Conventional Fire Alarm Systems

Page 1

Conventional Fire Alarm Systems


Contents

Introduction Premier SX Conventional Fire Alarm Panel Premier Elite Conventional Fire Alarm Panel

8

9

Zeta UV/IR Optical Flame Detectors

26-27

Zeta Conventional Manual Call Points

28

Zeta Conventional Weatherproof Call Point

29

30

Premier Conventional Repeater Panel

10

Zeta Conventional Explosion Proof Manual Call Point

Premier M Plus 8-24 Zone Conventional Fire Alarm Panel

11

Miditone Conventional Electronic Sounder

31

Premier M Plus Repeater Panel

12

Miditone Conventional Combined Electronic Sounder & Flasher

32

Premier 48 M Plus 24-48 Zone Conventional Fire Alarm Panel

13

Securetone Conventional Electronic Sounder

33

Premier 48 M Plus Repeater Panel

14

Secure Light Xenon Flasher

34

Premier MX Conventional Fire Alarm Panel

15

Maxitone Conventional Sounder and Combined Sounder & Flasher

35

Fyreye Extra Conventional Optical Smoke Detector

16

Zeta Conventional Fire Alarm Bells

36

Zeta Flame Proof Siren

37

Zeta Flame Proof Gong Bell

38

Zeta Magnetic Door Holders

39

Zeta Duct Unit

40

Fyreye Extra Conventional Rate of Rise and Fixed Heat Detectors

2

3-7

17

Fyreye Extra Conventional Opto-Heat Detector

18

Fyreye Conventional Ultra-Violet Flame Detector

19

Fyreye Conventional Detector Bases

20

Premier Power Pack EN 54-4 Power Supply with LCD Screen

41

Zeta Remote LED Indicator

21

Batteries

42

Fyreye 50 & 100m Reflective Beam Smoke Detector

22-23

Fyreye 50 & 100m Auto-aligning Beam Smoke Detector Systems 50 & 100m

24-25


Introduction Zeta Alarm Systems, a trading name of GLT Exports Ltd, was founded in 1985 and is a privately held UK manufacturer of Fire Alarm, Gas Detection and Emergency Systems. Our brand name is well known throughout the industry and is acclaimed in over forty countries worldwide. We are currently represented in the UK, Europe, Africa, the Middle East, Southern Asia & South America and this list continues to grow.

Complete System Supplier

Research & Development

To meet the requirements of our ever-changing market, we pride ourselves on being a complete system supplier. This means our customers can rely on us for their entire system requirements.

As with all electronic equipment there is an ever present drive to manufacture products that are increasingly effective whilst becoming more cost sensitive. To meet this objective we spend a significant percentage of our profits on the continued development of products, whether it be introducing new items, or improving existing ones. We have a team of engineers & designers all of whom have vast industry knowledge & experience.

One of the main advantages of using a complete system supplier, compared with a component supplier, is that system wide compatibility is assured and there is one point of contact. Marketing our products as systems has played a vital role in our worldwide success.

The Future Our continued inward investment and constant endeavour to offer the very best products is recognised by our increased turnover and profit margin year-onyear. Our mission is to support our existing & future customers by providing them with the highest quality products, at the most competitive prices.

Customer Support & Product Warranty

As a manufacturer we always follow the market needs closely to evaluate how we should adapt our product range. This, combined with welcomed customer feedback, has proved to be a successful formula for meeting the current and future industry needs.

Statement Of Quality Policy We maintain a Quality System, which conforms to BS EN ISO9001:2008. We are committed, where applicable, to manufacture in compliance with all appropriate legislation & regulatory requirements.

We value our customers greatly and to ensure they have the best experience we have a dedicated support team who are able to assist with sales, technical or logistical queries. Our products carry a full 24 month manufacturers’ guarantee from the date of purchase. Our network of authorised agents is fully trained on the use of our products and will provide a helpful & friendly service.

3


Introduction to Fire Alarm Systems

Fire Detection & Alarm Systems BS5839

Fire alarm systems are used to detect a fire, and to signal a warning alarm to the appropriate source.

Risk Assessment

In general, there are 3 types of system; 1. Manual Fire Alarm Systems – which rely on manual call points to signal an alarm 2. Life Protection Fire Alarm Systems – these are designed to protect the occupants of a building 3. Property Protection Fire Alarm Systems – these are designed to protect buildings

The warning may be simply ringing fire alarm sirens, however if a building is likely to be unoccupied, it may be more appropriate to signal to a monitoring station, or at least send a message to the building owner via telephone.

The ‘Fire precautions (Workplace) Regulations’ require any business employing five or more persons to hold a written ‘Fire Risk Assessment’ and ‘Emergency Plan’. This must be periodically reviewed. The local fire brigade can enforce compliance, and close any building that does not meet this act. In the event of a fire in a building without a written ‘Fire Risk Assessment’, those responsible may face fines and imprisonment, and/or private litigation. What the law requires you to do: Complete a fire risk assessment for your work place (considering all employees, the public, disabled people and people with special needs). Identify and record any significant findings or persons at risk. Provide and maintain fire precautions. Provide information, instruction and training. Nominate persons responsible to implement your emergency plan. Consult employees about the above nominations and your proposals to improve fire precautions. Inform other employees who may have work places in the building about any significant risks which may affect their safety and co-operate with them to reduce/control these risks. If you are not an employer, but control premises which contain more than one workplace, you are responsible for complying with fire regulations. You must establish a suitable means of contacting the emergency services. Your employees must co-operate to ensure the workplace is safe from fire and its effects.

4


System Zoning Information In order to aid identification of the source of a possible fire, the protected building should be divided into ‘zones’. When deciding on a suitable zoning scheme for a building, consideration should be given to the size, any existing fire routines, escape routes, zone accessibility, and structural fire compartmentation.

The following guide lines should be observed: If the total floor area of the building is less than 300m2 then the building needs only one zone, regardless of the number of storeys.

Manual Call Points A ‘Manual Call Point’ is a device which enables personnel to raise an alarm in the event of a fire incident by pressing a frangible element to activate the alarm system. Manual Call Points should be installed at a height of 1.2m above floor level at easily accessible, conspicuous positions, on exit routes, at the entry floor landings of staircases and at all exits to the open air.

If the total floor area is greater than 300m2: The maximum area for a zone is 2000m2 If a stairwell (or similar) extends beyond one floor it should be a separate zone. If a zone covers more than one fire compartment then the zone boundaries should follow the compartment boundaries. The search distance within the zone in order to ascertain the position of the fire should not exceed 60m. Remember that the use of Remote Indicator lamps may help to reduce the distance travelled.

1.2m - 1.4m

Manual Call Points should be spaced so that one may always be found within a maximum distance of 45m apart or 25m for disabled person.

45m Max. or 25m Max. for disabled person

60m Max.

If a building is divided between occupiers, zones must not be shared between them.

5


Detector Information Automatic Detectors When deciding on the type of detector to be used in any area it is important to remember that the detector has to discriminate between a genuine fire and the normal conditions existing therein.

Smoke Detectors

Heat Detectors General

In open spaces under flat horizontal ceilings, every point should lie within 7.5m of a smoke detector.

In open spaces under flat horizontal ceilings, every point should lie within 5.3m of a heat detector.

10.6m

7.5m

112m² (10.6m x 10.6m)

56.3m² (7.5m x 7.5m)

Room boundary

7.5m

5.3m

5.3m

Smoke detection should be generally avoided in the following areas to avoid unwanted alarms. They should be protected by means of other detectors such as heat detectors. Contamination in dusty areas may cause unwanted alarms and reduce the life of the detector. Damp or humid conditions such as showers, bathrooms and external areas should be avoided as the water vapour may cause unwanted alarms and reduce the life of the detector. Detectors should not be mounted where gases, vapours or fumes are present. Detectors should never be used at low temperature where ice or condensation can affect detector sensitivity. Kitchens, garages, welding shops and boiler houses should generally be avoided.

