[Title will be auto-generated]

Page 1

IP-CONTROL TABLE OF CONTENT INDEX

INDEX

1. Product presentation

5. Tips&Tools

1.

1. 2. 3. 4.

Overview

2. Start-up 1.

Start-up

Network configuration Update-Tool ETS 4 Application Group address import and export

3. Editors 1. 2. 3.

Visualisationeditor Jobeditor Systemtool

4. Application 1. 2. 3. 4. 5. 6. 7. 8. 07.2012

Visualisation Create a project Create a switch function Create a camera function Multiroomcontrol with IP-Control IP-Control Mobile devices Create a Master page Create a Embedded Flip page BERKER TRAINING

IP-CONTROL RELEASE 5

1


IP-CONTROL


PRODUCT PRESENTATION START-UP EDITORS APPLICATION TIPS & TOOLS 07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

3


IP-CONTROL OVERVIEW  Product:

IP-CONTROL

 Ordernumber: 7571 00 04

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

4


IP-CONTROL OVERVIEW FUNCTION OVERVIEW  Visualisation (50 different Users, maximum of 15 Users at the same time)  NEW: KNX Net-IP Access (KNX ETS commissioning over IP)

 System connection over IP (Function similar a KNX-line coupler)  Visualisation of network cameras

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

5


IP-CONTROL OVERVIEW FUNCTION OVERVIEW  Automation-Jobs: Logic gates, switch on-off delay time, staircase light function, multiplexer, comparator, math functions  Weekly timer, Yearly timer  Date & time transmitter  E-Mail function  Scene function  Hysteresis and threshold switches 

 The number of logic and automation jobs is not absolutely limited. Recomment not more than 200 jobs for optimal working. 07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

6


IP-CONTROL OVERVIEW FUNCTION OVERVIEW  Automation-Jobs: 

Job to control multiroom audio devices (Logitech Squeezebox)

 Independent visualisation for mobile

devices

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

7


IP-CONTROL OVERVIEW IP-CONTROL NEW FIRMWARE VERSION 1.5 (R05)  New type of visualisation for tablets (e.g. iPad or Android Tablets)  Existing visualisation on IP-Control  Java based visualisation in normal browser– The “classic” IP-Control visualisation  HTML based visualisation for mobile devices (IP-Control Mobile) since Release 03

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

8


IP-CONTROL OVERVIEW IP-CONTROL SINCE VERSION 1.4 (LATEST VERSION 1.5)  NEW: IP-CONTROL-TABLET Special visualisation for mobile devices with high resolution display and HTML / AJAX technoligy (e.g. iPad, Android Tablets)  IP-Control Tablet provides the possibility to take over the “normal” visualisation from IP-Control Restriction:  Free components are not supported by IP-Control Tablet , only elements of the standard library are supported

 Selectable at startup page

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

9


PRODUCT PRESENTATION START-UP EDITORS APPLICATION TIPS & TOOLS 07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

10


IP-CONTROL START-UP REQUIREMENTS OF IP-CONTROL  Network connection (network cable or network components (e.g. Switch))  KNX bus voltage  10 - 30 V DC external power supply

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

11


IP-CONTROL START-UP  non ETS application (Visualisiation and programming on browser)  Status LED‘s  Power - LED

(Operating status)

 BMX - LED

(IP-Control kernel-mode)

 KNX -

(KNX bus)

LED

 Without function  LAN -

07.2012

BERKER TRAINING

LED

IP-CONTROL RELEASE 5

(LAN activity)

12


IP-CONTROL START-UP REQUIREMENTS OF IP-CONTROL  Current webbrowser (e.g. Internet Explorer, Firefox, Netzcape etc.)  JAVA Runtime Engine Version 1.6 or higher (Download http://www.java.com

07.2012

BERKER TRAINING

Oracle)

IP-CONTROL RELEASE 5

13


IP-CONTROL START-UP VERSION CHECK JAVA  the JAVA-Icon could be found on system control of Windows  Application info provides the version number (e.g. 1.6.23)

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

14


IP-CONTROL START-UP SETTINGS ON JAVA  On tab „General“ – Temporarily Internet-Files click on „Settings“  Remove the mark „keep temporary files on my computer“

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

15


IP-CONTROL START-UP CALL UP THE IP-CONTROL IN BROWSER  Call up the „Start page“ of the IP-Control with device IP-address

