BEST MANAGEMENT PRACTICES
SITE GENERAL NOTES
STORM WATER POLLUTION CONTROL REQUIREMENTS FOR CONSTRUCTION ACTIVITIES AND MINIMUM WATER QUALITY PROTECTION REQUIREMENTS FOR ALL DEVELOPMENT CONSTRUCTION PROJECT/CERTIFICATES: ● ERODED SEDIMENTS AND OTERH POLLUTANTS MUST BE RETAINED ON SITE AND MAY NOT BE TRANSPORTED FROM THE SITE VIA SHEETFLOW, SWALES, AREA DRAINS, NATURAL DRAINAGE COURSE OR WIND. ● STOCKPILES OF EARTH AND OTHER CONSTRUCTION RELATED MATERIALS MUST BE PROTECTED FROM BEING TRANSPORTED FROM SITE BY THE FORCES OF WIND OR WATER ● FUELS, OILS, SOLVENTS AND OTHER TOXIC MATERIALS MUST BE STORED IN ACCORDANCE WITH THEIR LISTING AND ARE NOT TO CONTAMINATE THE SOIL AND SURFACE WATER. ALL APPROVED STORAGE CONTAINERS ARE TO BE PROTECTED FROM THE WEATHER. SPILLS MUST BE CLEANED UP IMMEDIATELY AND DISPOSED OF IN A PROPER MANNER. SPILLS MAY NOT BE WASHED INTO THE DRAINAGE SYSTEM ● NON-STORM WATER RUNOFF FROM EQUIPMENT AND VEHICLE WASHING AND ANY OTHER ACTIVITY SHALL BE CONTAINED AT THE PROJECT SITE ● EXCESS OR WASTE CONCRETE MAY NOT BE WASHED INTO THE PUBLIC WAY OR ANY OTHER DRAINAGE SYSTEM. PROVISIONS SHALL BE MADE TO RETAIN CONCRETE WASTES ON SITE UNTIL THEY CAN BE DISPOSED OF AS A SOLID WASTE ● TRASH AND CONSTRUCTION RELATED SOLID WASTED MUST BE DEPOSITED INTO A COVERED RECEPTACLE TO PREVENT CONTAMINATION OF RAINWATER AND DISPERSAL BY WIND ● SEDIMENTS AND OTHER MATERIALS MAY NOT BE TRACKED FROM SITE BY VEHICLE TRAFFIC. THE CONSTRUCTION ENTRANCE ROADWAYS MUST BE SWEPT UP IMMEDIATELY AND MAY NOT BE WASHED DOWN BY RAIN OR OTHER MEANS. ● ANY SLOPES WITH DISTURBED SOILS OR DENUDED OF VEGETATION MUST BE STABILIZED SO AS TO INHIBIT EROSION BY WIND OR WATER.
A.) B.) C.) D.) E.) F.) G.) H.) I.)
CARLTON STREET
REFER TO SURVEY FOR EXISTING SITE CONDITIONS REFER TO CIVIL FOR GRADING AND DRAINAGE REFER TO CIVIL FOR CONNECTION OF ALL DOWNSPOUTS REFER TO CIVIL FOR UTILITY CONNECTIONS REFER TO SOILS REPORT OF SUB-GRADE PREPARATION LANDSCAPING AND IRRIGATION UNDER SEPARATE COVER 100% OF HARDSCAPE PAVING TO BE NATURAL GREY (UNCOLORED) CONCRETE WITH SMOOTH FINISH FOR REDUCTION OF HEAT ISLAND EFFECT FOR PROJECTS THAT INCLUDE LANDSCAPE WORK THE LANDSCAPE CERTIFICATION, FORM GRN 12, SHALL BE COMPLETED PRIOR TO FINAL INSPECTION SITE SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS WITH A MINIMUM FALL OF 6 INCHES WITHIN THE FIRST 10 FT.
