eta_07-0262-ag_030710-e

Page 1

Belgian Union for technical Approval in construction p/a Federal Public Service Economy, SMEs, Selfemployed and Energy WTC 3, 6th floor, Simon Bolivarlaan, 30 , B-1000 Brussel Tel: 0032 (0)2 277 81 76 Fax: 0032 (0)2 277 54 44 E-mail: dbgv.scas@economie.fgov.be. Website: www.ubatc.be

UBAtc Member of EOTA

EUROPEAN TECHNICAL APPROVAL

ETA-07/0262

Trade name:

FIRESTONE ULTRAPLY TPO

Holder of the approval:

Firestone Building Products Europe Ikaroslaan 75 B-1930 Zaventem Belgium

Website:

www.firestonebpe.be

Generic type and use of construction product(s):

Systems of mechanically fastened flexible roof waterproofing membranes

Validity

from:

2007-10-22

to:

2012-10-21

Manufacturing plant:

Wellford, South Carolina, USA

This European Technical Approval contains:

12 pages including 3 annexes which form an integral part of the document.

European Organisation for Technical Approvals Organisation Européenne pour l’Agrément Technique Europäische Organisation für Technische Zulassungen


ETA 07/0262 – FIRESTONE ULTRAPLY TPO

I LEGAL BASES AND GENERAL CONDITIONS 1. This European Technical Approval is issued by UBAtc in accordance with: − Council Directive 89/106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of Member States relating to construction products1, modified by Council Directive 93/68/EEC2 and Regulation (EC) N° 1882/2003 of the European Parliament and of the Council3; − Belgian law of 25 March 1996 concerning the adaptation of legislative and administrative provisions of Member States to the Construction Products Directive (89/106/EEC) for construction products4 and Belgian Royal Decree of 18 August 1998 concerning construction products5 − Common Procedural Rules for Requesting, Preparing and the Granting of European Technical Approvals set out in the Annex to Commission Decision 94/23/EC6; − Guideline 006 Systems of mechanically fastened flexible roof waterproofing membranes (2000) 2. The UBAtc is authorized to check whether the provisions of this European Technical Approval are met. Checking may take place in the manufacturing plant. Nevertheless, the responsibility for the conformity of the products to the European Technical Approval and for their fitness for the intended use remains with the holder of the European Technical Approval. 3. This European Technical Approval is not to be transferred to manufacturers or agents of manufacturers other than those indicated on page 1, or manufacturing plants other than those laid down in the context of this European Technical Approval. 4. This European Technical Approval may be withdrawn by UBAtc, in particular pursuant to information by the Commission according to Article 5(1) of Council Directive 89/106/EEC.

1

Official Journal of the European Communities N° L 40, 11.2.1989, p. 12 2 Official Journal of the European Communities N° L 220, 30.8.1993, p. 1 3 Official Journal of the European Union N° L 284, 31.10.2003, p. 1 4 Belgian Law Gazette, 21.05.1996 5 Belgian Law Gazette, 11.09.1998 6 Official Journal of the European Communities N° L 17, 20.1.1994, p. 34 2/12

5. Reproduction of this European Technical Approval including transmission by electronic means shall be in full. However, partial reproduction can be made with the written consent of UBAtc. In this case partial reproduction has to be designated as such. Texts and drawings of advertising brochures shall not contradict or misuse the European Technical Approval. 6. The European Technical Approval is issued by the approval body in its official languages. These versions correspond fully to the version circulated in EOTA. Translations into other languages have to be designated as such.


ETA 07/0262 – FIRESTONE ULTRAPLY TPO II SPECIFIC CONDITIONS OF THE EUROPEAN TECHNICAL APPROVAL 1. Definition of the product and intended use 1.1 Definition 1.1.1 General Firestone Ultraply TPO roofing kits are mechanically fastened roof waterproofing membranes, composed of single ply Firestone TPO roofing membranes, mechanically fastened to the structure with the following fasteners and plates: - SFS IR2 4,8xL fastener + SFS IR 40 x 80 mm plate, conform ETAG 006 (2000) - ISOTAK BS48 fasteners and Twin Peak Plus TPP-8040-60 plate in accordance with ETA 06/0170.