Type in IP-adress of IP-Control (e.g.: http://192.168.1.10)

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

16


IP-CONTROL START-UP ERROR MESSAGE ON CALL UP THE „START PAGE“  Please check  Correct IP-address (e.g: http://192.168.1.10)  Connection to network  IP-address of your computer is in the correct ip-address range

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

17


IP-CONTROL START-UP VALIDATION OF IP-SETTINGS  To check the ip-settings please use Discovery Tool  Discovery Tool located on IP Control CD  Discovery Tool is a Java tool and directly executable (no need of installation)

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

18


IP-CONTROL START-UP VALIDATION OF IP-SETTINGS  Discovery Tool

Available IP-Controls green = available yellow = other network segment IP address of the IP-Control Open browser with IP-Control start page

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

19


IP-CONTROL START-UP CALL UP IP-CONTROL IN BROWSER  Call up the „Start page“ using the ip-address of the device

IP-adress of IP-Control (http://192.168.1.10)

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

20


IP-CONTROL START-UP POSSIBLE SECURITY WARNINGS OF OPERATING SYSTEM  Security warning of operation system on first call up  Choose „Run“ or „Don`t block again“

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

21


IP-CONTROL START-UP STARTING THE VISUALISATION EDITOR  Choose the button „Editor“ and you will get the user authentication box

Username: Password:

admin* berker*

* delivery default settings 07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

22


IP-CONTROL START-UP VISUALISATION EDITOR  Editor is started and visualisation can be arranged

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

23


PRODUCTPRESENTATION START-UP EDITORS APPLICATION TIPS & TOOLS 07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

24


IP-CONTROL EDITORS CHOOSING THE FUNCTION  3 different choices are available  Visualisierung = starting the existing visualisation  Editor = changing existing / creating new visualisations  System = changing the system settings

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

25


VISUALISATION EDITOR


IP-CONTROL EDITORS VISUALISATION EDITOR  The design and functions of the visualisation will be configured on editor  Configuration of the project by using the existing menu bar and visualisation elements  Setttings of background images, images and page sizes  Setup user management  Import of group adresses and images  General settings such as for e.g. IP-Control clock and display of KNX group addresses

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

27


IP-CONTROL EDITORS VISUALISATION EDITOR  Range of functions compared to previous version  Backup-dialog on end of task  Visu Live Mode possible on editor  Image database included on editor (image import via drag & drop or image-transfer)  Import of group addresses included on editor  Free allocation of working surface (simular to ETS4)  Supporting new visualisation variants (mobile devices)

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

28


IP-CONTROL EDITORS VISUALISATION EDITOR  Multi-part view for effective work

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

29


IP-CONTROL EDITORS VISUALISATION EDITOR  General functions like e.g. Save – New page – New project

General functions

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

30


IP-CONTROL EDITORS VISUALISATION EDITOR  Structure of projects such as e.g. project compilation – pages – master pages

Project struktur

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

31


IP-CONTROL EDITORS VISUALISATION EDITOR  Elements for functions such as e.g. Switching – dimming – value display

elements

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

32


IP-CONTROL EDITORS VISUALISATION EDITOR  Configuration of active page e.g. Size – background - colour

Parameters

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

33


IP-CONTROL EDITORS  The visualisation editor contains elements for following functions  switch, push and release function  binary status  dim, blind control  value transmitter, value display  temperature indication and – adjustment  text display  time and date displays  camera integration  fault message  diagram  RSS feeds  … 07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

34


IP-CONTROL EDITORS VISUALISATION EDITOR-IMAGEPOOL  To use images in IP-Control , they have to be imported first  To import images use menu „Extras – image transfer“

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

35


IP-CONTROL EDITORS VISUALISATION EDITOR – IMAGE POOL  Upload images

Choose image file

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

36


IP-CONTROL EDITORS VISUALISATION EDITOR – IMAGE POOL  Upload images

Select button to upload the image

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

37


JOB EDITOR


IP-CONTROL EDITORS JOB EDITOR  The Job editor provides you with services (jobs)  Services are created and parameterized  Jobs are tasks performed by the IP-Control  Jobs are e.g.  Logic gates  Light scenes  Date and time elements  Week timer  Media control  etc.

