Akyver Glazing in Multi-Wall Polycarbonate

Page 1

Akyver

Glazing in Multi-Wall Polycarbonate

information Technical

www.kaysersberg-plastics.com


2

Technical information Generalities

Akyver®

Akyver Confort® Plus

Akyver Dropless®

fig.2

fig.3

Panel untreated Dropless®

Panel treated Dropless®

Product range.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Fire classification.. . . . . . . . . . . . . . . . . . . . . . . . . . 7

Storage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Applications.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Conversion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 C u t t i n g - S h a p i n g .. . . . . . . . . . . . . . . . . . . . . . 8 C l e a n i n g .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Drilling................................. 8 W a t e r r e s i s t a n c e .. . . . . . . . . . . . . . . . . . . . . 8

Cleaning.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

fig.1

The light is reflected, causing a considerable reduction in Light Transmission.

The light is refracted, causing only a very slight loss of Light Transmission.

Summary

Range of products Akyver®. . . . . . . . . . . . . 4 Specifications Akyver®.. . . . . . . . . . . . . . . . . . . 5 D i m e n s i o n a l .. . . . . . . . . . . . . . . . . . . . . . . . . . . 5 T h e r m a l .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Acoustic................................6 Mechanical.............................6 O p t i c a l .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Suitable profiles for Akyver® sheets.. . . . . . . . . . . . . . . . . . . . . . . 8 L i n k i n g p r o f i l e s .. . . . . . . . . . . . . . . . . . . . . . 9 Preparation and sealing of polycarbonate sheets.. . . . . . . . . . . . . . . . . 9 Our recommendations A d v e r s e e n v i r o n m e n t s . . . . . . . . . . . . . 10 F i n i s h i n g p r o f i l e . . . . . . . . . . . . . . . . . . . . 10 W a t e r p r o o f s e a l .. . . . . . . . . . . . . . . . . . . . 10

Fitting instructions.. . . . . . . . . . . . . . . . . . . . . . 11 Joining Akyver® s h e e t s u s i n g p r o f i l e s . . . . . . . . . . . . . . 11 Fitting Akyver Sun Type® s h e e t s f o r r o o f i n g a n d c l a d d i n g . 12 F i t t i n g A k y v e r S u n   T y p e ®

sheets for Skylights (curved sheets) ....................

14

Profiles and accessories Akyver®. . . . 15

www.kaysersberg-plastics.com


Technical information Product Range

3

Akyver®

Akyver® is a light and impact resistant insulating polycarbonate glazing. The 4, 6, 8, 10 mm depth sheets are available in twin wall form, 10 mm in 4 walls, 16, 20 and 25 mm in 7 walls, 32 mm in 8 walls.

Akyver Sun Type® Thanks to their special antiultraviolet treatment by coextrusion, Akyver Sun Type® sheets are highly suitable for all outside applications. The homogeneity of the UV absorption layer provides: • a long term protection • very even distribution of anti-UV layer • a smooth surface • no risk of splintering when the sheets are bent.

This treatment ensures excellent weatherproofing as well as protection against yellowing and loss of strength over the years. The treated surface which is to be exposed to sunlight is covered by a blue printed film and marked with a band. Technical approval CSTB GS 6 (other countries on request) Test report N° GM/95-44 concerning bent sheets.

Guarantee Akyver Sun Type® offers a double guarantee for the sheets of min. 6 mm: Guarantee of properties (valid within the EEC) • 10 year full guarantee - loss of light transmission limited to 6% - increase of yellow index of the translucent sheets limited to 10% - stable mechanical properties • 5 year guarantee against hail This guarantee applies only to sheets which have not suffered harmful effects of extraneous chemicals. A noncomprehensive list of the compatible chemicals with polycarbonate can be provided on demand. This list may be updated without notice from time to time. For any enquiry please contact us.