6

Room boundary

3.8m

Heat detectors are designed to either detect a rapid rise in temperature or to operate at a fixed temperature. Although they provide a slower response time than smoke detectors they do provide a method of protection for areas where smoke detectors cannot be used. Heat detectors should not be used for the protection of life or where extensive property loss may be expected.

‘Rate of Rise’ Heat Detectors ‘Rate of Rise’ heat detectors respond to both rapid increases of temperature and to fixed top temperature.

‘Fixed Temperature’ Heat Detectors Fixed temperature heat detectors are available with different temperature settings, and are normally installed in kitchens, boiler rooms, etc.


Detection In Apex Roofs

Fire Alarm Sounders

If the ceiling is pitched or sloping, smoke will tend to rise towards the highest point (apex) of the roof, therefore detection should be placed in the apex. As the slope tends to reduce the delay before smoke or heat reaches the detectors, it is permissible to use a greater spacing between the detectors mounted there.

Fire Alarm Sounders should be installed throughout the building with an even distribution, to generally provide a minimum sound level of 65dB(A) or 5dB(A) above any background noise which is likely to persist for more than 30 seconds.

Limits of Ceiling Height

65dB(A) @ 500Hz - 1000Hz

+5dB(A) @ 500Hz - 1000Hz Background noise

Heat Detector

Smoke Detector

Heat Detector

Smoke Detector

Apex <150mm

Apex <600mm

Apex >150mm

Apex >600mm

Small Apex = Standard Spacing

Large Apex = Extended Spacing

Cabling

Where the alarm may have to arouse sleeping persons e.g. Hotel bedrooms, nursing homes, etc, a minimum sound level of 75dB(A) is required, at the bed head with all the doors shut.

The operation of a Fire Alarm and Detection System’ depends on the cabling and connections between the components. It is essential that connection between Manual Call Points and Detectors function correctly when they are operated. Cables within the system are required to function correctly for significant periods after being attacked by fire. These include the power supply cables to the control panel, the detection circuits and the fire alarm sounder circuits. Thus the cables chosen must be correctly rated to withstand these conditions.

75dB(A)

All fire alarm sounders in a building should produce the same sound, distinct from any other audible warning devices in the building. Where fire alarm sounders are required in extremely noisy areas e.g. Machine shops, it may be necessary to install additional ‘Visual Indication Beacons’.

7


Conventional Fire Alarm Systems /

Premier SX Conventional Fire Alarm Panel (NPSX1, NPSX2, NPSX4, NPSX6, NPSX8)

The Premier SX control panel range is available in 1, 2, 4, 6 and 8 zones, housed in a light grey flame retardant ULV0 enclosure, designed to meet modern architectural surroundings, with a removable hinged door. The Premier SX has been designed with ease of installation in mind, in addition to the robust electronic design expected from Zeta Alarm Systems.

73mm

Features

100mm

LPCB Approved to EN54 parts 2 & 4 One man test facility Disablement facility for zones & sounders Space for up to 7Ahr batteries Sounder delay option (0 – 9 min) Panel can be flush mounted

Flush Mount

8

Wall Mount

Model

NPSX1

NPSX2

NPSX4

NPSX6

NPSX8

Part No.

37-050

37-051

37-052

37-053

37-054

Mains Voltage

230V AC +10% / -15% @ 50/60Hz

System Voltage

24V DC (nominal)

Zone Voltage

21V DC (nominal)

Sounder Alarm Output

2 x 400mA @ 24V DC (nominal)

Fault Relay Output

1 x relay SELV @ 1A maximum

Fire Relay Output

1 x relay SELV @ 1A maximum

Zone Capacity

32 devices per zone

Remote Sounder Activation

Via N/O contact (class change)

Sounder Activation Delay

0-9 minutes in 1 minute increments

Zone End Of Line

IN4002 Diode (cathode stripe to +)

Sounder End Of Line

10K resistor

Charger Voltage

28.4V @ 20°C (with battery disconnected)

Zone Short Circuit Protection

100mA

Charger Short Circuit Protection

Battery voltage less than 20V

Enclosure Size

355 (l) x 275 (h) x 100 (d) mm

Weight

3.25kg (excluding batteries)


Conventional Fire Alarm Systems /

Premier Elite Conventional Fire Alarm Panel (PE1, PE2, PE4, PE6, PE8)

The Premier Elite 1-8 zone fire alarm panels are ideal for small to medium sized installations. They meet all the requirements of EN54 parts 2 & 4, and come in an attractively styled enclosure. The zonal output card gives a drive voltage to operate zonal alarm relays, or a hardwired repeater panel.

Features 73mm

Fault relay (4, 6 & 8 zone only)

100mm

Alarm relay Current limited charger to prevent flat batteries drawing too much current (4, 6 & 8 zone only) Built in diode base compatibility (4, 6 & 8 zone only) Sounder delay facility (4, 6 & 8 zone only) Connection to optional add on zonal output card (4, 6 & 8 zone only) Zone disablement facility (4, 6 & 8 zone only)

Flush Mount

One man test facility (4, 6 & 8 zone only)

Wall Mount

Model

PE1

PE2

PE4

PE6

PE8

Part No.

37-040

37-041

37-042

37-043

37-044

Detection Zones

1

2

4

6

8

Mains Voltage

230V AC +10%/-15% @ 50/60Hz

System Voltage

24V DC (nominal)

Zone Voltage

22V DC (nominal)

Sounder Alarm Output

2 x 400mA @ 24V DC (nominal)

Fault Relay Output

N/A

Fire Relay Output

1 x relay SELV @ 1A maximum

Zone Capacity

20 Devices

32 Devices

Remote Sounder Activation

N/A

Via N/O Contacts

Sounder Activation Delay

N/A

0-9 minutes in 1 minute increments

Zone End Of Line

10K resistor

IN4002 Diode (cathode stripe to +)

Sounder End Of Line

10K resistor

10K resistor

Charger Voltage

27.6V DC (No Batt Connected)

28.4V @ 25째C (No Battery Connected)

Zone Short Circuit Protection

N/A

100mA

Charger Short Circuit Protection

N/A

Batteries less than 21V

Operating Temperature

0째C to 50째C

Enclosure Size

355 x 275 x 100mm

Weight

2.5kg (excluding batteries)

29V DC (nominal)

1 x relay SELV @ 1A maximum

3.25kg (excluding batteries)

9


Conventional Fire Alarm Systems /

Premier Conventional Repeater Panel (PRE-REP)

The Premier Repeater panel is a hard-wired repeater panel for use with the Premier SX (all sizes), and the Premier Elite (4-8 zone) panels. It is display only (no controls) and indicates power, general fault, general fire & the zone in alarm. It also has an internal buzzer to indicate that it requires attention. It comes supplied with an interface card to connect to the Premier SX and Premier Elite (4-8 zone) panels.

73mm

100mm

Features Zonal indication for fire Common fault indication Surface or semi flush fixing

Flush Mount

Model

PRE-REP

Part No.

37-045

Supply Voltage

20–35V DC

Supply Voltage

29V DC (nominal)

Connections

10

Wall Mount

A+

Supply +VE

0V

Supply –VE

GA

General Alarm

CF-

Common Fault

TN-

Tone (Buzzer Active)

Z1- to Z8-

Zonal Alarm

Operating Temperature

-0°C to 50°C

Enclosure Size

355 x 275 x 100mm

Weight

1kg


Conventional Fire Alarm Systems /

Premier M Plus 8-24 Zone Conventional Fire Alarm Panel (PMP8, PMP16, PMP24) The Premier M Plus control panels are designed to fulfil the requirements of EN54 parts 2 & 4 as well as being easy to install, operate and maintain. Being of modular construction, the basic M Plus panel has 8 zone capacity, expandable to 16, 20 and 24 zones. The Premier M Plus is suitable for surface mounting or semi-flush fitting (with just the door protruding).

Features 4 Common sounder circuits (150mA each) Optional add-on zonal sounder circuits (50mA Max.) Serial repeater output Auxiliary supply (29 Volts, 250mA) Zone & sounder disablement facility Sounder delay facility Zonal to common timer (when fitted with zonal sounder boards) One man test mode

Model

PMP8

PMP16

PMP24

Part No.