(E) CURB
(E) DRIVEWAY APPROACH
(E) LANDSCAPE
(E) LANDSCAPE
(E) SIDEWALK
(E) LANDSCAPE
(E) LANDSCAPE
(E) DRIVEWAY
TYPE D UNIT 1:
Carlton Residence
SINGLE FAMILY RESIDENCE KITCHEN REMODEL AND ADDITION 3 BEDROOM 2 BATHROOM
APN: 1049313030000
AREA OF WORK 326.5 SQ FT
PROPERTY LINE
PROPERTY LINE
CITY OF ONTARIO, COUNTY OF SAN BERNARDINO, STATE OF CALIFORNIA
(E) GARAGE
Document Date: November 17, 2021
Document Phase: Construction Documents rev. date
remark
-
11/17/21
Submittal
1
---
---
(E) LANDSCAPE
Site Plan
PROPERTY LINE
N 1 Site Plan Proposed A1.1 1/8” = 1’-0” c ACDL
The use of these plans and specifications is restricted to the original site for which they were prepared. Re-use, reproduction or publication by any method in whole or in part is prohibited, unless authorized by Aaron Castaneda. Ownership of the design, plans and specifications is solely with Aaron Castaneda.
A1.1
FLOOR PLAN GENERAL NOTES
FLOOR PLAN KEYNOTES
ALL DIMENSIONS ARE FROM FACE OF STUD TO FACE OF STUD U.O.N. ALL DOORS SHALL BE FRAMED WIT 4” JAMBS TYP. U.O.N. ALL WINDOWS SHALL BE FRAMED WITH 3” JAMBS TYP. U.O.N. CEILING HEIGHTS ARE MEASURED FROM TOP OF SUB. FLOOR, TYP. U.O.N. INSTALL WATER RESISTANT GYPSUM BOARD (FULL HEIGHT) AROUND ALL SHOWER ENCLOSURES AND BEHIND ALL PLUMBING FIXTURES, EXCEPT BEHIND TILE, INSTALL DUROC, WONDERBOARD, OR EQUAL. PROVIDE BACKING FOR ALL TOWEL BARS AND TISSUE HOLDERS IN BATHROOMS, TYP. VERIFY ALL FINISH MATERIALS WITH ARCHITECT PRIOR TO INSTALLATION ALL BATHROOM FIXTURES SHALL BE EQUIPPED W/ A PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE. REFER TO REFLECTED CEILING PLAN FOR CEILING TO WALL INTERSECTIONS. “EGRESS” WINDOWS NOTED ON PLANS MUST HAVE A NET CLEAR OPENING OF 5.7 S.F., A SILL HEIGHT OF NOT MORE THAN 44” ABOVE GRADE LEVEL, A CLEAR HEIGHT OF NOT LESS THAN 24” AND CLEAR WIDTH OF NOT LESS THAN 20”
E. F. G. H. I.
THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.)
K. L.
TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES-WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. THE FLOW RATES FOR ALL NEW PLUMBING FIXTURES SHALL COMPLY WITH THE MAX. FLOW RATES SPECIFIED IN SECTION 4.303.1 WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWER HEAD, THE COMBINED FLOW RATE OF ALL THE SHOWER HEADS AND/OR OTHER OUTLETS CONTROLLED BY
A
M.
SINGLE VALVE SHALL NOT EXCEED 2.0 GALLONS PER MINUTE AT 80 PSI, OR THE SHOWER SHALL BE DESIGNED TO ONLY ALLOW ONE SHOWER HEAD, TO BE IN OPERATION AT A TIME ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE
WINDOW SCHEDULE EGRESS
REMARKS
NO.
OPERATION
MFR
WIDTH HEIGHT MATERIAL 36
36"
VINYL
MILGARD
NO
TEMPERED, DOUBLE PANE
HEIGHT
MATERIAL
D-101
SWING
36”
6’-8”
WOOD
SOLID WOOD
D-102
SWING
36”
6’-8”
WOOD
HALLOW CORE
D-103
SWING
36"
6’-8”
WOOD
HALLOW CORE
D-104
SWING
32"
6'8
WOOD
HALLOW CORE
NOT IN CONTRACT
DEMOLISH
5'-6 3/4"
9'-0"
1 A3.6
WIDTH
REMARKS
8'-8 5/8"
MFR
DOUBLE HUNG
3’ x 3’ MINIMUM LANDING, NOT MORE THAN 1 INCH BELOW TOP OF THE THRESHOLD OF EXT. OUT-SWING DOORWAYS. 2. FULLY TILED SHOWER ENCLOSURE. TILE TO EXTEND FULL HEIGHT OF WALL (> 70” ABV. DRAIN). ALL GLAZING AT ENCLOSURE TO BE TEMPERED WITH PERMANENT LABEL. REFER TO INTERIOR ELEVATIONS FOR TILE SELECTION AND PATTERN. 3. WEATHER STRIP AND METAL THRESHOLD OVER PAN FLASHING AT EXTERIOR DOORS 4. 24” DEEP LOWER CABINETS 5. 25” DEEP COUNTER WITH BACKSPLASH AT REAR AND SIDES 6. 12” DEEP UPPER CABINETS 7. 30” DEEP UPPER CABINETS 8. TOILET, 1.28 GALLON FLUSH 9. WATER HEATER CLOSET CONSTRUCTION IN ACCORDANCE WITH NFPA 9.1.23 10. COMBINATION CARBON MONOXIDE AND SMOKE DETECTOR (CONNECT TO ELECTRICAL SYSTEM W/BATTERY BACKUP) 11. 12" SHELF AND ROD AT 6'-0" ABOVE FINISH FLOOR
SIZE
OPERATION
W-101
1.
