a steel enclosure designed to match the appearance of the Syncro fire alarm control panel.

Features

All units contain mains powered battery charger/power supply, they have space for up to 7 Ah batteries.

Two, four or six way units available

Indicators are provided for power healthy and power fault conditions and power fault conditions are signalled to the Syncro fire alarm control panel as a sounder fault.

Integral power supply

Apollo, Argus Vega or Hochiki protocols available

Robust steel enclosure matches Syncro control panel styling Space for 7Ah batteries Power Healthy and Power Fault indicators

Panels

Technical

Product Code

Protocol Sounder PSU Size (mm) Outputs

A1725203 V1725203 H1725203 A1725403 V1725403 H1725403 A1725603 V1725603 H1725603

Apollo XP95 Argus Vega Hochiki ESP Apollo XP95 Argus Vega Hochiki ESP Apollo XP95 Argus Vega Hochiki ESP

Construction Finish Colour - lid & box Colour - labels Mains voltage supply

-

Mains fuse Battery charge fuse Battery Operating temperature Operating humidity Protocol

-

2 2 2 4 4 4 6 6 6

2.5A 2.5A 2.5A 5.25A 5.25A 5.25A 5.25A 5.25A 5.25A

500 x 355 x 108 500 x 355 x 108 500 x 355 x 108 500 x 355 x 108 500 x 355 x 108 500 x 355 x 108 500 x 355 x 108 500 x 355 x 108 500 x 355 x 108

-

1.2mm mild sheet steel Epoxy powder coated BS 00 A 05 grey - fine texture RAL 7047 light grey - satin

110 or 230V AC 50 or 60 Hz. (specify when ordering, default is 230V) 3A, 1¼ inch 20mm x 5mm, 500 milliamp 7Ah 12V (2 per panel) -5°C to +50°C To 95% (non condensing) Apollo XP95, Argus Vega or Hochiki ESP

Model No. #1725203 The manufacturer reserves the right to amend specifications without prior notice

Page 43


N

EW

!

Open connect BMS Communications Interface

Product Overview The all new OpenConnect system provides a simple means of integrating Apollo protocol, Syncro or Syncro AS fire panel networks with a wide range Building Management Systems using any of the commonly used communications protocols.

Features Compatible with all existing Apollo Syncro or Syncro AS fire alarm systems Simple, two wire connection to fire panel Supports LonWorks速, BACnetTM and Modbus protocols Easy to configure interface via a standard web browser Configurable to provide General (network wide) event reporting, event reporting from selected Syncro panels or event reporting from individual Detection Device addresses Individual Syncro Event types (fires, prealarms, disablements, faults etc) can be configured to be passed to the BMS, based on the selected panel reporting options above. Remote reporting only or remote reporting with control options Fully welded steel enclosure to match Syncro fire alarm control panels

Page 44

A simple two wire connection from the fire panel network to the OpenConnect hardware interface and an exported file from the Syncro Loop Explorer configuration programme is all that is needed to realise a working BMS interface simply and quickly. The OpenConnect system allows rapid deployment of a BMS interface due to the use of a standard protocol specifically developed to allow fire panel integration without the need for expensive and time consuming specialist building integration engineering. Once the system is configured, a report is generated containing all of the information on the BMS integrator requires to provide a rapid solution to all BMS integration requirements. Simple 4 step process: 1. Connect OpenConnect hardware to a PC 2. Load configuration file exported from Loop Explorer 3. Set up reporting options required (event types, by zone, by point etc) 4. Print report and hand to BMS integrator


DS66.02.2011 Automation Network/BMS

Loops

Loops

Loops

Interface PCB Fire

Fire

More Events

General Disablement

Power On Pre-Alarm

1

15:05 Tuesday 10 October 2006 KENTEC ELECTRONICS LIMITED

General Fault

On Test

Delay Active

?

2

3

System Fault

Fire in Zone 1

Sounder

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Silence Buzzer

Enter

More Events

Reset

Evacuate

Function

Enable Control

Fire Alarm Control

Re-Sound Alarm

1

15:05 Tuesday 10 October 2006 KENTEC ELECTRONICS LIMITED

General Fault

2

Fire in Zone 1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Enter

More Events

Reset

Evacuate

Function

Enable Control

Re-Sound Alarm

Fire Alarm Control

1 4

System Fault

Fire in Zone 1

Sounder

?

2

3

Power Fault

Delay Active

Lamp Test

15:05 Tuesday 10 October 2006 KENTEC ELECTRONICS LIMITED

General Fault

On Test Buzzer Silenced

Exit

More Fires

16

Fault/Disabled

Silence Buzzer

More Events

Pre-Alarm

3

System Fault Sounder

Silence Alarm (Acknowledge)

General Disablement

Power On

?

4

Power Fault

Buzzer Silenced Delay Active

Lamp Test

Fire

More Events

Pre-Alarm On Test

Exit

More Fires

16

Fault/Disabled

Silence Alarm (Acknowledge)

General Disablement

Power On

4

Power Fault

Buzzer Silenced

Re-Sound Alarm

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Exit

Enter

More Fires

More Events

16

Fault/Disabled

Silence Alarm (Acknowledge)

Silence Buzzer

Lamp Test

Reset

Evacuate

Function

Enable Control

Fire Alarm Control

Model: #80161M2

Model: #80161M2

Model: #80161M2

BS EN54-2 : 1998 BS EN54-4 : 1998

BS EN54-2 : 1998 BS EN54-4 : 1998

BS EN54-2 : 1998 BS EN54-4 : 1998

Fire Alarm Control Panel Network

E N L F2 250V 3A MODEL - S406

24V DC

INPUT VOLTAGE - 230VAC 115VAC FREQUENCY - 50Hz or 60Hz OUTPUT VOLTAGE - 24-29VDC POWER RATING - 4A MAX

EARTH FLT

DC OUT ON

HEART BEAT

AC NORMAL

CHARGER FLT

BATTERY LOW

BATTERY DISCON.

BATTERY

RS485

EN54-4 (1997) + AC (1999) + A1 (2002) + A2 (2006)

OpenConnect interface board (supplied with the OpenConnect kit) to be installed in any Syncro or Syncro AS panel. Note this panel cannot have a printer fitted

BATTERY

BACnet TCP Modus TCP Lonworks FTT10 OpenConnect Gateway Web based user interface

Panels Product Code K8121110 K8121120 K8121111 K8121121 K8221110 K8221120 K8221111 K8221121 K8321110 K8321120 K8321111 K8321121 K8421110 K8421120 K8421111 K8421121

BMS Points provided 200 200 200 200 1600 1600 1600 1600 12000 12000 12000 12000 25000 25000 25000 25000

Ports - Note: 1 x RS485 port is used to interface to the Syncro Panels

Ethernet RS232 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

USB

RS485

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2

Lonworks Size (mm) FTT10 compatible No No Yes Yes No No Yes Yes No No Yes Yes No No Yes Yes

500 x 355 x 117 500 x 355 x 117 500 x 355 x 117 500 x 355 x 117 500 x 355 x 117 500 x 355 x 117 500 x 355 x 117 500 x 355 x 117 500 x 355 x 117 500 x 355 x 117 500 x 355 x 117 500 x 355 x 117 500 x 355 x 117 500 x 355 x 117 500 x 355 x 117 500 x 355 x 117

Technical Operating temperature Operating humidity Supply Voltage

- 0째C to +50째C - 5% to 95% (non condensing) - 230V or 115V AC The manufacturer reserves the right to amend specifications without prior notice

Page 45


Conventional Fire Detection Control Equipment Pages 48-61


Sigma CP EN54 Range Conventional Fire Alarm C/P’s Page 48-49 ! Sigma CP-A NEW Alarmsense Compatible Conventional Fire Alarm C/P’s Page 50-51

Sigma CP-R Conventional Fire Alarm C/P Repeaters Page 52-53 Sigma Sounder Sigma CP Conventional Sounder Controller Units Page 54 EN54-4 Conventional Sounder Controller Units Page 55 K3000 Series Conventional Fire Alarm C/P’s Page 56-57

K3200 Series Conventional Fire Alarm C/P Repeaters Page 58 LCMU Line Continuity Monitoring Unit Page 59

Sigma Matrix Conventional Fire Alarm Mimic System Page 60-61


Sigma CP

BS-EN54-2 BS-EN54-4 KM 73505

Conventional Fire Alarm Control Panels

Product Overview The Sigma CP range consists of a series of conventional fire alarm control panels designed in accordance with European standards BS EN54-2 and BS EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment. The range consists of 2, 4 and 8 zone control panels. All control panels are available in two versions:

Features Fully certified to BS EN54-2 and BS EN54-4 2-wire and standard versions in 2, 4 or 8 zones Compatible for use on BS5839: Part 1: 2002 installations 2-wire repeaters and ancillary boards Fully programmable using simple menu options

Adjustable sounder delay time

Sounder configuration options

Zonal sounder delay detectors only

Zonal sounder delay call points only

Coincidence input selection

Short circuit fire by zone

Non latching zones

Silent zones

Zone input delay

General panel configuration

I.S Barrier selection by zone

Sigma K11 range in which detectors and call points are wired on separate circuits to sounders (two sounder circuits are provided).

Sigma T11 range in which detectors, call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.

Wiring sounders to the detection circuits eliminates the need to install sounder circuit cables and also offers the ability to provide zoned or two stage sounder operation. (T series only) All control panels have an integral, mains powered battery charger and power supply designed in accordance with the requirements of BS EN54-4. Note: For 2-wire T series panels, compatible detectors and call points must be used. All sounders must be polarised. Note: Also available is the Sigma Ancillary Board (K580) which is compatible with all Sigma CP and CP-R panels which have operating software version V2.0 or above. See DS39 (pages 52-53) for more details. Note: Also available is the Sigma Sounder Board (K461) which is compatible with all Sigma CP and CP-R panels which have operating software version V3.0 or above. See DS48 (page 54) for more details.

Simple, single board construction Installer friendly Compatible with wide range of detection devices Two monitored sounder outputs 3 Amp power supply Auxiliary power output

Part No. K580

Page 48

Part No. K461

Model No. K11080M2


DS37.08.2011

Panels Product Code

Description

Standby Current

Alarm Current

Size

K11020M2 K11040M2 K11080M2 T11020M2 T11040M2 T11080M2 K18002

2 zone control panel 4 zone control panel 8 zone control panel 2 zone, 2 wire panel 4 zone, 2 wire panel 8 zone, 2 wire panel Tamper resistant Vision Window *

0.065 Amps 0.075 Amps 0.093 Amps 0.065 Amps 0.075 Amps 0.093 Amps N/A

0.1 Amps 0.21 Amps 0.55 Amps 0.15 Amps 0.3 Amps 0.63 Amps N/A

385 x 310 x 90 385 x 310 x 90 385 x 310 x 90 385 x 310 x 90 385 x 310 x 90 385 x 310 x 90 385 x 310 x 90

Specification

* Vision Window can be easily retrofitted to any Sigma CP panel

90

385

Zone Chart

General System Status

1 2

310

3 4 5

Fire In Zone

Fire

Power Fault

Power On

Sounder Fault/ Disablemen t

Delay On

General Faul t

Test Mode On

System Fault

Genera l Disablement

Alarm/Faul t Warning Silenced

1

2

3

4

System Mode

Zone Fault/Test/Disablement

Fire In Zone 5

6

7

8

Zone Fault/Test/Disablement

Enable Contro l

6 7

Silence/Sound Alar m

Alarm/Fault Warning Silenc e

Rese t

Lamp Tes t

Mode (+10 )

Selec t (+1)

Ente r

8

Fire Alarm Contro l Model: K11080M 2 BS EN54-2 : 199 8 BS EN54-4 : 199 8

KM 73505

Technical Construction Finish Colour - lid & box Colour - controls plate & labels Supply voltage Mains supply fuse Power supply DC rating Maximum battery size Fault contact rating Local fire contact rating Fire contact rating Sounder output rating Detection zone current Detection zone EOL resistor Active EOL Sounder output EOL resistor Cable capacity Operating temperature Operating humidity

-

1.2mm mild sheet steel Epoxy powder coated BS 00 A 05 grey - fine texture RAL 7047 light grey - satin

230V AC (+10%/-15%) 1.6 Amp 250V 24V 3 Amps 7Ah 12V (2 per panel) 30V DC 1 Amp 30V DC 1 Amp 30V DC 1 Amp 0.5A per output (max 1.6A over all outputs) 1.6 milliamps 6k8 5% K14606K (optional) 10k 5% 2.5mm² per terminal -5°C to +50°C <95% (non condensing)

The manufacturer reserves the right to amend specifications without prior notice

Page 49


CP-A

AlarmSense compatible two–wire conventional fire alarm control and indicating panels

Features Fully compliant with BS EN54-2 and BS EN54-4 Allows systems to be installed in accordance with BS5838: Part 6 2 wire systems, reduces installation cabling 2-wire repeaters and ancillary boards via serial bus Fully programmable using simple menu options Adjustable sounder delay time Sounder configuration options Zonal sounder delay for detectors only Zonal sounder delay for call points only Coincidence output via ancillary board Short circuit fire selectable by zone Non latching selection by zone Silent zones (common sounder outputs) Zone input delay for sprinkler system connection AlarmSense® local alarm feature supported Simple, single board construction Installer friendly Compatible with all AlarmSense® devices Two conventional monitored sounder outputs 3 Amp power supply Auxiliary power output

Ancillary PCB Part No. K580

Page 50

Sounder PCB Part No. K461

! N EW

Sigma

Product Overview The new Sigma CP-A AlarmSense® range consists of a series of conventional, 2, 4 and 8 zone fire alarm control panels designed and approved in accordance with European standards BS EN54-2 and BS EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment. The AlarmSense® system enables all devices in a given zone to be wired to the same pair of cables thus greatly reducing the cabling and installation requirements and hence costs. The AlarmSense® range of devices includes smoke and heat detectors, call points, base sounders, base sounder/beacons and relay units – all wired to the same pair of cables. Having sounders and sounder beacons installed on the same cabling as detectors and call points allows all systems to be configured for common, zonal or two stage alarm by simply setting one of the panels configuration options. Selection of the AlarmSense® local alarm feature at sounder or sounder beacon bases invokes the alarm verification feature. This is particularly useful in Houses of Multiple Occupation such as student accommodation or nursing homes. When sounder or sounder beacon bases are selected for local alarm mode, any alarm sounders are restricted such that only the sounder connected to the activated detector will operate initially. The panel will attempt to reset the activated detector after a time delay and if successful no further alarms are sounded. If the detector re-activates after being reset, a general alarm will sound throughout the premises. Activation of a second detector or a call point will sound the general alarm immediately All control panels have an integral, mains powered battery charger and power supply designed and approved in accordance with the requirements of BS EN54-4.

