Plot 2

Page 1

floor span

0.5000

100mm stub stack

floor span

1.7009

A 1.0000

100mm s.v.p.

1.0000

1.000

0.4000

0.930

Utility

gas fired balanced flue condensing boiler

external ground box for gas meter

Osma manhole

block walls min: 7kgm2 taken to foundation

Study

up

0.4000

Vertical Steel Colomn to support Steel UB in roof

1.0000

Hall

0.4000

2.450

5.1811

Osma manhole

En-suite shower

1.0000

1.975 walk in

2.000

0.4000

450x450x100w x 150deep insitu mass concrete padstone

19.560

heat detector

steel UB

floor span

B

Slate wall covering feature. (Double Height)

steel UB

1.8000

Dining

100mm s.v.p.

floor span

dwalf wall under to carry floor beams

steel UB 7.870

Living

100mm stub stack r.w.p

steel UB

water main entry

Kitchen block walls min: 7kgm2 taken to foundation

electric meter box

2.8106

steel UB

B Client

1.8000

1

2

3

1. This drawing must not be scaled, work to figured dimensions only 2. Dimensions must be verified on site before work is put in hand. 3. All building works to comply with current Building Regulations and British Standards. 4. Any discrepancies must be notified immediately.

0

steel UB

steel UB

dotted line indicates trench fill concrete foundation, depth to suit Building Control Officer

All ground floor doors are 840mm wide

r.w.p

Scale 1:50

Date

August 2008

Drawing Number

NA06-08

e-mail tony.walton4@ntlworld.com

The Old Warehouse, Waterside, Ely, Cambridgeshire. CB7 4AZ. tel 01353 616426

Proposed Ground Floor Plan PLOT 2

Drawing Title

Development at 10 Upherds Lane, Ely.

Project

Mr N. Naggarwal

0.3000

TONY WALTON DESIGN

5.600

0.5186 1.5000

r.w.pipe connect to 100mm drain point and run to soakaway min: 5m from building

100mm s.v.p.

1.0000

9.160

1.2500

0.3000

3.725

r.w.p 0.6558 0.4000

1.220

1.1381 1.5000 1.1381

0.3000

1.8000

0.450

1.8000

1.250

Bedroom

2.5322

2.530

A

0.9500 0.3988

0.3745 0.430 0.5000 1.0000 0.400

new 100mm foul water connection to sewer & neighbouring new dwelling fall max: 1:70

6.4761


glass juliet balconys balcony guard 1100mm high

Bedroom

7.4320

A

100mm s.v.p.

S.A

En-suite

void

5.6106

down

Bedroom

6.5931 Vertical Steel Colomn to support Steel UB in roof

Hall 1.8025

B

3.2765

void

0.5186

4.5831

2.5688

Bedroom

glass juliet balconys balcony guard 1100mm high

1.7143

En-suite

walk in shower

50x220mm floor joists at 400mm c/c

1.5000

1.0000

2.0512 1.2125

all internal partitions to be timber studs with 12.5mm plasterboarded, min: density 10kgm2 with skim finish, insulated with mineral wool min: density 10kgm3

1.9000

Dressing

50x220mm floor joists at 400mm c/c 6.8890

2.2933

walk in shower

0.4000

100mm s.v.p.

Client

1

2

3

1. This drawing must not be scaled, work to figured dimensions only 2. Dimensions must be verified on site before work is put in hand. 3. All building works to comply with current Building Regulations and British Standards. 4. Any discrepancies must be notified immediately.

0

All ground floor doors are 840mm wide

glass juliet balconys balcony guard 1100mm high

Date

Scale 1:50

August 2008

Drawing Number

Project

Drawing Title

e-mail tony.walton4@ntlworld.com

The Old Warehouse, Waterside, Ely, Cambridgeshire. CB7 4AZ. tel 01353 616426

NA07-08

TONY WALTON DESIGN

Proposed First Floor Plan PLOT 2

Development at 10 Upherds Lane, Ely.

Mr N. Naggarwal

2.8210

1.8000

0.4012

1.8000

1.3205

3.6972 1.2000 Slate wall covering feature. (Double Height)

B

2.0757

3.1762 100mm s.v.p.

En-suite

3.4558

2.3354

A

1.3488

0.5000 1.8254


roof tile on 25x50mm trated timber battens on breathable membrane on 50x200 rafters fixed to U.B ridge, at max: 600mm c/c

150mm Celotex in rafter slope, min: 25mm air gap over, with a 500 gauge vapour barrier under rafters 12.5mm plasterboarded ceiling with skim finish

metal gutters, fascias and soffits

22mm floor grade chipboard flooring on 50x220mm fllor joists at 400mm c/c with 100mm mineral wool in floor void min: density 10kgm3

Study

Bedroom

2 0°

65mm reinforced floor screed on 120mm Celotex floor insulation on 1200 gauge dpm on concrete suspended beam and block floor, min: 250mm void below ventilated as manufacturers requirements, conditional approval required.

trench fill concrete foundation

0.6000

2.100

0.6000

2.4000

Dressing

Hall

2.675 0.6000

First Floor exterior to be clad in timber on 25x50 treated timber battens on breathable membrane

Client

1

2

3

1. This drawing must not be scaled, work to figured dimensions only 2. Dimensions must be verified on site before work is put in hand. 3. All building works to comply with current Building Regulations and British Standards. 4. Any discrepancies must be notified immediately.

