welcom WMS Underfloor Heating is one of the UK’s leading suppliers and installers of underfloor heating and cooling systems for new build and refurbishment projects. Our capability is second to none - we offer complete engineering solutions at every stage, from innovative project design, complete system installation, commissioning and testing to maintenance contracts. We assist architects, consultants, local authorities and developers to achieve their aims by delivering the best heating and cooling solutions for their clients through an unbeatable combination of experience, reliability and service. In this brochure you will discover who we are, how we work and the great service that we offer. We hope you enjoy reading on and look forward to working with you on your next project.
2 | WMS Underfloor Heating
e
CONTENTS 4 6 8 10 12 14 16 28 48 74 75
Our Mission About Us Underfloor Heating Overview The Complete Solution How Underfloor Heating and Cooling Works Project Pathway Components Systems Case Studies Support Centres Accreditations and Quality Standards
WMS
Underfloor Heating
WMS Underfloor Heating | 3
OUR MISSION
our 4 | WMS Underfloor Heating
mission OUR MISSION
WMS is an evolving and innovative organisation that is committed to meeting our customers’ needs for underfloor heating and cooling by developing a culture of continuous improvement. We deliver high-quality, cost-effective underfloor heating systems on budget and on schedule by employing and supporting motivated, flexible and focused teams. We value the importance of our relationships and will continue to remain fair and true in our dealings with customers, employees and partners. Our customers count on our dependability, our drive and our integrity. We take great pride in these accomplishments and build on them every day.
WMS Underfloor Heating | 5
about us At WMS Underfloor Heating, excellence comes as standard. We don’t just give you an efficient underfloor heating system that works but we work with you to build a system that suits your needs with expert project engineering that keeps your project on time and within budget. Our long trading history and expertise has allowed us to become one of the UK’s major suppliers and installers of underfloor heating systems in the UK. We offer complete engineering solutions at every stage from innovative project design, complete system installation, commissioning and testing to our own ‘site assist’ maintenance contracts. We only deliver the very best heating and cooling solutions to our clients. We welcome you to visit us at our head office in Hertfordshire where you can experience underfloor heating in action throughout our offices and meet our technical advisors. They will demonstrate all our systems including our sophisticated controllers, thermostats, manifold systems and of course our high performance, five layered PE-RT pipe. With our experience, knowledge and research we can help you achieve your goals, meet your deadlines and fulfil your commitments.
6 | WMS Underfloor Heating
s
ABOUT US
We understand what it takes to make your project a success.
WMS Underfloor Heating | 7
o
Underfloor Heating Overview
Energy reaches into every corner of the room with underfloor heating. There are no cold spots, no hot heads and no cold feet ! With underfloor heating the air temperature is hottest at floor level, where it is needed and reduces as it rises to the ceiling. Conventional radiator systems have the opposite effect where air temperature is coolest at floor level and hottest at ceiling level resulting in high heat loss through the ceiling which means higher energy usage and fuel bills. Underfloor heating can also achieve comfort levels of heating with air temperatures that are around 2째C lower than other systems.
8 | WMS Underfloor Heating
These factors mean that when designing an underfloor heating system, less allowance is required for building height which means lower energy requirements for buildings with high ceilings such as warehouses, theatres, churches, schools, barn conversions and leisure centres.
overview OVERVIEW
Complete flexibility With multiple control options, your comfort is achievable at the press of a button. Underfloor heating is invisible and being under the surface gives you a totally flexible layout with no radiators to limit interior designs and furniture arrangements. Underfloor heating can also add value to property through its silent operation and lower running costs.
Energy efficient Underfloor heating is the most energy efficient way of transferring heat into any room since it works almost entirely by radiation, from the floor surface onto other surfaces in the room and from there heating the airspace. This is a more natural form of heating and requires lower flow temperatures due to its increased surface area.
Eco-friendly Underfloor heating is an integral part of the green revolution in contemporary heating and cooling solutions. It requires much lower water temperatures than conventional heating systems, it can be connected to a range of eco-friendly heat generators like solar panels and geo-thermal heat pumps making it the natural partner for many heating and cooling solutions in the renewables sector.
Healthier environment Radiant energy is emitted by the floor making it the warmest part of the room with the air cooling as it rises, with the coolest air at the ceiling and the warmest air at the floor level, where we want it to be. This radiation method creates fewer draughts and dust movements and explains why underfloor heating is considered to be the most comfortable and healthiest form of heating. For those who have it, few ever want to return to conventional systems.
WMS Underfloor Heating | 9
The Complete Solution
Underfloor heating systems provide ideal comfort levels for the home, office, retail environment, leisure or industrial complex. They are highly efficient, proven, durable and environmentally friendly.
Manifold The Ambiente stainless steel manifold is a piece of engineering excellence. Acting as the heart of the system, this sophisticated piece of equipment distributes warm water throughout the underfloor heating system. > more information on page 22
Underfloor heating also requires less energy than conventional heating systems, they are completely silent in operation, emit zero emissions and do not rely on blowers or hot surfaces to distribute heat throughout your building. During the summer months our systems can be switched to provide underfloor cooling by simply running cool water through the system. This absorbs heat from the surrounding air and creates a pleasantly cool environment. Our aim is simple. We want to enrich your way of life by offering you a heating system that is more comfortable, reliable, cleaner and much more efficient for the future.
Driveway Heating and Snow Melting Systems Fully automated, radiant heat snow melting systems can be installed in small customised driveways, large commercial parking structures, ramps, loading bays, walkways and more.
10 | WMS Underfloor Heating
OVERVIEW Wi-fi Control Control your system via wi-fi from the office or, if you are unexpectedly delayed you can adjust your heating and cooling settings remotely.
AmbiClip System This is one of our most popular underfloor heating systems providing a quick, flexible and effective form of heating within a screeded floor buildup. > More information on page 32
Thermostat Our wide range of controls caters for any application. Every room benefits from individual time and room temperature control. > more information on page 26
AmbiTak System Underfloor heating pipe is fixed directly to onto gridded insulation board. It is quick to install, economical and very effective in terms of thermal output. > More information on page 32
AmbiPlate 20 System This makes a perfect underfloor system for joisted and battened upper floors. > More information on page 36
WMS Underfloor Heating | 11
How Underfloor Heating and Cooling Works Underfloor heating works by circulating warm water through a series of continuous loops that are fitted underneath your floor creating a large radiant surface that heats your room from the floor upwards. This radiant form of heating is much more comfortable than the convected heat provided by radiators which draws cold air across the floor, heating it and then convecting it upwards towards the ceiling. Underfloor cooling works in very much the same way as underfloor heating except the energy transfer is reversed. Where underfloor heating radiates thermal energy from the floor surface into the air space, underfloor cooling relies on warm air passing over the cooler floor surface which absorbs radiant energy from the air and reduces the air temperature in the room. This process of passing chilled water through the floor keeps the floor area cool which continually absorbs warm air from the room.