37-020

37-022

37-024

Detection Zones

8

16

24

Mains Voltage

230V AC +10% / -15% @ 50/60 Hz

System Voltage

24V DC (nominal)

Zone Voltage

21V DC

Sounder Alarm Output

4 x 150mA @ 24V DC

Fault Relay Output

1 x relay SELV @ 1A maximum

Fire Relay Output

1 x relay SELV @ 1A maximum

Zone Capacity

32 Devices

Remote Sounder Activation

N/A

Sounder Activation Delay

0 – 9 minutes in 1 minute increments

Zone End Of Line

IN4002 Diode

Sounder End Of Line

10KΩ Resistor

Charger Voltage

28.4V DC (batteries disconnected)

Zone Short Circuit Protection

100mA

Charger Short Circuit Protection

Batteries less than 20V

Charger Size

3.0 Amp

Operating Temperature

0°C - 50°C

Enclosure Size

485 x 477.5 x 125mm

11


Conventional Fire Alarm Systems /

Premier M Plus Repeater Panel (PMP-REP, PMP-REP/M)

The Premier M Plus repeater is available in 2 versions – standard & multiple. The standard repeater offers display & control functions, however it is limited to one per system. The second version allows multiple repeaters on the same system however they do not have any control functions (i.e. they cannot be used to silence or reset the system). A single repeater can be powered from the panels’ auxiliary 24V supply. If more than one repeater is to be used, a separate 24V is required.

Model

PMP-REP

PMP-REP/M

Part No.

37-026

37-027

Functions

Display & control

Control only

Supply Voltage

20-30V DC

Max. Quantity Per System

1 Serial Repeater A

Connections

Serial Repeater B +24V DC 0V

12

Operating Temperature

0°C to 50°C

Enclosure Size

375 x 335 x 125mm

Weight

TBC

5


Conventional Fire Alarm Systems /

Premier 48 M Plus 24-48 Zone Conventional Fire Alarm Panel (PMP48/24, PMP48/32, PMP48/40, PMP48/48) The Premier 48 M Plus control panels are designed to fulfil the requirements of EN54 parts 2 & 4 as well as being easy to install, operate & maintain. Being of modular design, the basic panel has 24 zones built in and it can be expanded to 32, 40 & 48 zones. The construction of the panel is epoxy painted steel enclosure, with top & rear cable entries.

Features 4 common sounder circuits (400mA each) Optional add-on zonal sounder circuits (50mA Max) Serial repeater output Auxiliary supply (29 Volts, 250mA) Zone & sounder disablement facility Sounder delay facility Zonal to common timer (when fitted with zonal sounder boards) One man test mode Model

PMP48/24

PMP48/32

PMP48/40

PMP48/48

Part No.

37-030

37-032

37-034

37-036

Detection Zones

24

32

40

48

Supply Voltage

230V AC +10%/-15% @ 50/60 Hz

System Voltage

29V DC (nominal)

Zone Voltage

21V DC

Sounder Alarm Output

4 X 400mA @ 24V DC

Fault Relay Output

1 relay SELV @ 1A (normally energised)

Fire Relay Output

1 relay SELV @ 1A maximum

Other Connections

Class Change Input (N/O Contact) / F.A.R.E. Output / Serial Repeater Output (4 Wire)

Zone Capacity

Up to 32 devices

Remote Sounder Activation

N/A

Sounder Activation Delay

0 to 9 minutes

Zone End Of Line

100μF capacitor

Sounder End Of Line

10K resistor

Charger Voltage

28.4V DC (Batteries disconnected)

Zone Short Circuit Protection

100mA

Charger Short Circuit Protection

Batteries less than 20V

Charger Size

3 Amp

IP Rating

IP43

Operating Temperature

0°C to 50°C

Enclosure Size

675 x 480 x 135mm

Weight

13kg

13


Conventional Fire Alarm Systems /

Premier 48 M Plus Repeater Panel (PMP48-REP, PMP48-REP/M)

The Premier 48 M Plus repeater is available in 2 versions – standard & multiple. The standard repeater offers display & control functions, however is limited to one per system. The second version allows multiple repeaters on the same system however they do not have any control functions (i.e. they cannot be used to silence or reset the system). A single repeater can be powered from the panels’ auxiliary 24V supply. If more than one repeater is to be used, a separate 24V is required.

Model

PMP48-REP

PMP48-REP/M

Part No.

37-037

37-038

Functions

Display & control

Control only

Supply Voltage

20–30V DC

Maximum Quantity Per System

1 Serial Repeater A

Connections

Serial Repeater A +24V DC 0V

14

Operating Temperature

0°C to 50°C

Enclosure Size

480 x 330 x 60mm

Weight

4.8kg

5


Conventional Fire Alarm Systems /

Premier MX Conventional Fire Alarm Panel (MX-16 & MX-32)

The Premier MX ranges of panels are available in either 16 or 32 zone versions and have been approved by LPCB to EN54 parts 2 & 4. The panels offer an extensive range of configuration options whilst remaining easy to install and configure.

Model

MX-16

MX-32

Part No.

37-140

37-142

Detection Zones

16

32

Supply Voltage

230V AC +/- 10%

Zonal one-man test facility

System Voltage

24V DC (Nominal)

Zone Voltage

24V DC (Nominal) Relay, SELV @ 1A

Latching or non-latching zones

Zone End of Line

22uF, 35V Axial Capacitor

Sounder Output

4 X 1.0A @ 24V DC

Sounder EOL

3K9 Resistor

Aux DC Output

24V DC (Nominal) 1A

Repeater option

Yes Remote Evacuation Remote Silence Alarms

Panel Inputs

Remote Reset Class Change Panel Outputs Fault Routing Relay, SELV @ 1A Fire Routing Relay, SELV @ 1A

Features LPCB Approved to EN54 parts 2 & 4

Delayed or non delayed zone operation Standard or intrinsically safe zone mode Short circuit to fire mode for compatibility with old detectors

Fire Protection Relay, SELV @ 1A Disablement Active (Open Collector Output) Evacuation Active (Open Collector Output) Buzzer Active (Open Collector Output)

Zonal or common alarm operation (requires output expansion PCBs) Latching or non-latching fault modes Fault routing, fire routing & fire protection relays can be programmed as 24V output (monitored) or volt free Fault routing, fire routing & fire protection relays can have delayed operation in any configuration The panel is available as flush mount on request Repeater panel option (up to 5 maximum per panel)

RS 485 Repeater Connection

Operating Temperature

-5째C to 40째C

Size

325 x 370 x 126mm 400 x 441 x 131mm

Weight

7.05kg

9.35kg

15


Conventional Fire Alarm Systems /

Fyreye Extra Conventional Optical Smoke Detector (FEOE2000) The Fyreye Extra optical smoke detector uses a pulsing IR LED & photodiode to detect IR scatter caused by smoke entering the chamber. The detector is particularly suitable for detecting optically dense smoke, involving materials such as soft furnishings, PVC, plastic, foam and all similar materials which produce small visible particles (0.5 to 10μm). The detector will work with most modern fire alarm control panels and comes supplied with a locking grub screw to prevent unauthorised head removal. The Fyreye Extra range of detectors has an extra LED to improve detector identification in an alarm condition.

100mm

37mm

Features Designed to meet EN54 requirements Attractive design Dual LEDs for 360° visibility Lockable base to stop unauthorised removal Compatible with all Fyreye bases

16

Model

FEOE2000

Part No.

