by THOR BUILDING PRODUCTS
www.thorbuilding.com.au
RHINO is a trusted brand in the building industry known for Quality Products, Service & Support. Proudly Owned & Manufactured in Australia for 15 years
Thor Building Products Pty Ltd HEAD OFFICE 293 Earnshaw Rd Northgate QLD 4013 MANUFACTURING PLANT 32 Lysaght St Acacia Ridge QLD 4110 T: 1300 880 828 F: 07 3219 6833 E: info@thorbuilding.com.au W: www.thorbuilding.com.au ABN 12 088 560 392 HIA 8 6 5 4 8 3
Section 1 GLASSWOOL Rhino glasswool batt insulation range Section 2 BLANKET Rhino blanket range
by THOR BUILDING PRODUCTS
Section 3 POLYESTER Rhino white polyester batt range Section 4 CELL RANGE Rhino cell range Section 5 FOAM Rhino foam range Section 6 WRAP & FOIL Rhino wrap reflective foil range Section 7 PIR BOARD Rhino PIR board range Section 8 ROCKWOOL Other wall & surface insulation products Section 9 ACCESSORIES
RHINO is a trusted brand in the building industry known for Quality Products, Service & Support. Proudly Owned & Manufactured in Australia for 15 years
by THOR BUILDING PRODUCTS
Section 1 RHINO GLASSWOOL BATT INSULATION RANGE • Rhino Batts Rhino Wall & Celling Batts provide a thermal and acoustic barrier for energy-efficient construction. • Rhino Partition Batts Commercial acoustic and thermal insulation in steel stud framing for multi-residential and commercial steel frame buildings • Rhino Partition Batts Commercial acoustic and thermal insulation
Technical Data Sheet NEXT GENERATION FORMULA With a softer feel for more comfortable handling
AS/NZS 4859.1: 2002 Including Amendment 1 Materials for the Thermal Insulation of Buildings RHINO Partition Batts products comply with the Energy Efficiency provisions of the BCA for all types of thermal insulation to be certified by a NATA accredited organisation.
RHINO Partition Batts Commercial acoustic and thermal insulation Product description and typical applications RHINO Partition Batts is a lightweight, glasswool product specially designed to be free standing for quick installation in steel stud framing for multi-residential and commercial steel frame buildings. All products are designed to give assurance of effective sound absorption and to reduce noise transfer between rooms. Whilst effectively providing solutions to ‘problem’ acoustic applications, RHINO Partition Batts also provides a range of thermal values making the products suitable for insulating the external walls of a building envelope thereby increasing the comfort levels of building occupants. RHINO Partition Batts features a Next Generation formula that provides a softer feel for more comfortable handling.
Physical characteristics Material R-value
Nominal thickness
R1.2
50
R1.8
75
R2.1
90
R1.3
50
R1.9
75
R2.2
90
R0.7 R1.1
25 38
R1.4
50
R1.8
64
R2.1
75
R2.5
90
R2.8
100
R1.5
50
R2.2
75
R2.7
90
R3.0
100
Batt size mm
Pieces per pack
RHINO Partition 12 Insulation 1200 x 450 32 2700 x 450 24 1200 x 600 32 2700 x 600 16 1200 x 450 16 2700 x 450 24 1200 x 600 16 2700 x 600 16 1200 x 450 16 2700 x 450 24 1200 x 600 16 2700 x 600 16 RHINO Partition 14 Insulation 1200 x 450 24 2700 x 450 24 1200 x 600 24 2700 x 600 16 1200 x 450 16 2700 x 450 18 1200 x 600 16 2700 x 600 12 1200 x 450 14 2700 x 450 15 1200 x 600 10 2700 x 600 10 RHINO Partition 24 Insulation 2700 x 600 20 2700 x 600 12 1200 x 450 12 1200 x 600 12 2700 x 600 12 2700 x 600 10 1200 x 450 10 1200 x 600 10 1200 x 450 8 1200 x 600 8 1200 x 450 6 1200 x 600 6 RHINO Partition 32 Insulation 1200 x 450 12 1200 x 600 12 1200 x 450 10 1200 x 600 10 1200 x 450 8 1200 x 600 8 1200 x 450 6 1200 x 600 6
Area per pack m2
Product code
17.3 29.2 25.0 25.9 8.6 29.2 11.5 25.9 8.6 29.2 11.5 25.9
RPBatt-50-11-1245 RPBatt-50-11-2745 RPBatt-50-11-1260 RPBatt-50-11-2760 RPBatt-75-11-1245 RPBatt-75-11-2745 RPBatt-75-11-1260 RPBatt-75-11-2760 RPBatt-90-11-1245 RPBatt-90-11-2745 RPBatt-90-11-1260 RPBatt-90-11-2760
13.0 29.2 17.3 25.9 8.6 21.9 11.5 19.4 7.6 18.2 7.2 16.2
RPBatt-50-14-1245 RPBatt-50-14-2745 RPBatt-50-14-1260 RPBatt-50-14-2760 RPBatt-75-14-1245 RPBatt-75-14-2745 RPBatt-75-14-1260 RPBatt-75-14-2760 RPBatt-90-14-1245 RPBatt-90-14-2745 RPBatt-90-14-1260 RPBatt-90-14-2760
32.40 19.40 6.50 8.60 19.40 16.20 5.40 7.20 4.30 5.80 3.20 4.30
RPBatt-25-24-2760 RPBatt-38-24-2760
6.5 8.6 5.4 7.2 4.3 5.8 3.2 4.3
RPBatt-50-24-2760 RPBatt-64-24-2760
RPBatt-50-32-1245 RPBatt-50-32-1260 RPBatt-75-32-1245 RPBatt-75-32-1260
Technical Data Sheet NEXT GENERATION FORMULA With a softer feel for more comfortable handling
Acoustic performance predictions FIBRE CEMENT CLAD STEEL STUD WALL SYSTEM
5
1
1. 2. 3. 4. 5. 6. 7.
7.5mm (R0.1) lightweight cladding Unventilated 35mm airspace Reflective insulation material 35mm battens 90mm RHINO Partition 24 insulation 92mm steel stud 10mm plasterboard
6
2
7 3 AS/NZS 4859.1: 2002 Including Amendment 1 Materials for the Thermal Insulation of Buildings RHINO Partition insulation products comply with the Energy Efficiency provisions of the BCA for all types of thermal insulation to be certified by a NATA accredited organisation.
Sound Reduction Index (Rw) 48
4
The Rw estimated tolerance is +/- 3dB.
METAL CLAD STEEL STUD WALL SYSTEM
5 1
1. 2. 3. 4. 5. 6. 7.
Steel cladding Unventilated 35mm airspace Reflective insulation material 35mm battens 90mm RHINO Partition 32 insulation 92mm steel stud 10mm plasterboard
6
2
7 3
Sound Reduction Index (Rw) 41
4
The Rw estimated tolerance is +/- 3dB.
INTERNAL STEEL FRAME PARTITION WALL 1. 2. 3. 4.
10mm plasterboard 92mm steel stud 90mm RHINO Partition 14 Insulation 10mm Plasterboard
1
2
4
3
Sound Reduction Index (Rw) 42
The Rw estimated tolerance is +/- 3dB.
Technical Data Sheet NEXT GENERATION FORMULA With a softer feel for more comfortable handling
AS/NZS 4859.1: 2002 Including Amendment 1 Materials for the Thermal Insulation of Buildings RHINO Partition insulation products comply with the Energy Efficiency provisions of the BCA for all types of thermal insulation to be certified by a NATA accredited organisation.
Installation guidelines TOOLS REQUIRED: • Curved blade knife with plastic handle (non-conductive handle) • For high density batts a serrated knife with a plastic handle is recommended • Knife holster to quickly access the knife • Industrial strength ladder • Tape measure • Safety eye wear • Safety shoes BEFORE YOU COMMENCE: Turn off the power at the fuse box before commencing the installation. Ensure you place a warning tag to prevent power being restored prior to completion of the install. Be aware that your electrical appliances will not be operational during this time. Use only RHINO Partition insulation, recommended according to the type and thickness of the stud. BRICK VENEER: • and studs or noggins. • It is important that the insulation is secured so it cannot fall into the cavity or come in contact with the outer brickwork allowing moisture to pass from the exterior wall to the internal lining. • installing the insulation from the inside. • et of studs from the top to the bottom, running parallel with the studs. Where two lengths are used they should be evenly spaced. • around water pipes or other rigid obstructions in the wall. FIBRE CEMENT OR WEATHERBOARD CLADDING: • A breather (low vapour barrier) wall wrap or building paper must be used so as not to cause moisture build up. • Butt the insulation closely together to ensure there are no gaps left at joints.
CAVITY BRICK WALLS (DOUBLE BRICK): • RHINO Partition insulation is not recommended for use in cavity brick construction. INTERNAL PARTITION WALLS: • and studs or noggins. • For comprehensive details, please refer to Australian Standard 3999. CAUTION: Electric cables and equipment partially or completely surrounded with bulk thermal insulation may overheat and fail. This applies to wiring installed prior to 1989. Refer to AS39991992 including Amendment 1: Section 2.6 for details. Cabling post 1989: continuous electrical cabling (240 volts) cannot be fully surrounded by the insulation for a length greater than 300mm. In runs greater than 300mm, the electrical wiring must be touching a timber stud or the plaster lining.
Green Star compliant RHINO Partition Insulation does not use Ozone Depleting Potential (ODP) substances in the manufacture or composition of its FBS-1 Glass Wool Bio-Soluble Insulation ® and Sisalation® reflective foil products using insulation with an ODP of zero will accrue one Green Star point under the Insulant ODP Credit for eligible Green Star projects. The use of these RHINO Partition Insulation products guarantees the use of ODP free insulation while also ensuring that no harmful levels of Volatile Organic Compounds (VOCs) are released. This allows the incorporation of environmentally preferable insulation whilst also maintaining indoor air quality.
Technical Data Sheet NEXT GENERATION FORMULA With a softer feel for more comfortable handling
AS 1530.1-1994 Test for combustibility of materials Testing conducted by CSIRO in accordance with AS1530.1concluded that all 11-32kg/m3 RHINO Partition insulation products are non-combustible. The National Construction Code (NCC) deemed to satisfy provisions require walls important to the structural integrity of commercial buildings to be constructed wholly of materials that are non-combustible. Fire rated walls between tenancies and common walls of multi-level apartment buildings must also be constructed wholly of materials that are non-combustible. The NCC states that if materials used in an assembly contain combustible components, then the assembly is combustible. Therefore incorporating non-combustible RHINO Partition insulation into wall systems allows users to obtain the products thermal and acoustic benefits whilst complying with the NCC requirement to maintain a buildings structural integrity.
AS/NZS 1530.3-1999 Early fire hazard properties of materials AS/NZS 4859.1: 2002 Including Amendment 1 Materials for the Thermal Insulation of Buildings RHINO Partition insulation products comply with the Energy Efficiency provisions of the BCA for all types of thermal insulation to be certified by a NATA accredited organisation.
RHINO Partition insulation exhibits the following characteristics when tested in accordance with AS1530.3. Ignitability Index
0
Spread of Flame Index
0
Heat Evolved Index
0
Smoke Developed Index
0-1
Moisture Absorption In the event of RHINO Partition Batts becoming wet, it should be dried prior to installation to obtain maximum performance and prevent damage to other building elements. RHINO Partition insulation absorbs less than 0.2% moisture by volume when exposed to environmental conditions of 50˚C and 95% relative humidity for four days.
Alkalinity When tested in accordance with British Standard 3958, Fletcher Insulation™ glasswool products are slightly alkaline ph9 (neutral is ph7). They will not promote or accelerate the corrosion of steel or galvanised steel studs provided they are protected from external contamination.
Maximum Service Temperature RHINO Partition Batts have a maximum service temperature of 340˚C.
Specification notes State the following: • Product name i.e. RHINO Partition Batts followed by the relevant density i.e. RHINO Partition 11, 14, 24 or 32. • Material R-value required and/or thickness required • Joist or stud spacing • Area involved
Thor Building Products P/L 293 Earnshaw Road - Northgate QLD 4013 PH
1300 880 828
sales@thorbuilding.com.au www.thorbuilding.com.au
RHINO Partition Batts - Data Sheet: RHINO Partition Batts are a lightweight, glasswool product specially designed to be free standing for quick installation in steel stud framing for multi-residential and commercial steel frame buildings.
RHINO PARTITION BATTS Commercial acoustic and thermal insulation Product description and typical applications RHINO Partition Batts is a lightweight, glasswool product specially designed to be free standing for quick installation in steel stud framing for multi-residential and commercial steel frame buildings. All products are designed to give assurance of effective sound absorption and to reduce noise transfer between rooms. Whilst effectively providing solutions to ‘problem’ acoustic applications, RHINO Partition Batts also provides a range of thermal values making the products suitable for insulating the external walls of a building envelope thereby increasing the comfort levels of building occupants. RHINO Partition Batts features a soft feel for more comfortable handling.
