1 PAGE 1
Small pumps and pumping systems Application and accessory information
1-3
Oil-sealed pumps and accessories E2M0.7 two stage rotary pump E2M1.5 two stage rotary pump RV3 rotary vane pump RV5 rotary vane pump RV8 rotary vane pump RV12 rotary vane pump E-LAB 2 rotary pump Speedivac 2 one stage E1M18 one stage, E2M18 two stage E2M28 two stage rotary pump Electrical data Accessories
1-6 1-7 1-8 1-10 1-12 1-14 1-16 1-18 1-19 1-21 1-23 1-23
Scroll pumps XDS5 and XDS10 scroll pumps XDS5-C and XDS10-C scroll pumps XDS35i dry vacuum pump ESDP12 scroll pump
1-28 1-28 1-30 1-31
Diaphragm pumps and accessories D-LAB diaphragm pump & D-LAB accessories XDD1 diaphragm pump
Shop online at www.bocedwards.com
1-32 1-35
SMALL PUMPS AND PUMPING SYSTEMS
1 PAGE 2
To meet the diverse needs of applications ranging from analytical instrumentation, wet chemistry, R & D to light industrial, BOC Edwards offers a comprehensive range of different pumping technologies. Refer to the application and accessory guide to select pumps and accessories for your application: see page 1-3.
Oil free diaphragm pumps • 2 mbar / 1.5 Torr • 0.6 to 2.0 m3h-1 / 0.35 to 1.2 ft3min-1 The D-LAB diaphragm pumps are made of corrosion resistant materials, to withstand attack from chemicals. They are ideal for applications such as gel drying and other wet chemistry processes. The XDD1 diaphragm pumps provide oil free backing for compound turbomolecular pumps.
Easy to service
Oil sealed rotary vane pumps
All BOC Edwards pumps are designed for easy servicing. Key components are easily accessible and, with RV and XDS pumps, no special tools are required. Service kits of guaranteed parts are available for routine service by the user. Worldwide support from the BOC Edwards service organization is also available, see page 16-3.
Quality manufacture BOC Edwards pumps are manufactured on state of the art machine tools for high consistency of components. For example, RV rotors are manufactured in a robotic cell to remove errors and inconsistencies from the manufacturing process.
• 10-3 mbar / 10-3 Torr • 0.9 to 32.3 m3h-1 / 0.5 to 19.5 ft3min-1 This wide range of rugged pumps offers an excellent ultimate with good pumping speed. RV pumps have superior vapor handling capabilities, while operating quietly.
Oil free scroll pumps Scroll pumps are an excellent alternative to rotary vane pumps where oil free pumping is desirable. The innovative new XDS pumps in particular use a patented bearing shield to isolate the vacuum environment from all forms of lubricant not only making them totally dry, but also protecting the bearing from any process gases. Vapor handling is enabled by an adjustable gas ballast; this allows the range of pumps to satisfy many applications that were previously off limits to scroll pumps. • 2 x 10-2 mbar / 1.5 x 10-2 Torr • 5 to 35 m3h-1 / 2.9 to 20.6 ft3min-1
APPLICATIONS BOC Edwards high performance rotary pumps are used in many industrial and laboratory applications, including the following: • Epoxy degassing, powder materials processing • Solvent concentration • Sterilization, distillation and centrifuges • Gel dryers and glove boxes • Atomic emission spectrometers, nuclear physics, fusion technology and space research • Electron microscopes, mass spectrometry, residual gas analyzers and surface analysis • Vacuum ovens • TV tube evacuation • Automotive system filling • Freeze drying • Vacuum metallurgy
Shop online at www.bocedwards.com
SMALL PUMPS: APPLICATION AND ACCESSORY INFORMATION Use the information in the list below to select the best pump and accessories for your application. The information is given as a guide only; the optimum set-up may depend on your specific method of operation. Note that you need to buy the accessories separately, unless otherwise stated.
High energy physics Recommended pump: Rotary pumps (see page 1-5) or XDS (see page 1-28). Suggested accessories for rotary pumps: FL20K, Mist filter. Suggested accessories for XDS: Silencer.
Helium or rare gas recirculation
1 PAGE 3
Recommended pumps: XDS
Gel dryers Suggested accessories for D-Lab: Separator.
Alternative: EM18 or E2M28 Helium sealed variant. Contact BOC Edwards for more information.
Optional accessories for D-Lab: Condenser, gas ballast valve.
Backing turbomolecular pumps
Rotary evaporation and vacuum ovens
Recommended pump: Rotary pumps (see page 1-5) or XDS (see page 1-28).
Recommended pump: D-Lab (see page 1-32) or XDS (see page 1-28). Suggested accessories for D-Lab: Separator. Optional accessories for D-Lab: Condenser, gas ballast valve.
Suggested accessories for rotary pumps: FL20K, Mist filter. Suggested accessories for XDS: Silencer.
Backing diffusion pumps
Centrifugal concentration Recommended pump: XDS (see page 1-28).
Recommended pump: Rotary pumps (see page 1-5) or XDS (see page 1-28).
Vacuum filtration
Suggested accessories for rotary pumps: FL20K, Mist filter.
Recommended pump: D-Lab (see page 1-32) or XDS (see page 1-28).
Suggested accessories for XDS: Silencer.
Suggested accessories for D-Lab: Separator. Optional accessories for D-Lab: Condenser, gas ballast valve.
Distillation/extraction apparatus
Refrigeration, air conditioning systems Recommended pump: Rotary pumps (see page 1-5) or XDS (see page 1-28).
Recommended pump: D-Lab (see page 1-32) or XDS (see page 1-28).
Suggested accessories for rotary pumps: FL20K, Mist filter.
Suggested accessories for D-Lab: Separator.
Suggested accessories for XDS: Silencer.
Optional accessories for D-LAB: Condenser, gas ballast valve.
Vacuum furnace
Freeze dryers
Recommended pump: Rotary pumps (see page 1-5) or XDS (see page 1-28).
Recommended pump: Rotary pumps (see page 1-5).
Suggested accessories for rotary pumps: ITF20K, Mist filter.
Suggested accessories: Mist filters, oil return.
Suggested accessories for XDS: Silencer.
MS inlet systems (like electro-spray) Recommended pump: Rotary pumps (see page 1-5) or XDS (see page 1-28). Suggested accessories for rotary pumps: Mist filter, oil return. Suggested accessories for XDS: Silencer.
Azide forming applications Recommended pump: Rotary pumps (see page 1-5) or XDS (see page 1-28). Suggested accessories for rotary pumps: Mist filter. Suggested accessories for XDS: Silencer.
Load locks, fume hoods and glove boxes Recommended pump: Rotary pumps (see page 1-5) or XDS (see page 1-28).
Flameproof motors Available for RV pump only. Contact BOC Edwards for more information.
Suggested accessories for rotary pumps: Mist filter, oil return.
ATEX requirements:
Suggested accessories for XDS: Silencer.
Contact BOC Edwards for more information.
Ultra high speed centrifuges
Notes
Recommended pump: Rotary pumps (see page 1-5) or XDS (see page 1-28).
• FL20K is an inlet trap, to prevent oil back-streaming. • ITF20K is an inlet trap, to capture dust particles. • The gas ballast facility allows atmospheric air into the pump, minimizing the formation of condensates (which contaminate the oil in rotary pumps). • An oil return kit is available for RV and EM18 and E2M28 pumps to allow oil to be returned from the mist filter to the pump. A gas ballast oil return is also available to allow oil to return and have gas ballast flow.
Suggested accessories: Mist filter Suggested accessories for rotary pumps: Mist filters, oil return.
Leak detection, electron microscopes, mass spectrometers and lasers Recommended pump: Rotary pumps (see page 1-5) or XDS (see page 1-28). Suggested accessories for rotary pumps: FL20K, Mist filter. Suggested accessories for XDS: Silencer.
Surface science and particle size analyzers Recommended pump: Rotary pumps (see page 1-5) or XDS (see page 1-28). Suggested accessories for rotary pumps: FL20K, Mist filter. Suggested accessories for XDS: Silencer. Shop online at www.bocedwards.com
SMALL PUMPS AND PUMPING SYSTEMS
Recommended pump: D-Lab (see page 1-32) or XDS (see page 1-28).
SMALL PUMPS AND ACCESSORIES: FREQUENTLY ASKED QUESTIONS
1 PAGE 4
Question: How can I reduce the noise level of my pump?
Oil Mist
Answer: If the noise is only obvious during pumping down then fitting the exhaust with a silencer (XDS pumps), or fitting an exhaust line will reduce the level.
Question: What accessory do I use to trap oil mist (which all oil sealed pumps emit during pump down or with gas ballast)?
An alternative is to fit an acoustic enclosure. Contact BOC Edwards for more information.
Answer: To meet regulations and preserve pump oil, fit a recommended BOC Edwards oil mist filter (EMF) to the pump outlet, and connect the exhaust to an exhaust line. Question: If I operate an RV pump continuously or with high inlet pressure, what accessories do I need? Answer: Fit a BOC Edwards mist filter (EMF) and a gas ballast oil return (GBOR) kit. Then the pump can be operated with the mode switch open and gas ballast oil return. The oil condensed in the filter will be continuously returned to the pump oil box.
Vapor Processing Question: Which pump and accessories should I use if my process generates vapors which could condense in the pump? Answer: You can choose either an XDS pump, or rotary pump. Gas ballast should be used with both pumps; to sweep the vapor through the pump. This prevents condensation and oil contamination. Operate the pump with gas ballast for at least an hour before and after use. Choose the size of pump taking into account the vapor pumping rate. If you selected a rotary pump, then you should fit a gas ballast oil return kit and mist filter. Change the oil frequently and keep an oil change reminder tag on the pump. D-Lab would also be a suitable alternative depending on required pumping speed.
Dust and particle processes Question: Which pump and accessory should I use if my process generates dust or grit, which could clog or damage the pump? Answer: Use a rotary pump fitted with an inlet dust filter. We do not recommend the use of scroll pumps or XDD1 pumps for these applications.
Special chemical cleaning processes Question: Which pump and accessory should I use if my process generates oxygen or ozone? Answer: Use a rotary pump adapted to run with FomblinÂŽ oil or XDS. Contact BOC Edwards for more information. Question: Are there any special considerations if my pump will be used in the vicinity of organic gases, like propane? Answer: Use a rotary pump fitted with a flameproof motor. Contact BOC Edwards for more information.
Contamination Question: Which pump and accessories should I use if I must ensure that my process and process chamber (operated below 0.1 mb) are not contaminated with oil from the pump? Answer: Use an XDD1 pump or an XDS scroll pump. Alternatively, you can use a rotary pump with a FL20K foreline trap fitted to the system inlet. The trap contains activated alumina which traps the oil molecules. To maintain the alumina charge, bake the charge basket or replace as required.