80-022

Detector Class

Optical Smoke

Design Standard

EN54 part 7

Approval

DIFT

Operating Voltage

9-33V DC

Quiescent Current

65μA

Alarm Current @ 24V DC

53mA MAX

Operating Temperature

-10°C to +50°C

Minimum Continuous Temperature

0°C

Maximum Humidity

95% RH non-condensing

Alarm Condition

2.4% obscuration per metre

Coverage

100m2

IP Rating

IP43

Start-up Time

10 Seconds

Size (with Base)

100 x 37mm (101 x 53mm)

Weight (with Base)

95g (153g)


Conventional Fire Alarm Systems /

Fyreye Extra Conventional Rate of Rise and Fixed Heat Detectors (FEHE2000 & FEFHE2000) The Fyreye Rate of Rise heat detector (FEHE2000) uses a thermistor arrangement to sense a quick rise in temperature and also a final threshold temperature of 57°C. The Fyreye fixed heat detector (FEFHE2000) has a single thermistor arrangement that gives an alarm at a temperature of 90°C. The detectors will work with most modern fire alarm control panels and comes supplied with a locking grub screw to prevent unauthorised head removal. The Fyreye Extra range of detectors has an extra LED to improve detector identification in an alarm condition.

100mm

48mm

Features Designed to meet EN54 requirement Lockable to base to stop unauthorised removal Remote LED output Dual LEDs for 360° visibility Compatible with all Fyreye bases

Model

FEHE2000

FEFHE2000

Part No.

80-038

80-039

Detector Class

Rate of Rise & Fixed Heat Detector

Fixed Heat Only

Design Standard

EN54 part 5

Approval

DIFT

Operating Voltage

9-33V DC

Quiescent Current

40μA

Alarm Current @ 24V DC

34mA

Operating Temperature

-10°C to +50°C

Minimum Continuous Temperature

0°C

Maximum Humidity

95% RH non-condensing

Alarm Condition

Rate of rise or fixed heat trigger @ 57°C

Coverage

50m²

IP Rating

IP43

Start-up Time

10 Seconds

Size (with Base)

100 x 48 mm (101 x 64 mm)

Weight (with Base)

75g (133g)

Fixed heat trigger @90°C

17


Conventional Fire Alarm Systems /

Fyreye Extra Conventional Opto-Heat Detector (FEOH2000) The Fyreye Extra opto-heat detector incorporates both an optical chamber and heat sensing element with advanced detection technology & discrimination algorithms. This multisensor is the perfect replacement for ionisation detectors. The detector will work with most modern fire alarm control panels and comes supplied with a locking grub screw to prevent unauthorised head removal. The Fyreye Extra range of detectors has an extra LED to improve detector identification in an alarm condition.

Features 100mm

50mm

Advanced electronic technology used to minimise false alarms Designed to meet EN54 requirement Built-in 10 seconds alarm verification Lockable to base to stop unauthorised removal Remote LED output Dual LEDs for 360° visibility Compatible with all Fyreye bases

18

Model

FEOH2000

Part No.

80-025

Detector Class

Optical / Heat

Design Standard

EN54

Approval

DIFT

Operating Voltage

17-20V DC

Quiescent Current

100μA

Alarm Current @ 24V DC

70mA MAX

Operating Temperature

-20°C to +60°C

Minimum Continuous Temperature

0°C

Maximum Humidity

95% RH non-condensing

Alarm Condition

3% obscuration per metre

Coverage

100m²

IP Rating

IP43

Start-up Time

10 Seconds

Size (with Base)

100 x 50mm (100 x 66mm)

Weight (with Base)

95g (153g)


Conventional Fire Alarm Systems /

Fyreye Conventional Ultra-Violet Flame Detector

(FEUV2000)

The Fyreye ultra-violet flam detector is particularly suited to applications where flames can be expected to develop initially rather than smoke. This is typically due to the nature of the materials being protected for instance camera film, computer, audio & video tapes or disks. The detector is for indoor use only and should not be exposed to spurious sources of UV, such as sparks, uncovered halogen lights, lightening, etc. as these may trigger a false alarm. Due to the operational nature of flame detectors it is generally recommended to fit just one detector per zone.

Features

0° 30°

30°

60°

60°

90°

90° ANODE CATHODE

UV EMISSION POINT

0° 30°

Low profile shape

VERTICAL VIEWING (top fig.)

The detector is solar blind and incorporates an electronic filter to eliminate unwanted alarms from naturally occurring phenomena

HORIZONTAL VIEWING (bottom fig.)

Fast response time

30°

60°

High immunity to electrical noise & RF interference

60°

90°

90° ANODE CATHODE

Horizontal & Vertical Detector Field Of View

Model

FEUV2000

Part No.

80-045

Detector Class

Ultra Violet Flame Detector

Operating Voltage

12-28V DC

Quiescent Current

320μA

Alarm Current @ 24V DC

45-50mA

Operating Temperature

0°C to 45°C

Minimum Continuous Temperature

0°C

Maximum Humidity

95% RH non-condensing

Alarm Condition

10 seconds for 30mm flame @ 4 metres

Detection Angle

120°

UV Sensitivity

185-260nm

Size (with Base)

98 x 36mm (98 x 52mm)

Weight (with Base)

85g (143g)

19


Conventional Fire Alarm Systems /

Fyreye Conventional Detector Bases (FE-CB, FE-DB, FE-RB)

FE-CB

FE-CB/S

There are 3 types of base available for the Fyreye conventional range of detectors namely common base, diode base and relay base. The Fyreye common base and diode base are available in standard, shallow or deep versions. The common base is used on systems that do not need to keep line integrity on head removal and also on addressable systems.

20

FE-CB/D

The diode base is used on systems that do need line integrity on head removal. This would include all conventional systems that mix detectors & call points on the same line (please note that the Premier M Plus panels will need an active end of line to work with diode bases). The relay base is mainly used on 12V security systems to signal detector operation to the panel. They can

FE-RB

FE-DB

also be used on 24V fire systems where the activation of a particular detector requires a signal to nearby equipment (for instance door holders). Please note that a remote led indicator cannot be used with a relay base as the detector cannot sink enough current to operate both.

Model

FE-CB

FE-CB/S

FE-CB/D

FE-DB

FE-DB/S

FE-DB/D

FE-RB

Part No.

80-050

80-050S

80-050D

80-052

80-052S

80-052D

80-054

Type

Common base

Supply Voltage

9-33V DC

Quiescent Current @ 24V

0μA

Alarm Current @ 24V

0mA

15mA

Relay Max Switching Power

N/A

30W, 50VA

Relay Max Switching Power

N/A

30W, 50VA

Diode base

Relay base 24V DC

Relay Max Switching Current N/A

1A resistive

Relay Max Switching Voltage N/A

50V AC

Relay Minimum Capability

N/A

10μA, 10mV

Relay Dropout Voltage

N/A

<6V

Operating Temperature

-20°C to 90°C (non-condensing or icing)

Max. Wind Speed

Not affected

Connections

L1in, L1out, L2, -R & Earth

Size

100 x 15mm 100 x 8mm

100 x 25mm 100 x 15mm 100 x 8mm

100 x 25mm 100 x 15mm

Weight

48g

61g

61.2g

42g

48.2g

42.2g

171.4g


Conventional Fire Alarm Systems /

Zeta Remote LED Indicator (ZT-RL)

Remote LEDs indicators are used in installations where a detector going to alarm is likely to occur out of sight (for instance behind a locked door or in a ceiling void). In these instances the indicator will then show the location of the alarm.

Features Twin LED’s Surface or flush mounting

Model

ZT-RL

Part No.

48-023

Input Voltage

5 – 30vdc

Quiescent Current

0mA

Alarm Current

12mA

Operating Temperature

0°C - 50°C

Max Humidity

95% Relative Humidity Non-condensing

IP Rating

IP41

Size

85 x 85 x 70mm

Weight

113g

21


Conventional Fire Alarm Systems /

Fyreye 50 & 100m Reflective Beam Smoke Detector (ZT-50RZ, ZT-100RZ, ZT-50RV & ZT-100RV)

The Fyreye reflective beam detectors comprise of a single unit incorporating an infrared transmitter & receiver. The signal is reflected by a prism and analysed for smoke presence. Should a predetermined level be reached then the detector will signal an alarm. The system is designed to be mounted so that the beam will project between 0.3 and 0.6 metres below the ceiling and parallel to it. Lateral detection may be up to 7.5 metres either side of the beam.