1.1.2 Roofing membrane The Firestone TPO membrane is a reinforced membrane manufactured with thermoplastic polyolefin (TPO) polymer, that contains (heat- and UV-) stabilisers and pigments. The membrane consists of two layers of polymer with a polyester fabric in between, and is produced by extrusion followed by lamination. The sheet is available in 2 thicknesses, 1,1 mm (0.045”) and 1,5 mm (0.060”) and can be white, light grey or tan in colour. The characteristics of the roofing sheets are given in table 1.

The fastener is in conformity with the specification of ETAG 006 (2000). ISOTAK BS 48 + TPP-8040-60 - ISOTAK BS 48: tempered carbon steel fastener SHE 1018, normal point, trumpet head and Torx25 countersunk hexagon head, with a diameter of 4,8 mm. - ISOTAK TPP 8040 Twin Peak Plus : plastic (polyamide) fastening plug of 78 x 44 mm with integrated sleeve Ø 13 mm and additional spikes on either side of the sleeve. The fastener is in conformity with the specification of the ETAG 006 (2000) and is part of the European Technical Approval ETA – 06/0170. The membrane and fasteners may be commercialised in separate transactions and the system is assembled on site. Fastener properties are given in annex B.

1.1.4 Ancillary products Ancillary products referred to in this ETA, as a part of installation provisions or in the framework of determining performances, are not covered by this ETA and cannot be CE-marked on the basis of it. Ancillary products as part of installation provisions: 1.1.4.1 Firestone Ultraply TPO Cut Edge Sealant

Firestone Ultraply TPO 1,1 1,5 1,22 1,71 30,5 1,52 – 2,43 – 3,05 White/grey/tan on light grey

Thickness (mm) -5 % + 10% Mass per unit area (kg/m²) ± 10 % Nominal length (m) Nominal width (m) Colour

Membrane properties are given in annex A. 1.1.3

Mechanical fastener and substrate

Mechanical fasteners for use in profiled steel deck which fall in the scope of the investigation done for this Technical Approval are: Manufacturer: SFS Intec Fastener IR2 4,8xL ISOTAK BS 48

Plate IR 82x40 TPP-8040-60

Composition of the fasteners: IR2 4,8xL + IR 82x40 - IR2: tempered carbon steel fastener, doublethread with a diameter of 4,8 mm, and a 8 mm hexagonal head. Durocoat corrosion protection. - IR: Steel plate of 40 mm x 82 mm with aluzinc protection.

Firestone UltraPly TPO Cut Edge Sealant is a polymer based sealant used to seal all cut edges of the UltraPly TPO membrane where the polyester reinforcement is exposed. Base Polymer: Synthetic Rubber Colours: White, Tan, Grey Solvents: Aromatic and Aliphatic Viscosity: 2,000 – 3,000 cps Specific Gravity: 0,952 1.1.4.2 Firestone Ultraply Bonding Adhesive Firestone UltraPly Bonding Adhesive is a solvent based contact adhesive designed specifically for bonding Firestone UltraPly TPO membranes to the upstands. Base: Polychloroprene and SBR rubbers Colour: Yellow Solvents: Acetone, Hexane, Toluene, Xylene Viscosity: 3,300-3,800 cps Specific Gravity: 0,7909-0,8868

3/12


ETA 07/0262 – FIRESTONE ULTRAPLY TPO 1.2 Intended use

progress file (2007) has been provided.

1.2.1

2.2.1 Mechanical resistance and stability (ER1)

General

Firestone Ultraply TPO membranes may be used on flat and sloped roofs. The supporting roof deck may exist of profiled steel deck, concrete, light weight concrete or a wooden based construction, which can be the direct substrate of the mechanically fastened roof waterproofing system. When insulation is the direct substrate, it shall be conform the requirements of § 4.2 of this ETA. The insulation is not a part of the kit. 1.2.2

Not relevant 2.2.2 Safety in case of Fire (ER2) 2.2.2.1 External fire performance Firestone Ultraply TPO membranes have been tested according to EN 1187 part 1, mechanically attached on different substrates and have been classified according to EN 13501-5 as follows:

Assumed working life

The assumed working life of the product for the intended use is 15 years7, provided that the assembled product is subject to appropriate use and maintenance, in accordance with paragraph 5.2 of this ETA.

