ABSTRACT The main goal of this system was to develop a robust monitoring and control system capable of maintaining the physiological parameters of the anesthetized animal in a predetermined range, using the instrumentation already present in the laboratory, and based on the Lab VIEWR software interface. A single user interface was developed that allowed for monitoring and control of key physiological parameters including body temperature (BT), mean arterial blood pressure (MAP) and end tidal CO2. Embedded within this interface was a fuzzy logic based control system designed to mimic the decision making of an anesthetist. The system was tested by manipulating the blood pressure of a group of anesthetized animal subjects using bolus injections of epinephrine and continuous infusions of phenylephrine (a vasoconstrictor) and sodium nitroprusside (a vasodilator). This testing showed that the system was able to significantly reduce the deviation from the set pressure (as measured by the root mean square value) while under control in the hypotension condition (p < 0.10). Though both the short-term and hypertension testing showed no significant improvement, the control system did successfully manipulate the anesthetic percentage in response to changes in MAP. Though currently limited by the control variables being used, this system is an important first step towards a fully automated monitoring and control system and can be used as the basis for further research. EXISTING SYSTEM The existing system is only monitoring the human health conditions. The old existing system is low efficiency so we need good efficiency health monitoring system. But the new proposed system is used monitor and control the oxygen level depends upon the instructions with good efficiency. This system is fully automated. Office Address: No 4 / Flat No 3D, Sai Kiran Apts, First Main Road, Kasturba Nagar, Chennai-20 web: www.zebros.in e mail : zebrosprojects@gmail.com mob: 99400 98300


ZEBROS PROJECTS BLOCK DIAGRAM

CONTACT: ZEBROS PROJECTS PHONE: 9940098300, 9500075001

DESCRIPTION The testing of this technology in-vivo depends critically on the stability of the anesthetized animal. That is, if the systemic physiological parameters are not tightly controlled, it is exceedingly difficult to assess the precision and accuracy of the PLI system or interpret the consequence of disease. Any variation in physiological parameters such as Blood Pressure (BP), Body Temperature (BT) and Pulmonary Function (pO2 and pCO2 levels) can be a potential source of variation in the data being gathered using PLI. In order to ensure that all measurements taken using PLI are not affected by fluctuations in the systemic physiological state, each animal must be maintained within a tightly controlled physiologic range. The main goal of this project was to develop a robust monitoring and control system capable of maintaining the physiological parameters of an anesthetized animal in a predetermined range, using the instrumentation already present in the laboratory, and based on the LabVIEWTM software interface. In order to achieve the above goals a design had to be developed that allowed for the most elegant solution possible. A fuzzy logic control strategy was developed to mimic the decision making of an anesthetist allowing for the automated maintenance of ETCO2 and BP. The monitoring, control and file transfer systems were developed in Lab VIEWTM and combined to create a single user interface. This interface was tested on a total of ten rats in both short and log-term perturbation experiments using bolus and maintained drug infusions to mimic various systemic physiological conditions. Office Address: No 4 / Flat No 3D, Sai Kiran Apts, First Main Road, Kasturba Nagar, Chennai-20 web: www.zebros.in e mail : zebrosprojects@gmail.com mob: 99400 98300


ZEBROS PROJECTS This testing revealed that the system had limited abilities to control short-term perturbations but was able to significantly reduce the deviation of the mean arterial blood pressure (MAP) from the control set point in simulated hypotension experiments.

ADVANTAGES 

Low power

Low cost

Good efficiency

Less noise

APPLICATIONS 

Hospital applications

Healthcare applications

Sports applications

Security applications

ZEBROS PROJECTS SOFTWARE BASED

HARDWARE BASED

Networking

VLSI

Data Mining

Mat lab

Grid Computing

Robotics

Network Security

Embedded

Image Processing

Bio Medical

Web Applications

Power Systems

Mobile Computing

Power Electronics

Software Engineering

Java with Embedded

Office Address: No 4 / Flat No 3D, Sai Kiran Apts, First Main Road, Kasturba Nagar, Chennai-20 web: www.zebros.in e mail : zebrosprojects@gmail.com mob: 99400 98300


ZEBROS PROJECTS Cloud Computing

Android

What is IEEE? The Institute of Electrical and Electronics Engineers or IEEE (read eye-triple-e) is Incorporated in the State of New York, United States. It was formed in 1963 by the merger of the Institute of Radio Engineers (IRE, founded 1912) and the American Institute of Electrical Engineers (AIEE, founded 1884). A membership organization comprised of engineers, scientists and students that sets standards for computers and communications. It is a nonprofit organization with more than 365,000 members in around 150 countries. The IEEE describes itself as "the world's largest technical professional society -promoting the development and application of electro technology and allied sciences for the benefit of humanity, the advancement of the profession, and the well-being of our members." Why IEEE based projects?   

It grantees for standard It assured latest solution for problems It delivers new patented technologies at an ever-increasing pace

It access world-class technical information provided by the IEEE and cut down your research time.

OUR FEATURES

 24*7 Call Support  Project Execution through Remote System  20 Days Technical classes taken by Corporate Trainer Office Address: No 4 / Flat No 3D, Sai Kiran Apts, First Main Road, Kasturba Nagar, Chennai-20 web: www.zebros.in e mail : zebrosprojects@gmail.com mob: 99400 98300


ZEBROS PROJECTS  Unlimited Project & Technical Support through your academic  Project software Installation support

PROJECT SUPPORT 0th Review        

Abstract Existing System Disadvantages Proposed System Advantages Objective System Requirements System Architecture 2nd Review

       

Use case Diagram Class Diagram Collaboration Diagram Sequence Diagram Activity Diagram Testing & test cases Partial Code Screenshot for First two module  Review Document Explanation Final Review

1st Review        

Literature Survey Module List Module Description Data Flow Diagram Level DFD Module Wise DFD Problem Definition Review Document Explanation 3rd Review

      

Conclusion References Future Enhancement 65% code (Executable Format) Required Software Review Document Explanation

 Complete Code with Enhancement  Final Document (University Standard Format)  Complete Explanation for Project Concept & Code

Office Address: No 4 / Flat No 3D, Sai Kiran Apts, First Main Road, Kasturba Nagar, Chennai-20 web: www.zebros.in e mail : zebrosprojects@gmail.com mob: 99400 98300


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.