Airfel Panel Radiator (ENG)

Page 1

Safe Heating

www.airfel.com.tr

Panel Radiator& Towel Warmer, Valve


Daikin in the World

Japonya % 36

SINCE ITS BEGINNINGS IN THE 1950’S, DAIKIN HAS GROWN INTO A GLOBAL PLAYER IN THE HEATING, AIR CONDITIONING AND INDUSTRIAL CLIMATE CONTROL MARKET. Parent company Daikin Industries ltd. Is actively Engaged in a wide spectrum of technologies and Disciplines: from mechanics and electronics to Chemicals and fluorocarbons. Its japan operations Include major manufacturing locations and a new R&D Centre focused on the creation of next-generation Climate control technologies.

DAIKIN LEADS THE WAY In 1973, parent company daikin industries ltd. formed daikin europe N.V. in Ostend to tailor and market Daikin products to the specific needs and requirements of Europe, the Middle East, Russia and Africa. In 2006, daikin complemented its strong position in Japan and Europe with the acquisition of Asian HVAC-R giant OYL Industries Bhd., home to such names as Mc Quay (applied systems) and J&E Hall (refrigeration) and AAF (Air filtration). in addition to expanding its product offerings, the acquisition gave Daikin a significant presence in the North American and Asian markets.


Daikin in Europe DAIKIN EUROPE N.V. 26.000 m² Factory Area 1973 Production Start Product Range Daikin Altherma, Skyair, VRV, Chillers

ROTEX ISITMA SYSTEMS GMBH Factory Area 14.790 m² 1973 Production Start Heating Equipment Product Range

MCQUAY CRAMLINGTON Factory Area 5,209 m² Production Start 1966 Industrial Cooling, Product Range Air Handling Unit

DAIKIN INDUSTRIES CZECH REPUBLIC Factory Area 29.684 m² 2004 Production Start Split Air Conditioners Product Range

MCQUAY MILAN Factory Area Production Start Product Range

MCQUAY CECCHINA Factory Area Production Start Product Range

6.750 m² 2008 Air Handling Unit

22.000 m² 1969 Chillers and Compressors

DAIKIN INDUSTRIES CZECH REPUBLIC Factory Area 13.690 m² 2006 Production Start Product Range Compressors

DAIKIN TURKEY Factory Area 50.000 m² Production Start 2005 Fan coil, Air Conditioning Plant, Product Range Air Conditioner, Combi Boiler, Radiator

In addition to housing the european production and administration headquarters, Daikin europe N.v. Is home to the EMEA sales and marketing headquarters. The production site of Daikin Europe N.V. has grown into the most advanced plant of its kind in Europe with over 150,000 m2 of production and administrative space dedicated to manufacturing state-of-the-art residential, commercial and industrial heating and cooling solutions. European production facilities in Pilsen and Brno (Czech Republic), as well as Cecchina and Milan (Italy) and Cramlington (UK) have added to capacity and optimised lead times to all markets. With the acquisition of German heating manufacturer Rotex Gmbh and Turkish manufacturer Airfel Daikin Europe N.V. sas strengthened its offerings and expanded its market presence in the heating market.


Daikin Turkey

DAIKIN TURKEY, HENDEK FACTORY

Having been active in Turkey through its distributors since 1978, Daikin has become the most powerful players of industry with the acquisition of Airfel in July 2011. Today among other brands, Daikin has the widest product range in Turkey in heating, cooling and ventilation fields. Daikin Turkey manufactures Daikin and Airfel branded air conditioners, combi boilers, panel radiators, fancoils, air handling units etc. with cutting edge technology to offer total air conditioning solution to meet different customer needs. In production facilities of Daikin located in Hendek, Sakarya; along with Airfel branded units, Daikin branded products started to be manufactured. Having its head office in Istanbul, Daikin Turkey keeps its service quality at highest level with its sales network including 6 regional directorates in Adana, Ankara, Antalya, Gaziantep, İzmir and Trabzon, 170 dealers and 500 sales points and 501 authorized services. Daikin carries on its business to fulfill customer needs offering total comfort solutions with its wide product range, high technology production facilities, experienced and expert team in Turkey as well as globally. With Daikin, Turkey will be positioned as R&D, manufacturing and logistic base of Europe, Middle East and Africa and will be the most important air conditioning market of EMEA region.


