MXZ-VA SERIES For saving space... Multiple indoor units can be connected to a single outdoor unit. Wall-mounted Ceiling-concealed PEAD-RP71
MSZ-G=22/25/35/42/50
MSZ-F=25/35/50
SEZ-KD25/35/50/60/71
Ceiling-suspended
MSZ-G=60/71/80
PCA-RP50/60/71 MSZ-EF22/25/35/42/50
Outdoor unit
4 port/5 port
2 port
Power ceiling-cassette
2 Ă—2 ceiling-cassette
MXZ-4D80VA MXZ-5D100VA
MXZ-2D52VA
Floor-standing
6 port 3 port/4 port
PLA-RP60/71
MFZ-KJ25/35/50
SLZ-KA25/35/50
MXZ-3D54VA MXZ-4D71VA
MXZ-6D120VA
Compact Outdoor Unit Saves Space
Select from a Wide Range of Stylish Indoor Units
The MXZ Series can be connected to 2, 3, 4, 5 or 6 indoor units, optimising the use of outdoor space and enhancing exterior aesthetics. In addition the MXZ 2-port model is downsized by 30% compared with the conventional model.
For an attractive installation and optimum use of indoor space, choose the system that best matches your needs from 10 types including wallmounted, floor-standing, ceiling-concealed, ceiling-cassette and ceilingsuspended units. Floorstanding
Wall-mounted
N Compact outdoor units
550mm
285
Conventional model
MSZ-F
40kg mm
800mm
MXZ-2D52VA
MSZ-EF
MSZ-G
Ceilingconcealed
MFZ
SEZ
Ceilingcassette PEAD
SLZ
Ceilingsuspended
PLA
PCA
25 35 50 22 25 35 42 50 22 25 35 42 50 60 71 80 25 35 50 25 35 50 60 71 71 25 35 50 60 71 50 60 71
L L L
L L L
L L
L L
L L
MXZ-2=52VA
L L
MXZ-3=54VA
L L L L L L L L L L L L L
L L L L L L
L L L
L
MXZ-4=71VA
L L L L L L L L L L L L L L
L L L L L L L
L L L L
L L
MXZ-4=80VA
L L L L L L L L L L L L L L L
L L L L L L L L L L L L L L L L L
MXZ-5=100VA L L L L L L L L L L L L L L L
L L L L L L L L L L L L L L L L L
MXZ-6=120VA L L L L L L L L L L L L L L L L L L L L L L L L
29
L L L L L L L L L
Energy Saving with High AEER and ACOP
Fix Operation Mode
Thanks to inverter technology, we have realised a higher energy efficiency ACOP of 4.03 (MXZ-4D71VA in heating) for maximum comfort.
“Fix Operation Mode” can be selected to prevent operating in an erroneous mode. This is especially convenient in places where many people gather, such as in hotels.
ACOP
4.03
Operable under Low Outdoor Temperatures
Quiet Operation (Silent Mode)*
Even when it is as cold as -15°C outside, both heating and cooling operation are possible. Cooling may be suitable in winter for crowded spaces such as in pubs.
With the MXZ outdoor unit, operating noise (outdoor) is just 46dB* (MXZ-4D80 in cooling mode). In combination with the MSZ-FB25VA, indoor noise can also Indoor Outdoor Only Only be reduced to a quiet 20dB.
20 46
*Quiet mode needs to be set when installed.
dB
Longer Piping Length To ease installation work at any site, piping is extendable up to 80 metres* in total length and 15 metres in height (additional refrigerant charge may be required).
dB
Advanced Remote Controller
*MXZ-5/6
The optional wired remote controller (PAR-31MAA*) with a weekly timer function enables eight separate pattern settings in a single day.
Max. height difference
Max. piping length Indoor unit
*Requires optional interface (MAC-333IF-E)
if indoor type is wall-mounted and floor-standing.
15m
Indoor unit
Outdoor unit
b
a
a+b=80m
Outdoor unit
PAR-31MAA
MXZ Specifications Type Model Name Power Supply [V, Phase, Hz, Source] Cooling
Up to 2 indoor units Up to 3 indoor units
MXZ-2D52VA Rated Min. - Max.
