FLAME ATOMIC ABSORPTION SPECTROPHOTOMETER MODEL NO.- ACM--FAAS-2687
R
FLAME ATOMIC ABSORPTION SPECTROPHOTOMETER
FEATURES 타 Reasonable design, adopting the same key parts as in high end instruments, ensures basic functions but less
automation to provide an economic model for users 타 Built-in microprocessor with necessary auto-control and data processing functions achieve high reliability of the
instrument 타 Eye-catching digital display, multi-function data processing ability and fast function-key direct input realize easy
and fast analysis
R
SPECIFICATIONS Main Specification
Wavelength Range
190-900nm
Wavelength Accuracy
Âą0.5nm
Resolution
Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%.
Baseline Stability
0.005A/30min
Background Correction
The D2 lamp background correction capability at 1A is better than 30 times
Light Source System
Optical System
Lamp Turret
2 Lamps are powerd simultaneously (one preheated)
Lamp Current Adjustment
0~20mA
Lamp Power Supply Mode
400Hz Square Wave Pulse;
Monochomator
Single beam, Czerny-Turner design grating monochromator
Grating
1800 l/mm
Focal length
277mm
Blazed Wavelength
250nm
R
Flame Atomizer
Spectral Bandwidth
0.1nm, 0.2nm, 0.4nm, 1.2nm, automatic change
Adjustment
Manual adjustment for wavelength and slit
Burner
10cm single slot all-titanium burner
Spray Chamber
Corrosion resistant all-plastic spray chamber
Position Adjustment
Manual adjusting mechanism for vertical, horizontal positions and the rotation angle of the burner/min
Detection and Data
Gas Line Protection
Fuel gas leakage alarm/min
Detector
R928 Photomultiplier with high sensitivity and wide spectral range.
Processing System Electronic and micro-
Automatic adjustment of light source power.
computer system Display Mode
Light energy and negative high-voltage auto-balance LEC display of energy and measurement values, concentration direct reading.
Read Mode
Transient, time average, peak height, peak area, integral time is selectable in the range of 0.1~19.9s.
Scale Expansion
0.1~99
Data Processing Mode
Automatic calculation of mean, standard deviation and relative standard deviation.
R
Measurement Mode
Reporting number is in the range of 1~99 Automatic cureve fitting with 3~7 standards; Sensitivity autocorrection
Result Printing
Measurement data, working curve, signal profile and analytical conditions can all be printed out
Characteristic Concentration and Detection Limit
Instrument Self-Check
Check current status of each function key
Air-Acetylene
Cu: Characteristic concentration=0.025mg/L, Detection
Hydride vapor generator
limit=0.006mg/L;
can be connected for
Function Expansion
hydride analysis
Dimensions and Weight
Main unit
102Ă—49Ă—54cm, unpacked 80kg
An ISO 9001 : 2208 | ISO 14001 : 2008 | ISO 13485 WHO: GMP Products | GLP Compliant Products
www.acmasindia.com | www.cleanroom-equipments.com | www.measuring-meters.com
TECHNOCRACY PVT. LTD. SALES OFFICE (INDIA) Office no. 506 & 507, 5th Floor, Plot no.- C-9, Pearls Best Height-II, Netaji Subhash Place, Pitam Pura, Delhi- 110034 Land Line No.: +91 - 11- 47619688, Fax: +91-11-47619788 E-mail.: info@acmasindia.com
SALES OFFICE (HONG KONG) Unit D 28 11/F Wing Tat Comm,Bidg 97, Bonham Strand East, Sheung Wan, Hong Kong (PRC) Tel.: 0086-13929598046 0086- 18922303099 E-mail.: hk@acmasindia.com
SHOWROOM J-284 Sector 1 Bawana Industrial Estate, Bawana, Delhi, INDIA-110039 Tel.: 0091-0-9312219738 (M) +91- 9717741167 E-mail.: info@acmasindia.com
SALES OFFICE (RUSSIA) Inmed Trade Street Ozerkovsky Embankment, Unit No 50, Straine- 1, Off- 502, Moscow, Russia E-mail.: info@acmasindia.com Tel.: 0049- 79592345 | Email: russia@acmasindia.com