Contents
Timer
Timer
Timer
BT-SERIES – overview
D.2
BT-SERIES – Timer
D.4
MCZ-SERIES – Timer
D.8
DK-SERIES – Timer
D.9
D
D.1
BT-SERIES – overview
Timer
Installation timer
Electronic timer from the BT product range offer ideal solutions for industrial applications.
Terminal Arrangement Connection of the timer Terminal Arrangement � � BTM-Z BTM-S BTM-Z A1 A1
15
15
B1
BTM-S
B1
A1 A1
The BT product range provides the following functions:
15
15
BTMF-S/BTR-S BTMF-Z/BTR-Z BTTT-S BTMF-S/BTR-S BTTT-Z BTMF-Z/BTR-Z L BTTT-S BTTT-Z L A1 15 A1
B1
15
A1
B1
A1
15
15
L
D
• Pick-up delay (BTR) • Pulse emitter (BTTT) • Multifunction with control input (BTM) • Multifunction without control input (BTMF) • Star-delta change-over
15
15
15 18 18
16
16 18
18
15
L
15
16
16 A2
A2
(DIN notation) (DIN notation)
15
15 18
16
18
16 18
16
18
16
15 18
18
A2
16
16
A2 (see note 1) (see note 1)
18 18
16
16
18
16
18
16 18
16
18
16
A2
A2
A2
A2
(DIN notation) (DIN notation)
(see note 1) (see note 1)
Time ranges and power supplies for timer Using the central knob, you can select the functions of the modules precisely over either 4 or 8 time ranges. The multi-voltage supply voltage range offers a wide bandwidth for industrial use (see technical data).
D.2
Note: 1. DC supply voltage does not require the designation of polarity. Note: 1. Pole numbers are not necessary for DC voltage supply. Note: 1. DC supply voltage does not require the designation of polarity. because it offers multiple operating modes and is different from the d 2. The contact symbol for the H3DS is indicated with contact symbol for conventional timers. for the H3DS is indicated with because it offers multiple operating modes and is different from the delaye 2. The contact contact for conventional 2. Thetimers. contact symbol of BTM is marked with as it
provides serveral operating modes and differs from the delayed contacts of conventional timer.
Timer
BT-SERIES – overview
Time ranges Display of time scale 0.1 s
Time ranges 0.1 to 1.2 s
1s 0.1 min 1 min 0.1 h 1h 10 h
1 to 12 s 0.1 to 1.2 min 1 to 12 min 0.1 to 1.2 h 1 to 12 h 10 to 120 h
Note: If the rotary knob for time adjustment is set to “0”, the output will be switched without delay.
Choosing the time range
D Dimensions
The time range is chosen by turning the rotary switch for the ON-time scale and OFF-time scale. The time scales are visible in the display to the left of the rotary switch in the following order: 0.1 s, 1 s, 0.1 m, 1 m, 0.1 h, 1 h.
73
80
45
Note: The time scales “1 s” and “0.1 h” are given twice. Both adjustments represent the same time scale.
68
44
Locking/unlocking of selectors and time setting dial The rotary switches for the ON/OFF time adjustment and the option selector for the time scale can be locked with the locking key. This pen-style special tool is available separately. To lock either rotary switches or the option selector, simply insert the locking key into the keyhole bottom right of the rotary switch/option selector and turn it clockwise until the knob/switch is totally covered by the red cover. To unlock, simply turn the key in the opposite direction.
Screw connection 17.5
Tension clamp connection 17.5 17.5
17.5
Connection system The units offers the following connection technologies: Screw connection • 2 x 1.5 mm2 with wire end ferrule • 2 x 2.5 mm2 without wire end ferrule Tension clamp connection • 2 x 1.5 mm2 with wire end ferrule • 2 x 2.5 mm2 without wire end ferrule
D.3
BT-SERIES – Timer
Timer
Installation timer
• Screw or tension clamp connection • LED status indicator Input: Output: • Approvals a 508 EN 61812-1 IEC 60947-5-1 IEC 60664-1 EN 55011
Type designation:
D
B = Building T = Timer R = Response Delay TT = Two Times M = Multifunction, 8 ranges
voltage present output active r 22.2 Nr. 14 IEC 60664-1 EN 61812-1 IEC 60947-5-1 EN 50082-2
Input Rated voltage Voltage tolerance Breaking voltage Power consumption per type
V AC V DC
Reset time Insulation
Contacts hard gold plated 24 ... 230 V AC, 50/60 Hz, 24 ... 48 V DC 85 ... 110 % of rated voltage Max. 2.4 V AC/DC 21...33 VA at 230 V 0.6...1.3 W at 24 V Min. 0.1 s (BTDS: 0.5 s)
Insulation resistance
100 MΩ min., at 500 V DC
Insulation test voltage between input and output, to enclosure between non-adjacent contacts
2000 V AC, 50/60 Hz, 1 min 1000 V AC, 50/60 Hz, 1 min
MF = Multifunction, 4 ranges
Ingress protection class Output
IP30, terminal block IP20
DS = Delta, Star
Contact/contact material Switch output
1 change-over contact (BTDS 2 NOC) / AgNi 90/10 5 A at 250 V AC, resistive load (cos w=1)
S = Screw Z = Tension
Service life
mechanical min. electrical min.
