val-antica-ca-water-treatment

Page 1

Mag

w a t e r i n t e r n a t i o n a l www.val-water.com w w w . v a l v o d a . s i

H a r d w a t e r a n d A n t i c a C a + + S o l u t i o n s

Slovak Republik w w w . e u v a n t i c a . c o m w w w . w a t e r s c a l e . e u

V e r . 1 . 0


E u r o p e a n a n d w o r l d w i d e p a r t n e r s h i p h a r d W a t e r T r e a t m e n t , w a t e r s c a l e s o l u t i o n s , w a t e r i o n i s a t i o n , w a t e r c l e a n i n g a n d f i l t e r i n g e c o l o g i c a l a n d h e a l t h c a r e a r e a s a n d p r o j e c t s

www.val-water.com w w w . v a l v o d a . s i

Systhema d.o.o. Volčja Draga 100 Slovenija - Europe Union

P r o j e c t c o p y r i g h t s , m a n a g e m e n t , e n g i n e e r i n g a n d g e n e r a l c o n t a c t s A n d r e j K e b e r B E (Bachelor of Engineering) Mobile: +386 (0)41 719 321 +386 (0)40 - 746 259 Phone: +386 (0)5 - 993 23 52

Mail: FB:

info@val-voda.si info@val-water.com www.facebook.com/andrej.keber

T e c h n i c a l a r e a s , d e v e l o p m e n t a n d t e c h n i c a l s u p p o r t Jože Romšak s.p. Phone: +386 (0)1 832 50 27 Črna pri Kamniku 12 1242 Stahovica Slovenia - Europe Union

Mobile: +386 (0)41 789143 Mail: superval.joze@gmail.com

Contact person: J o že R o m ša k

O r g a n i s a t i o n , m a n a g e m e n t a n d e d i t o r i a l o n e c o l o g y , w a t e r a r e a s & h e a l t h c a r e M S c . L i d i j a K o c u v a n G a šp e r i č M o b i l e : + 3 8 6 ( 0 ) 4 0 7 4 0 9 9 7 M a i l : l i . k o c u v a n @ g m a i l . c o m F a c e B o o k : w w w . f a c e b o o k . c o m / l i . k o c u v a n

P o w e l A n t i c a s . r . o . Phone: +421 907 201 499 L e v o c s k a 2 Fax: +421 51 7711 195 0 8 0 0 1 P r e s o v Mobile: +421 907 201 499 S l o v a k i a Contact person: I n g . S t e f a n i a K u l k o v a I n t e r n a t i o n a l S a l e s D e p a r t m e n t


W a t e r t r e a t m e n t , e c o l o g y , a w a r e n e s s

w a t e r i n t e r n a t i o n a l Wealth of Health

www.bogastvozdravja.si





PRINCIPLE OF FUNCTION - DEVICES AntiCa++ (PHYSICAL WATER TREATMENT)

ic

- coil current

ip La - active length

- piping current

ELECTRONIC SCALE CONTROL UNIT

POWEL

ANTICA

Ca++

Fig.A

R

Ca++

DESCALING

AntiCa++ DEVICE POWER

Fig.B

BEFORE TREATMENT

AFTER TREATMENT

ic 32

Ca 2+(HCO )

v

HCO3

>

2 agr

c(CO2)

=

+

-

+ CaCO3

DN CaCO3

H 2O CO2

e

ip ion power

La

ip

>

HCO3-

Ca++ -

H2O + (CO )

e

c [mmol/l] pH

G3. Constitutional diagram of water 12

Consideration

11 Before treatment: μ1 = μr or μ1 > μr

10 9

2+

Ca - accumulated surplus: Δ Ca = 1 / 3 ( μ1 - μr )

8 7 6 5 pH

4

y( e )

3

y( r )

2

c( Ca 2+ )

After treatment with AntiCa++ device: μ2 < μr liberated CO2 agr concentration c( CO2 )agr = 1 / 3 ( μr - μ2 )

μr - equilibrium point

μ1 - actual ion power

1

c(HCO3 -)

0 0 0,04 0,2 0,36 0,52 0,68 0,84 1μ 1,16 1,32 1,48 1,64

μ2 - zone of action AntiCa++ device

m ion power

The graph of the equilibrium curve y( r ), 2+ evolutional line y( e ), pH, c( Ca ) and c(HCO3 ) curve is generated by AntiCa++ software.