Technical information Applications

Akyver®

Uses The Akyver® sheets have been specially designed for indoor use: false ceilings, partitions and panelling. The Akyver Sun Type® sheets with special anti-ultraviolet treatment are suitable for outdoor use: - glazing of industrial, sports or agricultural buildings - roofing - veranda covering - skylights vaults - cladding panels - glass roof constructions - shed roofs - greenhouses - conservatories. The Akyver Confort Plus® (fig. 1) sheets, besides their anti-ultraviolet treatment, are coextruded with a special coating on the outside which reduces the quantity of transmitted solar energy inside the glazed buil-

dings by decreasing the diffusion of the near infra-red rays. The Akyver Dropless® (fig. 2) sheets are coated on their internal surface, which reduces condensation and maintains the level of light transmission. They are recommended for verandas, greenhouses and swimming pool coverings. The Akyver Sign sheets are particularly suitable for advertising panels or signs.

Thickness According to Application Depending on use, we recommend the following thicknesses: • 4 mm: indoor panelling and ceilings • 4 and 6 mm Akyver Sign: Advertising panels or signs • 6 mm: greenhouses, skylights, shed roofs, cladding panels, outdoor panelling • 8 and 10 mm: shed roofs, cladding panels, skylights, partion panels • 16 and 25 mm: roofing, cladding panels, veranda covering • 32 mm: verandas

www.kaysersberg-plastics.com


4

Technical information Range of Products

Akyver®

Standard Formates For products available in stock and non-standard formats, please contact us.

Akyver®

Akyver Sun Type® (with anti-UV protection)

Thickness (mm)

4

4

6

8

10

Weight (g/sqm)

800

800

1 300

1 500

1 700

Length (mm)

6 000 7 000

6 000 7 000

6 000 7 000

6 000 7 000

6 000 7 000

2 100

2 100

2 100

2 100

2 100

Colour

Clear Clear

Clear Opal Bronze*

Clear Opal Bronze*

Clear Opal Bronze*

Akyver Sign White

2 100

No

No

Width (mm)

Thickness (mm)

No

2 100

Akyver Sun Type® 4  walls 10

Akyver Sun Type® 7 walls 16

20

8 walls  25

32 7mm

Weight (g/sqm)

1 750

2 600

2 900

3 400

Length (mm)

6 000 7 000

6 000 7 000

6 000 7 000

6 000 7 000

6 000 7 000

Width (mm) 1*050 2 100

980 * 1 050 * 1 200 * 2 100

1 050 * 2 100

1 050 * 2 100

1 220

Clear Opal Bronze*

Clear Opal Bronze*

Clear Opal Bronze*

2 100 1 050 **

2 100 1 050 **

2 100 1 050 **

Colour Clear Opal Bronze* 2 100 Confort Plus® Opal, Width (mm) 1 050 ** * Minimum order required. Please contact us. ** Open edges.

3 600

Clear Opal Bronze*

• Akyver 4 walls in 8 mm and 16 mm: minimum order required. • Special colours (green, blue): minimum order required.

www.kaysersberg-plastics.com


5

Technical information Specifications

Akyver®

Dimensional Thickness (mm) Thickness tolerance (mm) Width of sheet (mm)

4

6

8

10

10 4W

16 7W

20 7W

25 7W

32 8W

± 0,4

± 0,4

± 0,4

± 0,4

± 0,4

± 0,4

± 0,4

± 0,4

2100 ± 5 2100 ± 5 2100 ± 5 2100 ± 5 2100 ± 5

2100 ± 5

2100 ± 5

2100 ± 5

1220 ± 5

± 0,4

g/sqm

800

1300

1500

1700

1750

2600

2900

3400

3600

Distance between ribs (mm)

6,5

6,5

11

11

7

12

12

12

16

10 4W

16 7W

20 7W

25 7W

32 8W

Thermal •

Thermal conductivity of polycarbonate

λ = 0,20 W/m2°C •

Thermal insulation U value

Thickness (mm) 4 Uc (Rth 2000) (W/m2.°K) U (W/m2.°K)