Comparing underfloor heating with radiators
Conventional Radiators 12 | WMS Underfloor Heating
Underfloor Heating
HEATING & COOLING
Comparing underfloor cooling with conventional air conditioning
Conventional Air Conditioning
Underfloor Cooling WMS Underfloor Heating | 13
Project Pathway A step-by-step guide on how your project will progress from your initial enquiry to the successful completion.
> Enquiry
> Pre-Contract
> Projects Team
> Design
> Installation
Our sales team will help you select the best heating and cooling solution for your project, defining the requirements, guiding you through the process, reviewing all the options until we arrive at the best solution for your project.
We submit detailed proposals containing our design proposals, control options, warranty details and pricing information. We also add our unique Project Engineering Standard (PES) where appropriate, to ensure that we always provide you with our most cost effective solutions.
Following confirmation of an order, we appoint a project manager who will undertake an on-site survey to assess conditions ‘on the ground’. The project manager will complete a components list ready for despatch to site. Risk assessment and method statements are also produced at this stage.
Our design team uses a unique, ‘design approved’ system that includes heat loss calculations and A1 detailed CAD layout pipe drawings.
Our team of highly skilled and experienced installers will install the system according to your specifications. Adhering to our own ‘Quality Marque’ installation procedure, you can be sure that we will complete our install in the most competent and professional manner.
Define requirements Research options Control strategy analysis Specification 14 | WMS Underfloor Heating
Detailed estimating proposals Make recommendation Sample approval
Project manager assigned On-site survey Co-ordination of associated trades Agree delivery dates Project planning Timescales approved
Heat loss calculations Output calculations Pipe layout drawing Manifold positions finalised
Delivery System installation Pressure tests Sign-off
PROJECT PATHWAY
> Commissioning
> Technical Support
> Handover
> Guarantee
> ‘Site Assist’
Following installation and before handover to the client we carry out a series of comprehensive tests in accordance with our own procedures to ensure the system is in perfect working order.
Our technical team offers full UFH technical support with all wiring and plumbing queries.
At handover you can be sure that our system is in 100% working order. We will provide all necessary instructions on the use of the system and manuals and data sheets. We also leave you with full details of component and system guarantees.
As an ISO 9001 registered company, we go to extraordinary lengths to make sure you are completely satisfied with your system and that it will continue to function for many years to come.
Our ‘Site Assist’ range of maintenance contracts are designed to provide complete peace of mind to end users or developers as they hand over buildings to clients. ‘Site Assist’ contracts have parts and labour options and include our planned maintenance servicing schedule.
We also provide ‘as installed’ drawings and a comprehensive O&M manual that contains all the information required to set up, run and perform routine tests on your system.
All our UFH pipe work carries a 50 year warranty. We also offer extended guarantees for our control systems, manifolds and thermostats to give you complete peace of mind.
st ssi
50 System set-up Hand over to client Commissioning report
Comprehensive support Full documentation
100% working order Guarantees O&M manuals
50 year standard guarantee Extended guarantees available
site a
TM
Planned maintenance Complete peace of mind WMS Underfloor Heating | 15
CASE STUDIES
compone 16 | WMS Underfloor Heating
CASE STUDIES
ents
18 20 22 24 26
Main Components Overview Design Capability Manifold PE-RT Pipe Control Systems
WMS Underfloor Heating | 17
What are the Main Components of an Underfloor Heating System? WMS Underfloor Heating can design, supply and install the complete system for you. Our manifolds are designed for connection to any heat source from a conventional boiler to ground source heat pumps or solar panels.
1
> Heat Source
The heat source can be any type of water heater, from a conventional boiler powered by gas or electricity or any of the renewable energy sources, including ground source heat pumps and solar panels. Since underfloor heating heats the whole floor area, the water temperatures required are much lower than that of radiators.
Supplied by others 18 | WMS Underfloor Heating
2 > Design
The underfloor heating design is unmistakably the most important part of any underfloor heating system. Our dedicated design team produces accurate and comprehensive drawings for every system that we install, maximising performance for all our systems, guaranteeing that we will supply the most cost effective and efficient solution for your project.
Supplied by WMS
3
> Manifold
The manifold distributes water from the heating source to the relevant zone. Manifolds will typically have a mixer valve to allow them to mix hot flow water with the cooler return to achieve the reduced temperatures required by underfloor heating.
COMPONENTS
4 > Pipe
> Systems
5
6
The pipe is at the heart of every underfloor heating system and at WMS we make sure that we only use the very best. Our pipe is a five layered polyethylene tube that uses the latest PE-RT technology.
There are many variations of system type, consisting of pipe work that is set within the floor, typically either a screed or timber floor but fixing methods change according to requirements. Our pipes can heat floor areas at low water temperatures and are designed to be effective with almost any floor finish including ceramic tiles, linoleum, wood and carpets.
Effective controls are an essential part of any heating system especially since around 90% of your underfloor heating system is actually underfloor. The control system provides a user interface with your heating system and can be as simple or as complex as your requirements. Underfloor heating temperatures are measured by room thermostats that are situated throughout the building with floor probe options available for sensitive floors.
It is manufactured in Europe to our own specification and contains an integral EVOH oxygen barrier layer which prevents oxygenation of water inside the system. This is a very important feature because air in the system can cause air locks or corrosion.
> Controls
WMS Underfloor Heating | 19
Design Capability Our dedicated CAD design team produces accurate and comprehensive drawings for every system that we install, maximising performance for all our systems and guaranteeing that we will supply the most cost effective and efficient solution for your project.
Having our own design team means that we can be much more flexible during the design stage and can quickly accommodate any alterations to the layout and other requirements as they are specified by the architect, builder or client. We can prioritise these changes in our system and minimise any delays. These drawings are also supplied to our clients for their own records. We also keep all our drawings in our electronic database for future reference and if clients require this information we can readily supply it.