23.1
Data Sheet RHINO PARTITION BATTS Acoustic performance predictions
FIBRE CEMENT CLAD STEEL STUD WALL SYSTEM 1. 7.5mm (R0.1) lightweight cladding 2. Unventilated 35mm airspace 3. Reflective insulation material 4. 35mm battens 5. 90mm RHINO Partition 24 insulation 6. 92mm steel stud 7. 10mm plasterboard
Sound Reduction Index (Rw) 48 The Rw estimated tolerance is +/- 3dB.
METAL CLAD STEEL STUD WALL SYSTEM 1. Steel cladding 2. Unventilated 35mm airspace 3. Reflective insulation material 4. 35mm battens 5. 90mm RHINO Partition 32 insulation 6. 92mm steel stud 7. 10mm plasterboard
Sound Reduction Index (Rw) 41 The Rw estimated tolerance is +/- 3dB.
INTERNAL STEEL FRAME PARTITION WALL 1. 10mm plasterboard 2. 92mm steel stud 3. 90mm RHINO Partition 14 Insulation 4. 10mm Plasterboard
Sound Reduction Index (Rw) 42 The Rw estimated tolerance is +/- 3dB
Data Sheet
Installation guidelines TOOLS REQUIRED: • Curved blade knife with plastic handle (non-conductive handle) • For high density batts a serrated knife with a plastic handle is recommended • Knife holster to quickly access the knife • Industrial strength ladder • Tape measure • Safety eye wear • Safety shoes BEFORE YOU COMMENCE: Turn off the power at the fuse box before commencing the installation. Ensure you place a warning tag to prevent power being restored prior to completion of the install. Be aware that your electrical appliances will not be operational during this time. Use only RHINO Partition insulation, recommended according to the type and thickness of the stud.
BRICK VENEER: • Friction fit the Insulation into the wall frames ensuring there are no gaps between the insulation and studs or noggins. • It is important that the insulation is secured so it cannot fall into the cavity or come in contact with the outer brickwork allowing moisture to pass from the exterior wall to the internal lining. • Wall wrap or long lasting string/twine should be fixed across the exterior face of the frame before installing the insulation from the inside. Where string/twine is used, twine should be fixed between each set of studs from the top to the bottom, running parallel with the studs. Where two lengths are used they should be evenly spaced. •Ensure that the batts do not protrude past the stud and fit snugly including where insulation is around water pipes or other rigid obstructions in the wall. FIBRE CEMENT OR WEATHERBOARD CLADDING: • A breather (low vapour barrier) wall wrap or building paper must be used so as not to cause moisture build up. • Butt the insulation closely together to ensure there are no gaps left at joints. • Offcuts may be used to fill small spaces to ensure complete coverage. CAVITY BRICK WALLS (DOUBLE BRICK): • RHINO Partition insulation is not recommended for use in cavity brick construction. INTERNAL PARTITION WALLS: • Friction fit the Insulation into the wall frames ensuring there are no gaps between the insulation and studs or noggins. • Ensure that the batts do not protrude past the stud and fit snugly For comprehensive details, please refer to Australian Standard 3999. CAUTION: Electric cables and equipment partially or completely surrounded with bulk thermal insulation may overheat and fail. This applies to wiring installed prior to 1989. Refer to AS39991992 including Amendment 1: Section 2.6 for details. Cabling post 1989: continuous electrical cabling (240 volts) cannot be fully surrounded by the insulation for a length greater than 300mm. In runs greater than 300mm, the electrical wiring must be touching a timber stud or the plaster lining. Green Star compliant: RHINO Partition Insulation does not use Ozone Depleting Potential (ODP) substances in the manufacture or composition of its FBS-1 Glass Wool Bio-Soluble Insulation ® and Sisalation® reflective foil products using insulation with an ODP of zero will accrue one Green Star point under the Insulant ODP Credit for eligible Green Star projects. The use of these RHINO Partition Insulation products guarantees the use of ODP free insulation while also ensuring that no harmful levels of Volatile Organic Compounds (VOCs) are released. This allows the incorporation of environmentally preferable insulation whilst also maintaining indoor air quality.
Data Sheet
AS 1530.1-1994 Test for combustibility of materials
Testing conducted by CSIRO in accordance with AS1530.1 concluded that all 11-32kg/m3 RHINO Partition insulation products are non-combustible. The National Construction Code (NCC) deemed to satisfy provisions require walls important to the structural integrity of commercial buildings to be constructed wholly of materials that arenon-combustible. Fire rated walls between tenancies and common walls of multi-level apartment buildings must also be constructed wholly of materials that are non-combustible. The NCC states that if materials used in an assembly contain combustible components, then the assembly is combustible. Therefore incorporating non-combustible RHINO Partition insulation into wall systems allows users to obtain the products thermal and acoustic benefits whilst complying with the NCC requirement to maintain a buildings structural integrity.
AS/NZS 1530.3-1999 Early fire hazard properties of materials RHINO Partition insulation exhibits the following characteristics when tested in accordance with AS1530.3.
Ignitability Index
0
Spread of Flame Index
0
Heat Evolved Index
0
Smoke Developed Index
0-1
Moisture Absorption In the event of RHINO Partition Batts becoming wet, it should be dried prior to installation to obtain maximum performance and prevent damage to other building elements. RHINO Partition insulation absorbs less than 0.2% moisture by volume when exposed to environmental conditions of 50˚C and 95% relative humidity for four days.
Alkalinity When tested in accordance with British Standard 3958, Fletcher Insulation™ glasswool products are slightly alkaline ph9 (neutral is ph7). They will not promote or accelerate the corrosion of steel or galvanised steel studs provided they are protected from external contamination.
Maximum Service Temperature RHINO Partition Batts have a maximum service temperature of 340˚C.
Specification notes State the following: • Product name i.e. RHINO Partition Batts followed by the relevant density i.e. RHINO Partition 11, 14, 24 or 32. • Material R-value required and/or thickness required • Joist or stud spacing • Area involved
Thor Building Products P/L 293 Earnshaw Road - Northgate QLD 4013 PH 1300 880 828 sales@thorbuilding.com .au www.thorbuilding.com .au
by THOR BUILDING PRODUCTS
Section 2 RHINO BLANKET INSULATION RANGE • Rhino Blanket Reflective foil laminate blanket intended for both thermal and acoustical applications • Rhino Facing Foil Rhino Blanket Facing reflective foil face faces down toward the air space under the roof and prevents airborne moisture from reaching the surface of the roof cladding, made with a high strength polywoven fabric facing which is applied to a glasswool blanket.
Proudly Manufactured by
RHINO BLANKET Information Technology Solutions
Thor Building Products P/L
Excellent thermal & acoustic insulation Highly resilient insulation Can be used with timber & metal frame Consistent quality Superior finished aesthetics
AS/NZS 4859.1:2002
Cost-effective
Bio-soluble
Thermal Conductivity
Non-combustible blanket fibres
BCA Compliant
ASTM C 518 AS/NZS 4859.1: 2002
TRADE preferred
low VOC-emitting
PER FO RM AN CE
Thermal Resistance ASTM C 653 AS/NZS 4859.1: 2002
TE CH N ICA L DA T A Water Vapor Absorption (ASTM C 1104)
THERMAL INSULATION WITH CONDENSATION
Application
CONTROL
Designed for application under metal, fibre cement, and
Rhino Blanket combines the thermal efficiency of spun
concrete roof cladding Rhino Blanket eliminates the
glass fibre with a laminate of reflective foil which not only
problems associated with condensation build up on the
further enhances the thermal efficiency of the system but
underside of the roof cladding. The reflective foil face
also serves to act as a dust and moisture barrier.
faces down toward the air space under the roof and prevents airborne moisture from reaching the surface of
Description
the roof cladding.
Rhino Blanket is intended for both thermal and
Rhino Blanket also performs as an acoustic insulative
acoustical applications. It is made from highly resilient,
barrier. It reduces noise from outside the home, such as
No greater than sterile cotton
inorganic glass fibres.
rain and from within the home by absorbing reverberant
Microbial Growth (ASTM C 1338)
Specification Compliance
Does not support microbial growth
AS/NZS 4859.1: 2002 Materials used in the
Fire Resistance (ASTM C 136)
Thermal Insulation of Buildings and complies with the
Less than 5% by weight
Manufactured by
Corrosion Resistance (ASTM C 665)
noise. Rhino Blanket’s bulk insulation blanket is made from non-combustible fibres and meets the BAL requirement for metal clad roofs in bushfire areas.
Building Code of Australia (BCA) requirements.
Facing Options
Non-combustible
The Duty Rating, Colour and Material Finish used to face
Bio-Solubility
Rhino Blanket can be varied to suit your application.
Rhino Blanket rolls are manufactured from bio-soluble
1300 880 828
(07) 3219 6833 SALES@THORBUILDING.COM.AU
293 EARNSHAW ROAD PO BOX 14 NORTHGATE QLD 4013 WWW.THORBUILDING.COM.AU
Other Thor Brands:
Details upon request.
fibres. Bio-soluble fibres have been extensively researched and shown to pose no long term health risk.
FOIL FACED:
Product Code
Thickness
R-Value
Dimensions *
Rolls
m2
(mm)
(m2 K/W)
(mm)
per pack
per pack
RB-R1.3-55
55
1.3
1200 x 15000
1
18
RB-R1.5-60
60
1.5
1200 x 15000
1
18
RB-R1.8-75
75
1.8
1200 x 15000
1
18
RB-R2.3-100
100
2.3
1200 x 10000
1
12
RB-R2.5-100
100
2.5
1200 x 10000
1
12
RB-R3.0-130
130
3.0
1200 x 10000
1
12
RB-R3.2-130
130
3.2
1200 x 10000
1
12
RB-R3.6-130
130
3.6
1200 x 6500
1
7.8
* Cut to size available on request UNFACED:
Product Code
TOTALLY AUSTRALIAN OWNED MANUFACTURED IN AUSTRALIA FROM LOCAL & IMPORTED COMPONENTS
Thickness
R-Value
Dimensions
Rolls
m2
(mm)
(m2 K/W)
(mm)
per pack
per pack
URB-R1.3-36
55
1.3
1200 x 30000
1
36.00
URB-R1.5-36
60
1.5
1200 x 30000
1
36.00
URB-R1.8-30
75
1.8
1200 x 25000
1
30.00
URB-R2.3-18
100
2.3
1200 x 15000
1
18.00
URB-R2.5-18
100
2.5
1200 x 15000
1
18.00
URB-R3.0-12
130
3.0
1200 x 10000
1
12.00
URB-R3.2-12
130
3.2
1200 x 10000
1
12.00
URB-R3.6-78
130
3.6
1200 x 6500
1
7.8
RHINO BLANKET FACING (HEAVY & EXTRA HEAVY DUTY)
PRODUCT INFORMATION Thor’s Blanket Facing is made with a high strength polywoven fabric facing which is applied to a glasswool blanket whilst other products commonly use a double sided foil with fibre mesh for the facing. The polywoven fabric provides the additional benefits of:
outstanding tensile and tear
Satisfy BCA specifications and Reflective Foil Laminates
Complies with the specifications and requirements of AS/NZS 4200.1 for "Pliable Building Membranes" which is a manual recognised by the BCA Part 3.5 Roof and Cladding
Low Flammability Index in accordance with AS 1530.2 ≤ 5
strength
unrolls more easily right the way to the end of the roll an excellent visible surface finish
requirements for
Satisfy BCA Part 3.7.1 Fire Hazard Properties Satisfy Health and Safety Regulations
APPLICATION Designed for application under metal, fibre cement, and concrete roof cladding Thor’s Blanket Facing eliminates the problems associated with condensation build up on the underside of the roof cladding. The reflective foil face faces down toward the air space under the roof and prevents airborne moisture from reaching the surface of the roof cladding. NOTE: Use in cold temperature climates (daytime <5oC) requires roof to be well ventilated and moist air from within the dwelling to be exhausted out into the atmosphere. FACING OPTIONS The Duty Rating, Colour and Material Finish of the blanket facing can be varied to suit your application.
Proudly Manufactured by
Thor Building Products P/L
1300 880 828
(07) 3219 6833 SALES@THORBUILDING.COM.AU 293 EARNSHAW ROAD PO BOX 14 NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
Colour
Gloss White
Gloss Silver-Grey
Matt Dark Blue
Duty
Extra Heavy
Heavy
Heavy
Width
1350
1350
1350
Residential & Commercial Insulation Vapour barrier Emittance Water barrier
High
High
High
Reflective
Reflective
Reflective
High
High
High
Low (≤5)
Low (≤5)
Low (≤5)
Tensile Strength Machine Direction (kN/m)
min 13.0
min 12.5
min 12.5
Tensile Strength Lateral Direction (kN/m)
min 10.5
min 7.5
min 7.5
Edge Tear Resistance Machine Direction (N)
min 90
min 80
min 80
Edge Tear Resistance Lateral Directions (N)
min 90
min 80
min 80
Water Vapour Transmission Rate (Ng/Ns)
max 2
max 2
max 2
max 0.05
max 0.05
max 0.05
Flammability Index UV treated non reflective face (not direct sunlight)
Emittance of Reflective Face
by THOR BUILDING PRODUCTS
Section 3 POLYESTER • Rhino White Wall & Ceiling Batts for thermal applications - 100% Polyester segments pre-cut to fit. • Rhino White Sound Batts and Rolls - 100% Polyester designed for timber framed residential and light commercial applications. • Rhino Partition & Acoustic Blanket Partition and Acoustic Blankets can be used in metal and timber stud partition walls as an acoustic ceiling overlay for reducing airborne sound transfer • Rhino White Sound Baffle for Acoustic Applications - 100% Polyester designed to be layer stacked above partition walls.
