TABLE OF CONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Read Before Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Pre-Installation Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Items In the Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Tools You Will Need . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Installation Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Installation Steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Account Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Product SpeciďŹ cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Limited Warranty for Lumin Smart Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
INSTALLATION MANUAL
Lumin Smart Panel - Dedicated Circuits
INTRODUCTION Welcome! The Lumin Smart Panel – Dedicated Circuits (LSP-DC) is a stand-alone product that extends the capability of an existing circuit breaker panel (or “electrical panel”) by providing measurement and remote control of up to twelve (12) dedicated circuits in a home or building. The function of the circuit breaker panel remains the same and is not impacted. The LSP-DC securely and safely transmits real-time consumption information to the cloud via customer Wi-Fi. The information can be accessed through a user dashboard (software) for home/building owners. The Lumin dashboard gives customers insights into their energy consumption and energy costs, as well as provides the user with the ability to control or automate their energy use remotely. This manual describes the installation of the LSP-DC hardware. All information regarding access to the user dashboard can be found in the Account Set Up Guide. Need help? For installation assistance please contact Lumin by e-mail at support@luminsmart.com or by phone at 1-888-421-0616 (North America).
WARNING: HIGH VOLTAGE. THE LUMIN SMART PANEL MUST BE INSTALLED BY A LICENSED ELECTRICIAN
1
INSTALLATION MANUAL
Lumin Smart Panel - Dedicated Circuits
READ BEFORE USE The LSP-DC is compatible with both flush-mounted (i.e. set within drywall) existing electrical panels and surface-mounted electrical panels. Please determine which electrical panel type the LSP-DC will be connecting to and follow the corresponding installation steps outlined in this manual. The LSP-DC must be installed indoors. Please review the product’s technical ratings and specifications (pg. 22) to confirm it is suitable for your application prior to installation. NOTE: The Circuit Breaker & LSP Labeling Table (provided with the LSP-DC) must be completed and delivered to the home/building owner upon the successful installation of the LSP-DC. A completed table is required in order for users to set up their user account.
Warnings The LSP-DC connects to dangerous voltages. The improper use or installation of the device can lead to serious or fatal injuries. Please observe the following safety precautions when installing the LSP-DC: • The product must be installed by a licensed electrician • Review all the instructions before you start the installation • Personal protective equipment should be worn when installing the product • Do not use the product in any way other than its intended use • Do not install or operate the product outdoors or in damp/wet conditions • Do not install or operate the product in extreme temperatures • Do not open, attempt to access or touch any internal product parts • Do not use the product if it is damaged or appears to be damaged • Use only the wires and cables supplied with the product • Do not connect the product to circuit breakers higher than 60 amps • Adhere to all local and national safety regulations for installation and use
2
INSTALLATION MANUAL
Lumin Smart Panel - Dedicated Circuits
PRE-INSTALLATION CHECKLIST Items in the Box
1 LSP with Conduit, Conduit Bushings & Wire Whips Attached
2 Mounting Brackets (Surface-mounted Installation Only)
NOTE: Additional items include installation hardware, a LSP Circuit Label Table, an Account Setup Guide, an Installation Overview and a hole-location template for mounting the LSP (including a drywall-cutout template for flush-mounted installations).
3
INSTALLATION MANUAL
Lumin Smart Panel - Dedicated Circuits
PRE-INSTALLATION CHECKLIST Tools You’ll Need
Drill
Wire nuts
Manual knockout
Drywall Saw
Tape measure
Wire stripper
Phillips screwdriver
Flathead screwdriver
Level (optional)
4
INSTALLATION MANUAL
Lumin Smart Panel - Dedicated Circuits
INSTALLATION Installation Overview STEP 1. Turn off main feed & remove the electrical panel cover
STEP 9. Connect the LSP neutral wires to the neutral bar
STEP 2 (Flush-mount Only). Measure & remove the drywall cutout
STEP 10. Select a circuit breaker, turn it off & disconnect the load
STEP 3. Knock out two holes in bottom of the electrical panel
STEP 11. Connect a LSP wire labeled “A” to the circuit breaker
STEP 4. Measure & mark hole locations for mounting the LSP
STEP 12. Connect a LSP wire labeled “B” to the load and turn the circuit breaker back on
STEP 5 (Surface-mount Only). Secure mounting brackets to the wall
STEP 13. Record circuit breaker name and corresponding LSP wire number
STEP 6. Guide the LSP wire whips through the electrical panel
STEP 14. Repeat steps 10-13 for remaining circuit breakers
STEP 7. Secure the LSP to the wall/ bracket & electrical panel
STEP 15. Replace the electrical panel cover
STEP 8. Connect the LSP ground wires to the ground bar
5
INSTALLATION MANUAL
Lumin Smart Panel - Dedicated Circuits
Installation Steps STEP 1. Turn Off Main Feed & Remove Electrical Panel Cover
WARNING: HIGH VOLTAGE.