DOOR SCHEDULE
SIZE NO.
N.
OR
COVERED WITH TAPE, PLASTIC, OR SHEET METAL UNTIL THE FINAL STARTUP OF THE HEATING, COOLING AND VENTILATING EQUIPMENT ARCH. PAINTS AND COATINGS, ADHESIVES, CAULKS AND SEALANTS SHALL COMPLY WITH THE VOLATILE ORGANIC COMPOUND (VOC) LIMITS LISTED IN TABLES 4.504.1 4.504.3
LIVING ROOM
N.I.C .
LIVING ROOM
D-101
BEDROOM 1
BEDROOM 1
4 5 6
3'-0"
7 KITCHEN
2 A3.5
RESTROOM
4 5 6
46'-5 1/2"
10
DINNING ROOM 18'-1 3/4"
46'-5 1/2"
DINNING ROOM
2 A3.5
ENCLOSED PATIO
RESTROOM
D-102
4'-3/8"
3
November 17, 2021 Construction Documents
MASTER BEDROOM
W-101
Document Date: Document Phase:
10 D-101
Carlton Residence
C. D.
J.
37'-8 7/8"
A. B.
KITCHEN
rev. date
remark
-
11/17/21
Submittal
1
---
---
CLOSET 11
D-103
13'-9"
4'-11"
BEDROOM 2
BEDROOM 2
17"
3'-6"
2'-5"
11" 11"
5'-2"
7'-11"
13'-8 1/2"
4'-3 7/8"
8
2
MASTER BATHROOM
11"11"
5'-0"
MIN. 3'-4"
6'-9"
13'-7 1/8" 1 A3.6
1 A2.1
c ACDL
Floor Plan - Proposed 1/4” = 1’-0”
The use of these plans and specifications is restricted to the original site for which they were prepared. Re-use, reproduction or publication by any method in whole or in part is prohibited, unless authorized by Aaron Castaneda. Ownership of the design, plans and specifications is solely with Aaron Castaneda.
LAUNDRY ROOM
N
D-104
13'-7"
9
37'-2 3/8"
1 3 3'-0"
23'-7 3/8"
Floor Plan
N
MIN. 3'-4"
1 A2.1
Floor Plan - Existing 1/4” = 1’-0”
A2.1
DP. W.P. F PC P/M
J
F.E. H B GAS C H
SUB-PANEL (RECESSED IN WALL U.O.N.) SUB-PANEL (RECESSED IN WALL U.O.N.) DAMP PROOF WEATHERPROOF BOX & COVER FLUORESCENT FIXTURE PULL CHAIN PHOTO CELL / MOTION SENSOR CEILING EXHAUST FAN (50 C.F.M. MIN.) FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE TO THE OUTSIDE OF THE BUILDING. FANS NOT FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, MUST BE CONTROLLED BY A HUMIDITY CONTROL. JUNCTION BOX FUSED DISCONNECTION SWITCH FUSED DISCONNECTION SWITCH HOSE BIBB GAS OUTLET SHOWER HEAD +72” W/TWIST PULL SHOWER VALVE W/ HOT & COLD WATER STUB DUPLEX OUTLET (+12” U.O.N.) DUPLEX OUTLET-HALF SWITCHED (+12”) DUPLEX OUTLET AT COUNTERS SEE UTILITY NOTES 220 VOLT OUTLET (+36”) 4-PLEX OUTLET (+12”) GROUND FAULT INTERRUPTER CIRCUIT (MOUNTED @ +44” @ KITCHEN & BATHROOM COUNTER, U.O.N.)