107 switching cycles (no load, 1800/h) 105 switching cycles (5A at 250 V AC, resistive load at 1800/h)
Time range Repetition accuracy Other data
0,10 s…120 h ±1%
Flammability class as per UL 94 Ambient temperature/storage temperature Humidity
V-2 –10...+55 °C / –25...+65 °C (without condensation) 35...85 % rel. humidity, no condensation
Clamping range (nominal/min/max) Length x width x height
mm2 mm
80.0 x 17.5 x 73.0
Accessories Designation Locking and adjusting key
D.4
Type BT Lock Pen
Qty. 1
Order No. 8659840000
BT-SERIES – Timer
Timer
Multifunction relay with control input (BTM)
Ordering data Connection system Screw connection
Type BTM-S
Qty 1
Order No. 8647700000
Tension clamp
BTM-Z
1
8647710000
Functions Function A – on-delay
Connect power supply (A1/A2). When the input signal (B1/A2) is applied, the on-delay lasting for the set time T starts. The output R (15/18) connects the load at the end of the set time. To reset, the power supply has to be switched off.
Function E – passing make function A1 / A2 B1 / A2 15 / 18
Connect power supply (A1/A2). After applying the input signal (B1/A2), output R (15/18) connects the load immediately. At the end of the set delay time T, output R (15/18) switches the load off again.
D
A1 / A2 B1 / A2 15 / 18
Function G – on and off-delay function Function B – pulse emitter (starting at normal position)
Connect power supply (A1/A2). After applying the input signal (B1/A2), output R (15/18) switches the load synchronously and alternately between the normal and operated positions within the set time T. In this function, the cycle starts at the normal position.
A1 / A2 B1 / A2 15 / 18
Connect power supply (A1/A2). Time delay T begins after applying the input signal (B1/A2). At the end of this time, output R (15/18) connects the load (on-delayed). After the input signal (B1/A2) has been switched off again, the output switches the load off again after the set time (off-delayed).
A1 / A2 B1 / A2 15 / 18
Function B2 – pulse emitter (starting at operated position)
Connect power supply (A1/A2). After applying the input signal (B1/A2), output R (15/18) switches the load synchronously and alternately between the normal and operated positions within the set time T. In this function, the cycle starts at the operated position.
Function J – on-delay with pulse A1 / A2 B1 / A2 15 / 18
Connect power supply (A1/A2). Time delay T begins after applying the input signal (B1/A2). At the end of this time, the output R (15/18) connects the load for 1 second.
A1 / A2 B1 / A2 15 / 18
s
approx. 1 s ± 0.6 s (fixed)
Function C – interval time-delay
Connect power supply (A1/A2). After applying the input signal (B1/A2), output R (15/18) connects the load for the set time T. Output R (15/18) switches the load off again at the end of time T. After switching off the input signal (B1/A2), output R (15/18) connects the load again for the set time T. Output R (15/18) switches the load off again at the end of time T.
A1 / A2 B1 / A2 15 / 18
Function D – off-delay function
Connect power supply (A1/A2). After applying the input signal (B1/A2), output R (15/18) connects the load. The time delay T begins after the input signal (B1/A2) has been switched off. At the end of time T, output R (15/18) switches the load off again.
A1 / A2 B1 / A2 15 / 18
D.5
BT-SERIES – Timer
Timer (BTR)
Timer
Multi-function relay without control input (BTMF)
Ordering data
Ordering data
Connection system Screw connection
Type BTMF-S
Qty 1
Order No. 8647680000
Connection system Screw connection
Type BTR-S
Qty 1
Order No. 8647720000
Tension clamp
BTMF-Z
1
8647690000
Tension clamp
BTR-Z
1
8647730000
Functions
Functions
Function A – on-delay
D
When the input signal (A1/A2) is applied, the on-delay lasting for the set time T starts. The output R (15/18) connects the load at the end of the set time. To reset, the power supply has to be switched off.