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

39


IP-CONTROL EDITORS JOB EDITOR  Start

Start Job editor

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

40


IP-CONTROL EDITORS JOB EDITOR  Overview

Job-Editor starten

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

41


SYSTEM TOOL


IP-CONTROL EDITORS SYSTEM TOOL  Call up System tool

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

43


IP-CONTROL EDITORS SETTINGS SYSTEM TOOL  Fill in IP-Control string or charcter string (e.g. Aag6F4)  Character string is located on manual and on back of the device

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

44


IP-CONTROL EDITORS SETTINGS SYSTEM TOOL  Several possibilities of settings  User administration  Configuration  Start page  Backup / restore

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

45


IP-CONTROL EDITORS SETTINGS SYSTEM TOOL  Configuration  Setup network ■ IP address 192.168.1.10 ■ Subnetmask. 255.255.255.0 ■ Default gateway for connection to internet ■ DNS Server normally the same as default gateway ■ Time server configuration to synchronize with internet time server (Net Time Protocol)

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

sample of settings

46


IP-CONTROL EDITORS SETTINGS SYSTEM TOOL  Configuration  Set up the name „IP-Control building 1“  Set up the physical address ■ Phy. address

1.1.50

sample of settings

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

47


PRODUCTPRESENTATION START-UP EDITORS APPLICATION TIPS & TOOLS 07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

48


VISUALISATION


IP-CONTROL APPLICATION START THE VISUALISATION

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

50


IP-CONTROL APPLICATION START THE VISUALISATION  Visu Window  Visualisation starts in seperate browser window

 Visu Browser  Visualisation starts in actual browser window

 IP-Control Tablet  New surface optimized for tabletPC‘s or smartphones

 IP-Control Mobile  Universal surface for several devices with different operating systems 07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

51


IP-CONTROL APPLICATION START THE VISUALISATION  Visu Window  Visualisation starts in seperate browser window

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

52


IP-CONTROL APPLICATION START THE VISUALISATION  Visu Browser  Visualisation starts in actual browser window

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

53


IP-CONTROL APPLICATION START THE VISUALISATION  IP-Control Tablet  New surface optimized for tabletPC‘s or smartphones

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

54


IP-CONTROL APPLICATION START THE VISUALISATION  IP-Control Mobile  Universell surface for several devices with different operating systems  Predefined functions with default symbols

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

55


CREATE A PROJECT


IP-CONTROL APPLICATION CREATE A PROJECT  1st step : Creating a new project

Enter name of project

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

57


IP-CONTROL APPLICATION CREATE A NEW PAGE  2nd step : Create a new page

Enter name of page

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

58


CREATE A SWITCH FUNCTION


IP-CONTROL APPLICATION CREATE A SWITCH FUNCTION  1st step : Creat a switch function Symbol of switch function

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

60


IP-CONTROL APPLICATION CREATE A SWITCH FUNCTION  2nd step : Creat a switch function

Icon of switch function Configuration part of element: Possibility of positioning the object and connecting the output to a group address

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

61


IP-CONTROL APPLICATION CREATE A SWITCH FUNCTION  3rd step : Connect to group address

To select group address double click the line

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

62


IP-CONTROL APPLICATION CREATE A SWITCH FUNCTION  4th step : Connect to group address

Confirm

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

63


IP-CONTROL APPLICATION CREATE A SWITCH FUNCTION  5th step : Connect to group address /check

Combined group address

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

64


IP-CONTROL APPLICATION CREATE A SWITCH FUNCTION  6th step : Test the function in live mode

Start live modus

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

65


IP-CONTROL APPLICATION CREATE A SWITCH FUNCTION  7th step : Test the function in live modus

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

66


IP-CONTROL APPLICATION CREATE A SWITCH FUNCTION  7th step : Test the function in live mode

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

67


CREATE A CAMERA FUNCTION


IP-CONTROL APPLICATION CREATE A CAMERA FUNCTION  1st step : Insert camera function

Insert Camera

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

69


IP-CONTROL APPLICATION CREATE A CAMERA FUNCTION  2nd step : Configure URL of camera

2 options of using network cameras 1st variante MJPEG STREAM 2nd variante static image In the URL field, enter the full network path to the image memory of the camera, preceded by HTTP:// (e.g. HTTP://192.168.1.2/record/current.jpg) 07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

70


IP-CONTROL APPLICATION CREATE A CAMERA FUNCTION  3rd step : Enter description of camera

Description of camera(name)