Daikin Turkey Combi Boiler Production Plant Hendek / Sakarya Boiler production plant, which has a capacity of 300 thousand boiler production in a year, has also great emphasis on R&D studies. Our boilers are designed by a special team and manufactured with use of high quality components of industry. Products are tested for 100% security, function, tightness and pressure resistance. CE certifications are given by accredited laboratories of Europe.

Panel Radiator Production Plant Hendek / Sakarya Airfel radiator factory, which reached yearly 1.600.000 meter square production are with latest investments, is among limited number of facilities all around the world in panel radiator production field with high machine technology and cataphoresis coating. Whole manufacturing is made in full automatic weld lines. They are tested for 100% tightness, pressure resistance and presented with Airfel quality, which can be prove with the fact that our panel radiators have 12 years warranty.

Split Air Conditioner Production Plant Hendek / Sakarya Our air conditioners that are manufactured in our yearly 400 thousand set capacity split air conditioner factory, are tested for 100% electricity safety, function and high pressure in enthalpy, calorimetric and sound measurement laboratories. In addition to its high quality manufacturing copper pipe connections in critical positions are made by welding robots without any human contact.

Air Conditioning Production Plant Hendek / Sakarya Air Handling Units Production Plant, where hygienic package type and comfort type air handling units are manufactured by putting great importance on R&D studies, is the most modern facility in Turkey. Both home and abroad, our applied ventilation systems are preferred in hotel, hospitals, pharmaceutical plants, shopping centers, convention centers and office projects.

Fan coil Production Plant Hendek / Sakarya Our fan coil plant started its design and certification operation in 2009, now reached yearly 50 thousand fan coil production capacity. Our products are preferred at Turkey and abroad in several hotel and business centers due to their low sound level and high efficiency.


Panel Radiator High Efficiency

GREEN TECHNOLOGY Airfel Panel Radiators are produced environmentally-friendly by using Green Technology Zirconium coating technology instead of Zinc Phosphate coating technology.

GREEN

• Elimination of heavy metals such as Nickel, Zinc and Manganese, • Reduction of waste mud amount up to 95%, • Reduction of Phosphate amount within waste water • Water and electric energy saving through process stage reduction Ral 9010 and Ral 9016

TECHNOLOGY

Degreasing

Flushing

Destilation Flushing

Zirconium

Destilation Flushing

CATAPHORESIS PAINT TECHNOLOGY Cataphoresis is the most suitable painting technology developed for corrosion. In cataphoresis, an electro-chemical coating process, all surfaces are coated equally and completely. • Highly resistant against corrosion, • Smooth and penetrating coating on complex surfaces • Smooth film formation without fluxing and sagging • Environmentally sensitive since it is water based

HIGH THERMAL EFFICIENCY Airfel Panel Radiators: 1 running meter of Type 22 PKKP 600 series radiator gives 2228 kcal/h heat. (This value is given according to 90/70°C installation water and 20°C room temperature.)

HIGH TESTING PRESSURE Airfel panel radiators are resistant to, and safe against, high pressure with operational pressure of 10 bars and testing pressure of 13 bars.


Panel Radiator Types WIDE PRODUCT RANGE BY TYPE AND SIZE Produced by full automation system, Airfel radiators offer 6 different height options (300, 400, 500, 600, 750, 900 mm) with a wide product range. With 6 different models (p, pk, pp, pkp, pkkp, dkek) in 22 different lengths ranging from 40 cm to 3 m (increases by 100 m until 2 m and by 200 mm after 2 m), they meet all kinds of requirements. Panel radiator types are shaped according to the number of panel and convector used in their production. Type