Features

70mm 126mm

120mm

50 or 100 metre reflective beam smoke detector VdS approved BS 5839 part 5

100mm 100mm

140mm 210mm

Complies fully to; EN54 part 12 Single compact housing Horizontal or vertical mounting 12-24V DC operation 9.5mm

Low current consumption Latching or non latching alarm Reflector targeting mode to ease set-up Microprocessor controlled Automatic contamination compensation Selectable sensitivity Robust construction

22


The Fyreye beam detectors are available with ranges of up to 50 or 100 metres and either 2 or 4 wire connections.

The 2 wire models (ZT-50RZ & ZT-100RZ) are zone powered (please note these will only work on Premier SX & M Plus panels).

The 4 wire models (ZT-50RV & ZT-100RV) require an external 24V power supply and have a fire & fault relay output for wide compatibility.

Typical Applications Beam detectors are generally used for two purposes; either to cover a wide-open space and/or in places where several regular smoke detectors would be aesthetically unacceptable. Such places include; Shopping centres

Open Plan offices

Heritage sites

Warehouses

Churches or mosques

Factories

Museums

Power stations

Leisure centres

and more

Model

ZT-50RZ

ZT-100RZ

ZT-50RV

ZT-100RV

Part No.

47-050

47-051

47-050A

47-051A

Range

5-50m

50-100m

5-50m

50-100m

Number of Wires

2

Supply Voltage

10.2V to 30V DC

Quiescent Current

<4mA

Operating Temperature

-30°C to 55°C

Max Humidity

95% RH non-condensing

Max Wind Speed

Not affected

Alarm Current

35mA (typical)

<15mA

Fire Output

470 OHM resistor placed across zone internally

Fire relay closing (relay contact is normally open)

Fault Output

Schottky diode introduced between –VE in & -VE out

Fault relay opening (relay contact is normally closed)

Power Down Reset

<2 seconds

>5 seconds

4

Beam Misalignment Tolerance Detector ± 0.8° at 35% Prism ± 5.0° Alarm Thresholds

2.50dB (25%), 3.74dB (35%), 6.02dB (50%)

Optical Wavelength

880nm

Construction

Flame Retardant ABS (Grey /Black)

IP Rating

IP50

Size

130 x 210 x 120mm

Weight

0.75kg

0.7kg

23


Conventional Fire Alarm Systems /

Fyreye 50 & 100m Auto-aligning Beam Smoke Detector Systems 50 & 100m (ZT-5000R & ZT-5000R/100)

Based on the proven technology of the standard Fyreye reflective beam detectors, the Fyreye auto-aligning beam detector has been designed to help improve ease of installation. The system is ideally suited for the protection of large areas where the use of traditional detection technologies would prove to be too difficult and/or costly to install. The system combines an infrared transmitter and receiver in the same discrete unit and operates by projecting a well-defined beam to a reflective prism, which returns the beam to the receiver for analysis. Smoke in the beam path causes a drop in power, which, if below a pre-determined level, results in an alarm signal.

The system consists of 2 parts; the beam detector itself and a low level control unit. The system can be fully customised, according to local conditions and installation guidelines; alarm thresholds (sensitivity) and time to alarm/fault can be set from the low level system controller. Each detector head is independently configurable from 8m through to 100m and has its own individual fire threshold. The system controller retains one set of fire and fault relays that is common to all detectors that are installed. The system is supplied as either a 50 or 100 metre version with a single detector head. Additional heads and a long range kit (additional prisms to allow the detector head to reach 100m) are available separately.

Additional System Components ZT-5000R/DH - 47-072 - Fyreye Auto-aligning Single Beam Detector Head 50m ZT-5000R/100/DH - 47-073 - Fyreye Auto-aligning Single Beam Detector Head 100m ZT-5000R/LRK - 47-074 - Fyreye Auto-aligning Beam Detector Long Range Kit

24

Features Worldwide approvals including EN54:12 and UL268 Up to 4 detectors per system controller Each detector configurable from 8m to 100m Integral LASER Auto-align fast automatic beam alignment Auto-optimise building movement and contamination compensation Low level system controller 20mm cable gland knockouts on system controller 2-wire interface from system controller to detector


202mm 135mm

81mm

135mm

230mm

135mm

Model

ZT-5000R

ZT-5000R/100

Part No.

47-070

47-071

Range

50m

100m

Number of Wires

4

Supply Voltage

14-28V DC

Operating Current

8-12mA (low current mode with 1 detector) 48-52mA (high current mode with 1-4 detectors)

Operating Temperature

-20°C to 55°C

Storage Temperature

-40°C to 85°C

Max Humidity

85% RH non-condensing

Max Wind Speed

Not affected

Alarm Current

35mA (typical)

Fire Output

Volt free relay contact

Fault Output

Volt free relay contact

Beam Misalignment Tolerance @ 35%

Detector ± 0.8°, Prism ± 5.0°

Alarm Thresholds

2.50dB (25%), 3.74dB (35%) & 6.02dB (50%)

Optical Wavelengths

850nm

Construction

Flame Retardant ABS (Grey / Black)

IP Rating

IP54

Detector Size

135 x 135 x 135mm

Detector Weight

0.5kg

Controller Size

202 x 230 x 81mm

Controller Weight

0.9kg

25


Conventional Fire Alarm Systems /

Zeta UV/IR Optical Flame Detectors (VS-200P & VS-200EX)

VS-200P

VS-200EX

The VS-200P & VS-200EX UV/IR flame detectors detect fuel & gas fires at long distances with the highest immunity to false alarms. The detectors can detect a 0.1m² gasoline pan fire at 30m in less than 5 seconds.

Typical Applications Non-hazardous (VS-200P) Parking buildings Warehouse Waste disposal facilities Culture centres

Hazardous (VS-200EX) Offshore oil & gas installations Onshore oil & gas installations and pipelines Petrochemical plants Chemical plants Shipbuilding facility Automotive industry Storage tank farms Power generation facility Petrochemical plants Painting industry Warehouse Waste disposal facility Explosive & munitions

26

Features UV/IR spectrum for medium distance detection and high false alarm immunity Compact & lighter design User selectable sensitivity & functions Multiple output options (relays for alarm & fault, 0-20mA (stepped) and RS-485/RS-232 spectrum monitoring) ATEX approved by DNV for explosion-proof (VS200EX UV/IR only) CE certified


Model

VS-200P

VS-200EX

Part No.

47-150

47-151

Spectrum Response

UV /IR (Dual Bands)

Spectrum Response (at highest sensitivity setting for 0.1m² pan fire)

Fuel n-Heptane Gasoline Diesel LPG*

Distance 30m 30m 20m 20m

Fuel Ethanol IPA Methanol

Distance 20m 25m 20m

*0.5m high / 0.2m width plume fire Response Time

Typically 5 seconds

Adjustable Time Delay

Up to 20 seconds

Sensitivity Range

4 sensitivity ranges for 0.1m² n-Heptane pan fire from 15m to 65m

Field of View

Horizontal 90°, Vertical 90°

Built-in-Test

Manual (optionally Automatic)

Temperature Range

Operating/Storage: -40°C to 75°C

Humidity

Up to 95% non-condensing

Operating Voltage

24VDC norminal (17-31VDC)

Power Consumption

Standby: max. 35mA, Alarm: max. 75mA

Cable Entry

1 x M20 (ISO)

Wiring

AWG 16-26 (Str 1.5mm² to 0.13mm²)

Electromagnetic Compatibility

EMI/RFI protected to EN61000 series

Electrical Interface

The detector includes twelve(12) terminals with four(4) wiring options

Relays

Alarm, Fault. SPST volt-free contacts rated 5A at 30VDC or 250VAC Non-isolated “Source” configuration

0-20mA (stepped)

Fault: Normal: Alarm:

0 +1mA 4mA±10% 20mA±10%

Materials

Polycarbonate Enclosure

Bit Fault: Warning: Resistance Loop:

2mA±10% 16mA±10% Max. 800Ω

Heavy duty copper free aluminium (less than 1%) with bright grey anodizing finish Enclosure options - Stainless Steel 316L with electro polish finish

Mounting (Tilt Mount)

Stainless Steel

Heavy duty copper free aluminium (less than 1%) with grey epoxy enamel finish Options - Stainless Steel 316L with electro polish finish

Dimensions

Detector: 80 x 82 X 86 mm

Weight

Detector : 0.3kg (1.0kg with cable gland / 1m-length cable / Tilt Mount)

Water and Dust

IP66 per EN60529

EMI/RFI

CE Marking

Performance

EN54-10 (designed to meet)

Detector: 83(d) x 126(l) mm Detector (aluminium): 1.1 kg (1.4 kg with Ex cable gland / 1m-length Detector (St. SUS316L): 2.0 kg Tilt mount (aluminium/ St.): 0.3kg / 0.7kg IP66 and IP67 per EN60529 ATEX Ex II 2 G Exd IIC T6, -40°C to +75°C (DNV 09 ATEX 0000) KFI (Korea) EN54-10 (designed to meet)

27


Conventional Fire Alarm Systems /

Zeta Conventional Manual Call Points (ZT-CP2, ZT-CP2/W, ZT-CP1 & ZT-CP1/W)

The Zeta conventional manual call point has a modern design and has been approved by BSI to EN54 part 11. It is a resettable call point that signals an alarm with a yellow flag entering the window area and a red alarm LED. There are two versions available; the ZT-CP2 call points comes complete with a protective Perspex cover as well as a “snaplatch” catch that needs to be broken off before the call point cover can be lifted (this acts as a deterrent to malicious activations and forms a Type B call point). Alternatively the ZT-CP1 is supplied without the Perspex cover & “snaplatch” and is single action or Type A call point. The recommended colour for these call points is red however white is also available to meet architectural requirements.

Features BSI approved to EN54 part 11 Attractive design

28

Model

ZT-CP2

ZT-CP2/W

ZT-CP1

ZT-CP1/W

Part No.

43-300

43-314

43-301

43-317

Type

Type B

Element Type

Resettable

Alarm Activation

Break “snaplatch”, lift Perspex cover, press element

Press element

Colour

Red

Red

Input Voltage

9-33V DC

Quiescent Current

0mA

Alarm Current

Typical 35mA (maximum 51mA)

Alarm Load

470 Ω resistor

Operating Temperature

-20°C to 50°C

Max Humidity

95% RH non-condensing

IP Rating

IP43

Size

111 x 100 x 67mm

105 x 100 x 58mm

Weight

198g

175g

Type A

White

White


Conventional Fire Alarm Systems /

Zeta Conventional Weatherproof Call Point (ZT-CP2/WP)

The Zeta conventional weatherproof manual call point is an IP65 rated call point which complies with EN54 part 11. It is resettable and signals an alarm with a yellow flag entering the window area and a red alarm LED. The call point comes complete with a protective Perspex cover as well as a “snaplatch” catch that needs to be broken off before the call point cover can be lifted (this acts as a deterrent to malicious activations and forms a Type B call point).

Features Complies with EN54 part 11 Attractive design Resettable element Protective cover

Model

ZT-CP2/WP

Part No.

43-350

Type

Type B

Element Type

Resettable

Alarm Activation

Break “snaplatch”, lift Perspex cover, press element

Colour

Red

Input Voltage

9-33V DC

Quiescent Current

0mA

Alarm Current

Typical 35mA (maximum 51mA)

Alarm Load

470 Ω resistor

Operating Temperature

-20°C to 50°C

Max Humidity

95% RH non-condensing

IP Rating

IP65

Size

87 x 87 x 70mm

Weight

198g

29


Conventional Fire Alarm Systems /

Zeta Conventional Explosion Proof Manual Call Point (ZT-BGU/WP/R & ZT-BGU/WP)

The Zeta conventional explosion proof manual call point is manufactured from aluminium with a built-in push button activator. The call point is finished with red anti-corrosive epoxy powder coating with 2 x 20mm cable entries. This unit is equipped with a stainless steel hammer and chain. Two models are available; the ZT-BGU/WP/R with 470Ω built-in resistor for connection to a standard fire alarm system or the ZTBGU/WP for mains connection.

4 Holes - ø7

I

F

N

CASE O FIRE S

BR

E

AK

GL

105mm

2 Nos.0.75″ET

30

Hammer S

185mm

A

Chain

Model

ZT-BGU/WP/R

ZT-BGU/WP

Part No.

43-300/WP

43-305/WP

Contact Rating

10 Amp

Voltage Rating

500V AV

Build-in Resistor

470Ω

IP Rating

IP65

Earthling

2No M6 eternal & 1No M5 internal

Size

TBC

Weight

1.5kg

N/A


Conventional Fire Alarm Systems /

Miditone Conventional Electronic Sounder (ZMDD/8R & ZMDD/8W)

The Miditone sounder is a small, high output conventional sounder which designed to meet the requirements of EN54 part 3 and is CE marked. The sounder is a compact unit that fits a standard European back box and can be either surface or flush mounted. It has a choice of 8 tone patterns, selectable by an internal dip switch and a sound output of 95dB @ 1m with volume control. It is available in red or white to meet architectural requirements.

Features Complies to EN54 part 3 95dB @ 1m sound output 8 Tone patterns Flush or surface fixing

Model

ZMDD/8R

ZMDD/8W

Part No.

42-040

42-040A

Sound Output

See current consumption table

Colour

Red

Operating Voltage

9-30V DC

Quiescent Current

0mA

Alarm Current @ 24V

See current consumption table

Operating Temperature

-10째C to 50째C

Minimum Continuous Temperature

0째C

Maximum Humidity

95% RH Non Condensing

IP Rating

IP43

Size (with Back Box)

85 x 85 x 35mm (85 x 85 x 67mm)

Weight (with Back Box)

100g (150g)

White

DIL Switch Settings (SW4 N/A) 1

2

3

Tone Description

dB Level

Current (mA)

Off

Off

Off

Sweep Negative 1200- 500 Hz In 1 Second

97 (+/- 2dB)

21

On

Off

Off

Alternating 554 and 440Hz 0.5s Each

95 (+/- 2dB)

17

Off

On

Off

Continuous 660Hz

96 (+/- 2dB)

22

On

On

Off

Alternating 554Hz @ 0.1s/440Hz @ 0.4s

94 (+/- 2dB)

17

Off

Off

On

Intermittent 970Hz @ 0.5s On/Off

93 (+/- 2dB)

8-24

On

Off

On

Continuous 970Hz

95 (+/- 2dB)

25.5

Off

On

On

Sweep Positive 800-970Hz

99 (+/- 2dB)

25

On

On

On

Alternating 800 and 970Hz @ 0.25s Each

100 (+/- 2dB)

25

31


Conventional Fire Alarm Systems /

Miditone Conventional Combined Electronic Sounder & Flasher (ZMDF/8R, ZMDF/8A, ZMDF/8B, ZMDF/8C & ZMDF/8G) The Miditone combined sounder & flasher is a small, high output conventional sounder & flasher which is designed to meet the requirements of EN54 part 3 and is CE marked. The device is a compact unit that fits a standard European back box and can be either surface or flush mounted. It has a choice of 8 tone patterns, selectable by an internal dip switch and a sound output of 95dB @ 1m with volume control. This is an ideal solution to upgrade an existing sounder to a combined sounder & flasher. It is available with either a red, amber, blue, clear or green lens to meet architectural requirements.

Features Complies to EN54 part 3 95dB @ 1m sound output 8 tone patterns Flush or surface fixing Model

ZMDF/8R

ZMDF/8A

ZMDF/8B

ZMDF/8C

ZMDF/8G

Part No.