Model No. A11080M2


DS65.02.2011

Panels Product Code

Description

Standby Current

Alarm Current

Size (mm)

KA11020M2 2 zone control panel 0.065 Amps KA11040M2 4 zone control panel 0.075 Amps KA11080M2 8 zone control panel 0.093 Amps

0.1 Amps 0.21 Amps 0.55 Amps

385 x 310x 90 385 x 310 x 90 385 x 310 x 90

Specification

Options Product Code Description K580 K461 M2FCLGT K02000M2 K02750M2 K18002

Stand alone ancillary board Sounder PCB Bezel for semi flushing panel to wall Boxed ancillary board Boxed ancillary board with 0.75A PSU Tamper resistant Vision Window *

* Vision Window can be easily retrofitted to any Sigma CP-A panel 90

385

Zone Chart 1 2

310

3 4 5

General System Status

Fire In Zone

Fire

Power Fault

Power On

Sounder Fault/ Disablemen t

Delay On

General Faul t

Test Mode On

System Fault

Genera l Disablement

Alarm/Faul t Warning Silenced

1

2

3

4

System Mode

Zone Fault/Test/Disablement

Fire In Zone 5

6

7

8

Zone Fault/Test/Disablement

Enable Contro l

6 7

Silence/Sound Alar m

Alarm/Fault Warning Silenc e

Rese t

Lamp Tes t

Mode (+10 )

Selec t (+1)

Ente r

8

Fire Alarm Control Model: KA11080M2

Technical Construction Finish Colour - lid & box Colour - controls plate & labels Supply voltage Mains supply fuse Power supply DC rating Maximum battery size Fault contact rating Local fire contact rating Fire contact rating Common Sounder output rating AlarmSense Sounder output rating Detection zone current Detection zone EOL resistor Sounder output EOL resistor Cable capacity Operating temperature Operating humidity

-

1.2mm mild sheet steel Epoxy powder coated BS 00 A 05 grey - fine texture RAL 7047 light grey - satin 230V AC (+10%/-15%) 1.6 Amp 250V 24V 3 Amps 7Ah 12V (2 per panel) 30V DC 1 Amp 30V DC 1 Amp 30V DC 1 Amp 0.5A per output 0.2A per output 1.6 milliamps 3K3 5% 10k 5% 2.5mm² per terminal -5°C to +50°C <95% (non condensing)

The manufacturer reserves the right to amend specifications without prior notice

Page 51


Sigma

CP-R

& Ancillary PCB Conventional Fire Alarm Control Panel Repeaters

Sigma CP-R

Product Overview The Sigma CP-R Repeater is compatible with all Sigma CP control panels which have operating software version V2.0 or above. Repeaters are available with 2, 4 or 8 zones and in mains powered (K versions) or 24V powered (E versions).

Ancillary PCB

Product Overview The Sigma Ancillary Board is compatible with all Sigma CP and CP-R panels which have operating software version V2.0 or above. The board provides common fire, common fault, coincidence and zonal fire, volt free contacts allowing control of sub-systems, graphical mimics and plant, remotely from the main panel over a two wire data bus. Mains powered Ancillary boards require only a two core data cable from the main control panel. 24V DC versions require an additional two cores for power either from the main panel or from another 24V DC source. A mixture of Ancillary boards, Sounder boards or Repeaters up to a maximum of 7 of each type can be connected to a control panel and each is allocated an address from 1 to 7 using a binary coded DIL switch. The total length of the data cable from the main panel to the last repeater must not exceed 1200 metres.

Ancillary PCB

Mains powered repeaters require only a two core data cable from the main control panel. 24V DC versions require an additional two cores for power either from the main panel or from another 24V DC source. A mixture of Repeaters, Ancillary boards or Sounder Boards up to a maximum of 7 of each type can be connected to a control panel and each is allocated an address from 1 to 7 using a binary coded DIL switch. The total length of the data cable from the main panel to the last repeater must not exceed 1200 metres.

Sigma CP-R

Features Two wire serial connection Up to 7 panels per system 230V AC or 24V DC powered versions Full control over main panel Volt free fire and fault contact outputs Note: Also available is the Sigma Sounder Board (K461) which is compatible with all Sigma CP and CP-R panels which have operating software version V3.0 or above. See DS48 (page 54) for more details.

Features

Two wire serial connection Up to 7 boards per system 230V AC or 24V DC powered versions Open collector zonal fault outputs Volt free fire, coincidence and common fault contact outputs

Part No. K580

Page 52

Model No. E01080M2


DS39.05.2011

Power Connection Zonal Volt Free Contacts Data Connection

+ 24V DC

NO C NC NO C NC NO C NC COINC FAULT FIRE Z8 RELAY RELAY RELAY FIRE

Specification

+ - + Z7 FIRE

Z6 FIRE

Z5 FIRE

Z4 FIRE

Z3 FIRE

Z2 FIRE

Z1 FIRE

RS485 RS485 OUT IN

K580 Sigma CP Ancillary PCB

OK

COMMS

FUSE FAIL

PROCESSOR RESET

ADDRESS

Address Switch Processor Reset Switch

Equipment Product Code

Description

Supply Voltage

Standby Current

Alarm Current

E01020L2 E01040L2 E01080L2 K01020M2 K01040M2 K01080M2

2 zone Sigma CP-R repeater panel 4 zone Sigma CP-R repeater panel 8 zone Sigma CP-R repeater panel 2 zone Sigma CP-R repeater panel with PSU 4 zone Sigma CP-R repeater panel with PSU 8 zone Sigma CP-R repeater panel with PSU

24V DC 24V DC 24V DC 230V AC 230V AC 230V AC

0.075 Amps 0.075 Amps 0.075 Amps 0.075 Amps 0.075 Amps 0.075 Amps

0.094 Amps 0.098 Amps 0.11 Amps 0.094 Amps 0.098 Amps 0.11 Amps

385 x 310 x 60 385 x 310 x 60 385 x 310 x 60 385 x 310 x 90 385 x 310 x 90 385 x 310 x 90

K580 K02000M2 K02750M2 K18002

Stand alone ancillary board Boxed ancillary board Boxed ancillary board with 0.75A PSU Tamper resistant Vision Window *

24V DC 24V DC 230V AC N/A

0.020 Amps 0.020 Amps 0.020 Amps N/A

0.2 Amps 0.2 Amps 0.2 Amps N/A

155 x 136 385 x 310 x 90 385 x 310 x 90

Size

(mm)

* Vision Window can be easily retrofitted to any Sigma CP-R panel

Sigma CP-R

Ancillary PCB

Technical Construction Finish Colour - lid & box Colour - Controls plate & labels Supply voltage (K models) Supply voltage (E models) Mains supply fuse Power supply DC rating Maximum battery size Fault contact rating Fire contact rating Cable capacity Operating temperature Operating humidity

Technical -

1.2mm mild sheet steel Epoxy powder coated BS 00 A 05 grey - fine texture RAL 7047 light grey - satin

-

230V AC (+10%/-15%) 20-30V DC 1.6A 250V 24V 1 Amps 7Ah 12V (2 per panel) 30V DC 1 Amp 30V DC 1 Amp 2.5mm² per terminal -5°C to +50°C <95% (non condensing)

Construction (boxed) Finish Colour - lid & box Colour - controls plate & labels Supply voltage (K02750M2) Supply voltage (K02000M2) Mains supply fuse Power supply DC rating Maximum battery size Standby current Full alarm current Fault contact rating Fire contact rating Coincidence contact rating Zonal contact rating Cable capacity Operating temperature Operating humidity

-

1.2mm mild steel Epoxy powder coated BS 00 A 05 grey - fine texture RAL 7047 light grey - satin 230V AC (+10%/-15%) 20-30V DC 1.6A 250V 24V 750mA 2.6Ah 12V (2 per panel) 20mA 190mA 30V DC 1 Amp 30V DC 1 Amp 30V DC 1 Amp 30V DC 1 Amp 2.5mm² per terminal -5°C to +50°C <95% (non condensing)

The manufacturer reserves the right to amend specifications without prior notice

Page 53


Sigma

Sounder

Product Overview

Sigma CP Conventional Sounder Controller Units

The Sigma CP Sounder Board is compatible with all Sigma CP control panels which have operating software version V3.0 or above. The board provides 8 additional sounder outputs which can be configured as zoned, 2-stage or common alarm. All sounder outputs are open and short circuit monitored and any faults on the sounder outputs will be announced at the main fire alarm panel as a sounder fault. A class change input is provided which, when activated by a volt free contact closing, will switch all sounder outputs on.

Features Two wire serial connection Up to 7 sounder boards per system 230V AC or 24V DC powered versions Zoned, 2-stage or common alarm All outputs monitored for open and short circuit faults Individual open and short circuit fault indicators Fully monitored by main control panel Class change input facility Up to 8 outputs with 1A available from each Can be connected to serial bus with Ancillary boards and repeaters Boxed units in enclosure to match Sigma CP control panels Power fault input for monitoring remote power supplies

Mains powered units require only a two core data cable from the main control panel. 24V DC versions require an additional two cores from another 24V DC source which is suitably rated to supply the total sounder current. 230V versions have their own power supply which is rated to supply sounder loads up to 5.25 Amps. Up to 7 Sounder boards can be connected to a control panel and each is allocated an address from 1 to 7 using a binary coded DIL switch. Sounder boards may be connected to the Sigma CP serial bus in addition to Sigma CP ancillary boards and Sigma CP-R repeater panels. The total length of the data cable from the main panel to the last repeater must not exceed 1200 metres. Once Sounder boards have been recognised by the main panel, a fault will be announced at the main panel if any become disconnected.

Panels Product Code Description K461 K04000M2 K04400M2

Technical Construction (Boxed) Finish Colour - lid & box Supply Voltage (K04400M2) Supply Voltage (K04000M2) Mains supply fuse Power supply DC rating Sounder output rating Class change input Cable capacity Operating temperature Operating humidity

-

PSU

Size (mm)

24V DC 155 x 136 Stand alone sounder PCB Boxed sounder PCB 24V DC 385 x 310 x 90 Boxed sounder PCB 230V DC 385 x 310 x 90 with 5.25 Amp PSU

1.2mm mild steel Epoxy powder coated BS 00 A 05 grey - fine texture

230V AC (+10%/-15%)

- 20-30V DC -

1.6A 250V 24V 5.25 Amp 1A per output Volt free NOC 2.5mm² per terminal -5°C to +50°C <95% (non condensing)

Model No. K04400M2

Page 54


DS48.05.2011

Sounder Controller Conventional Sounder Controller Units

Product Overview Conventional Sounder controllers enable additional, distributed power and control for sounder circuits in situations where there are insufficient circuits at the fire alarm control panel or where additional power is required to power heavily loaded sounder circuits. The Sounder Controller Unit connects to conventional sounder circuits and any faults on its outputs are transmitted to the fire control panel via the incoming, triggering sounder circuit thus maintaining full fault monitoring. All units contain a mains powered battery charger/power supply. There is space for up to 7 Ah batteries. Indicators are provided for power healthy, power fault and sounder fault conditions and power fault conditions are signalled to the fire alarm control panel as a sounder fault.

Features Two four or six way units available Integral power supply

Panels

Robust steel enclosure

Product Code Description

PSU

Size (mm)

Space for 7Ah batteries

K1740203

5.25A

500 x 355 x 108

Power Healthy, Power Fault and Sounder Fault indicators

5.25A

500 x 355 x 108

Full fault monitoring and integrity maintained

5.25A

500 x 355 x 108

K1740403 K1740603

2 Way Sounder Controller Unit 4 Way Sounder Controller Unit 6 Way Sounder Controller Unit

Technical Construction Finish Colour - lid & box Supply voltage Mains fuse Battery charge fuse Power output Battery Operating temperature Operating humidity

-

1.2mm mild sheet steel Epoxy powder coated BS 00 A 05 grey - fine texture

230V AC (+10%/-15%) 3A, 1¼ inch 20mm x 5mm, 500 milliamp 24V at 2.5A 7Ah -5°C to +50°C To 95% (non condensing)

Model No. K1725203 The manufacturer reserves the right to amend specifications without prior notice

Page 55


Series

3000

Conventional Fire Alarm Control Panels

Product Overview The K3000 Series exceeds the requirements of BS5839: Part 4: 1988 in several areas. Inclusion of zone isolate, zonal one man test, zonal contacts, shop unit interface and zoned or two stage alarm outputs are all standard features.

Features Complies with BS5839: Part 4: 1988 Can be used on pre BS5839 type systems 12 - 48 zones as standard more available on request Class change input Common fire and fault contacts Line continuity upon detector removal Remote signal contact and isolate

A wide range of detectors are supported by the equipment, ensuring that the K3000 Series control panels can be used with existing installations without the need to change the field devices. Front panel controls and indicators are kept to a minimum to simplify user operation and to maintain clarity of indication. High intensity, twin bar LED indicators are used on all front panels. All panels are supplied with suitable power supply and generous battery space to give extended battery standby if required. Ample cable entries and removable chassis assist in ease of installation. All panels are available as true flush or surface mounting and in two tone grey or cream and brown. Other colours are available to special order. Arrangements can be made for special badging or special finishes such as brass or stainless steel. K3000 Series control panels allow continued operation of call points and detectors upon removal of a device from the detection line. This can be achieved either by fitting an active end of line device or by using special line clamping bases.