Panel

Convector

10 P

1

0

11 PK

1

1

20 PP

2

0

21 PKP

2

1

22 PKKP

2

2

33 DKEK (PKKPKP)

3

3

Airfel panel is produced in 2 different models as standard (4 holes) and Compact Valve (6 holes). 1. Standard Type: Side-connected in accordance with classical connection system. Hot water inlet and outlet is performed from lateral surface of the radiator. 2. Compact Valve Type: Compact valve panel radiator is the most suitable radiator type for floor-fed and classical installation connection systems with high thermal power, sensitive rigging adjustment, thermostatic control and aesthetic view. Moreover, the special connection system inside enables connection of installation pipes from below and single side. Connection direction can be from left or right according to installation conditions. Compact valve panel can be applied for all radiator models. Moreover, separate thermostatic control can be provided for each radiator with addition of a thermostatic regulator. It has an aesthetic view and covers less space.

THERMOSTATIC VALVE COMPACT FITTING

COMPACT VALVE

OUTLET

INLET

Compatible Compact Fitting Types Ø18,4X2,7

41 0,5 43,6 0,4

G1/2"

Ø15,6 +- 0,0 0,1

AA19

M30X1,5

Ø

AA13

G1/2" 0,1

Ø12,42X1,78

0,5 33 +- 0,2

14,4

41

0,5

44,2

0,4 75

0,5


Technical Data mm A B F

10 P 45 14 Min.100

11 PK 45 49 Min.100

20 PP 45 70 Min.100

10P

21 PKP 45 70 Min.100

22 PKKP 45 104 Min.100

11PK

33 PKKPKP 45 160 Min.100

20PP

45 45

49

45

70

49

Min. 100 mm

Min. 100 mm

Min. 100 mm

49

Min. 100 mm

45

Min. 100 mm

14

Min. 100 mm

TİP 20 PP TİP 11 PK

21PKP

22PKKP

33DKEK

45

45

104

TİP 22 PKKP

TİP 21 PKP-KV

45

160

160

Min. 100 mm

Min. 100 mm

45

TİP 22 PKKP-KV TİP 33 PKKPKP

TİP 33 PKKPKP-KV

F

D

H

TİP 21 PKP

104

70

Min. 100 mm

45

Min. 100 mm

70

Min. 100 mm

45

TİP 20 PP-KV

TİP 11 P-KV

TİP 10 P- KV

TİP 10 P

Min. 100 mm

45

E

L3

L2 L1 L

RADIATOR LENGTH L (mm) 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2200 2400 2600 2800 3000

TYPE 10-20-21-22-33 L1 (mm) 133 233 333 433 533 633 733 833 933 1.033 1.133 1.233 1.333 1.433 1.533 1.633 1.733 1.933 2.133 2.333 2.533 2.733

L2 (mm) --------------767 800 867 967 1.067 1.167 1.267 1.367

L3 (mm) --------------767 833 867 967 1.067 1.167 1.267 1.367

TYPE 11 E 133 133 133 133 133 133 133 133 133 133 133 133 133 133 133 133 133 133 133 133 133 133

F 107 107 107 107 107 107 107 107 107 107 107 107 107 107 107 107 107 107 107 107 107 107

L1 (mm) 167 267 367 467 567 667 767 867 967 1.067 1.167 1.267 1.367 1.467 1.567 1.667 1.767 1.967 2.167 2.367 2.567 2.767

L2 (mm) --------------783 817 883 983 1.083 1.183 1.283 1.383

L3 (mm) --------------783 850 883 983 1.083 1.183 1.283 1.383

E 117 117 117 117 117 117 117 117 117 117 117 117 117 117 117 117 117 117 117 117 117 117

F 107 107 107 107 107 107 107 107 107 107 107 107 107 107 107 107 107 107 107 107 107 107


Technical Data Basic size

Distance between axes

Width

Lenght

Weight

6,1 7,9 9,7 11,5 14,3 17 8,4 11,1 13,5 16,2 20,5 24,3 12,1 15,8 19,5 23,2 28,8 34,3 13,8 18,2 22,5 26,9 33,9 40,4 15,9 21,1 25,9 31,1 39,5 47,1 23,8 31,5 38,7 46,5 59,1 70,4

Pressure Loss Pressure loss in radiators is dependent on water flow and radiator capacity. If flow is known, pressure loss can be found by using the graphic below. If the water flow is unknown, pressure can be calculated through the below method. Water drop (P) functions by radiator type: ΔP=Pressure Loss (Pa); m=Water flow (kg/h) Type 10 P, Type 11 PK ΔP=0.0233.m1.892 Type 20 PP, Type 21 PKP, Type 22 PKKP Type 33 PKKPKP ΔP=0.0114.m1.909

Water Volume

* Figures in technical table is are subject to change without prior notice. Figures are for 1m radiators.

