Connect to switch
Mechanical Schematic
live demand*
Compact Control Pack V5 Ref: CCP-1.0A
* Refer to air temperature electrical schematic for connection.
Safety High Limit Thermostat
Lockshield Valve
Fill/Drain Point
Supply Sensor
Boiler Return Connect to boiler demand. (refer to boiler manufacturer for details). N
Thermostatic Head
Underfloor Heating Pump
N 24V Uponor Actuators
Manifold
Length
2 Port
340mm
3 Port
390mm
4 Port
440mm
5 Port
490mm
6 Port
540mm
7 Port
590mm
8 Port
640mm
9 Port
690mm
10 Port
740mm
11 Port
790mm
12 Port
840mm
The height of the compact control pack with manifold is 350mm and 135mm deep. The manifold needs to be mounted at least 300mm from the floor.
Notes, 1) A bypass is recommended on the primary circuit. 2) The drawing excludes isolating & regulating valves for clarity. 3) All items to be installed in accordance with manufacturer's instructions and current best practices. Uponor reserve the right to alter specifications and operating parameters for all their systems at any time as part of their policy of continuous product development.
Boiler Flow A
B
Fill/Drain Point
2 Port Motorised Zone Valve
Pump Isolator
Manifold length - see table