Shop interface input Zonal one man test Zonal selection for operation with intrinsically safe barriers Zonal volt free contacts Zone isolate facility Compatible with most popular detectors Option for plug-in two stage sounder cards

Model No. K3024005

Page 56


DS01.11.2011

Specification Control Panel

Wall Flush mount cross section

Panels Product Zones Standby Alarm Sounder Sounder Minimum Current Current Load per Load Battery Code (24h standby) Circuit total

PSU

E3012003 K3016005 E3016005 K3024005 E3024005 K3032007 E3032007 K3040007 K3048009

2.5A 4.0A 2.5A 4.0A 2.5A 4.0A 2.5A 4.0A 4.0A

12 16 16 24 24 32 32 40 48

0.2A 0.22A 0.22A 0.31A 0.31A 0.38A 0.38A 0.45A 0.52A

0.34A 0.38A 0.38A 0.45A 0.45A 0.52A 0.52A 0.59A 0.66A

1.0A 1.0A 1.0A 1.0A 1.0A 1.0A 1.0A 1.0A 1.0A

1.5A 1.5A 1.0A 1.5A 1.0A 1.5A 1.0A 1.5A 1.5A

7.0Ah 7.0Ah 7.0Ah 12.0Ah 12.0Ah 12.0Ah 12.0Ah 15.0Ah 17.0Ah

Weight Size (mm) (approx)

8.6kg 11.0kg 11.0kg 11.5kg 11.5kg 20.0kg 20.0kg 20.5kg 24.0kg

500 x 355 x 108 570 x 420 x 110 570 x 420 x 110 570 x 420 x 110 570 x 420 x 110 600 x 700 x 140 600 x 700 x 140 600 x 700 x 140 700 x 1000 x 145

Flush mounting versions are available to order. All weights quoted are less standby batteries

Technical Construction Finish Standard colour Sounder outputs Isolatable fire contact Auxiliary alarm contact Fault contact Zonal contacts Auxiliary DC output Detection zone monitoring resistor Sounder circuit monitoring resistor Remote control inputs

-

Mains supply

- 230V AC (+10%/-15%)

Call points Alarm threshold Short circuit threshold Maximum zone quiescent current Active end of line Operating temperature Operating humidity

-

1.2mm mild sheet steel Epoxy powder coated BS 00 A 05 grey - fine texture 2 outputs each fused at 1 amp each (0.5A E3002001) Volt free changeover 1A at 30V DC Volt free changeover 1A at 30V DC Volt free changeover 1A at 30V DC Volt free normally open 1A at 30V DC Fused at 500mA 6k8

- 10k - Alarm input, Silence input, Reset input

(option for pulsed alarm input [Security Alert]) (other voltages upon request) Require 470 OHM series resistor 100 to 900 Ohms 0 to 100 Ohms 1.6mA

- K1406K (optional) - -5째C to +40째C - To 95% (non condensing) The manufacturer reserves the right to amend specifications without prior notice

Page 57


DS02.11.2011

Series

3200

Conventional Fire Alarm Control Panel Repeaters

Product Overview The K3200 series repeater panel uses a similar layout to the main control panel and is fitted with the same high quality indicators. In their discrete enclosure, they are well suited to areas where space is limited and aesthetics are an important consideration. As well as zonal fire indicators, system fault, system healthy and buzzer muted indicators are provided. Controls are kept to the practical minimum of lamp test and buzzer mute. Subsequent alarm or fault conditions whilst the buzzer is muted will resound the buzzer to alert personnel to changing conditions.

Features Zonal fire indicators Common fault and power on indicators Lamp test push button

Repeat panels are available as true flush or surface mounting and in two tone grey or cream and brown as standard. Other colours are available to special order. Arrangements can be made for special badging or special finishes such as brass or stainless steel. Special repeater panels can be made to order.

Internal buzzer with mute facility Buzzer resound facility

Technical Equipment Product Code K3212001 K3216001 K3224001 K3232003 K3240005 K3248005

Zones Weight Size (mm) 12 16 24 32 40 48

3.5kg 6.0kg 6.0kg 8.0kg 10.5kg 10.5kg

Construction Finish Colour Voltage Power consumption Operating temperature Operating humidity

-

1.2mm mild sheet steel Epoxy powder coated BS 00 A 05 grey - fine texture 20V - 30V DC 20mA per zone -5 to +50 deg. C To 95% (non condensing)

365 x 290 x 88 365 x 290 x 88 365 x 290 x 88 500 x 355 x 108 570 x 420 x 110 570 x 420 x 110

Flush mounting versions are available to order, see price guide

Model No. K3212001

Page 58


DS20.09.2011

LCMU Line Continuity Monitoring Unit

Product Overview To use this method of monitoring, the breaking connection of the detector base must be fitted with a diode. To ensure correct operation over a wide supply voltage range and with up to 20 detectors removed, a Schottky type BYV-1060 is recommended. These devices are, however, very sensitive to electrostatic discharge and extra care should be taken when handling or cable testing. It is also necessary to fit a 47uF capacitor to the detection line terminals on some of the control panels (not K3000 series or Sigma CP). Extreme care should be taken when fitting the capacitor in the panel as they are polarity conscious. The LCMU itself is also polarity conscious and the polarity is indicated in the normal manner i.e. black wire is always negative. A wrongly connected LCMU will produce a short circuit fault condition.

Features Easy to install

Due to the use of surface mount technology components, the LCMU is probably the smallest device of its kind on the market. This enables the device to be fitted either within the last device on a zone or in the back box, eliminating the need for an additional wiring point.

No additional wiring point Low cost Sub-miniature design Environmentally sealed

Technical Finish Colour Normal current Fault condition current Max. zone cable resistance Panel capacitor Operating voltage Terminal connections Max. detectors supported Lead colours

-

Conformal powder coating Blue 5mA at 28V 750uA 50V 20 ohms 47uF 50V 15V to 30V Bootlace ferrules 20 per zone K1406K - pink/black K1406C - orange/black K1406N - red/black

Panels Product Code Description Line Continuity Monitoring Unit 6k8 Line Continuity Monitoring Unit 5k6 Line Continuity Monitoring Unit 3k9

K14060 NF14060 KID14060

Size (m) 25 x 20 x 8 25 x 20 x 8 25 x 20 x 8

Not required on K3000 series or Sigma CP panels

DETECTOR

DETECTOR

470R

470R

CALL POINTS

CALL POINTS

Z 47uF Z

CONTROL PANEL

LAST DEVICE ON ZONE

LCMU

The manufacturer reserves the right to amend specifications without prior notice

Page 59


Sigma

Matrix

Conventional Fire Alarm Mimic System

Product Overview The Sigma Matrix system uses flexible, fibre optic light guides to illuminate areas on a floor plan, laid over a high resolution grid. This unique system dispenses completely with wiring and enables indicators to be moved, removed or added on site without the need for any wiring.

Features Up to 320 LED’s can be controlled Full colour printing Available in a range of standard enclosures to suit any application Bespoke sized units can be made upon request

All indicators can be configured to operate via switched positive or negative inputs providing compatibility with a wide range of input/output boards. Sigma Matrix can be supplied with or without common LEDs and controls. Optional LEDs indicate Power on, Fire and Fault and optional controls are for Buzzer silence and Lamp test. Housed in attractive, slimline enclosures to match Sigma fire alarm panels and with high quality, full colour or monochrome floor plans, Sigma Matrix provides a clear, geographical indication of fire alarm activation enabling speedy identification of the source of an alarm.

Choice of Red, Green or Yellow LED’s Available with or without controls Same look and feel as Sigma range Sigma Matrix can easily be upgraded on site with minimal cost and effort EN54-4 approved PSU (optional)

View showing mimic mounted on inner door

View showing LED grid

View showing internal layout

PSU optional

Page 60

M3 size Sigma Matrix


DS59.02.2011

Specification

Technical Construction Finish Colour - lid & box Colour - controls plate & labels Mimic Number of indicators (standard models) Mains supply* Mains supply fuse* Power supply rating* Maximum ripple current* Battery type* (Yuasa NP) Battery charge voltage* Battery charge current* Max. current draw from batteries* Supply voltage (24V versions) Terminal capacity Cabinet locks Maximum distance from control panel IP rating Operating temperature

-

1.2mm mild steel Epoxy powder coated BS 00 A 05 grey - fine texture RAL 7047 light grey - satin

3mm Clear Anti-Glare Acrylic M2 size - up to 32, M3 and S3 size - up to 64, S4 size - up to 96 230V AC +10% - 15% (100 Watts max.) T2A L250V Replace only with similar type 5.25 Amps total including battery charge 28V +/ 2V 200 millivolts Two 12 Volt sealed lead acid (7Ah maximum) 27.6VDC nominal (temperature compensated) 1.5A maximum 3 Amps. With mains power source disconnected 18 to 30V DC 0.5mm2 to 2.5mm2 solid or stranded wire M2/M3 - standard 801 key, S3/S4 - standard KT3001 key 1km with 1.5mm2 cable

- IP30 - -5°C to +50°C

* 230 V Versions only

Enclosure Size Options Max. number of LED’s = 32

Max. number of LED’s = 64

Will house 1 x 32 LED driver PCB

Will house 1 x LED driver PCB and 1 x 32 LED extension PCB’s

Max. number of LED’s = 64

Max. number of LED’s = 320

Max. number of LED’s = 96

Will house 1 x 32 LED Will house 1 x 32 LED driver PCB and driver PCB and 2 x 32 LED 1 x 32 LED extension PCB’s extension PCB’s

Will house 1 x 32 LED driver PCB and up to 9 x 32 LED extension PCB’s

(Red, Green or Yellow) (Red, Green or Yellow) (Red, Green or Yellow) (Red, Green or Yellow)

(Red, Green or Yellow)

Bespoke Size S4

? ?

M3 S3

M2 303

185

385mm x 310mm 90mm Deep

400

515 400

400 303 225

500mm x 355mm 117mm Deep

385mm x 520mm 110mm Deep

500mm x 650mm 137mm Deep

Colour/Finish & Size to suit your requirements

The manufacturer reserves the right to amend specifications without prior notice

Page 61


Extinguishant System Control Equipment Pages 64-81


Sigma XT EN12094 Extinguishant Control Panels Page 64-65 Sigma XT+ Multi Area Extinguishant Control Panels Page 66-67 Sigma XT+ Extinguishant Coincidence Unit Page 68-69

Sigma Si Status Units and hold off switch for use with Sigma XT/XT+ Page 70-71 Sigma XT Ancillary PCB Extinguishant Ancillary PCB Page 72-73

Syncro XT+ Multi Area Addressable Extinguishant Control Panels Page 74-75

COMING SOON

Sigma A-XT NEW! UL Listed FM Approved Extinguishant Control Panels Page 76-77 Sigma A-Si NEW! Status Units and abort switch for use with Sigma A-XT Page 78-79 Sigma A-XT Ancillary PCB UL Listed FM Approved Extinguishant Ancillary PCB Page 80-81

NEW!


Sigma BS-EN12094-1 KM 96761

Extinguishant Control Panel

XT

Product Overview Designed and manufactured to the highest standards in a quality controlled environment and with European EN12094-1 approvals, the Sigma XT extinguishant releasing panel offers outstanding value and performance for all small to medium fixed firefighting installations.

Features Complies with EN12094-1 Three detection zones as standard Any single zone or any combinations of zones can be configured to release Configurable first stage sounder delays Configurable detection delays Zero time delay upon manual release option Compatible with I.S. barriers Non-latching zone input option to receive signals from other systems such as aspirating equipment Configurable extinguishant delays up to 60 seconds in 5 second steps Configurable extinguishant duration up to 5 minutes in 5 second steps

With three detection zones as standard, extinguishant release can be configured to activate from any combination of detection zone inputs to allow (among other combinations) any two from three type activations such as would be required for detection in ceiling void, room and floor void applications. The extensive configuration options of the Sigma XT allow the functionality of the system to be extensively modified while still complying with the requirements of the controlling standard for the equipment (EN12094-1). The panel contains a large LED display to enable easy configuration and control which also displays the time remaining until extinguishant release for added user safety. The countdown timer is duplicated on up to seven remote status units to provide local indication of the extinguishant system status. With all of the electronics mounted on a single, easily removable, steel plate Sigma XT panels are both robust and easy to install. Sigma XT is supplied in an enclosure that matches the design and colour of the Sigma CP range.

Countdown timer shows time remaining until release Supports up to seven, four wire status indicators Built in Extract Fan control

Programmable Functions Access Level 2

Test Zones 1 to 3 Disable Zones 1 to 3 Disable 1st Stage Alarms Disable Pre-activated 1st Stage Relay Disable Pre-activated 2nd Stage Relay Disable Extract Fan Output Disable Manual Release Input Disable Extinguishant Sub System Activate Extract Fan Output Activate Alarm Delays

Access Level 3

Page 64

Sounder Delay Coincidence Detection Disable Panel Features Zone Alarm Delays (Detectors) Zone Alarm Delay (Call Points) Configure Zone for I.S Barrier Use Zone Short Circuit Alarm Zone Non Latching Zone Inputs Delay Extinguishant Release Time Delay Extinguishant Release Duration Timer Extinguishant Reset Delay Timer

Model No. K11031M2


DS40.06.2011

Technical Construction Finish Colour - lid & box Colour - controls plate & labels Mains supply Mains supply fuse Power supply rating Maximum ripple current Battery type (Yuasa NP) Battery charge voltage Battery charge current Battery fuse Maximum current draw from batteries Quiescent current of panel in mains fail R0V output Sounder outputs Fault relay contact rating Fire relay contact rating Local fire relay contact rating First stage contact rating Second stage contact rating Extract contact rating Zone quiescent current Terminal capacity Number of detectors per zone Number of sounders per circuit Detection circuit end of line Monitored input end of line Sounder circuit end of line Extinguishant output EOL No. of detection circuits No. of sounder circuits Extinguishant release output Extinguishant release delay Extinguishant release duration SIL, AL, FLT, RST inputs Zone normal threshold Detector alarm threshold Call point alarm threshold Short circuit threshold Head removal condition Cabling Monitored inputs normal threshold Monitored inputs alarm threshold Monitored inputs Short circuit threshold Status unit/Ancillary board connection Status unit power output

-

1.2mm mild sheet steel Epoxy powder coated BS 00 A 05 grey - fine texture RAL 7047 light grey - satin 230V AC +10%/-15% (100 Watts maximum) 1.6 Amp (F1.6A L250V) 3 Amps total including battery charge 28V +/- 2V 200 millivolts Two 12 Volt 7Ah sealed lead acid in series 27.6VDC nominal (temperature compensated) 0.7A maximum 20mm, 3.15A glass 3 Amps 0.095A Fused at 500mA with electronic fuse 24V Fused at 500mA with electronic fuse 30VDC 1A Amp maximum 30VDC 1A Amp maximum 30VDC 1A Amp maximum 30VDC 1A Amp maximum 30VDC 1A Amp maximum 30VDC 1A Amp maximum 2mA maximum 0.5mm² to 2.5mm² solid or stranded wire Dependent on type (maximum 32) Dependent on type (max. 0.5A per sounder circuit) 6K8 5% ½ Watt resistor 6K8 5% ½ Watt resistor 10K 5% ¼ Watt resistor 1N4004 Diode 3 2 x 1st Stage, 1 x 2nd Stage Fused at 1 Amp Adjustable 0 to 60 seconds (in 5 second steps) Adjustable 60 to 300 seconds (in 5 second steps) Switched -ve, max resistance 100 Ohms 8K ohms to 1K ohm 999 ohms to 400 ohms 399 ohms to 100 ohms 99 ohms to 0 ohms 15.5 to 17.5 volts FP200 or equivalent 8K ohms to 1K ohm 999 ohms to 100 ohms 99 ohms to 0 ohms Two wire RS485 connection Fused at 500mA with electronic fuse

Specification

R0V SIL AL FLT RST AUX REMOTE DATA POWER 24V CONTROL STATUS UNITS

S1

S2

S

S

S

S

6K8

S

Extract Fan Power

Releasing Solenoid

Extinguishant Low Pressure Switch 470R

Remote Hold Switch

Extinguishant Released Pressure Switch 470R

Remote Manual Release Switch

470R

DIODE

S O L

6K8

S

6K8

S

6K8

To Status Units

6K8

Releasing Detectors

Peripheral Detectors

10K

6K8

Remote Control Inputs

E

2nd Stage Sounders

10K

6K8

1st Stage Sounders 10K

Remote Auto/Manual Select Switch

385 x 310 x 90 415 x 315 x 86

470R

Surface mounting panel Flush mounting panel

6K8

Size (mm)

Shutdown Power

K11031M2 K11031F2

Description

Stop Air Conditioning

Product Code

470R

Panels

Auxiliary Signalling Relays

S

NC C NO NC C NO NO C NC C NO NC C NO NC C NO ZONE 1 ZONE 2 ZONE 3 2ND 1ST 2ND MODE MAN. HOLD REL EXTING. LOW EXTRACT FAULT LOCAL FIRE SOUNDER STAGE STAGE SELECT RELEASE PRESS. PRES. RELAY FIRE RELAY SWITCH SWITCH

Sigma XT PCB

The manufacturer reserves the right to amend specifications without prior notice

Page 65


Sigma XT+

Multi- Area Extinguishant Control Panels

Features Complies with EN12094-1

Product Overview Sigma XT+ control panels are multi-area extinguishant control panels complying with EN12094-1. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface. All extinguishant areas may have up to 7, serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable.