I M P O R T A N T C o m p a r i s o n o f A n t i C a + + t o w a t e r t r e a t e m e n t d e v i c e s t h a t w o r k o n t h e g a l v a n i c p r i n c i p l e : F e a t u r e s o f d e v i c e s t h a t w o r k o n t h e g a l v a n i c p r i n c i p l e : 1 . i t d i s s o l v e s z i n c i n t o t h e w a t e r w h i c h i s a . h e a v y m e t a l 2 . t h e e f f e c t o f t h e t r e a t m e n t i s l o s t a f t e r c e r t a i n d i s t a n c e b e h i n d t h e p l a c e o f i n s t a l l a t i o n , 3 . t h e o p e r a t i n g l i f e i s 1 0 t o 1 5 y e a r s b e c a u s e t h e z i n c a n o d e m e l t s ( t h i s d e p e n d s o n t h e w a t e r a m o u n t a n d c o m p o s i t i o n ) 4 . c o m p l i c a t e d a n d c o s t l y i n s t a l l a t i o n : d u r i n g t h e i n s t a l l a t i o n t h e p i p e h a s t o b e i n t e r u p t e d , i t i s n e e d e d t o u s e o t h e r v a l v e s f o r c l o s i n g t h e w a t e r , n e w h i g h q u a l i t y a n d t i g h t l y i n s t a l l e d j o i n t , i n s t a l l a t i o n o f b y p a s s s o t h a t t h e w a t e r d o e s n o t s t o p 5 . t h e d e v i c e s m u s t b e c l e a n e d r e g u l a r l y w h i c h r e q u i r e s a l o t o f m a n u p u l a t i o n s , 6 . t h e d e v i c e s c a u s e s t h e b a r r i e r i n s i d e t h e w a t e r p i p e s a n d c a n c a u s e t h e p r e s s u r e l o s t o r c a n c o l l e c t a n y d i r t p a r t i c l e s .

E l e c t r o n i c W a t e r T r e a t m e n t A n t i C a + + 1 . A n t i C a + + i s n o t i n c o n t a c t w i t h d r i n k i n g w a t e r t h e r e f o r e i t d o e s ( n o h e a v y m e t a l s o r n o t d i s s o l v e a n y t h i n g i n w a t e r o t h e r d a n g e r o u s e l e m e n t s ) 2 . t h e e f f e c t o f t r e a t m e n t i s n o t l o s t A n t i C a + + p r o t e c t s a s h p i p e l i n e o f t h e l e n g h t o f 4 k m i n K o s i c e h e a t i n g s t a t i o n 3 . t h e o p e r a t i n g l i f e i s a t l e a s t 2 0 y e a r s , 4 . i n s t a l l a t i o n i s s i m p l e a n d c h e a p n o p i p e i n t e r u p t i o n n o r n e e d f o r n e w v a l v e s n o r b y p a s s , 5 . n o n e e d f o r m a i n t e n a n c e o f t h e d e v i c e , l o w p o w e r c o n s u m p t i o n ( 1 1 0 W d e p e n d i n g o n t h e t y p e o f A n t i C a + + ) 6 . n o b a r r i e r p u t i n t o t h e p i p e s .


Powel Antica Ltd. Levocska 2

www.waterscale.eu

080 01 Presov

www.euvantica.com

Slovakia Tel: +421 907 201 499, Fax: +421 51 77 11 195 Email: kulka@waterscale.eu, kulka@euvantica.com

Protection and prevention against the water scale PRICE LIST OF DEVICES AntiCa++ FOR WATER TREATMENT

AntiCa++ Compact

Features of AntiCa++ Compact › ideal for home appliances (for pipe of diameter of 3/8 inch) › installation in front of:

›boilers ›washing machines ›dishwashers ›other expensive household machines › small and compact › for all materials of pipe › easilly mounted directly on the pipe › protects home appliances from hard lime scale deposits and thus saves money › result of 18 years of experience with hard water treatment We quarantee quality, reliability and function!

We understand water...


EUV DOM

ELECTRONIC SCALE CONTROL UNIT N! OLD ! UTIO SEH CAOR HOU

LY ON

Devices EUV 15 DOM - 65 DOM

Ca++

F

Ca++

DESCALING

They are designed for simple applications, if the flow rate is within the limits given in the table 2. In the case, when the flow rate is at the lower limit and any other circumstances do not prevent it, it is recommended to reduce piping diameter in he t place of installation and use the device, which is smaller by one order. These devices are suitable for households.

