Thermostat wiring options Individually connected
Daisy chain connected. T145
T146 / T148
DRAIN
A B
optional controller link for more than one controller
Electrical Schematic
T143 A B-
+ -
Smatrix Pulse Base with FLUVIA 15 (Wired) Ref: SPB-1.0A
OR A B+ -
A B+ -
Uponor reserve the right to alter specifications and operating parameters for all their systems at any time as part of their policy of continuous product development.
A B+ -
connection to controller (indiviual)
Connections to the controller can be made in any combination of daisy chain or individually. But you must connect:-
to to to to
A B+ -
A B + -
N
A B + -
connection to controller (Daisy Chain)
The bare drain wire must be earthed at one end only. N
L N E 230V Supply From 3 Amp Fused Spur
Connect to boiler demand. (refer to boiler manufacturer for details). OR OPTION: If using multiple boxes use boiler relay on master controller.
RJ-45 supplied cable
A B+ -
A B-
A B + - Upto 6 additional
zones
RELAY 1 (PUMP)
RELAY 2 (Boiler)
OK
a 1 b
Transformer
a 2 b
3
4
5
7
6
Base Controller (X-245) Upto 8 x 24V Uponor actuators (only one actuator per terminal).
Slave Module Unit (M-242) Plugs into the end of the base module .
8
9
10
11 12
Upto 6 additional 24V Uponor actuators (only one actuator per terminal).