2. Characteristics of product(s) and methods of verification 2.1 Evaluation of ancillary products For ancillary products referred to in this ETA specifically (by trade name), the composition of the product (if manufactured by the ETA holder) or its properties/characteristics (if supplied to the ETA holder) are laid down in the confidential ETA file held by the approval body. The ETA holder shall inform the approval body if any of this information is no longer correct.

Class BROOF(t1) is valid for the following end use conditions for the Firestone Ultraply TPO 045 membrane (1,1 mm): - roof pitch up to 20° - decks: - any profiled and non-perforated steel deck - any non-combustible continuous deck with a minimum thickness of 10 mm - insulation materials: - mineral wool (density 150 kg/m³) of 100 mm - faced PIR (density 34,9 kg/m³ - density foam 27,7 kg/m³) of 75 mm The Firestone Ultraply TPO 060 membrane (1,5 mm) is classified FROOF. 2.2.2.2 Reaction to fire The Firestone Ultraply TPO 045 and 060 membranes are classified “F” according to EN 13501-1. 2.2.3. Hygiene, Health and the Environment (ER3)

For ancillary products referred to in this ETA generally (by minimum requirements), compliance with these minimum requirements of products tested as part of test assemblies has been verified in the framework of approval testing. In the intended end use conditions, assemblies in which mechanically fastened roof waterproofing membranes are used, should meet all works related requirements 2.2 Characteristics and method Assessment of the fitness of the roof waterproofing for the intended use with regard to the essential requirements was performed following the Guideline for European Technical Approval of systems of mechanically fastened flexible roof waterproofing membranes (ETAG 006 – 2000). Where appropriate, additional information following the ETAG 006 7 The indications given as to the working life of the products cannot be interpreted as a guarantee given by the ETAholder or the approval body. It should only be regarded as a means for the specifiers to choose the appropriate product in relation to the expected, economically reasonable working life of the works. 4/12

2.2.3.1 Release of dangerous substances The systems of mechanically fastened flexible roof waterproofing membranes comply with all relevant European and national provisions8 applicable for the uses for which it is brought to the market. In addition to this ETA clause relating to dangerous substances, there may be other requirements applicable to the products falling within its scope (e.g. transposed European legislation and national laws, regulations and administrative provisions). In order to meet the provisions of the EU Construction Products Directive, these requirements need also to be complied with, when and where they apply. 2.2.3.2 Peel resistance of joints In accordance with EN 12316-2, the joints have a MLV for peel resistance of ≥ 100 N/50 mm

8

Known at the date of issuing.


ETA 07/0262 – FIRESTONE ULTRAPLY TPO 2.2.3.3 Shear resistance of joints

Membrane

In accordance with EN 12317-2, the joints have a MLV for shear resistance of ≥ 800 N/50 mm

2.2.4.2 Slipperiness No performance determined.

2.2.3.4 Tear resistance Fastener In accordance with EN 12310-2, the membranes have a MLV for tear resistance of ≥ 800 N (L) and 500 N (T).

2.2.4.3 Axial loading test See ETA 06/0170 and Annex B

2.2.3.5 Cold bending 2.2.4.4 Testing of unwinding of fastener In accordance with EN 495-5, the MLV for cold bending temperature of the membranes is -50°C.

See ETA 06/0170 and Annex B

2.2.3.6 Resistance to water pressure

2.2.4.5 Testing of mechanical resistance of sleeve

The membranes are watertight when tested in accordance with EN 1928.

See ETA 06/0170 and Annex B 2.2.5 Protection against noise (ER5)

2.2.3.7 Vapour permeability Not relevant. Regarding the water vapour permeability of the membranes, reference is made to tabulated values.

2.2.6 Energy economy and heat retention (ER6)

2.2.3.8 Tensile properties

Not relevant since the insulation is not part of the kit.

In accordance with EN 12311-2 the membranes have a declared tensile strength (MDV) of 800 N/50 mm (L/T) and a declared elongation at break (MDV) of 20% (L/T).