FomblinÂŽ is a registered trademark of Solvay Solexis
Shop online at www.bocedwards.com
DATA SUMMARY
1 PAGE 5
Speed m3h-1 / ft3min-1 50 Hz 60 Hz Number of stages Ultimate vacuum* mbar / Torr without gas ballast with gas ballast Maximum water vapor pumping rate kg h-1
Pump
Catalog page Speed m3h-1 / ft3min-1 50 Hz 60 Hz Number of stages Ultimate vacuum* mbar / Torr without gas ballast with gas ballast Maximum water vapor pumping rate kg h-1
Pump
Catalog page Speed m3h-1 / ft3min-1 50 Hz 60 Hz Number of stages Ultimate vacuum* mbar / Torr
1
Speedivac 2
E2M0.7
E2M1.5
RV3
RV5
1-18
1-6
1-7
1-8
1-10
2.3 / 1.3 2.7 / 1.6 1
0.75 / 0.4 0.95 / 0.5 2
1.6 / 0.9 2.0 / 1.2 2
3.3 / 2 3.9 / 2.3 2
5.1 / 3 6.2 / 3.6 2
1.3 x 10-1 / 9.9 x 10-2 6 / 4.6 0.045
3 x 10-3 / 2.3 x 10-3 2.0 x 10-1 / 1.5 x 10-1 0.008
2.5 x 10-3 / 1.9 x 10-3 2.5 x 10-2 / 1.9 x 10-2 0.016
2 x 10-3 / 1.5 x 10-3 3 x 10-2 / 2.3 x 10-2
2 x 10-3 / 1.5 x 10-3 3 x 10-2 / 2.3 x 10-2 0.22
RV8
RV12
E1M18
E2M18
E2M28
1-12
1-14
1-19
1-19
1-21
8.5 / 5 10.0 / 5.9
12.0 / 7.1 14.2 / 8.4
2
2
17.0 / 10 20.4 / 12 1
17.0 / 10 20.4 / 12 2
27.5 / 16.2 33.0 / 19.5 2
2 x 10-3 / 1.5 x 10-3 3 x 10-2 / 2.3 x 10-2 0.22
2 x 10-3 / 1.5 x 10-3 3 x 10-2 / 2.3 x 10-2 0.29
3 x 10-2 / 2.2 x 10-2 6.5 x 10-1 / 4.8 x 10-1 0.65
1 x 10-3 / 7.5 x 10-4 1.5 x 10-2 / 1.1 x 10-2 0.3
1 x 10-3 / 7.5 x 10-4 1.5 x 10-2 / 1.1 x 10-2 0.7
D-LAB
XDS35i
XDS5/5C
XDS10/10C
ESDP12
XDD1
1-32
1-30
1-28
1-28
1-31
1-35
0.6, 1.2, 2.0 m3h-1 / 10, 20, 34 l min-1
35 / 21
4.8 / 2.8
9.3 / 5.5
12.5 / 7.3
1.2
-
1/2
35 / 21 1
6.0 / 3.5 1
11.1 / 6.5 1
15 / 8.8 2
1.4 3
100 / 75, 8 / 6
1 x 10-2 / 7.5 x 10-3
7 x 10-2 / 5 x 10-2
1.6 x 10-2 / 1.2 x 10-2
2 / 1.5
One head 100 / 75
Scientific 7 x 10-2 5.3 x 10-1
Two head 8/6
Chemical 9 x 10-1 / 6.8 x 10-1
Total pressure
Shop online at www.bocedwards.com
SMALL PUMPS AND PUMPING SYSTEMS
Pump
Catalog page
E2M0.7 TWO STAGE ROTARY PUMP 0.9 m 3 h -1 , 0.53 ft 3 min -1 , 15 l min -1
10
1
-1
ft 3 min -1
10
0
PAGE 6
10
-2
E2M0.7, 60Hz 10
-3
10
-4
10
-3
10
-2
10
-1
10
0
10
1
10
2
10
3
Torr
320 (12.60)
142 (5.59)
1
2
Maximum permitted pressure at outlet Maximum inlet pressure for water vapor Maximum water vapor pumping rate Motor power Operating temperature range Weight, without oil Noise Oil capacity - maximum Oil capacity - minimum Recommended oil (supplied) 10
123 (4.84)
19 (0.75)
25 (0.98)
47 (1.85) NW10
30 (1.18)
3 x 10-3 mbar / 2.3 x 10-3 Torr 2.0 x 10-1 mbar / 1.5 x 10-1 Torr NW10 flange Nozzle 11 mm external Ø removable from £/8 in BSP tapped hole 0.5 bar gauge / 7 psig 15 mbar / 11 Torr 8 g h-1 0.09 kW 12 - 40 °C 10 kg / 22 lbs 43 dB(A) @ 50 Hz 0.28 liter 0.2 liter Ultragrade 15
1 Handle (can be removed)
2 110-120 V motor, A = 189
3 220-240 V motor, B = 160
4 Alternative inlet position
ORDERING INFORMATION PRODUCT DESCRIPTION
E2M0.7 pump, 1-ph 220-240 V, 50/60 Hz 100-120 V, 50/60 Hz
1
ORDERING NUMBER
A37131919 A37131902
Supplied with: Ultragrade 15 oil, NW ‘ O’ ring and centering ring. SPARES
ORDERING NUMBER
The clean and overhaul kit contains all of the springs, gaskets, seals and other components required for routine maintenance and whenever the pump is dismantled. Add a blade kit for a full service. Both kits contain instructions and part identification. Clean and overhaul kit A37101131 Blade kit A37101132 NW10 centering ring and ‘ O’ ring C10511396 NW10 ‘ O’ ring (pack of five) H02124032 EMF3 outlet mist filter £/8 inch BSP to NW10 adaptor
-1
171 (6.73)
65 (2.65)
99 (3.90)
ORDERING NUMBER
A46220000 A25908064
For electrical data, including recommended fuse ratings, see page 1-23. For other accessories, see page 1-23 to 1-27. For rotary pump oils, see page 13-43.
-2
E2M0.7, 50Hz 10
140 (5.51)
124 (4.88)
0.9 m3h-1 / 0.5 ft3min-1 1.1 m3h-1 / 0.6 ft3min-1 0.75 m3h-1 / 0.4 ft3min-1 0.95 m3h-1 / 0.5 ft3min-1
0
m 3 h -1 10
4
110 (4.33)
ACCESSORIES 10
154 (6.06)
B
42.5 42.5 (1.67) (1.67)
TECHNICAL DATA Displacement (swept volume) 50 Hz Displacement (swept volume) 60 Hz Speed (Pneurop 6602) 50 Hz Speed (Pneurop 6602) 60 Hz Ultimate vacuum (total pressure) without gas ballast with full gas ballast Inlet connection Outlet connection
0.7
A
140.5 (5.53)
The E2M0.7 features a very low sound level of only 43 dB(A), compact dimensions, low energy consumption and low operating temperature. It will appeal to scientific instrument manufacturers and laboratory users for backing small turbomolecular or diffusion pumps as well as general laboratory applications. Fitted in a cabinet, the pump will be virtually inaudible and the low operating temperature will minimize the heat load on the equipment. Vertical vacuum inlet with horizontal option.
11 (0.43)
226 (8.90)
3
-3
10
10
-3
10
-1
10
-2
0
10
10
-1
1
10
10
0
2
10
10
1
3
10
10
2
4
mbar
Pa
(Total Pressure)
1
50 Hz, without gas ballast
Shop online at www.bocedwards.com
10
1
10
0
ft 3 min -1
E2M1.5 TWO STAGE ROTARY PUMP 1.8 m 3 h -1 , 1.1 ft 3 min -1 , 30 l min -1
1
-1
10
-2
PAGE 7
E2M1.5, 60Hz 10
-4
10
1
-3
10
-2
10
60 Hz without gas ballast
-1
10
2
0
10
1
10
2
Torr
60 Hz with gas ballast
320 (12.60)
142 (5.59)
1
2
1
10
0
m 3 h -1
10
1
10
-1
10
-2
10
-2
10
-1
10
-1
10
0
10
1
25 (0.98) 0
10
1
10
2
10
3
mbar
10
2
10
3
10
4
10
5
Pa
2
NW10
1 Handle (can be removed)
2 110 - 120 V motor, A = 189
3 220 - 240 V motor, B = 160
4 Alternative inlet position
ORDERING INFORMATION PRODUCT DESCRIPTION
E2M1.5 pump, 1-ph, standard 220-240 V, 50/60 Hz 100-120 V, 50/60 Hz
ORDERING NUMBER
A37122919 A37122902
Supplied with: Ultragrade 15 oil, NW ‘ O’ ring and centering ring, 2 Allen keys, spares seals for oil drain and filler plugs. SPARES
ORDERING NUMBER
The clean and overhaul kit contains all of the springs, gaskets, seals and other components required for routine maintenance and whenever the pump is dismantled. Add a blade kit for a full service. Both kits contain instructions and part identification. Clean and overhaul kit A37101131 Blade kit A37101132 NW10 centering ring and ‘ O’ ring C10511396 NW10 ‘ O’ ring (pack of five) H02124032 EMF3 outlet mist filter £/8 inch BSP to NW25 adaptor
10
171 (6.73)
47 (1.85)
ACCESSORIES
50 Hz without gas ballast
123 (4.84) 99 (3.90)
ORDERING NUMBER
A46220000 A25908064
For electrical data, including recommended fuse ratings, see page 1-23. For other accessories, see page 1-23 to 1-27. For rotary pump oils, see page 13-43.
(Total Pressure)
1
65 (2.65)
30 (1.18)
3 x 10-3 mbar / 2.3 x 10-3 Torr 2.5 x 10-2 mbar / 1.9 x 10-2 Torr NW10 flange Nozzle 11 mm external diameter removable from hole tapped £/8 in BSP 0.5 bar gauge / 7 psig 15 mbar / 11 Torr 16 g h-1 0.16 kW 12 - 40 °C 10 kg / 22 lbs 54 dB (A) @ 50 Hz 0.28 liter 0.2 liter Ultragrade 15
E2M1.5, 50Hz -3
140 (5.51)
124 (4.88)
1.8 m3h-1 / 1 ft3min-1 2.2 m3h-1 / 1.3 ft3min-1 1.6 m3h-1 / 0.8 ft3min-1 2.0 m3h-1 / 1.2 ft3min-1
2
10
4
110 (4.33)
TECHNICAL DATA
Maximum permitted pressure at outlet Maximum inlet pressure for water vapor Maximum water vapor pumping rate Motor power 50/60 Hz (IP54) Operating temperature range Weight Noise Oil capacity - maximum minimum Recommended oil (supplied)
154 (6.06)
B
A
140.5 (5.53)
42.5 42.5 (1.67) (1.67)
The interstage version features an additional pumping port to provide a rough vacuum for auxiliary duties.
Displacement (swept volume) 50 Hz Displacement (swept volume) 60 Hz Speed (Pneurop 6602) 50 Hz Speed (Pneurop 6602) 60 Hz Ultimate vacuum (total pressure) without gas ballast with gas ballast Inlet connection Outlet connection
1.5
19 (0.75)
This miniature two stage pump features an alternative inlet connection position at the side of the pump so that overall installation height can be reduced to a minimum when required.
11 (0.43)
226 (8.90)
3
50 Hz with gas ballast
Shop online at www.bocedwards.com
SMALL PUMPS AND PUMPING SYSTEMS
10
1
2
RV3 ROTARY VANE PUMP 3.7 m 3 h -1 , 2.2 ft 3 min -1 , 61.7 l min -1
1
10
0
10
-1
10
-2
3
m h
-1
1
10
PAGE 8
1
2
3
RV3, 50Hz 10
-3
10
-2
10
-1
10
0
10
1
10
2
10
3
mbar
10
-1
10
0
10
1
10
2
10
3
10
4
10
5
Pa
(Total Pressure)
1 50 Hz high vacuum mode, gas ballast = 0 2 50 Hz high throughput mode, gas ballast = 0 and high vacuum mode, gas ballast = I 3 50 Hz high vacuum and high throughput modes, gas ballast = II
TECHNICAL DATA 10
1
10
0
3
3.3 m3h-1 / 2 ft3min-1 3.9 m3h-1 / 2.3 ft3min-1
-1
3.7 m3h-1 / 2.2 ft3min-1 4.5 m3h-1 / 2.6 ft3min-1
ft min
Displacement 50 Hz operation 60 Hz operation Speed (Pneurop 6602) 50 Hz operation 60 Hz operation
High flow, II
3 x 10-2 mbar / 2.3 x 10-2 Torr 6 x 10-2 mbar / 4.6 x 10-2 Torr 1.2 x 10-1mbar / 9.1 x 10-2 Torr
Inlet connection NW25 Outlet connection NW25 Maximum allowed outlet pressure 1 bar gauge / 14 psig Maximum allowed inlet and gas ballast pressure 0.5 bar gauge / 7 psig Maximum water vapor inlet pressure 80 mbar / 60 Torr Maximum water vapor pumping rate Gas ballast low flow 60 g h-1 Gas ballast high flow 220 g h-1 Motor power 50Hz 250 W 60Hz 300 W Electrical supply 1-phase 110-120 V or 220-240 V, 50 or 60 Hz 3-phase 200-230 V or 380-460 V, 50 or 60 Hz Operating temperature range 12 - 40 ยบC Weight, without oil 21.6 kg / 47.3 lbs Noise 48 dB(A) @ 50 Hz Oil capacity Maximum 0.7 liter Minimum 0.42 liter Recommended oil (supplied) Ultragrade 19
RV3, 60Hz 10
-1
10
-3
10
-2
10
-1
10
0
10
1
10
2
10
3
Torr
1 60 Hz high vacuum mode, gas ballast = 0 2 60 Hz high throughput mode, gas ballast = 0 and high vacuum mode, gas ballast = I 3 60 Hz high vacuum and high throughput modes, gas ballast = II
430 (16.93)
37 (1.46)
32 (1.26)
1
29 (1.14)
127 (5)
3
120 (4.72)
267 (10.51)
Low flow, I
2 x 10-3 mbar / 1.5 x 10-3 Torr 3 x 10-2 mbar / 2.3 x 10-2 Torr
4 (0.16)
Closed
221 (8.70)
GAS BALLAST
3
2
1
ULTIMATE VACUUM (TOTAL PRESSURE) HIGH VACUUM MODE HIGH THROUGHPUT MODE
78 (3.07)
4 x ร 9 (0.35)
10 (0.39)
230 (9.06)
158 (6.22) 429 (16.89) NW25
NW25
2
1
1-phase motor
Shop online at www.bocedwards.com
2
3-phase motor
3
Retractable handle
ORDERING INFORMATION PRODUCT DESCRIPTION
ORDERING NUMBER
1 A65201903 A65201906
PAGE 9
A65201904
SMALL PUMPS AND PUMPING SYSTEMS
RV3 pump 115/230 V, 50/60 Hz Factory set to 230 V for Europe Factory set to 115 V for USA 100/200 V, 50/60 Hz Factory set to 200 V for Japan 200-220/380-415 V, 50 Hz and 200-230/460 V, 60 Hz, 3-ph Factory set to 380/460 V
A65201905
Supplied with: 1 liter of Ultragrade 19 oil, inlet filter and ‘ O’ ring. SPARES
ORDERING NUMBER
The clean and overhaul kit contains all of the springs, gaskets, seals and other components required for routine maintenance and whenever the pump is dismantled. Add a blade kit for a full service. Clean and overhaul kit (Viton®) A65201131 Blade kit A65201130 Outer shaft seal kit A65201134 Inlet valve kit A65201036 Motor, 1-phase A65299000 Motor, 3-phase A65297000 Cartridge kit A65201032 ACCESSORIES
2 m electrical supply cable with IEC socket UK, three-pin plug North European plug North America/Japan plug No plug RV gas-ballast adaptor RV exhaust nozzle kit, £/4 inch BSP to 15 mm hose EMF10 outlet mist filter
ORDERING NUMBER
A50505000 A50506000 A50507000 A50508000 A50502000 A50509000 A46226000
For electrical data, including recommended fuse ratings, see page 1-23. For other accessories, see page 1-23 to 1-27. For rotary pump oils, see page 13-43. For PFPE oil filled pumps, flameproof motored pumps and air motor driven pumps contact BOC Edwards.