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

71


IP-CONTROL APPLICATION CREATE A CAMERA FUNCTION  4th step: Configure password

If necessary, enter user and password

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

72


IP-CONTROL ANWENDUNGEN CREATE A CAMERA FUNCTION  5th step : Test the function in live mode

Start live modus

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

73


IP-CONTROL APPLICATION CREATE A CAMERA FUNCTION  6th step : Test the function in live mode

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

74


IP-CONTROL APPLICATION CREATE A CAMERA FUNCTION  7th step : Test the function in live mode

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

75


CREATE A MASTER PAGE


IP-CONTROL APPLICATION CREATE A MASTER PAGE  By using Master pages recurrent pages can be added automatically  Possible to define more Master pages  E.g. design, function and textparts could be defined

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

77


IP-CONTROL APPLICATION CREATE A MASTER PAGE  A new master page will be inserted in the structure of the project  The new Master page can be configured Name of page could be changed  Design could be changed 

■ Background colour / background image ■ Functions

01.2012

BERKER SCHULUNG

IP-CONTROL RELEASE 5

78


IP-CONTROL APPLICATION CREATE A MASTER PAGE  Inside configuration of normal page select the Master page  All parameters of the Master page will be integrated on this page

01.2012

BERKER SCHULUNG

IP-CONTROL RELEASE 5

79


CREATE AN EMBEDDED FLIP PAGE


IP-CONTROL APPLICATION CREATE A FLIP PAGE  Flip pages are embeded Pages with scroll function ( flipping) on a page (like frames on websites)  More functions could be placed onto a sub area  It`s possible to create multible flip pages  e.g. Navigation, control functions and text areas could be defined

01.2012

BERKER SCHULUNG

IP-CONTROL RELEASE 5

81


IP-CONTROL APPLICATION CREATE A FLIP PAGE  A new Flip page will be inserted in the structure of the project  The new Flip page can be configured Name of page could be changed  Design could be changed 

■ Background colour / background image ■ Functions

01.2012

BERKER SCHULUNG

IP-CONTROL RELEASE 5

82


IP-CONTROL APPLICATION CREATE A FLIP PAGE  Setup the size of Flip page  Setup number of segments  Setup the start segment

01.2012

BERKER SCHULUNG

IP-CONTROL RELEASE 5

83


IP-CONTROL APPLICATION INTEGREATE A FLIP PAGE  Embedded on page  Setup number of segments  Setup the start segment

01.2012

BERKER SCHULUNG

IP-CONTROL RELEASE 5

84


MULTIROOM CONTROL WITH IP-CONTROL


IP-CONTROL APPLICATION  Classical music media like CD are increasingly substituted by MP3 files  Internet music stores and possibilities to readout CDs are used to build up central MP3 collections on servers  Manufacturers of consumer electronics offer streaming-clients, which reproduce the centrally stored music optionally in different rooms  Normally the user handles the devices through special user interfaces, which belong to the electronics

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

86


IP-CONTROL APPLICATION  Berker has developed a special solution for multiroom audio control based on IP-Control and Logitech Squeeze Boxes  This solution provides an easy way to realise a smart multiroom environment  IP-Control is the interface between the KNX devices and the multiroom electronics

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

87


IP-CONTROL APPLICATION

 IP-Control is the interface between the KNX devices and the multiroom electronics KNX

IP Zone 1

Zone 2 IP

MP3 collection

Internet Radio 07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

88


IP-CONTROL APPLICATION  Squeezeboxes are streaming clients for MP3 files located on the SqueezeServer or for internet radio stations.  SqeezeServer manages the MP3 files and internet radio stations in playlists.

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

89


IP-CONTROL APPLICATION  Essential components for this solution:  PC for the SqueezeServer software  IP-Control R2 or higher  Logitech Squeezebox per each zone  Optional a B.IQ RTR per zone or another multifunctional KNX switch  Optional a Master Control for the central handling or a PC for the IPControl visualisation  For the SqueezeServer you need: ■ A plugin, which is located on the IP-Control CD or is available on the internet at Berker download area ■ Further you need a xPL hub software, which is freely available on the internet