UTILITY PLAN NOTES C H
M
S
S SD S3 S3D SMO
COLD WATER STUB HOT WATER STUB MOTOR FLUORESCENT LIGHT FIXTURE (2 TUBE) COMBINATION CARBON MONOXIDE AND SMOKE DETECTOR (CONNECT TO ELECTRICAL SYSTEM W/ BATTERY BACKUP, AND CONNECTED TOGETHER FOR SIMULTANEOUS OPERATION) TELEPHONE OUTLET (+12” U.O.N.) 2 WAY SWITCH (+48” TYPICAL) 2 WAY SWITCH W/ DIMMER (+48” TYPICAL) 3 WAY SWITCH (+48” TYPICAL) 3 WAY SWITCH W/ DIMMER (+48” TYPICAL) MANUAL-ON MOTION SENSOR SWITCH (+48” TYPICAL) PUSH BUTTON (MOUNT @ +48”) W/ ANODIZED PLATE WALL MOUNTED LIGHT FIXTURE (84” U.O.N.) SURFACE MOUNTED LIGHT FIXTURE PENDANT LIGHT FIXTURE RECESSED LIGHT FIXTURE
1. THIS PLAN IS FOR GENERAL LAYOUT PURPOSES ONLY. REFER TO FLOOR PLAN FOR BUILDING LAYOUT AND DIMENSIONS. 2. ALL FIXTURES TO BE HIGH EFFICIENCY L.E.D. OR FLUORECENT UNLESS OTHERWISE NOTED 3. ALL NEW ELECTRICAL OUTLETS TO BE TAMPER RESISTANT 4. ALL NEW ELECTRICAL CIRCUITS TO BE EQUIPED WITH AFCI PROTECTION 5. ALL ELECTRICAL OUTLETS ABOVE 36” HIGH COUNTERS TO BE MOUNTED AT +44” UON 6. ALL ELECTRICAL OUTLETS ABOVE 32” HIGH COUNTERS TO BE MOUNTED AT +40” UON 7. ALL ELECTRICAL OUTLETS AT ISLANDS TO BE MOUNTED AT +30” 8. ALL ELECTRICAL AND MECH. OUTLETS BEHIND REFRIGERATORS, OVENS, WASHERS AND DRYERS TO BE MOUNTED AT +36” 9. ALL BEDSIDE SWITCHES TO BE MOUNTED AT +36” 10. IN EVERY HABITANTS ROOM AN ELECTRICAL OUTLET SHALL BE INSTALLED SO THAT NO POINT ALONG THE FLOOR LINE IN ANY WALL SPACE IS MORE THAN 6’ MEASURED HORIZONTALLY FROM ANY OUTLET IN THAT SPACE. INCLUDING ANY WALL SPACE TWO FEET OR MORE IN WIDTH, THE WALL SPACE OCCUPIED BY FIXED PANELS IN EXTERIOR WALLS, AND FIXED ROOM DIVIDERS. 11. IN KITCHEN AND DINING AREAS OF DWELLING UNITS A RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH COUNTER SPACE 12” OR WIDER SO THAT NO POINT ALONG THE WALL LINE IS MORE THAN 24”, MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET IN THAT SPACE. ISLAND AND PENINSULAR COUNTER 12” OR WIDER SHALL HAVE AT LEAST ONE RECEPTACLE FOR EACH 4’-0” OF COUNTER TOP. COUNTER TOP SPACES SEPARATED BY RANGE TOPS, REFRIGERATORS, OR
SINKS SHALL BE CONSIDERED AS SEPARATE COUNTER SPACES. RECEPTACLES RENDERED INACCESSIBLE BY APPLIANCES FASTENED IN PLACE OR APPLIANCES OCCUPYING DEDICATED SPACE SHALL NOT BE CONSIDERED AS THESE REQUIRED OUTLETS. 12. PROVIDE TWO SEPARATE 20-AMP CIRCUIT FOR SMALL KITCHEN APPLIANCES PER CEC220-4(B) 13. PROVIDE 200-AMP ELECTRICAL SERVICE METER PANEL. 