20 | WMS Underfloor Heating
We also supply comprehensive wiring diagrams showing how the system should be wired, by your on-site electrician. Each diagram provides clear, concise and comprehensive electrical layout details for the system. Our design team benefits from our unique, approved design system that includes heat loss and output calculations. We provide detailed CAD drawing layouts showing exact positioning of all UFH pipework, controllers, manifolds and bathroom/kitchen layouts to thoroughly assist the install process and ensure all requirements are met.
DESIGN
“At WMS, Excellence comes as standard”
WMS Underfloor Heating | 21
Manifold: Confidence at the Heart of the System Manifolds are the heart of any underfloor heating system as they control the flow and distribution of water from the heat source (boiler, heat pump etc.) to the individual underfloor pipe circuits. Manifold mixing valves can also be attached to the manifold to regulate the water flow temperature. A pressure gauge ensures that the system is properly pressurised.
22 | WMS Underfloor Heating
MANIFOLDS WMS Underfloor Heating manifolds are manufactured in Europe and represent another quality addition to our range of components. Made out of stainless steel and tested to rigorous standards, they are available in various sizes from just two ports for a small system, up to 12 port versions for areas up to 200M2 . In order to ensure total durability and reliability, our systems are tested to 4 bar for operation within systems that typically operate on less than 3 bar pressure. Following installation, our commissioning engineers provide a comprehensive balancing and commissioning service to ensure the system is working perfectly before handover. At handover we also provide a full list of documentation including a set of ‘as installed’ drawings, detailing exactly where our pipes have been laid and how they are configured in your system. We also provide a comprehensive operating and maintenance (O&M) handbook which gives details of all manufacturing and installation warranties. See the ‘site assist’ section in this brochure for details of our unique aftercare and planned maintenance service contracts that are available for our systems.
WMS Underfloor Heating | 23
PE-RT Pipe: The Hidden Quality WMS Underfloor Heating pipe is a five layered polyethylene tube using PE-RT technology that is manufactured to our own specification and composed of five bonded layers. It contains an integral EVOH oxygen barrier layer to prevent oxygenation of water inside the system. PE-RT pipe PE-RT stands for ‘polyethylene at raised temperature resistance’. Polyethylene has excellent properties at high pressures and temperatures as well as being very flexible and easy to use. It is non-corrosive and has very good resistance to frost. It is also creep-resistant and has a high impact strength, which means that if the pipe is distorted it will return to its original shape within a short period of time. The outer layer protects the oxygen barrier from mechanical damage, moisture and other damaging materials. Polymer adhesive A functionalised polythene that acts as an adhesive layer between the polyethylene and the oxygen barrier. EVOH oxygen barrier Made of ethanol vinyl alcohol that prevents oxygen diffusion at up to 80°C.
24 | WMS Underfloor Heating
Oxygen diffusion is a very important factor within underfloor heating. The nature of under floor heating to cover the whole floor area with pipe at relevant spacings creates a huge surface area of plastic, making it vulnerable to its surroundings. It is then essential that the pipe has a very low level of oxygen permeability so that oxygen cannot permeate into the pipe work and cause unnecessary damage and costs. A standard plastic pipe would not meet this level of oxygen permeability. The pipe is installed with no joints within the floor and even when a pipe does need to be joined after the installation, a simple procedure of exposing and reconnecting the two ends is all that is required. Ambiente® pipe is supplied with a 50 year product guarantee. However, assuming the pipe is not disturbed, it is expected to out live the life of the building itself in the vast majority of cases.
PIPE
External PE-RT layer Polymer adhesive EVOH oxygen barrier Polymer adhesive Internal PE-RT layer
AMBIENTE
WARRANTY
50 YEAR
WMS Underfloor Heating | 25
Control Systems Controls are an essential part of any heating system as they create your environment in the most efficient and cost effective way possible. This means ensuring that your system only operates when required and for the minimum period of time. There are various methods of doing this but all are managed by your control system with various levels of integration between the heating zone, heat source and outside temperature. The control system must be accurate and sophisticated as well as easy to use! Room temperature control for underfloor heating is measured by ambient room temperature controllers that are located in each zone. These are linked to the local manifold wiring centre where commands are sent to various relays and other outputs that require a signal.
1 2 3 4 5
Individual temperature control
Simple and easy to use
Individual room temperature control with night setback facility
Simple and has eco setting
Individual programmable room temperature control
User friendly and has a variety of programmes
Individual programmable and networkable room temperature control
Can be networked off a timer to incorporate up to 31 thermostat zones from a central touchscreen controller. Additional features can be included at this level including internet control, holiday mode, hot water control and heating profiles.
Individual programmable room temperature control with BMS integration
From any point in the building and online. Using BMS compatible control system you can use it to control your central heating system, integrate the boiler and control other performance monitoring equipment.
26 | WMS Underfloor Heating
CONTROLLERS
Designed to work with our low voltage thermostats, the Ambiente速 touchpad provides central control of your heating system. It features a colour touch screen capable of controlling of up to 32 thermostats. Each thermostat can be individually named allowing you to easily identify and adjust each zone on the network.
New Picture required
A new feature is the ability to program profiles. Profiles are a stored set of comfort levels that can be applied to a group or rooms as and when required. Remotely program the comfort level of all the networked thermostats from one central point and copy program settings from one thermostat to another across the network. Our controllers can be either hard wired or wireless and sometimes interfaced with your Building Management System giving you full remote control including internet access.
WMS Underfloor Heating | 27
systems 28 | WMS Underfloor Heating
30 32 34 36 38 40 42 44 46
Systems Index Screeded Floor Systems Floating Floor Systems Suspended Floor Systems Structural Floor System Raised Access System Low Profile Systems Bespoke Systems Maintenance Contracts ‘Site Assist’
WMS Underfloor Heating | 29
: Screeded
Floating
Suspended
Structural
Screeded floor system is incorporates underfloor heating system within a screeded floor construction.
The floating floor range is developed around grooved and foiled insulation systems. They can be easily adapted for installation with joisted and battened floors.
The AmbiPlate systems are designed to suit battened floor buildups. This system can be easily adapted to suit sprung sports floors, acoustic batten floors and over-battened floors.