BATTS
BATTS
RHINO WHITE Polyester is non hazardous.
WHITE BATTS
BATTS are
are WHITE is
RHINO WHITE Polyester has been tested and certified non-flammable and complies with the requirements of IEC 60695-11-5. Certificates available from our website. Non Corrosive: RHINO WHITE polyester is pH7.8 (pH7 is neutral) Non Toxic, Non Allergenic, Non Irritant: There are no known hazards with the use or handling of RHINO WHITE polyester. Vermin: RHINO WHITE polyester is naturally resistant to insect and vermin attack.
Thermal Performance: RHINO WHITE Insulation Building Regulations: RHINO WHITE Insulation will support and
Durability: RHINO WHITE Insulation has a 50 Year Durability Warranty. RHINO WHITE thermal insulation when installed in accordance with the manufacturer's instructions will satisfy the 50 year durability criteria for minimum design life as set out in the ABCB guidance document Durability in Buildings 2006 (Section 2.4).
back to recycle, uncontaminated RHINO WHITE insulation to help keep it out of landďŹ ll. For more information on recycling RHINO WHITE contact THOR on freephone 1300 880 828.
WHITE
Partition & Acoustic Blankets
Acoustic
have
RHINO WHITE, contact THOR BUILDING PRODUCTS on 1300 880 828.
Acoustic WHITE Sound Blanket fo the installer and building occupiers. Supplied in roll form to allow fast and efficient use and minimise waste. RHINO
WRA Blanket-40-610 WRA Blanket-40-450
4
WRA Blanket-50-610 WRA Blanket-50-450 WRA Blanket-60-610 WRA Blanket-60-450 WRA Blanket-70-610 WRA Blanket-70-450 WRA Blanket-80-610 WRA Blanket-80-450 WRA Blanket-90-610 WRA Blanket-90-450
WHITE RHINO WHITE COMMERCIAL PARTITION BLANKET is supplied standard in either 11 or 14kgm3 and ranged in to match the product thickness as closely as possible to the stud depth. RHINO WHITE COMMERCIAL PARTITION labour costs. Being 100% polyester it is non toxic and completely safe for the installer and building occupiers.
WRP Blanket-50-610-11 WRP Blanket-50-450-11 WRP Blanket-75-610-11 WRP Blanket-75-450-11 WRP Blanket-50-610-14 WRP Blanket-50-450-14 WRP Blanket-75-610-14 WRP Blanket-75-450-14 WRP Blanket-90-610-14 WRP Blanket-90-450-14
performance of partition wall and ceiling systems. RHINO WHITE PERFORMANCE INFILL improves the acoustic separation by reducing noise intrusion and increasing sound privacy between spaces. HPI should be used where optimal acoustic performance is required. Manufactured from 100% polyester RHINO WHITE PERFORMANCE INFILL is completely safe for installer and building occupiers and has no known health hazards.
WRH Infill-60-610 WRH Infill-60-450 WRH Infill-90-610 WRH Infill-90-450 WRH Infill-165-610 WRH Infill-165-450
low temperatures and extended periods ofstorage in compressed packaging. Installing product at less than
WRA Blanket-60 WRA Blanket-70 WRH Infill-60 WRA Blanket-60 WRA Blanket-70 WRH Infill-60 WRA Blanket-60 WRP Blanket-90-14 WRH Infill-90 WRA Blanket-70 WRP Blanket-75-11 WRH Infill-90 WRA Blanket-80 WRP Blanket-90-14 WRH Infill-90 WRA Blanket-70 WRP Blanket-75-11 WRP Blanket-75-14 WRH Infill-165 WRP Blanket-60
Acoustic
The Green Building Council of Australia (GBCA) has developed assessment tools to contribute to points available in the various tools as set out in the table below.
helping keep it out of landďŹ ll. Please contact your THOR Account Manager for further details.
Green Star Materials credits aim to improve the environmental impacts of building products and materials. RHINO WHITE will assist in achieving the available credits in the applicable calculators. RHINO has a 50+year durability warranty, high recycled content and manufactured to
RHINO WHITE INSULATION RANGE has been independently tested and is well below the allowable
RHINO WHITE SOUND BAFFLE is a 100% polyester
RHINO WHITE SOUND BAFFLE is designed for use above new or
WHITE
RHINO WHITE SOUND BAFFLE must be installed with at least
the stack. RHINO WHITE SOUND BAFFLE can be installed to a height
WHITE SOUND BAFFLE WHITE
WHITE SOUND BAFFLE
WHITE SOUND BAFFLE
WRB Block-100-600
WHITE WHITE
WHITE has been engineered to supply a
should be installed as a layer stack above
RHINO WHITE contact THOR BUILDING
WHITE SOUND BAFFLE
by THOR BUILDING PRODUCTS
Section 4 RHINO CELL INSULATION RANGE • Rhino Cell 104 3 in 1 insulation, vapour-barrier and radiant heat barrier for use in roof, wall and floor systems • Rhino Cell 310 3 in 1 insulation, vapour-barrier and radiant heat barrier for use in roof, wall and floor systems • Rhino Shed 3 in 1 insulation, vapour-barrier and radiant heat barrier for use in shed walls / under-roof systems where anti-glare is not requested • Rhino Cell Cavity Wall 3 in 1 insulation, vapour-permeable and radiant heat barrier for use in wall systems • Rhino Cell Underfloor 3 in 1 insulation, vapour-permeable and radiant heat barrier for use in underfloor systems
Information Technology Solutions
Rhino Cell 104 AG Product Description
Product Specification
Rhino Cell 104 is a 3 in 1 insulation, vapour barrier and radiant heat barrier for use in roof, wall and floor systems.
WIDTH:
1.35m(+0.15m flap)
LENGTH:
22.25m
AREA:
30m2
The fibre-free, non-allergenic, formaldehyde free materials used in Rhino Cell provide a safe solution which is also easy to install.
THICKNESS:
4mm ± 1mm
LAMINATE 1:
Polyethylene weave Al Foil
BUBBLE COMPOSITION:
Polyethylene
LAMINATE 2:
Polyethylene weave Al Foil
Rhino Cell is strong, durable, has low flammability index (≤5) and is both rodent and insect resistant.
Available in Blue Antiglare surface finish. Product Code
Description
Thickness (mm)
R-Value (m2 K/W)
Dimensions (m)
m2 per pack
RC-104 AG
Rhino Cell Antiglare
4mm
R-0.10
1.35 (+0.15m flap) x 22.25
30
(pack 0.32 dia. x 1.5) (pack mass 11.5kg)
Finished Product Performance
Compliance to AS 4859.1 &AS4200.1 TEST
Manufacturing Process: :
Proudly Manufactured by
Thor Building Products P/L
1300 880 828
(07) 3219 6833 SALES@THORBUILDING.COM.AU 293 EARNSHAW ROAD PO BOX 14 NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
DESCRIPTION
PARAMETER
ASTM E - 408
Emissivity
AS/NZS 4859.1 App – I AS/NZS 4859.1 App – H ASTM 1530.2
Surface Corrosion Corrosiveness Flammability
ASTM 1530.3
Early Fire Hazard
AS/NZS 3837 AS 1301.448 TAPPI T470 AS 2001.2.19 AS 4201.1 AS 4201.2 AS 4201.3 AS 4201.4 AS 4201.6 ASTM E-96
Cone Calorimeter Duty Rating, Tensile Strength Duty Rating, Edge Tear Resistance Bursting Strength Resistance to Dry Delamination Resistance to Wet Delamination Shrinkage Water Barrier Absorbency Vapour Transmission
reflective face = 0.03 ± 0.01 antiglare face = 0.05 ± 0.01 Pass Pass Low (index ≤ 5) Ignitability index - N/A Spread of Flame - ≤ 9 Heat Evolved Ind. - N/A Smoke developed Ind. - ≤ 5 BCA Classification 1 EXTRA HEAVY EXTRA HEAVY Stated Pass Pass ≤ 5% High Unclassified Medium
Thermal Performance Application
Heat Flow In
Heat Flow Out
Warehouse metal roof retrofit, fully sealed
R-3.0
R-0.8
Floor, suspended timber enclosed sub floor
R-3.1
R-1.6
Commercial office metal roof, with ceiling
R-3.5
R-1.2
Residential Pitched Metal roof 22°, ventilated
R-2.5
R-1.1
Brick veneer wall
R-1.9
R-2.1
R values shown are Total R values for the building element calculated by a chartered professional engineer and verified by a recognised laboratory. Total R values of the above systems for winter and summer conditions have been determined in accordance with the requirements of AS/NZS4859.1:2002 Amdt 1 (2006), App K. The contribution of this product total R-value depends on installation and environmental conditions. The R-value will be reduced in the event of the accumulation of dust on upward facing surfaces and in those cavities that are ventilated.
M a n u f a c tInformation u r e d b y Technology Solutions
Rhino Cell 310 AG Product Description Rhino Cell 310 Thermal Break is a 3 in 1 insulation, vapour barrier and radiant heat barrier for use in roof, wall and floor systems.
Product Specification WIDTH:
The fibre-free, non-allergenic, formaldehyde free materials used in Rhino Cell provide a safe solution which is also easy to install. Rhino Cell is strong, durable, has low flammability index (≤5) and achieves a Thermal Break of R-0.2.
1.35m (+0.15m Flap)
LENGTH:
22.25m
AREA:
30m2 coverage
THICKNESS:
11mm
LAMINATE 1:
Polyethylene weave Al Foil
BUBBLE COMPOSITION:
Polyethylene
LAMINATE 2:
Polyethylene weave Al Foil
Available in Blue Antiglare surface finish. UNIQUE 150MM FLAP ELIMINATES NEED FOR OVERLAP SAVING UP TO 10% FLAP FOR ADDED COVERAGE
Product Code
Description
Thickness (mm)
R-Value (m2 K/W)
Dimensions (m)
RC-310 AG
Rhino Cell Antiglare
11mm
R-0.20
(pack 0.49 dia. x 1.5) (pack mass 12.5kg)
Proudly Manufactured by
Thor Building Products P/L
1300 880 828
(07) 3219 6833 SALES@THORBUILDING.COM.AU 293 EARNSHAW ROAD PO BOX 14 NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
30
Finished Product Performance DESCRIPTION
ASTM E - 408
:
1.35 x 22.25
Compliance to AS 4859.1 &AS4200.1 TEST
Manufacturing Process:
m2 per pack
Emissivity
AS/NZS 4859.1 App - I AS/NZS 4859.1 App - H ASTM 1530.2
Surface Corrosion Corrosiveness Flammability
ASTM 1530.3
Early Fire Hazard
AS/NZS 3837 AS 1301.448 TAPPI T470 AS 2001.2.19 AS 4201.1 AS 4201.2 AS 4201.3 AS 4201.4 AS 4201.6 ASTM E-96
Cone Calorimeter Duty Rating, Tensile Strength Duty Rating, Edge Tear Resistance Bursting Strength Resistance to Dry Delamination Resistance to Wet Delamination Shrinkage Water Barrier Absorbency Vapour Transmission
PARAMETER reflective face = 0.03 ± 0.01 antiglare face = 0.05 ± 0.01 Pass Pass Low (index≤ 5) Ignitability index - N/A Spread of Flame - ≤ 9 Heat Evolved Ind. - N/A Smoke developed Ind. - ≤ 5 BCA Classification 1 EXTRA HEAVY EXTRA HEAVY Stated Pass Pass ≤ 5% High Unclassified Medium
Thermal Performance Application
Heat Flow In
Heat Flow Out
Warehouse metal roof with ceiling 300mm, no vent
R-3.6
R-1.3
Residential metal pitched roof 22° steel frame, ventilated
R-2.6
R-1.2
Warehouse metal roof, no ceiling fully sealed
R-2.1
R-1.0
R values shown are Total R values for the building element calculated by a chartered professional engineer and verified by a recognised laboratory. Total R values of the above systems for winter and summer conditions have been determined in accordance with the requirements of AS/NZS4859.1:2002 Amdt 1 (2006), App K. The contribution of this product total R-value depends on installation and environmental conditions. The R-value will be reduced in the event of the accumulation of dust on upward facing surfaces and in those cavities that are ventilated.
