Technical Submittal - Quantum SOS Pedestal

Page 1

QUANTUM SOS PEDESTAL

QUANTUM SOS PEDESTAL High quality, robust, marine grade anodised aluminium SOS pedestals featuring a range of emergency equipment.

TECHNICAL SUBMITTAL

WORLD LEADING SPECIALISTS IN GLOBAL MARINA SOLUTIONS


Contents

Contents Contents..............................................................................................................2 Standard Layout..............................................................................................3 Assembly Drawing........................................................................................ 4 Parts List.............................................................................................................5 Data Sheets........................................................................................................6 Pedestal.........................................................................................................6 100 mA Switchgear..................................................................................8 6kg Fire Extinguisher..............................................................................9 Projects in the Middle East....................................................................... 12 Products In-Situ.............................................................................................14 Certification..................................................................................................... 16 BSI Test Report........................................................................................ 16 IK10 Impact Test Report.....................................................................20 Certificate of Conformity................................................................... 23


360mm

262.5mm

382.5mm

Side (left)

Front

1000mm

1190mm

Standard Layout

260mm

360mm

260mm

360mm

262.5mm

382.5mm

FIRST AID

POWDER FIRE EXTINGUISHER

6KG POWDER STORED PRESSURE USE EXTINGUISHER UPRIGHT PULL RING PIN AIM AT BASE OF FIRE

SQUEEZE LEVER SWEEP SIDE TO SIDE

A

B

C

ZZZZ ZZZZzzz zZZZZZ ZZZZ ZZZZzzz zZZZZZ z zZZ zZ ZZZZzzz zZZ ZZ Z zzZZ zzzzz z ZZZ ZZZ ZZZZZ ZZ zzzz ZZZ ZZZ ZZZZZ ZZ zzzz zz z Z z ZZZ ZZZ ZZZ ZZZZZ zz zZZZ zZZ zzz.zzzzzzz.zzz zzZz zzz zzZ Z Z zz Z ZZZ zzz zZ Z ZzzZ ZZ z ZZ Z ZZZZ ZZZZ ZZZ ZZZ ZZZZZ ZZ zzz.zzzzzzz.zzz

382.5mm

Front (open)

Side (right)

Reverse


Assembly Drawing

01

02 03

10

11

04

12

05

06

07 08

09


Item

Quant.

Product Description

Product Code

01

1

Photocell

ACLG0050

02

10

Star LED

ACLG0237

03

1

12W LED Driver

ACLG0330

04

1

First Aid Kit

EEAA0070

05

1

6kg Fire Extinguisher

EEAA0030

06

1

DIN Rail

ACEV0240

07

1

6amp 100mA 2pole RCBO

ACEQ0040

08

1

Single Phase Incoming Terminals

ACEV0095

09

1

Switchgear Enclosure

10

1

30" Life Buoy

EEAB0010

11

1

10m Floating Throwing Rope

EEAB0030

12

3

Life Buoy Hook

w/ above

Parts List

No


QUANTUM SOS PEDESTAL

The QUANTUM SOS PEDESTAL Range A range of high quality, robust marine grade anodised aluminium SOS pedestals.

PRODUCT FEATURES • 25 micron marine grade 6065 anodised extruded aluminium body • Powder-coated aluminium panels and door • High impact resistant UV stabilised polycarbonate lighting lens assembly • 360 degree low energy LED lighting • Heavy duty polycarbonate base • Fully segregated lighting and emergency compartments • Designed for ease of installation and maintenance • Optional equipment; • Life ring & floating throw rope • Fire extinguishers, fire blankets & fire axes • First aid kits • Emergency beacons & sounders

Internal Compartment

UV Stabilised

CE Certified

IP66 Weather Proof

IK10 Impact Resistant

LED Illumination


SPECIFICATIONS

92.5mm

760mm

260mm

360mm

Dimensions

Pedestal: 382.5mm x 1190mm x 262.5mm (W x H x D) Life Buoy: 760mm x 760mm x 92.5mm (W x H x D)

Operating Temperature -30°C to +60°C (Installed and Operated Within Multiple Climates from Around the Globe)

IP Rating

IP66 BS EN 60529

Impact Rating

IK10 BS EN 62262:2002

Compliances

BS7671 Wiring Regulations BS EN 61439-2:2011, BS EN 61439-5:2015 CE Certified Low Voltage Directive 2014/35/EU BS EN IEC 60947-1 / BS EN IEC 60947-3 Electromagnetic Directive 2014/30/EU UV Stabilised Flame Retardant to UL94 Flame Rating at V2

Typical Weight (AVG)