Viton® is a registered trademark of Dupont Dow Elastomers
Shop online at www.bocedwards.com
RV5 ROTARY VANE PUMP 5.8 m 3 h -1 , 3.4 ft 3 min -1 , 96.7 l min -1
1
10
0
m h
-1
1
10
1
3
PAGE 10
10
-1
10
-2
2
3
RV5, 50Hz 10
-3
10
-2
10
-1
10
0
10
1
10
2
10 mbar
3
10
-1
10
0
10
1
10
2
10
3
10
4
10 Pa
5
(Total Pressure)
1
50 Hz high vacuum mode, gas ballast = 0
2
50 Hz high throughput mode, gas ballast = 0 and high vacuum mode, gas ballast = I
3
50 Hz high vacuum and high throughput modes, gas ballast = I
TECHNICAL DATA
High flow, II
10
0
-1 3
1
2
3
ULTIMATE VACUUM (TOTAL PRESSURE) HIGH VACUUM MODE HIGH THROUGHPUT MODE
2 x 10-3 mbar / 1.5 x 10-3 Torr 3 x 10-2 mbar / 2.3 x 10-2 Torr
3 x 10-2 mbar / 2.3 x 10-2 Torr 6 x 10-2 mbar / 4.6 x 10-2 Torr 1 x 10-1 mbar / 9.1 x 10-2 Torr
Inlet connection NW25 Outlet connection NW25 Maximum allowed outlet pressure 1 bar gauge / 14 psig Maximum allowed inlet and gas ballast pressure 0.5 bar gauge / 7 psig Maximum water vapor inlet pressure 50 mbar / 38 Torr Maximum water vapor pumping rate Gas ballast low flow 60 g h-1 Gas ballast high flow 220 g h-1 Motor power 50Hz 250 W 60Hz 300 W Electrical supply 1-phase 110-120 V or 220-240 V, 50 or 60 Hz 3-phase 200-230 V or 380-460 V, 50 or 60 Hz Operating temperature range 12 - 40 ยบC Weight, without oil 21.5 kg / 43 lbs Noise 48 dB(A)@ 50 Hz Oil capacity Maximum 0.7 liter Minimum 0.42 liter Recommended oil (supplied) Ultragrade 19
RV5, 60Hz 10
-1
10
-3
10
-2
10
-1
10
0
10
1
10
2
10
3
Torr
1
60 Hz high vacuum mode, gas ballast = 0
2
60 Hz high throughput mode, gas ballast = 0 and high vacuum mode, gas ballast = I
3
60 Hz high vacuum and high throughput modes, gas ballast = I
430 (16.93)
37 (1.46)
32 (1.26)
1
29 (1.14)
127 (5)
3
120 (4.72)
267 (10.51)
Low flow, I
5.1 m3h-1 / 3 ft3min-1 6.2 m3h-1 / 3.6 ft3min-1
4 (0.16)
Closed
1
221 (8.70)
GAS BALLAST
10
5.8 m3h-1 / 3.4 ft3min-1 7.0 m3h-1 / 4.1 ft3min-1 ft min
Displacement 50 Hz operation 60 Hz operation Speed (Pneurop 6602) 50 Hz operation 60 Hz operation
78 (3.07)
4 x ร 9 (0.35)
10 (0.39)
230 (9.06)
158 (6.22) 429 (16.89) NW25
NW25
2
1
1-phase motor
Shop online at www.bocedwards.com
2
3-phase motor
3
Retractable handle
ORDERING INFORMATION PRODUCT DESCRIPTION
ORDERING NUMBER
1 A65301903 A65301906
PAGE 11
A65301904
SMALL PUMPS AND PUMPING SYSTEMS
RV5 pump 115/230 V, 50/60 Hz, Factory set to 230 V for Europe Factory set to 115 V for USA 100/200 V 50/60 Hz Factory set to 200 V for Japan 200-220/380-415 V, 50 Hz and 200-230/460 V, 60 Hz, 3-ph Factory set to 380/460 V
A65301905
Supplied with: 1 liter of Ultragrade 19 oil, inlet filter and ‘ O’ ring. SPARES
ORDERING NUMBER
The clean and overhaul kit contains all of the springs, gaskets, seals and other components required for routine maintenance and whenever the pump is dismantled. Add a blade kit for a full service. Clean and overhaul kit A65201131 Blade kit A65301130 Outer shaft seal kit A65201134 Inlet valve kit A65201036 Motor, 1-phase A65299000 Motor, 3-phase A65297000 Cartridge kit A65301032 ACCESSORIES
2 m electrical supply cable with IEC socket UK, three-pin plug North European plug North America/Japan plug No plug RV gas-ballast adaptor RV exhaust nozzle kit, £/4 inch BSP to 15 mm hose EMF10 outlet mist filter
ORDERING NUMBER
A50505000 A50506000 A50507000 A50508000 A50502000 A50509000 A46226000
For electrical data, including recommended fuse ratings, see page 1-23. For other accessories, see page 1-23 to 1-27. For rotary pump oils, see page 13-43. For PFPE oil filled pumps, flameproof motored pumps and air motor driven pumps contact BOC Edwards.
Shop online at www.bocedwards.com
RV8 ROTARY VANE PUMP 9.7 m 3 h -1 , 5.7 ft 3 min -1 , 162.7 l min -1
1
10
0
m h
-1
1
10
1
3
PAGE 12
10
-1
10
-1
2
3
RV8, 50Hz 10
-3
10
-1
10
-2
10
-1
10
0
10
1
10
0
10
2
10
1
10
2
10 mbar
3
10
3
10
4
10 Pa
5
(Total Pressure)
TECHNICAL DATA
High flow, II
-1
3 x 10-2 mbar / 2.3 x 10-2 Torr 4 x 10-2 mbar / 3 x 10-2 Torr 6 x 10-2 mbar / 4.6 x 10-2 Torr
Inlet connection NW25 Outlet connection NW25 Maximum allowed outlet pressure 1 bar gauge / 14 psig Maximum allowed inlet and gas ballast pressure 0.5 bar gauge / 7 psig Maximum water vapor inlet pressure 38 mbar / 60 Torr Maximum water vapor pumping rate Gas ballast low flow 60 g h-1 Gas ballast high flow 220 g h-1 Motor power 50Hz 450 W 60Hz 550 W Electrical supply 1-phase 110-120 V or 220-240 V, 50 or 60 Hz 3-phase 200-230 V or 380-460 V, 50 or 60 Hz Operating temperature range 12 - 40 ยบC Weight, without oil 26 kg / 57 lbs Noise 48 dB(A) @ 50 Hz Oil capacity Maximum 0.75 liter Minimum 0.45 liter Recommended oil (supplied) Ultragrade 19
1
3
3
2
10
-1
10
-1
RV8, 60Hz 10
-3
10
-2
10
-1
10
0
10
1
10
2
10
3
Torr
1
60 Hz high vacuum mode, gas ballast = 0
2
60 Hz high throughput mode, gas ballast = 0 and high vacuum mode, gas ballast = I
3
60 Hz high vacuum and high throughput modes, gas ballast = II
470 (18.50)
37 (1.46)
32 (1.26)
161 (6.34)
1
35 (1.38)
120 (4.72)
261 (10.28)
Low flow, I
8.5 m3h-1 / 5 ft3min-1 10 m3h-1 / 5.9 ft3min-1
ULTIMATE VACUUM (TOTAL PRESSURE) HIGH VACUUM MODE HIGH THROUGHPUT MODE
2 x 10-3 mbar / 1.5 x 10-3 Torr 3 x 10-2 mbar / 2.3 x 10-2 Torr
0
50 Hz high vacuum and high throughput modes, gas ballast = II
4 (0.16)
Closed
10
50 Hz high throughput mode, gas ballast = 0 and high vacuum mode, gas ballast = I
3
221 (8.70)
GAS BALLAST
9.7 m3h-1 / 5.7 ft3min-1 11.7 m3h-1 / 6.9 ft3min-1
1
50 Hz high vacuum mode, gas ballast = 0
2
ft min
Displacement 50 Hz operation 60 Hz operation Speed (Pneurop 6602) 50 Hz operation 60 Hz operation
10
1
78 (3.07)
4 x ร 9 (0.35)
230 (9.06)
10 (0.39)
158 (6.22) 469 (18.46) NW25
2
1
1-phase motor
Shop online at www.bocedwards.com
2
3-phase motor
NW25
ORDERING INFORMATION PRODUCT DESCRIPTION
ORDERING NUMBER
1 A65401903 A65401906
PAGE 13
A65401904
SMALL PUMPS AND PUMPING SYSTEMS
RV8 pump 115/230 V, 50/60 Hz, Factory set to 230 V for Europe Factory set to 115 V for USA 100/200 V 50/60 Hz Factory set to 200 V for Japan 200-220/380-415 V, 50 Hz and 200-230/460 V, 60 Hz, 3-ph Factory set to 380/460 V
A65401905
Supplied with: 1 liter of Ultragrade 19 oil, inlet filter and ‘ O’ ring. SPARES
ORDERING NUMBER
The clean and overhaul kit contains all of the springs, gaskets, seals and other components required for routine maintenance and whenever the pump is dismantled. Add a blade kit for a full service. Clean and overhaul kit A65201131 Blade kit A65401130 Outer shaft seal kit A65201134 Inlet valve kit A65201036 Motor, 1-phase A65499000 Motor, 3-phase A65497000 Cartridge Kit A65401032 ACCESSORIES
2 m electrical supply cable with IEC socket UK, three-pin plug North European plug North America/Japan plug No plug RV gas-ballast adaptor RV exhaust nozzle kit, £/4 inch BSP to 15 mm hose EMF10 outlet mist filter
ORDERING NUMBER
A50505000 A50506000 A50507000 A50508000 A50502000 A50509000 A46226000
For electrical data, including recommended fuse ratings, see page 1-23. For other accessories, see page 1-23 to 1-27. For rotary pump oils, see page 13-43. For PFPE oil filled pumps, flameproof motored pumps and air motor driven pumps contact BOC Edwards.