42-024

42-024A

42-024B

42-02C

42-024G

Sound Output

See current consumption table

Lens Colour

Red

Blue

Clear

Green

Operating Voltage

17-30V DC

Quiescent Current

0mA

Alarm Current @ 24V

See current consumption table

Operating Temperature

-10째C to 50째C

Minimum Continuous Temperature

0째C

Maximum Humidity

95% RH non condensing

IP Rating

IP43

Size (with Back Box)

85 x 85 x 35mm (85 x 85 x 67mm)

Weight (with Back Box)

112g (162g)

Amber

DIL Switch Settings (SW4 N/A)

32

1

2

3

Tone Description

dB LEVEL

CURRENT (mA)

Off

Off

Off

Sweep Negative 1200- 500 Hz In 1 Second

102 (+/- 2dB)

35

On

Off

Off

Alternating 554 and 440Hz 0.5s Each

100 (+/- 2dB)

27

Off

On

Off

Continuous 660Hz

100 (+/- 2dB)

33

On

On

Off

Alternating 554Hz @ 0.1s/440Hz @ 0.4s

98 (+/- 2dB)

26

Off

Off

On

Intermittent 970Hz @ 0.5s On/Off

93 (+/- 2dB)

13 - 35

On

Off

On

Continuous 970Hz

103 (+/- 2dB)

37

Off

On

On

Sweep Positive 800-970Hz

103 (+/- 2dB)

45

On

On

On

Alternating 800 and 970Hz @ 0.25s Each

103 (+/- 2dB)

42


Conventional Fire Alarm Systems /

Securetone Conventional Electronic Sounder (ZST/8R & ZST/8W)

The Securetone sounder is designed to be aesthetically pleasing and unobtrusive. It has an elegant round design and fits to its supplied mounting plate with a bayonet action to avoid unsightly screws. It has 8 selectable tones with a volume adjust screw to set the required sound level. This product is designed to meet the requirements of EN54 part 3 and is CE marked.

Features 85mm

8 selectable tones Volume control

100mm

Model

ZST/8R

ZST/8W

Part No.

42-004

42-004A

Sound Output

100dBA @ 1 metre

Colour

Red

Operating Voltage

10-30V DC

Quiescent Current

0mA

Alarm Current @ 24V

35mA MAX

Operating Temperature

-0째C to 50째C

Minimum Continuous Temperature

0째C

Maximum Humidity

95% RH Non Condensing

IP Rating

IP43

Size (including Plate)

100 x 100 x 75mm (100 x 100 x 85mm)

Weight (including Plate)

230g (260g)

White

33


Conventional Fire Alarm Systems /

Secure Light Xenon Flasher (ZTSL6/R & ZTSL6/A)

The Secure Light Xenon Flasher range is designed to provide a visual warning at alarm condition. Both red and amber versions are available with the lenses constructed of high-Impact and heat resistant ACRYREX. The case is made of high-impact resistant ABS plastic.

Features

97mm

Available in Red & Amber Fits onto a standard outlet box 100mm

34

Model

ZST/8R

ZST/8W

Part No.

42-035

42-038

Colour

Red

Amber

Flash Energy

3 Watt

Flash Frequency

60 times per minute

Operating Voltage

20-30V DC

Quiescent Current

0mA

Alarm Current @ 24V

100mA MAX

Operating Temperature

-30째C to 60째C

Minimum Continuous Temperature

0째C

Maximum Humidity

95% RH Non Condensing

IP Rating

IP54

Size

97 x 100mm

Weight (including Plate)

231g


Conventional Fire Alarm Systems /

Maxitone Conventional Sounder and Combined Sounder & Flasher (ZMT/8R, ZMT/8W & ZMTF/8R) The Maxitone sounder is an ideal alternative to fire bells and for external use. It is housed in an attractive horn comprises of flame retardant ABS. Eight selectable tones and volume control are featured to meet most requirements. The Maxitone is also available with transparent polycarbonate front which will provide both visual and audible alarm.

Features

120mm

High output 8 selectable tones Volume control 126mm

107mm

Model

ZMT/8R

ZMT/8W

ZMTF/8R

Part No.

42-001

42-001A

42-032

Sound Output

See current consumption table

Colour

Red

Operating Voltage

17-30V DC

Quiescent Current

DIL SWITCH SETTINGS (SW4 N/A) 1

2

3

Tone Description

dB Level

Current (mA)

Off

Off

Off

Sweep Negative 1200500 Hz In 1 Second

101 (+/2dB)

27

0mA

On

Off

Off

Alternating 554 and 440Hz 0.5s Each

98 (+/2dB)

20

Alarm Current @ 24V

See current consumption table

Off

On

Off

Continuous 660Hz

101 (+/2dB)

27

Operating Temperature

-20째C to 60째C

On

On

Off

Alternating 554Hz @ 0.1s/440Hz @ 0.4s

98 (+/2dB)

19

Minimum Continuous Temperature

0째C

Off

Off

On

Intermittent 970Hz @ 0.5s On/Off

98 (+/2dB)

20

On

Off

On

Continuous 970Hz

103 (+/2dB)

29.3

Off

On

On

Sweep Positive 800970Hz

103 (+/2dB)

38

On

On

On

Alternating 800 and 970Hz @ 0.25s Each

102 (+/2dB)

35

White

Maximum Humidity 95% RH non condensing IP Rating

IP65

Size

124 x 130 x 100mm

Weight

357g

Red

35


Conventional Fire Alarm Systems /

Zeta Conventional Fire Alarm Bells (ZTB6B, ZTB8B/230, ZTB8B & ZTB8B/WP)

ZTB8B

ZTB6B

55mm

152mm

152mm

The Zeta motorised fire alarm bells combine styling and functional efficiency. They incorporate a low power rotary centrifugal mechanism, which gives a high sound output with low current consumption at 24V dc. The bells are available in 2 sizes; 6″ (152mm) and 8″ (203mm). These sizes suit a wide variety of installations.

55mm

203mm

203mm

There is a 230V ac version of the 6″ bell, and a 24V dc Weatherproof version of the 8″ bell.

Features Low current Universally accepted fire evacuation signal

36

Model

ZTB6B

ZTB8B/230

ZTB8B

ZTB8B/WP

Part No.

41-003

41-004

41-005

41-006

Supply Voltage

18-30V dc

200-250V AC

18-30V dc

Diameter

6″ (152mm)

8″ (203mm)

Quiescent Current

25mA

28mA

Nominal Output @ 1M

95dB(A)

97dB(A)

Dimensions

152 x 152 x 55mm

203 x 203 x 55mm

Weight

860g

960g

1700g

1800g


Conventional Fire Alarm Systems /

Zeta Flame Proof Siren (ZTSR/EXD24 & ZTSR/EXD230)

The Zeta flame proof siren is an explosion proof siren available in either 24V or 230V versions. An intrinsically safe circuit is housed in the main chamber and it is duly wired up to terminal chamber through sealed bushes. The horn unit is placed on the main chamber cover and the output signals are taken through sealed coils. Neoprene ‘0’ rings are provided for the weather proof protection.

170mm

240mm

390mm

Model

ZTSR/EXD24

ZTSR EXD230

Part No.

42-100/24

42-105/230

Type Of Protection

Flame proof – Exd T6 IP 65

Area Classification

Zone 1 & 2

Gas Groups

Group I, II A, II B, II C

Apparatus Standard

IS - 2148

CMRI Certificate

CMRI / TC / S / H388

Approvals

CCE, DGFAS

Materials

Cast Aluminium LM 6

Weight

5 Kg (approx.)

Size

170 (w) x 390 (h) x 240 (d) mm

IP Protection

IP 65 to IS 13947 / 93

Finish

Anti corrosive Epoxy – Powder Coated

Cable Entry

2 x ¾″ ET

Gasket

Neoprene

Hardware

Stainless Steel

Terminals

4 x 2.5 sq. mm (standard) 6 x 2.5 sq. mm (for looping)

Voltage

24 V DC

Output Current

600mA Peak. Galvanically Isolated

Power Rating

18 Watts

Sound Output

106 db 900 Hz On & Off alternatively at 1C/s

Earthing

External: 2 Nos. - M6

230 V AC – 50 Hz

Internal: 1 No. M5

37


Conventional Fire Alarm Systems /

Zeta Flame Proof Gong Bell (ZTB8B/EXD/24)

The Zeta flame proof gong bell is an explosion proof gong bell with a terminal chamber. A highly reliable electric circuit is housed inside to control the frequency of the gong operating spindle. The operating spindle and dish are made out of stainless steel thereby ensuring a long life. The electric circuits are connected to terminals in the terminal chamber through nipple. The covers are provided with neoprene gaskets for weatherproof protection.