2, 4 or 8 detection zones 1 to 4 extinguishant areas Dual extinguishant outputs for each area (configurable as Main/Reserve) First and second stage sounder outputs for each area First and second stage volt free changeover contacts for each area

The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards (K580) or Sigma CP Sounder boards (K461) to the RS485 serial bus. See data sheet DS39 (page 52-53) and DS48 (page 53-54). For compatible status units see Sigma Si data sheet DS41 (page 70-71).

Released volt free contact per area Fault volt free contact per area Programmable extinguishant delays Programmable output duration Extract fan control Countdown indicator shows time until release in seconds Mode select and manual release controls per area Monitored remote manual release input Monitored remote Hold input Monitored remote Mode select (door interlock) input Monitored remote Released pressure switch input Monitored remote Low Pressure switch input Monitored Abort input Serial connection for Sigma Si status units and ancillary boards. (K588) Model No. K21082M3

Page 66

Sigma XT Ancillary Board - K588

Sigma CP Ancillary Board - K580

Sigma CP Sounder Board - K461


DS50.03.2011

Specification

Panels Product Code Zones Areas Size (mm) K21021M3 K21041M3 K21042M3 K21081M3 K21082M3 K21083M4 K21084M4

2 4 4 8 8 8 8

1 1 2 1 2 3 4

385 x 520 x 110 385 x 520 x 110 385 x 520 x 110 385 x 520 x 110 385 x 520 x 110 385 x 700 x 145 385 x 700 x 145

Technical Construction Finish Colour - lid & box Colour - controls plate & labels Mains supply Mains supply fuse Power supply rating (1 & 2 area units) Power supply rating (3 & 4 area units) Maximum ripple current Battery charge voltage Battery charge current Battery fuse Current draw in mains fail condition Max. current draw from batteries

-

Sigma XT+ module Aux 24V output Sigma CP Aux 24V output 1st and 2nd stage Sounder outputs Fault relay contact rating Fire relay contact rating Local fire relay contact rating First stage contact rating Second stage contact rating Extract contact rating Zone quiescent current Terminal capacity Number of detectors per zone Number of sounders per circuit Detection circuit end of line Monitored input end of line Sounder circuit end of line Extinguishant output end of line No. of detection circuits No. of sounder circuits Extinguishant release output Extinguishant release delay Extinguishant release duration SIL, AL, FLT, RST inputs Zone normal threshold (Allowable EOL) Detector alarm threshold Call point alarm threshold Short circuit threshold Head removal condition Cabling Monitored inputs normal threshold (Allowable EOL) Monitored inputs alarm threshold Monitored inputs Short circuit threshold Status unit/Ancillary board connection Status unit power output

-

230V AC, 50Hz +10% - 15% (100 Watts maximum) 1.6 Amp ( F1.6A L250V) 3 Amps total including battery charge 28V +/- 2V 5.25 Amps including battery charge 28V +/- 2V 200 millivolts 27.6VDC nominal (temperature compensated) 0.7A maximum 20mm, 3.15A glass 54 milliamps per module 3A (K21021, K21041, K21042, K21081, K21082) 4A (K21083, K21084) Fused at 500mA with electronic fuse - 1 per extinguishant area Fused at 2.5A - not available to user 21 to 28V DC Fused at 1A with electronic fuse 5 to 30VDC 1A Amp maximum for each 5 to 30VDC 1A Amp maximum for each 5 to 30VDC 1A Amp maximum for each 5 to 30VDC 1A Amp maximum for each 5 to 30VDC 1A Amp maximum for each 5 to 30VDC 1A Amp maximum for each 0mA minimum, 2mA maximum 0.5mm2 to 2.5mm2 solid or stranded wire Dependent on type - typically 20 Dependent on type and current consumption - typically 20+ 6K8 +/- 5% ½ Watt resistor 6K8 +/- 5% ½ Watt resistor 10K +/- 5% ¼ Watt resistor 1N4004 Diode Two to eight. 21 to 28V DC Dependent on model 21 to 28V DC 21 to 28V DC. Fused at 1 Amp Adjustable 0 to 60 seconds (+/- 10%) Adjustable 60 to 300 seconds Switched -ve, min resistance 0 ohms, max resistance 100 Ohms 10K ohm to 2K ohm 1K ohms to 390 ohms 370 ohms to 150 ohms 130 ohms to 0 ohms 15.5 to 17.5 volts FP200 or equivalent (max capacitance 1uF max inductance 1 mH 10K ohm to 2K ohm

-

2K ohms to 150 ohms +/- 5% 140 ohms to 0 ohms +/- 5% Two wire RS485 connection (EIA-485 specification) 21 to 28V DC. Fused at 500mA with electronic fuse

1.2mm mild sheet steel Epoxy powder coated BS 00 A 05 grey - fine texture RAL 7047 light grey - satin

The manufacturer reserves the right to amend specifications without prior notice

Page 67


Sigma XT+

Extinguishant Coincidence Unit

Product Overview The Sigma XT+ ECD coincidence unit has two fully monitored inputs for connection to fire detection control equipment or addressable control modules to provide an EN12094-1 compliant extinguishant control system. Its many programmable features and extensive range of inputs and outputs make the Sigma XT+ ECD coincidence unit suitable for all extinguishing applications where a fully featured control device is required.

Features Complies with EN12094-1 Dual extinguishant outputs First and second stage sounder outputs

Among the many features of the Sigma XT+ ECD are serially connected status units for reduced wiring and reduced installation cost, dual extinguishant outputs that may be configured for main/reserve applications and a countdown timer which displays the time until discharge of the extinguishant in seconds. All units are independently configurable via a simple, code based programming interface to suit the desired application.

First and second stage relay contacts Main reserve facility Serial connection to status units Discharge countdown time indicator

Model No. K21001M2

Page 68


DS55.04.2011

Example Schematic 1 Sigma CP Ancillary Board (S580)

Sigma CP Sounder Board (S461)

24V Power Supply KENTEC ELECTRONICS LTD FUSE-T2A 250V HRC

Sigma CP-R Repeater Panel (Up to 7)

L E N LOAD 28V DC

1. MAINS FAILED 2. BATT. DISCONN. 3. BATTERY LOW 4. EARTH FAULT 5. CHARGER FAIL 6. COMMON FAULT L1 - MAINS FAIL L2 - BATT DISCON. L3 - BATTERY LOW L4 - EARTH FAULT L5 - CHGR. FAULT

REPLACE FUSE ONLY WITH 20mm TIME DELAY TYPE T2A250V

L2

L1

Specification

MODEL - ENS400 INPUT VOLTAGE - 230V AC INPUT CURRENT - 2A FREQUENCY - 50 - 60Hz OUTPUT VOLTAGE - 28V DC POWER RATING - 112W

24V BATT.

1. 2. 3. 4. 5. 6.

L1 L2

L5 L4 L3 L3

L4

L5

EN54-4 : 1998

Up to 4 Sigma XT+ coincidence units may be fitted Sigma XT+ Coincidence Unit

RS485

Sigma XT+ Coincidence Unit 230V

RS485

Sigma CP Control Panel

RS485

Up to 7 Ancillary Boards

K588 Ancillary Board

Up to 7 Ancillary Boards

K588 Ancillary Board

Up to 7 Status Units

System Status & Control

Up to 7 Status Units

System Status & Control

Example Schematic 2

1 Loop Module

Syncro Control Panel

Loop Module Sigma XT+ Coincidence Unit

Sigma XT+ Coincidence Unit 230V

RS485

RS485

Up to 7 Ancillary Boards

K588 Ancillary Board

Up to 7 Ancillary Boards

K588 Ancillary Board

Up to 7 Status Units

System Status & Control

Up to 7 Status Units

System Status & Control

Technical Product Code Size Construction Finish Colour - lid & box Colour - controls plate & labels Areas Mains supply Mains supply fuse Power supply rating

-

- 1 - 230V AC, 50Hz +10% - 15% (100 Watts max.) - 1.6 Amp ( F1.6A L250V) - 5.25 Amps total including battery charge 28V +/- 2V - 200 millivolts - 12 Volt sealed lead acid in series - Yuasa 2.3Ah

Maximum ripple current Battery type (Yuasa NP) Maximum Battery Capacity within Enclosure Battery charge voltage Battery charge current Battery fuse Current draw in mains fail condition Maximum current draw from batteries Aux 24V output 1st and 2nd stage Sounder outputs Fault relay contact rating Fire relay contact rating

K21001M2 385mm(W) x 310mm(H) x 90mm(D) 1.2mm mild sheet steel Epoxy powder coated BS 00 A 05 grey - fine texture RAL 7047 light grey - satin

27.6VDC nominal (temperature compensated) 0.7A maximum 20mm, 3.15A glass 54 milliamps 4 Amps

Fused at 500mA with electronic fuse 21 to 28V DC Fused at 1A with electronic fuse 5 to 30VDC 1A Amp maximum for each - 5 to 30VDC 1A Amp maximum for each

Local fire relay contact rating First stage contact rating

- 5 to 30VDC 1A Amp maximum for each - 5 to 30VDC 1A Amp maximum for each Second stage contact rating - 5 to 30VDC 1A Amp maximum for each Extract contact rating - 5 to 30VDC 1A Amp maximum for each Zone quiescent current - 0mA minimum, 2mA maximum Terminal capacity - 0.5mm2 to 2.5mm2 solid or stranded wire Number of sounders - Dependent on type and per circuit current consumption Monitored input end of line - 6K8 +/- 5% ½ Watt resistor Sounder circuit end of line 10K +/- 5% ¼ Watt resistor Extinguishant output - 1N4004 Diode end of line Extinguishant release output - 21 to 28V DC. Fused at 1 Amp Extinguishant release delay Adjustable 0 to 60 seconds - (+/- 10%) Extinguishant release - Adjustable 60 to 300 seconds duration Monitored inputs normal - (Allowable EOL) threshold 10K ohm to 2K ohm Monitored inputs alarm - 2K ohms to 150 ohms +/- 5% threshold Monitored inputs Short - 140 ohms to 0 ohms +/- 5% circuit threshold Status unit/Ancillary - Two wire RS485 connection board connection (EIA-485 specification) Status unit power output - 21 to 28V DC, Fused at 500mA with electronic fuse The manufacturer reserves the right to amend specifications without prior notice

Page 69


Sigma Si

& Hold Switch Extinguishant Status Indicators

Sigma Si

Product Overview The Sigma Si range of status indicators provide detailed status information for Sigma XT/XT+ extinguishant release control equipment. All models provide high brightness, LED indication of Manual Only, Automatic and Manual, Hold operated, Disabled, Imminent and Released conditions. Models are also available with zonal fire indicators and a common fault indicator. For systems where local control of the Automatic/Manual mode and or a Manual extinguishant release control are required, units are available with these controls fitted.

Sigma Si

Features

All models have monitored inputs for the remote connection of Automatic/ Manual mode and Hold switches.

Certified compliant with BS EN12094-1 when used with Sigma XT control equipment

All units contain a large, LED display which shows a countdown of the time remaining until the extinguishant is released in seconds.