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

90


IP-CONTROL APPLICATION

optional

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

91


IP-CONTROL APPLICATION  The job Squeezebox-Control (SBC) of the IP-Control provides a KNX interface for the control of Squeezeboxes. With this job KNX-devices can control Squeezeboxes with following functions:  Zone on/off, mute on/off (pause/play)  Volume control with feedback of the current volume as EIS 15 (14 bytes) ASCII text and EIS 6 (1 byte) value, e.g. „Volume 45%“ in the text display of the B.IQ RTR or as bargraph in the MC or the visualisation  Selection of playlists or titles  Display of playlist names and track names as ASCII text

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

92


IP-CONTROL APPLICATION  With this job KNX-devices can control Squeezeboxes with following functions:  Display of additional track information like artist or album name as text in the MC or the visualisation  Display of a 4-row, scrollable view of all playlists for the directed selection of a playlist in the MC or visualisation by name  Adjustment of limitations for the volume in each zone by the visualisation or the MC

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

93


IP-CONTROL APPLICATION EXAMPLE FOR AN USER INTERFACE

14 Byte ASCII Text

Zone on/off (toggle) Quieter (darker) Playlist/Track (long/short)

07.2012

BERKER TRAINING

Mute on/off (toggle) Louder (brighter) Playlist/Track (long/short)

IP-CONTROL RELEASE 5

94


IP-CONTROL APPLICATION  Job Name: Required entry  Gate Group Adresses: If a group address is connected, the job is only active by an "1” (1bit group adress)  SB name: The name of the squeezebox which is to be controlled (The entry must be on par with the squeezebox server entry for this squeezebox)

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

95


IP-CONTROL APPLICATION  Absolute limit of maximum volume of the squeezebox in % (default 100)  Absolute limit of minimal volume of the squeezebox in % (default 0)  Gradual dimming of the volume specified step width (default 2)  Output of the current volume to display  Output of the current volume to display  Setting volume per value (1byte) 07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

96


IP-CONTROL APPLICATION  Switch on / off the zone (squeezebox)  Play / Pause track  Track next / previous  Forward / rewind (search in track, High Speed)  Seek width (speed….)  Playlist next / previous

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

97


IP-CONTROL APPLICATION  Diplay message Output:  Object to transmit text information on a single-line display (rotating display)

 Text bypass input:  Object to fade in of further texts from an external source of the KNX, e.g. Alarms (s.a. B. IQ info text)

 Reset textdisplay:  Object to reset the alarm line of text in the B.IQ displays. When squeezebox turned off, the alarm function of the B. IQ display will be reset and the normal content of the display is again represented.

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

98


IP-CONTROL APPLICATION  Reset invert:  Setting this flag the reset of the textdisplay will be inverted

 Reset on Zone:  Setting this flag will reset the text display when squeezebox is switched off

 Reset on mute:  Setting this flag will reset the text display when squeezebox is muted

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

99


IP-CONTROL APPLICATION  Display „No Playlist“:  When marked it will show „No Playlist“ if there is no playlist defined

 Display „No Title“:  When marked it will show „No Title“ if there is no title defined

 Time x:  Time in seconds after the display set back to the default display

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

100


IP-CONTROL APPLICATION  Object for text output of current playlist  Object for text output of the line x in the playlist selection  Object for text output of current title  Object for text output of current album  Object for text output of current artist

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

101


IP-CONTROL APPLICATION  Object to control the previous or next page in the playlist selection (next = 1, the next / previous 4 playlist names will be displayed)  Object to select the playlist from the playlist selection (values 0-3 for the selection of lines 1-4)

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

102


IP-CONTROL APPLICATION

Command code : with one group address all the functions can be triggered by value (1 byte)

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

103


IP-CONTROL APPLICATION EXAMPLE FOR A PAGE Act. Info

act. title

Playlist

ZONE

act. artist

Playlist

75 %

act. album

Playlist Playlist

Volume limit 25 25 07.2012

50

75 75 BERKER TRAINING

IP-CONTROL RELEASE 5

104


IP-CONTROL MOBILE DEVICES


IP-CONTROL APPLICATION IP-CONTROL MOBILE DEVICES  Functions: Direct access to the IP-Control  No additional devices are necessary  Integrated „user interface for mobile devices“  License cost free  Smart phones 

IP

KNX 07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

106


IP-CONTROL APPLICATION  Controlling a KNX – System via mobile devices: 

Operation with:

Smart phone Mobile phone PDA

 Functions e.g. switching, dimming and shutter control

07.2012

BERKER TRAINING

IP

IP-CONTROL RELEASE 5

107


IP-CONTROL APPLICATION OPERATION OF A LIGHT

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

108


IP-CONTROL APPLICATION OPERATION OF A SHUTTER

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

109


IP-CONTROL APPLICATION ADJUSTMENT OF THE SETPOINT TEMPERATURE

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

110


IP-CONTROL APPLICATION MULTIMEDIA CONTROL

KNX

IP Zone 1 IP Internet Radio

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

MP3 Sammlung

IP

WLAN

111


IP-CONTROL APPLICATION  The IP-Control mobile devices surface is to be used with a mobile browser:  http://192.168.1.10/ipcm  Default user: ipcm  Default password:(no password )

 Passwords can be setup in Editor  Security Settings: Security Settings

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

112


IP-CONTROL APPLICATION SECURITY SETTINGS Passwords can be setup in Editor  Security Settings: 1.Mark Checkbox : User

1.

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

113


IP-CONTROL APPLICATION SECURITY SETTINGS 2. Click New User 3. Insert a unique username

2.

3.

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

114


IP-CONTROL APPLICATION SECURITY SETTINGS 4. Setup Pasword 5. Mark Checkbox IP-Control Mobile 4.

5. 07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

115


IP-CONTROL APPLICATION  The visualisation is optimized for mobile devices  Visualisation looks similar on smart phone, PDA or mobile phone  Size of the visualisation depends on the resolution of the screen

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

116


IP-CONTROL APPLICATION  Operation is performed by using pointer or touchscreen operation  E.g.: Operation on groundfloor changes the visualisation to the surface of the floor: Livingroom  Kitchen  Workroom  Restroom 

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

117


IP-CONTROL APPLICATION  Next step shows the visualisation livingroom

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

118


IP-CONTROL APPLICATION  Operation of the corresponding lamp with colored status feedback Status O  Status I 

07.2012

= Off = On

BERKER TRAINING

IP-CONTROL RELEASE 5

119


IP-CONTROL APPLICATION  Example to adjust the setpoint temperature in a room with current temperature Current temperature  Setpoint temperature  Change the temperature = Setpoint ( +,-) 

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

120


IP-CONTROL APPLICATION  Structure of the operation: Step 1 Groundfloor Step 2 Livingroom Step 3 Livingroom Light Ceiling Step 4 Funktion ( ON / OFF)

 Structure is adjusted on IP-Control  Important: Only one project „IPControl mobile devices“ can be defined on IP-Control!

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

121


IP-CONTROL APPLICATION  After first function test, you can create a bookmark on the home screen of iPhone or iPod.

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

122


IP-CONTROL APPLICATION START IP-CONTROL MOBILE EDITOR

Start the editor

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

123


IP-CONTROL APPLICATION EDITOR - GENERAL

Insert and settings via right mouse click.

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

124


IP-CONTROL APPLICATION EDITOR - GENERAL

Insert new elements

Reload the Editor Save Changes

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

125


IP-CONTROL APPLICATION EDITOR – ADD NEW BUILDING PARTS

Add new folder to create a new part of the building

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

126


IP-CONTROL APPLICATION EDITOR – ADD FUNCTION „SWITCH“

Add switch function

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

127


IP-CONTROL APPLICATION EDITOR – ADD FUNCTION „SWITCH“

Enter the description

connect to group address

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

128


IP-CONTROL APPLICATION MORE FEATURES More Features e.g.:  Camera  Temperature  Value  Shutter  List (Playlist)  Dyn. Playlist  MediaControl

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

129


PRODUCTPRESENTATION START-UP EDITORS APPLICATION TIPS & TOOLS 07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

130


NETWORK CONFIGURATION


IP-CONTROL TIPS & TOOLS NETWORK CONFIGURATION Settings for IP address of PC Start – Settings – Control panel Select network connections LAN – Select connection with double click

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

132


IP-CONTROL TIPS & TOOLS NETWORK CONFIGURATION Select button „Properties“

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

133


IP-CONTROL TIPS & TOOLS NETWORK CONFIGURATION Select Internet Protocol (TCP/IP) Click Properties

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

134


IP-CONTROL TIPS & TOOLS NETWORK CONFIGURATION Select "Use following IP address" Enter IP address

192.168.1.2

Subnet mask

255.255.255.0

Default gateway is not required for local commissioning Confirm settings with OK

Note: These are examples, other addresses and address ranges are possible in practice! 07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