Tools: Screwdriver
6
INSTALLATION MANUAL
Lumin Smart Panel - Dedicated Circuits
STEP 2 (Flush-Mount Only). Measure and Remove the Drywall Cutout
Drywall Cutout Option A
Drywall Cutout Option B
Tools: Tape measure, level (optional) and drywall saw or suitable alternative NOTE: Utilize the template provided with the LSP to quickly and accurately trace the proper location and dimensions of the drywall cutout. Select the template for “Option B” if additional space is required to properly access the electrical panel to complete Step 3. 7
INSTALLATION MANUAL
Lumin Smart Panel - Dedicated Circuits
STEP 3. Knock Out Two Holes for 2� Conduit in Bottom of the Electrical Panel
WARNING: HIGH VOLTAGE.
Tools: Knockout punch or suitable alternative NOTE: Exact hole locations in bottom of panel may very depending on spacing constraints; place hole locations as needed to avoid any existing obstructions.
8
INSTALLATION MANUAL
Lumin Smart Panel - Dedicated Circuits
STEP 4. Measure and Mark Hole Locations for Mounting the LSP
Surface-mounted installation
Flush-mounted installation
Tools: Tape measure and level (optional) NOTE: Utilize the template provided with the LSP to quickly and accurately mark the proper hole locations; ensure to mark the applicable hole locations for your installation type (ushmount vs. surface-mount). 9
INSTALLATION MANUAL
Lumin Smart Panel - Dedicated Circuits
STEP 5 (Surface-mount Only). Secure Mounting Brackets to Wall
Tools: Drill, screws (x4) and washers (x4)
10
INSTALLATION MANUAL
Lumin Smart Panel - Dedicated Circuits
STEP 6. Guide the LSP Wire Whips Through the Electrical Panel
Surface-mounted installation
Flush-mounted installation
WARNING: HIGH VOLTAGE.
NOTE: Rest the LSP on the ground when guiding the wire whips through the two holes in the bottom of the electrical panel. Remove the conduit bushings before guiding the wire whips through the two holes. The 6 AWG and 10 AWG wires should be fed through separate holes.
11
INSTALLATION MANUAL
Lumin Smart Panel - Dedicated Circuits
STEP 7. Secure the LSP to the Wall/Bracket and Electrical Panel
Surface-mounted installation
Flush-mounted installation
WARNING: HIGH VOLTAGE.
Tools: Drill, screws (x4), washers (x4) and nuts (x4: surface-mount only) NOTE: Lift the LSP to align with the mounting holes and secure it directly to the wall (flushmount installation) or mounting bracket (surface-mount installation) utilizing the hardware provided. Secure the LSP to the electrical panel with the two 2” conduit bushings provided. 12
INSTALLATION MANUAL
Lumin Smart Panel - Dedicated Circuits
STEP 8. Connect the LSP Ground Wires to the Ground Bar
X2
WARNING: HIGH VOLTAGE.
Tools: Screwdriver NOTE: Connect the two ground wires from the LSP to the existing ground bar in the electrical panel (exact location of ground bar may vary).
13
INSTALLATION MANUAL
Lumin Smart Panel - Dedicated Circuits
STEP 9. Connect the LSP Neutral Wires to the Neutral Bar X2
WARNING: HIGH VOLTAGE.
Tools: Screwdriver and wire stripper NOTE: Connect the two neutral wires from the LSP to the existing neutral bar in the electrical panel (exact location of neutral bar may vary).