R

METAL PLASTIC

Table 2 Type of the device

Optimum flow rate (m3/h) 0,1 - 0,3 0,2 - 0,6 0,3 - 0,9 0,4 - 1,4 0,8 - 2,3 1,2 - 3,5 2,0 - 6,0

EUV 15 DOM EUV 20 DOM EUV 25 DOM EUV 32 DOM EUV 40 DOM EUV 50 DOM EUV 65 DOM

Internal diameter of piping (mm-inch) 15 (1/2") 20 (3/4") 25 (1") 32 (5/4") 40 (6/4") 50 (2") 65 (2 1/2")

Dimensions (WxHxD mm) 110 x 70 x 55 110 x 70 x 55 110 x 70 x 55 160 x 96 x 61 160 x 96 x 61 160 x 96 x 61 160 x 96 x 61

DN

Nx

SPECIFICATIONS: Supply voltage: Consumption: Working period: Working temp.: Weight:

230 V, 50 Hz (US model 110 V, 60 Hz) EUV 15 - 25 DOM - 2 VA EUV 32 - 65 DOM - 6 VA min. 20 years 0o C to 40o C EUV 15 - 25 DOM - 0,5 kg EUV 32 - 65 DOM - 1,0 kg

Nx

min. 3 x DN

Table 1 Total hardness ( o dH) < 16 16 - 24 24 - 32 32 - 40 > 40 Num. of coils N + N 11 + 11 12 + 12 13 + 13 14 + 14 15 + 15 1 odH <=> 0,18 mmol / l <=> 0,36 mval / l <=> 17,8 ppm <=> 1,78 o f

PO

W EL

ANTICA

ELECTRONIC SCALE CONTROL UNIT

EUV D

Ca++

Devices EUV 10 D - 65 D They are designed for simple applications, if the flow rate is within the limits given in the table 2. In the case, when the flow rate is at the lower limit and any other circumstances do not prevent it, it is recommended to reduce piping diameter in the place of installation and use the device, which is smaller by one order. These devices are suitable for sm all plants, such as: - laundries - bakeries - small compressor rooms - hairdresser´s and the like Table 2 Type of the device EUV 10 D EUV 15 D EUV 20 D EUV 25 D EUV 32 D EUV 40 D EUV 50 D EUV 65 D

Optimum flow rate (m3/h) 0,10 - 0,45 0,30 - 1,00 0,60 - 1,80 0,90 - 2,70 1,40 - 4,40 2,30 - 6,80 3,50 - 10,50 6,00 - 18,00

min. 3 x DN

200 mm

Internal diameter of piping (mm-inch) 10 (3/8") 15 (1/2") 20 (3/4") 25 (1") 32 (5/4") 40 (6/4") 50 (2") 65 (2 1/2")

R

Ca++

DESCALING

POWER

METAL

PLASTIC

DN

Dimensions (WxHxD mm) 160 x 96 x 61 160 x 96 x 61 160 x 96 x 61 160 x 96 x 61 160 x 96 x 61 160 x 96 x 61 160 x 96 x 61 215 x 130 x 77

Nx

min. 3 x DN

Nx

200 mm

min. 3 x DN

SPECIFICATIONS: Supply voltage: Consumption: Working period: Working temp.: Weight:

230 V, 50 Hz (US model 110 V, 60 Hz) EUV 10 - 65 D - 6 VA min. 20 years 0o C to 40 o C EUV 10 - 50 D - 1,0 kg EUV 65 D - 2,5 kg Signalling contacts: EUV 65 D only max 15 W, max 1 A, max 125 V

Table 1 Total hardness ( o dH) < 16 16 - 24 24 - 32 32 - 40 > 40 Num. of coils N + N 11 + 11 12 + 12 13 + 13 14 + 14 15 + 15 1 odH <=> 0,18 mmol / l <=> 0,36 mval / l <=> 17,8 ppm <=> 1,78 o f


2001.09.06

13:55 Logik

PRG

EUV T

OK

1

R

2

DESCALING

POWEL

ANTICA

ELECTRONICSCALE ELECTRONIC SCALECONTROL ELIMINATOR UNIT

CCaa++

0

0

R

++

POWER

EUV 32 T - 65 T devices They are designed for applications , where it is necessary to change treating signal performance in dependence of variable flow rate. The treating signal can be changed in two levels. These devices are supplied with switch timer and are suitable for: - small industrial plants - hotels, motels, - heat exchanger stations

METAL

PLASTIC

Table 2

Type of the device

Optimum flow rate (m3/h) I. 0,40 - 1,40 II. 1,40 - 4,40 I. 0,80 - 2,30 II. 2,30 - 6,80 I. 1,20 - 3,50 II. 3,50 - 10,50 I. 2,00 - 6,00 II. 6,00 - 18,00

EUV 32 T EUV 40 T EUV 50 T EUV 65 T

Internal diameter of piping (mm-inch) 32 (5/4")