2.2.7 Aspects of durability and serviceability Membrane 2.2.7.1 Peel resistance of joints after long term exposure to heat

2.2.3.9 Static and impact loading The membranes have a MLV for resistance to static load in accordance with EN 12730 of 25 kg on both concrete and EPS and a MLV for resistance to impact load at 23°C in accordance with EN 12691:2001 of 10 mm on both concrete and EPS. 2.2.3.10 Dimensional stability In accordance with EN 1107, the membranes have a MLV for dimensional stability of 0,5%.

In accordance with EN 1296 and EN 12316-2, the heat welded joints of the membrane are resistant to heat ageing ( Δ ≤ 20 %). 2.2.7.2 Shear resistance of joints after long term exposure to heat In accordance with EN 1296 and EN 12317-2, the heat welded joints of the membrane are resistant to heat ageing ( Δ ≤ 20 %). 2.2.7.3 Resistance to cold bending/folding after long term exposure to UV

2.2.4 Safety in Use (ER4) System

In accordance with EN 1297 and EN 495-5, the membrane is resistant to UV ageing (Δ ≤ 5°C).

2.2.4.1 Wind uplift The systems of mechanically fastened flexible roof waterproofing membranes Firestone Ultraply TPO 045 and Firestone Ultraply TPO 060 have obtained the following admissible design loads for wind uplift in accordance with ETAG 006 on a steel deck: min. thickness 0,75 mm, S280 (EN 10147) or higher. Fastener IR2 4,8xL ISOTAK BS 48

Plate IR 82x40 TPP-8040-60

Wadm 850 N/fastener(°) 850 N/fastener(°)

(°) Higher value obtained was topped down by ETA holder

Fastener 2.2.7.4 Resistance to corrosion of metallic fasteners IR2 4,8xL + IR 82x40 The metallic fasteners and plates offer a corrosion resistance of 15 cycles according to EN-ISO 6988 and the interpretation of ETAG 006(2000). ISOTAK BS 48 The metallic fasteners and plates offer a corrosion 5/12


ETA 07/0262 – FIRESTONE ULTRAPLY TPO resistance of 15 cycles according to EN-ISO 6988 and the interpretation of ETAG 006 (2000) as per ETA-06/0170. 2.2.7.5 Mechanical resistance after heat ageing of plastic fasteners TPP 8040-60 The plastic fasteners with polypropylene and polyamide satisfy the aspects of durability according to ETAG 006 (2000) § 5.3.7.1 and § 5.3.7.2. as per ETA 06/0170.

3. Evaluation of Conformity and CE marking 3.1 Attestation of Conformity The system of attestation of conformity specified by the European Commission in mandate Construct 97/223 Annex 3 is system 2+ described in Council Directive (89/106/EEC) Annex III, 2(ii), first possibility and is detailed as follows: (a)

System (b) 2.2.7.6 Basic durability assessment Product performances confirm a working life of 15 years.

Tasks of the manufacturer - initial type-testing of the product - factory production control Tasks of the approved body - initial inspection of factory and of factory production control - continuous surveillance, assessment and approval of factory production control

3.2 Responsibilities 3.2.1 Tasks of the manufacturer 3.2.1.1 Initial Type Testing Approval tests have been conducted by the approval body or under its responsibility in accordance with section 5 of ETAG 006 (2000). The approval body has assessed the results of these tests in accordance with section 6 of ETAG 006, as part of the ETA issuing procedure. These tests should be used for the purposes of Initial Type Testing. This work should be taken over by the manufacturer for Declaration of Conformity purposes. 3.2.1.2 Factory production control The manufacturer shall exercise permanent internal control of production. All the elements, requirements and provisions adopted by the manufacturer shall be documented in a systematic manner in the form of written policies and procedures. This production control system shall ensure that the product is in conformity with the European Technical Approval (ETA). Manufacturers having an FPC system which complies with EN ISO 9000 and which addresses the requirements of an ETA are recognised as satisfying the FPC requirements of the Directive. 3.2.1.2.1 In-coming material When materials/products are delivered for incorporation into the production process, verification of conformity with specifications in the ETA takes place.

