BERKER B.IQ
DESIGN & VERSIONS CONSTRUCTION & DIMENSIONS STRUCTURE OF THE DISPLAY PARAMETER TECHNICAL DATA 08.2013 Ze
Bekrer B.IQ
2
B.IQ DESIGN Frameless KNX pushbutton 4 different Materials
Glass
■ Polarwhite ■ Black
Aluminium Plastic Stainless steel
08.2013 Ze
Bekrer B.IQ
3
B.IQ VERISONS The Berker B.IQ is available in different verions: 1gang 2gang 3gang 4gang 3gang with RTR 4gang with RTR 5gang with RTR
08.2013 Ze
Bekrer B.IQ
4
B.IQ DESIGN & VERSIONS
B.IQ push button 1- 4 gang
B.IQ push button with RTR and display 3 - 5gang
Uniform installation height
08.2013 Ze
Bekrer B.IQ
5
B.IQ DESIGN & VERSIONS
Uniform installation height
B.IQ push button with RTR and display 3gang (also 4gang and 5gang)
B.IQ push button 1gang 08.2013 Ze
Bekrer B.IQ
B.IQ push button 4gang
6
B.IQ 1- 4GANG STANDARD Productname: B.IQ Pushbutton, X-gang Order No:
08.2013 Ze
Bekrer B.IQ
7516 x0 9x
7
B.IQ 1- 4GANG STANDARD with anti-dismantling protection with blue operation LED and white status LEDs for switch, push-button, dimmer and shutter functions dimming / position value transmitter 1 byte extension unit for light scene pushbutton
08.2013 Ze
Bekrer B.IQ
8
B.IQ 1- 4GANG KOMFORT Productname: B.IQ Pushbutton, X-gang comfort Order No:
08.2013 Ze
Bekrer B.IQ
7516 x5 9x
9
B.IQ 1- 4GANG KOMFORT Standard functions plus: value transmitter for dimming, position, brightness and temperature values 1 and 2 byte cyclic transmission can also be started via switching object alarm telegram after disconnection from bus coupling unit 1 bit or 1 byte single and two push-button operation parameterisable one push-button operation for switching, pushing, shutters and dimming activation of second user level via object 08.2013 Ze
Bekrer B.IQ
10
B.IQ 3- 5 GANG WITH RTR Productname: B.IQ Pushbutton, X-gang with thermostat and display Order No:
08.2013 Ze
Bekrer B.IQ
7566 x5 9x
11
B.IQ 3- 5 GANG WITH RTR with anti-dismantling protection With blue operation LED and white status LEDs LC display with symbols and illumination, switchable via object display of operating mode, controller lockout, room/outside temperature, time (clock required) text display (ASCII-format) with 2 additional display buttons end customer display scope parameterisable
08.2013 Ze
Bekrer B.IQ
12
B.IQ 3- 5 GANG WITH RTR for switch, push-button, dimmer, shutter and room thermostat functions value transmitter for dimming, position, brightness and temperature values 1 and 2 byte extension unit for light scene pushbutton single and two push-button operation parameterisable one push-button operation for switching, pushing, shutters and dimming
08.2013 Ze
Bekrer B.IQ
13
B.IQ 3- 5 GANG WITH RTR area dimming shutter operation concept short-longshort and long-short parameterisable alarm telegram after disconnection from bus coupling unit 1 bit, 1 or 2 byte with room temperature timer and 2week timer functions For individual single room temperature control controller operating modes: comfort, standby, night and frost/heat protection mode
08.2013 Ze
Bekrer B.IQ
14
B.IQ 3- 5 GANG WITH RTR for heating and/or cooling mode with/without auxiliary step control parameter for heating / cooling unit pre-set temperature measurement via internal and/or external sensor with mean value formation separate window contact object indicator objects for heating and cooling with valve protection function object for controller status with flash-controller technology 08.2013 Ze
Bekrer B.IQ
15
DESIGN & VERSIONS CONSTRUCTION & DIMENSIONS STRUCTURE OF THE DISPLAY PARAMETER TECHNICAL DATA 08.2013 Ze
Bekrer B.IQ
16
B.IQ CONSTRUCTION & DIMENSIONS
08.2013 Ze
Bekrer B.IQ
Labelling field (optional)
Spacer plate for the display (only required if the labelling field is used)
Base plate with display
Transparent protective cover for the electronics (do not remove or paint over)
Design cover (only to be fitted once all installation work has been completed)
17
B.IQ CONSTRUCTION & DIMENSIONS
08.2013 Ze
Bekrer B.IQ
Base plate with display
Guide pins
Securing screws for base plate / bus coupling unit supporting ring.
