Tyler Neill | Interior Design Portfolio

Page 1

TYLER NEILL

INTERIOR DESIGN PORTFOLIO | CURATED WORKS


OVERVIEW


TYLER NEILL, NCIDQ, IIDA 931.802.9372 | tneill92@hotmail.com https://www.linkedin.com/in/tylerneill/

EXPERIENCE MAY 2017 - Interior Designer | Design 615 MAY 2020

EDUCATION MIDDLE TENNESSEE STATE UNIVERSITY CLASS OF 2015

ACCREDITATIONS NCIDQ no. 34571

Concept Presentation & Custom FF+E Selection, Presentation Packages, Field Verification, Design Development, Construction Documentation, Prepared bids, Project Management, Submittal Reviews, IBC & ADA Codes Knowledge, Construction & Final Punch Meetings, Managed Out-of-House Consultants - Engineering, Architects, etc.

SEPT. 2016 - Project Designer | FH Design MAY 2017

Design Development, Concept Presentations, Custom FF+E, Field Verifications, Initial Client & Site Meetings, Renderings, Presentation Packages, Installation Coordination, Specsources Implementation for the Company

ORGANIZATIONS IIDA VP OF MEMBERSHIP 2018-2020 NASHVILLE CIVIC DESIGN CENTER

MAR. 2015- Project Designer | Interior Design Services (IDS) SEPT. 2016 Renderings, Presentation Packages, Field Verification, and Construction Documentation, Artwork + Signage coordination on Projects, IBC & ADA Codes Knowledge



CONTENTS 01 The Manning

02 Rocky McElhaney Law Firm

03 Nissan Smyrna Trim & Chassis Office Renovation

04 Titans Owner Suite

05 Applied Health


01

The Manning A new construction project to come in Bellemeade, the client requested an aesthetic that felt “free of clutter” and stripped away of the unnecessary. Providing a back-drop of bright whites and soft neutrals, the otherwise understated aesthetic is punched with bold pops of color seen in artwork and decor.

PRELIMINARY CONCEPTS - DESIGN DEVELOPMENT - FF+E



THE INSPIRATION FLOORPLAN



02

Rocky McElhaney Law Firm Rocky McElhaney Law was ready to relocate his headquarters with a new vision in mind for the structure and aesthetic of the building. A previous resident and lover of historic buildings, Rocky wanted to stay true to his companies roots while infusing the flair of an ultra-modern aesthetic. Design 615 partnered with Manuel Zeitlin Architects on the architecture to achieve Rocky’s narrative by juxtaposing dynamic, protruding angles against historic brick.

DESIGN DEVELOPMENT - CONSTRUCTION DOCUMENTS CONTRACT ADMINISTRATION



THE INSPIRATION GROUND FLOOR

CONSTRUCTION PROGRESS


CUSTOM DESK RENDERINGS

FINAL PHOTOGRAPHY


03

Trim & Chassis Office Renovation With their team expanding, the client looked to renovate an under-utilized locker room in one wing of the manufacturing facilty. The project narrative was simple - provide an environment with an abundance of light and a design that felt “techy and innovative” while working on a tight budget a timeline.

CONCEPTS & DD - FF+E - CONSTRUCTION DOCUMENTS CONTRACT ADMINISTRATION



THE INSPIRATION

MW MW

TV

VESTIBULE 100

TV

TV

COFFEE KEURIG

HUDDLE 102

COLLAB CONF. 103

AGILE MTG.

TV

AGILE MTG.

REF

NTV

COPIER

OPEN OFFICE 101 CONFERENCE 109

ICE

ACCESSIBLE BENCH

TV COPIER

BREAK ROOM 104

COPIER

NTV

REF

REF

TRASH

TRASH

TV

MOTHER'S ROOM 105

TV

SR. MGRS 107

CONFERENCE 108

PRE-CONSTRUCTION SITE PHOTOS

MOTHER'S ROOM 106


REFLECTED CEILING PLAN KEYNOTES CONTRACTOR SHALL PERFORM THE WORK INDICATED BY THESE NOTES IN AREAS DESIGNATED ON THE PLAN SPECIFIC KEYNOTE NUMBER.

1

UNDERSIDE OF GYPSUM HEADER TO BE AT 8'-0" AFF.