Dimensions (WxHxD mm) 215 x 130 x 77

40 (6/4")

215 x 130 x 77

50 (2")

215 x 130 x 77

65 (2 1/2")

215 x 130 x 77

DN

Nx

SPECIFICATIONS: Supply voltage: 230 V, 50 Hz (US model 110 V, 60 Hz) Consumption: EUV 32 - 65 T - 6 VA Working cycle: daily or weekly Working period: min. 20 years Working temp.: 0 o C to 40 oC Weight: EUV 32 - 65 T - 2,5 kg Signalling contacts: max 15 W, max 1 A, max 125 V

Nx

min. 3 x DN

min. 3 x DN

200 mm

Table 1 Total hardness ( o dH) < 16 16 - 24 24 - 32 32 - 40 > 40 Num. of coils N + N 11 + 11 12 + 12 13 + 13 14 + 14 15 + 15 1 odH <=> 0,18 mmol / l <=> 0,36 mval / l <=> 17,8 ppm <=> 1,78 o f

EUV MI Table 1

Luca

TYPE OF DEVICE

+

+ POWE

200 200 250 250 300 300 500 500 800 800 800

L

ANTICA

ELECTRONIC SCALE CONTROL UNIT LEVEL

++ Ca Ca++ .

R

6

DESCALING

R POWER

+

EUV 50 MI EUV 65 MI EUV 80 MI EUV 100 MI EUV 125 MI EUV 150 MI EUV 200 MI EUV 250 MI EUV 300 MI EUV 400 MI EUV 500 MI

L (mm)

EUV 50 MI - 500 MI devices

+

T h e s e d e v i c e s a r e m o s t p o p u l a r d e s i g n e d f o r a p p l i c a t i o n s , w h e r e t h e w a t e r f l o w c h a n g e s i n g r e a t v a l u e s . T r e a t i n g s i g n a l c a n b e a d j u s t e d i n 9 l e v e l s m a n u a l l y b y s w i t c h i n g k n o b i n a c c o r d a n c e o f t h e f l o w r a t e . E a c h u n i t i s e q u i p p e d w i t h a t a b l e w i t h s p e c i f i e d w a t e r f l o w a n d t r e a t i n g s i g n a l l e v e l . Typical use: Industrial applications Table 2 Type of the device EUV 50 MI EUV 65 MI EUV 80 MI EUV 100 MI EUV 125 MI EUV 150 MI EUV 200 MI EUV 250 MI EUV 300 MI EUV 400 MI EUV 500 MI

Optimum flow rate (m3/h) 0,20 - 11 (16)* 0,30 - 18 (26)* 0,50 - 27 (40)* 0,80 - 42 (62)* 1,40 - 66 (100)* 2,00 - 100 (140)* 3,20 - 170 (250)* 6,00 - 270 (400)* 8,00 - 380 (560)* 13,00 - 680 (1000)* 24,00 - 1100 (1600)*

Internal diameter of piping (mm-inch) 50 (2") 65 (2 1/2") 80 (3") 100 (4") 125 (5") 150 (6") 200 (8") 250 (10") 300 (12") 400 (16") 500 (20")

Dimensions (WxHxD mm) 275 x 220 x 140 275 x 220 x 140 275 x 220 x 140 275 x 220 x 140 275 x 220 x 140 275 x 220 x 140 275 x 220 x 140 275 x 220 x 140 275 x 220 x 140 275 x 370 x 140 275 x 370 x 140

DN

11 x

11 x

SPECIFICATIONS: Supply voltage: Consumption:

230 V, 50 Hz (US model 110 V, 60 Hz) EUV 50 - 300 MI - 10 VA EUV 400 - 500 MI - 16 VA Working period: min. 20 years Working temp.: 0o C to 40o C Weight: 4 to 6 kg Signalling contacts: max 15 W, max 1 A, max 125 V

min. 3 x DN

L

min. 3 x DN


EUV TI Luca +

Table 1

+ PO

TYPE OF DEVICE

2001.09.06

L (mm)

L

13:55

ELECTRONIC SCALE CONTROL UNIT LEVEL

Logik

200 200 250 250 300 300 500 500 800 800 800

PRG

OK

1

R

2

++ Ca Ca++ .