14
INSTALLATION MANUAL
Lumin Smart Panel - Dedicated Circuits
STEP 10. Select Circuit Breaker, Turn it Off and Disconnect Load
WARNING: HIGH VOLTAGE.
Tools: Screwdriver
15
INSTALLATION MANUAL
Lumin Smart Panel - Dedicated Circuits
STEP 11. Connect a LSP Wire Labeled “A” to the Circuit Breaker
“A”
WARNING: HIGH VOLTAGE.
Tools: Screwdriver and wire stripper NOTE: The LSP can connect to circuit breakers rated up to 60 amps for lines 1-6 (6 AWG wires) and to circuit breakers rated up to 30 amps for lines 7-12 (10 AWG wires).
16
INSTALLATION MANUAL
Lumin Smart Panel - Dedicated Circuits
STEP 12. Connect a LSP Wire Labeled “B” to the Load and Then Turn the Circuit Breaker Back On
“B”
WARNING: HIGH VOLTAGE.
Tools: Wire stripper and wire nut NOTE: Please ensure a tight connection is made with the LSP’s “B” wire (stranded) and the existing load (solid). Do not turn the circuit breaker back on until the connection is completed. 17
INSTALLATION MANUAL
Lumin Smart Panel - Dedicated Circuits
STEP 13. Record Circuit Breaker Label With the Corresponding LSP Wire Number
LSP LINE #
CIRCUIT BREAKER LABEL
LSP LINE #
1
7
2
8
3
9
4
10
5
11
6
12
CIRCUIT BREAKER LABEL
NOTE: Record the circuit breaker label with the corresponding LSP line number in the Circuit Breaker & LSP Labeling Table provided with the LSP-DC (ex. record “refrigerator” next to LSP Wire number 3 if the circuit breaker labeled “refrigerator” was connected to the LSP’s wire numbered 3). Dual pole circuit breakers will require two LSP wire numbers.
18
INSTALLATION MANUAL
Lumin Smart Panel - Dedicated Circuits
STEP 14. Repeat Steps 10-13 for Remaining Circuit Breakers
X 12
WARNING: HIGH VOLTAGE.
Tools: Screwdriver, wire stripper and wire nuts NOTE: The LSP can connect to up to 12 circuit breakers. Please ensure the LSP’s line labeled “7A” is connected to a circuit breaker as it provides power to the LSP.
19
INSTALLATION MANUAL
Lumin Smart Panel - Dedicated Circuits
STEP 15. Replace the Electrical Panel Cover
Surface-mounted installation
Flush-mounted installation
WARNING: HIGH VOLTAGE.
Tools: Screwdriver NOTE: Please make any necessary drywall repairs (if applicable) and clean up the area around the circuit breaker panel once the LSP installation is completed.
20
INSTALLATION MANUAL
Lumin Smart Panel - Dedicated Circuits
ACCOUNT SETUP Once the installation of your LSP is completed, please refer to the Account Setup Guide provided with your LSP or go to https://luminsmart.com/accountsetup to establish a user account and to access the LSP dashboard (software). You will need your local Wi-Fi network credentials and the completed LSP Circuit Label Table to complete your account setup. For account setup assistance or troubleshooting, please call 1-888-421-0616 (North America) or e-mail support@luminsmart.com.