2

UNDERSIDE OF GYPSUM HEADER TO BE AT 8'-0" AFF AND TOP AT UNDERSIDE OF THE CEILING. REFER TO ARCHITECTURAL PLAN, SHEET ID 1.1 FOR DIMENSIONAL EXTENTS OF NEW WING WALLS.

3

UNDERSIDE OF GYPSUM HEADER TO BE AT 9'-2" AFF AND UP TO DECK.

4

PROVIDE WHITE NOISE SYSTEM FOR OPEN OFFICE 101 AND SR. MGRS 107 OFFICE. SYSTEM TO HAVE 2-TYPES OF HEAD OPTIONS - RECESSED FOR ACOUSTIC CEILING TILE (WHITE FINISH) AND PENDANT MOUNT FOR OPEN CEILING AREA (BLACK FINISH). PROVIDE SUBMITTAL OPTIONS FOR REVIEW, SELECTION, AND APPROVAL OF PROPOSED SPEAKER LAYOUT AND CONTROL PANEL LOCATION.

5

DRIVER FOR FULLY CONCEALED LED LIGHTING TO BE LOCATED IN CEILING ABOVE.

DESIGN 615 MAIN STREET | 615.4

CONSTRUCTION PROGRESS

LIGHT FIXTURE SCHEDULE A LED RECESSED LINEAR LUMINAIRE MANUFACTURER: CURRENT BY GE STYLE/MODEL #: LALR SERIES FINISH: WHITE LAMP: 4000K NOTE: 8'-0" LENGTH

5

EM

C

COPIER

A

B

B

B

OPEN OFFICE 101

H

E

9'-0" AC-1

F

OPEN DECK

G F

4

E

H

C

1

E

B

BREAK ROOM 104

EM

COPIER

MOTHER'S ROOM 105 H

E E

E SUSPENDED LINEARS MANUFACTURER: CORONET STYLE/MODEL #: U SQUARE FINISH: BLACK LAMP: 4000K NOTE: 8'-0" LENGTHS, BLACK CORD AND CANOPY COORDINATE WITH DESIGNER ON SUSPENSION HEIGHTS PRIOR TO INSTALLATION.

A

B

9'-0" AC-1

H

F PENDANTS MANUFACTURER: ASTRO STYLE/MODEL #: ZEPPO PENDANT 400 7786, SKU 1176007 FINISH: WHITE LAMP: E26/MEDIUM COORDINATE WITH DESIGNER ON SUSPENSION HEIGHTS PRIOR TO INSTALLATION.

B

H

H

D

D

D

D

A

B

B

B

B

B

B

9'-4" AC-1 1

B

E

4

B

B

B

B

B

B E

E

B

3

LIMIT OF CONSTRUCTION

CT-3

CT-1, CT-2, AND CT-3 IN SPECIFIED PATTERN SHOWN

HARDWARE AS SPECIFIED

VW-1

C ID5.1

OWNER-PROVIDED ICEMAKER

20 1/2"

2"H PL-2 FLOATING SHELF WITH FULLY-CONCEALED BRACKETS AND FULLY RECESSED LIGHTING - 3/4" TUBE STEEL WELDED TO 1/4" STEEL PLATE BOLTED TO STUDS

FAUCET AS SPECIFIED

QZ-1 COUNTERTOP AND 4' 0 BACKSPLASH

8'

16 1/2"

4"

OWNER PROVIDED ADA HEIGHT REFRIGERTOR. VERIFY EQUIP. REF

4"

34"

1"

24"

24" ±

34"

RB-1

PL-2 BASE CABINETS RB-1

INTERIOR DES

ELEVATION @ BREAK ROOM 104 0

FULL-HEIGHT DOORS WITH FULLY CONCEALED APRON

(3) EQUAL 37 1/2" CLEAR

78"

PLANS AND ELEVATIONS 2'

8'

HARDWARE AS SPECIFIED

CONTRACTOR TO PROVIDE REFRIGERATOR. COORDINATE MILLWORK CLEARANCE WITH EQUIPMENT SPECIFICATION

4"

REF (NIC)

34"

ICE (NIC)

40" MAX

22"

22" 34" 4"

4"

29"

24"

4'

AS SPECIFIED - CENTERED ON SINK

FULL-HEIGHT DOORS WITH FULLY CONCEALED APRON

MW

RB-1

2

ROOMS ARE TO HAVE OCCUPANCY/MOTION PHOTO SENSORS, OR DUAL SWITCHING, IN COMPLIANCE WITH THE INTERNATIONAL ENERGY CONSERVATION BACKLIT/EDGELIT MIRROR CODE.