68

R

DESCALING

R POWER

+

EUV 50 TI EUV 65 TI EUV 80 TI EUV 100 TI EUV 125 TI EUV 150 TI EUV 200 TI EUV 250 TI EUV 300 TI EUV 400 TI EUV 500 TI

WE

ANTICA

+

EUV 50TI - 500 TI devices These devices are designed for similar applications like types EUV MI. The 9 levels can be still devided in two time zones. (The setting is independent in both zones in the extent as for MI). Typical use: industrial applications. Table 2 Type of the device

Optimum flow rate (m3/h) 0,20 - 11 (16)* 0,30 - 18 (26)* 0,50 - 27 (40)* 0,80 - 42 (62)* 1,40 - 66 (100)* 2,00 - 100 (140)* 3,20 - 170 (250)* 6,00 - 270 (400)* 8,00 - 380 (560)* 13,00 - 680 (1000)* 24,00 - 1100 (1600)*

EUV 50 TI EUV 65 TI EUV 80 TI EUV 100 TI EUV 125 TI EUV 150 TI EUV 200 TI EUV 250 TI EUV 300 TI EUV 400 TI EUV 500 TI

Internal diameter of piping (mm-inch) 50 (2") 65 (2 1/2") 80 (3") 100 (4") 125 (5") 150 (6") 200 (8") 250 (10") 300 (12") 400 (16") 500 (20")

Dimensions (WxHxD mm) 275 x 220 x 140 275 x 220 x 140 275 x 220 x 140 275 x 220 x 140 275 x 220 x 140 275 x 220 x 140 275 x 220 x 140 275 x 220 x 140 275 x 220 x 140 275 x 370 x 140 275 x 370 x 140

DN

11 x

SPECIFICATIONS: 230 V, 50 Hz (US model 110 V, 60 Hz) EUV 50 - 300 TI - 10 VA EUV 400 - 500 TI - 16 VA Working cycle: daily or weekly Working temp.: 0o C to 40 o C Weight: 4 to 6 kg Signalling contacts: max 15 W, max 1 A, max 125 V

11 x

Supply voltage: Consumption:

L

min. 3 x DN

min. 3 x DN

EUV AI Table 1

Luca

TYPE OF DEVICE

+

+ POW

200 200 250 250 300 300 500 500 800 800 800

ELECTRONIC SCALE CONTROL UNIT

EL

ANTICA

A

M LEVEL

0

++ Ca Ca++ .

R

8

DESCALING

R POWER

+

EUV 50 AI EUV 65 AI EUV 80 AI EUV 100 AI EUV 125 AI EUV 150 AI EUV 200 AI EUV 250 AI EUV 300 AI EUV 400 AI EUV 500 AI

L (mm)

+

EUV 50 AI - 500 AI devices These devices are designed for the same applications like types EUV MI. The treating signal is adjusted automatically according real flow rate . The devicebe must connectedot a flowmeter , which is equi pped with asensor, which gives information about flowate r to device´s cont rol unit. (The flowmeter and sens or must be ordered separately, as they are not supplied with the device) Typical use: large water treatment plants, boiler rooms, t exchangers hea etc.

Table 2

Type of the device EUV 50 AI EUV 65 AI EUV 80 AI EUV 100 AI EUV 125 AI EUV 150 AI EUV 200 AI EUV 250 AI EUV 300 AI EUV 400 AI EUV 500 AI

Optimum flow rate (m3/h) 0,20 - 11 (16)* 0,30 - 18 (26)* 0,50 - 27 (40)* 0,80 - 42 (62)* 1,40 - 66 (100)* 2,00 - 100 (140)* 3,20 - 170 (250)* 6,00 - 270 (400)* 8,00 - 380 (560)* 13,00 - 680 (1000)* 24,00 - 1100 (1600)*

Internal diameter of piping (mm-inch) 50 (2") 65 (2 1/2") 80 (3") 100 (4") 125 (5") 150 (6") 200 (8") 250 (10") 300 (12") 400 (16") 500 (20")

Dimensions (WxHxD mm) 275 x 220 x 140 275 x 220 x 140 275 x 220 x 140 275 x 220 x 140 275 x 220 x 140 275 x 220 x 140 275 x 220 x 140 275 x 220 x 140 275 x 220 x 140 275 x 370 x 140 275 x 370 x 140

OPTO SENSOR

SPECIFICATIONS: Supply voltage:

230 V, 50 Hz (US model 110 V, 60 Hz) Consumption: EUV 50 - 300 AI - 10 VA EUV 400 - 500 AI - 16 VA Imp. contr. signal: 1 l/1imp., 10 l/1imp. Working temp.: 0 oC to 40 o C Weight: 4 to 6 kg Signalling contacts: max 15 W, max 1 A, max 125 V

DN

11 x

11 x

000 394

FLOWMETER

min. 3 x DN

L

min. 3 x DN




w a t e r i n t e r n a t i o n a l

































Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.