6/12


ETA 07/0262 – FIRESTONE ULTRAPLY TPO 3.2.1.2.2 Maintenance, equipment

calibration

of

testing

All testing equipment is being maintained, calibrated and/or checked against equipment or test specimens traceable to relevant international or nationally recognised reference test specimens (standards). The ETA-holder ensures that handling, preservation and storage of test equipment is such that its accuracy and fitness for purpose is maintained The calibration of all test equipment shall be repeated if any repair or failure occurs which could upset the calibration of the test equipment. 3.2.1.3 Other tasks of the ETA-holder The manufacturer is following the test plan as per EN 13956, the test method and threshold values have been laid down in the control plan, with is in the technical file laid down with UBAtc. 3.2.1.4 Declaration of Conformity When all the criteria of the Conformity assessment have been satisfied the manufacturer shall make a Declaration of Conformity. 3.2.2 Tasks of approved bodies

Once ITT (cf. 3.2.2.1) and the initial inspection of the FPC system (cf. 3.2.2.2) have been performed and if a favourable decision can be made on the basis of available information, the notified certification body shall issue an EC Certificate of conformity, permitting the ETA-holder to issue an EC Declaration of conformity, allowing CE Marking of the products. 3.3 CE marking 3.3.1 General The CE marking shall be affixed to the packaging and accompanying documents. In accordance with ETAG 006, the required information to accompany the CE symbol is: (a) name or identifying mark of the producer (b) number of notified body (c) last two digits of the year in which the marking was affixed (d) number of the ETA (to identify the characteristics of the mechanically fastened flexible roof waterproofing system and the characteristics where the “no performance determined” approach is used) (e) Number of ETAG (f) Number of FPC certificate. (g) Product identification

3.2.2.1 Initial type testing The approval tests have been conducted by the approval body in accordance with ETAG 006 (2000), and the approval body has assessed the results of these tests in accordance with chapter 6 of that ETAG, as part of the ETA issuing procedure. These tests shall be used for the purposes of Initial Type Testing. Where appropriate, additional information following the ETAG 006 progress file (2007) has been provided. 3.2.2.2 Assessment of the factory production control system - initial inspection and continuous surveillance Assessment of the factory production control system is the responsibility of the approved body. An assessment shall be carried out of the production unit to demonstrate that the factory production control is in conformity with the ETA and any subsidiary information. This assessment shall be based on an initial inspection of the factory. The relevant production unit has been specified in the ETA.

3.3.2 Example of CE marking "CE"-symbol yyyy Firestone Building Products Europe Ikaroslaan 75 B-1930 Zaventem Belgium 04 07 yyyy-CPD-XXXX ETA N° XX/XXXX ETAG 006 Ultraply TPO

Number of Notified Body Name of the ETA-holder + Code of the manufacturing plant Two last digits of year of affixing CE marking Number of FPC certificate of conformity ETA Number ETAG Reference Product identification

3.4 Other marking and/or information Each membrane is marked on the package with product name and traceability code, thickness and dimensions of the membrane.

Subsequently continuous surveillance of factory production control is necessary to ensure continuing conformity with the ETA. It is recommended that Surveillance inspections are to be conducted at least twice a year. However, if the results of the first inspection are satisfactory, the inspection interval may be reduced to once a year. 3.2.2.3 Certification 7/12


ETA 07/0262 – FIRESTONE ULTRAPLY TPO 4. Assumptions under which the fitness of the product(s) for the intended use was favourably assessed 4.1 Manufacturing The European technical approval is issued for the product on the basis of agreed data/information, deposited with the approval body, which identifies the product that has been assessed and judged. Changes to the product or production process, which could result in this deposited data/information being incorrect, should be notified to the approval body before the changes are introduced. The approval body will decide whether or not such changes affect the ETA and consequently the validity of the CE marking on the basis of the ETA and if so whether further assessment or alterations to the ETA, shall be necessary. 4.2 Installation

Figure 1: Standard overlap with mechanical attachment

Transversal joints (Figure 2) and/or joints without mechanical fasteners in the overlap shall be executed with a minimum overlap of 100 mm and hot air welded over 40 mm (automatic weld) or 50 mm (manual weld), calculated from the edge of the upper sheet of the overlap. The weld shall be executed and pressured with a pressure roller. Any exposed visible cut edges shall be covered with Ultraply TPO Cut Edge Sealant.