REFLECTED CEILING PLAN

QZ-1 COUNTERTOP AND BACKSPLASH

12" MW

THIS DRAWING I DESIGN 615, UNAUTHORIZED REP WITHOUT THE PRIO CONSENT OF D

NOTE: LIGHTING LAYOUT AND SWITCHING IS FOR DESIGN INTENT ONLY. FINAL LIGHTING LAYOUT TO BE DETERMINED BY ENGINEER'S OR CONTRACTOR'S CALCULATIONS AND COMPLIANCE WITH THE INTERNATIONAL ENERGY CONSERVATION CODE AS REQUIRED BY JURISDICTION. PROVIDE COMCHECK IF REQUIRED.

CONTRACTOR TO PROVIDE MICROWAVES - VERIFY EQUIPMENT SIZES. PL-2 SURROUNDS.

B ID5.1

PL-2 BASE CABINETS

B

NOTE: MOTHER'S ROOMS 105 & 106 ARE MIRRORED VERSIONS OF EACH OTHER. REFER TO PLAN FOR DETAILS AND PROVIDE APPROPRIATE SHOPS AS NECESSARY.

PL-2 FALSE PANEL

15"

QZ-1 COUNTERTOP

B

E

EM

21"

FULL-HEIGHT DOORS WITH FULLY CONCEALED APRON

SR. MGRS 107

1

B

PL-2 UPPER CABINETS

FAUCET AS SPECIFIED

B

E B

H EDGELIT MIRROR MANUFACTURER: ELIO STYLE/MODEL #: LOOK OUTER ETCHED FINISH: N/A LAMP: 4000K NOTE: 24"Wx36"H, 69455.ELS.2436.30K-3P120

OWNER-PROVIDED KEURIG AND COFFEE MAKER - VERIFY EQUIP. HEIGHTS

MOTHER'S ROOM 106 9'-0" AC-1

E

H

CONFERENCE 108

CT-2

9'-4" AC-1

H

9'-0" AC-1

B

4 E

9'-0" AC-1

G LARGE PENDANT MANUFACTURER: GROK STYLE/MODEL #: UMBRELLA PENDANT 00-2726-AP-05U FINISH: BLACK LAMP: E26 COORDINATE WITH DESIGNER ON SUSPENSION HEIGHTS PRIOR TO INSTALLATION.

E E

H

H

CT-1

B

EM

1

CONFERENCE 109

COLLAB C CONF. 9'-0" 103 AC-1

9'-0" AC-1

COPIER

2

D UNDER CABINET/SHELF LIGHTING MANUFACTURER: PURE EDGE STYLE/MODEL #: LIGHT CHANNEL COMPLETE FIXTURE 0.6" MILLWORK RECESSED, LCMW.6 FINISH: DIFFUSER LENS LAMP: 4000K

'EM' EXIT LIGHT EMERGENCY LIGHT COMBO SUREL-LITES LPXC SERIES FINISH: WHITE LAMP: LED NOTE: OR BUILDING STANDARD EQUAL

C

9'-0" AC-1

C LED RECESSED LINEAR LUMINAIRE MANUFACTURER: CURRENT BY GE STYLE/MODEL #: LALR SERIES FINISH: WHITE LAMP: 4000K NOTE: 4'-0" LENGTH

D

C

VESTIBULE 100

NISSAN SMYRNA

HUDDLE 102

ACCESSIBLE BENCH

TV

C

B LED 2x4 RECESSED LUMINAIRE MANUFACTURER: CURRENT BY GE STYLE/MODEL #: LVT 24 SERIES FINISH: WHITE LAMP: 4000K

3 4'

ELEVATION @ MOTHER'S ROOMS 105 & 106 4'

2'

0

4'

ISSUE DATE: PROJECT NUMBER:


04

Titans Owner’s Suite The Titan’s Stadium originally opened in 1999, leaving the original private suites ready for a face lift. The stadium was only continuing to attract attention as Nashville was growing as a major city in the eyes of both tourists and potential new residents. As concerts began using the stadium as a venue, the client knew that it was time that the new look of the suites reflect the clientele who would rent them. The design intent was simple: provide a clean, elegant suite to serve as a sophisticated backdrop that would not distract from the views of the game.