High brightness LEDs Detailed indication of the status of the control panel Monitored data connection

Hold off

Countdown timer shows time remaining until release

Product Overview

Manual only and Automatic & Manual mode select keyswitch option

Available with red or green actuators (BS 7273-1 recommends white with red button)

Four wire connection (data and power)

Shrouded push button to prevent accidental operation

Protected dual action manual release switch option

Fitted with normally open and normally closed contacts to allow operation with monitored and unmonitored systems

Option for zonal fire and common fault indication with buzzer

Robust all steel enclosure

Robust, high quality enclosure Easy access to terminals Remote Auto/Manual door interlock input (monitored) Remote Hold input (monitored) Internal fault diagnosis indicators Weatherproof IP65 versions available Internal buzzer

Model No. K91000M10

Model No. K911000M8

Page 70

Model No. K911111M8

Model No. K911113M8

Model No. K911100M8

Model No. K911110M8


DS41.04.2011

Manual Only Auto/Manual

Specification

Hold Activated Disabled

256mm

Imminent Released

available on 10 lamp units only

Fire Zone 2 Fire Zone 3

170mm

Fire Zone 1

Fault Weatherproof Version Model No. W911113W8*

Equipment Product Code Description

Size (mm)

K911000M8 K911000F8 K911100M8 K911100F8 K911010M8 K911010F8 K911110M8 K911110F8 K911113M8* K911113F8*

6 lamp status unit surface 6 lamp status unit flush 6 lamp status unit with mode select keyswitch surface 6 lamp status unit with mode select keyswitch flush 6 lamp status unit with manual release surface 6 lamp status unit with manual release flush 6 lamp status unit with mode select keyswitch and manual release surface 6 lamp status unit with mode select keyswitch and manual release flush 10 lamp status unit with mode select keyswitch and manual release surface 10 lamp status unit with mode select keyswitch and manual release flush

186 x 132 x 50 186 x 132 x 55 186 x 132 x 50 186 x 132 x 55 186 x 132 x 50 186 x 132 x 55 186 x 132 x 50 186 x 132 x 55 186 x 132 x 50 186 x 132 x 55

W911000W8 W911100W8 W911110W8 W911113W8*

IP65 - 6 lamp status unit surface IP65 - 6 lamp status unit with mode select keyswitch surface IP65 - 6 lamp status unit with mode select keyswitch and manual release surface IP65 - 10 lamp status unit with mode select keyswitch and manual release surface

256 x 170 x 60 256 x 170 x 60 256 x 170 x 60 256 x 170 x 60

K91000M10 KB91000M10

Extinguishant hold off switch unit - green button Extinguishant hold off switch unit - red button

97 x 97 x 45 97 x 97 x 45

* Not suitable for Sigma XT+ / Syncro XT+ or Sigma XT+ ECU products

Sigma Si

Hold off

Technical Construction Colour - lid & box Power supply Maximum current draw Max. number of status units Quiescent current Cable capacity Monitored inputs end of line resistor Monitored inputs normal threshold Monitored inputs trigger threshold Monitored inputs Short circuit threshold Data connection

Technical -

1.2mm mild sheet steel BS 00 A 05 grey - fine texture

21 to 30 V DC 0.07A 7 0.033A 2.5mm² per terminal 6K8 0.5W Resistor

Construction Colour - lid & box Contacts Trigger resistor

-

1.2mm mild sheet steel White 1 N.O and 1 N.C 470R 1 Watt

8K ohm to 1K ohm 700 ohms to 100 ohms 99 ohms to 0 ohms Two wire RS485 connection (max 1200 metres)

The manufacturer reserves the right to amend specifications without prior notice

Page 71


Sigma Si

Ancillary PCB Extinguishant Ancillary PCB Ancillary PCB

Product Overview The Sigma XT Ancillary Board is compatible with all Sigma XT control panels which have operating software version SIGXT_11A.HEX or above. The board provides volt free normally open contacts allowing control of sub-systems and plant remotely from the main panel over a two wire data bus. Mains powered, boxed Ancillary boards require only a two core data cable from the main control panel. 24V DC versions require an additional two cores for power either from the main panel or from another 24V DC source.

Ancillary PCB

Features

Up to 7 Ancillary boards can be connected to a control panel and each is allocated an address from 1 to 7 using a binary coded DIL switch. The total length of the data cable from the main panel to the last repeater must not exceed 1200 metres.

Two wire serial connection Up to 7 per system

A mixture of status units and Ancillary boards, up to a maximum of 7 of each type, can be connected to the serial data bus.

230V AC or 24V DC powered versions Volt free relay outputs for fire and extinguishing system status Relay operated LED indicators

HOLD MODE OUT IN RS485 24V DC

Status PCB

Equipment

6K8 6K8

470R

Product Code Description

Size (mm)

K588 K03000M2 K03750M2

155 x 136 385 x 310 x 90 385 x 310 x 90

Stand alone ancillary PCB Boxed ancillary PCB Boxed ancillary PCB with 0.75A PSU

470R

To next Status Unit if fitted From previous status unit or control panel To next Status Unit if fitted From previous status unit or control panel

Ancillary PCB

Technical Construction (Boxed) Colour - lid & box

- 1.2mm mild sheet steel - BS 00 A 05 grey - fine texture Supply voltage (K03750M2) - 230V AC (+10%/-15%) Supply voltage (K03000M2) - 20-30V DC

Mains supply fuse Power supply DC rating Maximum battery size Contact ratings Cable capacity Operating temperature Operating humidity

Model No. K1822

Page 72

-

1.6A 250V 24V 0.75 Amp 2Ah 24V (2 per panel) 30V DC 1 Amp 2.5mm² per terminal -5°C to +50°C <95% (non condensing)


DS75.01.2011

Specification + - +-

+ - + 24V DC

24V DC

Z1

Z2

PF

Z1 FIRE

Z3

Z2 FIRE

Z3 MAN DISAB FIRE MODE

MAN DISAB

REL

ACT

REL

MAN REL

ACT

EXTR

HOLD EXTR

HOLD

MAN RS485 RS485 REL OUT IN

FUSE OK FAIL

PROCESSOR RESET

ADDRESS

Door Interlock

Hold 1st Stage Sounders

Low Pressure Switch Released Pressure Switch Activate Extinguisher

2nd Stage Sounders

Detection Zone 3

Manual Release

Example System Schematic

Detection Zone 2 Detection Zone 1

System Status and Control 4 Core

Ancillary Board EN12094-1 Approved Control Unit

System Status and Control

Addressable House Fire Alarm

System Status and Control

BMS Interface

4 Core

Ancillary Board

The manufacturer reserves the right to amend specifications without prior notice

Page 73


XT+

Multi-Area, Addressable Extinguishant Control Panels

CO SO MI O NG N

Syncro

Product Overview Syncro XT+ control panels are multi-area extinguishant control panels complying with EN12094-1. p to 16 zones of addressable detection over 1 or 2 loops ensure U every detector is able to contribute to extinguishant release. Up to 4 extinguishant areas are available. Stand alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules.

Features Complies with EN12094-1 16 detection zones

Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface. All extinguishant areas may have up to 7, serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. For compatible status units see Sigma Si data sheet DS41 (page 70-71).

Up to 4 extinguishant areas Dual extinguishant outputs for each area (configurable as Main/Reserve) First and second stage sounder outputs for each area First and second stage volt free changeover contacts for each area Released volt free contact per area Fault volt free contact per area Programmable extinguishant delays Programmable output duration Countdown indicator shows time until release in seconds Mode select and manual release controls per area Monitored remote manual release input Monitored remote hold input Monitored remote mode select (door interlock) input Monitored remote released pressure switch input Monitored Abort input Serial connections for Sigma Si status units and ancillary boards. (K588)

Model No. #32162M3

Page 74


DS58.02.2011

Specification Panels Product Code Loop Areas Size (mm) #31161M3 #32161M3 #31162M3 #32162M3 #31163M4 #32163M4 #31164M4 #32164M4

1 2 1 2 1 2 1 2

1 1 2 2 3 3 4 4

385 x 520 x 110 385 x 520 x 110 385 x 520 x 110 385 x 520 x 110 385 x 700 x 145 385 x 700 x 145 385 x 700 x 145 385 x 700 x 145

‘#’ - replace with: ‘A’ for Apollo protocol, ‘H’ for Hochiki protocol ‘V’ for Argus Vega protocol

Technical Construction Finish Colour - lid & box Colour - controls plate & labels Mains supply Mains supply fuse Power supply rating (1 & 2 area units) Power supply rating (3 & 4 area units) Maximum ripple current Battery charge voltage Battery charge current Battery fuse Current draw in mains fail condition Max. current draw from batteries

-

Sigma XT+ module Aux 24V output Syncro AS Aux 24V output 1st and 2nd stage Sounder outputs Fault relay contact rating Fire relay contact rating Local fire relay contact rating First stage contact rating Second stage contact rating Extract contact rating Terminal capacity Number of sounders per circuit Monitored input end of line Sounder circuit end of line Extinguishant output end of line Number of detection loops Number of zones No. of sounder circuits Extinguishant release output Extinguishant release delay Extinguishant release duration SIL, AL, FLT, RST inputs Cabling Monitored inputs normal threshold Monitored inputs alarm threshold Monitored inputs Short circuit threshold Status unit/Ancillary board connection Status unit power output

-

1.2mm mild sheet steel Epoxy powder coated BS 00 A 05 grey - fine texture RAL 7047 light grey - satin

230V AC, 50Hz +10% - 15% (100 Watts maximum) 1.6 Amp ( F1.6A L250V) 3 Amps total including battery charge 28V +/- 2V 4 Amps including battery charge 28V +/- 2V 200 millivolts 27.6VDC nominal (temperature compensated) 0.7A maximum 20mm, 3.15A glass 54 milliamps per extinguishing module 3A (#31161M3, #32161M3, #31162M3, #32162M3) 5.25A (#31163M4, #32163M4, #31164M4, #32164M4) Fused at 500mA with electronic fuse - 1 per extinguishant area Fused at 2.5A - not available to user 21 to 28V DC Fused at 1A with electronic fuse 5 to 30VDC 1A Amp maximum for each 5 to 30VDC 1A Amp maximum for each 5 to 30VDC 1A Amp maximum for each 5 to 30VDC 1A Amp maximum for each 5 to 30VDC 1A Amp maximum for each 5 to 30VDC 1A Amp maximum for each 0.5mm2 to 2.5mm2 solid or stranded wire Dependent on type and current consumption - typically 20+ 6K8 +/- 5% ½ Watt resistor 10K +/- 5% ¼ Watt resistor 1N4004 Diode 1 or 2 16 Dependent on model 21 to 28V DC 21 to 28V DC. Fused at 1 Amp Adjustable 0 to 60 seconds (+/- 10%) Adjustable 60 to 300 seconds Switched -ve, min resistance 0 ohms, max resistance 100 Ohms FP200 or equivalent (max capacitance 1uF max inductance 1 mH 10K ohm to 2K ohm 2K ohms to 150 ohms +/- 5% 140 ohms to 0 ohms +/- 5% Two wire RS485 connection (EIA-485 specification) 21 to 28V DC. Fused at 500mA with electronic fuse The manufacturer reserves the right to amend specifications without prior notice

Page 75


A-XT

Extinguishant Control Panel

! N EW

Sigma

Product Overview Designed and manufactured to the highest standards in a quality controlled environment and with UL and FM approvals, the Sigma A-XT releasing panel offers outstanding value and performance for all small to medium fixed firefighting installations.

Features UL864 and FM listed Three initiation circuits as standard Any single zone or any combinations of zones can be configured to release Configurable first stage NAC delays Configurable detection delays Zero time delay upon manual release option Compatible with I.S. barriers Non-latching zone input option to receive signals from other systems such as aspirating equipment Configurable releasing delays up to 60 seconds in 5 second steps Configurable releasing duration up to 5 minutes in 5 second steps

With three initiation circuits as standard, release can be configured to activate from any combination of detection zone inputs to allow (among other combinations) any two from three type activations such as would be required for detection in ceiling void, room and floor void applications. The extensive configuration options of the Sigma A-XT allow the functionality of the system to be extensively modified. The panel contains a large LED display to enable easy configuration and control which also displays the time remaining until release for added user safety. The countdown timer is duplicated on up to seven remote status units to provide local indication of the system status. With all of the electronics mounted on a single, easily removable, steel plate Sigma A-XT panels are both robust and easy to install. Sigma A-XT is supplied in an enclosure that matches the design and color of the Elite RS range and is available in standard red or optional gray.

Countdown timer shows time remaining until release Supports up to seven, four wire status indicators Built in Extract Fan control

Programmable Functions Access Level 2

Test Zones 1 to 3 Disable Zones 1 to 3 Disable 1st Stage Alarms Disable Pre-activated 1st Stage Relay Disable Pre-activated 2nd Stage Relay Disable Extract Fan Output Disable Manual Release Input Disable Releasing Sub System Activate Extract Fan Output Activate Alarm Delays

Access Level 3

Page 76

Sounder Delay Coincidence Detection Disable Panel Features Zone Alarm Delays (Detectors) Zone Alarm Delay (Call stations) Configure Zone for I.S Barrier Use Zone Short Circuit Alarm Zone Non Latching Zone Inputs Delay Extinguishant Release Time Delay Extinguishant Release Duration Timer Extinguishant Reset Delay Timer

Model No. K1810-10


DS72.01.2011

Technical Construction Finish Colour - lid & box Mains supply Mains supply fuse Power supply rating Maximum ripple current Battery type (Yuasa NP) Battery charge voltage Battery charge current Battery fuse Maximum current draw from batteries Quiescent current of panel in mains fail R0V output Sounder outputs Fault relay contact rating Fire relay contact rating Local fire relay contact rating First stage contact rating Second stage contact rating Extract contact rating Zone quiescent current Terminal capacity Number of detectors per zone NAC rating Detection circuit end of line Monitored input end of line Sounder circuit end of line Extinguishant output EOL No. of initiating circuits No. of NAC circuits Extinguishant release output Extinguishant release delay Extinguishant release duration SIL, AL, FLT, RST inputs Zone normal threshold Detector alarm threshold Call point alarm threshold Short circuit threshold Monitored inputs normal threshold Monitored inputs alarm threshold Monitored inputs Short circuit threshold Status unit/Ancillary board connection Status unit power output

-

1.2mm mild sheet steel Epoxy powder coated Red (optional grey) 230V AC or 115V AC 1.6 Amp (F1.6A L250V) 3 Amps total including battery charge 28V +/- 2V 200 millivolts Two 12 Volt 7Ah sealed lead acid in series 27.6VDC nominal (temperature compensated) 0.7A maximum 20mm, 3.15A glass 3 Amps 0.095A Fused at 500mA with electronic fuse 24V Fused at 500mA with electronic fuse 30VDC 1A Amp maximum 30VDC 1A Amp maximum 30VDC 1A Amp maximum 30VDC 1A Amp maximum 30VDC 1A Amp maximum 30VDC 1A Amp maximum 2mA maximum

Specification

12 AWG

Dependent on type (maximum 32) 0.5A per circuit 6K8 5% ½ Watt resistor 6K8 5% ½ Watt resistor 10K 5% ¼ Watt resistor 1N4004 Diode 3 2 x 1st Stage, 1 x 2nd Stage Fused at 1 Amp Adjustable 0 to 60 seconds (in 5 second steps) Adjustable 60 to 300 seconds (in 5 second steps) Switched -ve, max resistance 100 Ohms 8K ohms to 1K ohm 999 ohms to 400 ohms 399 ohms to 100 ohms 99 ohms to 0 ohms 8K ohms to 1K ohm 999 ohms to 100 ohms 99 ohms to 0 ohms Two wire RS485 connection Fused at 500mA with electronic fuse

Panels Product Code

K1810-12 K1810-13 K1810-44 K1810-43

Description

Size (mm)

Surface mounting panel - Red 115V Surface mounting panel - Red 230V Surface mounting panel - Grey 115V Surface mounting panel - Grey 203V

368 x 310 x 90 368 x 310 x 90 368 x 310 x 90 368 x 310 x 90

The manufacturer reserves the right to amend specifications without prior notice

Page 77


A-Si

! N EW

Sigma

& Abort Switch Extinguishant Status Indicators

Sigma A-Si

Product Overview The Sigma A-Si range of status indicators provide detailed status information for Sigma A-XT releasing control equipment. All models provide high brightness, LED indication of Manual Only, Automatic and Manual, Abort operated, Disabled, Imminent and Released conditions. Models are also available with zonal fire indicators and a common trouble indicator. For systems where local control of the Automatic/Manual mode and or a Manual extinguishant release control are required, units are available with these controls fitted.