6

8

10

3,5

3,2

3,0

2,5

1,8

1,6

1,5

1,2

Please contact us for further information or details. •

g factor total solar radiant heat energy transmitted (solar factor) according to EN410 mm

10 2W 10 2W 10 2W 10 4W 10 4W

16 7W

16 7W

16 7W

20 7W

20 7W

Clear

Opal

Confort +

Clear

Opal

Clear

Opal

Confort +

Clear

Opal

g

0,77

0,56

0,51

0,66

0,52

0,77

0,55

0,48

0,77

0,55

Thermal expansion: 0,07 mm/m°C

When fitting the sheets, please take into consideration an expansion space of 4 mm per linear metre in both directions. Expansion of the sheets may cause audible cracking sounds. •

Special product Akyver Confort Plus®

Akyver Confort Plus®, thanks to a new process, reduces the quantity of transmitted solar energy inside the glazed buildings by decreasing the diffusion of the near infrared rays. When the outside temperature is high, Akyver Confort Plus® can reach up to 25% temperature reduction compared to a standard Akyver sheet inside the building. Test CEBTP N° B 232-0-327 (08/2000) Energy transmission and solar factor obtained by the CEBTP (Building and Public works test centre) report n° B 232-0-327.

16 Seven 16 Seven

0


6

Technical information Specifications

Akyver®

Acoustic Index of acoustic attenuation as per NFS 31051 dB(A). Thickness (mm) Acoustic insulation

6

8

10

16

20

25

32

16

16

17

20

21

22

21

Mechanical Akyver® sheets can be cold-bent into a curved shape down to a minimum radius of curvature. Maximum usage temperature: 115°C, Minimum: - 40°C Thickness (mm)

4

6

8

10

10 4W

16 7W

20 7W

25 7W

Min Radius (mm)

600

900

1200

1500

1500

2400

3000

3750

Characteristics

Norm

Value-Units

Density

ISO 1183, ASTM D 792, DIN 53479

1.2 g/cm3

Yield stress Nominal tensile strain at break Tensile modulus Hardness on bead penetration H30 Coefficient of linear thermal expansion (23 à 80 °C)

ISO 527, ASTM D 638, DIN 53455 ISO 527, ASTM D 638, DIN 53455 ISO 527, ASTM D 638, DIN 53457 ISO 2039, DIN 53456

60 Mpa

Vicat softening temperature VST/B50 IZOD notched impact strength (23°) Impact resistance Charpy at 23° Water absorption Water vapour

> 50% 2300 Mpa 95 Mpa

DIN 53752

7.0 E-5°C-1

ISO 306, DIN 53460

145°C

ISO 180-4A, ASTM D 256A

> 50 KJ/m2

ISO 179-1eU, ASTM D 256B, DIN 53453 ISO 62, ASTM D 570, DIN 53495-1L DIN 53122-1 permeability (g/m2.24h.bar)

no break 0.35% approx. 15

Akyver Sun Type® sheets 8,10, 16, 20, 25 and 32 mm (pass) the German ball impact test as per DIN 18032.

www.kaysersberg-plastics.com


7

Technical information Specifications

Akyver®

Optical Light transmission coefficient (%) Thickness (mm)

10 4W 16 7W 20 7W 25 7W 32 8W

4

6

8

10

Clear

85

85

85

85

73

64

64

64

70

Opal

73

64

64

62

57

54

54

50

43

Bronze

50

44

44

42

29

22

50

45

Confort Plus® Opal

The direct light transmission values are measured with a lux-meter as per NF P38-511.

Light transmission U.V.: Ultra-Violet 136 to 400 nanometres V.: Visible 400 to 780 nanometres I.R.p.: Near Infra-Red 780 to 1,400 nanometres I.R.m.: Medium Infra-Red > 1,400 to 3,000 nanometres I.R.l.: Far Infra-Red: 3,000 to 1,000,000 nanometres This curve gives the global transmission values for an Akyver Sun Type® 6 mm sheet.