RHINO SHEDInformation Technology Solutions
Product Description Product Specification
Rhino Cell 310 Thermal Break is a 3 in 1 insulation, vapour barrier and radiant heat barrier for use in roof, wall and floor systems. Rhino Shed is a 3 in 1 insulation, vapourbarrier and radiant heat barrier for use in shed walls and shed under-roof systems where antiglare is not requested. The fibre-free, non-allergenic, formaldehyde free materials used in Rhino Shed provides a safe solution which is also easy to install.
WIDTH:
1.350m
LENGTH:
22.25m
AREA:
30m2
THICKNESS:
4mm ± 1mm
LAMINATE 1:
Polyethylene weave Al Foil
BUBBLE COMPOSITION:
Polyethylene
LAMINATE 2:
Polyethylene weave Al Foil
Product Code
Description
Thickness (mm)
R-Value (m2 K/W)
RSHD
Rhino Shed
4mm
R-0.10
Dimensions (m)
m2 per pack
1.35 x 22.25
30
(pack 0.32 dia. x 1.35) (pack mass 11.5kg)
Finished Product Performance
Compliance to AS 4859.1 &AS4200.1 TEST
Manufacturing Process: :
Proudly Manufactured by
Thor Building Products P/L
1300 880 828
(07) 3219 6833 SALES@THORBUILDING.COM.AU 293 EARNSHAW ROAD PO BOX 14 NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
DESCRIPTION
PARAMETER
ASTM E - 408 AS/NZS 4859.1 App – I AS/NZS 4859.1 App – H ASTM 1530.2
Emissivity Surface Corrosion Corrosiveness Flammability
ASTM 1530.3
Early Fire Hazard
AS/NZS 3837 AS 1301.448 TAPPI T470 AS 2001.2.19 AS 4201.1 AS 4201.2 AS 4201.3 AS 4201.4 AS 4201.6 ASTM E-96
Cone Calorimeter Duty Rating, Tensile Strength Duty Rating, Edge Tear Resistance Bursting Strength Resistance to Dry Delamination Resistance to Wet Delamination Shrinkage Water Barrier Absorbency Vapour Transmission
reflective face = 0.03 ± 0.01 Pass Pass Low (index ≤ 5) Ignitability index - N/A Spread of Flame - ≤ 9 Heat Evolved Ind. - N/A Smoke developed Ind. - ≤ 5 BCA Classification 1 EXTRA HEAVY EXTRA HEAVY Stated Pass Pass ≤ 5% High Unclassified Medium
Thermal Performance Application
Heat Flow In
Heat Flow Out
Shed metal roof retrofit, fully sealed
R-3.0
R-0.8
Shed metal roof, with ceiling
R-3.5
R-1.2
Shed pitched metal roof 22°, ventilated
R-2.5
R-1.1
Shed metal clad wall, 100mm air gap
R-1.1
R-1.2
R values shown are Total R values for the building element calculated by a chartered professional engineer and verified by a recognised laboratory. Total R values of the above systems for winter and summer conditions have been determined in accordance with the requirements of AS/NZS4859.1:2002 Amdt 1 (2006), App K. The contribution of this product total R-value depends on installation and environmental conditions. The R-value will be reduced in the event of the accumulation of dust on upward facing surfaces and in those cavities that are ventilated.
a n u f a c tInformation u r e d b y Technology Solutions CavityMWall
Product Description Rhino Cell Cavity Wall is a 3 in 1 insulation, vapour-permeable and radiant heat barrier for use in wall systems. The fibre-free, non-allergenic, formaldehyde free materials used in Rhino Cell Cavity Wall provide a safe solution which is also easy to install. Rhino Cell Cavity Wall is strong, durable, has low flammability index (≤5) and is both rodent and insect resistant. Available in Blue Antiglare surface finish.
Product Code
RC-CW AG
Product specification WIDTH:
1.35m
LENGTH:
22.25m
AREA:
30m2
THICKNESS:
4mm ± 1mm
LAMINATE 1:
Polyethylene weave Al Foil
BUBBLE COMPOSITION:
Polyethylene
LAMINATE 2:
Polyethylene weave Al Foil
Manufacturing Process:
Description
Thickness (mm)
R-Value (m2 K/W)
4mm
R-0.10
Rhino Cell Cavity Wall
32 Lysaght Street Acacia Ridge QLD 4110 PH
1300 880 828
sales@thorbuilding.com.au www.thorbuilding.com.au
m2 per pack
1.35 x 22.25
30
(pack 0.32 dia. x 1.35) (pack mass 11.5kg)
Finished Product Performance Compliance to AS 4859.1 &AS4200.1 TEST
DESCRIPTION
ASTM E - 408
Emissivity
AS/NZS 4859.1 App – I AS/NZS 4859.1 App – H ASTM 1530.2
Surface Corrosion Corrosiveness Flammability
ASTM 1530.3
Early Fire Hazard
AS/NZS 3837 AS 1301.448 TAPPI T470 AS 2001.2.19 AS 4201.1 AS 4201.2 AS 4201.3 AS 4201.4 AS 4201.6 ASTM E-96
Cone Calorimeter Duty Rating, Tensile Strength Duty Rating, Edge Tear Resistance Bursting Strength Resistance to Dry Delamination Resistance to Wet Delamination Shrinkage Water Barrier Absorbency Vapour Transmission
PARAMETER reflective face = 0.03 ± 0.01 antiglare face = 0.05 ± 0.01 Pass Pass Low (index ≤ 5) Ignitability index - N/A Spread of Flame - ≤ 9 Heat Evolved Ind. - N/A Smoke developed Ind. - ≤ 5 BCA Classification 1 EXTRA HEAVY EXTRA HEAVY Stated Pass Pass ≤ 5% Low Unclassified Medium
Thermal Performance Application
Thor Building Products P/L
Dimensions (m)
Heat Flow In
Heat Flow Out
Warehouse metal roof retrofit, fully sealed
R-3.0
R-0.8
Floor, suspended timber enclosed sub floor
R-3.1
R-1.6
Commercial office metal roof, with ceiling
R-3.5
R-1.2
Residential Pitched Metal roof 22°, ventilated
R-2.5
R-1.1
Brick veneer wall
R-1.9
R-2.1
R values shown are Total R values for the building element calculated by a chartered professional engineer and verified by a recognised laboratory. Total R values of the above systems for winter and summer conditions have been determined in accordance with the requirements of AS/NZS4859.1:2002 Amdt 1 (2006), App K. The contribution of this product total R-value depends on installation and environmental conditions. The R-value will be reduced in the event of the accumulation of dust on upward facing surfaces and in those cavities that are ventilated.
Information Technology Solutions Rhino Cell UNDERFLOOR
Product Description Product Specification
Rhino Underfloor is a 3 in 1 insulation, vapour-permeable and radiant heat barrier for use in underfloor systems.
WIDTH:
The fibre-free, non-allergenic, formaldehyde free materials used in Rhino Underfloor provide a safe solution which is also easy to install. Rhino Underfloor is strong, durable, has low flammability index (≤5) and is both rodent and insect resistant.
Product Code
Available in Blue Antiglare surface finish.
RC-UF AG
0.50m
LENGTH:
30m
AREA:
45m 2
THICKNESS:
4mm ± 1mm
LAMINATE 1:
Polyethylene weave Al Foil
BUBBLE COMPOSITION:
Polyethylene
LAMINATE 2:
Polyethylene weave Al Foil
Description
Thickness (mm)
R-Value (m2 K/W)
Rhino Underfloor
4mm
R-0.10
Dimensions (m)
0.50 x 30
(pack 0.50 dia. x 1.50) (pack mass 18.5g)
m2 per pack
45
3 rolls per pack
Finished Product Performance
Compliance to AS 4859.1 &AS4200.1 TEST
Manufacturing Process: :
Proudly Manufactured by
Thor Building Products P/L
1300 880 828
(07) 3219 6833 SALES@THORBUILDING.COM.AU 293 EARNSHAW ROAD PO BOX 14 NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
DESCRIPTION
PARAMETER
ASTM E - 408
Emissivity
AS/NZS 4859.1 App – I AS/NZS 4859.1 App – H ASTM 1530.2
Surface Corrosion Corrosiveness Flammability
ASTM 1530.3
Early Fire Hazard
AS/NZS 3837 AS 1301.448 TAPPI T470 AS 2001.2.19 AS 4201.1 AS 4201.2 AS 4201.3 AS 4201.4 AS 4201.6 ASTM E-96
Cone Calorimeter Duty Rating, Tensile Strength Duty Rating, Edge Tear Resistance Bursting Strength Resistance to Dry Delamination Resistance to Wet Delamination Shrinkage Water Barrier Absorbency Vapour Transmission
reflective face = 0.03 ± 0.01 antiglare face = 0.05 ± 0.01 Pass Pass Low (index ≤ 5) Ignitability index - N/A Spread of Flame - ≤ 9 Heat Evolved Ind. - N/A Smoke developed Ind. - ≤ 5 BCA Classification 1 EXTRA HEAVY EXTRA HEAVY Stated Pass Pass ≤ 5% Low Unclassified Medium
Thermal Performance Application
Heat Flow In
Heat Flow Out
Warehouse metal roof retrofit, fully sealed
R-3.0
R-0.8
Floor, suspended timber enclosed sub floor
R-3.1
R-1.6
Commercial office metal roof, with ceiling
R-3.5
R-1.2
Residential Pitched Metal roof 22°, ventilated
R-2.5
R-1.1
Brick veneer wall
R-1.9
R-2.1
R values shown are Total R values for the building element calculated by a chartered professional engineer and verified by a recognised laboratory. Total R values of the above systems for winter and summer conditions have been determined in accordance with the requirements of AS/NZS4859.1:2002 Amdt 1 (2006), App K. The contribution of this product total R-value depends on installation and environmental conditions. The R-value will be reduced in the event of the accumulation of dust on upward facing surfaces and in those cavities that are ventilated.
by THOR BUILDING PRODUCTS
Section 5 RHINO FOAM INSULATION RANGE • Rhino Foam 40 Fire retardant foam core laminated to two layers of high performance reflective woven aluminium foil • Rhino Foam 75 Fire retardant foam core laminated to two layers of high performance reflective woven aluminium foil • Rhino Insulsteel 65 Fire retardant foam core laminated to two layers of high performance reflective woven aluminium foil
RHINO FOAM 40
40
Thermal Break
Product Description Rhino Foam 40 AG Thermal Break combines an inner layer of fire retardant foam core laminated to two layers of high performance reflective woven aluminium foil. This proudly Australian made insulation features an anti-glare coating on one side for safe, easy installation as well as advanced thermal performance reflecting up to 97% of radiant heat flow. Our Thermal break product provides an energy efficient solution for roof and wall applications in accordance with the BCA and is proudly Australian made. Unique: 1500mm flap eliminates need for overlap, saving up to 10%
Product specification Product Code WIDTH:
1350mm (+0.15m Flap)
LENGTH:
22.25m
AREA:
30m
THICKNESS:
4.0 ± 1mm
RF-40 AG
Description
Thickness (mm)
R-Value (m 2 K/W)
Dimensions (m)
4.0mm
R-0.10
1350mm x 22.25m (+0.15mFlap)
Rhino Foam 40 AG
m 2 per pack
30
ANTIGLARE REFLECTIVITY: 95% SILVER REFLECTIVITY: 97%
Finished Product Performance SAFETY INSTRUCTIONS No personal protective equipment is required, however, it is recommended that UV protective sunglasses be worn when installing outside. This product is non-hazardous. When installing ensure that all electrical cabling, fittings, and wiring are in a safe condition and there is no potential for contact with live wiring or down-lights. Ensure a minimum 50mm clearance from light fittings (check for safe distance with lighting supplier) and ensure 50mm clearance around hot flues. Plastic fixings should be used where any electrical componentry is in close vicinity of the installation materials. Do not use any metal fixings if working in close vicinity of electrical wiring.