Function A – on-delay
When the power supply is connected (A1/A2), the on-delay lasting for the set time T starts. The output R (15/18) connects the load at the end of the set time.
A1 / A2 15 / 18
Function B2 – pulse emitter (starting at operated condition)
After applying the input signal (A1/A2), output R (15/18) switches the load synchronously and alternately between the normal and operated positions within the set time T. In this function, the cycle starts at the operated position.
A1 / A2 15 / 18
Function E – passing make function
After applying the input signal (A1/A2), output R (15/18) connects the load immediately. At the end of the set delay time T, output R (15/18) switches the load off again.
A1 / A2 15 / 18
Function J – on-delay with pulse
Time delay T begins after applying the input signal (A1/A2). At the end of this time, the output R (15/18) connects the load for 1 second.
D.6
A1 / A2 15 / 18
s
approx. 1 s ± 0.6 s (fixed)
A1 / A2 15 / 18
BT-SERIES – Timer
Timer (BTDS)
Timer
Timer (BTTT)
Ordering data
Ordering data
Connection system Screw connection
Type BTTT-S
Qty 1
Order No. 8647740000
Connection system Screw connection
Type BTDS-S
Qty 1
Order No. 8647660000
Tension clamp
BTTT-Z
1
8647750000
Tension clamp
BTDS-Z
1
8647670000
Functions
Functions
Function BTTT – pulse emitter
When the power supply is connected (A1/A2), the repeat cycle begins with two independently adjustable times. The standard setting is to start at the normal position. A bridge between connections A1 and A2 allows the module to start at the operated position.
Star-delta changeover A1 / A2 15 / 18 T1
T2
T1
T2
T1
T2
A1 / B1
After connecting the power supply, output R1 (17/18) connects immediately. At the end of time T1, output R1 (17/18) switches off and time T2 starts. At the end of time T2, output R2 (27/28) connects. After switching off the power supply, output R2 (27/28) switches off.
D
A1 / A2 17 / 18 27 / 28 T1
T2
15 / 18 T1
T2
T1
T2
T1
T2
D.7
MCZ-SERIES – Timer
Timer
Miniconditioner MCZ TO
24 V DC 50 ms
24 V DC 150 ms
• Components for lengthening short pulses for the PLC • Fixed switch-off delay • Low input power • Tension-clamp connection system • Plug-in cross-connection • 6 mm width • For mounting on TS 35
3 -
4 +
Output
2
t= 50ms
3 -
4 +
OV
Input
Output
2 OV
Input
t= 150ms
1 + 24V
D
1 + 24V
Technical data Input Rated control voltage Rated current DC Power rating Switch-off delay Min. pulse duration Output Switching voltage DC, max. Max. switching current Max. switching frequency at rated load Rated data Ambient temperature (operational) Storage temperature Humidity Approvals Insulation coordination (EN 50 178) Rated voltage Impulse withstand voltage Overvoltage category Pollution severity Clearance and creepage distances for control/load side Dielectric strength for control side - load side
Dimensions Clamping range (nominal / min. / max.) Length x width x height
mm² mm
Note
24 V DC ±10 % 6.7 mA ±10 % 160 mW 50 ms 2 ms
24 V DC ±10 % 6.7 mA ±10 % 160 mW 150 ms 2.5 ms
48 V 20 mA 20 Hz
48 V 20 mA 5 Hz
-25 °C...+50 °C -40 °C...+85 °C 40°C / 93% rel. humidity, no condensation CSA; cURus; CE
-25 °C...+50 °C -40 °C...+85 °C 40°C / 93% rel. humidity, no condensation CSA; cURus; CE
300 V 6 kV III 2 ≥ 5.5 mm 4 kV
300 V 6 kV III 2 ≥ 5.5 mm 4 kV
Tension clamp connection 1.5 / 0.5 / 2.5 91 / 6 / 63.2
Tension clamp connection 1.5 / 0.5 / 2.5 91 / 6 / 63.2
For mounting on TS 35
For mounting on TS 35
Ordering data Connection system
Type Tension clamp connection
MCZ TO 24VDC/50MS
Qty.
Order No.
Type
10
8324590000
MCZ TO 24VDC/150MS
Note
Accessories AP MCZ end plate
D.8
8389030000
AP MCZ end plate
8389030000
Qty.
