Eca 60 remote control instructions

Page 1

veltamat 3D Remote Control ECA 60

User's Operating Instructions 3/2001

SICHER IST SICHER.


Standard Display Room Temperature (Actual)

The white arrow indicates the current operations mode: Automatic change between heating and reduced operation mode Heating mode Reduced temperature mode Required room temperature (set as required)

External temperature Open the lid. Press these buttons to change the required temperature (during normal or reduced operation modes).

The plus and minus buttons are also used to change the temperature for night operation or for long absences (also see pages 6 and 7).

2

vdN 9/99


External Temperature

Time

Time at which temperature was recorded

Maximum Temperature since midnight (HI) Minimum temperature since midnight (LO) vdN 9/99

3


Operation of veltamat 3D in position

"Day Off" Heating From 6:00 to 23:00

You can change the temperature for one or several days on a temporary basis, for example for your day at home or for a holiday. (At the end of the period when you wish to cancel this setting press the button and hold for three seconds).

The buttons are under the left hand cover.

4

Press once for every day with normal operation or.... Press once for every day with short periods of temperature reduction.

vdN 9/99


Operation with veltamat 3D in position

"Holiday" A period with reduced heating temperatures.

Mode

Setting Temperature for reduced heating Or heating change

Duration (d = Days) vdN 9/99

5


Operation with veltamat 3D in position

"Relaxation"

You can change the temperature for one or several hours on a temporary basis - for example whilst you are at home or if you go out. (To cancel this special time period before it ends, press button 3 for 3 seconds)

Press once for each hour with increased heating or... Press once for each hour of reduced heating

6

Press the plus or Minus Button to change the initial works setting

vdN 9/99


Operation with veltamat 3D in position

"Absence"

At this time normal operation will be resumed

Duration (h = hours)

vdN 9/99

Temperature for relaxing at home or whilst away

Mode indicator 7


Setting the clock Open the lid and press the button for three seconds. The minutes flash.

Hours Year

Minutes Month, Day

Adjust the minutes with the

or

Press the button to set the hours. Set the hours. Repeat the procedure to set the year and the date.

VELTA, The Underfloor Heating Company. Unit 1B Denby Dale Industrial Park, Wakefield Road, Denby Dale, Huddersfield, HD8 8QH· Tel. +44 1484 860 811 · Fax +44 1484 865 775 · E-Mail info@u-h-c.co.uk http://www.u-h-c.co.uk

5000695

12/03/2001

Finally press this button for 3 seconds