Type


1472

1577

1682

1787

1892

1997

2102

211

282

352

423

493

564

634

705

775

846

916

987

300

400

500

600

700

800

900

1000

1100

1200

1300

1400

1500 1057

1600 1128

1700 1198

1800 1269

1900 1339

2000 1410

2207

2312

2417

2523

2628

2733

2838

2943

3048

3153

2100 1480

2200 1551

2300 1621

2400 1692

2500 1762

2600 1833

2700 1903

2800 1974

2900 2044

3000 2115

1366

1261

1156

1051

946

841

736

631

526

420

315

10

11

3759

3633

3508

3383

3257

3132

3007

2882

2756

2631

2506

2380

2255

2130

2005

1879

1754

1629

1503

1378

1253

1128

1002

877

752

626

501

376

20

4860

4698

4536

4374

4212

4050

3888

3726

3564

3402

3240

3078

2916

2754

2592

2430

2268

2106

1944

1782

1620

1458

1296

1134

972

810

648

486

21

120

140

300

˚F

˚F

TYPE

HIGH

Existance Water Temperature

Entrance Water Temperature

6223

6016

5808

5601

5394

5186

4979

4771

4564

4356

4149

3941

3734

3527

3319

3112

2904

2697

2489

2282

2074

1867

1660

1452

1245

1037

830

622

22

881

33

8807

8514

8220

7926

7633

7339

7046

6752

6459

6165

5871

5578

5284

4991

4697

4404

4110

3816

3523

3229

2936

2642

2349

2055

1761

1468

1174

68

˚F

Room Temperature

1048

786

22

1210 1572

1008 1310

807

605

21

400

1090 1412 1834

935

779

623

467

20

1467 1713 2218 2883

1333 1558 2017 2620

1200 1402 1815 2358

1067 1246 1613 2096

933

800

667

533

400

11

9803

9440

9077

8714

8351

7988

7625

7262

6899

6535

6172

5809

5446

5083

4720

4357

3994

3631

3268

2905

2542

2178

1815

1452

1089

33

1252

939

22

1194 1565

956

717

21

500

1112 1433 1877

927

741

556

20

1452 1668 2150 2816

1291 1483 1911 2503

1130 1298 1672 2190

968

807

646

484

11

2991 4357 5005 6450 8449

2881 4196 4819 6211 8136

2770 4034 4634 5972 7823

2659 3873 4449 5733 7510

2548 3712 4263 5494 7197

2437 3550 4078 5255 6884

2327 3389 3893 5016 6571

2216 3228 3707 4778 6258

2105 3066 3522 4539 5945

1994 2905 3336 4300 5632

1883 2743 3151 4061 5319

1773 2582 2966 3822 5007

1662 2421 2780 3583 4694

1551 2259 2595 3344 4381

1440 2098 2410 3105 4068

1330 1937 2224 2867 3755

1219 1775 2039 2628 3442

1108 1614 1854 2389 3129

997

886

776

665

554

443

332

10

2725 4000 4673 6050 7861 10892 3324 4841 5561 7166 9387

2634 3867 4517 5848 7599 10529 3213 4680 5375 6927 9074

12902

12472

12042

11612

11182

10752

10322

9891

9461

9031

8601

8171

7741

7311

6881

6451

6021

5591

5161

4731

4301

3871

3441

3010

2580

2150

1720

1290

33

