Vlp 40w leddriver

Page 1

40W Single Output Switching Power Supply

VLC-40P SERIES FEATURES: •Universal AC input / Full range (up to 305VAC) •Built-in active PFC function •High Efficiency up to 90% •Protections: Short circuit / Over current / Over voltage / Over temperature •Cooling by free air convection •Fully isolated plastic case •IP67 design for indoor or outdoor installations (Note.9) •Class 2 power unit •Suitable for LED lighting and moving sign applications •Compliance to worldwide safety regulations for lighting •Suitable for dry / damp / wet locations •3 years warranty (Note.10)

IP67 SEPCIFICATION MODEL OUTPUT

INPUT

PROTECTION

DC VOLTAGE CONSTANT CURRENT REGION Note.4 RATED CURRENT RATED POWER RIPPLE & NOISE (max) Note.2 VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME Note.7 HOLD UP TIME VOLTAGE RANGE Note.5 FREQUENCY RANGE POWER FACTOR TOTAL HARMONIC DISTORTION EFFICIENCY AC CURRENT INRUSH CURRENT LEAKAGE CURRENT OVER CURRENT Note.4 SHORT CIRCUIT OVER VOLTAGE

OVER TEMPRATURE ENVIRONMENT WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY & EMC SAFETY STANDARDS Note.6

OTHER

NOTE

WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF DIMENSION PACKING

VLP-40-700 VLP-40-900 VLP-40-1000 VLP-40-1500 58V 46V 40V 24V 36 ~ 58V 24 ~ 46V 20~40V 9~24V 700mA 900mA 1000mA 1500mA 40.6W 41.4W 40W 36W 5.6Vp-p 4.4Vp-p 3.2Vp-p 2.4Vp-p ±4.0% ±4.0% ±4.0% ±4.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±1.0% 2000ms, 200ms at 95% load 230VAC / 115VAC 16ms/230VAC 16ms/115VAC at full load 90 ~ 305VAC 127 ~ 431VDC 47 ~ 63Hz PF>0.97/115VAC, PF>0.96/230VAC, PF>0.95/277VAC at full load THD< 20% when output loading 60% at 115VAC/230VAC input and output loading 75% at 277VAC input 91% 91% 90% 89.50% 0.64A / 115VAC 0.32A / 230VAC 0.3A / 277VAC COLD START 55A(t =265 s measured at 50% I ) at 230VAC <0.75mA / 277VAC 95 ~ 110% Protection type : Constant current limiting, recovers automatically after fault condition is removed Hiccup mode, recovers automatically after fault condition is removed 65 ~ 73V 54 ~ 60V 46 ~ 50V 31 ~ 35V Protection type : Shut down o/p voltage, re-power on to recover Shut down o/p voltage, recovers automatically after temperature goes down -40 ~ +70 (Refer to "Derating Curve") 20 ~ 95% RH non-condensing -40 ~ +80 , 10 ~ 95% RH ± 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes UL8750, CSA C22.2 No. 250.0-08(except for 48V, 54V), EN61347-1, EN61347-2-13 independent, IP67, J61347-1, J61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1 I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3 Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A 301.6K hrs min. MIL-HDBK-217F (25 ) 120*34*28mm (L*W*H) 0.4Kg;20pcs/9Kg/0.53CUFT

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambien t temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Please refer to "DRIVING METHODS OF LED MODULE". 5. Derating may be needed under low input voltages. Please check the static characteristics for more details. 6. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 9. Suitable for indoor use or out door use withour direct sunlight exposure. Please avoid immerse in the water over 30 minutes. 10. Refer to warranty statement.


VLC-40P SERIES

40W Single Output Switching Power Supply Mechanical Specification

120mm

30±30mm

30±30mm

ACN (BLUE)

34mm

UL1015 18AWG

ACL (BROWN)

V+ (RED)

28mm

UL1007 16AWG

T case

° T case: Max. Case Temperature. Recommend Mounting Direction

Block Diagram

I/P

POWER SWITCHING

& RECTIFIERS

RECTIFIERS & FILTER

+V -V O.C.P.

O.L.P.

PWM CONTROL

DETECTION CIRCUIT

100

100

90 80

80 70

60

60

40

50 20

-30

40 -15

0

15

30

40

50

60

70 (HORIZONTAL)

90

100

125

135

145

155 165

175

180

200

230

264

V(WHITE)