135


UPDATE-TOOL


IP-CONTROL TIPS & TOOLS UPDATE-TOOL  Advantages for customers:  Update-package online avaible  The update can be applied on-site without the necessity of sending in  Short reaction time to do an update  The update-tool is self-descriptive

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

137


IP-CONTROL TIPS & TOOLS UPDATE-PACKAGE AND NEW FIRMWARE IP-CONTROL 1.4 (R4) ONLY FOR IP-CONROL OLDER THAN R4  The update-package contains following parts:  Update-Tool  Firmware R04  Documentation R04

 Since WK3 2011 IP-Control will be delivered with firmware 1.4 (R04)  The update-package is available in download area

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

138


IP-CONTROL TIPS & TOOLS FIRMWARE UPDATE  Using the IP-Control update tool, it is possible to flash a new firmware into the devive.  The update tool itselfs is a Java based programm, and works on several operating systems.  During this procedure, it is extremely important to read and observe the following information carefully  If the update procedure fails, IP Control might have to be returned to the manufacturer.

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

139


IP-CONTROL TIPS & TOOLS FIRMWARE UPDATE  IPC_UpdateTool:  The Update Tool starts on clicking the .exe-file. There is no need of installation.

 fw_ipc-1.4.0 (R04):  Choose firmware for IP-Control, Release 4 (updated 01-2011) to do an update

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

140


IP-CONTROL TIPS & TOOLS IMPORTANT MEASURES:  First create a current backup of your project  IP Control is reset to the factory settings by an update, the project data are therefore lost.  Please note: the passwords of the visualisation users are not copied during recovery.  Please note that you can reenter these after the update procedure and project recovery.

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

141


IP-CONTROL TIPS & TOOLS IMPORTANT MEASURES:  For an update you need the Update Tool and the desired firmware image. This is delivered as a zip file together with a checksum file in order to check the correct transfer and avoid any errors. Both of these can be downloaded in the download area at http://www.berker.de. Both files have to be unzipped in a directory.  We strongly recommend that you carry out the firmware update only within sight of the IP Control. IP Control reproduces a status feedback via its five LEDs during the update procedure. A firmware update via one or more networks is not possible, they must be in the same physical and logical network as the IP Control.

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

142


IP-CONTROL TIPS & TOOLS IMPORTANT MEASURES:  If you operate your IP Control with DHCP, you should switch this off and assign IP Control a fixed IP address.  For the update you need the IP Control string and password of the user "admin".  During the firmware update, IP Control is reset to the factory settings, i.e. it retains its old IP address xxx.xxx.xxx.xxx but has been overwritten with the password "berker".  The entire update procedure lasts approximately 15 min.

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

143


IP-CONTROL TIPS & TOOLS PROCEDURE  If all the necessary measures have been made, please proceed as follows:  Switch off all security software and/or firewall for the update procedure since this might disturb the communication. (The communication takes place on the UDP port 1735).  Make sure of not using any other network connections during the disabling of security software and/or firewall.  Don`t forget to reactivate the security software and/or firewall after finishing the update procedure

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

144


IP-CONTROL TIPS & TOOLS PROCEDURE  Creating backup  If you have not already done so, make a backup of the current project.

 Opening update tool  Open the update tool. All relevant information and tips are summarised in the help text of the update tool.

 Selecting IP Control  Select the desired IP Control in the left column and enter the IP Control string and admin password on the right.

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

145


IP-CONTROL TIPS & TOOLS PROCEDURE  Select the desired IP Control in the left column and enter the IP Control string and admin password on the right. If the device is in the same network, the text has a green background, if it is not in the same network, it has a yellow background. Below the display is a display of the necessary IP Control parameters. Experienced IP Control users will know this from the Discovery Tool.  If several IP Control are installed, the IP Control can be identified visually by means of the "LED Test".

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

146


IP-CONTROL TIPS & TOOLS PROCEDURE  In the status window below, you will be shown which actions are being executed. If the IP Control system is already installed with a rescue system, it will be restarted with this. If the device has not yet been equipped with the system, this step will first be executed.  The selected device first appears in the list of the IP Control with a blue background. If the rescue mode is active, it appears there with a green background and with a red cross. On the device itself, the power LED lights up orange at this moment, the LAN LED flashes depending on the network traffic and the BMX LED flashes red.