Capacity
kW kW kW
Power Input [Indoor + Outdoor] AEER/EER [Indoor + Outdoor] A Running Current [Indoor + Outdoor] Sound Pressure Level [Outdoor] Silent - High dB(A) /s Air Volume [Outdoor] Heating Capacity
Rated
kW
Min. - Max.
kW kW
Power Input [Indoor + Outdoor] ACOP/COP [Indoor + Outdoor] A Running Current [Indoor + Outdoor] Sound Pressure Level [Outdoor] Silent - High dB(A) /s Air Volume [Outdoor] Min. - Max. Number of Connectable Indoor Units Breaker Size Height
Outdoor Dimensions
Width Depth Ext. Piping
Weight Diameter
Liquid ( ) Gas ( ) Total - Each
Max. Length
mm kg mm mm m m
8.0 3.7 - 9.2 2.07 3.59 / 3.86
5.4 2.9 - 6.8 1.25
3.67 / 3.71 6.3 46 - 50 525
3.95 / 4.32 5.5 45 - 50 648
6.1 1.0 - 7.0 1.59
7.0 2.6 - 9.0 1.61
8.0 3.4 - 10.7
3.80 / 3.84
4.06 / 4.35
7.1 49 - 53
7.1 48 - 53
4.03 / 4.35 8.1 48 - 54
3.86 / 4.13 9.4
532 2
755 2-3
15
25
550 800 285
710 840 330
12.0 3.5 - 13.5 3.61
3.07 / 3.24 13.6 49 - 53 973
3.18 / 3.32 15.9 51 - 53 987
10.0 4.1 - 14.0 2.63
13.5 3.5 - 16.5 3.75
3.58 / 3.80
3.45 / 3.60
46 - 51
11.6 49 - 59
16.5 53 - 57
778 2-4 25
833 2-4
1050 2-5
1158 2-6
25
25
32
710
915
840 330
900 320
915 900 320
1070 900 320
69
45 - 50 648
1.84
37
57
58
6.35 x 3 9.52 x 3
6.35 x 4
30 - 20
50 - 25 15 / 10* 40 -10 ~ +46 -15 ~ +24
m °C
Heating
°C
-15 ~ +24
Up to 5 indoor units Up to 6 indoor units
10.0 3.9 - 11.0 3.09
3.7 - 8.8 1.88 3.50 / 3.78 8.3
6.35 x 2 9.52 x 2
Cooling
Refrigerant Chargeless Piping Length
7.1
5.2 1.1 - 6.0 1.40
15 / 10* 20 -10 ~ +46
Max. Height Guaranteed Operating Range [Outdoor unit]
A mm mm
Up to 4 indoor units
MXZ-4D71VA MXZ-4D80VA MXZ-5D100VA MXZ-6D120VA MXZ-3D54VA 230V, Single, 50Hz, Outdoor unit power supply
(NOTE) Model name shows rated cooling capacity when max. quantity of indoor units are connected. MXZ-5D100VA: 10kW at rated connected with 5 indoor units.
9.1 46 - 51 910 8.8 3.4 - 11.6 2.13
6.35 x 4 9.52x3 + 12.7x1 9.52x3+12.7x1 60 - 25 70 - 25 15 / 10* 15 / 10*
70
87
6.35 x 5 9.52x4+12.7x1
6.35 x 6 9.52x5+12.7x1
80 - 25
80 - 25 15 / 10* 60 -10 ~ +46 -15 ~ +24
40 -10 ~ +46
40 -10 ~ +46
15 / 10* 40 -10 ~ +46
-15 ~ +24
-15 ~ +24
-15 ~ +24
(Rating Conditions) Cooling: Indoor 27°C, D.B./19°C, W.B. Outdoor 35°C, D.B. Heating: Indoor 20°C, D.B./15°C, W.B. Power input, running current and AEER/ACOP are the figures when connected with below indoor units. Outdoor 7°C, D.B./6°C, W.B. MXZ-2D52VA MSZ-GE35VAD×2 MXZ-3D54VA MXZ-4D71VA MXZ-4D80VA MXZ-5D100VA MXZ-6D120VA
MSZ-GE25VAD×3 MSZ-GE25VAD×4 MSZ-GE25VAD×4 MSZ-GE25VAD×5 MSZ-GE25VAD×6
*If the outdoor unit is installed higher than the indoor unit, max. height is reduced to 10m.
30