Manufacturing Process:
Compliance to AS 4859.1 &AS4200.1 TEST
DESCRIPTION
PARAMETER
ASTM E - 408
Emissivity
Silver 0.03 / Anti-Glare 0.05
AS/NZS 4859.1 App – I
Surface Corrosion
Pass
AS/NZS 4859.1 App – H
Corrosiveness
Pass
ASTM 1530.2
Flammability
Low (index ≤ 5)
ASTM 1530.3
Early Fire Hazard
AS/NZS 3837
Cone Calorimeter
AS 1301.448 TAPPI T470 AS 2001.2.19 AS 4201.1 AS 4201.2 AS 4201.3 AS 4201.4 AS 4201.6 ASTM E-96
Duty Rating, Tensile Strength Duty Rating, Edge Tear Resistance Bursting Strength Resistance to Dry Delamination Resistance to Wet Delamination Shrinkage Water Barrier Absorbency Vapour Transmission
293 Earnshaw Road Northgate QLD 4013
HeatFlow Flow In Heat In
Pitched Pitched Metal MetalRoof, Roof,flat flatceiling ceiling(Fully-Sealed (Fully-SealedAirspace Airspacebetween betweenMetal MetalRoof Roof&&Oasis Oasis7.0 7.0Thermal ThermalBreak) Break)
2.8
2.8
Pitched Metal Metal Roof Roof (22° (22° W Warehouse) arehouse) (Fully-Sealed (Fully-SealedAirspace Airspace between between Metal Metal Roof Roof && Oasis Oasis 7.0 7.0 Thermal Thermal Break) Break) Pitched
1.7
1.7
3.9
3.9
2.1
2.1
FlatMetal MetalRoof Roof (Warehouse) (Fully-Sealed Airspace between Metal Roof 7.0 & Oasis 7.0Break) Thermal Break) Flat (Warehouse) (Fully-Sealed Airspace between Metal Roof & Oasis Thermal MetalClad CladW Wall all Metal
sales@thorbuilding.com.au www.thorbuilding.com.au
Brick Veneer Wall
1300 880 828
EXTRA HEAVY DUTY EXTRA HEAVY DUTY Stated Pass Pass ≤ 5% High High Medium
Application Application
Metal Clad Wall & Plasterboard Lining Metal Clad Wall & Plasterboard Lining Double Brick Wall Doubel Brick Wall Brick Veneer Wall
PH
N/A
Thermal Performance
Flat FlatMetal MetalRoof, Roof,suspended suspendedceiling ceiling(Fully-Sealed (Fully-SealedAirspace Airspacebetween betweenMetal MetalRoof Roof&&Oasis Oasis7.0 7.0Thermal ThermalBreak Break)
Thor Building Products P/L
0/0/0/1
1.1
1.1
1.81.8 2.12.1 2 2
Heat Flow O Out Heat Flow
1.3 1.3 1
1
1.4 1.4 1 1.1
1 1.1
1.71.7 2.12.1 2 2
RHINO FOAM 75
75
Thermal Break
Product Description Rhino Foam 75 AG Thermal Break combines an inner layer of fire retardant foam core laminated to two layers of high performance reflective woven aluminium foil. This proudly Australian made insulation features an anti-glare coating on one side for safe, easy installation as well as advanced thermal performance reflecting up to 97% of radiant heat flow. Our Thermal break product provides an energy efficient solution for roof and wall applications in accordance with the BCA and is proudly Australian made. Unique: 1500mm flap eliminates need for overlap, saving up to 10%
Product specification Product Code WIDTH:
1350mm (+0.15m Flap)
LENGTH:
22.25m
AREA:
30m
THICKNESS:
7.5 ± 1mm
RF-75 AG
Description
Thickness (mm)
R-Value (m 2 K/W)
Dimensions (m)
m 2 per pack
7.5mm
R-0.20
1350mm x 22.25m (+0.15m Flap)
30
Rhino Foam 75 AG
ANTIGLARE REFLECTIVITY: 95% SILVER REFLECTIVITY: 97%
Finished Product Performance SAFETY INSTRUCTIONS No personal protective equipment is required, however, it is recommended that UV protective sunglasses be worn when installing outside. This product is non-hazardous. When installing ensure that all electrical cabling, fittings, and wiring are in a safe condition and there is no potential for contact with live wiring or down-lights. Ensure a minimum 50mm clearance from light fittings (check for safe distance with lighting supplier) and ensure 50mm clearance around hot flues. Plastic fixings should be used where any electrical componentry is in close vicinity of the installation materials. Do not use any metal fixings if working in close vicinity of electrical wiring.
Manufacturing Process:
Compliance to AS 4859.1 &AS4200.1 TEST
DESCRIPTION
PARAMETER
ASTM E - 408
Emissivity
Silver 0.03 / Anti-Glare 0.05
AS/NZS 4859.1 App – I
Surface Corrosion
Pass
AS/NZS 4859.1 App – H
Corrosiveness
Pass
ASTM 1530.2
Flammability
Low (index ≤ 5)
ASTM 1530.3
Early Fire Hazard
AS/NZS 3837
Cone Calorimeter
AS 1301.448 TAPPI T470 AS 2001.2.19 AS 4201.1 AS 4201.2 AS 4201.3 AS 4201.4 AS 4201.6 ASTM E-96
Duty Rating, Tensile Strength Duty Rating, Edge Tear Resistance Bursting Strength Resistance to Dry Delamination Resistance to Wet Delamination Shrinkage Water Barrier Absorbency Vapour Transmission
293 Earnshaw Road Northgate QLD 4013
HeatFlow Flow In Heat In
Pitched Pitched Metal MetalRoof, Roof,flat flatceiling ceiling(Fully-Sealed (Fully-SealedAirspace Airspacebetween betweenMetal MetalRoof Roof&&Oasis Oasis7.0 7.0Thermal ThermalBreak) Break)
2.8
2.8
Pitched Metal Metal Roof Roof (22° (22° W Warehouse) arehouse) (Fully-Sealed (Fully-SealedAirspace Airspace between between Metal Metal Roof Roof && Oasis Oasis 7.0 7.0 Thermal Thermal Break) Break) Pitched
1.7
1.7
3.9
3.9
2.1
2.1
FlatMetal MetalRoof Roof (Warehouse) (Fully-Sealed Airspace between Metal Roof 7.0 & Oasis 7.0Break) Thermal Break) Flat (Warehouse) (Fully-Sealed Airspace between Metal Roof & Oasis Thermal MetalClad CladW Wall all Metal
sales@thorbuilding.com.au www.thorbuilding.com.au
Brick Veneer Wall
1300 880 828
EXTRA HEAVY DUTY EXTRA HEAVY DUTY Stated Pass Pass ≤ 5% High Unclassified Medium
Application Application
Metal Clad Wall & Plasterboard Lining Metal Clad Wall & Plasterboard Lining Double Brick Wall Doubel Brick Wall Brick Veneer Wall
PH
N/A
Thermal Performance
Flat FlatMetal MetalRoof, Roof,suspended suspendedceiling ceiling(Fully-Sealed (Fully-SealedAirspace Airspacebetween betweenMetal MetalRoof Roof&&Oasis Oasis7.0 7.0Thermal ThermalBreak Break)
Thor Building Products P/L
0/0/0/1
1.1
1.1
1.81.8 2.12.1 2 2
Heat Flow O Out Heat Flow
1.3 1.3 1
1
1.4 1.4 1 1.1
1 1.1
1.71.7 2.12.1 2 2
Information Technology Solutions
Rhino Insulsteel 65 Rhino “Insulsteel 65.” “Insulsteel 65” has a thermal break to comply with the BCA standards* and the National Construction Code 2011, which requires an R0.20 thermal break for steel framed constructions to reduce thermal bridging and conductivity between the building products.
A chemically cross-linked polyethylene foam structure, Insulsteel 65 is laminated on both sides, with highly reflective foil, with one side antiglare, making this product ideal as an Insulation as well as a Vapour Barrier and a Thermal Break. *BCA Vol 1. Section J1.3(d) J1.5(b) (c) Vol 2.3.12.1.2(c) Roof 3.12.1.4 (b) Wall. Rhino Insulsteel can also be used in other forms of construction such as tilt slab concrete walls, (with breather holes) brick veneer walls, and timber roofs. (Please consult our user and installation guide for further details).
Product Testing
Product Information
Test
Test Standard
Result
Corrosion Resistance
AS/NZS 4859.1 Appen 1
Pass
Thermal Resistance
AS/NZS 4859.1 ISO8302:1991
R0.216
Cone Calorimeter
AS/NZS 3837
Group 1
Product Thickness
6.5mm (min)
Flammabilty
AS 1530.2
Low Index <5
Roll Size
22.25m x 1.350mm (30m2 )
Ignitability Flame Spread Heat Release Smoke Release Emittance
AS 1530.3
0/0/0/1
ASTM-E408
Roll Weight
12kg
Reflective E0.03 Anti-glare E0.08
Roll Diameter
460mm
Vapour Transmission
ASTM E96-2005
Medium
Reflectance Antiglare
92%
Dry Delamination
AS/NZS 4201.1-1994
Pass
Reflective Side
97%
Wet Delamination
AS/NZS 4859.1-2002 App.1
Pass
Shrinkage
AS/NZS 4201.3-1994
Complies – 0.3%
Duty
AS 4200.1-1994 Table1. Complies
Extra Heavy Duty
Max Span
Manufacturing Process: :
Rhino Insulsteel products carry a 10 year warranty on Commercial applications and a 15 year warranty on Domestic applications against Delamination and Oxidation. ** subject to Thermacon Insulsteel Pty Ltd standard warranty guidelines (available upon request). **
Proudly Manufactured by
Thor Building Products P/L
1300 880 828
(07) 3219 6833 SALES@THORBUILDING.COM.AU 293 EARNSHAW ROAD PO BOX 14 NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
Thermal Performance^ Construction Type
Heat Flow In
Heat Flow Out
Steel Stud Frames Wall Insulsteel 65
R1.68
R1.88
Brick Veneer Wall Insulsteel 65
R1.85
R2.11
R1.9
R2.1
Commercial Metal Roof Suspended Ceiling Insulsteel 65 Tilt Slab Concrete Office Wall Insulsteel 65
For other Thermal Performance figures please consult our Technical Data Sheet. ^ The R-Values shown were prepared and certified by James M. Fricker MIEAust. CPEng. Consultant engineer in insulation to the BCA, the NCC 2011, and the insulation industry. These values are based upon product in an in service condition, and are in accordance with AS/NZS 4859.1:2002. Total R Values are based on product in-service conditions in accordance with AS/NZS 4859.1:2002/Amdt 1 (Dec 2006) including the alteration of insulation material R for temperature and derations of reflective foil emittances due to dust as noted. Where a cavity is sealed, it is assumed there is no dust and n=hence emittance is not derated.
by THOR BUILDING PRODUCTS
Section 6 RHINO WRAP REFLECTIVE FOIL RANGE • Rhino Wrap (RP-51 & RP-51B) Laminate of aluminium foil and polywoven fabric • Rhino Foil (RF-51 & RF-51B) Lighter wrap with improved bond strength • Rhino Metal Roofing (RP-51MR) Laminate of aluminium foil and polywoven fabric • Rhino Roofing (RP-61) Laminate of aluminium foil and polywoven fabric • Rhino High Performance Roofing (RP-91 HP-15) Extra heavy duty laminate of aluminium foil and polywoven fabric • Rhino Multipurpose (RP-51WR) Laminate of aluminium foil and polywoven fabric • Rhino Tile & Metal Roofing (RP-51TM) Laminate of aluminium foil and polywoven fabric • Rhino Facing Foil Rhino Blanket Facing reflective foil face faces down toward the air space under the roof and prevents airborne moisture from reaching the surface of the roof cladding, made with a high strength polywoven fabric facing which is applied to a glasswool blanket.
Information Technology Solutions RHINO FOIL RF-51 & RF-51B
PRODUCT INFORMATION Rhino Foil Products are specifically manufactured to the highest industry standards. WALL INSTALLATION: Up to R1.1 may be added to the wall system when Rhino Foil RF-51 & RF-51B is installed as wall cladding behind brick veneer/timber cladding. Our specialised manufacturing process bonds together Aluminium Foil to a high strength reinforcing Polymer Mesh using a flame retardant adhesive. Our Reinforcing Polymer Mesh is purposely-treated blue in colour to reduce reflective glare problems when Rhino Foil is installed.
LIGHT WEIGHT SUPER STRENGTH
HOUSE RF-51 RF-51B
Satisfy BCA specifications and requirements for Reflective Foil Laminates. Complies with the specifications and requirements of AS/NZS 4200.1 for "Pliable Building Membranes" which is a manual recognised by the BCA Part 3.5 Roof and Cladding. Low Flammability Index in accordance with AS 1530.2 <5 Satisfy BCA Part 3.7.1 Fire Hazard Properties. Satisfy Health & Safety Regulations.
