R
CHEMICAL OXYGEN DEMAND (COD) ANALYSIS SYSTEM MODEL NO.- ACM- LDES-2309
R
CHEMICAL OXYGEN DEMAND ANALYSIS SYSTEM MODEL NO.- ACM- LDES-2309
The microprocessor based automatic, advance, electronic and latest designed COD Analyzers are used for detection of Chemical Oxygen Demand. The Laboratory COD analyzer acts as water analyzer for detection of Chemical Oxygen Demand in both polluted and normal water. Weiber water analyzer works as high quality analysis tool for determination of inorganic pollution, waste water, sewage and Plant Effluent Treatment. Chemical Oxygen Demand (COD) is the laboratory measurement of amount of oxygen used in chemical reactions that occur in water as a result of the addition of wastes to it. It measures the sum total of organic and inorganic pollution in waste water. COD is a measure of the relative oxygen-depletion effect of a waste contaminant in water. It is an essentially a laboratory test which acts as wastewater quality indicator and will have a significant adverse effect aquatic life in water.This instrument is widely used by teaching or science research academy, petrochemical industry, water quality monitoring department and environmental protection department etc. Weiber's Fast Response COD Analysis System is ideal equipment for measuring COD and with an additional feature of giving fast results. COD is a kind of laboratory test to determine presence and intensity of waste in water sample, waste having either known or unknown composition. It is used for measurement of known substrates in synthetic wastes.
Measurement of COD in 타 Wastewater 타 Ecology 타 Study of freshwater ponds and lakes 타 Analysts and modelers working with determination of
water quality. TECHNOCRACY PVT. LTD.
R
Technical Specifications
Our Fast Response COD analysis system works on the principle of oxidation of oxidisable material with a given amount of potassium chromate, the titration of excess chromate and the calculation of oxygen consumed.Put a sample of 2.00 ml in a vial, heat it for 15 minutes, select the program and finally read the results displayed after the COD analysis is complete.
Frequency of Measurement Ground Water
Every 3 months
Lakes
Every 2 months
River
Every 2 weeks
Product Features Ÿ Transparent Protective Lid Ÿ Auto Shutdown at End of Completion of the Procedure Ÿ Technical Specifications
Technical Specifications
Temperature for COD 165°C TP / TN 105°C Capacity
24 vials of size 16 x 100 mm
Warm up Time
20 minutes
Power Requirements
220±22V, 50Hz, 300W
Ambient Operating Temperature
0 to 50 ℃
Temperature Stability
±1?
Accuracy
±1?
Timer
1-1680 minutes(31 hours) with audible alarm And feature of being automatic
Range Adjustment
105-165 ±1?, Shortcuts for 105? and 150?
TECHNOCRACY PVT. LTD.
An ISO 9001 : 2208 | ISO 14001 : 2008 | ISO 13485 WHO: GMP Products | GLP Compliant Products
www.acmasindia.com | www.cleanroom-equipments.com | www.measuring-meters.com
TECHNOCRACY PVT. LTD. SALES OFFICE (INDIA) Office no. 506 & 507, 5th Floor, Plot no.- C-9, Pearls Best Height-II, Netaji Subhash Place, Pitam Pura, Delhi- 110034 Land Line No.: +91 - 11- 47619688, Fax: +91-11-47619788 E-mail.: info@acmasindia.com
SALES OFFICE (HONG KONG) Unit D 28 11/F Wing Tat Comm,Bidg 97, Bonham Strand East, Sheung Wan, Hong Kong (PRC) Tel.: 0086-13929598046 0086- 18922303099 E-mail.: hk@acmasindia.com
SHOWROOM J-284 Sector 1 Bawana Industrial Estate, Bawana, Delhi, INDIA-110039 Tel.: 0091-0-9312219738 (M) +91- 9717741167 E-mail.: info@acmasindia.com
SALES OFFICE (RUSSIA) Inmed Trade Street Ozerkovsky Embankment, Unit No 50, Straine- 1, Off- 502, Moscow, Russia E-mail.: info@acmasindia.com Tel.: 0049- 79592345 | Email: russia@acmasindia.com