OMICS Lab

Page 1

Tabletop Autoclaves Class B For Dental & Medical Clinics

SIMPLICITY&

QUALITY


Tabletop Autoclaves Class B

Controller

Raw material

Air removal technology

Components quality

Productivity and efďŹ ciency

Documentation & traceability

Convenience at a glance

Effective use of energy

Ease of draining & ďŹ lling

Safety made easy

Design

Security

Communication

Standards and directives


Tabletop Autoclaves Class B Controller Programmable Microprocessor controller allow for creation of different cycle parameters. Five pre-programmed sterilization, cycle controls: Medical. Unwrapped. wrapped. Plastic. Helix (flash cycle).

Air Removal Technology Designed with A Bowie-Dick test for monitoring of pre-vacuum steam sterilizers operating and Detects air leaks, inadequate steam

Ease of Draining & Filling Manual and automatic water filling.

Productivity and Efficiency Fully automatic micro-processor control system. Reliability and effectiveness for infection control assurance. Monitoring is essential for quality of sterilization and excellent dry result. High quality temperature sensor with resolution 0.038C. High quality pressure sensor ceramic membrane transmitter with resolution 0.0015 bar. High quality vacuum pump for pre-vacuum and post-vacuum.


Convenience at a Glance Comfortable computer software with large LCD display 72mm X 40 mm. Indicate selected cycle, temperature, and pressure and exposure time. When the cycle start, the temperature, pressure and the remaining cycle time is displayed. As will service information for Bacteriological ďŹ lter removal, Lid gasket removal.

DESIGN Pure and uid lines not only give to the OMICSLAB sterilizer its elegance but, combined with quality material, they makes cleaning and surface disinfection very easy. There is no recess or corner where dirty can be accumulated.

COMMUNICATION - SD Card record all data from the sterilizer. - One USB port. - One Blue-Tooth port allow to communicate with individual or host computer. - Serial RS232 port allow to connect either standard RS232 printer or bar-code printer. - The software is suitable for Mac, Windows 7, Windows Vista, Windows XP and Linux.


RAW MATERIAL AND COMPONENTS QUALITY Chamber and door are made of stainless steel AISI 304L for Better corrosion resistance. fully isolated chamber. Both water tanks are stainless steel AISI 304L. - All enclosure is galvanized steel with epoxy paint. Vacuum pump speciďŹ cally designed for OMICSLAB autoclave is the result of long term collaboration with German company KNF. Solenoid valve with viton gasket and 3mm stainless steel ďŹ t are manufactured in Germany by Burkert Gmbh. All sensors are manufactured in Germany by Jumo regulation. All tubing is made of PTFE which avoid contamination and electro migration. Electrical wiring is made of silver plated copper insulated with TFE. Stainless steel adjustable rack, 4 aluminium trays as standard. up to 6 tray, It can be adjust to receive any type of load.

Documentation & traceability The new operating concept and the large LCD display and software enable a documentation procedure easy to use. All information are recorded on SD card: Logging of all physical value every two seconds.

Machine type and serial number. Cycle number. Cycle result. Easy Operator name. recorded Load type. on SD card Sterility validity.

If printer (optional) is connected, the print out with:

Machine type and serial number. cycle type. cycle number Upon request of the operator. Operator name. load type. load number. sterility validity. The 2D bar code.

Effective use of energy The contribution of intelligent systems to time saving and environment protection. Water consumption of less than 300ml combined with an electric power of only 2000 W. OMICSLAB sterilizer the most economical and most ecological autoclave on the market.


Safety made easy Quality assurance via instrument tracing enable instrument traceability within a matter of 2 seconds. A door locking device prevents a cycle from starting unless the door is properly locked. Pressure safety valves prevent over pressurization in chamber and generator. A safety thermostat prevents over heating in the chamber and generator. Detailed and descriptive indicators and alarms greatly enhance convenience and safety.

Security APAVE operational qualification As a complement to efficiency and quality testing carried out in the factory. An authorized organization to do an operational qualification with reference load vouching that it complies with applicable standards. This unique approach from the manufacturer guarantees that all marketed OMICSLAB autoclaves have been designed, certified and validated by abiding by all

Technical Standards - EN 13060 + A2 2004 - EN 867-5:2001 - EN 61326 - CEI 60417 - EN 554

Standards and Directives Quality Standards - ISO 9001:2008 - Quality Management Systems. - ISO 13485:2003 - Medical Devices. Directives - 93/42/EC ammended by Directive 2007/47/EC - 2006/95/EC Electrical device directive. - 97/23/EC - Pressure Equipment Directive. - EN285:1996

Safety standard - EN 61010-2-040 & EN 61010-2-41 - EN 61010-1 - EN 1497:2007

QUALITY STANDARDS

CYCLES AND TEST PROGRAM Type

Air Leakage

Empty Dynamic Chamber

Full load, double wrapped

A type hollow load

Small porous Full porous load, load, double wrapped double wrapped

Drying:full load double wrapped

Drying:full porous load double wrapped

Medical

B

X

X

X

X

X

X

X

X

unwrapped

B

X

X

X

X

X

X

X

X

wrapped

B

X

X

X

X

X

X

X

X

Plastic

B

X

X

X

X

X

X

X

X

Helix/Bowie Dick

B

X

X

X

X

X

X

X

X

Leakage

N/A


TECHNICAL DATA B300

B510

B630

Chamber size

Diameter: 250 mm Depth: 400 mm

Chamber volume

23 Litter

Temperature

105°C - 135°C

Pressure

1,1 bar - 2,15 bar

protection

Electrical protection/Board protection

B690

RS 232 USB port

Communication

Blue-tooth SD Card record all data water supply/ water draining

Manual water filling / Automatic exhaust

Automatic / Automatic exhaust Cleanwater: 4 L. Waste water: 4 L.

Water tank capacity Vacuum pump

Simple head vac. pump

Tank heating

Closed circuit, 1,6KW

Double head vac. pump Double tank heating(2KW)

Double tank heating(2,4KW)

Maximum noise level

< 50dB

Outer size

Height: 450 mm. Width: 510 mm. Depth: 540 mm.

Weight

55 kg

Power supply/ Frequency

230 VAC ± 10%/ 50-60 Hz

Power(W) / Current(A)

1600W/8A

2000W/10A

Steam generator

2400W/ 11A

2000W/10A

Total cycle time in minutes Unwrapped Wrapped Medical prion

Plastic B/D Helix Fast

B300

B510

B630

B690

70' 75' 85' 80' 35'

60' 65' 75' 80' 30'

50' 55' 65' 65' 25'

60' 35' 30' 25' 15'

Cycles time include drying.Times are given for machine starting cold with a typical load of 3 Kg.(Except B/D Helix)

Made In Europe


Tabletop Autoclaves Class B B300 Tank heating (closed circuit, 1,6KW) Simple head vac pump Manual water filling 1-3 cycles per day

B510 Double tank heating (2KW) Double head vac pump Manual and automatic water filling 1-5 cycles per day

B630 Double tank heating (2.4KW) Double head vac pump Manual and automatic water filling More than 5 cycles per day

B690 Steam generator (2KW) Double head vac pump Manual and automatic water filling More than 5 cycles per day