Shop online at www.bocedwards.com
RV12 ROTARY VANE PUMP 14.2 m 3 h -1 , 8.4 ft 3 min -1 , 237 l min -1
2
10
1
10
0
10
-1
10
-2
m h
-1
1
10
3
PAGE 14
1
2
3
RV12, 50Hz 10
-3
10
-2
10
-1
10
0
10
1
10
2
10 mbar
3
10
-1
10
0
10
1
10
2
10
3
10
4
10 Pa
5
(Total Pressure)
1
50 Hz high vacuum mode, gas ballast = 0
2
50 Hz high throughput mode, gas ballast = 0 and high vacuum mode, gas ballast = I
3
50 Hz high vacuum and high throughput modes, gas ballast = II
TECHNICAL DATA
Low flow, I High flow, II
ULTIMATE VACUUM (TOTAL PRESSURE) HIGH VACUUM MODE HIGH THROUGHPUT MODE
2 x 10-3 mbar /
3 x 10-2 mbar /
1.5 x 10-3 Torr
2.3 x 10-2 Torr
-2
10-2
3 x 10 mbar /
4x
2.3 x 10-2 Torr
3 x 10-2 Torr
mbar /
1
10
0
10
-1
10
-2
3
ft min
-1
10
1
2
RV12, 60Hz 10
-3
10
Inlet connection NW25 Outlet connection NW25 Maximum allowed outlet pressure 1 bar gauge / 14 psig Maximum allowed inlet and gas ballast pressure 0.5 bar gauge / 7 psig Maximum water vapor inlet pressure 32 mbar / 24 Torr Maximum water vapor pumping rate Gas ballast low flow 60 g h-1 Gas ballast high flow 290 g h-1 Motor power 50Hz 450 W 60Hz 550 W Electrical supply 1-phase 110-120 V or 220-240 V, 50 or 60 Hz 3-phase 200-230 V or 380-460 V, 50 or 60 Hz Operating temperature range 12 - 40 °C Weight, without oil 26.3 kg / 58 lbs Noise 48 dB(A) @ 50 Hz Oil capacity Maximum 1.0 liter Minimum 0.65 liter Recommended oil (supplied) Ultragrade 19
-2
10
-1
10
0
10
1
10
2
10
3
Torr
1
60 Hz high vacuum mode, gas ballast = 0
2
60 Hz high throughput mode, gas ballast = 0 and high vacuum mode, gas ballast = I
3
60 Hz high vacuum and high throughput modes, gas ballast = II
6 x 10-2 mbar / 4.6 x 10-2 Torr
3
490 (19.29)
37 (1.46)
32 (1.26)
181 (7.13)
1
35 (1.38)
120 (4.72)
261 (10.28)
Closed
12.0 m3h-1 / 7.1 ft3min-1 14.2 m3h-1 / 8.4 ft3min-1
2
4 (0.16)
GAS BALLAST
14.2 m3h-1 / 8.4 ft3min-1 17.0 m3h-1 / 10 ft3min-1
10
221 (8.70)
Displacement 50 Hz operation 60 Hz operation Speed (Pneurop 6602) 50 Hz operation 60 Hz operation
78 (3.07)
4 X Ø9 (0.35)
230 (9.06)
10 (0.39)
158 (6.22) 489 (19.25) NW25
2
1
1-phase motor
Shop online at www.bocedwards.com
2
3-phase motor
NW25
ORDERING INFORMATION PRODUCT DESCRIPTION
ORDERING NUMBER
1 A65501903 A65501906
PAGE 15
A65501904
SMALL PUMPS AND PUMPING SYSTEMS
RV12 pump 115/230 V, 50/60 Hz, Factory set to 230 V for Europe Factory set to 115 V for USA 100/200 V 50/60 Hz Factory set to 200 V for Japan 200-220/380-415 V, 50 Hz and 200-230/460 V, 60 Hz, 3-ph Factory set to 380/460 V
A65501905
Supplied with: 1 liter of Ultragrade 19 oil, inlet filter and ‘ O’ ring. SPARES
ORDERING NUMBER
The clean and overhaul kit contains all of the springs, gaskets, seals and other components required for routine maintenance and whenever the pump is dismantled. Add a blade kit for a full service. Clean and overhaul kit A65201131 Blade kit A65501130 Outer shaft seal kit A65201134 Inlet valve kit A65201036 Motor, 1-phase A65499000 Motor, 3-phase A65497000 Cartridge kit A65501032 ACCESSORIES
2 m electrical supply cable with IEC socket UK, three-pin plug North European plug North America/Japan plug No plug RV gas-ballast adaptor RV exhaust nozzle kit, £/4 inch BSP to 15 mm hose EMF20 outlet mist filter
ORDERING NUMBER
A50505000 A50506000 A50507000 A50508000 A50502000 A50509000 A46229000
For electrical data, including recommended fuse ratings, see page 1-23. For other accessories, see page 1-23 to 1-27. For rotary pump oils, see page 13-43. For PFPE oil filled pumps, flameproof motored pumps and air motor driven pumps contact BOC Edwards.
Shop online at www.bocedwards.com
E-LAB 2 ROTARY PUMP 3.7 m 3 h -1 , 2.2 ft 3 min -1 , 61.7 l min -1
4.5 4.0
1
3.5 1 3.0
PAGE 16
m 3 h -1
2 2.5 2.0 1.5 1.0 0.5
E-LAB2
0 -2 10
10
10
0
10
-1
10
1
10
0
2
10
10
1
10
3
10
2
10
4
10
3
5
mbar
Pa
(Total Pressure)
1
60 Hz
2
50Hz
3.0
2.5
ft 3 min -1
2.0 1 1.5 2 1.0
The E-LAB 2 pump includes all the components needed for laboratory applications such as wet chemistry and sample preparation. Based on BOC Edwards proven experience with vacuum pumps and developments in accessories, the E-LAB 2 pump allows continuous running, even in the presence of water and solvents.
0.5
E-LAB2 0 10
-2
1
10
60 Hz
TECHNICAL DATA
Operating temperature range Weight, pump only, without oil Noise Oil capacity Maximum Minimum Recommended oil 1
10
2
0
10
1
10
2
10
3
Torr
50Hz
127 (5.0)
69 (2.72)
Ø12.7 (0.5)
3.7 m3h-1 / 2.3 ft3min-1 4.5 m3h-1 / 2.6 ft3min-1 3.3 m3h-1 / 1.9 ft3min-1 3.9 m3h-1 / 2.3 ft3min-1 1 x 10-1 mbar / 7.6 x 10-2 Torr !/2 inch id hose adaptor !/2 inch id hose adaptor 1 bar gauge / 14 psig 0.5 bar gauge / 7 psig 40 mbar / 30 Torr 95 g h-1 99.999%
450 (17.72)
Displacement 50 Hz operation 60 Hz operation Speed (Pneurop 6602) 50 Hz operation 60 Hz operation Ultimate vacuum (total pressure) Inlet connection Outlet connection Maximum allowed outlet pressure Maximum allowed inlet pressure Maximum water vapor inlet pressure Maximum water vapor pumping rate Mist filter oil trap efficiency Motor power 50 Hz 60 Hz Electrical supply1
-1
OIL
OIL
120 (4.73) 158 (6.22)
250 W 300 W 110-120 V or 220-240 V, 50 or 60 Hz 12 - 40 °C 21.6 kg / 47.3 lbs 50 dB(A) @ 50 Hz 0.7 liter 0.42 liter Ultragrade 19
Other voltage versions are available on request.
Shop online at www.bocedwards.com
4 x Ø9 (0.35)
230 (9.06) 430 (16.93)
156 (6.14)
ORDERING INFORMATION PRODUCT DESCRIPTION
E-LAB2 pump, 1-ph Universal motor, set to 220-240 V Universal motor, set to 110-200 V
ORDERING NUMBER
A65207903 A65207906
1 PAGE 17
Supplied with: outlet mist filter, oil return kit, inlet trap, oil change tag, nozzles, elbow, all fittings, 1 liter of oil, instruction manual. Assembly necessary. ORDERING NUMBER
The clean and overhaul kit contains all of the springs, gaskets, seals and other components required for routine pump maintenance and whenever the pump is dismantled. Add a blade kit for a full service. Clean and overhaul kit A65201131 Blade kit A65201130 Outer shaft seal kit A65201134 Inlet valve kit A65201036 Oil mist filter element A22304198 Oil mist filter odor element (pack of 5) A22304079 ACCESSORIES
2 m electrical supply cable with IEC socket UK three-pin plug North European plug North America/Japan plug No plug
ORDERING NUMBER
A50505000 A50506000 A50507000 A50508000
For electrical data, including recommended fuse ratings, see page 1-23. For other accessories, see page 1-23 to 1-27. For rotary pump oils, see page 13-43.
Shop online at www.bocedwards.com
SMALL PUMPS AND PUMPING SYSTEMS
SPARES
SPEEDIVAC 2 ONE STAGE 2.7 m 3 h -1 , 1.59 ft 3 min -1 , 45 l min -1
10
2
SPEEDIVAC 2, 60Hz
1
10
1
1
ft 3 min -1
PAGE 18
10
0
2
10
-1
10
-4
10
-3
10
-2
10
-1
1 60 Hz without gas ballast
114 (4.49)
10 (0.39)
10 (0.39)
PRODUCT DESCRIPTION
Speedivac 2 pump, 1-ph 220-240 V, 50 Hz 105-115 V, 50/60 Hz
0
m 3 h -1
2
ACCESSORIES
EMF3 outlet mist filter
-1
10
10
-2
0
10
10
-1
1
10
10
0
10
2
10
1
3
10
10
2
4
10
10
3
5
mbar
Pa
(Total Pressure)
1
12 (0.47)
Ø8.5 (0.34) /11 (0.43) /15 (0.59) 20 (0.79)
ORDERING NUMBER
A13451912 A13451988
50 Hz without gas ballast
ORDERING NUMBER
A13401811 A13401820 ORDERING NUMBER
A46220000
For electrical data, including recommended fuse ratings, see page 1-23. For other accessories, see page 1-23 to 1-27. For rotary pump oils, see page 13-43.
-2
-1
20 (0.79)
1
9 (0.35) 4 x Ø8.5 (0.34)
Supplied with: Ultragrade 19 oil, non-return valve with nozzle 15 mm external diameter and nozzle 11 mm external diameter for inlet, nozzle 12 mm diameter for outlet.
Spares kit, comprising blades, springs, seals, gaskets and washers Seals kit
10
140 (5.51)
Capacitor (105-115 V version only)
SPARES
-3
Torr
ORDERING INFORMATION
1
10
3
Drawing of pump shown with outlet nozzle and valved inlet nozzle fitted.