Designed to suit high load bearing floor constructions, the AmbiStructural system is perfectly suited for use in car showrooms, factories, aircraft hangers and other applications where high point loadings are required.
This is our most popular underfloor heating system that provides a rapidly installed, flexible and very effective system of heating and cooling.
structural
suspended
floating
screeded 30 | WMS Underfloor Heating
Raised Access
Low Profile
Bespoke Systems
The AmbiAF system is bespoke designed to incorporate underfloor heating into a raised access floor. As well as providing a primary heating or cooling source it also maintains full access to services within the floor void.
Low profile systems are uniquely developed to offer a series of low floor buildup solutions for use in areas where there is not enough height/ thickness to accommodate a standard floor construction.
Due to a combination of experience, knowledge and innovation, WMS is capable of developing bespoke systems to suite your needs. Please contact our technical support team to find out how we can help.
SYSTEMS
bespoke
low profile
access
WMS Underfloor Heating | 31
: Screeded Floor Systems Screeded floor systems are our most popular underfloor heating systems. They provide a quick, flexible and effective form of heating within a screeded floor build-up. With the majority of solid floor build-ups requiring an insulated screed to meet building regulations, this system can easily be accommodated into most floor applications without affecting the overall buildup.
Floor screed Expansion edging and wall insulation 17mm Ambiente UFH pipe Cliprail Rigid insulation board (25mm minimum) Acoustic detail (if required) Damp proof membrane (if required) Concrete sub-floor
Systems
AmbiClip (above)
AmbiTak
AmbiCastellated
Cliprail system Data sheet: 10004-3
Tacker system Data sheet: 10004-16
Castellated system Data sheet: 10004-33
32 | WMS Underfloor Heating
SYSTEMS
> Maximum output > Quick installation > Suit irregularly shaped rooms > Versatile pipe layout plan Edge and floor insulation is installed over the subfloor on to which cliprails are then fixed to by both the adhesive backing strip and barbed staples (where WMS is not supplying the insulation, checks should be made to ensure that the insulation is compatible with the cliprail system). Once the cliprails are secured in position, the underfloor heating pipework is laid in continuous loops and clipped down in accordance with the underfloor heating design drawings. Once complete, the system is pressure tested and witnessed to finalise the installation. We recommend that the screeding process is scheduled to follow shortly after installation to avoid leaving the system vulnerable to damage. WMS should be notified if a liquid screed is being used, as the insulation must be sealed to provide a watertight base. Where controls are required from WMS, these will be supplied as ‘second fix’ items for others to fit.
screeded
> Low cost installation
WMS Underfloor Heating | 33
: Floating Floor Systems Our original floating floor system has been developed over the years to provide a range of applications where similar panel types are incorporated into different build ups and configurations to provide a bespoke solution. The foiled and grooved insulation panels are unique to WMS and are available in numerous different material types.
Timber flooring Grooved and foiled insulation board 17mm Ambiente UFH pipe Damp proof membrane (if required) Concrete sub-floor
Systems
AmbiFloat 10 (above)
AmbiFloat 20
AmbiFloat 30 A
Floating floor on concrete Data sheet: 10004-5
Floating floor between battens on timber Data sheet: 10004-34
Fl Floating floor between joists Data sheet: 10004-36 D
34 | WMS Underfloor Heating
SYSTEMS
> Panels manufactured to suit layout plan > Rapid installation > Wide range of applications
AmbiFloat 10 system requires a flat and level sub floor for the insulation to fully support the floor finish on top. The insulation is pre-grooved to take the underfloor heating pipework and over laid with foil to assist the distribution of heat. The polystyrene insulation panels are manufactured per project to suit the underfloor heating design drawings. The system is then overlaid with a fully floating floor deck onto which your floor finish is applied. In the case of wooden floors, this can be laid directly on to the insulation to minimise height buildup and maximise the heating output. AmbiFloat 20 system has a wide range of applications from sprung sports floors, acoustic floors through to overbattened floors. AmbiFloat 30 system is designed to fit between timber joists supported by battens. This provides a neat solution incorporating the aluminium profile and insulation into one product. The timber subfloor should be installed in the normal way over the joists/battens onto to which your finishes are applied. Engineered timber floors can be fixed directly to the joists/battens.
floating
> Can be used in existing floor constructions
‚ WMS installed the AmbiFloat system with battens installed at Golders Green Parish Church as part of a refurbishment project. WMS Underfloor Heating | 35
: Suspended Floor Systems Suspended floor system is designed to suit battened floor buildups but can be easily adapted to suit sprung sports floors, acoustic battened floors and overbattened floors.
Timber flooring 17mm Ambiente UFH pipe Aluminium diffuser plate (390mm x 1200mm) Damp proof membrane (if required) Concrete sub-floor
Systems
AmbiPlate 20 (above)
AmbiPlate 30
Battened floors Data sheet: 10004-4
Joisted floors Data sheet: 10004-11
36 | WMS Underfloor Heating
SYSTEMS
> Maximum heat transfer > Even heat diffusion – highly conductive > No impact on floor buildup > Quick response time The systems consists of aluminium diffuser plates being fixed directly on to the battens/ joists. The plates contain grooved channels into which the underfloor heating pipework is installed in continuous lengths and piped back to the underfloor heating manifold. Before the underfloor heating system is installed, insulation should be laid between the battens/joists and should be laid as close as possible to the underside of the pipework to maximise heating output. The system is then pressure tested upon completion to 4 bar, witnessed by a site agent and signed off. The system should be left under pressure whilst the timber flooring is being laid to highlight any potential damage to the pipework during this process. Controls and pumps (if required) are supplied as loose items for others to install. An ‘as Installed’ drawing will be issued after the installation for the client’s records.
‹ WMS supplied and installed the AmbiPlate 30 system on the upper floors of this new build luxury housing development in north London with AmbiClip system (see page 32) on ground floors.
suspended
> Designed for joisted/battened floors
WMS Underfloor Heating | 37
: Structural Floor System Designed to suit high load bearing floor constructions, the AmbiStructural system is perfectly suited for use in car showrooms, factories and aircraft hangers and many other high point load areas.