1098

824

21

600

1075 1373

860

645

20

1324 1505 1922

1135 1290 1648

946

757

568

11

9740

9379

9019

8658

8297

7936

7576

7215

6854

6493

6133

5772

5411

5050

4690

4329

3968

3607

3247

2886

2525

2164

1804

1443

1082

22

3919 5676 6449 8238 10822

3788 5487 6234 7963 10462

3657 5298 6019 7688 10101

3527 5108 5804 7414

3396 4919 5589 7139

3266 4730 5374 6865

3135 4541 5159 6590

3004 4352 4944 6315

2874 4162 4729 6041

2743 3973 4514 5766

2612 3784 4299 5492

2482 3595 4084 5217

2351 3406 3869 4943

2221 3216 3654 4668

2090 3027 3439 4393

1959 2838 3224 4119

1829 2649 3010 3844

1698 2460 2795 3570

1567 2270 2580 3295

1437 2081 2365 3020

1306 1892 2150 2746

1176 1703 1935 2471

1045 1514 1720 2197

914

784

653

522

392

10

14856

14361

13866

13370

12875

12380

11885

11390

10894

10399

9904

9409

8914

8418

7923

7428

6933

6438

5942

5447

4952

4457

3962

3466

2971

2476

1981

1486

33 980

21

750

1030 1306

772

20

1388 1545 1960

1157 1287 1633

925

694

11

9874

9445

9016

8586

8157

7728

7298

6869

6440

6010

5581

5152

4722

4293

3864

3434

3005

2576

2147

1717

1288

22

4812 6940 7724 9799 12879

4652 6709 7467 9472 12450

4491 6478 7209 9145 12021

4331 6246 6952 8819 11591

4171 6015 6694 8492 11162

4010 5784 6437 8165 10733

3850 5552 6179 7839 10303

3689 5321 5922 7512

3529 5090 5664 7186

3369 4858 5407 6859

3208 4627 5149 6532

3048 4396 4892 6206

2887 4164 4634 5879

2727 3933 4377 5553

2567 3701 4120 5226

2406 3470 3862 4899

2246 3239 3605 4573

2085 3007 3347 4246

1925 2776 3090 3919

1765 2545 2832 3593

1604 2313 2575 3266

1444 2082 2317 2940

1283 1851 2060 2613

1123 1619 1802 2286

962

802

642

481

10

17749

17157

16566

15974

15383

14791

14199

13608

13016

12424

11833

11241

10649

10058

9466

8875

8283

7691

7100

6508

5916

5325

4733

4141

3550

2958

2367

1775

33

901

20

1372 1502

1098 1202

823

11

9800

9423

9046

8669

8292

7915

7538

7161

6784

6407

6030

5654

5277

4900

4523

4146

3769

3392

3015

2638

2261

1885

1508

1131

21

900

5716 8232 9013 11307

5525 7958 8713 10930

5334 7684 8412 10553

5144 7409 8112 10176

4953 7135 7811

4763 6860 7511

4572 6586 7211

4382 6312 6910

4191 6037 6610

4001 5763 6309

3810 5488 6009

3620 5214 5708

3429 4939 5408

3239 4665 5107

3048 4391 4807

2858 4116 4507

2667 3842 4206

2477 3567 3906

2286 3293 3605

2096 3019 3305

1905 2744 3004

1715 2470 2704

1524 2195 2404

1334 1921 2103

1143 1646 1803

953

762

572

10

AIRFEL PANEL RADIATOR CAPACITY (Btu/hr)