Fire classification

Akyver®

Akyver® - Akyver Sun Type® Thickness (mm) France NF P 92-501, 92-504, 92-505 Germany DIN 4102 European SBI- classification EN 13501 test report

4

6

8

10

10 4W

16 7W

20 7W

25 7W

M1

M1

M2

M2

M2

M2

M2

M2

B1

B1

B1

B1

B2

B2

B2

B2

/

B s1 d0

B s1 d0

B s1 d0

B s1 d0

B s1 d0

B s2 d0

B s2 d0

32 8W M2

B s2 d0

Akyver® sheets are by nature low flammability products. Please contact us for other countries regulations.

www.kaysersberg-plastics.com


8

Technical information Conversion

Akyver®

Cutting - Shaping

Cleaning

Water Resistance

Thin Akyver® and Akyver Sun Type® sheets may be cut with a sharp blade or a cutter. For other thicknesses, it is necessary to use a portable or fixed circular saw. The saw blades must be of high-speed steel or, preferably, steel with set-in tungsten carbide tips (80 teeth). For information, we recommend a circular saw with a minimum rotation speed of 3200 rpm (minimum linear speed of 48 m/s). The sheet must be fixed to the bench or wedged on the frame to avoid undesirable vibration.

We recommend the use of a compressed air nozzle (VENTURI type) with a minimum pressure of 6 bars (dry air).

The water resistance of the sheets is guaranteed by using aluminium profiles with neoprene joints. This water resistance can also be effected by using neutral mastics (list on demand). Before using silicone, make sure of its compatibility with polycarbonate. The closing of the flutes must be carried out by following the specifications of paragraph 8. The aluminium profile must also provide good ventilation inside the cells as well as adequate drainage.

Drilling Akyver® and Akyver Sun Type® sheets may be drilled at average speed with a sharp drill drill (drill at least 10 mm from the edge). Please take into consideration the expansion gap. Drilling diameter: D = screw diameter + 4 mm.

Suitable Profiles

Akyver®

DS SMITH KAYSERSBERG has developed a range of profiles for coverings and sheds made of Akyver Sun Type®.

Fitting principle: roofing, cladding panels 4

3

2

7

6

1: Bottom aluminium profile 2: Top aluminium profile (can be shaped) 3: Supporting bottom aluminium profile (can be shaped)

5

1

4: 5: 6: 7:

2

3

7

5

4

Side aluminium profile (only for 16 mm plates) Top aluminium profile - clip fixing Drainage base profile joint Watertight rubber joint

www.kaysersberg-plastics.com


9

Technical information Suitable Profiles

Akyver®

Linking Profiles •

Jointing profiles 1 and 2

Profile span 1 and 2

L in mm Load

These profiles, made up of 2 aluminium profiles, may be used for all sheet thicknesses by changing the screw. They are well suited for the fitting of curved sheets and are available from stock in lengths of 7 metres.

2 500 N/m 750 N/m2

• Reinforced

jointing profiles

3 and 2 These profiles allow larger spans and are, in general, used for 16 mm thick sheets. Watertightness is guaranteed by the use of rubber strips.

900

980/ 1200 1050

1300

1250

1000

1250

1000

1000

900

900 800

2 1

Profile span 3 and 2

L in mm Load

700

980/ 1200 1050

2 500 N/m 750 N/m2

2750

2500

1750

2500

2000

1500

900 N/m2

2000

1500

1000

Preparation and Sealing The sheets are temporary sealed for transport and storage reasons. This protection has to be removed and replaced by a definitive tape when fitting the sheets, in order to avoid dust getting into the flutes. When using multiwall polycarbonate

N/m2

700

2 3

Akyver®

sheets, it is essential to take the best information about the site where they are to be fitted: type of building, activity and exposure. Polycarbonate is permeable to water vapour (approx. 15 g/m2.24h.bar).