RHINO FOIL USAGE In all applications: • External cladding should be installed A.S.A.P • No contact is to be made with wet concrete or mortar • Store in dry area, weather proofed only after installation • Shrinkage of up to 2% can be expected In reflective foil laminate applications: • Use only in accordance with AS/NZS 4200.2 for the "Installation Requirements for Pliable Building Membranes" • Minimum of 20mm air space is recommended adjacent to reflective foil face to achieve Maximum insulation values
WRAP
THE ULTIMATE PROTECTION Proudly Manufactured by
Thor Building Products P/L
1300 880 828
(07) 3219 6833 SALES@THORBUILDING.COM.AU 293 EARNSHAW ROAD PO BOX 14 NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
Recommended Applications and Properties Residential Wall Insulation Commercial Wall Insulation Duty Vapour barrier Emittance Water barrier Flammability Index < 5 Tensile Strength Machine Direction (kN/M) Tensile Strength Lateral Direction (kN/M) Edge Tear Resistance Machine Direction (N) Edge Tear Resistance Lateral Direction (N) Water Vapour Transmission Rate (Ng/Ns) Emmittance of Reflective Face Availability
Width 1350MM Width 1350MM
Length 30M Length 60M
Area 40.5M 2 Area 81M 2
RF-51
RF-51B
Medium
Medium
High
Low
Reflective Reflective High
Unclassified
<5
<5
min 9.5
min 9.5
min 6.0
min 6.0
min 65
min 65
min 65
min 65
max 2
min 140
max 0.05
max 0.05
WRAP RP-SHEET 51 & RP-51B PRODUCT DATAPRODUCT SHEET RHINODATA RHINO WRAP RP-51 & RP-51B
HEAVY DUTY
WALL WRAP
RP-51 RP-51B
the ultimate p rot ect i o n
Satisfy BCA specifications and requirements for Reflective Foil Laminates Complies with the specifications and requirements of AS/NZS 4200.1 for Satisfy BCA specifications and requirements Laminates "Pliable Building Membranes" whichfor is Reflective a manualFoil recognised by the CompliesBCA withPart the3.5 specifications and requirements of AS/NZS 4200.1 for "Pliable Building Roof and Cladding Membranes" which is a manual by thewith BCAAS Part 3.5 Roof Low Flammability Indexrecognised in accordance 1530.2 <5and Cladding Low Flammability accordance withProperties AS 1530.2 <5 Satisfy BCAIndex Part in 3.7.1 Fire Hazard Satisfy BCA PartHealth 3.7.1 Fire HazardRegulations Properties Satisfy & Safety Satisfy Health & Safety Regulations
Product Information
PRODUCT INFORMATION WALL INSTALLATION: Up to R1.1 may be added to the wall
Rhino Wrap Products are specifically manufactured to the highest industry standards.
system when Wall Wrap is installed as wall Rhino Wrap Products are specifically manufactured toRhino the highest industry standards. cladding behind brick veneer/timber cladding. Our specialised manufacturing process bonds together WALL INSTALLATION: Up to R1.1 may be added to the wall system when Rhino Wrap RP-51 & Aluminium Foil to a high strength reinforcing Polymer RP-51B is installed as wallngcladding behind brick veneer/timber cladding. Our specialised h Mesh using a flame retardant adhesive. Our c es r manufacturing process together Aluminium Foil to a high strength reinforcing Polymer Mesh m n fo rbonds Reinforcing Polymer Mesh is purposely-treated blue in R eyi me using a flame retardant adhesive. Our Reinforcing Polymer Mesh is purposely-treated blue in colour po colour to reduce reflective glare problems to reduce reflective glare problems when Rhino Wrap is installed. when Rhino Wrap is installed. Aluminium foil
RhinoRhino WRAP USAGE Wrap Usage
1300 880 828 ( 07) 3246 2200 sales@thorbuilding.com.au 293 EARNSHAW ROAD PO BOX 14 NORTHGATE QLD 4013 www.thorbuilding.com.au
by THOR BUILDING PRODUCTS Totally Australian owned manufactured in Australia from local & imported components
RHINO ROOFING • RP-61 (HD)(EHD) RP-91-HP • RP-81 (EHD)
iles
r
Roof Batten
te Raf
Anti-Ponding Board Insulation
ter
Raf
Width 1350MM Length M Resistance Area 40.5 M 2 Direction(N) Edge30 Tear Lateral Width 1350MM Length 60vapour M Area 81M 2 Rate (Ng/Ns) Water Transmission 2 Width 1500MM Length 30M Area 45M Emittance of Reflective Face Width 1500MM Length 60M Area 90M 2 Availability
• RP-51 Wall Wrap
RP-51 WALL WRAP • RP-51B Breather RP-51B Breather
Flooring Bearer
Bottom Plate
Footing
RP-51B
Residential Wall Insulation Recommended Applications Applications Recommended Applications Commercial Wall Insulation and Properties Heavy Duty Heavy High Vapour barrier Residential Wall Insulation Emittance Reflective Commercial Wall Insulation High Water barrier Duty <5 Flammability Index < 5 VapourDirection barrier min 12.5 Tensile Strength Machine (kN/M) Emittance min 7.5 Tensile Strength Lateral Direction (kN/M) WaMachine ter barrier Direction (N) min 80 Edge Tear Resistance F l a m m a b i l i t y I n d e x < 5 min 80 Edge Tear Resistance Lateral Direction (N) max 2 Water Vapour Transmission RateMachine (Ng/Ns) Direction (kN/m) Tensile Strength Emmittance of Reflective Face max 0.05 Tensile Strength Lateral Direction (kN/m) Availability Edge Tear Resistance Machine Direction (N)
Ceiling Joint
Floor Joint
• Minimum of 20mm air space is recommended adjacent to reflective foil face to achieve Maximum insulation values Recommended Applications and Properties RP-51
Under Battens (where required)
Roof T
Timber Studs
In all applications: In all applications: • External cladding should be installed A.S.A.P • External cladding should be installed A.S.A.P • No contact is to be made with wet concrete or mortar is to be madeonly withafter installation • Store •inNo drycontact area, weather proofed wetofconcrete mortar • Shrinkage up to 2% or can be expected • Store in dry area, weather proofed only after installation In reflective foil laminate applications: • Use only in accordance AS/NZS 4200.2 for the • Shrinkage of upwith to 2% can be expected "Installation Requirements for Pliable Building Membranes" In reflective applications:adjacent to • Minimum of 20mmfoil air laminate space is recommended reflective foilonly faceintoaccordance achieve Maximum insulation values • Use with AS/NZS 4200.2 for the "Installation Requirements for Pliable Building Membranes"
Low RP-51
RP-51B
Reflective Unclassified
< 5 Heavy min 12.5High Reflective min 7.5
Heavy Low Reflective
min 80 High
Unclassified
min 80 <5
<5
min 140 min 12.5
min 12.5
max 0.05 min 7.5
min 7.5
min 80
min 80
min 80 max 2
min 140
max 0.05
•Width 1350mm...Length 30 metres...Area 40.5m2 •Width 1350mm...Length 60 metres...Area 81m2
•Width 1500mm ........Length 60 metres............Area 90m2
min 80
max 0.05
Information Technology Solutions RP-51MR Metal Roofing
PRODUCT INFORMATION Rhino Roofing Products are specifically manufactured to the highest industry standards. ROOF INSTALLATION - Up to R1.3 may be added to insulation system when Rhino RP-51MR is installed. Our specialised manufacturing process bonds together Aluminium Foil to a high strength reinforcing Polymer Mesh using a flame retardant adhesive. Our Reinforcing Polymer Mesh is purposely treated blue in colour to reduce reflective glare problems when installing Roofing Products.
RHINO M E TA L ROOFING RP-51MR
Membranes" which is a manual recognised by the BCA Part 3.5 Roof and Cladding Low Flammability Index in accordance with AS 1530.2 < 5 Satisfy BCA Part 3.7.1 Fire Hazard Properties Satisfy Health and Safety Regulations
RHINO METAL ROOFING USAGE • RP- 51MR Metal Roofing
In all applications:
• • • •
External cladding should be installed A.S.A.P No contact is to be made with wet concrete or mortar Store in dry area, weather proofed only after installation Shrinkage of up to 2% can be expected
•
Use only in accordance with AS/NZS 4200. 2 for the "Installation Requirements for Pliable Building Membranes" Minimum of 20MM air space is recommended adjacent to
• • •
• RP-51 Wall Wrap • RP-51B Breather
40MM sag between trusses is recommended when using Rhino RP-51MR For use in enclosed structures NOTE: Use in cold temperature climates (daytime < 5°C) requires roof to be well ventilated and moist air from within the dwelling to be exhausted out into the atmosphere.
THE ULTIMATE PROTECTION
Proudly Manufactured by
Thor Building Products P/L
1300 880 828
(07) 3219 6833 SALES@THORBUILDING.COM.AU 293 EARNSHAW ROAD PO BOX 14 NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
Recommended Applications and Properties Residential & Commercial Roof Insulation Duty Vapour barrier Emittance Water barrier Flammability Index < 5 Tensile Strength Machine Direction (kN/M) Tensile Strength Lateral Direction (kN/M) Edge Tear Resistance Machine Direction (N) Edge Tear Resistance Lateral Direction (N) Water Vapour Transmission Rate (Ng/Ns)
Heavy High High <5 min 12.5 min 7.5 min 80 min 80 max 2 max 0.05
Availability Width 1350MM Width 1350MM
Length 30M Length 60M
Area 40.5M 2 Area 81M 2
RHINO ROOFING RP-61Technology Solutions Information
PRODUCT INFORMATION Rhino Roofing Products are specifically manufactured to the highest industry standards.
tions and requirements for R tive Foil Laminates Satisfy BC C tions and requirements of AS/NZS 4200.1 for "Pliable Building Membranes" which is a manual recognised by the BCA Part 3.5 Roof and Cladding Low Flammability Index in accordance with AS 1530.2 < 5 Satisfy BCA Part 3.7.1 Fire Hazard Properties Satisfy Health and Safety Regulations Complies with AS/NZS 4040.4 Impact Resistance (Sandbag Test)
PRODUCT INFORMATION ROOF INSULATION - Up to R1.0 (downward heat flow) may be
added to the insulation System R-Value when Rhino Roofing RP61 is installed adjacent to an airspace in tiled roof structures. Our specialist manufacturing process bonds together Aluminium Foil and high density Kraft Paper that is then
laminated with a high strength reinforcing Polymer Mesh. Our Reinforcing Polymer Mesh is purposely-treated blue in colour tive glare problems when Rhino R to reduce r . To achieve and ensure maximum protection is attained, Flame Retardant Adhesive is applied during ocess of manufacture in all Rhino Roofing Products.
ENERGY EFFICIENCY - Rhino R -61 pro ective reductions in greenhouse gas emissions when used in an insulation agent in buildings. Preferred seasonal gains in required temperatures are assured.
RHINO ROOFING R P - 6 1
LIGHT REFLECTIVITY - Gains of up to 40% can be obtained by -61 as an exposed internal roof lining. using Rhino R ting loads are also evident. Conforms to AS/NZS 4859.1-2002. PROTECTIVE ROOF/VAPOUR BARRIER - Added protection against stormwater, condensation and wind is achieved in roof structures when applied under roof tiles. Rhino R -61 can also be a ective vapour barrier when sealed with recommended tapes. ver
RHINO ROOFING RP-61 USAGE
THE ULTIMATE PROTECTION Proudly Manufactured by
Thor Building Products P/L
1300 880 828
(07) 3219 6833 SALES@THORBUILDING.COM.AU 293 EARNSHAW ROAD PO BOX 14 NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
In all applications: • External cladding should be installed A.S.A.P • No contact is to be made with wet concrete or mortar • Store in dry area, weather proofed only after installation • Shrinkage of up to 2% can be expected In r tive foil laminate applications: • Use only in accordance with AS/NZS 4200. 2 for the "Installation Requirements for Pliable Building Membranes" • Minimum of 20MM air space is recommended adjacent to r tive foil face to achieve Maximum insulation values • 40MM sag between trusses is recommended when using -61 Rhino R • For use in enclosed structures
Recommended Applications and Properties Tensile strength - Cladding Durability - Cladding Impact Resistant - Cladding Residential &Commercial Roof Insulation Flame Retardant - Cladding Duty Vapour Barrier Emittance Water Barrier Flammability Index < 5 Tensile Strength Machine Direction (kN/M) Tensile Strength Lateral Direction (kN/M) Edge Tear Resistance Machine Direction (N) Edge Tear Resistance Lateral Direction (N) Water Vapour Transmission Rate (Ng/Ns) Emittance of Reflective Face Availability Length 30M Width 1500MM
High High High
Heavy High Reflective High <5 min 12.5 min 7.5 min 80 min 80 max 2 max 0.05 Area 45M 2
HIGH PERFORMANCE Information Technology Solutions RP-91-HP-15 PRODUCT INFORMATION Rhino Roofing Products are specifically manufactured to the highest industry standards.
"Pliable Building Membranes" which is a manual recognised by the BCA Part 3.5 Roof and Cladding Low Flammability Index in accordance with AS 1530.2 < 5 Satisfy BCA Part 3.7.1 Fire Hazard Properties Satisfy Health and Safety Regulations Complies with AS/NZS 4040.4 Impact Resistance (Sandbag Test)
PRODUCT INFORMATION ROOF INSULATION - Up to R1.0 (tiled) & R1.3 (Metal) may be is installed within an airspace in roof structures. Our specialised manufacturing process laminates Aluminium Foil with a high strength reinforcing Polymer Mesh. ENERGY EFFICIENCY used as an insulation agent in buildings.
RHINO ROOFING R P - 9 1 H
I
G
H
PERFORMANCE
THE ULTIMATE PROTECTION
LIGHT REFLECTIVITY - Gains of up to 40% can be obtained to AS/NZS 4859.1-2002. PROTECTIVE ROOF/VAPOUR BARRIER - Added protection against stormwater, condensation and wind is achieved in roof structures when applied under roof tiles or metal roofs. barrier when sealed with recommended tapes.