Sigma A-Si

Features

All models have supervised inputs for the remote connection of Automatic/ Manual mode and abort switches.

UL864 and FM listed

All units contain a large, LED display which shows a countdown of the time remaining until release in seconds.

High brightness LEDs Detailed indication of the status of the control panel Supervised data connection

Abort Switch

Countdown timer shows time remaining until release

Product Overview

Manual only and Automatic & Manual mode select keyswitch option

The Sigma A-XT Abort switch connects to the Abort terminals of the Sigma A-XT releasing panel. Any number of Sigma A-XT Abort switches may be connected to the circuit.

Four wire connection (data and power) Protected dual action manual release switch option

The last switch must have the end of line device from the Abort circuit terminals of the Sigma A-XT releasing panel fitted across its connections to provide open and short circuit supervision.

Option for zonal fire and trouble indication with buzzer

The unit is supplied mounted to a rugged steel enclosure but may also be flush mounted to a single gang electrical box.

Robust, high quality enclosure Easy access to terminals Remote Auto/Manual door interlock input (supervised) Remote Abort input (supervised) Internal trouble diagnosis indicators

Model No. K1821-19 Model No. K1823-10

Model No. K1821-11

Page 78

Model No. K1821-15

Model No. K1821-13

Model No. K1821-17


DS73.01.2011

Manual Only Auto/Manual

Specification

Abort Activated Disabled Imminent Released Fire Zone 1 Fire Zone 2 Fire Zone 3 Trouble

Equipment Product Code Description

Size (mm)

K1821-11 K1821-41 K1821-12 K1821-42 K1821-13 K1821-43 K1821-14 K1821-44 K1821-15* K1821-45* K1821-16* K1821-46* K1821-17* K1821-47* K1821-18* K1821-48* K1821-19* K1821-49* K1821-20* K1821-50* K1823-10 K1823-40

186 x 132 x 50 186 x 132 x 50 186 x 132 x 55 186 x 132 x 55 186 x 132 x 50 186 x 132 x 50 186 x 132 x 55 186 x 132 x 55 186 x 132 x 50 186 x 132 x 50 186 x 132 x 55 186 x 132 x 55 186 x 132 x 50 186 x 132 x 50 186 x 132 x 55 186 x 132 x 55 186 x 132 x 50 186 x 132 x 50 186 x 132 x 55 186 x 132 x 55 98 x 98 x 59 98 x 98 x 59

6 lamp status unit surface mount - red 6 lamp status unit surface mount - gray 6 lamp status unit flush mount - red 6 lamp status unit flush mount - gray 6 lamp status unit with mode select keyswitch surface mount - red 6 lamp status unit with mode select keyswitch surface mount - gray 6 lamp status unit with mode select keyswitch flush mount - red 6 lamp status unit with mode select keyswitch flush mount - gray 6 lamp status unit with manual release surface mount - red 6 lamp status unit with manual release surface mount - gray 6 lamp status unit with manual release flush mount - red 6 lamp status unit with manual release flush mount - gray 6 lamp status unit with mode select keyswitch & manual release surface mount - red 6 lamp status unit with mode select keyswitch & manual release surface mount - gray 6 lamp status unit with mode select keyswitch & manual release flush mount - red 6 lamp status unit with mode select keyswitch & manual release flush mount - gray 10 lamp status unit with mode select keyswitch & manual release surface mount - red 10 lamp status unit with mode select keyswitch & manual release surface mount - gray 10 lamp status unit with mode select keyswitch & manual release flush mount - red 10 lamp status unit with mode select keyswitch & manual release flush mount - gray Elite Extinguishing Abort switch surface mount - red Elite Extinguishing Abort switch surface mount - gray

* Not UL/FM Listed

Sigma A-Si

Abort Switch

Technical Construction Colour - lid & box Power supply Maximum current draw Max. number of status units Quiescent current Cable capacity Monitored inputs end of line resistor Monitored inputs normal threshold Monitored inputs trigger threshold Monitored inputs Short circuit threshold Data connection

Technical -

1.2mm mild sheet steel Red (optional grey)

21 to 30 V DC 0.07A 7 0.033A 2.5mm² per terminal 6K8 0.5W Resistor

Construction Colour Switch rating Trigger resist End of line resistor

-

1.2mm mild sheet steel Red (optional grey)

1A at 30V DC 470R 1W 6K8 1/2 W

- 8K ohm to 1K ohm - 700 ohms to 100 ohms - 99 ohms to 0 ohms - Two wire RS485 connection

(max 1200 metres)

The manufacturer reserves the right to amend specifications without prior notice

Page 79


A-XT

Ancillary PCB

N EW

!

Sigma Extinguishant Ancillary PCB Ancillary PCB

Product Overview The Sigma A-XT Ancillary Board is compatible with all Sigma A-XT control panels. The board provides volt free normally open contacts allowing control of sub-systems and plant remotely from the main panel over a two wire data bus. Ancillary boards require only a two core data cable from the main control panel and a two core power cable from the main panel.

Ancillary PCB

Up to 7 Ancillary boards can be connected to a control panel and each is allocated an address from 1 to 7 using a binary coded DIL switch. The total length of the data cable from the main panel to the last repeater must not exceed 4000 feet.

UL864 and FM listed

A mixture of status units and Ancillary boards, up to a maximum of 7 of each type, can be connected to the serial data bus.

Features

Two wire serial connection Up to 7 per system Volt free relay outputs for fire and releasing system status

Equipment

Relay operated LED indicators

ABORT MODE OUT IN RS485 24V DC

Status PCB

6K8 6K8

470R

Product Code Description

Size (mm)

K1822-00 K1822-10

155 x 136 385 x 310 x 90 385 x 310 x 90

K1822-40

Sigma A-XT Ancillary Board Sigma A-XT Ancillary Board with cabinet - red Sigma A-XT Ancillary Board with cabinet - gray

470R

To next Status Unit if fitted From previous status unit or control panel To next Status Unit if fitted From previous status unit or control panel

Ancillary PCB

Technical Construction (Boxed) Colour - lid & box Supply voltage Contact ratings Cable capacity Operating temperature Operating humidity

Model No. K1822

Page 80

-

1.2mm mild sheet steel Red (optional grey)

20-30V DC 30V DC 1 Amp 2.5mm² per terminal -5°C to +50°C <95% (non condensing)


DS74.01.2011

Specification + - + 24V DC

24V DC

Z1

Z2

PF

Z1 FIRE

Z3

Z2 FIRE

Z3 MAN DISAB FIRE MODE

MAN DISAB

REL

ACT

REL

MAN REL

ACT

EXTR

HOLD EXTR

HOLD

+ - +-

MAN RS485 RS485 REL OUT IN

FUSE OK FAIL

PROCESSOR RESET

ADDRESS

Door Interlock

Hold 1st Stage Sounders

Low Pressure Switch Released Pressure Switch Activate Extinguisher

2nd Stage Sounders

Detection Zone 3

Manual Release

Example System Schematic

Detection Zone 2 Detection Zone 1

System Status and Control 4 Core

Ancillary Board Sigma A-XT Control Panel

System Status and Control

Addressable House Fire Alarm

System Status and Control

BMS Interface

4 Core

Ancillary Board

The manufacturer reserves the right to amend specifications without prior notice

Page 81


Power Supplies

Pages 84-88


PSU EN54-4 Approved Fire Alarm Power Supplies Page 84-85 PSU EN54-4 Approved Switched Mode Power Supply / Charger Page 86-87 PSU EN54-4 Compliant 10.25 Amp Power Supply Page 88

COMING SOON


PSU BS-EN54-4 KM 73505

EN54-4 Approved Fire Alarm Power Supplies

Product Overview Syncro Power fully certified to EN54-4 power supplies provide a stable and fully regulated, true 24V output for fire alarm system applications under all power conditions. The unique regulation techniques ensure that even when running on standby batteries, a stable 24V supply is available to all parts of the system ensuring that all 24V powered devices connected are supplied with optimum power. The powerful onboard micocontroller ensures that all battery types are conditioned with optimum, temperature compensated charging algorythms to maximise battery life and maintain batteries in top condition.

Features 2.5A and 5.25A versions Chassis only or enclosure mounted with battery space 110V or 230V input Regulated, true 24V output Intelligent battery charging and temperature compensation House up to 26Ah batteries Status indicators for monitored faults

Syncro Power EN54-4 compliant power supplies can be fitted with an optional dual fused output monitoring module to ensure compliance with European standards when supplying fire control panels with an external power supply. Enclosed units are available to match both Sigma and Syncro equipment ranges and all are finished with matching livery and provide power on and power fault indications. Optional dual output path (KD) variant available, to provide two independent supply paths between the power supply unit and the control panel in accordance with EN54-4 clause 6.4 and BS5839 pt1, clause 12.2.2.m requirements.

Dual output option for powering fire alarm control panels remotely Chassis versions have same mounting points Fully enclosed and robust construction

Boxed Power Supply to match Sigma CP and Syncro AS Style

Page 84

Boxed Power Supply to match Syncro Style


DS61.04.2011

Specification

Panels Product Code

PSU

Batteries Size (mm)

K25250M2 K25250M3 K2525003 K25400M3 K2540003 K2540015

2.5 Amp up to 7Ah 2.5 Amp up to 12Ah 2.5 Amp up to 12Ah 5.25 Amp up to 17.2Ah 5.25 Amp up to 12Ah 5.25 Amp up to 26Ah

365 x 310 x 90 385 x 520 x 110 500 x 355 x 117 385 x 520 x 110 500 x 355 x 117 500 x 460 x 190

KD25250M2 KD25250M3 KD2525003 KD25400M3 KD2540003 KD2540015

2.5 Amp up to 7Ah 2.5 Amp up to 12Ah 2.5 Amp up to 12Ah 5.25 Amp up to 17.2Ah 5.25 Amp up to 12Ah 5.25 Amp up to 26Ah

365 x 310 x 90 385 x 520 x 110 500 x 355 x 117 385 x 520 x 110 500 x 355 x 117 500 x 460 x 117

With Dual Output Board With Dual Output Board With Dual Output Board With Dual Output Board With Dual Output Board With Dual Output Board

Technical Construction Finish colour - lid & box Mains input supply voltage Mains supply fuse Load output voltage Maximum load current – K25400 models Maximum load current – K25250 models Maximum ripple Load fuse Maximum current draw from batteries Battery charge output voltage

-

Battery charge current Deep discharge prevention Compatible batteries

- Two stage, constant voltage. 1.25 Amps maximum - Battery disconnects at 19V - Yuasa – NP7-12, NP12-12, NP17-12, NP24-12

Operating temperature Common fault output Battery disconnected output Battery low output Charger fault output Earth fault output Mains failed output Fault output connector Mains connector Load connector Battery connector Front panel Power On indicator Front panel Fault indicator Power output

-

1.2 mild sheet steel Epoxy powder coated BS 00 A 05 grey - fine texture

230V AC 50/60Hz or 110V AC 50/60Hz (link selectable) 250V, 3A, SB, 5mm X 20mm 19- 30V DC +/- 1% 5.25 Amps continuous with maximum battery charge output of 1.25A - 2.5 Amps continuous with maximum battery charge output of 1.0A - 200 milliamps - 5 Amp, self resetting Polyfuse - 5 Amps - 27.4V DC nominal at 20 degrees C

(temperature compensated from -5 to 45 degrees C

Powersonic – PS-1270, PS-12120, PS-12170, PS12260 -5 to 45 degrees C Normally energised volt free changeover relay – 30V DC 1 Amp Open collector 50 milliamps Open collector 50 milliamps Open collector 50 milliamps Open collector 50 milliamps Open collector 50 milliamps 14 way DIL header 0.1” spacing 3 way terminal, 7.62mm spacing, 2.5mm maximum cable size 2 way terminal, 7.62mm spacing, 2.5mm maximum cable size 2 way terminal, 7.62mm spacing, 2.5mm maximum cable size Green LED Yellow LED Dual 24V supply terminals with EN54-4 clause 6.4 interface (when fitted with optional dual fused output monitoring module)

The manufacturer reserves the right to amend specifications without prior notice

Page 85


PSU BS-EN54-4 KM 73505

EN54-4 Approved Switched Mode Power Supply/Charger

Product Overview The S407/S406 power supply/battery charger has been developed using switched mode technology to produce an efficient and lightweight power unit for a host of fire alarm applications.

S407

Features Complies with EN54-4 Fully enclosed construction Small & lightweight True 2.5 Amp continuous output

Suited to almost any application, the S407/S406 is designed to be a universal power source which will reduce spares stock holding and increase serviceability of systems. The comprehensive monitoring features of the S407/S406 include true battery present detection, low battery voltage warning, battery overcharge warning, high battery impedance monitoring and low battery shut off. These features combined with the temperature compensated charger output will increase the service life of sealed lead acid batteries.

Comprehensive fault monitoring Temperature compensated charger Wide input supply voltage Low battery shut off to prevent deep discharge of battery

S406

Features Complies with EN54-4 Fully enclosed construction Small & lightweight True 5.25 Amp continuous output

S407 - 2.5 Amp PSU

Comprehensive fault monitoring Microprocessor controlled Temperature compensated charger Wide input supply voltage Low battery shut off to prevent deep discharge of battery

S406 - 5.25 Amp PSU

Page 86


DS19.09.2011

Formula Battery Calculation BS 5839-1:2002 C min = 1.25 (T1 I1 + D I2 /2)

Specification

Where: C min = Minimum capacity of the battery when new at the 20 hour discharge rate and at 20 째C in ampere-hours; T1 = Total battery stand by period in hours; I1 = Total battery stand by load in amperes; I2 = Total battery alarm load in amperes; D = a de-rating factor. (1.75)

S407

Technical Construction Finish Colour Size Weight Supply voltage Output voltage Total output current Battery charge current Load current Fault outputs rating Mains fuse Load fuses Mains failed warning Battery disconnected warning Battery low warning Battery overcharge warning Earth fault warning Common fault output Operating temperature

-

Aluminium base - sheet steel cover Epoxy powder coated Black 226mm x 120mm x 55mm 0.9Kg 230V AC (+10%/-15%) 27.5V DC (temperature compensated) 3.5 Amps (continuous) 1.25 Amps max. 2.5 Amps (with flat battery) 50mA max. 3 Amp 20mm HRC 3 Amp (self resetting) Switched -ve output Switched -ve output Switched -ve output Switched -ve output Switched -ve output Switched -ve output -5 to +50 deg. C

-

Aluminium base - sheet steel cover Epoxy powder coated Black 226mm x 120mm x 55mm 0.9Kg 230V AC (+10%/-15%) 27.5V DC (temperature compensated) 5.25 Amps (continuous) 1.25 Amps max. 4.0 Amps (with flat battery) 50mA max. 3 Amp 20mm HRC 5 Amp (self resetting) Switched -ve output Switched -ve output Switched -ve output Switched -ve output Switched -ve output Switched -ve output -5 to +50 deg. C

S406

Technical Construction Finish Colour Size Weight Supply voltage Output voltage Total output current Battery charge current Load current Fault outputs rating Mains fuse Load fuses Mains failed warning Battery disconnected warning Battery low warning Battery overcharge warning Earth fault warning Common fault output Operating temperature

The manufacturer reserves the right to amend specifications without prior notice

Page 87


PSU

EN54-4 Compliant 10.25 Amp Power Supply

CO SO MI O NG N

DS67.02.2011

Product Overview The S408 is an EN54-4 compliant, universal input switching power supply capable of delivering a full 290W of continuous power for fire alarm systems. Suitable for charging a range of sealed lead acid batteries from 7Ah to 45Ah, the S408 power supply features complete monitoring of primary and secondary power sources with fully temperature compensated battery charging and battery high impedance monitoring.