It is important to take this into account when recommending multiwall polycarbonate cladding. Thus the appearance of condensation may not be a cause of complaint.

www.kaysersberg-plastics.com


10

Technical information Akyver®

Preparation and Sealing

Our Recommendations - Adverse Environments • General

use

Block the upper ends of the sheet with impermeable aluminium strip and the lower ends with microperforated tape and cover it with a U-shaped profile.

• Use

in a specific environment Industrial building with strong risk of dust (dust < 50 µ): sealed using dust-proof tape at the bottom of the sheets and micro-perforated tape at the top of the sheets. Sports buildings or buildings used by the public: sealed using micro-perforated tape at the top and bottom of the sheets.

Swimming pool or damp atmosphere: avoid the use of adhesive tape. Rather use aluminium U-shaped profile or polycarbonate which promotes the evacuation of condensate and cell ventilation.

Finishing Profile The lower parts of the flutes can be fitted with a U-shaped aluminium profile for finishing and protection of the adhesive. It is recommended to use a U-shaped profile when applying microperforated tape. microperforated tape

Waterproof Seal Our experience in using waterproof seals has led us to make the following recommendation: • y ou must make sure that the seal is compatible with the sheets, because the risk of micro-cracks occuring due to chemical attack on the sheets is considerable. For this reason, we recommend that you use a “ Santoprene® ” seal.

www.kaysersberg-plastics.com


11

Technical information Storage

Akyver®

The sheets are supplied with polyethylene protection on both sides. For Akyver Sun Type® sheets, the side protected against ultraviolet light is covered with a blue printed film. These films must be removed immediately after fitting the sheets. Sheets stored outside must be protected against ambient conditions: sun, rain, etc. Pallets must be set on flat, dry ground. Take all necessary precautions during handling: • do not tighten straps excessively; • avoid bending which could drive the nails out of the pallet and damage the sheets; • do not generate scratches, dents or bulges on the surface or edge of the sheet. Sheets are supplied covered with polyethylene protective film on both sides. For sheets of Akyver Sun Type®, the UV treated side which will be exposed to the sun, is identified by a blue printed film and ink jet marking on the edge of the sheet. This film must be removed immediately after applying the sheets.

Cleaning • • • •

Akyver®

Avoid abrasive cleaners that might scratch Akyver®. Use soapy water or water containing a non-abrasive detergent. Do not use solvents or alkaline washing powders. Avoid cleaning when the sheets are hot.

A complete list of the products which are not compatible with polycarbonate is at your disposal. Please call us!

Fitting instructions

Akyver®

Joining Akyver® sheets using profiles There must be a minimum of 20 mm of the sheet structure inside the profile to give a strong join.

20 mm

www.kaysersberg-plastics.com


12

Technical information Fitting instructions

Akyver速

Fitting Akyver Sun Type速 Sheets for Roofing and Cladding Industrial and sports buildings, cladding panels, roofing, shed, roofs. When fitting Akyver sheets, national regulations must be taken into account. The following tables might help you to determine the size of the sheets and/or the need for the installation of intermediate supports, depending on the load applied on them. Minimum roofing gradient: 8.7%

L

W

www.kaysersberg-plastics.com


13

Technical information Fitting instructions •

Akyver®

Recommendation extra to technical recommendation

When fitting Akyver sheets, national regulations must be taken into account. The following tables might help you to determine the size of the sheets and / or the need for the installation of intermediate supports, depending on the load applied on them. Maximum sheet lengths or distance between 2 sheet supports (L) in mm for different sheet widths (W) and loads. Maximum deflection = 50 mm. •

Length of the sheets (mm) Thickness (mm) Load N/m2

Width (mm)