Floor screed/concrete Expansion edging and wall insulation Reinforcing mesh 17mm Ambiente UFH pipe Pipe clips High density insulation board Damp proof membrane (if required) Concrete sub-floor
System
AmbiStructural (above) Structural floor system Data sheet: 10004-18
38 | WMS Underfloor Heating
SYSTEMS
> UFH pipe is clipped to reinforcing mesh > Heating is applied evenly across large floor areas > Versatile pipe layout
The AmbiStructural system can be used in a wide variety of applications where a load bearing structural floor is required. Such systems can be commonly found in car show rooms and airport hangers where point loadings can be extremely high. High density flooring insulation panels of the required specification are laid over the complete floor area which is overlaid with an A142 reinforcing mesh on to which the underfloor heating pipework is clipped. The specialist 17mm underfloor heating pipework is secured to the mesh in accordance with the underfloor heating designs with no joins in the pipework under the floor. Each loop circuits back to the underfloor heating manifold, complete with flow regulating valves, ball valves, pumps, mixing valves, drain/fill points, auto air vent and pressure gauge. The system must be filled and pressure tested upon completion and left under pressure whilst the concrete is laid. If controls are required from WMS, these will be supplied as ‘second fix’ items for others to fit.
structural
> Low cost and fast installation
‹ Top: AmbiStructural installed at aircraft hanger facility where the floor and heating system has to withstand loads of up to 250 tonnes. ‹ Bottom: AmbiStructural installation at a newly built car showroom. WMS Underfloor Heating | 39
: Raised Access Floor System The AmbiAF system is uniquely designed to incorporate underfloor heating into raised access floor constructions. The system provides a primary heating or cooling source whilst maintaining full access to services within the floor void.
600mm flooring panel
Foiled and grooved insulation panel 17mm Ambiente UFH pipe Pedestal bracket Access flooring pedestal Concrete sub-floor
System
AmbiAF Raised access floor system Data sheet: 10004-31
40 | WMS Underfloor Heating
SYSTEMS
> Provides primary source of heating and/or cooling > Low profile modules allow easy access to floor void underneath > Modules can be easily dismounted and repositioned when office layout changes The AmbiAF system is uniquely designed to incorporate underfloor heating into a raised access floor construction. A U-shaped bracket is mounted on to the pedestals on to which insulation profiles are installed. The 35mm x 100mm insulation panels are made of high density insulation and foiled to optimise the energy transfer. This contains a grooved channel into which the underfloor heating pipework is installed with no joints within the floor and piped back to the underfloor heating manifold as detailed on the right. The concept is simple but does require liaison with the access flooring specialist during the design and installation. This system lends itself towards most of the common raised access flooring manufacturers and whilst providing a heating or cooling source, will still maintain full access to services within the floor void.
access
> Injection moulded brackets plug directly into pedestals for rapid installation
The system can take flow temperatures up to 60OC producing outputs between 50-60 w/m2. It can also be disassembled and relaid at a later date if required.
‹ AmbiAF raised access flooring system together with AmbiClip system (see page 32) installed at ‘3 City Place’ office complex near Gatwick. WMS Underfloor Heating | 41
: Low Profile Systems Our low profile system is uniquely designed to offer a slim line alternative to our AmbiFloat systems. At only 18mm total floor build-up this is a popular option for both new build and refurbishment applications.
Screedboard or timber flooring 12mm Ambiente UFH pipe 18mm grooved and foiled insulation Acoustic detail (if required) Timber subfloor Insulation Joist
Systems
AmbiLowboard (above)
AmbiScreedboard A
AmbiChipboard A
Grooved insulation system Data sheet: 10004-39
Grooved screedboard system G Data sheet: 10004-40 D
Grooved chipboard system G Data sheet: 10004-41 D
42 | WMS Underfloor Heating
SYSTEMS
> Suitable for both new and refurbishment applications > Wooden floors can be laid directly over insulation layer > Fits over existing floors
As part of our philosophy of continuous improvement we have developed a range of systems to suit low floor buildups where traditional systems cannot be used. This range is most often used in refurbishment projects where door and ceiling heights are fixed. AmbiLowboard Can be used in existing and new build applications. It utilises the same concept as our AmbiFloat systems but has been scaled down using higher density materials to have minimal impact on the floor buildup. AmbiScreedboard Consists of pre-routered screed boards which offers the perfect solution for tiled floors. The screed boards’ excellent conductivity properties make a highly effective and responsive heating system. Tiles can be laid directly on top of the screed board raising the overall floor buildup by only 18mm. AmbiChipboard Another development of the low floor buildup range that provides a structural floor solution over suspended timber floors, ideally for engineered joists that cant be notched or where full height steels restrict the use of the AmbiPlate system.
low profile
> Ultra slim floor build up
WMS Underfloor Heating | 43
: Bespoke Systems Through a combined wealth of knowledge, experience and innovation - WMS continues to develop new systems for bespoke floor buildups. Please contact our technical support team to enquire as to your specific floor construction.
‚ WMS engineered a bespoke system for the Cutty Sark situated in Greenwich. The £50 million refurbishment project incorporated underfloor heating into the unusual floor construction within the dry berth area.
44 | WMS Underfloor Heating
SYSTEMS BESPOKE
> Experience > Knowledge > Commitment > Opportunity > Excellence
bespoke
> Innovation
WMS Underfloor Heating | 45
Aftercare and Maintenance WMS Site AssistTM is our own service management system that can provide you with complete peace of mind and confidence that your ‘maintained system’ will continue to function efficiently into the future. All WMS engineers are fully trained and capable of carrying out regular servicing to the very highest standards on a proactive and regular basis with a range of contract levels to suit your requirements. Programmed health checks will maximise the life of the components in your system, will help to reduce energy bills and reduce the system’s carbon footprint. Our services are available seven days a week to give you the peace of mind. We’re always here if you need us.
Seven great reasons why you should choose WMS Site AssistTM
1 2 3 4 5 6 7
Our Design
We designed your system in the first place so we know exactly how it is designed and configured.
Our Products
Our products are made by recognised European manufacturers to our own high specification.
Our Installation
All our systems are installed by our own teams of CSCS trained engineers.
Our Engineers
We train our engineers to the highest standards to fit our systems. We do not fit other systems and no-one else fits our systems.
Planned Maintenance
Planned maintenance makes the most financial sense in the long run because it ensures that your system will function efficiently and cost effectively well into the future.
Your Success
Our reputation really matters to us which is why we go to extraordinary lengths to make sure that our clients are delighted with the service that we provide.