20-25kg

1190mm

Head: FR-VS UV Stabilised Polycarbonate Body: Alloy 6063 BS EN 10204:2004, BS EN 573-3:2013, BS EN 755-2:2016

1000mm

Materials

175mm

CHARACTERISTICS

382.5mm

262.5mm

LIGHTING Type

360 Degree Low Energy LED

Rating

4000k 10x1 Watt

Protection

RCBO 6AMP

OPTIONS • Life ring and floating throw rope

• Fire axes

• Fire extinguisher (Dry powder or water)

• Emergency beacons & sounders

• First aid kits

• Photocell controlled lighting

• Fire blankets

Images are for marketing purposes only and are not contractual © 2017

Head office contact: t: +44 (0) 1205 724754 f: +44 (0) 1205 724876 rolec@rolecserv.co.uk

Rolec Services Ltd Ralphs Lane, Frampton West Boston, Lincolnshire UK. PE20 1QU

MSDS-0009

@RolecMarina

www.rolecserv.com


Residual Current Circuit Breaker With Overload Protection 6/16/32A 100mA 1P+N Type AC

Provides protection against earth fault/leakage current, short circuit, overload, function of isolation. Provides complementary protection against direct contact by human body. Effectively protects electric equipment against insulating failure. Provides comprehensive protection for household and commercial distribution systems.

TECHNICAL DATA • Rated current(In): 6, 16, 32A • Rated voltage(Un): 230/240VAC • Breaking capacity(Icn): 6kA • Rated frequency: 50/60Hz • Rated residual current: 100mA Overall Dimensions (mm)

• Tripping characteristics: C • Number of poles: 1P+N

71

• Electrical endurance: 4000 cycles • Terminals: pillar type

N

• Cable termination: 25mm2

Line

• Torque of screw: 2.5Nm

ACEQ0120

C16

Test Monthly

82.8

• Standards: IEC/EN 61009-1

6000 3

• Approval / marking:

-25

I n : 100mA Un : 230V~

45

• IP degree: IP20

IEC 61009-1 EN 61009-1

N

Product Codes: ACEQ0040

C6AMP 100mA 1P+N TYPE A/C RCBO

ACEQ0120

C16AMP 100mA 1P+N TYPE A/C RCBO

ACEQ0170

C32AMP 100mA 1P+N TYPE A/C RCBO

Head office contact: t: +44 (0) 1205 724754 f: +44 (0) 1205 724876 rolec@rolecserv.co.uk