2543 3733 4361 5646 7337 10166 3102 4519 5190 6689 8761

2452 3600 4205 5445 7075

2361 3467 4050 5243 6813

2271 3333 3894 5041 6551

2180 3200 3738 4840 6289

2089 3067 3582 4638 6027

1998 2933 3427 4436 5765

1907 2800 3271 4235 5503

1817 2667 3115 4033 5241

1726 2533 2959 3831 4979

1635 2400 2804 3630 4717

1544 2267 2648 3428 4455

1453 2133 2492 3226 4193

1362 2000 2336 3025 3931

1272 1867 2181 2823 3669

1181 1733 2025 2621 3407

1090 1600 1869 2420 3145

999

908

817

727

636

545

454

363

272

10

62

˚F

ΔT

22

14794

14301

13808

13315

12822

12328

11835

11342

10849

10356

9863

9370

8876

8383

7890

7397

6904

6411

5918

5424

4931

4438

3945

3452

2959

2466

1973

1479

33

20618

19931

19243

18556

17869

17182

16494

15807

15120

14433

13745

13058

12371

11683

10996

10309

9622

8934

8247

7560

6873

6185

5498

4811

4124

3436

2749

2062

Heat Output


Airfel Valve Thermostatic Valve Thermostatic Radiator Valve detects temperature changes with the sensitive thermostat located on its valve and enables passage of water through radiators until desired room temperature is reached. Thus, it keeps the room temperature stable value between 7-28 °C Advantages: • Provides serious amounts of saving in fuel consumption amount you use for heating. • Ensures comfort with stable room temperature. • Provides separate temperature control for each room. • Provides balanced heating of all floors in multi-storey buildings.

Thermostatic Edge Radiator Valve

Thermostatic Straight Radiator Valve

Radiator Valve

Edge Radiator Valve

Straight Radiator Valve

Nickel Coating

Highest Tempature Maximum 120 0C

Sand Finish

PN 10

Use Type Straight,Edge

RoHS Place of Use Heating Systems Radiator Connections

579

Use Pressure

EN 216

TS EN ISO 9001:2008

Connector Threads


Towel Warmer • Aesthetic Models • Ease of use • Long life • High thermal efficiency

Technical Data Sizes

Width (A) mm

Height (H) mm

Weight

Connection Water Number Distance (L) Volume of Pipes mm Lt

Electrostatic Paint

Watt

Chrome Coating

Electrostatic Paint

Chrome Coating

Btu

Watt

Btu

Net Weight kg

Gross Weight Kg

Net Weight kg

Gross Weight Kg

400

700

355

13

2,57

267

912

201

686

4,14

4,49

4,14

4,49

500

700

455

13

2,98

316

1.079

237

809

4,80

5,15

4,80

5,15

600

700

555

13

3,39

365

1.246

274

936

5,35

5,75

5,35

5,75

400

800

355

14

2,86

294

1.004

221

755

4,60

4,95

4,60

4,95

500

800

455

14

3,30

348

1.188

261

891

5,30

5,70

5,30

5,70

600

800

555

14

3,74

400

1.366

300

1.024

5,90

6,30

5,90

6,30

400

1000

355

16

3,43

350

1.195

262

895

5,52

5,92

5,52

5,92

500

1000

455

16

3,93

410

1.400

308

1.052

6,30

6,75

6,30

6,75

600

1000

555

16

4,43

471

1.608

3053

10.424

7,00

7,45

7,00

7,45

400

1100

355

18

3,81

390

1.332

293

1.000

6,15

6,60

6,15

6,60

500

1100

455

18

4,38

457

1.560

342

1.168

6,98

7,43

6,98

7,43

600

1100

555

18

4,94

525

1.793

394

1.345

7,80

8,25

7,80

8,25

400

1200

355

20

4,20

429

1.465

322

1.099

6,80

7,25

6,80

7,25

500

1200

455

20

4,82

505

1.724

379

1.294

7,70

8,15

7,70

8,15

600

1200

555

20

5,45

580

1.980

435

1.485

8,60

9,10

8,60

9,10

400

1600

355

26

5,53

563

1.922

423

1.444

8,90

9,40

8,90

9,40

500

1600

455

26

6,35

661

2.257

496

1.694

10,10

10,60

10,10

10,60

600

1600

555

26

7,17

759

2.592

569

1.943

11,40

12,00

11,40

12,00

500

1800

455

31

7,30

768

2.622

575

1.963

11,75

12,45

11,75

12,45

600

1800

555

31

8,22

884

3.018

662

2.260

13,20

13,80

13,20

13,80

Head Off i ce Hürriyet Mah. Yakacık D-100 Kuzey Yan Yol No:49/1-2 Kartal ISTANBUL Tel: (+90216) 453 27 00 Fax: (+90216) 671 06 00 Factory Sakarya 2. Organize Sanayi Bölgesi Hendek SAKARYA Tel: (+90264) 616 27 00 Fax: (+90264) 654 58 46

www.airfel.com.tr • 444 999 0


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.