CONSTRUCTION DOCUMENTS - CONTRACT ADMINISTRATION



PRE-CONSTRUCTION SITE PHOTOS REF

REF

FEC

DW

EX TLT 302

CL 301

ENTRY 300

PANTRY 308

FE EX TLT 303

ICE

EX TV

TV

BAR 307

TV

COOLER COOLER

FOOD LAYOUT 304 RE TV

MOBILE TABLE COMMUNITY TBL LOUNGE 306 EX TV

EX TV

DN

DN

EX SEATING 305

DRINK LEDGE (OVERHANG) WALL (PARTIAL HT) GLASS SYSTEM

LIMIT OF FF&E

FIN


CONSTRUCTION PROGRESS

NAL PHOTOGRAPHY


05

APPLIED HEALTH Relocating from their office in the center of downtown, it was time to update the overall aesthetic of what the client had been used to for several years. As a healthcare analytics company, it was important to reiterate that in the design whilst ensuring every element functioned for them when due to dealing with confidential inormation.

DESIGN DEVELOPMENT - FF+E - CONSTRUCTION DOCUMENTS - CONTRACT ADMINISTRATION


IN COLLABORATION WITH SW DESIGN GROUP


THE INSPIRATION 6'-8 1/2"

PHI CLST. 615 TRASH

65" TV

RECYC.

BREAK 609

70" TV

204

WOMEN

MEN

205

203

24X48 RACK

5'-0"

SALES COLLAT.

9'-6"

14'-0"

RICHARDS & RICHARDS

24X48 RACK 24X48 RACK

9'-1" PRINTER

25'-0"

I.T. 601

WORK/ COPY 611

OFFICE 606

OFFICE 603

14'-0"

COLLAB. 612

VESTIBULE

OPEN OFFICE 608

SECURE HARDWARE SHELVES

16'-7 1/2"

208

10'-1"

H20

4'-9"

SUPPLY 613

MW MW

VESTIBULE

REF

207

REF

FEC

MEN

OFFICE 607

17'-0 1/2"

DW

2S1

14'-0"

CR

STAIR 1

206

13'-4"

COFFEE

UP

WOMEN

34'-7"

3'-3"

TOWER

4'-0"

3'-4" 14'-0"

15'-9" OFFICE 602

OFFICE 604

FILZFELT HANGING + SLIDING SCREENS

CONFERENCE 610 18'-6"

REF

70" TV

SUPPLY 614

OPEN OFFICE 605

STAIR 2 2S2

UP

CLOSET 209 ELEVATOR LOBBY CR

15'-10"

210

PRE-CONSTRUCTION SITE PHOTOS 8' 4' 0 *NOTE: THIS PLAN IS A DESIGN INTERPRETATION OF CLIENT'S PROGRAM. THIS PLAN IS NOT FOR CONSTRUCTION, SPACE PLAN ONLY.

1/8" = 1'-0":

8'


plan symbols RCP plan

plan

RCP plan general notes

Ceiling Surface Mounted Pendant Fixture

a Not In Contract

Wall Mounted Sconce Fixture

3

Three Way Light Switch

D

Dimmer Switch Projection Screen Switch

S

MODIFY EXISTING MECHANICAL SYSTEM TO PROVIDE SEPARATE ZONING FOR EACH EXPOSURE. BALANCE ALL ZONES AFFECTED BY CONSTRUCTION. PROVIDE TEST AND BALANCE REPORT TO BUILDING OWNER AND ARCHITECT FOR REVIEW. A COPY OF THE BALANCE INFORMATION SHALL BE SUBMITTED TO BUILDING REPRESENTATIVE UPON COMPLETION OF THE WORK.

REFER TO GENERAL NOTES SHEET G0.0 FOR GENERAL CONDITIONS AND REQUIREMENTS FOR ALL CONSTRUCTION.

Wiring Arc - Indicates Switching of Fixtures/Devices.

al Ceiling Grid

escent Fixture

escent Fixture with

CONTRACTOR TO PERFORM THE WORK OUTLINED IN THESE NOTES IN ALL AREAS OF CONSTRUCTION UNLESS NOTED OTHERWISE IN THESE DOCUMENTS.