Order No.
10
8286410000
DK-SERIES – Timer
Mini-coupler DKZ
24 V DC 50 ms
24 V DC 150 ms
Timer
• Components for lengthening short pulses for the PLC • Fixed switch-on/switch-off delay • Low input power • Screw connection system • 6 mm width • For mounting on TS 35
Output 3
4
3
1 + 24V
+
48V 20mA
Output
Input
t= 50ms
48V = 20mA
2
-
4
OV
Input 1 + 24V
+ t= 150ms
2
-
OV
D
Technical data Input Rated control voltage Rated current AC Rated current DC Power rating Switch-off delay Min. pulse duration Output Switching voltage DC, max. Max. switching current Max. switching frequency at rated load Rated data Ambient temperature (operational) Storage temperature Humidity Approvals Insulation coordination (EN 50 178) Rated voltage Impulse withstand voltage Overvoltage category Pollution severity Clearance and creepage distances for control/load side Dielectric strength for control side - load side
Dimensions Clamping range (nominal / min. / max.) Length x width x height
mm² mm
Note
24 V DC ±18 %
24 V DC ±18 %
6.7 mA 160 mW 50 ms 2 ms
6.7 mA 160 mW 150 ms 2.5 ms
48 V 20 mA 20 Hz
48 V 20 mA 20 Hz
-25 °C...+50 °C -40 °C...+85 °C 40°C / 93% rel. humidity, no condensation CE
-25 °C...+50 °C -40 °C...+85 °C 40°C / 93% rel. humidity, no condensation CE
300 V 4 kV III 2 ≥ 4 mm 4 kV
300 V 4 kV III 2 ≥ 4 mm 4 kV
Screw connection 4 / 0.5 / 4 65 / 6 / 62
Screw connection 4 / 0.5 / 4 65 / 6 / 62
For mounting on TS 35 rail
For mounting on TS 35 rail
Ordering data Connection system
Type Screw connection
DKZA 35 24VDC 50MS
Qty.
Order No.
Type
10
8008180000
DKZA 35 24VDC 150MS
Qty.
Order No.
10
8022110000
Note
Accessories End plate AP DK4 0687560000
End plate AP DK4 0687560000
D.9
DK-SERIES – Timer
Timer
Mini-coupler DKZ
24 V UC 1 s
24 V DC 10-100 ms
• Components for lengthening short pulses for the PLC • Fixed switch-on/switch-off delay • Low input power • Screw connection system • 6 mm width • For mounting on TS 35
Output 3
Input
+
48V 20mA
3
1 — 24V ~
tv=10...100s 5...48V 4 + 100mA
t=1s
Vcc
Vcc
+ 24V
+24V
OUT tv
4
D
2 OV
-
5
2 OV
IN t
1
t
–
Technical data Input Rated control voltage Rated current DC Rated current AC Switch-on delay Switch-off delay Power rating Output Switching voltage DC, max. Max. switching current Rated data Ambient temperature (operational) Storage temperature Humidity Approvals Insulation coordination (EN 50 178) Rated voltage Impulse withstand voltage Overvoltage category Pollution severity Clearance and creepage distances for control/load side Dielectric strength for control side - load side
Dimensions Clamping range (nominal / min. / max.) Length x width x height
mm² mm
Note
24 V UC ±10 % 5.1 mA 6.1 mA 1s max. 0.7 ms 130 mW / 150 mVA
24 V DC ±20 % Approx. 12 mA
48 V 20 mA
48 V 100 mA
-25 °C...+50 °C -40 °C...+85 °C 40°C / 93% rel. humidity, no condensation CE
-25 °C...+50 °C -40 °C...+85 °C 40°C / 93% rel. humidity, no condensation CE
300 V 4 kV III 2 ≥ 4 mm 4 kV
300 V 6 kV IV 2 ≥ 5.5 mm 4 kV
Screw connection 4 / 0.5 / 4 65 / 6 / 62
Screw connection 4 / 0.5 / 4 77 / 6 / 62
For mounting on TS 35 rail
For mounting on TS 32/35 rails
10...100 ms (adjustable) 290 mW
Ordering data Connection system
Type Screw connection
DKZ 35 24VUC 1S
Qty.
Order No.
Type
10
8008190000
DKZ DK5 24VDC 10-100MS
Note
Accessories End plate AP DK4 0687560000
D.10
End plate AP DK5 8268870000
Qty.
Order No.