Features Continuous 8A load output while charging fully depleted batteries

The S408 power supplies are available as chassis only units or mounted in a range of enclosures suitable for various sizes of battery.

Charges up to 45Ah batteries

Panels

Complies with EN54-4 94V to 253V AC input

Product Code

Batteries Size (mm)

S408 (Chassis only) K25800M3 K2580003 K2580015 K25800D3

N/A Up to 17Ah Up to 17Ah Up to 45Ah Up to 45Ah

120 x 260 x 65 385 x 520 x 110 500 x 355 x 117 500 x 460 x 190 385 x 520 x 200

Low battery cut out

KD25800M3* KD2580003* KD2580015* KD25800D3*

Up to 17Ah Up to 17Ah Up to 45Ah Up to 45Ah

385 x 520 x 110 500 x 355 x 117 500 x 460 x 190 385 x 520 x 200

Temperature compensated battery charging

*With Dual Output Board

Mains fail monitoring with LED indication and output Battery disconnection monitoring with LED indication and output Low battery monitoring with LED indication and output Earth fault monitoring with LED indication and output

Lightweight construction

Technical Construction Finish Colour

- 1.2mm mild sheet steel - Epoxy powder coated - BS 00 A 05 grey -

Input voltage Output voltage Total output current Battery charge current Load current Fault outputs rating Mains fuse Load fuses Mains failed warning Battery disconnected warning Battery low warning Battery overcharge warning Earth fault warning Common fault output Operating temperature

-

fine texture 94 to 253V AC 50/60 Hz 24V DC 10.25A 2.25A 8.0A (with flat battery) 50mA max. 5A 20mm HRC 10A (self resetting) Switched -ve output Switched -ve output

- Switched -ve output -

Switched -ve output

- Switched -ve output - Switched -ve output - -5 to +50 deg. C Boxed Power Supply to match Syncro Style

Page 88


Power, Intelligence...... with a sense of feeling

A new era in life safety alarm management All New Control Systems Innovative Annunciator ranges Market leading data storage and access facilities Unique system management tools

Come and join us on our Journey


Miscellaneous Items Pages 92-101


Sigma DocBox Document Enclosure Page 92

Vision Window Tamper Resistant Vision Window Page 93

Warning Signs NEW! Illuminated signs using high intensity LED indicators Page 94-95 NEW! Remote Indicator Remote Fire Detector Indicator Units Page 96-97 NEW! Audio Visual Audible and Visual Indicator Units Page 98

Relay Boards Single (RL1) and Four (RL4) Way Relay PCB Page 99 Hydrosense Water Detection System Page 100-101


DS42.04.2011

Sigma

DocBox

Sigma Doc Box Product Overview Another addition to the Kentec range, the document box is designed to complement the design & colour of the Sigma CP range of control panels. The standard version Document Box will hold up to 50 A4 sheets of information on the Fire Detection or other security systems within a premises. The deep version will hold up to 100 sheets. The “Doc Box� also doubles up as a Key Box providing 7 easily accessible formed key hooks inside the enclosure.

Features Matches design & colour scheme for standard Sigma CP/XT & Syncro AS control panel ranges Easy to install Key Lockable Designed for versatility Choice of small or large capacity enclosure

Technical Part Number Size

- K16000L2 (Standard version) - 385mm(W) x 310mm(H) x

Part Number Size

- K16000M2 (Deep version) - 385mm(W) x 310mm(H) x

Construction Finish Colour - lid & box Weight

- 1.2mm mild sheet steel - Epoxy powder coated - BS 00 A 05 grey - fine texture

60mm(D)

Model No. K16000L2

90mm(D)

- 3.0Kg

Internal VIew

Page 92


DS56.03.2011

Tamper Resistant Vision Window Retrofit Tamper Resistant Vision Window

Product Overview The Tamper Resistant Vision Window is perfect for public areas where restricted access is necessary to prevent damage and unauthorised operation of the control panel. The cover features a fully welded steel construction and key lockable inner door making it robust and secure. The Vision Window is available from stock, fully assembled, and can be fitted on site in minutes by simply taking out the hinge pins on the existing enclosure, removing the lid before fitting the new Vision Window cover and hinge pins. Control panels can also be supplied pre-fitted with the Vision Window. This applies to any M2 size Sigma CP, Sigma CPA, Sigma CP-R, Sigma XT, Sigma A-XT or Syncro AS control panels. Please contact our sales department for prices.

Features

Technical

2 minutes to fit on site

Product code Size Construction Finish Colour - lid & box Colour - controls plate & labels Weight

Kit available from stock Colour to match standard Control Panel ranges Special colours available on request Fits any M2 sized Sigma CP, Sigma CP-R, Sigma XT or Syncro AS panel

-

K18002 385mm(W) x 310mm(H) x 35mm(D) 1.2mm mild sheet steel Epoxy powder coated BS 00 A 05 grey - fine texture RAL 7047 light grey - satin

- 2.0 Kg

Attractive design Key lockable

Take out both hinge pins & remove lid

Product code: K18002 Fit the Vision Window, then re-fit both hinge pins

The manufacturer reserves the right to amend specifications without prior notice

Page 93


! EW N

Warning Signs Illuminated signs using high intensity LED indicators

Product Overview The new range of illuminated warning signs employ the very latest in LED technology to provide a high reliability, high brightness, audio/ visual warning indication unit. The brightness of the sign remains constant over its entire operating range of 15 to 30 volts DC due to the unique “power boost� circuitry employed. This ensures that even with a system running on depleted batteries, all signs remain at full intensity.

Features High brightness white LED indicators for reliability and low power consumption Standard or easily customisable wording and language variants Split level function - allows top half and bottom half of sign to be illuminated independently with no light spillage between halves Internal buzzer with disable and external silence facility Available in red illuminated or yellow illuminated as standard, other colours available on request

A range of standard text signs are available and customised text and languages are easily accommodated due to the unique method employed to apply the lettering. The split level design allows one message to be displayed in the top half of the sign and an additional message to be displayed in the bottom half of the sign allowing for two stage warnings for systems such as extinguishing protection systems. The signs are now also available in split colours. Red, green or yellow acrylic can be mounted in the top section and the bottom section in any configuration. Text can be printed in black or alternatively can be reversed so the letters appear in the colour of the acrylic.

Connects to standard fire alarm sounder circuits Two wire 2 - stage (top half/ bottom half ) voltage reversing input provided Voltage reversing, silenceable sounder output provided

Split level function

Model No. K27102

Page 94


DS64.03.2011

Panels Product Code Description

Colour

Size (mm)

K27102

Red on black

300 x 195 x 50

Red on black

300 x 195 x 50

Illuminated sign “FIRE ALARM DO NOT ENTER” Illuminated sign “FIRE ALARM EVACUATE AREA” Illuminated sign “EXTINGUISHANT SYSTEM ACTIVATED” Special Designation (specify text) Special Designation (specify text) Special Designation (specify text)

K27101 K27202 X2710 X2720 X2730

Black on yellow 300 x 195 x 50

Specification

Red on black 300 x 195 x 50 Black on yellow 300 x 195 x 50 Black on green 300 x 195 x 50

For dual background versions, contact sales on +44 (0) 1322 222121

Technical Construction Finish Colour - lid & box Power Consumption Operating temperature Operating humidity Operating Voltage

-

1.2mm mild sheet steel Epoxy powder coated BS 00 A 05 grey - fine texture

140 milliamps max at 24V DC -5°C to +50°C To 95% non-condensing -15 to 30V DC

ALARMA DE INCENDIOS NO ENTRAR Special designations example

EXTINGUISHANT RELEASE

SYSTEM NORMAL Special designations example

ENTER DO NOT ENTER

Model No. K27102

Dual background example

SWITCHED -VE STAGE 2

COMMON +24V

SILENCE BUTTON MOUNTED REMOTELY

SWITCHED -VE STAGE 1

TO ADDITIONAL SIGNS OR SOUNDER SOUNDERS OUTPUT

VOLTAGE REVERSING INPUT - TO +

COMMON +24V

SWITCHED -VE STAGE 1

3 WIRE CONTROL

VOLTAGE REVERSING INPUT + TO -

2 WIRE CONTROL

SILENCE

LEV 2

I/P

LEV 1

2 WIRE

COMM +

LEV 2

LEV 1

COMM +

ON

LEV1 FLASH LEV2 FLASH

2 WIRE SOUNDER

O/P

SING/DUAL DISABLE BUZZ ENABLE SILENCE

The manufacturer reserves the right to amend specifications without prior notice

Page 95


Remote Fire Detector Indicator Units

! EW N

Remote Indicator Unit

Product Overview The K24000 Remote Indicator LED Units allow the LED associated with a fire detector to be extended to a visible location in areas where the detector itself is concealed. Two bright, alternately flashing LED indicators with wide angle diffusers ensure that the indicators are immediately visible in any sized room. Special ceiling mounting clip available. Fixing screws supplied with each unit. The round version fits into a BESA box and the square version fits into a standard electrical single gang back box.

Features

Connections for both conventional and addressable detectors.

High brightness red LED indicators for reliability and low power consumption Wide viewing angle LEDs flash alternately to easily attract attention Units to fit to standard gang or round electrical back boxes Compatible with conventional and addressable detectors Printed with “FIRE ALARM IN CONCEALED SPACE� as standard

Ceiling Mounting Clip

Product Overview Our new and unique ceiling mounting clip provides fast and secure fixing of our round Remote Indicator unit to ceilings. Particularly good for fragile ceilings such as suspended ceilings.

Custom printing and languages available on request

Model No. K24000

Page 96

Model No. K24001


DS68.02.2011

Panels Product Code Description K24000 K24001 M24000

Specification

Size (mm)

Round Remote Indicator 85 x 85 x 30 Square Remote Indicator 85 x 85 x 30 Ceiling Mounting Clip 85 x 85 x 30 (fits Round Remote Indicator only)

Technical Construction Finish Colour Current Consumption Operating temperature Operating humidity Voltage

-

1.5mm mild sheet steel Epoxy powder coated White 20 milliamps max at 24V DC

-5째C to +50째C <95% (non condensing) 15 to 30V DC

Ceiling Mounting Clip M24000*

B C

C

D

A

A

D

Fixing Details

1. Make a hole in the ceiling using the most suitable method below: a) Using a standard 64mm diameter hole saw. b) Use an open ended saw to cut a 62mm X 28mm slot. c) If fixing to a ceiling tile, gently push the clip through the tile and use a stanley knife to cut between points C and D (both sides). 2. Fold back the two tabs marked A into position B, locking the ceiling clip into position.

B

3. Use the 2 self tapping screws provided to fit the Remote Lamp plate.

Connection Details Always refer to the detector manufacturers detector base instructions before connecting the K24000 Remote Indicator Unit and only use the connections described. Remote indicators that are not connected as per the instructions may cause the detector to be inoperative.

Detector + Supply

+

+

A -

1K

100R Flashing Red LEDs

Addressable Detector Remote Indicator Output Conventional Detector Remote Indicator Output

* Fits Round Remote Indicator Only (K24000) The manufacturer reserves the right to amend specifications without prior notice

Page 97


EW N

Audio Visual

!

DS63.03.2011

Audible and visual indicator units Providing remote indication of the status of the fire alarm system

Product Overview A range of indicator units with either red or yellow indicators to provide audible and visual status of alarms, isolations or other functions associated with the fire alarm or other systems. These units are available with a keyswitch to silence the internal buzzer or a keyswitch to illuminate the indicator and buzzer and provide a volt free contact for ancillary control functions when the keyswitch is operated.

Features Available with red or yellow high brightness, flashing LED indicators

All units mount to a UK style, single gang back box or can mount to standard surface or flush single gang mounting boxes.

Can be used for Fire alarm warning, activated by a sounder circuit or to indicate and initiate an active isolation Optional silence buzzer keyswitch Disable buzzer option via internal jumper link Optional keyswitch to perform isolation Terminations for incoming and outgoing wiring Fits onto standard, single gang UK back box for flush mounting (use M10FCLGT) Surface mounting box supplied

Panels Product Code

Description

Size (mm)

K24100-M10 Red Fire alarm indicator K24110-M10 Red Fire alarm indicator with buzzer silence keyswitch K24200-M10 Yellow alarm indicator K24210-M10 Yellow alarm indicator with control keyswitch Flush Mounting Collar M10FCLGT (will fit single gang deep flush back box)

97 x 97 x 48 97 x 97 x 48 97 x 97 x 48 97 x 97 x 48

Model No. K24110-M10

Technical Construction Finish Colour - lid & box Voltage Power Consumption Operating temperature Operating humidity

-

1.2mm mild sheet steel Epoxy powder coated BS 00 A 05 grey - fine texture

18 to 30 V DC 25 milliamps at 24V -5째C to +50째C To 95% non-condensing

Model No. K24210-M10

Page 98


DS26.03.2011

Relay Boards Single (RL1) and Four (RL4)

K375 - RL1 Single Way Relay PCB

Way Relay PCB

Product Overview

This simple board contains a single 24V DC relay, which can be used for any extra low voltage switching applications. It has two changeover contacts, an LED indicator to show when the coil is energised and a polarising diode to prevent damage to the power source by reverse polarity connection. The contacts are suitable for switching a maximum of 30V DC and 2 Amps. Voltages or currents that exceed these values should not be connected under any circumstances. The current consumption of the unit when operated from a 24V supply is approximately 25mA. The PCB has four 4mm mounting holes, which will accept the self adhesive standoffs supplied. The use of self adhesive standoffs should be carefully considered however due to their tendency to become detached over a period of time and a more permanent fixing method is recommended.