Peace of Mind
With ‘Site Assist’ your system is in the hands of the experts. We designed, supplied and installed your system and our engineers know best how to maintain it to the highest standards.
46 | WMS Underfloor Heating
site a > Our Design > Our Products > Our Installation > Our Engineers > Our Planned Maintenance > Your Success > Peace Of Mind
Experience a higher level of service with ‘Site Assist’ aftercare and maintenance.
SITE ASSIST
site assist
st i s s
TM
WMS Underfloor Heating | 47
case stud 48 | WMS Underfloor Heating
dies
50 52 54 56 58 60 62 64 66 68 70 72
Fabrik, Coldharbour Lane, Brixton Primark, East Ham 3 City Place, Gatwick Holme Mills Heritage Centre Bishops Park, The Bishops Avenue Linton Park School Ashmolean Museum, Oxford St. Charles Sixth Form College Greater Manchester Police Authority HQ City of Westminster College The Cutty Sark, Greenwich Dagnall Farm Barns, Berkhamsted
WMS Underfloor Heating | 49
Fabrik, Coldharbour Lane, Brixton
The ‘Fabrik’ Coldharbour Lane development is the UK’s first ModernaHus development. ModernaHus is a pre-fabricated house building system that was originally developed by Skanska for the Scandinavian housing market which they have adapted for the UK. The main features of this project are a well-insulated building envelope combined with an underfloor heating system and a central biomass boiler which feeds a site-wide district heating scheme to provide a truly energy efficient and sustainable housing solution.
50 | WMS Underfloor Heating
CASE STUDIES SYSTEM AmbiTak CLIENT Notting Hill Housing trust ARCHITECTS Powell Dobson, Allford Hall Monaghan Morris CONTRACTOR Skanska UK Plc PROJECT VALUE £13 Million PROGRAMME 18 Months
This development consists of two eight storey blocks offering 108 affordable one, two, three and four bedroom homes to tenants over a mix of shared ownership and social rented properties. A key feature of this 5,497m2 development is its energy efficiency and sustainability. A well insulated building combined with underfloor heating results in reduced energy consumption, lower carbon emissions, improved living conditions and increased saleability. Each apartment in this development is up to 44% more energy efficient than standard homes.
The underfloor heating solution used is commonly known as the ‘tacker clip system’ and involves clipping the pipe work directly to a gridded plastic laminate which is pre-glued to an insulation layer. With this system the pipe can be laid in a spiral pattern to ensure an even distribution of heat. The whole installation took just seven weeks to complete, which is an average of four apartments per day. WMS also undertook the controls package, providing individual room temperature control and time control to the hot water system.
WMS Underfloor Heating | 51
Primark, East Ham, London
Primark is one of the UK’s most successful clothing retailers with over 220 stores in the UK, Ireland and Europe. Employing 36,000 people with a turnover of £2.7 billion, Primark has occupied a prime position on the British high street for the past decade.
52 | WMS Underfloor Heating
CASE STUDIES SYSTEM AmbiTak CLIENT Primark Stores Limited ARCHITECT IDL (EU) Ltd CONTRACTOR ISG Pearce Ltd PROJECT VALUE ÂŁ9.5 million PROGRAMME 54 weeks
The project involved the construction of a two storey extension to Primark’s existing store. Structural changes were made to accommodate new goods and customer lift shafts. Additional escalator pits were also dug out for future development and a new service yard and goods loading area were also constructed. Total floor area was increased by 3,328m2 over two floors comprising both retail space and storage areas. The architects wanted a heating system that provided comfortable and
uniform heating across large areas without encroaching on the retail space. Underfloor heating matched these requirements perfectly and it quickly became the preferred choice for this project. WMS used an in-screed AmbiTak system to provide the uniform temperatures required, combined with superior quality Ambiente control systems allowing for variable temperature control to all areas.
WMS Underfloor Heating | 53
3 City Place, Gatwick
The City Place development consisted of the design and construction of a new high quality four storey office block, providing a clean working area to over 500 personnel. The majority of its structure was made up of glass, with panels extending from floor to ceiling on each level creating an open and spacious impression as well as providing plenty of natural daylight.
54 | WMS Underfloor Heating
CASE STUDIES SYSTEM AmbiAF + AmbiClip CLIENT BAA Lynton Ltd ARCHITECT Hamilton Architects Ltd CONTRACTOR Bowmer and Kirkland Ltd PROJECT VALUE ÂŁ9.9 Million PROGRAMME 12 Months
The building is built in accordance with modern environmentally-friendly standards and is highly selfsustainable and energy efficient. However, energy efficiency is only acceptable when the design leads to a comfortable, healthy working environment. Underfloor heating was considered to be the natural choice for this construction, providing a significantly more cost effective and eco friendly solution as opposed to more traditional heating systems.
Robust, 17mm diameter PE-RT pipe was used throughout this installation. The pipe has 2mm thick walls and is made up of five layers with an internal and external oxygenation barrier to prevent water ingress into the system. It is guaranteed for 50 years although we would expect it to outlive the life of most buildings.
The underfloor installation comprised of our superior AmbiClip screeded floor system, laid over a polythene separating layer and 80mm Celotex insulation on top of the concrete subfloor. The main office areas utilised an access floor allowing for services to run unhindered beneath.
WMS Underfloor Heating | 55
Holme Mills Heritage Centre
Holme Mills Heritage Centre is an original mill that has existed for over 1000 years and is located on the banks of the River Ivel in Bedfordshire. The Mills are a feature of sustainability with all its history in the growing of grain and vegetables. The structure is made from natural timber with many original beams and lathe and plaster render to the surfaces. This historic building has now been developed into an energy efficient market gardening visitor centre with interactive displays, a cafe, a shop and offices. 56 | WMS Underfloor Heating
CASE STUDIES SYSTEM AmbiClip + Bespoke CLIENT The Jordans & Ryvita Company Limited ARCHITECT Roderick James Architects Limited CONTRACTOR Molina Projects Limited PROJECT VALUE £9.5 million PROGRAMME 12 months
The building boasts over 4.5Km of high performance, 17mm underfloor heating pipe working alongside the latest technology Ambiente manifold sets. Individual, computerised room temperature and timer controllers are located throughout the building with strategically placed room temperature sensors situated in all areas. WMS used an AmbiClip system for the ground floor with a 75mm fibre screed overlay which was power floated to a smooth finish. For the underlying insulation we used a 100mm polyurethane Celotex board with foil on both sides to maximise the reflection of heat upwards. A damp proof membrane/separating layer was laid underneath to prevent moisture permeating through the floor.