RHINO ROOFING (EHD) USAGE In all applications: • External cladding should be installed A.S.A.P • No contact is to be made with wet concrete or mortar • Store in dry area, weather proofed only after installation • Shrinkage of up to 2% can be expected
Proudly Manufactured by
Thor Building Products P/L
1300 880 828
(07) 3219 6833
applications: • Use only in accordance with AS/NZS 4200. 2 for the "Installation Requirements for Pliable Building Membranes" • Minimum of 20MM air space is recommended adjacent to
SALES@THORBUILDING.COM.AU 293 EARNSHAW ROAD PO BOX 14 NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
•
Maximum insulation values 40MM sag between trusses is recommended when using Rhino
•
For use in enclosed structures
Recommended Applications and Properties Tensile strength - Cladding Durability - Cladding Impact Resistant - Cladding Residential &Commercial Roof Insulation High Wind Load Protection Acoustic Performance Agent Flame Retardant - Cladding Duty Vapour Barrier Emittance Water Barrier Flammability Index < 5 Tensile Strength Machine Direction (kN/M) Tensile Strength Lateral Direction (kN/M) Edge Tear Resistance Machine Direction (N) Edge Tear Resistance Lateral Direction (N) Water Vapour Transmission Rate (Ng/Ns) Emittance of Reflective Face Availability Length 30M Width 1500MM
High High High
Extra Heavy High Reflective High <5 min 13.0 min 10.5 min 90 min 90 max 2 max 0.05 Area 45M 2
NOTE: Use in cold temperature climates (daytime < 5°C) requires roof to be well ventilated and moist air from within the dwelling to be exhausted out into the atmosphere.
Information Technology Solutions RP-51-WR MULTI PURPOSE
PRODUCT INFORMATION Rhino Wrap Products are specifically manufactured to the highest industry standards. WALL INSTALLATION - Up to R1.1 may be added to the wall system when Rhino Multi Purpose Wrap is installed as wall cladding behind brick veneer/timber cladding. ROOF INSTALLATION - Up to R1.3 may be added to insulation system when Rhino Multi Purpose Wrap is installed. Our specialised manufacturing process bonds together Aluminium Foil to a high strength reinforcing Polymer Mesh using a flame retardant adhesive. Our Reinforcing Polymer Mesh is purposely treated blue in colour to reduce reflective glare problems when Rhino Multi Purpose wrap is installed.
R H I N O M U L T I PURPOSE WALL & METAL ROOF
THE ULTIMATE PROTECTION Proudly Manufactured by
Thor Building Products P/L
1300 880 828
(07) 3219 6833 SALES@THORBUILDING.COM.AU 293 EARNSHAW ROAD PO BOX 14 NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
RHINO MULTI PURPOSE WRAP USAGE
RP-51TM TILEInformation & METALTechnology Solutions ROOFING PRODUCT INFORMATION Rhino Roofing Products are specifically manufactured to the highest industry standards.
Membranes" which is a manual recognised by the BCA Part 3.5 Roof and Cladding Low Flammability Index in accordance with AS 1530.2 < 5 Satisfy BCA Part 3.7.1 Fire Hazard Properties Satisfy Health and Safety Regulations
ROOF INSTALLATION - Up to R1.3 may be added to insulation system when Rhino RP-51TM is installed. Our specialised manufacturing process bonds together Aluminium Foil to a high strength reinforcing Polymer Mesh using a flame retardant adhesive. Our Reinforcing Polymer Mesh is purposely treated blue in colour to reduce reflective glare problems when installing Roofing Products.
RHINO TILE & METAL ROOFING USAGE In all applications:
RHINO
TILE & METAL
ROOFING RP-51TM
• • • •
External cladding should be installed A.S.A.P No contact is to be made with wet concrete or mortar Store in dry area, weather proofed only after installation Shrinkage of up to 2% can be expected
•
Use only in accordance with AS/NZS 4200. 2 for the "Installation Requirements for Pliable Building Membranes" Minimum of 20MM air space is recommended adjacent to
• • •
40MM sag between trusses is recommended when using Rhino RP-51TM For use in enclosed structures NOTE: Use in cold temperature climates (daytime < 5°C) requires roof to be well ventilated and moist air from within the dwelling to be exhausted out into the atmosphere.
THE ULTIMATE PROTECTION Proudly Manufactured by
Thor Building Products P/L
1300 880 828
(07) 3219 6833 SALES@THORBUILDING.COM.AU 293 EARNSHAW ROAD PO BOX 14 NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
Recommended Applications and Properties Residential & Commercial Roof Insulation Duty Vapour barrier Emittance Water barrier Flammability Index < 5 Tensile Strength Machine Direction (kN/M) Tensile Strength Lateral Direction (kN/M) Edge Tear Resistance Machine Direction (N) Edge Tear Resistance Lateral Direction (N) Water Vapour Transmission Rate (Ng/Ns)
Heavy High High <5 min 12.5 min 7.5 min 80 min 80 max 2 max 0.05
Availability Width 1500MM Width 1500MM
Length 30M Length 20M
Area 45M 2 Area 30M 2
RHINO BLANKET FACING (HEAVY & EXTRA HEAVY DUTY)
PRODUCT INFORMATION Thor’s Blanket Facing is made with a high strength polywoven fabric facing which is applied to a glasswool blanket whilst other products commonly use a double sided foil with fibre mesh for the facing. The polywoven fabric provides the additional benefits of:
outstanding tensile and tear
Satisfy BCA specifications and Reflective Foil Laminates
Complies with the specifications and requirements of AS/NZS 4200.1 for "Pliable Building Membranes" which is a manual recognised by the BCA Part 3.5 Roof and Cladding
Low Flammability Index in accordance with AS 1530.2 ≤ 5
strength
unrolls more easily right the way to the end of the roll an excellent visible surface finish
requirements for
Satisfy BCA Part 3.7.1 Fire Hazard Properties Satisfy Health and Safety Regulations
APPLICATION Designed for application under metal, fibre cement, and concrete roof cladding Thor’s Blanket Facing eliminates the problems associated with condensation build up on the underside of the roof cladding. The reflective foil face faces down toward the air space under the roof and prevents airborne moisture from reaching the surface of the roof cladding. NOTE: Use in cold temperature climates (daytime <5oC) requires roof to be well ventilated and moist air from within the dwelling to be exhausted out into the atmosphere. FACING OPTIONS The Duty Rating, Colour and Material Finish of the blanket facing can be varied to suit your application.
Proudly Manufactured by
Thor Building Products P/L
1300 880 828
(07) 3219 6833 SALES@THORBUILDING.COM.AU 293 EARNSHAW ROAD PO BOX 14 NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
Colour
Gloss White
Gloss Silver-Grey
Matt Dark Blue
Duty
Extra Heavy
Heavy
Heavy
Width
1350
1350
1350
Residential & Commercial Insulation Vapour barrier Emittance Water barrier
High
High
High
Reflective
Reflective
Reflective
High
High
High
Low (≤5)
Low (≤5)
Low (≤5)
Tensile Strength Machine Direction (kN/m)
min 13.0
min 12.5
min 12.5
Tensile Strength Lateral Direction (kN/m)
min 10.5
min 7.5
min 7.5
Edge Tear Resistance Machine Direction (N)
min 90
min 80
min 80
Edge Tear Resistance Lateral Directions (N)
min 90
min 80
min 80
Water Vapour Transmission Rate (Ng/Ns)
max 2
max 2
max 2
max 0.05
max 0.05
max 0.05
Flammability Index UV treated non reflective face (not direct sunlight)
Emittance of Reflective Face
by THOR BUILDING PRODUCTS
Section 7 RHINO PIR BOARD RANGE • Rhino PIR Board High performance, zero – ozone depleting insulation solution
Rhino PIR Board
Applications include: Soffit Board Cavity Wall Board All Purpose (AP) Framing Board
Rhino PIR Board Rhino PIR Board is an Australian made and tested prefabricated heat insulating elements for a variety of applications in the building and domestic industry, which consists of flexible cover sheets connected with a high bond to a cored polyisocyanurate foam. The cover sheets can be made of different materials, such as aluminium foil, mineral and glass fleeces and paper. The boards are available in thicknesses between 25 to 150 mm and lengths up to 10 meters. The polyisocyanurate foam, a three-dimensionally networked thermo set, is made from synthetic polymers, which are combined with a CFC- and HCFC free blowing agent (zero CCP) in an expansion process to form microscopic cells throughout the material. Our laminates offer a combination of structural properties and capacities of cost-effective system building and energy conservation at minimal weight along with low water absorption, thermal and acoustic insulation and good chemical resistance at good aging stability. Rhino PIR Board sets a new standard in PIR insulation system as it offers a more cost effective, high performance, - ozone depleting PIR insulated solution. Rhino PIR Board is available with Product Thickness mm 25, 27,zero 31, 42, 55, 66, 77, 88, 99 facings of, bright silver foil, craft paper and white fibreglass finish. Board Size – Length mm 2286 Rhino PIR Board has great thermal properties which will save energy for heating, cooling and lighting. Board Size – Width mm 1219 Its acoustic properties will also help in reducing noise. Reflectance (FoilRhino Side) PIR Board 96% is available in thicknesses of 25mm through to 100mm in 5mm increments.
25mm
‘R’ Value
R1.14 R1.2PIR (Fire-retardant Polyisocyanurate) R1.41200 R1.925 through to 100 in 5mm increments 2400 R2.5Silver Foil, Craft Paper, White Fibreglass R3.0Silver Foil, Craft Paper, White Fibreglass 77mm R3.5 Installation of88mm Rhino PIR Board as a concrete soffit: R4.0 Where Rhino 99mm PIR Board is exposed R4.5 to external wind loads ensure Core 27mm Width (mm) 31mm Thickness (mm) 42mm Length (mm) 55mm Interior Facing Skin 66mm Exterior Facing Skin
fasteners chosen for the install are in conjunction with AS/NZS 1170.2 Wind load standards. 1. Place Rhino PIR Board against the underside of the concrete slab. 2. Use fasteners that incorporate washers with a head diameter of not less than 35mm diameter (for example: using Hilti X-IE6 Insulation fasteners) boards can either be in a square or staggered pattern. Begin to affix the boards to the underside of the concrete in accordance with manufacturer's guidelines. Test Test Standard Result 3. Continue fixing each board following the below minimum fixing layout, each board that is Compressive Strength ASTM C1289-12 >110 Pass 2400mm x 1200mm must be fixed with no less than 8 fasteners. For the fasteners around the Thermal Conductivity ASTM C518-10 0.022 perimeter of the board must be between 50mm and 150mm from the edge of the board.
Product Testing
Cone Calorimeter Ignitability Flame Spread Heat Release Smoke Release Emmittence Water Absorbtion Water Vapour Permeance 25mm Corner Burn Test Service Temperature
AS/NZS 3837
Group 1
AS/NZS 1530.3
0/0/0/1
ASTM C1371 ASTM C1289-12
Reflective 0.1
E0.04 Pass
“The Soffit Insulation shall be Thermacon CI Max Polyisocyanurate (PIR) Foam Soffit Board mm ASTM C1289-12 3 Pass Thick comprising of a CFC/HCFC free ridged uniform closed cell PIR Foam core, bonded each side to a Fastener configuration, B per 2400mm x 1200mm board - 2.78 fixingsonIm‘. NFPA 286 Pass foil and glass mat facer, manufactured by Johns -73°C to 4. RepeatAbove the above in a continuous layer on the underside of Test steps to install the Rhino PIR Board Manville in the USA. This board is to be installed in 122°C the concrete slab. accordance with the instructions issued by 5. Tape all joins with a minimum 96mm wide Insulation tape. Following the manufacturer's Thermacon Insulation Pty Ltd.” installation guidelines. Ensure to seal around the perimeter and joins, this will prevent air flow between any air cavities formed below or above the boards.
Panel Properties Panel Thickness (mm) 25 40 50 Mass (kg/m3)** 1.3 1.9 2.2 Thermal Performance (based on NATA endorsed k = 0.020355 W/mK at 23 C) Initial 'U' Value (W/m2K) 0.81 0.51 0.41 Initial 'R' Value (m2K/W) 1.23 1.97 2.46 Panel Properties Panel Thickness (mm) 70 75 80 Mass (kg/m3)** 3.2 3.3 3.6 Thermal Performance (based on NATA endorsed k = 0.020355 W/mK at 23 C) Initial 'U' Value (W/m2K) 0.29 0.27 0.25 Initial 'R' Value (m2K/W) 3.44 3.68 3.93
60 2.8
65 3
0.34 2.95
0.31 3.19
90 3.7
100 3.8
0.23 4.42
0.2 4.91
NOTES: • Taken from NATA endorsed test report and using ISO 10456, table A.4 for the calculation of k-values at 23 deg C ••May vary depending on facing materials used. Typical value based on boards being manufactured with Aluminium Foil external facing. Craft Paper on Internal facing.