60

35.5

• Mechanical endurance: 10,000 cycles

Rolec Services Ltd Ralphs Lane, Frampton West Boston, Lincolnshire UK. PE20 1QU

Load

50 66

ACEQD-0040/0120/0170

www.rolecserv.com





Projects in the Middle East

Abu Dhabi

Dubai

• Al Bandar

• Dubai Marina Mall

• Volvo Ocean Race Marina

• Dubai Creek Golf and Yacht Club

• Yas Race Track Marina

• Dubai International Marina Club

• Eastern Mangrove Marina

• Jumierah Beach Hotel Resort

• Fairmont Hotel Marina

• Dubai Marina

• Abu Dhabi Sports Club

• Dubai Maritime City

• Al Bateen Jetty

• Dubai Festival City

• Dhow Harbour

• Al Seef Marina

• Emirates Palace Marina

• Anchor Marinas, Palm Islands

• HH Sheikh Sultan Bin Zayed Al

• Logo Island Private Marina

Nayhan private mooring

• Coastguard Shindagha

• Palace Marina

• RTA Water Ferry

• Port of Abu Dhabi

• NMDC Dhubbayah

• Zaafarana

• Royal Mirage Palace Pier

• Ser Banyas Island

• Port Rashid

• Marfa Port

• Dubai Water Canal

• Arzannah Island

• Bulgari Marina

• Sila Harbour

• Marsa Al Seef

• Delma Island

• Bluewaters Island

• Khalifa Port Project

• Culture Village Marina

• Mirfa Port

• Ommiyat Jetty

• Al Mirfa

• Skydive Dubai

• Abu Dhabi International Sports Club

• Deira Islands

• Al Reem Island

• Jewel of the Creek

• Al Sadr Coastguard School Phase 2

• Jumeirah Private Islands

• Ghantoot Marina Resort • Jebel Dhana

Umm Al Quwain

• Mina Zayed

• Al Rafaah

• Presidential Palace RMB • Sea Palace

Fujairah

Sharjah • Al Hamriyah • Sharjah Aquarium Marina

• Fujairah Marina

• Port of Fujairah

Ras Al Khaimah • Al Hamra Marina

• Al Jeer Marina

Ajman • Al Ajman

• Al Zorah


Qatar

Oman

• Lusail Marina

• Sifah Marina

• Doha Corniche

• Royal Yachts of Muscat

• Westbay Hotel Complex • Four Seasons Hotel Marina

Lebanon

• Salam

• Movenpick Marina

• Ritz Carlton Hotel Marina

• Joseph Khoury Marina

• Porto Arabia, The Pearl

• Jounieh Yacht Harbour

• Viva Bahriya, The Pearl

• Summerland Marina

• Costa Malaz, The Pearl

• ATCL

• Island Marina • The Base

Saudi Arabia

• South Marina Yacht Club

• Ba Hareth

Kuwait

• Half Moon Bay Marina • Juffali Beach Villa Works

• Fintas Coastguard Headquarters

• SWCC Shoaiba (Sharma Duba), Jeddah

• Feheheel

• KAUST Marina

• Kuwait Ministry Private Moorings

• KSA Border Guard

• Ras Al Ard Terminal Marina

• Bay La Sun

• Umm Al Maradem

• Darren Marina

• Phase V Salmiya • Police Officers’ Club

Egypt

• Sheikh Jaber

• Hurghada Marina

• Citadel Marina

Jordan

• El Gauna

• Tala Bay Marina

• Naval Base

• Ayla Marina

• Abu Tig Marina

Bahrain • Amwaj Marina

• Durrat Marina • Marina Club Bahrain • Durrat Private Jetties • Hawar Island • Reef Island • Royal Court • Al Khiran Tourist Park • Sa’ada Marina


Products In-Situ

Clearwater Bay Golf & Country Club, Hong Kong

Bluewaters Island, Dubai


South Marina Yacht Club - Lusail, Qatar

Haslar Marina, UK


Certification

   









      

 

 

  





     

  

  

    







        

 


  

 

  

                                                                                         


          



 

  

  

     



       

 

    


    

  

  

  

                                                 

           


Test Report Number 4E10008 Issue 1

2379

Page 1 of 3

Date of Issue:

16/07/2019

Product Assessment and Reliability Centre Ltd Unit 4 Alverdisco� Road Industrial Estate Bideford, Devon, EX39 4LQ Telephone: +44 (0) 1237 421255 info@parctest.co.uk www.parctest.co.uk

Reason for Re-issue

N/A

Commercial in Confidence

Date Samples Arrived: Date Tes�ng Started: Date Tes�ng Completed:

02/07/2019 09/07/2019 10/07/2019

Customer Purchase Order No:

NPO 32399

Customer Name and Address:

Iden�ty/Serial Numbers: Fin Quantum

Descrip�on of Test Samples: 1 off Fin Charging Point 1 off Quantum Charging Point Test Performed: IK10 Impact Test

Holly Brown Rolec Services Ltd Ralphs Lane Frampton West Boston PE20 1QU

UKAS

In Accordance With: BS EN 62262:2002

Report Summary: The sample content was subjected to the test outlined above, the details of which are contained in this test report. Prior to tes�ng, the impact loca�ons for both samples were marked up and sent to the customer for review. The customer approved the impact loca�ons in an email dated 05/07/2019. The impact loca�ons can be found in sec�on 3.1.2 of this report.

Distribu�on: 1. PARC Ltd File 2. Holly Brown

Test Engineer:

Tom Josling

Sample Disposal: Sample/s returned to customer via courier

Approved by:

Sam Wort, Senior Technical & Quality Engineer

Digitally signed by Tom Josling Date: 2019.07.16 09:32:59 +01'00' Digitally signed by Sam Wort Date: 2019.07.17 09:35:43 +01'00'

This report shall not be reproduced, except in full, without the written approval of the testing laboratory. PARC performs all its product testing under a rigorous Quality Management System. PARC is accredited by UKAS to BS EN ISO/IEC 17025:2005, the "General Requirements for the Competence of Testing and Calibration Laboratories". Details of PARC’s UKAS accredited tests and a copy of its UKAS Schedule of Accreditation are available upon request. Tests marked "non-UKAS" are currently not covered by PARC’s UKAS 17025:2005 accreditation. All testing, whether UKAS or non-UKAS, is performed within the same Quality Management System and to the same levels of calibration and traceability. The results contained in this report relate only to the samples tested. Any opinions expressed within this report are not included in the UKAS Accreditation Schedule for this Laboratory. DOC REF: TR2_L


Test Report Number 4E10008 Issue 1

2379

Page 2 of 3 1.