WMS designed a bespoke solution for the upper floors with a hybrid screeded floor between timber joists. This had excellent thermal efficiency and maximised output. The system was connected to a state of the art heat pump and operates with various set points including an outside weather compensating control where the temperature of the flow is varied in relation to ambient air temperature. The PE-RT five layer UFH pipe used has a 50 year guarantee and reflects both the building’s intrinsic ‘long lasting quality and sustainability’ and the ethical commitment of Jordans to secure this important building for the long term.
WMS Underfloor Heating | 57
Bishops Park, The Bishops Avenue
Bishops Park is situated off The Bishops Avenue. It is one of London’s most sought after addresses. The development consists of 24 luxury apartments and three magnificent penthouses with private gated grounds of almost two acres that include woodland with mature cedar trees.
58 | WMS Underfloor Heating
CASE STUDIES SYSTEM AmbiTak CLIENT Bishops Avenue Property Company ARCHITECT Moxley Architects Ltd CONTRACTOR Octagon Developments Ltd PROJECT VALUE ÂŁ30 Million PROGRAMME 24 Months
The classic design layout and interplay of natural daylight give a unique sense of space in each apartment, raising the standard of living to a new level of enjoyment. Terraces and balconies are generously proportioned and afford timeless views across the neighbouring countryside. The property also benefits from an underground car park served by lifts to each floor.
assisted the developer by reducing the stress and responsibility that is normally involved in coordinating a number of trades. If you are striving to make your new development just that little bit superior, contact our friendly sales team who will guide and assist you through the procedures.
To complement this prestigious development, WMS Underfloor Heating was chosen to supply a system that was capable of providing exceptional comfort and control. WMS was contracted to construct the whole floor build up from laying the acoustic detail through to screeding. The turnkey contract
WMS Underfloor Heating | 59
Linton Park School
Linton Park School is a fully self contained unit situated in the rural suburbs of Maidstone, Kent. It provides schooling from year three through to year 13, and achieves very high academic standards due to the environment created for both staff and pupils.
60 | WMS Underfloor Heating
CASE STUDIES SYSTEM AmbiTak CLIENT Medway Education Trust ARCHITECT Folkes Architects CONTRACTOR Linton Projects Ltd PROJECT VALUE ÂŁ2.5 Million PROGRAMME 10 Months
The Architects involved were looking for a heating system that did not encroach on the teaching space as well as achieving maximum comfort, and wanted to maintain environmental standards at all costs. Underfloor heating was the only solution. The whole school was heated through the floor by a tacker system on top of a 50mm laminated polystyrene insulation. The 1,600m2 main building had a tight deadline with the entire system having to be installed in three days! WMS were able to achieve this without compromising our high quality of service.
The private school’s artificial sports ground supports its success in a wide variety of team games and individual sports. It also boasts a separate 250m2 music tutorial building, which contributes to the standards of schooling held to. WMS have provided heating solutions in many educational buildings and are familiar with the requirements, quality of service, and flexibility of timescales they require. We have a team of technical advisors to assist you as to every aspect of your project. We look forward to receiving your enquiry.
WMS Underfloor Heating | 61
Ashmolean Museum, Oxford
The Ashmolean is the most important museum of art and archaeology in this country outside London. It is the oldest museum in Europe and has collections of great national and international importance. It is housed, in part, in one of the finest Greek revival buildings in the British Isles.
‚ All images are copyright property of Ashmolean Museum, University of Oxford. 62 | WMS Underfloor Heating
CASE STUDIES SYSTEM AmbiClip CLIENT Oxford University Fixed Assets Ltd ARCHITECT Rick Mather Architects CONTRACTOR BAM Construction Ltd PROJECT VALUE ÂŁ46 Million PROGRAMME 9 Months
Designed by Charles Cockerell in 1845, this Grade I listed building is retained as the frontage for the new museum. The museum plays a key role in Oxford University’s policy of wider access as well as supporting university teaching and research. The project consists of 8,812m2 of new build area, representing a 91% increase in area. The building is arranged over six floors including an excavated lower ground floor level. The spaces created are of high quality and serviced to meet modern museum standards. Underfloor heating was used to heat part of the refurbishment in the form of our AmbiClip screed floor system. The even and gentle form of temperature control that underfloor heating provides made it a natural choice of heating.
The building comprises 37 new gallery spaces for the permanent collection in addition to special exhibitions, a two-storey education centre with designated entrance, office space for the curatorial and administration departments, study collection spaces for the public to view objects by appointment, a new loading bay and transit store for the secure and dry transportation of artifacts and exhibitions, conservation studios and ancillary facilities.
WMS Underfloor Heating | 63
St. Charles Sixth Form College
The project involved the demolition of a sports hall to provide space for a new classroom block, sports facilities and the refurbishment of a multiuse games area.
64 | WMS Underfloor Heating
CASE STUDIES SYSTEM AmbiPlate 30 CLIENT St Charles Sixth Form College ARCHITECT Studio E CONTRACTOR Galliford Try Construction PROJECT VALUE £5.2 Million PROGRAMME 9 Months
The new facilities feature cross-laminated timber frame and walls, a balustrade staircase with stainless steel mesh and maple wood handrail, cladding and glazing. Energy renewable aspects include rainwater harvesting, a ground source heat pump – utilising buried coils and thermal roof panels, working along with underfloor heating. The main focal point of the building is the state of the art solar shading panels on the exterior and roof.
As every new build school has to comply with the relevant environmental standards and regulations, underfloor heating has become increasingly popular. Running costs have been proved to be up to 30% cheaper than the conventional radiator systems, as well as a generally cleaner and safer form of heating. The practical application of keeping the wall space free from any surface wall heaters is another added benefit.
Many cost saving innovations were used on the build including the use of Kingspan timber panelling. The College has been awarded BREEAM rating – VERY GOOD. The fact that underfloor heating systems work at lower temperatures and stay on for longer periods lends itself towards the renewable heat pump technology.