4.2.1 General The system of mechanically fastened roof waterproofing membranes Firestone Ultraply TPO, should be installed in line with the manufacturers installation guidelines and national provisions of good practice. 4.2.1.1 Supporting structure Firestone Ultraply TPO membranes may be used on flat and sloped roofs. The supporting roof deck may exist of profiled steel deck, concrete, light weight concrete or a wooden based construction, which can be the direct substrate of the mechanically fastened roof waterproofing system. The supporting deck needs to be structurally sound and in conformity with national provisions. When insulation is the direct substrate, it shall be verified that the material has sufficient compressive strength (10% compression ≥ 50) and point load behaviour (PL(5)600 ≥ 600) taking into account the accessibility of the roof (as per national provisions). The insulation material must be CE marked in accordance with the relevant harmonised European standard. 4.2.1.2 Joints Figure 1 shows the standard overlap design for the longitudinal joints of the mechanically fastened Firestone Ultraply TPO roofing membrane. The sheets shall be positioned with a minimum overlap of 150 mm and the overlap shall be hot air welded over at least 40 mm by automatic welding tools or over at least 50 mm by manual welding tools, calculated from the edge of the upper sheet of the overlap.

8/12

Figure 2: Standard overlap without mechanical attachment

4.2.1.3 Mechanical fasteners The fasteners shall be installed within the joint overlap in accordance with the principles given in 4.2.1.2. The length of the fasteners shall be determined to ensure that the fastener will be protruding sufficiently through the profiled steel deck as required by national provisions. The number of fasteners shall be determined according to national legislation for every applicable roof zone (centre, corner, edge) by dividing the acting design wind load by the admissible design wind load per fastener Wadm: Fastener IR2 4,8xL ISOTAK BS 48

Plate IR 82x40 TPP-8040-60

Wadm 850 N/fastener(°) 850 N/fastener(°)

(°) Higher value obtained was topped down by ETA holder

The membrane width and fastener spacing shall then be determined to provide for at least the number of fasteners required.


ETA 07/0262 – FIRESTONE ULTRAPLY TPO 4.2.1.4 Base tie-in and upstand details

5. Recommendations

The membrane must be attached mechanically over the entire perimeter and around penetrations. The base tie-in shall be executed by mechanically attaching the membrane either in the plane of the roof or in the upstand with appropriate fasteners every 300 mm o.c. The upstands are further finished with a separate strip of Ultraply TPO membrane which is fully adhered with Ultraply Bonding Adhesive and/or mechanically attached according to the guidelines of the manufacturer. On top of the upstand, the membrane is mechanically attached and finished with an applicable detail.

5.1 Recommendations on packaging, transport and storage The Firestone Ultraply TPO membranes shall be stored flat on a clean, smooth and dry substrate, without sharp protrusions and protected against the influences of bad weather. The membranes must be kept away from any source of heat, sparks, flames,‌ The fasteners shall be stored in dry, ventilated premises and protected against direct sunlight

5.2 Recommendations on use, maintenance and repair It is the responsibility of the manufacturer to ensure that proper information for the use of the Firestone Ultraply TPO membranes and specified fasteners are available at each delivery, including general guidance on the basis of this ETA. The assessment of the fitness for use is based on the assumption that a normal maintenance of the system is performed. Repairs in the roofing system shall be executed with similar materials as used during the installation. The repairs shall be done with care and according to the guidelines of the manufacturer.

Figure 3: Base tie-in detail

9/12


ETA 07/0262 – FIRESTONE ULTRAPLY TPO Annex A: Membrane characteristics of the Firestone Ultraply TPO membranes.

EN 13501-1

Declaration 045 Euroclass F

060 Euroclass F

EN 12316-2 EN 1296 + EN 12316-2

≥100 Δ≤20%

≥100 Δ≤20%

EN 12317-2 EN 1296 + EN 12317-2 EN 12310-2

≥800 Δ≤20% ≥800 / 500

≥800 Δ≤20% ≥800 / 500

EN 495-5 EN 1297 + EN 495-5 EN 1928 EN 1931

≤-50 ≤-50 ≤-50 ≤-50 Pass Pass Tabulated values

EN 12311-2 EN 12311-2 EN 12730 EN 12691 EN 1107-2

800/800 20/20 ≥25 ≤ 10 ≤0,5

Characteristic

Standard

Reaction to fire Peel resistance joints (L,T) (N/50 mm) -initial -after heat ageing Shear resistance joints (N/50 mm) -initial -after heat ageing Resistance to tear (N) (L/T) Resistance to cold bending (°C) -initial - after UV ageing Resistance to water pressure Water vapour permeability Tensile properties (L,T) -max. strength (N/50 mm) -elongation at max. strength (%) Resistance to static loading (kg) Resistance to impact (mm) Dimensional stability (%)