500

10 4W 16 7W 20 7W 25 7W 32 8W

6

8

10

700

2 500

3 000

4 500

> 4 500

> 6 000

> 6 000

> 6 000

> 6 000

980

1 500

2 000

2 500

2 200

> 6 000

> 6 000

> 6 000

> 6 000

1 050

1 500

2 000

2 500

2 100

6 000

> 6 000

> 6 000

> 6 000

1 200

1 800

5 000

> 6 000

> 6 000

> 6 000

750

700

1 800

2 500

4 000

> 4 000

> 6 000

> 6 000

> 6 000

> 6 000

980

1 500

1 700

2 000

1 800

4 200

6 000

> 6 000

> 6 000

1 050

1 500

1 700

2 000

1 800

3 500

5 300

5 600

> 6 000

1 200

1 500

2 500

4 400

4 700

> 6 000

900

700

1 500

3 000

4 000

> 4 000

> 6 000

> 6 000

> 6 000

> 6 000

980

1 000

1 200

1 500

1 600

3 100

5 100

5 500

> 6 000

1 050

1 000

1 200

1 500

1 400

2 500

4 700

5 000

> 6 000

1 200

1 300

2 000

3 800

4 100

> 6 000

1250

700

1 500

2 000

2 500

2 200

6 000

> 6 000

> 6 000

> 6 000

980

1 000

1 200

1 500

1 400

2 100

4 500

5 500

> 6 000

1 050

1 000

1 200

1 500

1 400

2 000

4 500

5 000

> 6 000

1 200

1 100

1 700

3 000

4 000

5 600

1500

700

1 500

1 800

2 000

6 000

> 6 000

> 6 000

> 6 000

980

1 000

1 100

1 400

2 000

3 500

4 000

> 6 000

1 050

1 000

1 100

1 400

2 000

3 500

4 000

5 600

1 200

1 000

1 500

2 000

3 000

4 700

1750

700

1 000

1 500

1 800

6 000

> 6 000

> 6 000

> 6 000

980

1 100

1 300

1 800

3 000

3 500

5 500

1 050

1 100

1 300

1 700

3 000

3 500

5 000

1 200

1 100

2 000

2 500

4 100

2000

700

1 500

6 000

6 000

6 000

> 6 000

980

1 200

1 500

2 000

2 500

5 500

1 050

1 000

1 500

2 000

2 500

5 000

1 200

1 000

1 000

1 500

4 000

Example: A 16 mm thick four-wall sheet can be fitted to take a load of 900 N/m2 in a sheet width of 700 mm by a sheet length of 6000 mm or a sheet width of 1050 mm with an intermediate support every 2500 mm.

www.kaysersberg-plastics.com


14

Technical information Fitting instructions

Akyver速

Fitting Akyver Sun Type速 Sheets for Skylights (curved sheets) Using the table below, the fitting width (W) in mm can be determined according to different radii of curvature whatever the length of the sheet. When making skylights, it is necessary to pre-bend the aluminium profiles in the workshop. Akyver Sun Type速 sheets will take the curvature of these profiles. (W) R = Radius of curvature 6 mm