K376 - RL4 Four Way Relay PCB

RL1- Single Way Relay PCB (K375)

Product Overview

This simple board contains four 24V DC relays, which can be used for any extra low voltage switching applications. Each relay has two changeover contacts, and an LED indicator to show when the coil is energised. The coils of the relays are commoned to the positive supply and the relays can be operated individually by switching a negative to the numbered coil inputs. The contacts are suitable for switching a maximum of 30V DC and 2 Amps. Voltages or currents that exceed these values should not be connected under any circumstances.

RL4- Four Way Relay PCB (K376)

The current consumption of the unit when operated from a 24V supply is approximately 25mA per relay. The PCB has four 4mm mounting holes, which will accept the self adhesive standoffs supplied. The use of self adhesive standoffs should be carefully considered however due to their tendency to become detached over a period of time and a more permanent fixing method is recommended.

NC

Features

COIL

C

L1

L1

RL1

RL1

NO NC

CONTACT 1

C

NC

NO

CONTACT 2

COIL

C

NO NC

CONTACT 1

C

NO

CONTACT 2

24V DC operated LED indicator shows relay operated

AL 0V

NC C NO

ALARM INPUT

ALARM CONTACT

S1

S2

AL 0V

NC C NO

ALARM INPUT

ALARM CONTACT

S1

S2

Two changeover contacts per relay

X1 LK1

L4 R4

R3

RL3

C NO NC

RL4

C NO

D4

R1

R2

RL2

RL1

NC

L3

D3

C

D2

NC NO

SERIAL NUMBER

NO

L2

L1

D1

C

RELAY 4

2 Amp 30V DC contact rating

RL4

NC

RELAY 3

Small footprint

Example sounder interface of two K3000S fire panels RELAY 1

Spring leaf 2.5mm capacity terminals

RELAY 2

Built in suppression diodes

Low current consumption 1 NC C NO 2 NC C NO RELAY 1

RELAY 2

3 NC C NO 4 NC C NO RELAY 3

RELAY 4

The manufacturer reserves the right to amend specifications without prior notice

Page 99


HydroSense System Overview

Hydrosense Water Detection System

A Hydrosense Water Detection System installed in vulnerable areas will continuously monitor the potential hazards around the clock, year in year out. The Hydrosense system has a range of attractive and unobtrusive control panels containing the alarm circuitry, power supply and has the facility for 24 hour battery standby. A Hydrosense System has two methods of leak or moisture detection, Linear or Point detection. Linear detection is provided by Hydrowire moisture sensitive cables which are connected to the control panel via a special Connection Box, by simple two core leader cable making installation quick and inexpensive.

System Features Linear detection with Hydrowire

Point detection is provided by Floor or Drip Tray Probes also connected to the control panel by simple two core leader cable.

Point detection with probes Zonal repeat contacts

Easy to service and maintain

The Hydrowire and Probes are continuously monitored. Any disconnection or fault is immediately indicated on the control panel. All monitoring indicators can be repeated to remote repeater panels or via volt free contacts to a BMS.

Auxillary alarm contacts

Hydrosense Floor and Drip Tray Mounting Probes

Easy to install

The Floor Probe is simply fixed to the floor and adjusted to give the required detection level and connected to the control panel via a simple junction box. The Drip Tray Probe has exactly the same facilities as the floor mounting probe but has a bracket for mounting onto the side of an ACU drip tray.

Monitored alarm outputs Battery backup Remote monitoring

Hydrowire

Control Panels Two types of control panel are available. The Hydrosense HSCP is available in 2, 4 and 8 Zone configurations and the Hydrosense K200000 range for 12 Zones or greater. Flush versions and special finishes are also available.

Available as standard 5 and 10 metre lengths pre-terminated with DIN plugs, Hydrowire is a flexible cable which will continuously monitor large areas. When even a small amount of water or moisture comes into contact with Hydrowire it will trigger an alarm. Hydrowire will dry out in around 20 minutes for use again. Each zone requires a junction box and an end of line plug.

Repeater panels and ancillary PCBs are available to provide common alarm, common fault, coincidence and zonal alarm, VFCs allowing control of sub-systems, graphical mimics and plant, remotely from the main panel over a two wire data bus.

Star Lane, Great Wakering Essex, SS3 0PJ. England Tel: +44 (0)1702 216999 Fax: +44 (0)1702 216699 Email: sales@vimpex.co.uk Web: www.vimpex.co.uk

Page 100

Model No. HSCP-S-8

Model No. K2024005


DS03.14.2011

HSCP Control Panel Features Fully compliant with & tested to BS EN54-2 and BS EN54-4

Specification

Available in 2, 4 or 8 zones 2 wire repeaters and ancillary boards Fully programmable using simple menu options For more Features, Product Overview and Technical details see Sigma CP page 48 and Sigma CP-R page 52

K200000 Control Panel Features 12 - 48 zones as standard, more available on request Common fire and fault contacts Remote signal contact and isolate Zonal one man test For more Features, Product Overview and Technical details see Series 3000 page 56

Matrix Control Panel Features Up to 320 LED’s can be controlled Full colour printing Available in a range of standard enclosures to suit any application Bespoke sized units can be made upon request For more Features, Product Overview and Technical details see Sigma Matrix page 60

Hydrosense Probes

Technical

Equipment

Size

Product Code Description

Indicator Connection Material

- 95mm (max.) 80mm (min.)H x

45mmD x 100mmW - Green LED - 4 pin din flying lead (1 metre) - Black nylon

K2012003 K2016005 K2024005 HSCP-S-2 HSCP-S-4 HSCP-S-8 HSCPR-S-2 HSCPR-S-4 HSCPR-S-8 K2101 K2102 K2103 K2104 K2105 K2106 K2110 K2111 K2112 S 9615/A F/A/1W

12 zone control panel 16 zone control panel 24 zone control panel 2 zone Control Panel 4 zone Control Panel 8 zone Control Panel 2 zone Repeater Panel 4 zone Repeater Panel 8 zone Repeater Panel Floor mounted probe Drip tray probe Remote indicator 5 metre Hydrowire 10 metre Hydrowire Hydrowire connection box End of line plug Leader cable 50M Fixing clips (100) Protection Cage for Floor Mounted Probe Fire-CryerÂŽ with water leakage alarm

Larger control panels are available on request

Model No. K2101 The manufacturer reserves the right to amend specifications without prior notice

Page 101


Custom Engineered Solutions Pages 104-109


The Custom Specialists Our In-house Facilities Page 104-105

Custom Engineered Solutions Page 106-109


Custom The Custom Specialists Our in-house Facilities One of the key areas of our business is the design and manufacture of bespoke equipment. Kentec has considerable expertise in this field with over 25 years experience, so you can be certain that all custom engineered product will be designed and built in accordance with your exact requirements and our strict ISO 9001 approved quality procedures. Many in-house facilities are at our disposal: From the initial design process

To sheet metal fabrication

To painting and printing

To panel construction

We have full control at every stage allowing us to offer industry leading delivery times and with quality you can have confidence in. Page 104


All custom built equipment is project managed by our engineering department, using the latest software to produce electrical, mechanical and construction drawings to the customers specifications.

Specification

We have a dedicated area for the construction of bespoke product and this was enlarged in the first quarter of 2011 to allow us to increase our capacity and offer better service to our customers including factory acceptance testing. Our skilled and dedicated production engineers build each bespoke product to very high standards and to specifications driven by our customers.

The manufacturer reserves the right to amend specifications without prior notice

Page 105


Custom Custom Engineered Solutions

Geographical floor plan with LED indications.

Facilities Expert design advice Mechanical engineering design Artwork and printing design Documentation Electrical engineering Electronic engineering Sheet metal fabrication Powder coat finishing Metal finishing Silk screen printing Wire looming Electrical safety testing Technical support

Analogue Addressable fire control panel with plant controls.

Floor standing fire detection control panel with geographical floor plan & plant controls.

Page 106


DS38.03.2009

From Concept . . . . Conceptual drawing produced and sent to client for approval

Specification

543.0

Firemans Override

OFF AUTO

398.0

GENERATOR FAULT

ON

AUTO

LWR. GRD. SMOKE CLEAR ASSIST

OFF

SHUT

On approval, parts are engineered & sent to sheet metal shop for fabrication before going to paint shop (choice of finishes)

SHUT

GAS VALVE SHUT

OFF

AUTO

ON

AUTO

STAIR PRESSURISATION

ON

AUTO

BUILDING SMOKE CLEAR ASSIST

OPEN

OPEN

ATRIUM LOUVRE OPEN

WARNING 240V AC ENCLOSED WITHIN

YOUR LOGO

NOTES:

MATERIAL: FINISH:

18SWG MILD STEEL

35.0

EPC - WHITE SCREENING - BLUE

REV

REVISION

A

DATE

R./C. NOTE No.

FOR APPROVAL

24.1.06

B

FOR INFORMATION

26.1.06

C

FOR INFORMATION

1.2.06

500.0

97.5

90.0

90.0

90.0

30.0

130.0

PROJECT:

45.0

SPECIAL FIREMANS CONTROL PANEL C/W VISION WINDOW COVER FASCIA DRAWING TRIANGLE INTERGRATED FIRE

DATE:

SCALE:

24.1.06

DWN BY:

CHK BY:

PM

NTS

W/O No.

35.0

CLIENT:

DRAWING No.

31611

D4

REV:

C

130.0

K7903-01

L

L

L

L

L

L

L

L

N

80.0

355.0

CL

CL

Detailed electrical schematic diagrams are produced for production and record purposes 12.0

7.0

18.5

 

E

WELD & FULLY CLEAN CORNERS, SURFACE TO BE FLAT, SMOOTH & SQUARE BEFORE FINISHING







NOTES:

 

 











 



 

 















 

 

 

   



 



 







 

 

















  















REV

01



UNLESS OTHERWISE STATED ALL DIMENSIONS IN MILLIMETRES, TOLERANCES AS FOLLOWS:

  

 



 



SPECIAL FIREMANS CONTROL PANEL C/W VISION WINDOW COVER INNER LID DETAIL





PROJECT:

MATERIAL: 18SWG MILD STEEL FINISH: EPC - WHITE

 

REVISION

FOR PRODUCTION

REL/C.NOTE No.

DATE

R31611/1

1.2.06

CLIENT: DATE: 1.2.06

x.x = +- 0.3 x.xx = +- 0.05

W/O No. 31611

TRIANGLE INTERGRATED FIRE SCALE: NTS

DWN BY: PM

CHK BY:

DRAWING No. K7903-03

REV 01



 

 





 





 





 

 



 



 

 



 

 



 

 





 



Silk screen artworks are generated in house for use in our printing shop



 

 





                 





       

 

 











Firemans Override

 

 















 



OFF AUTO

GENERATOR FAULT

SHUT

GAS VALVE SHUT

SHUT

OFF ON

STAIR PRESSURISATION

Unit is then assembled, fully tested and dispatched to address of your choosing!

AUTO

LWR. GRD. SMOKE CLEAR ASSIST

OFF AUTO

ON

AUTO

ON

BUILDING SMOKE CLEAR ASSIST

AUTO

OPEN

ATRIUM LOUVRE OPEN

OPEN

BLUE S.P. TRIANGLE CLIENT: 1.2.06 DATE: R31611/1 R.NOTE: Dwg. No: K7903-02 CHK. BY PM DWN. BY SCALE: 1:1 REV: 01

WARNING 240V AC ENCLOSED WITHIN

. . . . To Product Special Firemans Control Panel The manufacturer reserves the right to amend specifications without prior notice

Page 107


Custom Custom Engineered Solutions

. . . . choose your finish

. . . . choose your colour . . . . choose your specification Applications Smoke Damper Control Panels Composite Relay Units (c/w Resettable Latching Relay & Firemans Switch) Sprinkler System Indicator Panels Pump Status Indicator Panels Firemans Control Switch Panels Analogue/Addressable Interface Units (with or without integral PSU) Mimic Repeat Indicator Panels (perspex/metal, metal only, black & white or multi-coloured)

Page 108


Specification

Bespoke Fire Alarm Control Panel housed in a special compact enclosure to suit customers building layout.

Floor standing triple width enclosure with glazed doors. Unit features geographical floor plan layouts and 3rd party voice alert system.

The manufacturer reserves the right to amend specifications without prior notice

Page 109


Enhanced Training from Kentec Due to the success of the Regional Syncro Training Seminars that have been running for the past two years throughout the UK, we have now extended this to 2011. Each course is split over two days. The first day is the Syncro Foundation Course and the second day builds on this by providing hands-on training on networking, expansion cards and configuring complex systems. We can also provide product training on the Guide graphics system and our Extinguishing control panels, either at our offices or at customer locations in the UK and Internationally by prior arrangement. For more information on training or to register, please visit our web site www.kentec.co.uk and click on the “Training” tab. Alternatively please email training@kentec.co.uk.

Are you ‘In the loop’? Kentec’s popular ‘In the loop’ e-mail bulletin has now been a regular feature for over six years, providing articles on a variety of subjects including news about new products, enhancements to existing products and many other subjects relating to our products and services along with general industry information. If you would like to be ‘In the loop’ you or a colleague can register for free on our web site by visiting www.kentec.co.uk For the more technical user we also produce the technically biased ‘In the technical loop’ e-mail bulletin, which can also be subscribed to by visiting www.kentec.co.uk For back issues of either publication please visit our web site.

Marine approvals for Syncro ASM Syncro ASM analogue addressable, fire detection systems are available from Kentec Electronics Limited, for a wide range of marine fire alarm system applications. Syncro ASM fire control panels can be networked to provide scalable fire alarm systems, suitable for many classes of vessel. For more information please visit our web site www.kentec.co.uk and click on the ‘Marine’ tab. Alternatively please contact our sales department on 01322 222121.

0086/11


How to find us? Train The nearest station is Dartford which is served by trains from Charing Cross, London Victoria. Journey time approximately 40 minutes from Central London. From M25 Clockwise Leave M25 at Junction1b (signed Dartford & A225). At the roundabout, take the third exit onto the A225. Continue straight across the next roundabout and continue to a set of traffic lights. Turn left at lights onto Darenth Road. Turn right onto Powder Mill Lane. Turn left into Fawkes Avenue. We are located on the right. From M25 Anti-Clockwise Leave M25 at Junction 2 (signed London, Canterbury, A2 (M2) & Dartford (A225). At the roundabout, take second exit and follow slip road towards Junction 1b, At roundabout take first exit onto the A225. Continue straight across the next roundabout and continue to a set of traffic lights. Turn left at lights onto Darenth Road. Turn right onto Powder Mill Lane. Turn left into Fawkes Avenue. We are located on the right.



Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.