Sample duct blaster

Page 1

Tom Barnes, Certified RESNET HERS Rater (508) 631-6633 buildingscience.ack@gmail.com

Duct Leakage Test Form for MA Code Compliance Client Information Name: Address: City, State Zip: Phone: E-mail:

Sample Nantucket, MA 02554

System #1 Location Crawl - serving 1st floor Type of test O Total O To Outside Approx. Floor Area Served 1,152 CFM Leakage at - 25 pa 77 Approx % leakage for single system* 6.7%

Building Information Address: City, State Zip: Test Date Test Time Point of Construction

Sample Nantucket, MA 02554 1/31/14 10:00 AM O Rough O Final

System #2 Location Attic - serving second floor Type of test O Total / O To Outside Approx. Floor Area Served 1,512 CFM Leakage at -25 pa 70 Approx % leakage for single system* 4.6% Combined Results Total Conditioned floor area Leakage limit 6.0% Leakage limit Combined Leakage** 2009 IECC Compliance

2,664 Sq. Ft. 8.0% 12.0% 320 147 cfm@-25p Pass Fail X

* Approximations for single systems are for diagnostic use only. ** Total combined duct leakage is required for 2009 IEEC Compliance. I certify that this test was performed in compliance with applicable standards

Tester's Signature

Date

HERS Rater Name:

Tom Barnes, RESNET Certified HERS Energy Rater

HERS Rater Company:

Nantucket Building Science, LLC

HERS Rater Provider:

RTIN #: 4583495