User interface (PEI)
18
B.IQ CONSTRUCTION & DIMENSIONS Display / display buttons Labelling field
Function buttons / rocker switches
Status LEDs
Operating LED 08.2013 Ze
Bekrer B.IQ
19
B.IQ CONSTRUCTION & DIMENSIONS
08.2013 Ze
Bekrer B.IQ
20
DESIGN & VERSIONS CONSTRUCTION & DIMENSIONS STRUCTURE OF THE DISPLAY PARAMETER TECHNICAL DATA 08.2013 Ze
Bekrer B.IQ
21
B.IQ STRUCTURE OF THE DISPLAY
Lower values (left display button)
Frost / heat protection Comfort extension (“Frost / heat protection” operating mode)
Accept a change into a sub-menu
“Comfort” operating mode
Switch off room cooling in the event of condensation on the cooling unit
“Standby” operating mode
A change made to the required value using the display buttons
“Night” operating mode
Programming mode
Comfort extension (“Night” operating mode)
08.2013 Ze
Bekrer B.IQ
Operation of the display buttons or individual rockers or operation of the device locked
Timer active or control display in respective programming
Reserved for future developments Heating energy is supplied or control display in the programming Cooling energy is supplied or control display in the programming
Change the menu item (right display button) Raise the value (right display button)
22
DESIGN & VERSIONS CONSTRUCTION & DIMENSIONS STRUCTURE OF THE DISPLAY PARAMETER TECHNICAL DATA 08.2013 Ze
Bekrer B.IQ
23
B.IQ PARAMETER / ETS CONFIGUTATION The standard and the comfort B.IQ‘s can be configured with Parameters directly in the ETS. The B.IQ with Display and temperature control needs a plug-in which has to be installed. This is available with the Application on www.berker.com The next sheets will show the parametration of a RTR B.IQ
08.2013 Ze
Bekrer B.IQ
24
B.IQ PARAMETER / ETS CONFIGUTATION
08.2013 Ze
Bekrer B.IQ
25
B.IQ PARAMETER / ETS CONFIGUTATION яБо Gerneral settings
08.2013 Ze
Bekrer B.IQ
26
B.IQ PARAMETER / ETS CONFIGUTATION яБо Display
08.2013 Ze
Bekrer B.IQ
27
B.IQ PARAMETER / ETS CONFIGUTATION яБо Push button function
08.2013 Ze
Bekrer B.IQ
28
B.IQ PARAMETER / ETS CONFIGUTATION яБо Rocker / Push button function
08.2013 Ze
Bekrer B.IQ
29
B.IQ PARAMETER / ETS CONFIGUTATION яБо Status LED
08.2013 Ze
Bekrer B.IQ
30
B.IQ PARAMETER / ETS CONFIGUTATION яБо Addressing by drag & drop
08.2013 Ze
Bekrer B.IQ
31
B.IQ PARAMETER / ETS CONFIGUTATION яБо Addressing
08.2013 Ze
Bekrer B.IQ
32
B.IQ PARAMETER / ETS CONFIGUTATION яБо Room temperature regulation
08.2013 Ze
Bekrer B.IQ
33
B.IQ PARAMETER / ETS CONFIGUTATION яБо Room temperature regulation
08.2013 Ze
Bekrer B.IQ
34
B.IQ PARAMETER / ETS CONFIGUTATION яБо Temperature measuring
08.2013 Ze
Bekrer B.IQ
35
B.IQ PARAMETER / ETS CONFIGUTATION яБо Room temperature regulation
08.2013 Ze
Bekrer B.IQ
36
DESIGN & VERSIONS CONSTRUCTION & DIMENSIONS STRUCTURE OF THE DISPLAY PARAMETER TECHNICAL DATA 08.2013 Ze
Bekrer B.IQ
37
B.IQ TECHNICAL DATA Supply
Voltage (via bus line):
21–32 V DC
Power consumption (via bus line):
typically 360 mW
Rockers (buttons)
3-5 (6-10)
Graphics display with 2 display buttons
Two lines with symbol bar
Measuring range
0° C to 40° C
Resolution
0.1 K
Air humidity
0% to 95% (non-condensing)
Resolution
1 minute
Gang variation
max. 8 minutes a day (use external clock!; update every hour over the bus)
Connections
Flush-mounted bus coupling unit plus (7504 00 03)
User interface: 2 x 5-pin male connector
Index of protection
IP 20
Ambient temperature range
Mode
-5 to +45°C
Storage / transportation
-20 to +60 °C (storage at over +45°C will reduce the working life)
Controls and displays
Internal temperature sensor
Internal clock
Assembly
Plug into flush-mounted bus coupling unit
Mounting orientation
any
Dimensions (W x H x D)
depending on design
08.2013 Ze
Bekrer B.IQ
see dimensional drawings 38
Thanks for your attention
08.2013 Ze
Bekrer B.IQ
39