Ground Fault Interrupt Receptacle Location

GFI R

Indicates Electrical Component to be Relocated

E

Indicates Existing Electrical Component to Remain

J

Junction Box Above Ceiling

Fire Strobe and/or horn as specified by Codes

Wall Washer

WALL TO CEILING FEATURE TO HAVE INTEGRATED LED LIGHTING. REFER TO SECTIONS & ELEVATIONS, SHEET A5.1 AND 5.2 SERIES, FOR DETAILS.

2

UNDERSIDE OF GYPSUM HEADER TO BE 8'-0"H.

3

CONSTRUCT A GYPSUM HEADER AT THE GLASS OFFICE FRONT SYSTEM WITH THE UNDERSIDER AT 8'-0"H AFF.

4

DASHED LINE INDICATES ARCHITECTURAL FEATURE OPENING. REFER TO SECTIONS & ELEVATIONS, SHEET A5.1 SERIES, FOR DETAILS.

5

DASHED LINE INDICATES TRACK FOR CEILING-MOUNTED ACOUSTICAL PANEL SYSTEM.

SUPPLY AND INSTALL NEW LIGHT FIXTURES AS SPECIFIED.

A

SUSPENDED LINEAR, 3.25" X 8' MANUFACTURER: FLUXWERX STYLE/MODEL #: PROFILE (F) - FLAT FINISH: BLACK POWDERCOAT LAMP: LED SPEC: 8' LENGTH NOTE: INSTALLATION DIMENSIONS TO B CLOSELY WITH DESIGNER PRIOR TO IN UPLIGHT/DOWNLIGHT PERCENTAGES WITH DESIGNER PRIOR TO ORDERING CONTACT: HANNAH HALL, 615.406.933 HANNAH@TNLTG.COM

B

SUSPENDED CAN LIGHT MANUFACTURER: ATLANTIC LIGHTING STYLE/MODEL #: VR SERIES, CYLINDER 6 FINISH: BLACK LAMP: LED CONTACT: HANNAH HALL, 615.406.933 HANNAH@TNLTG.COM

C

PENDANTS MANUFACTURER: TECH LIGHTING STYLE/MODEL #: FACETTE GRANDE PEN FINISH: BLACK/SMOKE LAMP: N/A CONTACT: HANNAH HALL, 615.406.933 HANNAH@TNLTG.COM

D

WALL SCONCES MANUFACTURER: MARSET STYLE/MODEL #: AURA - JOAN GASPAR FINISH: TRANSPARENT SMOKED LAMP: LED NOTE: PROVIDE AN ALLOWANCE OF $4 CONTACT: ELAINE ELDER, 404-431-823 Elaine@illumco.com

F

SUSPENDED LINEAR, 1X4 MANUFACTURER: EATON STYLE/MODEL #: SLSTP LENSED LED - ME FINISH: STANDARD LAMP: LED SPEC: 4' LENGTH CONTACT: HANNAH HALL, 615.406.933 HANNAH@TNLTG.COM

EXISTING EXIT SIGNS AND EMERGENCY LIGHTING ARE TO REMAIN. CONTRACTOR SHALL EVALUATE LOCATION OF THESE FIXTURES AND MODIFY IF NECESSARY TO ACCOMMODATE NEW CONSTRUCTION AND TO COMPLY WITH CODES.

CEILING HEIGHT IS TO THE OPEN DECK UNLESS NOTED OTHERWISE.

NOTE: Switching within Office Spaces to be controlled via dual switching or occupancy / motion sensor, as per International Energy Conservation Code

ED Fixture

1

ALL LIGHTING AND/OR SWITCHING SHALL BE COORDINATED WITH BASIC BUILDING SYSTEMS. REFER TO BUILDING REPRESENTATIVE FOR REQUIREMENTS.

EMERGENCY LIGHTING LAYOUT IS SHOWN FOR REFERENCE ONLY. CONTRACTOR SHALL EVALUATE EMERGENCY LIGHTING LOCATIONS AND COORDINATE WITH INDICATED DESIGN INTENT. EMERGENCY LIGHTING SHALL COMPLY WITH CODE REQUIREMENTS.