SPEEDIVAC 2, 50Hz 10
10
Ø12 (0.47)
0.5 liter 0.2 liter Ultragrade 19
1
10
53 53 (2.09) (2.09)
1
2©12 nozzle supplied
10
2
147 (5.79)
1©8.5/11 mm nozzle and ©15 valved nozzle supplied
10
10
152 (5.98)
126 (4.96)
1.3 10-1 mbar / 9.9 x 10-2 Torr 6 mbar / 4.6 Torr !/4 inch BSP tapped hole1 £/8 inch BSP tapped hole2 0.5 bar gauge / 7 psig 25 mbar / 19 Torr 0.045 kg h-1 12.5 kg 0.18 kW
with 2 l min-1 gas ballast flow Inlet connection Outlet connection Maximum permitted pressure at outlet Maximum water vapor inlet pressure Maximum water vapor pumping rate Weight Motor power 50 Hz or 60 Hz Oil capacity Maximum Minimum Recommended oil (supplied)
1
61 (2.40)
3.5 (0.14)
2.7 m3h-1 / 1.6 ft3min-1 3.2 m3h-1 / 1.9 ft3min-1 2.3 m3h-1 / 1.3 ft3min-1 2.7 m3h-1 / 1.6 ft3min-1
Displacement (swept volume) 50 Hz Displacement (swept volume) 60 Hz Speed (Pneurop 6602) 50 Hz Speed (Pneurop 6602) 60 Hz Ultimate vacuum (total pressure) without gas ballast
10
90 (3.54)
TECHNICAL DATA
0
376 (14.80)
37 (1.46)
90 (3.54)
122 (4.80)
37 (1.46)
10
2 60 Hz with gas ballast
2 50 Hz with gas ballast
Shop online at www.bocedwards.com
E1M18 ONE STAGE, E2M18 TWO STAGE 20.5 m 3 h -1 , 12.1 ft 3 min -1 , 342 l min -1
10
2
1
1
1
ft 3 min -1
10
1 10
PAGE 19
2
0
E2M18
E1M18
2
-1
10
-4
10
1
-3
10
-2
10
-1
10
0
10
Without gas ballast
2
1
10
2
10
3
Torr
With gas ballast
A B 3 (0.12)
Maximum permitted pressure at outlet Maximum inlet pressure for water vapor (mbar / Torr) Maximum water vapor pumping rate Weight Noise Motor power 50 Hz Motor power 60 Hz Oil capacity Maximum Minimum Recommended oil (supplied)
10
10
1.4 liter 1.05 liter 0.9 liter 0.75 liter Ultragrade 19
1 2
3
4
0
E1M18
50Hz
-1
10
10
-3
10
-1
10
-2
0
10
10
-1
1
10
10
0
2
10
10
1
3
10
10
(Total Pressure)
1
E2M18 50 Hz without gas ballast
2
E2M18 50 Hz with gas ballast
3
E1M18 50 Hz without gas ballast
4
E1M18 50 Hz with gas ballast
227 (8.94)
G
E1M18
E2M18
2
4
mbar
Pa
39 (1.54)
43 (1.69)
25 (0.98)
E NW25
F
ORDERING NUMBER
A
B
C
D
E
F
G
A343-10-940 A343-15-904 A343-17-984 A363-10-940 A363-15-904 A363-17-984
515 608 -
471 471 501 519 519 549
247 247 247 295 295 295
81 81 81 129 129 129
159 159 159 207 207 207
180 162 162 180 162 162
238 238 251 238 238 251
ORDERING INFORMATION PRODUCT DESCRIPTION
1
E2M18 10
50 / 38 20 / 15 0.65 kg h-1 0.30 kg h-1 32 kg / 70 lbs 36 kg / 79 lbs 57 dB(A) @ 50 Hz 0.55 kW 0.55 kW 0.75 kW 0.75 kW
2
m 3 h -1
10
170 (6.69)
-3
3 × 10 mbar / 1 x 10 mbar / 2.2 x 10-2 Torr 7.5 x 10-4 Torr 6.5 × 10-1 mbar / 1.5 × 10-2 mbar / 4.8 x 10-1 Torr 1.1 x 10-2 Torr NW25 Nozzle 15 mm external diameter removable from hole tapped ¾ inch BSP 0.5 bar gauge / 7 psig
4 x Ø9 (0.35) D
260 (10.24)
10 (0.39)
47 (1.85)
Inlet connection Outlet connection
-2
75 75 (2.95) (2.95)
18
39 (1.54)
with gas ballast
E1M18 E2M18 20.5 m3h-1 / 12.1 ft3min-1 25.0 m3h-1 / 14.7 ft3min-1 17.0 m3h-1 / 10 ft3min-1 20.4 m3h-1 / 12.1 ft3min-1
15 (0.59)
Displacement (swept volume) 50 Hz Displacement (swept volume) 60 Hz Speed (Pneurop 6602) 50 Hz Speed (Pneurop 6602) 60 Hz Ultimate vacuum (total pressure) without gas ballast
227.5 (8.96)
TECHNICAL DATA
10 (0.39)
C
E1M18 pump 200-230/380-415 V, 50 Hz, 3-ph or 200-230/460 V, 60 Hz, 3-ph 100/200 V, 50 Hz 1-ph or 100-105/200-210 V, 60 Hz 115/200-230 V, 50/60 Hz, 1-ph with IEC60320 connector fitted*† E2M18 pump 200-230/380-415 V, 50 Hz, 3-ph or 200-230/460 V, 60 Hz, 3-ph 100/200 V, 50 Hz, 1-ph or 100-105/200-210 V, 60 Hz 115/200-230 V, 50/60 Hz, 1-ph with IEC60320 connector fitted*† Supplied with: Ultragrade 19 oil, NW25 ‘ O’ ring and centering ring, lifting plate. * Use suitable cable for your country, see accessories. † Factory set to 230 V
Shop online at www.bocedwards.com
ORDERING NUMBER
A34310940 A34315904 A34317984 A36310940 A36315904 A36317984
SMALL PUMPS AND PUMPING SYSTEMS
60Hz 10
ORDERING INFORMATION SPARES
1 PAGE 20
ORDERING NUMBER
The clean and overhaul kit contains all of the springs, gaskets, seals and other components required for routine maintenance and whenever the pump is dismantled. Add a blade kit for a full service. Clean and overhaul kit A36301131 Blade kit E1M18 A34301041 E2M18 A36301020 NW25 centering ring and ‘ O’ ring C10514396 NW25 ‘ O’ ring (pack of five) H02124035 ACCESSORIES
NW25 to 28 mm bore tube adaptor EMF20 outlet mist filter ¾ inch to NW25 outlet adaptor 2 m electrical supply cable UK three-pin plug North European plug North America/Japan plug
ORDERING NUMBER
C10520201 A46229000 C10501414 A50505003 A50506003 A50507003
For electrical data, including recommended fuse ratings, see page 1-23. For other accessories, see page 1-23 to 1-27. For rotary pump oils, see page 13-43. For PFPE oil filled pumps and flameproof motored pumps contact BOC Edwards.
Shop online at www.bocedwards.com
E2M28 TWO STAGE ROTARY PUMP 32.2 m 3 h -1 , 19 ft 3 min -1 , 537 l min -1
10
1
1
ft 3 min -1
10
2
PAGE 21
1 10
0
2
-1
10
-4
10
1
-3
10
-2
10
-1
10
60 Hz without gas ballast
2
0
10
1
2
10
10
3
Torr
60 Hz with gas ballast
A B
170 (6.69)
E2M28
B
C
D
E
F
G
608 -
553 582 582
217 251 251
-
-
-
-
-1
10
10
10
-1
10
0
10
10
1
10
10
0
2
10
10
1
3
10
10
2
4
mbar
Pa
(Total Pressure)
1
50 Hz without gas ballast
2
43 (1.69)
A
A373-10-940 A373-15-904 A373-17-984
Supplied with: Ultragrade 19 oil, NW25 ‘ O’ ring and centering ring, lifting plate. * Use suitable cable for your country, see accessories. † Factory set to 230 V
2 0
-1
47 (1.85)
ORDERING NUMBER
E2M28 pump 200-230 V, 380-415 V, 50 Hz, 3-ph or 200-230 V, 460 V, 60 Hz, 3-ph 100/200 V, 50 Hz, 1-ph or 100-105/200-210 V, 60 Hz 115/200-230 V, 50/60 Hz, 1-ph with IEC60320 connector fitted*†
1
-2
39 (1.54)
NW25
PRODUCT DESCRIPTION
1
-3
25 (0.98)
241 (9.49) 180 (7.09)
E2M28, 50Hz 10
111 (4.37)
ORDERING INFORMATION
1.5 liter 1.2 liter Ultragrade 19
2
m 3 h -1
10
347 (13.66)
12 (0.47)
39 (1.54)
1 x 10-3 mbar / 7.5 x 10-4 Torr 1.5 × 10-2 mbar / 1.1 x 10-2 Torr NW25 flange Nozzle 15 mm external diameter removable from hole tapped ¾inch BSP 0.5 bar gauge / 7 psig 30 mbar / 23 Torr 0.7 kg h-1 40 kg (88 lb) 57 dB(A) @ 50 Hz 0.75 kW 0.90 kW
Maximum permitted pressure at outlet Maximum inlet pressure for water vapor Maximum water vapor pumping rate Weight Noise Motor power 50 Hz Motor power 60 Hz Oil capacity Maximum Minimum Recommended oil (supplied)
10
60
28 4 x Ø9 (0.35)
Inlet connection Outlet connection
10
60
(2.36) (2.36)
227 (8.94)
32.2 m3h-1 / 19 ft3min-1 38.9 m3h-1 / 22.3 ft3min-1 27.5 m3h-1 / 16.2 ft3min-1 33.0 m3h-1 / 19.5 ft3min-1
Displacement (swept volume) 50 Hz Displacement (swept volume) 60 Hz Speed (Pneurop 6602) 50 Hz Speed (Pneurop 6602) 60 Hz Ultimate vacuum (total pressure) without gas ballast with gas ballast
10 (0.39)
330 (12.99)
C
TECHNICAL DATA
25 (0.98)
227 (8.94)
3 (0.12)
50 Hz with gas ballast
Shop online at www.bocedwards.com
ORDERING NUMBER
A37310940 A37315904 A37317984
SMALL PUMPS AND PUMPING SYSTEMS
E2M30, 60Hz 10
ORDERING INFORMATION SPARES
1 PAGE 22
ORDERING NUMBER
The clean and overhaul kit contains all of the springs, gaskets, seals and other components required for routine maintenance and whenever the pump is dismantled. Add a blade kit for a full service. Clean and overhaul kit A37301131 Blade kit A37301134 NW25 centering ring and ‘ O’ ring C10514396 NW25 ‘ O’ ring (pack of five) H02124035 ACCESSORIES
MF30 outlet mist filter NW25 to 28 mm bore tube adaptor ¾ inch to NW25 outlet adaptor 2m electrical supply cable UK three-pin plug North European plug North America/Japan plug
ORDERING NUMBER
A46233000 C10520201 C10501414 A50505003 A50506003 A50507003
For electrical data, including recommended fuse ratings, see page 1-23. For other accessories, see page 1-23 to 1-27. For rotary pump oils, see page 13-43. For PFPE oil filled pumps and flameproof motored pumps contact BOC Edwards.
Shop online at www.bocedwards.com
ELECTRICAL DATA
SMALL PUMP ACCESSORIES
The table shows current data and suggests a suitable fuse rating. Starting current is drawn for less than one second and slow blow fuses should be used to prevent unnecessary rupture during starting. Pump outfits are rated for operation above 12°C. Pump starting at temperatures lower than 12°C will increase the current drawn due to the higher start torque required. This may cause the motor thermal overload to trip.
This diagram shows the accessories available for oil-sealed pumps. Refer to the following pages for details of each accessory. Note that the E-LAB2 pump is supplied with all required accessories. 4
5
6
Electrical supply Speedivac 2 220-240 V 1-ph 50 Hz 105-115 V 1-ph 50/60 Hz
SUGGESTED FUSE RATING (A)
3
7
50 Hz 60 Hz 50 Hz 60 Hz 2.2
17.2 4.8
10 10
24
1
2
E2M0.7 220-240 V 1-ph 50/60 Hz 100-120 V 1-ph 50/60 Hz
1.0 1.8
1.0 1.9
2.8 5.7
2.3 5.3
6 10
E2M1.5 220-240 V 1-ph 50/60 Hz 100-120 V 50/60 Hz
1.4 3.1
1.3 2.6
5.5 12.0
5.2 11.2
6 10
RV3 and RV5 220-240 V 1-ph 50 Hz 230-240 V 1-ph 60 Hz 110 V 1-ph 50 Hz 115-120 V 1-ph 60 Hz 200-220 V 3-ph 50 Hz 200-230 V 3-ph 60 Hz 380-415 V 3-ph 50 Hz 460 V 3-ph 60 Hz RV8 and RV12 220-240 V 1-ph 50 Hz 230-240 V 1-ph 60 Hz 110 V 1-ph 50 Hz 115-120 V 1-ph 60 Hz 200-220 V 3-ph 50 Hz 200-230 V 3-ph 60 Hz 380-415 V 3-ph 50 Hz 460 V 3-ph 60 Hz E1M18/E2M18 100 V 110-120 V 200-210 V 230 V 200-230 V 3-ph 380-415 V 3-ph 460 V 3-ph E2M28 100 V 110-120 V 200-210 V 230 V 200-230 V 3-ph 380-415 V 3-ph 460 V 3-ph
2.4
15.6 2.2
4.6
15.2 29.4
4.4 1.7
31.5 10.2
1.7 1.0
10.2 5.7
1.0 4.0
7.0 18.0
3.6 7.8
18.0 34.0
7.2 2.5
34.0 14.0
2.9 1.5
12 9.0
1.5 12 11 6 4.6
10 5.5 5 2.3
1.9
8.7 88 42 44 33 10.2
1.6
12 6 6
32 44 33 15.9 10.6
80 12 6.5 6.5 3.9
2.3
27 27
50 32 32 22
14.3 2.3
14.6
13
5 5 10 10 2.5 2.5 2.5 2.5
OIL
10
5 5 13 13 4 4 2.5 2.5
OIL
9 8
30 30 15 15 10 6 6
30 30 15 15 16 10 10
11
12
1
Outlet mist filter1
8
Vibration isolators
2
Oil return kit2
9
Oil drain kit3
3
Small volume inlet liquid catchpot
10 OB20 oil box purge adaptor
4
ITO20K inlet liquid catchpot
11 Oil change reminder card
5
ITC20K inlet chemical trap
12 RV gas ballast adaptor4
6
ITF20K inlet dust filter
13 EBV20 solenoid operated gas ballast
7
FL20K foreline trap
1
EMF filter shown
2 3 4 5
RV adjustable gas ballast oil return kit shown RV pump extension kit shown See page 1-8, not required for EM pumps See page 2-29.
valve5
For accessories for D-LAB pumps, see page 1-32.