Sheet width (W) in mm

R (mm) 900 R mini

1 000

1 100

1 200

1 300

1 500

1 700

1 800

600 N/m2

1 500

1 400

1 400

1 300

1 200

1 200

800

600

750 N/m2

1 300

1 200

1 100

1 100

1 050

900

500

500

900 N/m

1 200

1 100

1 050

1 050

900

700

1 200 N/m

1 050

1 050

900

800

700

500

1 400

1 500

1 700

2 000

2 300

2 500

2 700

2 2

8 mm

R (mm) 1200 R mini

600 N/m2

2 000

2 000

1 800

1 700

1 400

1 100

800

600

750 N/m

1 800

1 500

1 400

1 200

1 200

1 050

600

500

900 N/m2

1 700

1 500

1 200

1 100

1 050

800

1 200 N/m2

1 100

1 050

1 050

900

600

500

1 700

1 800

2 000

2 100

2 500

2 700

3 000

2

R (mm) 1500 R mini

10 mm

600 N/m2

2 000

2 000

1 800

1 500

1 400

1 300

1 050

800

750 N/m

2 000

1 800

1 600

1 400

1 300

1 050

900

700

900 N/m

2 000

1 700

1 500

1 400

1 200

900

700

500

1 200 N/m2

1 300

1 200

1 200

1 050

900

700

600

500

1 700

1 800

2 000

2 100

2 500

2 700

3 000

1 800

1 800

1 600

1 300

1 300

1 200

900

700

2 2

10 mm

R (mm) 1500 R mini

4 Walls 600 N/m2

750 N/m2

1 400

1 400

1 200

1 200

1 000

900

800

600

900 N/m

1 700

1 200

1 200

1 100

1 000

800

600

400

1 200 N/m

1 100

1 000

1 000

1 000

800

600

500

400

1 700

1 800

2 000

2 100

2 500

2 700

3 000

2 000

2 000

1 800

1 500

1 400

1 300

1 050

800

2 2

16 mm

R (mm) 1500 R mini

4 Walls 600 N/m2

750 N/m2

2 000

1 800

1 600

1 400

1 300

1 050

900

700

900 N/m2

2 000

1 700

1 500

1 400

1 200

900

700

500

1 200 N/m

1 300

1 200

1 200

1 050

900

700

600

500

2 900

3 000

3 300

3 600

3 900

4 200

4 500

2 000 1 500 1 200 1 050

1 800 1 400 1 200 900

1 600 1 200 1 050 800

1 400 1 100 900 700

1 300 1 050 800 700

1 200 900 700 600

1 050 800 700 500

16 mm 7 Walls 1

2

R (mm) 2800 R mini 600 750 900 200

N/m2 N/m2 N/m2 N/m2

2 000 1 600 1 400 1 100

www.kaysersberg-plastics.com


15

Technical information Profiles and accessories

Akyver速

Aluminium Profiles Top aluminium profile screw fixing

Bottom aluminium profile Ref.:

ZEA 587: 7 lm and ZEA 591: 6 lm

Ref.:

Reinforced bottom aluminium profile

ZEA 585: 7 lm and ZEA 592: 6 lm

13

ZEA 590: 7 lm

30

8

60

60

(only for 16 mm sheets) Side aluminium profile Ref.:

Ref.:

ZEA 586: 7 lm

60

Rubber base profile SANTOPRENE速

Top aluminium profile clip fixing

Roll of 50 lm Ref.:

ZEA 2001

Ref.:

ZEA 594: 7 lm 60

29 8 60

60

13

End aluminium profile16 mm Ref.:

5,4 14

End aluminium profile 10 mm

ZEA 589: 6,3 lm

Ref.:

ZEA 588: 6,3 lm 16

16

10

16

18

18

Accessories Rubber joint SANTOPRENE速

PC closing device

Aluminium tape

Roll of 100 lm Ref.: ZEA 2000

Per 200 units Ref.: ZEA EMBOUT

Roll of 50 lm Ref.: ZCF 086: 7 lm

15

44 62

Micro-perforated tape Roll of 33 lm Ref.: ZCF 095

38

www.kaysersberg-plastics.com


The Solution for Each Application

Akyver

Kaysersberg Plastics Products

DS Smith Kaysersberg SAS

B.P. 27 68240 Kaysersberg Tel.: +33 (0)3 89 78 32 43 Fax: +33 (0)3 89 78 38 56 Email: severine.battaini@kayplast.com The information contained in this document is for information purposes and is non-contractual. The manufacturer reserves the right to change the product and its technical characteristics. This information has been supplied in good faith and does not in any way constitute a guarantee for specific conditions of use. This document cancels and replaces the version of 12/05. DS SMITH KAYSERSBERG - ĂŠtablissement Plastiques - SAS au capital de 53 816 000 e - RCS COLMAR 572 219 202 SIRET 572 219 202 00072

VER 062 GB - 12/2009 Eurhode business services - F-68040 Ingersheim

ÂŽ


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.