C35

Page 1

1 2

Optional Timer I-36 (When using T36 or dial T37 stats)

6 7 4 5

2

01

01

02

02

Auto Link

Auto Link

03

04

05

05

06

06

2

Basic Dial Thermostat T-37

1

04

Digital Thermostat T-36

1

03

2

Auto Link

UPONOR C-35 CONTROL CENTRE

1 2 11 12

1

Digital Thermostat with Timer Functions T-38

07

Fig.1

Time zone 1 Time zone 2 No time control

One of these three terminals must be connected from the Controller C-35 to a thermostat if a thermostat is used for this channel

This terminal must be connected from the controller to a thermostat if a thermostat is used for this channel

POWER

Connect to Switch Live (A)

Switched Fuse Spur 3 Amp Fuse

Controller (C-35) notes, The diagram below shows the Controller (C-35) linked to an optional Timer (I-36), five thermostats and ten 24V actuator heads. Only 6 of the 12 channels are shown for clarity. Each thermostat requires two cables to be wired to two of the four thermostat connections. The bottom connection must be made. The second wire should be connected to one of the three remaining terminals depending on whether the Timer (I-35) is being used and if so, which of the two time channels is being used. See Fig 1.

E

L

N