WMS Underfloor Heating | 65
Greater Manchester Police Authority HQ
This striking 21,832m2 six storey building for Greater Manchester Police Authority (GMPA) replaced the old force headquarters at Trafford Park. Completed in 2011, the building accommodates up to 1,500 staff and includes the Counter Terrorism Unit.
66 | WMS Underfloor Heating
CASE STUDIES SYSTEM AmbiTak CLIENT Greater Manchester Police Authority ARCHITECT Aedas CONTRACTOR Carillion PROJECT VALUE £63.7 Million PROGRAMME 24 Months
The six-storey building is a highly sophisticated office building, with a BREEAM rating of Excellent, supporting modern day policing requirements and ensuring a smarter, more effective work force. Coloured glass and stone are key features of the six-storey building, which is visible from Piccadilly in the centre of Manchester. The building features a central atrium surrounded by open plan offices which is designed to encourage interaction between departments and strengthen communication.
heating system within a 97mm screed that was able to operate in both heating and cooling mode for the reception and central atrium area of the building. GMPA Chairman Cllr Paul Murphy said: “This new HQ building will be the most modern, fit-for-purpose police building in the UK and that is something GMPA is extremely proud of. A project of this scale and size takes an incredible amount of hard work and commitment from everyone involved”.
The environmentally friendly design from architects Aedas is also designed to reduce running costs. As part of this sustainable approach to running costs, WMS were asked to supply and install an Ambiente underfloor
WMS Underfloor Heating | 67
City of Westminster College
This flagship campus for City of Westminster College by Schmidt Hammer Lassen architects is designed to support new ways of teaching and learning. The RIBA award winning 24,000m2 College contains far more open learning space than typical colleges in the UK as well as providing state-of-the-art laboratories, meeting rooms, cafes, a 140 seat theatre and a large sports hall.
68 | WMS Underfloor Heating
CASE STUDIES SYSTEM AmbiPlate CLIENT City of Westminster College ARCHITECT Schmidt Hammer Lassen CONTRACTOR McLaren Construction Limited PROJECT VALUE ÂŁ70 million PROGRAMME 24 months
The building is designed to be highly energy efficient. The overall scheme has a low maintenance liability which is designed to significantly reduce the building’s running costs and carbon footprint. WMS installed a plated system within the sports hall as it had to fit within a specialist sports floor system. The 17mm, PE-RT Ambiente pipe was fitted into pre-grooved aluminium plates installed between the timber sprung battens.
This system offered a perfect solution to the floor build up specified, as well as providing exceptional comfort and temperature control for the varied activities taking place in the hall without encroaching on wall space. WMS was able to facilitate this due to many years of specialist experience in providing underfloor heating solutions for schools, colleges, academies and universities.
WMS Underfloor Heating | 69
Cutty Sark, Greenwich
Cutty Sark is the most famous tea clipper ever built and is the only one to survive. Built in 1869 and named after a fleet-footed witch in the Scottish legend of Tam O’Shanter, the ship was almost destroyed by fire in 2007. Following lottery funding and public donations it was decided to conserve the ship to its former glory and build an imaginative new visitor centre at the ship’s home in Greenwich Dock.
70 | WMS Underfloor Heating
CASE STUDIES SYSTEM Bespoke CLIENT Cutty Sark Trust ARCHITECT Grimshaw Architects LLP CONTRACTOR SH Structures PROJECT VALUE £50 Million PROGRAMME November 2006 to April 2012
The project involved raising the 980 tonne ship by over three metres and constructing a glass canopy over the dry berth to protect the ship’s hull from the elements. This allows visitors to view the clipper’s uniquely shaped ‘built for speed’ hull from below. The new facility also has an indoor shopping area and a cafe. Due to the unusual floor construction in the dry berth area, underfloor heating panels were specially designed by WMS engineers. The installation featured a bespoke, raised floor
build up supported by pedestals holding large calcium sulphate pre-grooved boards to allow the underfloor heating pipe work to be laid flush within each panel. This provided a completely floating floor slab that as the primary heat source, capable of achieving at least 70 watts per metre. This is a unique design and was created by WMS designers using our experience and knowledge of underfloor heating and its wide range of applications.
WMS Underfloor Heating | 71
Dagnall Farm Barns, Berkhamsted
A six barn conversion development and two new build semi-detached three bedroom houses create this high specification, rural development from TC Limited. With exposed beams, high ceilings and a requirement to create open-plan living spaces, underfloor heating quickly became the preferred choice of heating.
72 | WMS Underfloor Heating
CASE STUDIES SYSTEM AmbiTak CLIENT TC Limited ARCHITECT Akaal Associates Limited CONTRACTOR TC Limited PROJECT VALUE 1.8 Million PROGRAMME 12 Months
A combination of laminated oak flooring and carpeting were laid to the living areas and bedrooms and ceramic tiles to the kitchen and bathrooms. With no radiators taking up wall space, the system allows for complete interior design and decoration flexibility. A system of carefully positioned thermostats ensures precise control of individual room temperatures. WMS supplied an efficient fixed low temperature solution with their usual consistent quality and meeting a range of varying outputs that were required throughout each property. WMS worked to a lean timescale on this project and completed on-time and within budget.
WMS Underfloor Heating | 73
Support Centres We have a comprehensive UK presence with offices and distribution centres in the South East, Midlands, Hampshire and Scotland. Our head office is situated near the A1 at Bell Bar, just north of London.
Head Office WMS Underfloor Heating Heritage House 1 Woodside Lane Bell Bar Hertfordshire, AL9 6DE Telephone 01707 64 99 22 Fax 01707 65 89 67 Email sales@wms-uk.com www.wms-uk.com
74 | WMS Underfloor Heating
ACCREDITATIONS
Accreditations and Quality Standards We take our role as a leading supplier of underfloor heating systems very seriously, from both a client and user perspective and as responsible and safe contractors. Company Wide Accreditations
Product Accreditations
WMS Underfloor Heating | 75
EDITION 04
Commercial | Retail | Housing | Educational | Health
L634 [56.49]
X UNICLASS L75627
WMS Underfloor Heating
Underfloor Heating. Your Perfect Partners
WMS Underfloor Heating Heritage House 1 Woodside Lane Bell Bar AL9 6DE Telephone 01707 64 99 22 Fax 01707 65 89 67 Email sales@wms-uk.com www.wms-uk.com
WMS
Underfloor Heating
WMS
Underfloor Heating