10
8228680000
DK-SERIES – Timer
24 V DC 1-100 s
24 V DC 10-100 ms
Timer
24 V DC 0.1-1 s
5...48V 4 100mA
OUT tv
Vcc 3 + tv=1...100s
Vcc 1 +24V 2
Vcc + 24V tv=100ms...1s 3
t
5...48V 100mA
2 OV
IN
4
+
Vcc + 24V
1
3
5
5–
Vcc +24V
tv=10...100ms IN
OUT t
t
2 OV
5...48V 4 + 100mA
tv
t
Vcc
OUT tv
5
–
2 OV
IN t
1
t
D
–
24 V DC ±20 % Approx. 12 mA
24 V DC ±20 % Approx. 12 mA
24 V DC ±20 % Approx. 11 mA
100 ms ... 1 s (adjustable)
1 ... 100 s (adjustable)
290 mW
290 mW
48 V 100 mA
48 V 100 mA
48 V 100 mA
-25 °C...+50 °C -40 °C...+85 °C 40°C / 93% rel. humidity, no condensation CE
-25 °C...+50 °C -40 °C...+85 °C 40°C / 93% rel. humidity, no condensation CE
-25 °C...+50 °C -40 °C...+85 °C 40°C / 93% rel. humidity, no condensation CE
300 V 6 kV IV 2 ≥ 5.5 mm 4 kV
300 V 6 kV IV 2 ≥ 5.5 mm 4 kV
300 V 6 kV IV 2 ≥ 5.5 mm 4 kV
Screw connection 4 / 0.5 / 4 77 / 6 / 62
Screw connection 4 / 0.5 / 4 77 / 6 / 62
Screw connection 4 / 0.5 / 4 77 / 6 / 62
For mounting on TS 32/35 rails
For mounting on TS 32/35 rails
For mounting on TS 32/35 rails
10 ... 100 ms (adjustable)
Type DKZ DK5 24VDC 0.1-1S
End plate AP DK5 8268870000
Qty.
Order No.
Type
10
8243780000
DKZ DK5 24VDC 1-100S
End plate AP DK5 8268870000
Qty.
Order No.
Type
10
8019650000
DKZA DK5 24VDC 10-100MS
Qty.
Order No.
10
8228690000
End plate AP DK5 8268870000
D.11
DK-SERIES – Timer
Timer
Mini-coupler DKZ
24 V DC 0.1-1 s
24 V DC 1-100 s
• Components for lengthening short pulses for the PLC • Fixed switch-on/switch-off delay • Low input power • Screw connection system • 6 mm width • For mounting on TS 35
3
Input
Vcc +24V
+24V
1
3
tv=100ms...1s 5...48V 100mA
4
+24V
tv=1...100s OUT
2 OV
IN
5...48V 100mA
t
5–
D
Input
Vcc +24V
4
OUT
1
2 OV
IN t
5–
Technical data Input Rated control voltage Rated current DC Rated current AC Switch-off delay Power rating Output Switching voltage DC, max. Max. switching current Rated data Ambient temperature (operational) Storage temperature Humidity Approvals Insulation coordination (EN 50 178) Rated voltage Impulse withstand voltage Overvoltage category Pollution severity Clearance and creepage distances for control/load side Dielectric strength for control side - load side
Dimensions Clamping range (nominal / min. / max.) Length x width x height
mm² mm
Note
24 V DC ±20 % Approx. 11 mA
24 V DC ±20 % Approx. 11 mA
100 ms ... 1 s (adjustable) 260 mW
1 ... 100 s (adjustable)
48 V 100 mA
48 V 100 mA
-25 °C...+50 °C -40 °C...+85 °C 40°C / 93% rel. humidity, no condensation CE
-25 °C...+50 °C -40 °C...+85 °C 40°C / 93% rel. humidity, no condensation CE
300 V 6 kV IV 2 ≥ 5.5 mm 4 kV
300 V 6 kV IV 2 ≥ 5.5 mm 4 kV
Screw connection 4 / 0.5 / 4 77 / 6 / 62
Screw connection 4 / 0.5 / 4 77 / 6 / 62
For mounting on TS 32/35 rails
For mounting on TS 32/35 rails
Ordering data Connection system
Type Screw connection
DKZA DK5 24VDC 0,1-1S
Qty.
Order No.
Type
10
8243770000
DKZA DK5 24VDC 1-100S
Note
Accessories End plate AP DK5 8268870000
D.12
End plate AP DK5 8268870000
Qty.
Order No.
10
8019630000