Emergency Lighting Fixture

er mergency Ballast)

ALL ABOVE CEILING SYSTEMS SHALL BE DESIGNED TO ACCOMMODATE CEILING HEIGHTS DOCUMENTED AND CEILING FIXTURES SPECIFIED. CEILING DROPS WILL NOT BE CONSIDERED TO ACCOMMODATE REROUTING OF SYSTEMS.

CEILING ELEMENTS (LIGHTING FIXTURES, MECHANICAL DIFFUSERS, SPRINKLER HEADS, ETC. ARE SHOWN FOR LAYOUT AND DESIGN INTENT ONLY. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION.

light fixture schedule

CONTRACTOR SHALL PERFORM THE WORK INDICATED BY THESE NOTES IN AREAS DESIGNATED ON THE PLAN SPECIFIC KEYNOTE NUMBER.

ALL ADJACENT SWITCHES SHALL BE GANGED IN A SINGLE BOX WITH A SINGLE COVER PLATE. IF GANGING OF SWITCHES IS NOT POSSIBLE, INDIVIDUAL SWITCHES SHALL BE SPACED AN EQUAL AND MINIMUM DISTANCE APART AND LOCATED AT THE SAME ELEVATION AFF. STACKING OF SWITCHES MAY BE NECESSARY IF THE NUMBER IS EXCESSIVE.

Exit Sign (Arrow if Directional Required)

wall Soffit

key notes reflected ceiling plan

RCP plan general notes

Single Pole Light Switch

Surface Mounted Fixture

nce ce

SWITCHES ARE TO BE MOUNTED TO ALIGN WITH THE CENTERLINE OF THE DOOR LEVER 42" AFF. EACH ROOM TO BE SWITCHED INDIVIDUALLY UNLESS NOTED OTHERWISE.

ED Fixture

CONSTRUCTION PROGRESS

LINEAR LED W/ILLUMINATED 90° CORNER MANUFACTURER: EATON STYLE/MODEL #: 2"W, NEORAY DEFINE FINISH: BLACK LAMP: LED SPEC: PER ELEVATIONS. MOUNT TO WA CEILING. NOTE: FIXTURES ARE RECESSED IN WOO CEILING WITH SCONCE INDICATING PORTION. SCONCE + LINEAR = 90° IL FOR WALL & CEILING FIXTURE. SEE D ASSUME (3) CEILING FIXTURES, (2) WA CEILING-TO-WALL FIXTURES. CONTACT: HANNAH HALL, 615.406.933 HANNAH@TNLTG.COM

H

E

UP

STAIR 1

B

B

2S1

E

C

PHI CLST. 615

B

C

B

B

OFFICE 607

B

C F

JANITOR 207A

B

F

B

MEN

A

BREAK 609

EM

A

B

A J

B H20

207

SUPPLY 613

VESTIBULE

OPEN OFFICE 608

E

D

208 VESTIBULE

COLLAB. 612

D

F

I.T. 601

B

204

WOMEN

WOMEN

MEN

205

203

206

B

EM

B A

RICHARDS & RICHARDS

2

D

J

D 4

J

WORK/ COPY 611

EM

D

A

OFFICE 606

3

F

A

SUSPENDED LINEAR, 2"X8' MANUFACTURER: EATON STYLE/MODEL #: NEORAY DEFINE 2 FINISH: BLACK LAMP: LED SPEC: 8' LENGTH CONTACT: HANNAH HALL, 615.406.933 HANNAH@TNLTG.COM

B

OFFICE 603

F

2

PRINTER

B B

A

EM

B

EM

B

A

B

A

B

EM

B

A

A

A

A

EM

B 5

OFFICE 602

B

B

B 3

CONFERENCE 610 B

D

A

D

A

OFFICE 604

B

B

B

F

EM

F

B

SUPPLY 614

B

B B

B

A

F

EM 2

B

OPEN OFFICE 605

EM B

B

STAIR 2 2S2

EM

EM

H

1

3

2

D

D

D

D

D

UP

1'-11"

CLOSET 209

2'-6"

ELEVATOR LOBBY E

enlarged reflected ceiling plan @ lobby:

210

MP&E COORDINATION IN TANDEM WITH DESIGN

reflected ceiling plan:

1/2" = 1'-0":

2'

1'

0

2'

1/8" = 1'-0":

8'

4'

0

8'



Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.