14. FORCED AIR UNITS ARE TO INCORPORATE “SUMMER SWITCH” FOR PORCED AIR VENTILATION 15. PROVIDE APPROVED NON-REMOVABLE BACK FLOW PREVENTION DEVICES 16. WATER METER, WATER LINE PIPE AND GAS LINE PIPE SIZING CALCULATIONS ALONG WITH ONE LINE ISOMETRIC DRAWINGS MAY BE REQUIRED TO BE PROVIDED IF THE BUILDING INSPECTOR REQUESTS THESE ITEMS 17. PLUMBING DRAIN WASTE AND VENT AND/OR MECH. DUCTING ALONG WITH ELECTRICAL PANEL WIRING SIZING CALCULATIONS MAY BE REQUIRED TO BE PROVIDED IF THE FIELD INSPECTOR REQUESTS THESE ITEMS 18. ALL LIGHTING FIXTURES AND LIGHTING OUTLETS OVER THE SPA OR WITHIN 5’ OF THE INSIDE WALLS SHALL BE A MINIMUM OF 7’-6” ABOVE THE MAXIMUM WATER LEVEL AND SHALL BE PROTECTED BY A GROUND-FAULT CIRCUIT. C.E.C. 680-41-B-1 19. THE TERMINATION OF ANY ENVIRONMENTAL AIR DUCT (IE. DRYERS, UTILITY FAN ETC.) SHALL BE A MINIMUM OF 3 FEET FROM ANY OPENING (IE. DOORS, WINDOWS, SKYLIGHTS, ATTIC VENTS ETC.) INTO A BUILDING, PER CMC. SECT. 504.6 20. ONE 20-AMP DEDICATED CIRCUIT SHALL BE PROVIDED TO SERVE THE REQUIRED BATHROOM OUTLETS, AND SHALL NOT SUPPLY ANY OTHER RECEPTACLES, LIGHTS, FANS ETC., PER CEC. ARTICLE 210-52 21. ALL BRANCH CIRCUITS THAT SUPPLY 125-VOLT SINGLE-PHASE, 15-20 AMPERE RECEPTACLE OUTLETS INSTALLED IN BEDROOMS OF DWELLING UNITS SHALL BE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER(S) 22. ELECTRICAL OUTLETS ON OPPOSITE SIDE OF FIRE WALLS SHALL BE SEPARATED BY A HORIZONTAL DISTANCE OF 24” 23. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE PROVIDED WITH INDIVIDUAL CONTROL VALVES OF THE THERMOSTATIC MIXING OR PRESSURE BALANCE TYPE 24. WHERE A SHOWER IS SERVED BY MORE THAN ONE SHOWER HEAD, THE COMBINED FLOW RATE OF ALL SHOWER HEADS AND/OR OTHER SHOWER OUTLETS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 2.0 GALLONS PER MINUTE AT 80PSI. 25. STATE HEALTH AND SAFETY CODE SEC. 17921.9 BANS THE USE OF CHLORINATED POLYVINYL CHLORIDE (CPVC) & CROSSLINKED POLYETHELEYN (PEX) FOR INTERIOR WATER - SUPPLYING PIPING 26. ALL OUTLETS AND SWITCHES TO BE WHITE DECORA UNLESS OTHERWISE NOTED 27. THE FLOW RATE FOR ALL PLUMBING FIXTURES SHALL COMPLY WITH THE MAXIMUM FLOW RATES SPECIFIED IN SECTION 4.303.1 OF THE CALIFORNIA GREEN BUILDING CODE 28. ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENTS SHALL BE COVERED WITH TAPE, PLASTIC, OR SHEET METAL UNTIL THE FINAL STARTUP OF THE HEATING, COOLING AND VENTILATING EQUIPMENT. 29. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED WITH NATURAL VENTILATION OR WITH MECHANICAL VENTILATION CAPABLE OF 50 CFM EXHAUSTED DIRECTLY TO THE OUTSIDE (R303.3)
Carlton Residence
UTILITY SYMBOL LEGEND
N.I.C .
S
S3 C
KITCHEN CEILING @ 8’ - 0”
Document Date: GAS
November 17, 2021 C
H
Document Phase:
S
Construction Documents
S3 S H C
rev. date
remark
-
11/17/21
Submittal
1
---
---
GAS
S
H
17"
SS C
MASTER BATH
C
CEILING @ 8’ - 0”
H
S
GAS
C
WH
Reflected Ceiling Plan
N 1 A2.2
c ACDL
Reflected Ceiling Plan - Proposed 1/4” = 1’-0”
The use of these plans and specifications is restricted to the original site for which they were prepared. Re-use, reproduction or publication by any method in whole or in part is prohibited, unless authorized by Aaron Castaneda. Ownership of the design, plans and specifications is solely with Aaron Castaneda.