10/12

800/800 20/20 ≥ 25 ≤10 ≤0,5


ETA 07/0262 – FIRESTONE ULTRAPLY TPO Annex B: Characteristics of the fasteners used with the Firestone Ultraply TPO membranes. Fastener + plate Steel substrate IR 4,8 x L + IR 82 x 40 (1) ISOTAK BS 48 + TPP 8040 (2) (1) (2)

Axial loading (N)

Resistance to unwinding

Mechanical resistance of the plastic fastener

Corrosion resistance

1450 (declared mean) 1280 (5% fractile) 1200 (declared mean) 1020 (5% fractile)

OK

Not relevant

OK

OK

Pass

OK

Steel sheet, galvanised, min S280 according to EN 10147, 0,75 mm Steel sheet, galvanised, min S280 according to EN 10147, 0,7 mm

11/12


ETA 07/0262 – FIRESTONE ULTRAPLY TPO ANNEX C: References Reference number ETAG 006 (edition 2000) Document title Systems of mechanically fastened flexible roof waterproofing membranes Reference number ETAG 006 progress file 2007 Document title Systems of mechanically fastened flexible roof waterproofing membranes Reference number EN 495-5, Document title Flexible sheets for waterproofing — Determination of foldability at low temperature — Part 5: Plastic and rubber sheets for roof waterproofing Reference number EN 1107-2, Document title Flexible sheets for waterproofing — Determination of dimensional stability — Part 2: Plastic and rubber sheets for roof waterproofing Reference number EN 1297:2004, Document title Flexible sheets for waterproofing Bitumen, plastic and rubber sheets for roof waterproofing - Method of artificial ageing by long term exposure to the combination of UV radiation, elevated temperature and water Reference number EN 1548, Document title Flexible sheets for waterproofing — Method for exposure to bitumen — Plastic and rubber sheets for roof waterproofing Reference number EN 1849-2, Document title Flexible sheets for waterproofing — Determination of thickness and mass per unit area — Part 2: Plastic and rubber sheets for roof waterproofing Reference number EN 1928, Document title Flexible sheets for waterproofing — Bitumen, plastic and rubber sheets for roof waterproofing — Determination of water tightness Reference number EN 1931, Document title Flexible sheets for waterproofing — Bitumen, plastic and rubber sheets for roof waterproofing —Determination of water vapour transmission properties Reference number EN 12310-2, Document title Flexible sheets for waterproofing — Determination of resistance to tearing — Part 2: Plastic and rubber sheets for roof waterproofing Reference number EN 12311-2, Document title Flexible sheets for waterproofing — Determination of tensile properties — Part 2: Plastic and rubber sheets for roof waterproofing

12/12

Reference number EN 12316-2, Document title Flexible sheets for waterproofing — Determination of peel resistance of joints — Part 2: Plastic and rubber sheets for roof waterproofing Reference number EN 12317-2, Document title Flexible sheets for waterproofing Determination of the shear resistance of joints Part 2: Plastic and rubber sheets for roof waterproofing Reference number EN 12691 Document title Flexible sheets for waterproofing — Bitumen, plastic and rubber sheets for roof waterproofing — Determination of resistance to impact Reference number EN 12730, Document title Flexible sheets for waterproofing — Bitumen, plastic and rubber sheets for roof waterproofing — Determination of resistance to static loading Reference number EN 13501-1:2002, Document title Fire classification of construction products and building elements — Part 1: Classification using test data from reaction to fire tests Reference number EN 13501-5, Document title Fire classification of construction products and building elements — Part 5: Classification using results from external fire exposure to roof tests Reference number EN ISO 11925-2, Document title Reaction to fire tests — Ignitability of building products subjected to direct impingement of flame — Part 2: Single-flame source test (ISO 11925-2:2002)