www.wagospb.ru
Our Power Team
Силовые клеммы для проводов до 185 мм2, монтируемые на дин-рейку
POWER CAGE CLAMP® vibration-proof – fast – maintenance-free
www.wagospb.ru
Main application areas:
Benefits
energy-intensive industries, including machinery and equipment manufacturing, as well as energy production
Fast termination: no time-consuming preparation – no ring terminals or ferrules required
Easy termination: • Side-entry design • Orange locking tab keeps the clamp open for hands-free wiring
Виброустойчивы, не требуют обслуживания
2
www.wagospb.ru
eXTRem beständig von −40 °C bis +70 °C Использование пружины вместо винтов - ключ к популярности клемм WAGO. Пружинные клеммы обеспечивают необходимое прижимное усилие для проводников до 35, 50, 95 и 185 мм² Always reliable: Optimum clamping force – independent of operator skill Suitable for all applications: • The high-current terminal blocks meet the most stringent requirements, including those specified for railway and marine applications. • Resistant to heat and cold, even under the heaviest of loads.
The latest and largest member of our high-current family: 185 mm² connected via spring pressure
• 353 A • AC/DC up to 1000 V • DC up to 1500 V
3
www.wagospb.ru
Handling
Установка и снятие Установка
Снятие
Клеммы с заземлением
Snapping a terminal block onto DIN rail (to the left or to the right).
Removing a terminal block from the assembly (to the left or to the right).
Firmly snap ground conductor terminal block onto DIN rail. The contact foot is secured, providing the appropriate power grounding connection.
Заземляющий контакт
Ground conductor terminal blocks (limited to max. 120 mm2/250 kcmil for the 285-1187 model acc. to EN 60947-7-2) must be snapped onto a 2.3 mm thick copper DIN rail.
Безопасность
4
Assembly
Shock protectors
Warning covers
Conductors
Risk of injury! Keep fingers out of the conductor entry hole!
Yellow, detachable shock protectors for jumper slots and/or unused conductor entry points.
Provide visual indication for high-voltage applications, and may indicate: Caution! Power is still on even after switching off the main switch!
1. Bend conductor 2. Cut conductor to length (Conductor end must be straight!) 3. Strip conductor (Observe strip length printed on terminal block!)
www.wagospb.ru
Клеммы 35 мм2 Terminating 35 mm2 conductors
Turn the screwdriver counter-clockwise to the stop !. Next, push the orange locking tab. The clamp is locked open for hands-free wiring.
Insert stripped conductor into the clamping unit until it hits backstop. Hold this position.
A small counter-clockwise rotation " releases the latch. When unlocked, allow the screwdriver to rotate clockwise to securely clamp the conductor.
Клеммы 50–185 мм2
Terminating 50, 95 and 185 mm2 conductors
Rotate the T-wrench counter-clockwise to the stop !. Next, push in the orange locking tab. The clamp is locked open for hands-free wiring.
Insert stripped conductor into the clamping unit until it hits backstop. Hold this position.
Printing (185 mm2)
A short counter-clockwise rotation " releases the tab. When unlocked, allow the T-wrench to rotate clockwise to securely clamp the conductor.
Маркировка
The rotational direction of the T-wrench is indicated via “open” and “unlock” arrows on the 185 mm² (350 kcmil) terminal block. The strip length is also printed on all other 285 Series models.
Marking accessories
WMB markers are suitable for all high-current terminal blocks. Marking strips must be applied directly to the on 35 mm2 (2 AWG) terminal blocks.
Marking strips can be applied to 35–95 mm2 (2–4/0 AWG) terminal blocks using an adapter.
In addition to WMB markers, marking strips can be directly applied to 185 mm2 (350 kcmil) terminal blocks.
5
www.wagospb.ru
Handling
Объединение Commoning 35 mm2 terminal blocks
Commoning adjacent terminal blocks using a centrally positioned push-in jumper.
Slide the marking strip laterally to remove the jumper.
Commoning 50, 95 and 185 mm2 terminal blocks
Commoning 35 mm2 (2 AWG) high-current terminal blocks with 10/16 mm2 (8/6 AWG) TOPJOP® S terminal blocks using step-down jumpers.
Тестирование Testing (35 mm2) Commoning with adjacent jumper: Inserting the jumper above the conductor entry hole – prior to conductor termination. The nominal cross-section remains unchanged.
Testing (50–185 mm2)
Removing jumper using operating tool.
Easy troubleshooting via 4 mm Ø touch-proof test plug. A test plug adapter (283-404) is used for the 35 mm2 (2 AWG) terminal block. (Test plugs are not offered by WAGO – e.g., mfd by Multi-Contact Deutschland GmbH.)
Power tap and built-in test point (35 mm2)
Installed in the jumper slot, the power tap can be fitted with a strain relief plate and offers a built-in test point for 2 mm Ø test plugs. 6
Power tap (50–95 mm2, 185 mm2 pending)
Power tap provides safe and easy power distribution to additional loads. Insert the unwired tap before actuating the spring.
www.wagospb.ru
285 Series
249-197 Стопор
285 Series Item Numbers Описание
35 mm2
50 mm2
95 mm2
185 mm2
Conductor sizes
6–35 mm2
10–50 mm2
25–95 mm2
50–185 mm2
125 A 1000 V
150 A 1000 V
232 A 1000 V
353 A 1000 V AC/DC 1500 VDC
Проходная клемма
285-135
285-150
285-195
285-1185
Проходная клемма
285-134
285-154
285-194
285-1184
Клемма с заземлением
285-137
285-157
285-197
285-1187 285-1171
Nominal current I Rated voltage
N
285-1169 185 mm² Набор для трехфазной сети
(ground acc. to max. 120 mm2 stantard)
Перемычка
285-435
285-450
285-495
Понижающая перемычка (для TOBJOP® S)
285-430
-
-
-
Power tap
285-427
285-447
285-407
pending
Three phase set (without DIN rail and marking accessories)
285-139
285-159
285-199
285-1169
Warning cover
285-420
285-440
285-170
285-1177
Shock protector
285-421
285-441
285-169
285-1178
Marking strips (roll)
2009-110
2009-110
2009-110
2009-110
Marking strip adapter
285-442
285-442
285-442
WMB Inline markers (roll)
2009-115
2009-115
2009-115
2009-115
WMB Multi marking system (for 5–5.2 mm)
793-5501
793-5501
793-5501
793-5501
210-721
285-172
-
7