Minimum starting voltage is 10% below lowest nominal voltage. These fuse ratings are for indication only. The relevant instruction manual should be checked before use.
Shop online at www.bocedwards.com
SMALL PUMPS AND PUMPING SYSTEMS
Three-phase motors should be protected by a starter consisting of a suitably rated contactor and thermal overload. The trip current regulator on the thermal overload should be set according to the starter manufacturer's instructions. FULL LOAD START CURRENT (A) CURRENT (A)
1 PAGE 23
MF30 filters
OUTLET MIST FILTERS
Ø150 (5.91)
308 (12.13)
248 (9.76)
NW25
296 (11.65)
31 (1.22)
83 (3.27)
1 PAGE 24
ORDERING INFORMATION PRODUCT DESCRIPTION
Mist filters capture oil mist from the outlet of pumps, which would otherwise be ejected into the atmosphere. This may happen when you use gas ballast or when you pump high gas throughputs. You can also return oil trapped in the mist filter back to the pump, although you must ensure that the process gases will not contaminate the pump or pump oil. Benefits of the mist filter include: • Protection from oil mist emissions as required by COSHH and health and safety regulations • Use of optional oil return kits results in reduced oil level maintenance and savings in pump oil • If the oil element becomes blocked, an integral pressure relief valve opens EMF filters The EMF3, EMF10 and EMF20 mist filters are suitable for all small rotary vane pumps up to E2M18. They are very efficient at 99.999% DOP test and are also azide proof. The white bottom half of the body is semi-transparent, allowing the oil level to be monitored. The EMF filters have a unique odor element which neutralizes the smell of oil mist. MF30 filter The MF30 is suitable for E2M28 pumps. It is very efficient at 99.85% DOP test. You can monitor the oil level through the sight-glass provided. Oil return kits These conserve the pump oil, by returning the oil trapped in the mist filter to the pump. The gas ballast oil return kit, for example, allows extended operation of the pump with gas ballast.
EMF filters
Model Model Model Model
EMF3 mist filter (0.315 kg)1 EMF10 mist filter (0.500 kg)2 EMF20 mist filter (0.700 kg)2 MF30 mist filter (1.30 kg)3
ORDERING NUMBER
A46220000 A46226000 A46229000 A46233000
1 Supplied with NW10 clamp, centering ring and ‘ O’ ring, NW10 to £/8 inch BSP adaptor. 2 Supplied with NW25 clamp, centering ring and ‘ O’ ring, NW25 to £/4 inch BSP adaptor. 3 Supplied with NW25 elbow, NW25 clamp, NW25 to £/4 inch BSP adapter and NW25 Co-Seal. ACCESSORIES
Clean application oil return kit (RV, Speedivac 2 to E2M1.5) Adjustable gas ballast oil return kit (RV) Clean application oil return kit (E1M18 to E2M28) SPARES
Odor element (pack of 5) EMF3 EMF10 EMF20 Oil element EMF3 EMF10 EMF20 MF30 Body seal EMF3 EMF10 EMF20
ORDERING NUMBER
A50419000 A50523000 A50420000 ORDERING NUMBER
A22304081 A22304079 A22304077 A22304197 A22304198 A22304199 A22304057 A27159538 A27159535 A27159534
OIL RETURN KITS A EMF3
A
EMF10 EMF20 FLOW
B SQUARE 128mm / 82 mm / 5.03 in 3.22 in 171 mm / 97 mm / 6.73 in 3.81 in 191 mm / 118.4 / 7.51 in 4.66 in
INLET/ OUTLET NW10 NW25 NW25
ORDERING INFORMATION PRODUCT DESCRIPTION
Clean application oil return kit (RV, Speedivac 2 to E2M0.7, E2M1.5) Adjustable gas ballast oil return kit (RV) Clean application oil return kit (E1M18 to E2M28)
B
Shop online at www.bocedwards.com
ORDERING NUMBER
A50419000 A50523000 A50420000
INLET LIQUID CATCHPOTS
ITF20K INLET DUST FILTER The ITF inlet dust filters prevent the entry of dust particles into the pump. The impedance of a clean filter reduces the pumping speed of a 20 m3h-1 pump by about 20% at 1 mbar and 25% at 10 mbar. Depending on your application, you can normally clean the filter element with a vacuum cleaner or a clean air blast, and then re-use the element.
ORDERING INFORMATION PRODUCT DESCRIPTION
ORDERING NUMBER
ITF20K inlet dust filter (3.4) kg ITF20K element and gasket kit (0.3 kg) Dimensions ITO20K, ITC20K and ITF20K
68.5 (2.70)
124 (4.88)
106 (4.17)
205 (8.07)
Ø171 (6.73)
143 (5.63)
These catchpots minimize the entry of condensable vapors into the pump. Benefits of the catchpots include: • Capture condensable vapors, which would otherwise condense in the pipelines or in the pump • Prevents froth or spray from the process from carrying over to the pump • Corrosion-resistant body • Visual indication of trapped liquid level • Hand-tightened drain plug, for easy drainage
A44215000 A44201800
NW10
45 ˚
NW25
ORDERING INFORMATION PRODUCT DESCRIPTION
ORDERING NUMBER
ITO20K inlet catchpot, 1.84 liters capacity, weight 3.2 kg Small volume inlet catchpot 0.1 liter capacity, weight 0.3 kg Both supplied with NW25 clamp, centering ring and ‘ O’ ring.
A44110000 A44105000
EBV GAS BALLAST CONTROL VALVES Fit the EBV 20 valve to allow remote operation of the pump’s gas ballast control.
ORDERING INFORMATION PRODUCT DESCRIPTION
ITC20K INLET CHEMICAL TRAPS The ITC series of chemical traps provides the following benefits: • Protection against various aggressive vapors, which may attack the pump or pump oil • Prevent high molecular weight vapors (such as might arise in a resin treatment plant), from reaching the pump. These vapors could cause lacquering or clogging • The standard sorbent (activated charcoal), has relatively high trapping properties (absorbs around 25% of its own weight), even when large amounts of water vapor are being pumped • When filled with activated alumina on two-stage pumps, backstreaming of pump oil can be controlled • See also ITO catchpots for design advantages of the body
ORDERING NUMBER
ITC20K inlet chemical trap charcoal charge 0.4 kg, weight 3.5 kg
A44410000
Sorbent charge not supplied. Supplied with NW25 clamp, centering ring and ‘ O’ ring. SPARES
0.5 kg activated charcoal 3 kg activated charcoal 0.45 kg activated alumina 0.2 kg activated alumina
ORDERING NUMBER
A50006930 A50502000 A50006003
POWER CABLES Select the correct cable for your product and country.
Power cables for RV pumps and XDS5, XDS5C, XDS10 and XDS10C pumps Pump end connector is EN60320 C13.
ORDERING INFORMATION PRODUCT DESCRIPTION
ORDERING INFORMATION PRODUCT DESCRIPTION
EBV20 (0.5 kg) 220 - 240 V 50/60 Hz Suits the E2M0.7 to E2M28 including RV. For RV pump the Gas Ballast adapter is required For the E1M18/E2M28 an Adapter is required
UK, three pin plug, 2 m North European plug, 2 m North America/Japan plug, 2 m No plug, 2 m
ORDERING NUMBER
H12205001 H12205002 H02600050 H02600056
Shop online at www.bocedwards.com
ORDERING NUMBER
A50505000 A50506000 A50507000 A50508000
SMALL PUMPS AND PUMPING SYSTEMS
The benefits of the ITF filters include: • Thick aluminum casting, to withstand abrasion • Tangential entry port, to promote centrifugal separation of dust particles • Filter efficiency better than 96% (tested to BS2831, dust number 2).
1 PAGE 25
Power cables for EM18, 28 and XDS35i pumps
VIBRATION ISOLATORS
Pump end connector is IEC60320 C19.
PRODUCT DESCRIPTION
ORDERING NUMBER
UK, three pin plug, 2 m North European plug, 2 m North America/Japan plug, 2 m No plug, 2 m
A50505003 A50506003 A50507003 A50508003
You may need to fit vibration isolators to your pump if you mount it into a frame or a system, if the mounting points are not level or if you need to minimize the transmission of vibration and noise in your application. You must fit flexible bellows or other flexible pipes to the pump inlet and outlet. The height of the isolators reduces by about 1 mm when the pump is fitted. SPEEDIVAC 2
E2M0.7, E2M1.5 Ø22 (0.97)
Ø12.7 (0.5)
FL20K FORELINE TRAP
3.5 (0.14)
12.7 (0.5)
18 (0.71)
M5
19 (0.75)
61 (2.40)
37 (1.46)
12.7 (0.5)
50 (1.97)
M5
2 x Ø5 (0.20)
RV pumps, E1M18/E2M18, E2M28
30 (1.18)
The FL20K is most useful with two-stage rotary pumps, operating below 1 mbar. To maximize sorbent life, install the FL20K near the vacuum system. In common with other types of sorbent, activated alumina absorbs water. This does not affect the oil vapor trapping properties but may tend to prolong the roughing time on successive pump downs. To minimize vapor absorption, we recommend you fit a valved by-pass line.
41 (1.61)
Ø25
The FL20K foreline trap has been developed for use in clean pumping systems, to prevent the back-migration of rotary pump oil mist into the system. The activated alumina sorbent has the following benefits: • Exceptional trapping properties for oil mist (99.7%) • A very long life before it is saturated • Can be rejuvenated by baking the basket containing the sorbent for 2 hours at 250 °C - 300 °C.
5 (0.20)
(0.98)
74 (2.91) 60 (2.36)
2 x Ø6 (0.24)
The trap body is made of aluminum and is fitted with a removable basket containing the sorbent.
ORDERING INFORMATION 6.5 (0.26)
PRODUCT DESCRIPTION
Vibration isolators Speedivac 2 (0.1 kg) E2M0.7, E2M1.5 (0.3 kg) RV, E1M/E2M18, XDS (0.45 kg) E2M28 (0.45 kg)
50 (1.97)
Ø82.5 (3.25)
1 PAGE 26
ORDERING INFORMATION
50 (1.97)
NW25
130 (5.12)
ORDERING INFORMATION PRODUCT DESCRIPTION
FL20K foreline trap (Supplied with 0.2 kg sorbent charge) Sorbent charge 0.1 kg, weight 1.0 kg By-pass valve SPARES
0.45 kg activated alumina 0.2 kg activated alumina
ORDERING NUMBER
A13305000
C07902000 ORDERING NUMBER
H02600050 H02600056 Shop online at www.bocedwards.com
ORDERING NUMBER
A24801403 A24801407 A24801404 A24801412
WATER JET PUMP 0.23 m 3 h -1
OIL BOX DRAIN KITS Two kits are available: • RV easy oil box drain kit. This kit includes an oil drain extension tube for use when the oil is gravity drained. • Fits E2M0.7, E2M1.5, RV, E1M18, E2M18, E2M28. • ODP20, for use with the E1M18, E2M18 and E2M28 pumps. This accessory provides alternative methods for draining oil where access to the pump drain plug is difficult, or where there is no room for a receptacle under the drain outlet. The pack includes an oil drain extension tube for use when oil is gravity drained, and a pressure drain device with which the oil can be discharged at a high level.
1 PAGE 27
PRODUCT DESCRIPTION
ORDERING NUMBER
RV easy oil box drain kit ODP20 oil box drain kit
A50503000 A50002000
OB20 OIL BOX PURGE ADAPTOR This stainless steel adaptor enables a flow of dry inert gas to be introduced into the oil box to provide large scale dilution of process gases which cannot be dealt with sufficiently by the standard gas ballast facility. The adaptor replaces the oil filler plug, on the RV and E1M18/E2M18 pumps only.
ORDERING INFORMATION PRODUCT DESCRIPTION
OB20 oil box purge adaptor
ORDERING NUMBER
Fits laboratory tap and ordinary water supply for simplest production of rough vacuum for distillation, filtration, aeration etc. An integral nonreturn valve prevents system flooding from fluctuating water pressures.