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

147


IP-CONTROL TIPS & TOOLS PROCEDURE  Selecting firmware file  If the IP Control is in rescue mode, the view in the Update Tool changes and the request to select the correct firmware file appears on the right.  When opening the image file, the Update Tool checks whether the firmware image was transferred correctly during download by means of the md5-checksum included.  The update procedure can now be started by pressing the button "Start IP Control Update". After the firmware file is loaded into the device, the IP Control is busy checking the file for approx. 5 min. Now the BMX and EIB LED flash red simultaneously.  After successful checking, the installation begins. This procedure takes approx. 5 minutes again. During this time, the three middle LEDs flash red.

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

148


IP-CONTROL TIPS & TOOLS PROCEDURE  IP Control should not be disconnected from the power supply under any circumstances during the entire procedure. This can cause irreparable damage to the software, the device must be returned.  Factory settings  If the firmware is installed, the IP Control restarts. Afterwards, it is in the network with the factory settings. It therefore has the IP address assigned by you xxx.xxx.xxx.xxx but the password for the user "admin" is now "berker".

 Recovering backup file  Load your current backup into the device. All the settings are recovered, and the device restarts. Afterwards, it is available with all known settings but new firmware.

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

149


IP-CONTROL TIPS & TOOLS PROCEDURE  Please note that the backup file does not contain any information about the IP address settings. During the backup, only the port settings are saved but not the IP address settings (except for NTP timeserver)!  Recovering user administration  The user passwords must be reentered so that the user login on the Visualisation works perfectly again. Afterwards, the project must be saved once again.  During the recovery of your project file, please bear in mind that no projects from newer firmware versions may be loaded into older versions.

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

150


ETS 4 APPLICATION


IP-CONTROL TIPS & TOOLS IP-CONTROL AND ETS 4  There is no ETS application for the IP control, and this means that it cannot be inserted directly into the ETS project.  Insert a dummy device into the project to ensure that the physical address is reserved and so that filter tables can be correctly generated.

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

152


IP-CONTROL TIPS & TOOLS IP-CONTROL AND ETS 4  All group addresses must be connected to the dummy application  Important: Have a look to the data types (e.g. switch = 1 Bit)  ETS 4 automatic generates the filter tables (Couplers should be programmed when you finished your project!)

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

153


GROUP ADDRESS EXPORT AND IMPORT


IP-CONTROL TIPS & TOOLS IMPORT OF GROUP ADDRESSES  Start the export of group addresses

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

155


IP-CONTROL TIPS & TOOLS OPC SERVER EXPORT  Save the file with the name „training “

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

156


IP-CONTROL TIPS & TOOLS OPC SERVER EXPORT  Check if files are avaible

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

157


IP-CONTROL TIPS & TOOLS ARRANGE GROUP ADDRESSES IN IP-CONTROL  Import group addresses in editor

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

158


IP-CONTROL TIPS & TOOLS ARRANGE GROUP ADDRESSES IN IP-CONTROL  Import group addresses in editor

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

159


IP-CONTROL TIPS & TOOLS ARRANGE GROUP ADDRESSES IN IP-CONTROL  Choose file, the group adresses will be imported automaticly

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

160


IP-CONTROL TIPS & TOOLS ARRANGE GROUP ADDRESSES IN IP-CONTROL  Merge new group addresses

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

161


IP-CONTROL TIPS & TOOLS ARRANGE GROUP ADDRESSES IN IP-CONTROL  Choose „Open ESF File“

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

162


IP-CONTROL TIPS & TOOLS ARRANGE GROUP ADDRESSES IN IP-CONTROL  Select file

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

163


IP-CONTROL TIPS & TOOLS ARRANGE GROUP ADDRESSES IN IP-CONTROL  If deviant , select codepage

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

164


IP-CONTROL TIPS & TOOLS ARRANGE GROUP ADDRESSES IN IP-CONTROL  Select group addresses for import

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

165


IP-CONTROL TIPS & TOOLS ARRANGE GROUP ADDRESSES IN IP-CONTROL  Selected group addresses with a minus will be deleted !

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

166


IP-CONTROL TIPS & TOOLS ARRANGE GROUP ADDRESSES IN IP-CONTROL  Selected group addresses with a plus will be added!

07.2012

BERKER TRAINING

IP-CONTROL RELEASE 5

167


IP-CONTROL BERKER TRAINING

IP-CONTROL RELEASE 5

168


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.