Please find the Installation Guide for: Soffit Board - Cavity Wall Board - All Purpose (AP) Framing Board on our website: www.thorbuilding.com.au
Rhino PIR Board – Use in Concrete Wall System: System calculation assumes incorporation of 100mm concrete, 70mm thick RHINO PIR Board insulation (reflective surface facing into the airspace below).
Concrete wall – Rhino PIR Board insulation directly fixed to concrete Wall (no internal lining) RT 2.9 System calculation assumes incorporation of 150mm concrete, 55mm thick Rhino PIR Board insulation (reflective surface facing internally).
Concrete wall – Rhino PIR Board insulation directly fixed to concrete Wall (with internal lining) RT 2.8 System calculation assumes incorporation of 150mm concrete, 40mm thick Rhino PIR Board insulation, 24mm reflective airspace (created using steel batten), 10mm plasterboard lining.
Rhino PIR Board – Use in Brick Veneer Wall System: System calculation assumes incorporation of 110mm clay brick, 45mm airspace, 35mm thick RHINO PIR Board insulation, 55mm reflective air space, 10mm plasterboard lining. .
Brick Veneer Wall – Rhino PIR Board insulation positioned within wall frame RT 2.8 System calculation assumes incorporation of 110mm clay brick, 45mm airspace, 35mm thick Rhino PIR insulation, 55mm reflective air space, 10mm plasterboard lining.
Brick Veneer Wall – Rhino PIR Board insulation positioned towards external side of wall frame RT 2.9 System calculation assumes incorporation of 110mm clay brick, 20mm reflective airspace, 25mm thick Rhino PIR insulation, 90mm reflective airspace, 10mm plasterboard lining.
Rhino PIR Board – Use in Brick Veneer Wall System:
Brick Veneer Wall – Rhino PIR Board insulation positioned towards internal side of wall frame RT 2.9 System calculation assumes incorporation of 110mm clay brick, 45mm airspace, 90mm reflective airspace, 35mm Rhino PIR Board insulation, 10mm plasterboard lining.
Cavity brick wall – Rhino PIR Board insulation positioned adjacent to the inner leaf RT 2.8 System calculation assumes incorporation of 110mm clay brick, 20mm reflective airspace, 35mm thick Rhino PIR Board insulation, 110mm clay brick.
by THOR BUILDING PRODUCTS
Section 8 ROCKWOOL • R hino Rockwool Fire Seal Batts provide up to 4 hours fire resistance at the junctions between the top of party walls and roof structures, and to the diverse junctions of compartment walls and floors. A highly robust mineral wool that remains stable at high temperatures.
Product:
Roxul ® Stonewool
P.D.S
Type:
FIRE PROTECTION
39
RHINO ROCKWOOL FIRE SEAL BATTS
Name:
Page 1 of 4
Description Rhino Rockwool Fire Seal Batts have been developed to provide up to 4 hours fire-resistance at the junctions between the top of party walls and roof structures, and to the diverse junctions of compartment walls and floors. It is a highly robust mineral wool that remains dimensionally stable at extremely high temperatures.
. Thickness (mm)
Dimension (mm)
Pieces per Pack
Pack Contents (m2)
100
1200 x 168
10
2.016
Product Performance and Properties
Melting point to flow of Roxul® Stonewool
Fusion Temperature:
> 1120°C fibre.
Thermal Conductivity (typical data):
Tested in accordance with DIN 52612
Mean Temp 0C
50
100
150
200
250
300
K value W/m. K
0.038
0.044
0.052
0.062
0.074
0.088
Note: The above are declared thermal conductivity performances and are based on the mean value of many Roxul laboratory and independent testing authority test results.
Fire Resistance:
Fire resistance performance was tested by CSIRO in accordance with A.S. 1530 Part 4 (Fire resistance tests of elements of building construction), and A.S. 4072-1992 (Components for the protection of openings in fire separating elements – Service penetrations and control joints. As a result of this testing a 200mm thick specimen of Roxul Party Wall Fire Stop achieved: INTEGRITY 4 HOURS INSULATION 4 HOURS REVISION:
AUSTRALASIAN INSULATION SUPPLIES
PRODUCT DATA SHEET
2
DATE OF ISSUE: April ‘04 CHKD: BH
APPV: IRS
Product:
Roxul ® Stonewool
P.D.S
Type:
FIRE PROTECTION
39
Name:
RHINO ROCKWOOL FIRE SEAL BATTS
Page 2 of 4
Fire:
Roxul® Stonewool Party Wall Fire Stop is non- combustible when tested according to international standards e.g. ASTM E-136-82, DIN 4102, BS476 Pt4-1970, ISO 1182 and IMO A 799 (19).
Corrosion Resistance: Chemical Neutrality:
Roxul® Stonewool base mineral wool is chemically neutral and will neither cause nor promote corrosion.
Corrosion Resistance: Water Leachable Chlorides:
Roxul® Stonewool base mineral wool has a very low content of water leachable chloride, approximately 6 ppm, so it can be safely used on austenitic stainless steel. Meets the requirements for use over stainless steel in accordance with ASTM C795 and of “AS-Quality” of AGI Q135.
Moisture Resistance Vapour Diffusion:
Water vapour diffusion resistance factor of µ = 1.3. This low value means that water can pass through and cool without condensing.
Moisture Resistance: Absorption from the air:
Roxul® Stonewool absorbs very little water from the air. Tests show at relative humidity of 90% for 30 days the hygroscopic water content is around .004 volume per cent. The water vapour absorption (vapor sorption) in accordance with ASTM C110 4/C 110 M is + 0.02% (vol).
Specific Heat:
Roxul® Stonewool specific heat factor is 0.84 kJ/kg per degree centigrade.
Calorific Value:
Roxul® Stonewool has a low organic matter content giving a low caloric value of around 600 kJ/kg.
REVISION: AUSTRALASIAN INSULATION SUPPLIES
PRODUCT DATA SHEET
2
DATE OF ISSUE: April ‘04 CHKD: BH
APPV: IRS
Product:
Roxul ® Stonewool
P.D.S
Type:
FIRE PROTECTION
39
Name:
RHINO ROCKWOOL FIRE SEAL BATTS
Page 3 of 4
Biological Properties:
Roxul® Stonewool contains no nutrients and therefore provides no basis for growth of fungi, moulds or bacteria, nor does it attract insects, rodents or vermin.
Durability:
Roxul® Stonewool mineral wool has been proven in services for over 50 years in all types of exposure and as such will give effective protection for the lifetime of the equipment they insulate.
Compatibility:
Roxul® Stonewool mineral wool is compatible with all materials which it is likely to come into contact in normal industrial and building applications.
Environment:
Roxul® Stonewool mineral wool presents a very effective ecological profile in all elements of manufacture, recycling use, service life and energy efficiency of material. No CFC’s or HCFC’s are used in its manufacture.
Installation Instructions:
1. Party Wall Fire Stop must be fitted as a rectangular piece, accurately butt jointed and compressed by at least 5% vertically in thickness. 2. Party Wall Fire Stop must be fitted to give a tight and accurate fit, closely following the profile of the gap. 3. Appraisal documents permit 1 or 2 layers to be used. Single layer fire stopping will always be preferred. However, double layer methods are acceptable where there is no other practical alternative. If used, 2 layers should be installed simultaneously. 4. Expansion gaps can be fire-stopped with Fire Stop Fire Damper Strip materials. The compression levels should be observed in due regard to expansion movement. 5. Installers may find simple smooth ‘slip-plates’ of benefit in installing Party Wall Fire Stop materials over rough surfaces.
REVISION: AUSTRALASIAN INSULATION SUPPLIES
PRODUCT DATA SHEET
2
DATE OF ISSUE: April ‘04 CHKD: BH
APPV: IRS
Product:
Roxul ® Stonewool
P.D.S
Type:
FIRE PROTECTION
39
Name:
RHINO ROCKWOOL FIRE SEAL BATTS
Page 4 of 4
Health & Safety Rhino Rockwool Fire Seal Batts are NOT CLASSIFIED as HAZARDOUS according to NOHSC criteria as a consequence of the following events and conclusions about the health effects of long term occupation exposure to mineral wool insulation products.
•
Over 50 years of extensive health research on Stonewool products in Europe has resulted in the scientific conclusion that there are no long term health problems from using Stonewool.
•
In March 1995 the UK Health and Safety Executive concluded that Stonewool should not be classified as a potential carcinogen.
•
Under note Q of the National Occupational health and Safety Commission (NOHSC) publication “List of Designated Hazardous Substances” (NOHSC; 10051999) the classification of NON-CARCINOGENIC is to apply.
•
Under the European Union Criteria set out in 67/548/EEC a classification of CARC, Cat O applies, ie; ”Not classifiable for carcinogenicity.”
•
Under World Health Organisation (WHO) and its Monographs Programme of the International Agency for Research on Cancer (IARC) it has been concluded that, Stonewools are now considered not classifiable as to carcinogenicity to humans (Group 3), It recommended that for the handling and installation of Roxul® Stonewool the internationally recognized Material Safety Data Sheet be followed; These are readily available from Australasian Insulation Supplies Pty Ltd.
For further information and technical advice on insulation contact: A.B.N. 12 088 560 392 A.C.N. 088 560 392 Address: 293 Earnshaw Road, Northgate QLD 4013 Postal Address: PO Box 14, Northgate QLD 4013 Ph: (07) 3246 2200 Fax: (07) 3219 6833 REVISION: AUSTRALASIAN INSULATION SUPPLIES
PRODUCT DATA SHEET
2
DATE OF ISSUE: April ‘04 CHKD: BH
APPV: IRS
by THOR BUILDING PRODUCTS
Section 9 ACCESSORIES • S afety Mesh Galvanised wire with tensile strength of 450mpa. Safety Mesh can be used on Factories, Warehouses, Shopping Centres, Schools, office Blocks, Sheds and much more. • R oof Razor Wide enough to walk on, the fastest spacer to install. Pre-loaded screws. Suitable for all roof sheet profiles including pierced and concealed fix. Suitable for glass wool or polyester 1200mm wide to suit the blanket. Cyclonic version available with higher screw pull-out capacity. Made in Australia, patent pending design.
Information Technology Solutions
SAFETY MESH PRODUCT INFORMATION
Original roofing mesh that was developed and tested to provide the industry standard described in the AS/NZS 4389 and ALL State Code of Practices for Safe Working on Roofs.
Original roofing mesh that was developed and tested to provide the industry standard described in the AS/NZS 4389 and ALL State Code of Practices for Safe Working on Roofs.
Can be used on the following roofs: Factories Shopping Centres Hospitals/Aged Care Facilities Sheds Warehouses Schools Office Block
Specifications:
Proudly Manufactured by
Thor Building Products P/L
1300 880 828
(07) 3219 6833
1800 WIDE
2250 WIDE
2400 WIDE
PVC1800
Weight per 50m
24kg
29kg
31kg
28kg
Weight per metre
0.48kg
0.58kg
0.62kg
0.56kg
Sqm per roll
90
112.5
120
90
Sqm with one lap
82.5
105
112.5
82.5
Sqm with double lap
75
97.5
105
75
50m rolls per pallet
25
25
25
16
Roofing Mesh consists of 2mm galvanised wire with a tensile strength exceeding 450mpa. The longitudinal wires are spaced at 150mm centres with cross wires spaced at 300mm centres. The rolls are available either 1800mm, 2250mm or 2400mm wide and are supplied in standard 50metre rolls or cut to the length of the roof run.
SALES@THORBUILDING.COM.AU 293 EARNSHAW ROAD PO BOX 14 NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
The product is also available PVC-coated for use in corrosive environments.
Information Technology Solutions
ROOF RAZOR PRODUCT INFORMATION
Raise the roof or create an open space between two planes with the Roof Razor. Suitable for roofing, walling and flooring this versatile and robust solution has endless possibilities. The unique design will also slice through glass wool insulation allowing it to recover to its full nominal thickness.
Raise the roof or create an open space between two planes with the Roof Razor.
The unique design of the legs means that the screws not only come pre-loaded, but are also encased within the legs. The legs guide the fixings to the purlinand stop the polyester fibres from spinning or being entangled around the screws. Key advantages of the Roof Razor system 68.4mm surface width Horizontally opposed fixing points provide a strong and Compatible with all brands of roofing clips, and all roofing profiles One piece system 1200mm length to suit building blanket width Suitable for walling Supplied fully assembled and pre-loaded with screws Tiny contact areas reduce loss of R-value to less than 1% Legs are sharp enough to cut throughtthe wool like a knife
Proudly Manufactured by
Thor Building Products P/L
1300 880 828
(07) 3219 6833 SALES@THORBUILDING.COM.AU 293 EARNSHAW ROAD PO BOX 14 NORTHGATE QLD 4013
WWW.THORBUILDING.COM.AU
THERMAL PERFORMANCE Voids create thermal bridging No Fully compressed wool, total loss of R-Value less than 1% Significantlyincreased R-value when using the Roof Razor System ... and it won't loosen over time
by THOR BUILDING PRODUCTS