A50034000 Material of construction
OIL CHANGE REMINDER TAG
Recommended water pressure Operational water temperature Pumping speed (air) Ultimate vacuum Time to evacuate volume of 5 liters down to 60 mbar Water consumption Connections Water Vacuum Drain Weight Size
Corrosion resistant plastic equivalent to stainless steel 1.4 bar / 20 lbs in-1 15°C / 59°C 0.23 m3h-1 - 3.9 l min-1 16 - 19 mbar / 12-14.25 Torr 3 min approx 625 l h-1 / 2.75 G min-1 12 mm tubing riffled to suit 7 mm bore tubing £/8 inch (9.5 mm) tubing 34 g 60W x 110L / 2.5 in x 4.3 in
ORDERING INFORMATION PRODUCT DESCRIPTION
Water jet pump Fluoroelastomer ball/pin assembly for non-return valve
The oil change reminder tag is a useful reminder for users to change the oil when it starts to go brown. Brown oil indicates that the oil is contaminated or degraded, and must be changed to prevent mechanical wear or failure of the pump. Tie the tag onto the pump exhaust so that it hangs over the oil box.
ORDERING INFORMATION PRODUCT DESCRIPTION
Oil change reminder tag (pack of 10)
ORDERING NUMBER
A20003017
Shop online at www.bocedwards.com
ORDERING NUMBER
C41001000 C03901010
SMALL PUMPS AND PUMPING SYSTEMS
ORDERING INFORMATION
XDS5 AND XDS10 SCROLL PUMPS
1
TECHNICAL DATA Displacement 50 Hz operation
PAGE 28
60 Hz operation Peak pumping speed 50 Hz operation
60 Hz operation
The XDS pumps are an innovative new design which use a patented bearing shield to isolate the vacuum environment from all forms of lubricant, not only making it totally dry, but hermetically sealed. The shield also protects the bearing from any process vapors. Adjustable gas ballast allows vapor to be handled and opens up the range of applications to many that were previously unsuited to scroll pumps. The XDS-C range are designed for pumping condensable vapors and use materials selected for a wide range of laboratory wet chemistry applications.
APPLICATIONS XDS • Scanning electron microscopes • Ion implanters (beamline and end stations) • General clean pumping applications • Sputtering • Turbo pump backing • Rare gas re-circulation XDS-C Gel drying Rotary evaporation Centrifugal concentration Vacuum ovens Glove boxes
XDS10/10C
5.7 m3h-1 / 3.4 ft3min-1 6.7 m3h-1 / 4.0 ft3min-1
11.3 m3h-1 / 6.7 ft3min-1 13.4 m3h-1 / 7.9 ft3min-1
4.8 m3h-1 2.8 ft3min-1
9.3 m3h-1 5.5 ft3min-1
6.0 m3h-1 3.5 ft3min-1
11.1 m3h-1 6.5 ft3min-1
7 x 10-2 / 5.3 x 10-2 6 x 10-2 / 4.5 x 10-2 9 x 10-1 / 6.8 x 10-2 7 x 10-1 / 5.3 x 10-1 NW25 NW25 1.0 bar gauge 0.5 bar gauge 50 mbar / 38 Torr
Maximum water vapor pumping rate Gas ballast low flow Gas ballast high flow Motor power Motor voltages 1-phase 50 Hz 1-phase 60 Hz 3-phase 50 Hz 3-phase 60 Hz Operating temperature range Weight Noise Vibration Leak tightness (static)
35 mbar / 23 Torr 70 g h-1 >200 g h-1 0.3 kW
110 V or 220-240 V 115-120 V or 230-240 V 200-220 V or 380-415 V 200-230 V or 460 V 5 - 40 °C 23 kg (51 lb) 24.5 kg (54 lb) 55 dB (A) @ 50 Hz <1.5 mms-1 (rms) <10-6 mbar I s-1
12 5 10 6 1 8
m3 h -1
• • • • •
Ultimate vacuum (total pressure) "S" Scientific 50 Hz 60 Hz "C" Chemical 50 Hz 60 Hz Inlet connection Outlet connection Maximum allowed outlet pressure Maximum allowed inlet and gas ballast pressure Maximum water vapor inlet pressure
XDS5/5C
2 7
6 3 4 8
4
2
XDS - XDS-C 0 10 -2
10
10 0
10 1
-1
10
0
10 2
1
10 2
10 3 mbar
10 3
10 4
10 5 Pa
10
Total Pressure
1
60 Hz XDS10
2
50 Hz XDS10
3
60 Hz XDS5
4
50 Hz XDS5
5
60 Hz XDS10-C
6
50 Hz XDS10-C
7
60 Hz XDS5-C
8
50 Hz XDS5-C
Shop online at www.bocedwards.com
ORDERING INFORMATION
7 5 6
PRODUCT DESCRIPTION
6
1 5 ft 3 min -1
2 4 7 3 3 8 4 1
XDS - XDS-C 0 10 -2
10 -1
10 0
10 1
10 2
10 3 Torr
1
60 Hz XDS10
2
50 Hz XDS10
3
60 Hz XDS5
4
50 Hz XDS5
5
60 Hz XDS10-C
6
50 Hz XDS10-C
7
60 Hz XDS5-C
8
50 Hz XDS5-C
135 (5.32)
427 (16.81)
55
210 (8.27)
288 (11.34)
(2.17)
230 (9.06)
A
Dimension reference A: XDS10 = 315 mm XDS5 = 297 mm
A72401906 A72401903 A72401904 Contact BOC Edwards
115/230 V (set to 115 V) for North America* 115/230 V (set to 230 V) for Europe & UK* 100/200 V (set to 200 V) for Japan
A72501906 A72501903 A72501904
115/230 V (set to 115 V) for North America* 115/230 V (set to 230 V) for Europe & UK* 100/200 V (set to 200 V) for Japan* 200/380/415/460 V set to high volts
A72601906 A72601903 A72601904 Contact BOC Edwards
115/230 V (set to 115 V) for North America* 115/230 V (set to 230 V) for Europe & UK* 100/200 V (set to 200 V) for Japan
A72701906 A72701903 A72701904
4 x Ã&#x2DC;9 (0.35)
(5.24)
SPARES
120 (4.72)
(1.93)
115/230 V (set to 115 V) for North America* 115/230 V (set to 230 V) for Europe & UK* 100/200 V (set to 200 V) for Japan* 200/380/415/460 V set to high volts
* Use suitable cable for your country. 133
49
ORDERING NUMBER
249 (9.80)
ORDERING NUMBER
Tip seal kit
A72601805
ACCESSORIES
ORDERING NUMBER
Gas ballast adaptor Exhaust silencer Silencer spares kit 2 m electrical supply cable UK, three-pin plug North European plug North America/Japan plug No plug
Shop online at www.bocedwards.com
A50626000 A50597000 A50597800 A50505000 A50506000 A50507000 A50508000
1 PAGE 29
SMALL PUMPS AND PUMPING SYSTEMS
2
XDS5 1-phase 1-phase 1-phase 3-phase XDS5C 1-phase 1-phase 1-phase XDS10 1-phase 1-phase 1-phase 3-phase XDS10C 1-phase 1-phase 1-phase
NEW Operating temperature range Weight Noise Vibration Leak tightness (static)
XDS35i SCROLL PUMP
1
5 - 40 °C / 50 to 140 °F 48 kg (105 lb) 57 dB (A) <4.5 mms <10-6 mbar I s-1 7 x 10-7 Torr I s-1
PAGE 30 40 35 30
m 3 h-1
25 20 15 10 5
XDD1
0 10 -3
The XDS35i pump has the same innovative patented bearing shield design as the XDS5 and XDS10. This isolates the vacuum environment from all forms of lubricant, not only making it totally dry but hermetically sealed. The shield also protects the bearing from any process vapors. Adjustable gas ballast allows vapor to be handled and opens up the range of applications to many that were previously unsuited to scroll pumps.
10
10 -2
-1
10
0
10 -1
10
0
10
1
10
2
10
3
mbar
1
10
2
10
3
10
4
10
5
Pa
10
333 (13.11) 476 (18.74)
Features & benefits • Totally dry, lubricant free vacuum - No oils or greases of any kind giving cleaner, more repeatable processes with less servicing - No bearing or shaft seals in vacuum, no bearing purges required • Peak pumping speed of 35 m3h-1 on 50 or 60 Hz supply • One model with world-wide voltage compatibility - 100 to 120 V 50/60 Hz - 200 to 230 V 50/60 Hz • Ultimate pressure 0.01 mbar (8 mTorr) • 3 position gas ballast selector allows handling of >200 g h-1 water vapor
2
50 (1.97)
388 (15.28)
397 (15.63)
1
224 (8.82)
212 (8.35)
An innovation on this pump is the use of an inverter to control the motor characteristics. This ensures the pump always runs at optimum speed and allows the user to control the pump remotely.
180 (7.09)
A
290 (11.42) B
353 (13.90) A
Centre line of on/off switch, 150 (5.91)
B
Centre line of phase socket, 247.5 (9.74)
1
Inlet flange NW40
2
Outlet port NW25
ORDERING INFORMATION PRODUCT DESCRIPTION
APPLICATIONS • • • • • • •
XDS35i† 100-120/200-230 V, 50/60 Hz with IEC60320 connector fitted*
Mass spectroscopy Scanning electron microscopes Beam lines and end stations Clean pumping applications Turbo pump backing Rare gas circulation Load lock chambers
A73001983
* Use suitable cable for your country. † Factory set to 230 V SPARES
TECHNICAL DATA Displacement 50 Hz or 60 Hz operation Peak pumping speed 50 Hz or 60 Hz operation Ultimate vacuum (total pressure) Inlet connection Outlet connection Maximum allowed outlet pressure Maximum allowed inlet pressure Maximum water vapor inlet pressure Maximum water vapor pumping rate Gas ballast low flow Gas ballast high flow Motor power Motor voltage and frequency
ORDERING NUMBER
43 m3h-1 / 25 ft3min-1 35 m3h-1 / 21 ft3min-1 0.01 mbar / 0.008 Torr NW40 NW25 1.0 bar gauge 0.5 bar gauge 50 mbar / 38 Torr
ORDERING NUMBER
Tip seal kit
A73001801
ACCESSORIES
ORDERING NUMBER
Exhaust silencer Silencer spares kit 2 m electrical supply cable UK, three-pin plug North European plug North America/Japan No plug
70 g h-1 240 g h-1 0.6 kW 100-120/200-230 V, 50/60 Hz
Shop online at www.bocedwards.com
A50597001 A50597801 A50505003 A50506003 A50507003 A50508003
ESDP12 SCROLL PUMP
10
8
1
1 2
ft 3 min -1
6
PAGE 31
4
2
10 -1
10 0
10 1
10 2
10 3
Torr
1
60 Hz
2
50 Hz
252 (9.92)
400 (15.75)
122 (4.80)
96 (3.78)
336 (13.23)
The ESDP12 is not suitable for applications where vapor pumping is required.
APPLICATIONS
136 (5.35)
TECHNICAL DATA
180 (7.09)
Displacement (swept volume) 50 Hz 60 Hz Peak pumping speed 50 Hz 60 Hz Ultimate vacuum (total pressure) Inlet connection Outlet connection Motor power Electrical supply, 1-phase 50 Hz 60 Hz Enclosure rating Operating temperature range Weight Noise level at ultimate (at 1 metre) Vibration Leak tightness (static)
12.5 m3h-1 / 7.3 ft3min-1 15 m3h-1 / 8.8 ft3min-1 1.6 10-2 mbar / 1 x 10-2 Torr NW25 NW16 0.4 kW 200 / 230 V 110 / 115 V IP44 5 - 40 ºC / 41-104 °F 25 kg / 55 lbs 58 dB(A) 1.5 mms-1 10-4 mbar I s-1
PRODUCT DESCRIPTION
ESDP12 SPARES
Tip seals kit Minor service kit Major service kit Major service tool kit
14 12
m3 h -1
2
10 8 6 4 2
ESDP12
0 10 -2
10 -1
10 0
10 1
10 2
10 3 mbar
10 0
10 1
10 2
10 3
10 4
10 5 Pa
(Total Pressure)
60 Hz
2
121 (4.76) 101 (3.98)
130 (5.12)
4 x M10
170 (6.69)
ORDERING INFORMATION
18
1
52 (2.05)
15 m3h-1 / 8.8 ft3min-1 18 m3h-1 / 10.6 ft3min-1
16
1
38 (1.50)
• Clean and dry turbomolecular pump backing • High energy physics • Leak detection
50 Hz
Shop online at www.bocedwards.com
ORDERING NUMBER
A71002909 ORDERING NUMBER
A71002026 A71002820 A71002800 A71002025
SMALL PUMPS AND PUMPING SYSTEMS
ESDP12 0 10 -2
from a chiller or circulator (not supplied) to be used to control the condenser temperature.