21
INSTALLATION MANUAL
Lumin Smart Panel - Dedicated Circuits
PRODUCT SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS
COMPATABILITY & COMPLIANCE
Operating Temperature
-40°C to 85°C (-40°F to 185°F)
Panel
Any manufacturer
Enclosure Type
Rittal KL 1511.510
Breakers
Any manufacturer
RoHS Compliant
Yes
Compliance
PHYSICAL SPECIFICATIONS
UL 61010 INSTALLATION
Dimensions
40.0cm x 40.0cm x 12.0cm
Licensed electrician
Required
Weight
15.2kg
Type
Indoor wall mount
Conductor Length
50.8cm
Time
PERFORMANCE SPECIFICATION
2-3 hours SUPPORTED CIRCUIT BREAKERS & LOADS
AC Voltage
120/240V
Amperage
Up to 60 amps per channel
Feed-In Type
Single & Dual Phase
# of Circuit Breakers
Dedicated Circuits, up to 12
Warranty
1 Year CONNECTIVITY & SECURITY
ENERGY MEASUREMENT SPECIFICATIONS
Wi-Fi: 802.11b/g/n @ 2.4GHz with Internet access
Each dedicated circuit metered separately
WEP 64, WEP 128, WPA and WPA2 encryption methods
Revenue Grade
DHCP (dynamic) or static IP addressing
ANSI C12.20 0.5 Accuracy Class
X.509 certificate encryption
Ability to determine loads less than 1.0W
Cryptographic protocol: TLS RFC 6176
20 kHz sampling frequency per circuit
AWS Multi-Region High Availability
Class 3 PCB Assembly
22
INSTALLATION MANUAL
Lumin Smart Panel - Dedicated Circuits
LIMITED WARRANTY FOR LUMIN SMART PANEL This Limited Warranty gives you specific legal rights and you may also have other rights, which vary from state to state. The Limited Warranty can also be found online at https://luminsmart.com/legal/warranty and in the documentation we provide with the product. We warrant that during the warranty period, the product will be free from defects in materials and workmanship. We limit the duration and remedies of all implied warranties, including without limitation the warranties of merchantability and fitness for a particular purpose to the duration of this express limited warranty. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you. Our responsibility for defective goods is limited to repair, replacement, or refund as described below in this warranty statement. Who May Use This Warranty? Coulomb Inc. (d/b/a Lumin), a Delaware corporation located at address 212 East Main Street, Suite 202, Charlottesville, VA 22902 (“we”) extend this limited warranty only to the consumer who originally purchased the product (“you”). It does not extend to any subsequent owner or other transferee of the product . What Does This Warranty Cover? This limited warranty covers defects in materials and workmanship of the Lumin Smart Panel (the “product”) for the Warranty Period as defined below. What Does This Warranty Not Cover? This limited warranty does not cover any damage due to: (a) transportation; (b) storage; (c) improper installation; (d) improper use; (e) failure to follow the product instructions or to perform any preventive maintenance; (f) modifications; (g) opening the Lumin Smart Panel or tampering with its internal components; (h) unauthorized repair; (i) normal wear and tear; or (j) external causes such as accidents, abuse, flooding, storms, or other actions or events beyond our reasonable control. This limited warranty also does not apply to the software, mobile applications, technology and services provided by Lumin which enable you to remotely access and view data that is collected, stored and transmitted by the product concerning electricity consumption and/or to remotely control electrical circuits which the product is connected to (the “Lumin Service”). Use of the Lumin Service is subject to and governed by the terms of the Lumin Service User Agreement, a copy of which can be accessed at www.lumin.com/legal/useragreement. Any warranties provided by Lumin with respect to the Lumin Service are only those warranties expressly set forth in the Lumin Service User Agreement What Is The Period Of Coverage? This limited warranty starts on the date of your purchase and lasts for one year (the “Warranty Period”). The Warranty Period is not extended if we repair or replace the product. We may change the availability of this limited warranty at our discretion, but any changes will not be retroactive. What Are Your Remedies Under This Warranty? With respect to any defective product during the Warranty Period, we will, in our sole discretion, either: (a) repair or replace such product (or the defective part) free of charge or (b) refund the purchase price of such product. We will also pay for shipping and handling fees to return the repaired or replacement product to you if we elect to repair or replace the defective product. How Do You Obtain Warranty Service? To obtain warranty service, you must call 1-888-421-0616 or e-mail support@luminsmart.com during the Warranty Period to obtain a Defective Merchandise Authorization (“DMA”) number. No warranty service will be provided without a DMA number. Limitation of Liability. The remedies descried above are your sole and exclusive remedies and our entire liability for any breach of this limited warranty. Our liability shall under no circumstances exceed the actual amount paid by you for the defective product, nor shall we under any circumstances be liable for any consequential, incidental, special or punitive damages or losses, whether direct or indirect. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
23
SUPPORT@LUMINSMART.COM 1-888-421-0616 WWW.LUMINSMART.COM
® U.S. Registered Trademark. Patents pending. Copyright © 2018 Coulomb, Inc. (DBA Lumin). All rights reserved.