225mm

160mm

285mm

38

Model

ZTB8B/EXD

Part No.

41-075

Type Of Protection

Flame proof – Exd T6 IP 65

Area Classification

Zone 1 & 2

Apparatus Standard

IS - 2148

Material

Cast Aluminium LM 6

Weight

3 Kg (approx.)

Size

225(w) x 285(h) x 160(d) mm

IP Protection

IP 65 to IS 13947 / 93

Finish

Anti Corrosive Epoxy – Powder coated

Cable Entry

1 X 3/4″ ET

Gasket

Neoprene

Hardware

Stainless steel

Voltage

24V DC or 110V / 230V AC – 50 Hz

Power Rating

12 Watt

Sound Output

112db

Terminals

4 x 4 mm²

Earthing

External: 2 Nos – M6 Internal: 1 No. - M5


Conventional Fire Alarm Systems /

Zeta Magnetic Door Holders (ZT-DR24 & ZT-DR240)

ZT-BR

The Zeta magnetic door holders are designed to retain a fire door open against the force of its own closing device. In the event of a fire, the door holder magnet can be turned off by the fire alarm, allowing the door to shut. The manual release button is changeable from the base side to left or right. Cable entry is possible from rear side by means of enclosed exits from the base side, left or right. An optional bracket is also available for floor or wall mounting (ZT-BR).

Features Tested according to EN1155

Model

ZT-DR24

ZT-DR240

Part No.

50-001

50-002

Rated Voltage

24V DC

230V AC

Rated Current

65mA

6mA

Switch Through Aux

Yes

No

Needs Back EMF Diode

Yes

No

Holding Force

400 N

Size (Main Unit)

110 x 85 x 38mm

Dimensions (Keeper Plate)

55 x 55 x 50mm

Weight (Main Unit)

404g

Weight (Keeper Plate)

153g

39


Conventional Fire Alarm Systems /

Zeta Duct Unit (ZT-DU, ZT-DU/12 & ZT-DU/230)

The Zeta duct unit allows air in a ventilation duct to be monitored for smoke via a smoke detector mounted externally in a sealed chamber. The unit comes supplied with 2 sampling probes (one in & one out) which are mounted through the duct in the centre of the air flow.

There are 3 versions of the unit available which are as follows; ZT-DU – enclosure supplied with a Fyreye common base (FE-CB) allowing either a conventional or addressable Fyreye detector to be connected and wired as part a system. ZT-DU/12 – enclosure c/w Fyeye base and relay board with form C relay outputs for alarm and for fault which requires 12V power supply.

Test Point

ZT-DU/230 - enclosure c/w Fyeye base and relay board with form C relay outputs for alarm and for fault which requires 230V power supply. Duct Wall

Please note for reliable smoke detection the air speed in the duct must be at least 2.5m/s.

Features Direction of Airflow

Fire and Fault relays Option for latching or non-latching Manual reset (latching option)

40

Model

ZT-DU

ZT-DU/12

ZT-DU/230

Part No.

48-011A

48-011B

48-011C

Supply Voltage

N/A

12V

230V

Stand by current

N/A

46mA (From 12v supply)

Alarm current

N/A

86mA (From 12v supply)

Fault current

N/A

26mA (From 12v supply)

Indications

N/A

Power, fault & alarm

Outputs

N/A

1 x fault relay & 1 x alarm relay

Size

190 x 227 x 70mm

Weight

728g

989g


Conventional Fire Alarm Systems /

Premier Power Pack EN 54-4 Power Supply with LCD Screen (PP-2/12, PP-5/17) The Premier Power Pack Power supply uses an innovative design that allows the engineer to view system status through the on board LCD screen. The screen can display several power supply parameters, including output voltage, and output current. The power supply itself uses a 3 state charger which uses BOOST, FLOAT, and PULSE modes, depending on the state of the battery. The PSU will disconnect the batteries under mains fail condition, when the batteries are fully discharged to prevent damage to the batteries. The PSU will also monitor the battery for high internal resistance, and signal a fault if that condition is detected.

Screen Information System Normal Screen

Part No.

46-300

Input Voltage

170-264V AC 47-63 Hz

2 . 0 A

Output Voltage

28V DC Nominal

28V DC Nominal

Power Rating

75W

150W

Efficiency

79%

86%

Total Power Output

2.0 Amp

5.0 Amp

Power Supply Outputs

2 Fused Outputs

2 Fused Outputs

Maximum Current Per Output

0.625mA

2.0 Amps

R A T I N G

3 0 V

S Y S T E M

N O R M A L

D C

Screen 1 - Main Information M A I N S

:

O K

B A T T S

:

O K

V ( A ) = 2 9 . 5 C U R R E N T

46-305

E R

PP-5/17

S Y S T E M S

A L A R M

P R E M I

PP-2/12

P O W E R - P A C K

Z E T A

Model

V ( B ) = 2 9 . 5

0 . 1 2

A M P S

B A T T E R Y

I M P : 0 . 0 0 3 7

Battery Charging Current

750mA

920mA

C H A R G E R

V O L T : 2 5 . 4 5

V

Fault Relay Rating

SELV 1A

SELV 1A

B O O S T

IP Rating

IP30

IP30

S T A T E : G O O D

Size

375 x 335 x 128mm 375 x 403 x 128mm

Screen 2 - Battery Info

C H A R G E

T Y P E :

B A T T E R Y Screen 3 - Misc.

E A R T H : 2 . 4 4 7 V C H A R G E R B A D

C I R C U I

B A T T E R Y

L V L

G O O D

T :

O K

X . X R

Screen 4 - Software Information

S o f

t w a r e

P S U :

2 V 0 0

S o f

t w a r e

L C D :

2 V 0 0

41


Conventional Fire Alarm Systems /

Batteries (Z20201, Z20301, Z20651, Z21251 & Z21751)

As fire alarm systems are life safety systems, they must have a battery backup to ensure full functionality is maintained in the event of a mains failure. All parts of the system (including auxiliary power supplies) must have a battery backup. All the batteries stocked are 12V meaning that 2 batteries are required for a 24V systems. The standard capacities available are 2.2Ah, 3.2Ah, 7Ah, 12Ah and 17Ah. It is important to choose the correct battery size for the system load to give the required standby time (usually 24 or 48 hours).

Battery Calculation To calculate the required battery backup, we use the equation:Battery Size (Standby time in Amp Hours) = 1.25 x [(TALM x IALM) + (TSBY x ISBY)] Where: TALM = Maximum time in hours required for the alarm [½ hour is most common time] IALM = Total Alarm Current in amps for all alarm devices connected to the alarm circuits TSBY = Standby time in hours for the system after mains failure [normally 24, 48 or 72 hr] ISBY = Quiescent current in amps of control panel in fault condition [because of mains failure] PLUS all loop devices

42

Model

Z20201

Z20301

Z20651

Z21251

Z21751

Part No.

46-002

46-100

46-003

46-105

46-004

Type

Sealed lead acid

Voltage

12V DC

Capacity

2.2 Ah

3.2 Ah

7.2 Ah

12 Ah

17 Ah

Size

178 x 34 x 65mm

132 x 59 x 65mm

151 x 65 x 98mm

150 x 98 x 103mm

178 x 75 x 168mm

Weight

1.0kg

1.25kg

2.5kg

3.5kg

5.8kg



Available now from:

Tel: +44 (0) 1792 455 175 Fax: +44 (0) 1792 455 176 E-mail: info@zetaalarmsystems.com Web: www.zetaalarmsystems.com

Detection House 72-78 Morfa Road Swansea SA1 2EN United Kingdom


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.