FOR REFERENCE ONLY
A2.2
ELEVATION KEY NEW AREAS
1 A3.2
2 A3.2
15’ - 10” TOP OF ROOF
15’ - 10” TOP OF ROOF
15’ - 10” TOP OF ROOF
9’ - 6” ROOF PLATE
9’ - 6” ROOF PLATE
9’ - 6” ROOF PLATE
1’ - 6” FIRST FLOOR
0’ - 0” GROUND
0’ - 0” GROUND
4 Proposed East Elevation A3.1 1/4” = 1'-0"
Document Date:
1 A3.2
November 17, 2021
EXISTING AWNING 15’ - 10” TOP OF ROOF
15’ - 10” TOP OF ROOF
The use of these plans and specifications is restricted to the original site for which they were prepared. Re-use, reproduction or publication by any method in whole or in part is prohibited, unless authorized by Aaron Castaneda. Ownership of the design, plans and specifications is solely with Aaron Castaneda.
11/17/21
Submittal
1
---
---
W-101
6:12 9’ - 6” ROOF PLATE
1'-0" 1'-0"
8" MATCH FACADE TO EXISTING MATERIAL AND COLOR
1’ - 6” FIRST FLOOR
1’ - 6” FIRST FLOOR
0’ - 0” GROUND
0’ - 0” GROUND
1'-6"
(E) SIDING
5 1/4" 5 1/4" 5 1/4"
1'-6"
3 Proposed West Elevation A3.1 1/4” = 1'-0"
remark
-
8'-0"
11'-3/8"
9'-5 1/2"
D-101
(E) WOOD FRAME WALLS W/ 7/8" STUCCO
(E) SIDING
MATCH FACADE TO EXISTING MATERIAL AND COLOR
rev. date
6'-4" 9’ - 6” ROOF PLATE
D-104
(E) SIDING
2'-7 1/4"
6'-4"
(E) WOOD FRAME WALLS W/ 7/8" STUCCO
8'-0"
9’ - 6” ROOF PLATE
8"
Construction Documents
5'-4"
10 7/8"
15’ - 10” TOP OF ROOF
9’ - 6” ROOF PLATE
c ACDL
Document Phase:
EXISTING AWNING
15’ - 10” TOP OF ROOF
0’ - 0” GROUND
0’ - 0” GROUND
2 North Elevation A3.1 1/4” = 1'-0"
2 A3.2
1’ - 6” FIRST FLOOR
1’ - 6” FIRST FLOOR
1'-6"
0’ - 0” GROUND
1’ - 6” FIRST FLOOR
8'-0"
(E) WOOD FRAME WALLS W/ 7/8" STUCCO
1'-6"
1’ - 6” FIRST FLOOR
13'-3 1/4"
8'-0"
11'-3/8"
(E) WOOD FRAME WALLS W/ 7/8" STUCCO
15'-10"
9’ - 6” ROOF PLATE
Carlton Residence
6'-4"
15’ - 10” TOP OF ROOF
SUBFLOOR ACCESS MATCH FACADE TO EXISTING MATERIAL AND COLOR
(N) WOOD FRAME WALLS W/ 7/8" STUCCO W/ 2LAYERS GRADE D PAPER UNDER LATH TO MATCH EXISTING STUCCO
1 Proposed South Elevation A3.1 1/4” = 1'-0"
1’ - 6” FIRST FLOOR
Elevations
0’ - 0” GROUND
A3.1
Carlton Residence Document Date: November 17, 2021
Document Phase: KITCHEN
KITCHEN
Construction Documents rev. date
remark
-
11/17/21
Submittal
1
---
---
Building Sections 2 Section A3.2 3/8” = 1'-0"
c ACDL
The use of these plans and specifications is restricted to the original site for which they were prepared. Re-use, reproduction or publication by any method in whole or in part is prohibited, unless authorized by Aaron Castaneda. Ownership of the design, plans and specifications is solely with Aaron Castaneda.
1 Section A3.2 3/8” = 1'-0"
A3.2