D-LAB DIAPHRAGM PUMP
Vacuum controller
1
The vacuum controller provides control of the system pressure and stops the pump when a pre-set pressure is reached. This saves power and extends the service life of the diaphragm. Typically, the controller is used on a system that incorporates the baseplate, condenser and separator.
PAGE 32
Gas-ballast control valve The use of gas-ballast helps to prevent the condensation of vapors inside the pump. The valve control is on/off, at a fixed flowrate.
TECHNICAL DATA Pumping speed (air) 10-100, 10-8 20-100, 20-8 34-100, 34-8 Ultimate vacuum 10-100, 20-100, 34-100 50 Hz 10-100, 20-100, 34-100 60 Hz 10-8, 20-8, 34-8 50 Hz 10-8, 20-8, 34-8 60 Hz Inlet and outlet connection
APPLICATIONS • • • • •
Rotary evaporation Gel drying Vacuum desiccation Vacuum filtration Vacuum degassing
• • • • •
Vacuum impregnation Water-jet pump replacement Gas transfer Medium vacuum applications Oil-free pumping
The D-LAB membrane pumps with their chemically resistant Teflon heads, diaphragms and Kalrez® valves, offer the chemical or pharmaceutical laboratory user a wide range of choice, either used as stand-alone pumps or as part of a sophisticated system. The one head, 100 mbar / 75 Torr ultimate vacuum pumps are suitable for use with drying equipment or for replacing water-jet pumps. The two head, 8 mbar / 6 Torr ultimate vacuum pumps are suitable for rotary evaporation, gas transfer and a wide range of medium vacuum applications.
System options The pumps are designed so that they can be upgraded by the addition of a range of accessories. The accessories are supplied with all the required connections and no special tools are needed to fit them.
0.6 m3h-1, 10 l min-1 1.2 m3h-1, 20 l min-1 2 m3h-1, 34 l min-1 100 mbar 75 mbar 8 mbar 6 mbar Riffled nozzle, suitable for 9 mm i.d. hose 1 bar
Maximum inlet pressure Motor power and current 10-100, 110 V 60 Hz 10-100, 220-240 V 50 Hz 20-100, 110 V 60 Hz 20-100, 220-240 V 50 Hz 34-100, 110 V 60 Hz 34-100, 220-240 V 50 Hz 10-8, 110 V 60 Hz 10-8, 220-240 V 50 Hz 20-8, 110 V 60 Hz 20-8, 220-240 V 50 Hz 34-8, 110 V 60 Hz 34-8, 220-240 V 50 Hz Enclosure rating Operating temperature Weight 10-100 20-100 34-100 10-8 20-8 34-8
The modular accessories are: • Baseplate • Vacuum controller • Separator • Gas-ballast control valve • Condenser
110 W, 1.3 A 100 W, 0.6 A 145 W, 1.9 A 130 W, 0.9 A 220 W, 3.2 A 180 W, 1.4 A 110 W, 1.3 A 90 W, 0.6 A 130 W, 1.2 A 120 W, 0.9 A 250 W, 3.2 A 200 W, 1.5 A IP44 5 - 40 ºC 5.8 kg / 12.8 lbs 7.1 kg / 15.6 lbs 10.3 kg / 22.7 lbs 6.9 kg / 15.2 lbs 9.3 kg / 20.5 lbs 12.6 kg / 27.7 lbs
2.2 2.0 1.8 1.6 1.4
The baseplate allows the pump and accessories to be mounted on to a common frame.
m 3 h -1
Baseplate
1
1.2 1.0 2
0.8
Separator
0.6
When used on the exhaust side, solvent droplets are separated from the process gas and collected. When used on the inlet side, the separator may be used to collect particles in the process gas, so assisting pump reliability.
0.4
3
D-LAB, 50Hz
0.2 0 0
100
200
300
400
500
600
700
800
900
0
1
2
3
4
5
6
7
8
9
1000 mbar
Condenser The condenser separates and collects condensable materials from the exhaust side of the pump. The condensed materials are collected in an easily removed glass flask. Connections are available to allow cooling fluid
10
(Total Pressure)
1
D-LAB 34-100
Kalrez® is a registered trademark of Dupont Dow Elastomers
Shop online at www.bocedwards.com
2
D-LAB 20-100
3
D-LAB 10-100
4
10 Pa
One head pumps
1.3
A
1.2
B
D
1.1 1.0
1
0.9 ft 3 min -1
0.8 0.7
PAGE 33
C
1
0.6 2
0.5
3
0.3
E
0.2
D-LAB, 60Hz
0.1 0 108
0
1
217
D-LAB 34-100
325
2
434
541
D-LAB 20-100
649
3
760 Torr
D-LAB 10-100
2.2 2.0
Two head pumps
1.8 1.6
F
m 3 h -1
1.4 1
1.2 1.0 0.8
2
0.6 3
0.4
D-LAB, 50Hz
0.2 0 0
100
200
300
400
500
600
700
800
900
0
1
2
3
4
5
6
7
8
9
1000 mbar
4
10 10 Pa
(Total Pressure)
1
D-LAB 34-8
2
D-LAB 20-8
3
D-LAB 10-8
1.3 1.2
Dimensions in mm D-LAB
A
B
C
D
E
F
10-100 20-100 34-100 10-8 20-8 34-8
255 268 296 288 312 341
50 60 60 53 59 62
182 204 222 184 204 222
144 157 172 -
98 110 122 98 110 122
140 153 169
1.1 1.0
ORDERING INFORMATION
0.9 ft 3 min -1
0.8
PRODUCT DESCRIPTION
1
0.7 0.6 0.5
2
0.4 3
0.3 0.2
D-LAB, 60Hz
0.1 0 0
1
108
D-LAB 34-8
217
325
2
434
D-LAB 20-8
541
3
649
D-LAB 10-8
760 Torr
D-LAB 10-100 110 V 1-phase 60 Hz 220-240 V 1-phase 50 Hz D-LAB 20-100 110 V 1-phase 60 Hz 220-240 V 1-phase 50 Hz D-LAB 34-100 110 V 1-phase 60 Hz 220-240 V 1-phase 50 Hz D-LAB 10-8 110 V 1-phase 60 Hz 220-240 V 1-phase 50 Hz D-LAB 20-8 110 V 1-phase 60 Hz 220-240 V 1-phase 50 Hz D-LAB 34-8 110 V 1-phase 60 Hz 220-240 V 1-phase 50 Hz Baseplate D-LAB 10-100, 20-100, 10-8 and 20-8 D-LAB 34-100 and 34-8 Separator1 Condenser1
Shop online at www.bocedwards.com
ORDERING NUMBER
A48015941 A48015960 A48017941 A48017960 A48021941 A48021960 A48016941 A48016960 A48018941 A48018960 A48022941 A48022960 A48015134 A48021134 A48015136 A48015137
SMALL PUMPS AND PUMPING SYSTEMS
0.4
ORDERING INFORMATION PRODUCT DESCRIPTION
1 PAGE 34
ORDERING NUMBER
Gas-ballast control valve D-LAB 10-100, 10-8 A48015135 D-LAB 20-100, 34-100, 20-8 and 34-8 A48017135 Vacuum controller1 220-240V 50Hz A48015138 100-110V 50/60 Hz A48015139 Service kit, one head pumps (1 diaphragm, 2 sealing rings, 2 valve plates) D-LAB 10-100 A48015815 D-LAB 20-100 A48017815 D-LAB 34-100 A48021815 Service kit, two head pumps (2 diaphragms, 4 sealing rings, 4 valve plates) D-LAB 10-8 A48016815 D-LAB 20-8 A48018815 D-LAB 34-8 A48022815 Electrical supply cable, with IEC socket (order one of these cables for 220-240 V supply) UK three pin plug A50505000 North European plug A50506000 No plug A50508000 1 Supplied with fittings for attachment to the baseplate 110 V pumps are supplied with USA plug; 220-240 V pumps are supplied with IEC plug. Other voltage pumps and controllers are available on request.
Shop online at www.bocedwards.com
XDD1 DIAPHRAGM PUMP
APPLICATIONS RGA Mass spectrometers Cryostat and Dewar evacuation Ion pump evacuation Surface science UHV Leak detection General R & D
1 PAGE 35
SMALL PUMPS AND PUMPING SYSTEMS
• • • • • • • •
TECHNICAL DATA
24 V d.c. and a.c. voltage variants The BOC Edwards XDD1 diaphragm pumps are used for backing small compound turbo-molecular pumps in clean, high vacuum applications. They comply with EN61010 and EN1012, and are designed to be free standing bench tops units. -8
A typical ultimate pressure of better than 5 x 10 mbar can be achieved when using an XDD1 to back a 70 l s-1 compound turbo-molecular pump. The 24 V version is designed to provide a complete pumping package using the BOC Edwards Turbo and Instrument Controller (TIC). Two versions of the XDD1 are available. The a.c. voltage motor can be used on worldwide supplies ranging from 100 to 115 V, and 200 to 230 V. The pump has both an on/off and voltage changeover switch. The power is connected through a standard EN60320 socket. The d.c. voltage motor runs on 24 V via a 15 pin DIN connector. By selecting the appropriate mode the pump speed can be controlled by the user to provide variable pumping speed. This version is suited to the customer who is building their own a system.
Pumping Speed 50 Hz a.c. 60 Hz a.c. 600 rpm d.c. 2200 rpm d.c. Ultimate vacuum (typical) a.c. d.c. Ambient temperature limit a.c. d.c. Inlet connection a.c. d.c. Exhaust connection a.c. d.c. Maximum allowed inlet pressure a.c. d.c. Motor power a.c. d.c. Weight a.c. d.c.
1.2 m3h-1 1.5 m3h-1 0.6 m3h-1 1.6 m3h-1 <2 mbar <2 mbar 10 to 40 °C 10 to 40 °C NW16 NW16 See note 1 See note 1 1 bar Abs 1 bar Abs 80 W 64 W 6.5 kg 4.1 kg
Notes 1.
The pump is fitted with a silencer. This can be removed and an exhaust line connected with a 1/8" BSP fitting.
Features & benefits
2.
Pumps are not supplied with connection cables. A suitable cable should be ordered with the pump. See accessories section below.
Dry Pumping • No oil disposal issues • Oil free turbomolecular backing pump
d.c. variant 1.80
Compact • Lightweight • Small footprint
1.60 1.40 1
m 3 h-1
1.20
Two versions • Worldwide a.c. voltage • On/off switch • EN 60320 connector • 24 V d.c. • BOC Edwards Turbo and Instrument Controller (TIC) compatible • Low power
1.00 0.80 2
0.60 0.40 0.20
XDD1
0.00 10
10
1
0
2
2000 rpm
Shop online at www.bocedwards.com
10
1
10
3
2
700 rpm
10
2
10
3
mbar
10
4
10
5
Pa
a.c. variant
ORDERING INFORMATION
1.80
PRODUCT DESCRIPTION
1.60
1
1
m 3 h-1
1.20 1.00
0.60
ACCESSORIES
0.40 0.20 0.00 10
10
XDD1 0
10
1
10
2
10
3
mbar
2
10
3
10
4
10
5
Pa
1
60 Hz
2
50 Hz
XDD1 a.c. version† UK, three pin plug, 3A (the pump connector is an EN60320 C13 connector) North European plug USA plug No plug †
1
215
d.c. version m XDD extension cable m XDD extension cable m XDD extension cable
SPARES
117
35
Diaphragm service kit
61
144
303
312,50
1
Inlet connection
2
Outlet connection
10
149 163
164
1
126 223
35
117
58
142
2
232
1
Inlet connection
2
ORDERING NUMBER
A50516000 A50506000 A50507000 A50508000
D39700835 D39700836 D39700837
The pump connector is a 15 pin DIN connector. These cables have 15 pin DIN connections on both ends and are suitable for connecting the pump to the BOC Edwards Turbo and Instrument Controller (TIC). 10
226
A74601983 A74601991
Factory set to 230 V
XDD1 1 2 5
162
149 22
2
ORDERING NUMBER
* Use suitable cable for your country. † Factory set to 230 V
2
0.80
22
PAGE 36
XDD1 100-200 V/200-230 V 50/60Hz*† XDD1 24 V
1.40
Outlet connection
Shop online at www.bocedwards.com
ORDERING NUMBER
A74601800