0

Standard Notes All groundConstruction floor doors are 840mm wide Cavity wall construction:- 100mm facing brick,95mm cavity with full fill dritherm insulation, 100mm inner block, plaster and skim finish

Catnic CN7 steel lintels or similar are required over all openings in external wall, min: 150mm bearing each side, plaster inner face.

Gangnail roof trusses to have 100mmx 19mm timber bracing from eaves to apex, double nailed at each truss all to B.S 5268

Triple floor joists are required under all first floor timber partitions Double floor joists under baths

Timber struting is required where floor joist span exceeds 2.5m

Lateral restraint straps 30x 5x900mm long galvanised m.s are required at rafter and ceiling tie level and to floor joists parallel to walls, all spaced at 2m centres with solid timber noggins at strap position

Wall ties to B.S1243 spaced 900mm horizontially and 450mm vertically and 300mm at unbonded jambs to be 225mm stainless steel

Vertical damp proof courses are required adjacent to all openings in external wall,where cavity is closed

Cavity closings to have Dampcor insulated D.P.M inserted between brick and blockwork

Max: of 100mm between balusters, handrails min:900mm high and guarding to landings designed to resist horizontial force of 0.36Knm All as Approved Doc K

Staircases:- min going 240mm max rise 210mm max pitch 42o, min: width 850mm

Mains operated self contained smoke alarms to B.S5446 are required on each floor interconected to operate each unit on detection,battery backup required. alarms should be wired to a separate fused circuit, all as I.E.E regulations Above ground drainage to B.S 5572 and B.S 8000 with wastes in the following sizes:- basin 32mm, bath, shower and sink 40mm all with 75mm deep seal traps, shower traps to be accessable Below ground drainage to B.S 8301 and B.S 8000 as Osmadrain or similar bedded and surrounded in pea gravel, where drains pass thro walls concrete lintels are required to carry brickwork over

All windows to have sealed unit double glazing and in critical locations to comply with Approved Document Part N with laminated or toughened glass to B.S 6262

All glazing to doors and side lights within 1500mm of floor level and windows within 800mm of floor level to be safety glass as B.S 6206

Dwelling to be provided with a total 'equivalent ventilator area' of 70,000mm2

Ventilation kitchens at 60lts/sec bathrooms, utility rooms at 30lts/sec shall be mechanically ventilated.

Soakaways sited min: 5m from building

Insuation for hot water services as B.S 1566 and 5422, space heating to B.S 5449 All parts of construction to conform to Part M 2004, ramped access, doors, light switches etc, access for disable

Electrical switches etc to be positioned between 450-1200mm from floor level

The following elemental U-values to be achieved Roof 0.16 w/m2k Walls 0.30 w/m2k Floors 0.22 w/m2k Windows and rooflights 1.8 w/m2k

At least 6 new light fittings must be of a type only capable of receiving high efficacy lamps such as fluorescent tubes

SEDBUK efficiencies and commissioning certificates required before completion

Floor joists supported on metal joist hangers require lateral restraint straps at max: 2m centres

Space heating controls and HWS, Commissioning of heating and HWS systems, Operating and Maintenance instructions for heating and hot water systems all in accordance with Approved Document Part L

Electrical:- to conform to Part P installed by registered contractor, commissioning certificates required on completion

Any external lighting shall comply to requirements of Part L, automatically extinguishing when enough daylight, and only be used with lamps an efficacy greater than 40 lumens per circuit watt

TER (target emission rate) and initial proposed DER (dwelling emission rate) demonstrating the design air permeability as specified in Approved Document L1A section1. Provide the final calculation of the DER to reflect any changes in performance between design and construction and to demonstrate that the building as constructed meets the TER. Copies of results of the air permeability tests of dwelling required.

August 2008

Date

Scale 1:50

Project

Drawing Number

Mr N. Naggarwal Drawing Title

Development at 10 Upherds Lane, Ely.

NA08-01

e-mail tony.walton4@ntlworld.com

The Old Warehouse, Waterside, Ely, Cambridgeshire. CB7 4AZ. tel 01353 616426

Cross Section A - A

TONY WALTON DESIGN


South

North

glass juliet balconys

West

East

Rev A 27.06.08 Various revisions Client

1

2

3

4

5

6

SCALE

Notes 1. This drawing must not be scaled, worktofigureddimensionsonly 2. Dimensions must be verified on site beforeworkisput inhand. 3. All building works to comply with current BuildingRegulationsandBritishStandards. 4. Any discrepancies must be notifiedimmediately.

0

natural slate roof

Scale 1:100

June 2008

Date

Mr N.Aggarwal Project

The Old Warehouse, Waterside, Ely, Cambridgeshire. CB74AZ. tel 01353616426 e-mail tony.walton4@ntlworld.com

NA09-08A

Drawing Number

Development at 10 Upherds Lane, Ely.

Drawing Title

Proposed Elevations Plot 2

TONY WALTON DESIGN