Date of Issue:

16/07/2019

Product Assessment and Reliability Centre Ltd Unit 4 Alverdisco� Road Industrial Estate Bideford, Devon, EX39 4LQ Telephone: +44 (0) 1237 421255 info@parctest.co.uk www.parctest.co.uk

Reason for Re-issue

N/A

Commercial in Confidence

Sample Content

Descrip�on of Test Samples: 1 off Fin Charging Point 1 off Quantum Charging Point 2.

Iden�ty/Serial Numbers: Fin Quantum

Ini�al Inspec�on

The sample content exterior was subjected to an ini�al visual inspec�on (non-UKAS). No obvious damage was noted. 3.

Test Procedure

3.1

IK10 Impact Test

3.1.1 Test Defini�on The sample content was subjected to an IK10 impact test in accordance with BS EN 62262:2002; the following condi�ons were applied: • • • • •

Number of impacts: 5 per exposed face Faces to impact: 4 sides per Sample Fin Drop surface: Aluminium plate & Concrete Quantum Drop surface: Aluminium plate IK10 impact test – 20 J force, 5 kg mass dropped from 400 mm.

3.1.2 Test Photos

Impact Loca�ons Example - Fin

Impact Loca�ons Example - Fin

Impact Loca�ons Example - Quantum

This report shall not be reproduced, except in full, without the written approval of the testing laboratory. PARC performs all its product testing under a rigorous Quality Management System. PARC is accredited by UKAS to BS EN ISO/IEC 17025:2005, the "General Requirements for the Competence of Testing and Calibration Laboratories". Details of PARC’s UKAS accredited tests and a copy of its UKAS Schedule of Accreditation are available upon request. Tests marked "non-UKAS" are currently not covered by PARC’s UKAS 17025:2005 accreditation. All testing, whether UKAS or non-UKAS, is performed within the same Quality Management System and to the same levels of calibration and traceability. The results contained in this report relate only to the samples tested. Any opinions expressed within this report are not included in the UKAS Accreditation Schedule for this Laboratory. DOC REF: TR2_L


Test Report Number 4E10008 Issue 1

2379

Page 3 of 3

Date of Issue:

16/07/2019

Product Assessment and Reliability Centre Ltd Unit 4 Alverdisco� Road Industrial Estate Bideford, Devon, EX39 4LQ Telephone: +44 (0) 1237 421255 info@parctest.co.uk www.parctest.co.uk

Reason for Re-issue

N/A

Commercial in Confidence

3.1.3 Test Results/Plots

Fin – Typical Post Impact - Edge

Quantum – Typical Post Impact - Edge

This report shall not be reproduced, except in full, without the written approval of the testing laboratory. PARC performs all its product testing under a rigorous Quality Management System. PARC is accredited by UKAS to BS EN ISO/IEC 17025:2005, the "General Requirements for the Competence of Testing and Calibration Laboratories". Details of PARC’s UKAS accredited tests and a copy of its UKAS Schedule of Accreditation are available upon request. Tests marked "non-UKAS" are currently not covered by PARC’s UKAS 17025:2005 accreditation. All testing, whether UKAS or non-UKAS, is performed within the same Quality Management System and to the same levels of calibration and traceability. The results contained in this report relate only to the samples tested. Any opinions expressed within this report are not included in the UKAS Accreditation Schedule for this Laboratory. DOC REF: TR2_L


CERTIFICATE OF CONFORMITY

CERTIFICATE OF CONFORMITY

CERTIFICATE OF CONFORMITY

THIS STATEMENT IS A DECLARATION STATING THAT THE PRODUCT KNOWN AS THE:

ROLEC QUANTUM SERVICE PEDESTAL PRODUCED BY:-

ROLEC SERVICES LTD, RALPHS LANE, FRAMPTON WEST, BOSTON, LINCOLNSHIRE, ENGLAND. PE20 1QU

IS MANUFACTURED IN COMPLIANCE WITH THE FOLLOWING EU DIRECTIVES: (A) THE LOW VOLTAGE DIRECTIVE 2014/35/EU (B) THE ELECTROMAGNETIC DIRECTIVE 2014/30/EU AND AS SUCH CARRIES THE

Tel: 01205 724754 QUALITY

RELIABILITY

INNOVATION

MARK OF CONFORMITY

Email: rolec@rolecserv.co.uk

Web: www.rolecserv.com CCEMR2-001


THE WORLD’S LEADING MARINA SERVICES SPECIALIST

t: +44 (0) 1205 724754 e: rolec@rolecserv.co.uk

@RolecMarina www.rolecserv.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.