SKYLITE
Installation Manual
English
ATTENTION: In order to function properly, SkyLite must be connected to a dimmable driver/ballast. NOTE: Some dimmable drivers/ballasts must be programmed/set to dimmable mode. If this has not been done, SkyLite will not be able to dim the connected armature. Ensure that the armature is connected using a 5-core cable. If this has not been done, SkyLite will not be able to dim the connected armature.
TVILIGHT BV / Westerhaven 13, 9718 AW Groningen, the Netherlands +31 (0)50 800 3240 / info@tvilight.com / www.tvilight.com
v 1.2 22/04/2015
In box:
M12 Cable Gland
5m Cable
You’ll need: Drill
M12 Thread
Generic Strap
Max = 13mm Min = 8mm
Wago/3M ScotchLok Connector
Level
Page 1 of 6
1. Run wire through cable gland
2. Drill M12 threaded hole into pole
5m
Page 2 of 6
3. Run wire through hole
4. Screw cable gland into hole Rotate the cable gland to tighten
Page 3 of 6
5. Strap product to pole
Generic Strap
6. Apply product ID sticker to pole Ensure ID sticker of product and pole are the same
SAME
5 cm
Page 4 of 6
Wiring Diagram
Connector (e.g. Wago/3M ScotchLok)
WARNING: If not correctly connected product will not function.
DC -
AC in(N)
DC +
Grey
AC in(L)
Purple/Black
Blue
Junction Box
Brown
AC in(L) AC in(N)
DC +
DC -
Page 5 of 6
Wiring Diagram Armature (Armatuur) GND DC - DC + LL NN GND DCDC+
WARNING:
Tvilight CitySense SkyLite
If not correctly connected product will not function.
DC+ DCDC + DC -
LL
N N
Connector DC + DC+
Connector
Junction Box
DC DC-
(Aansluitset) LL N N
LL NN GND GND
GND GND
AC in(L)
AC1 AC2 AC3 AC1
AC2
AC3
To Mains (Naar Mains)
Brown
AC in(N)
Blue
DC +
DC -
Purple/Black
Grey
Note: For added protection, it is recommended to add an external circuit breaker at the power input of the product. Circuit breakers such as the TYCO W33-S1N1Q-20 or similar rated products could be used for the same.
Page 6 of 6